ML111750171

From kanterella
Jump to navigation Jump to search
Initial Exam 2011-301 Final RO Written Exam with References
ML111750171
Person / Time
Site: Farley  
(NPF-002, NPF-008)
Issue date: 06/21/2011
From:
NRC/RGN-II
To:
Southern Nuclear Operating Co
References
50-348/11-301, 50-364/11-301, ES-401-7
Download: ML111750171 (80)


Text

{{#Wiki_filter:ES-401-7 Site-Specific RO Written Examination Cover Sheet U.S. Nuclear Regulatory Commission Site-Specific RO Written Examination Applicant Information Name: Date: 5/2412011 Facility/Unit: FARLEY Units I & 2 Region: I 0 ii II iii 0 iv 0 Reactor Type: W Il CE 0 BW 0 GE 0 Start Time: Finish Time: Instructions Use the answer sheets provided to document your answers. Staple this cover sheet on top of the answer sheets. To pass the examination, you must achieve a final grade of at least 80.00 percent. Examination papers will be collected 6 hours after the examination begins Applicant Certification All work done on this examination is my own. I have neither given nor received aid. Applicants Signature Results Examination Value 75 Points Applicants Score Points Applicants Grade Percent

1. Unit 2 is at 55°k power with thefoDowing conditions:

2A BAT is on service, 2B BAT is on standby. At 10:00: Control Rods are stepping out in AUTO and cannot be stopped. The Reactor cannot be tripped and FRP-S.1, Response to Nuclear Power Generation! ATWT, has been entered. An emergency boration is in progress per FRP-S.1, with the 2A BAT pump running. At 10:05: The 2A BAT pump trips. Which one of the following completes the statements below? Verify2BBATpump (1) Per FRP-S.1, minimum boration flow is required to be greater than (2) gpm. (1) (2) A. autostarts 30 B. is manually started 30 C. autostarts 40 D. is manually started 40 HLT34 RO NRC exam 5/24/2011 Page 1 of 75

2. Given thefallowing conditions on Unit 2:

Reactor power is 90%. Rod Control is in AUTO. Control Bank D rods are at 200 steps. Which one of the following describes how control rods will respond when N-44, PR NI, fails LOW quickly with no operator actions or automatic reactor trips? A. Rods step out until Tavg/Tref mismatch causes them to step back in. B. Rods step in until Tavg/Tref mismatch causes them to step back out. C. Rods step out and stay out. D. Rods step in and stay jj. HLT34 RO NRC exam 5/24/2011 Page 2of75

3. Unit 2 is in Mode 4 with the following conditions At 10:00:

20 RCP was started, but tripped due to over-current during the start attempt. At 10:45: The Shift Manager directs 4160V Bus Voltage raised and the 20 RCP restarted. The following MCB parameters are observed: 20 RCP #1 SEAL PRESSURE is 240 psid. 20 RCP SHAFT SEAL FLOW is 6.5 gpm. VCT PRESS is 16.5 psig. Which one of the following parameters, per SOP-i.1, Reactor Coolant System, will prevent the operator from starting the 20 Reactor Coolant Pump? A. 1i1 Seal DP B. VCT pressure C. Seal injection flow D. Insufficient idle time between start attempts HLT34 RD NRC exam 5/24/2011 Page 3 of 75

4. Unit 1 is at I 00% power with the following conditions:

Pressurizer level is stable and on program. Seal injection flow is in the green band. RCP #1 Seal leakoff flow is normal. Letdown is in service with HV-8I49C, LTDN ORIF ISO 60 GPM, open. All control systems are in AUTO. Which one of the following sets of indications for CVCS Charging and Letdown flow represent steady-state conditions with no RCS leakage? CHG FLOW Fl-I 22A (qm) LTDN HX OUTLET FLOW Fl-I 50 (cinm) A. 60 75 B. 75 75 C. 60 84 D. 75 60 HLT34 RO NRC exam 5/24/2011 Page 4 of 75

