ML11214A178
| ML11214A178 | |
| Person / Time | |
|---|---|
| Site: | West Valley Demonstration Project, P00M-032 |
| Issue date: | 03/10/2011 |
| From: | AMEC Geomatrix, URS Corp |
| To: | NRC/FSME |
| References | |
| 13302.003.0 | |
| Download: ML11214A178 (1) | |
Text
Figure 8 1400.00 1390.00 1380.00 1370.00 1360.00 1340.00 1350.00 Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 Station 8 Station 9 Station 10 Station 11 Station 12 Well Cluster Well Cluster Well Installed in PTW Only Well Installed in PTW Only Well Installed in PTW Only Well Installed in PTW Only Well Installed in PTW Only Well Installed in PTW Only Well Installed in PTW Only PTW-E PTW-TH1 PTW-TH2 PTW-TH3 PTW-TH4 PTW-TH5 PERFORMANCE MONITORING NETWORK As Built PTW Performance Monitoring Plan West Valley Environmental Services, LLC West Valley, New York Performance Monitoring Network (Cross Section View)
Scale 1 inch = 60 feet Vertical Exageration (Cross Section): 4x 0
50 100 25 Feet A
A' J:\\GIS\\ArcMap\\North Plateau\\PTW_PMP_Amec_2010\\PTW_PMP_Fig8a_PMP_Figure8a_AsBuilt_20110310.mxd, 03/10/2011 afs/skw Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 Station 8 Station 9 Station 10 Station 11 Station 12 A
A' MW-5 MW-18-SWS PTW-E PTW-S1A PTW-TH5 PTW-S9A PTW-S9C PTW-S8C PTW-S8A PTW-TH4 PTW-TH3 PTW-TH2 PTW-S2C PTW-S2A PTW-S1C PTW-S12C PTW-S11A PTW-S10C PTW-S10A PTW-S7C-S,D PTW-S7A-S,D PTW-S6A-S,D PTW-S5C-S,D PTW-S4C-S,D PTW-S4A-S,D PTW-S3C-S,D PTW-S3A-S,D MW-PTW-11R PTW-W PTW-S9B PTW-S8B PTW-S2B PTW-TH1 PTW-S1B PTW-S12B PTW-S12A PTW-S11B PTW-S11C PTW-S10B PTW-S7B-S,D PTW-S6C-S,D PTW-S6B-S,D PTW-S5B-S,D PTW-S5A-S,D PTW-S4B-S,D PTW-S3B-S,D PTW-C2-TBU1,2,3,4 PTW-C1-TBU1,2,3,4 PTW-W PTW-E MW-5 MW-4 MW-2 WP22 WP12 WP10 WP02 MW-25 MW-24 MW-21 MWPTW-3-S MWPTW-3-D MW-18-TBU 106+00 105+00 108+00 107+00 104+00 103+00 102+00 101+00 100+00 100 1000 10000 100 1000 1000 100 1000 10000 100 Performance Monitoring Network (Plan View)
Legend A
Single PTW Well A
Single PTW Well (till depth)
A PTW Well Couplet A
PTW Well Cluster A
Full Network Well PTW Alignment March 2009 Sr-90 Contours PTW Installation Platform Slackwater Sequence Pilot PTW Structure Roads
")")")")")")")") Well Screen (B's)
PTW Trench Bottom February, 2010 Water Level A
A'
(
( Cross Section Geologic Unit SWS FILL TBU TILL 103+60 104+00 104+40 100+00 100+40 100+80 101+20 101+60 102+00 102+40 102+80 103+20 104+80 105+20 105+60 106+00 106+40 106+80 107+20 107+60 108+00 108+40 108+80 Original Date: 05/28/10 Reissued: 03/10/11 By: ADF By: AFS / SKW Project No. 13302.003.0