5. Unit 1 has experienced, a Safety Injections Which one of the following completes the statement below?

RCP #1 Seal Leakoff will be directed to the A. Reactor Coolant Drain Tank B. Containment Sump C. Pressurizer Relief Tank D. Volume Control Tank HLT34 RO NRC exam 5/24/2011 Page 5 of 75

6 Unit I is in Mode-5 with the following conditions: At 1000: RCS is in solid plant conditions. A Train RHR is in service in the cooldown mode. Low Pressure Letdown is aligned to A Train. Charging and Letdown flows are balanced. RCS pressure is stable at 250 psig. PK-145, LP LTDN PRESS controller, is in AUTO. At 1010: A crud burst causes the RCS Filter to immediately clog. Which one of the following completes the statement below? RCS pressure will A. rise until RHR suction reliefs lift B. rise until the RHR loop suction isolation valves go closed C. lower and the VCT will divert to the RHTs D. lower and total Seal Injection flow will decrease HLT34 RO NRC exam 5/24/2011 Page 6 of 75

7. Unit 1 isat 100% power with the following conditions:

I B Charging pump is aligned to B Train. IC Charging pump is Tagged Out. At 1000: IF 4I60V Bus is de-energized and remains de-energized. Which one of the following combinations lists the ECCS pumps that have power available? Charging um with power RHR pump with power A. IA 1A B. 1A lB C. lB IA D. lB lB HLT34 RO NRC exam 5/24/2011 Page 7 of 75

8. Unit 1 is at 100%. power with the fol[owing conditions:

HA5, PRZR PORV TEMP HI, is in alarm. Pressurizer pressure is 2225 psig and slowly going down. PRT pressure is slowly rising. Both PORVs indicate closed. Which one of the following completes the statements below? TI-463, PORV tailpipe temperature, will increase to (1) P 1-472, PRT PRESS, will reach a maximum pressure of (2) (1) (2) A. between 220 and 340°F 100 psig B. greater than 600°F 100 psig C. greater than 600° F 75 psig D. between 220 and 340° F 75 psig HLT34 RO NRC exam 5/24/2011 Page 8 of 75

9. Unit I is in Mode 3 with the following conditions:

IA RHR pump is running for a boron sample. A and B Train CCW are in operation. Normal Letdown is in service with 75 gpm flow. Excess Letdown is in service in preparation for a Tag Out of the Normal Letdown line. Which one of the following is the effect of a loss of Instrument Air to individual CCW components? Alossofairto (1) ,would require (2) A.

1) TCV-3083, LTDN HX CCW TEMP CONTROLLER
2) isolating Letdown per DEl, LTDN TO DEMIN DIVERTED-TEMP HI B.
1) HV-3404A, RHR PUMP IA SEAL HX CCW PRESS REG
2) securing 1A RHR pump per CGI, IA RHR PUMP CCW FLOW LO C. 1) HV-3095, CCW TO EXCESS LTDN/RCDT HXS
2) isolating Excess Letdown per CHI, EXC LTDN HX OUTLET TEMP HI D. 1) RCV-3028, CCW SURGE TANK AIR VENT
2) closing RCV-3028 with the manual jack per SOP-23.O, Component Cooling Water System HLT34 RO NRC exam 5/24/2011 Page 9 of 75

10 Unit 1 has experienced a small break LOCA with the following conditions: RCS pressure is 2100 psig. CETCs are 750°F. All RCPs are stopped. FI-943, A TRAIN HHSI FLOW, indicates 0 gpm. FI-940, HHSI B TRAIN RECIRC FLOW, indicates 0 gpm. Which one of the following actions is required as the primary mitigation strategy per the applicable Functional Restoration Procedure? A. StartaRCP. B. Establish HHSI flow. C. Perform a max rate cooldown. D. Reduce RCS pressure by opening one PORV. HLT34 RO NRC exam 5/24/2011 Page 10 of 75

11. Unit I is at 100% power with the following conditions; HV-8145, RCS PRZR AUX SPRAY valve, has just started leaking by the seat atlogpm.

HCI, PRZR PRESS HI-LO, is in alarm. Which one of the following completes the statement below? Indication on Fl-122A, CHG FLOW, will initially (1) Demand on PK-444A, PRZR PRESS REFERENCE controller, will (2) (1) (2) A. increase increase B. increase decrease C. decrease increase D. decrease decrease HLT34 RO NRC exam 5/24/2011 Page 11 of 75

I2 Unit 1 is at 100% power with the following conditions: At 10:00: I B Charging pump is aligned to B Train. 1A Charging pump is running. At 10:10: Pressurizer level is falling. VCT level is rising. DDI, RCP SEAL INJ FLOW LO, alarm is LIT. DEl, REGEN HX LTDN FLOW DISCH TEMP HI, alarm is LIT. EA2, CHG HDR FLOW Hl-LO, alarm is LIT. Which one of the following events has occurred? A. An RCS piping break has occurred causing an Auto Roll-over to the RWST. B. PCV-145, LP LTDN Pressure Control Valve, has failed open. C. FCV-122, CHG Flow control valve, has failed closed. D. 1A Charging pump has tripped. HLT34 RO NRC exam 5/24/2011 Page 12 of 75

1 3 Unit 1 has ha a Reactor TriR and Safcty Injection actuation with th fo[lowirig conditions: A Large Break LOCA has occurred. Containment pressure has reached 29 psig. EEP-0, Reactor Trip or Safety Injection, is in progress. RCS pressure is 200 psig and dropping. Which one of the following describes the reason for securing RCPs under the above conditions? A. To delay two-phase flow in the RCS. B. To prevent overheating RCP motor bearings. C. To prevent a deeper and longer core uncovery later in the event. D. To avoid the possibility of RCP motor overspeed and flywheel fracture. HLT34 RO NRC exam 5/24/2011 Page 13 of 75

14. Which one-of the following completes the statements below?

The minimum coincidence (fewest number of channels or input signals) required to initiate an Intermediate Range High Flux Reactor Trip is (1) The minimum coincidence (number of Throttle Valves closed) to initiate a Reactor Trip from Turbine Trip is (2) (1) (2) loutof2 3outof4 3outof4 A. B. C. D. 2 outof2 1 outof2 2 out of 2 4 outof4 4 outof4 HLT34 RO NRC exam 5/24/201 1 Page 14 of 75

15. Unit 1 is a! 100% power with the followthg conditions:

At 10:00: PT-950, CTMT PRESS, has failed HIGH. The appropriate Tech Spec actions of T.S. 3.3.2, Engineered Safety Feature Actuation System (ESFAS) Instrumentation, have been completed. SPRAY ACTUATION BYPASS CH I TEST light is illuminated on the BYPASS & PERMISSVE panel. At 10:30: PT-953, CTMT PRESS, fails HIGH. Which one of the following automatic actuations, if any, will occur? A. No automatic actuations B. Safety Injection ONLY C. Safety Injection and MSIV isolation ONLY D. Safety Injection, MSIV isolation, Phase B and Ctmt Spray actuation ONLY HLT34 RO NRC exam 5/24/2011 Page 15 of 75

16. Unit 1 is at 25% power with the foowing conditions:

IC RCP trips. Which one of the following completes the statements below? IC Steam Generator narrow range level will (1) After IC RCP stops, IC Loop delta T indication will be (2) than IA and lB Loop delta T indications. (1) (2) A. swell higher B. swell lower C. shrink higher D. shrink lower HLT34 RO NRC exam 5/24/2011 Page 16of75

.17.. Unit 1 tripped from 75% power with the following conditions: N-35, Intermediate Range NI, is overcompensated. Which one of the following completes the statements below? N-35 will indicate (1) than actual power. The Source Range NIs will energize as soon as (2) , Intermediate Range NI, reaches the P-6 setpoint. (1) (2) A. lower N-35 B. lower N-36 C. higher N-35 D. higher N-36 HLT34 RD NRC exam 5/24/2011 Page 17 of 75

18. Unit I is at 1 Q0% power with th following condition An LOSP occurs and I B Diesel Generator trips.

Containment pressure is 34 psig due to a steam line break. BAI, 1A CTMT CLR FAN FAULT, comes into alarm due to a trip of the IA Containment Cooler. Which one of the following completes the statements below? The (1) CTMT CLR FAN is required to be started per EEP-O, Reactor Trip or Safety Injection. After the fan is started, Containment Pressure and Temperature (2) exceed design limits. (1) (2) A. 1C WILL B. lB WILL C. IC will NOT D. lB will NOT HLT34 RO NRC exam 5/24/2011 Page 18 of 75

19 Unit 1 is at 100% power with the following conditions: At 10:00: All containment fan coolers are operating in FAST speed. At 10:05: A steam leak occurs inside Containment. An automatic SI has occurred. Which one of the following describes the expected operation of the Containment Coolers? The Containment Coolers will be operating in (1) speed. The Containment Cooler discharge dropout plate opens when Containment (2) (1) (2) A. FAST pressure exceeds 4 psig B. SLOW pressure exceeds 4 psig C. FAST temperature exceeds 135°F D. SLOW temperature exceeds 135°F HLT34 RO NRC exam 5/24/2011 Page 19of75

I

20. The following conditions exist on Unit 1:

Mode 6. The RCS level is at midloop. Both RHR pumps are in operation. Low Pressure Letdown is in service on A Train. At 10:00: The IA RHR pump is in the following configuration: HIK-603A, 1A RHR HX DISCH VLV, is 0%. FK-605A, IA RHR HX BYP FLOW, is in manual with 75% demand. The I B RHR pump is in the following configuration: HIK-603B, lB RHR HX DISCH VLV, is 50%. FK-605B, I B RHR HX BYP FLOW, is in manual with 25% demand. At 10:05: IA RHR pump trips. Which one of the following completes the statement below? RCS level will (1) , and RCS temperature will (2) (1) (2) A. increase increase B. increase remain the same C. remain the same remain the same D. remain the same increase HLT34 RO NRC exam 5/24/2011 Page 20 of 75

21. UnLt I is at 75% power with the-following cond[tions:

Automatic control of TK-144, LTDN HX OUTLET TEMP, has failed. Letdown temperature is 150°F and rising. Which one of the following completes the statements below? The alarm expected for this condition is (I) The appropriate ARP will direct the operator to place TK-144 in MANUAL and (2) controller demand. (1) (2) A. DF1, LTDN TO DEMIN DIVERTED-TEMP HI raise B. DEl, REGEN HX LTDN FLOW DISCH TEMP HI raise C. DF1, LTDN TO DEMIN DIVERTED-TEMP HI lower D. DEl, REGEN HX LTDN FLOW DISCH TEMP HI lower HLT34 RO NRC exam 5/24/2011 Page 21 of 75

22. Unit I trippecLfrorn IOG% power with the following coniitions Safety Injection is in progress due to a Large Break LOCA.

Containment Spray has actuated. The following MCB annunciators are in alarm: CH4, RWST LVL A TRN LO-LO CH5, RWST LVL B TRN LO-LO Which one of the following completes the statements below? The setpoint for the RWST LO-LO alarms is (1) The operator is required to (2) using ESP-1.3, Transfer to Cold Leg Recirculation. (1) (2) A. 4 6 verify the CS sump suction MOVs automatically opened B. 4 6 open the CS sump suction MOVs C. 12 6 verify the RHR sump suction MOVs automatically opened D. 12 6 open the RHR sump suction MOVs HLT34 RO NRC exam 5/24/2011 Page 22 of 75

21 Which one of the following completes the statement below? The Containment Spray System reduces radioactive iodine in the Containment atmosphere during a LOCA by spraying water from the (1) at a pH of approximately (2) (1) (2) A. containment sump 4.5 B. RWST 7.5 C. containment sump 7.5 D. RWST 4.5 HLT34 RO NRC exam 5/24/2011 Page 23 of 75

24. Unit I is at 75% power wfth the. following conditions:

PK-444A, PRZR PRESS REFERENCE controller, is failed such that it senses a constant input pressure equivalent to 2219 psig. Which one of the following describes the automatic response of the Pressurizer Pressure Control system? A. PCV-445A, PRZR PORV, will cycle to control pressure. B. The variable heaters will cycle on and off at a higher setpoint. C. The spray valves will open to control pressure at a higher value. D. PCV-444B, PRZR PORV, will open and remain open until 2000 psig. HLT34 RO NRC exam 5/24/2011 Page 24 of 75

2.5. Unit 1 has lust Lost power to 600V Motor Control Center (MCC) IA. Which one of the following components will NOT have power? A. 1A Spent Fuel Pool pump B. 1A Containment Cooler Fan - Fast speed C. IA Post LOCA Hydrogen Recombiner D. MOV-8808A, IA Accumulator Discharge Isolation Valve HLT34 RO NRC exam 5/24/2011 Page 25 of 75

26. Given the follQwing conditions on Unit 1:

RCS pressure is 2350 psig. All SG pressures are 1035 psig. The reactor is NOT tripped. The crew is currently in FRP-S. 1, Response to Nuclear Power Generation/ATWT, performing the step, Check pressurizer pressure LESS THAN 2335 psig. Which one of the following completes the statements below per FRP-S.1? Open PRZR PORVs and PRZR PORV ISO valves and lower RCS pressure to (1) The reason for the pressure reduction is to (2) increase charging flow into the RCS reduce the differential pressure between the SGs and the RCS increase charging flow into the RCS reduce the differential pressure between the SGs and the RCS (2) (1) A. 2235 psig B. 2235 psig C. 2135 psig D. 2135 psig HLT34 RO NRC exam 5/24/20 1 1 Page 26 of 75

27. Which one of the. foUowin describes the Fuel Transfer Systems Pit..Crane Interlock and the reason for the interlock?

A. Prevents the SEP lifting frame from being lowered while the SEP bridge crane is in the Transfer Canal area, to prevent damage to a fuel assembly. B. Prevents movement of the SEP Bridge Crane when the lifting frame is, to prevent damage to the SFP Bridge Crane Hoist. C. Prevents the SFP lifting frame from being raised while the SEP bridge crane is in the Transfer Canal area, to prevent damage to the lifting frame. D. Prevents operation of the SEP Bridge Crane hoist when the lifting frame is down, to prevent bumping a fuel assembly when the frame is raised. HLT34 RO NRC exam 5/24/20 1 1 Page 27 of 75

28. The following conditions exist on Unit 1:

AOP-2.0, Steam Generator Tube Leak, is in progress. The Control Room crew is preparing for an RCS cooldown. The affected SG pressure is 980 psig. Desired subcooling is 30-32°F.

1) Using steam tables, which one of the following is the temperature at which the RCS cooldown is required to be stopped?
2) Per AOP-2.0, what temperature indication is used?

Reference Provided (1) (2) A. 513°F Core exit T/C monitor B. 544° F Core exit T/C monitor C. 513°F RCS Hot Leg Temperature D. 544°F RCS Hot Leg Temperature HLT34 RO NRC exam 5/24/2011 Page 28 of 75

29. Unit 1 is shutdown with the following coriditions At 10:00:

An SI was initiated due to a Small Break LOCA. ESP-I.2, Post LOCA Cooldown and Depressurization, is in progress. Normal charging has been established. All SG narrow range levels are 40% and stable. At 10:15: IA SG narrow range level is 48% and going up with no AFW flow to the SG. I B and 1 C SG narrow range levels are 40% and stable. Pressurizer level is 20% and trending down with maximum charging flow. Which one of the following completes the statement below? The foldout page of ESP-I.2 requires the crew to establish HHSI flow and A. remain in ESP-I.2, Post LOCA Cooldown and Depressurization. B. re-enter EEP-0, Reactor Trip or Safety Injection. C. go to EEP-1, Loss of Reactor or Secondary Coolant. D. go to EEP-3, Steam Generator Tube Rupture. HLT34 RO NRC exam 5/24/2011 Page 29 of 75

30. Unit 2 is performing the i.nital heatup of the RCS following a Refueling-outage, with th following conditions:

RCS temperature is 480°F. All MSIVs are closed. The Unit Operator is preparing to open the MSIVs per SOP-I 7.0, Main and Reheat Steam. ALL MSIV Bypass valves are open. The steam dumps are aligned in the STM PRESS mode per SOP-I 8.0, Steam Dump System. All required testing and maintenance activities have been completed. Which one of the following completes the statements below?

1) When A steam line MSIVs are opened, A MSIV Bypass valves will (1)
2) When opening MSIVs, Main Steam header pressure should be monitored closely to prevent a Safety Injection due to i2)

(1) (2) A. be manually closed Low Steam Line pressure B. be manually closed Steam Line Differential pressure C. automatically close Low Steam Line pressure D. automatically close Steam Line Differential pressure HLT34 RO NRC exam 5/24/2011 Page 30 of 75

3t Unit 2 is at 12% power with the following conditions: At 10:00: Tavg is 550°F and stable. Steam Dumps are in the STM PRESS mode. PK-464, STM HDR PRESS controller, is in AUTO. At 10:05: PT-464, STM HDR PRESS, fails HIGH. Which one of the following completes the statements below, with no operator action? Steam flow will increase and then (1) PK-464, STM HDR PRESS controller, will (2) (1) A. stabilize at 40% steam flow B. decrease to zero C. decrease to zero D. stabilize at 40% steam flow HLT34 RO NRC exam 5/24/2011 (2) remain in AUTO shift to MANUAL at 543° F remain in AUTO shift to MANUAL at 543° F Page 31 of 75

  • 32. Unit 1 is at 32% power with the foilowing.conditions:

At 10:00: Steam dumps are Tagged Out to prevent operation due to a maintenance test in progress. The control rods are in MANUAL. At 10:05: A malfunction of the DEH control system results in a Main Turbine trip. Which one of the following completes the statements below? SG water levels will (1) due to the Turbine trip. The OATC is required to (2) (1) (2) A. swell reduce Reactor power to < 8% B. swell trip the Reactor and enter EEP-O, Reactor Trip or Safety Injection C. shrink reduce Reactor power to <8% D. shrink trip the Reactor and enter EEP-O, Reactor Trip or Safety Injection HLT34 RO NRC exam 5/24/2011 Page 32 of 75

31 Umt 2 is ramping up with the following conidiitons: At 10:00: KKI, TURB COND VAC LO, comes into alarm. Condenser vacuum is degrading. AOP-8, Partial Loss of Condenser Vacuum, actions are in progress. AtlO:15: KK2, TURB COND VAC LO-LO, comes into alarm. Main Turbine load is 225 MWe. Condenser vacuum is 2.1 psia and stable. Which one of the following is/are the required action(s) per AOP-8.O? A. Trip the reactor and perform EEP-O, Reactor Trip or Safety Injection. B. Trip the Main Turbine and perform AOP-3.O, Turbine Trip Below P-9 Setpoint. C. Reduce load at the maximum controllable rate per AOP-1 7, Rapid Load Reduction. D. Stop the ramp in progress and stabilize the plant. HLT34 RO NRC exam 5/24/2011 Page 33 of 75

34 Unit I is shutdown. with the foLlowing conditions At 10:00: There is a complete loss of all AC power. A Safety Injection has occurred. ECP-O.O, Loss of All AC Power, is in progress. 1 B Diesel Generator (DG) is Tagged Out. 1-2A DG tripped on Low Lube Oil Pressure due to a clogged strainer. At 10:15: 1-2A DGs on service lube oil strainer has been swapped. 1-2A DG will be started locally in Mode 4 per SOP-38.1, Emergency Starting of a! Diesel Generator. Which one of the following completes the statements below? Prior to starting the 1-2A DG in Mode 4, the (1) must be depressed. To close the l-2A DG output breaker from the EPB, the 1-2A DG EPB Mode Selector Switch is required to be in the (2) position per SOP-38.O-1-2A, 1-2A Diesel Generator and Auxiliaries. A.

1) 1-2A DG ENGINE RESET pushbutton on the Local Control Panel
2) Mode 2 B.
1) 1-2A DG ENGINE RESET pushbutton on the Local Control Panel
2) Mode 3 C. 1) SIAS RESET pushbutton on the Bi F Sequencer
2) Mode 2 D. 1) SIAS RESET pushbutton on the B1F Sequencer
2) Mode 3 HLT34 RO NRC exam 5/24/20 1 1 Page 34 of 75
35. Uniti is at 70% power with thefaUowing cond[tins R-15A, SJAE EXH, is in alarm.

AOP-2.0, Steam Generator Tube Leakage, is in progress. The Turbine Building SO has placed the SJAE Filtration System in service. Which one of the following completes the statement below? After the SJAE Filtration system is placed in service, the reading on R-15A will (1) and the SJAE Filtration system will (2) (1) (2) A. decrease be aligned in a recirc alignment B. remain the same be aligned in a recirc alignment C. decrease discharge to the Turbine Bldg roof D. remain the same discharge to the Turbine Bldg roof HLT34 RO NRC exam 5/24/2011 Page 35 of 75

36. UfiLt I is at 100% power with the fUowin onon At 10:00:

1 B Condensate pump is in Standby and has a Caution tag stating that the pump has a degraded head condition. At 10:05: 1 C Condensate Pump trips. PR-4039, SGFP Suction Pressure recorder, indication drops to 274 psig for 20 seconds and then starts rising rapidly. KB4, SGFP SUCT PRESS LO, clears 25 seconds after the I B condensate pump starts. Which one of the following completes the statements below? The lB Condensate Pump started (1) The Control Room Crew is required to (2) per AOP-13, Condensate and Feedwater Malfunction. A.

1) immediately following the trip of the I C Condensate pump
2) trip the Reactor B.
1) immediately following the trip of the 1 C Condensate pump
2) stabilize Steam Generator levels C. 1) following a drop in SGFP suction pressure ONLY
2) trip the Reactor D. 1) following a drop in SGFP suction pressure ONLY
2) stabilize Steam Generator levels HLT34 RO NRC exam 5/24/201 1 Page 36 of 75
37. Unit 2 is in Mode 3 with the following conditions A Grid disturbance caused a dual unit LOSP.

The following 230KV High Voltage lines are out of service: Sinai Cemetery Bainbridge Webb

  1. 2 Auto Bank Transformer is out of service.

The Shift Manager has directed performance of STP-27.1, A.C. Source Verification, on Unit 2. Which one of the following completes the statements below? The Unit 2 Startup Transformers are powered from the (1) side of the High Voltage Switchyard. Per STP-27. 1, (2) available to supply power to the Unit 2 Startup Transformers. (1) (2) A. 230KV one off-site circuit is B. 500KV one off-site circuit is C. 230KV two off-site circuits are D. 500KV two off-site circuits are HLT34 RO NRC exam 5/24/2011 Page 37 of 75

38. The foLlowing conditions exist-on Unit 1:

At 10:00: Reactor power is 80% and stable. Rod control is in AUTO with Bank D rods at 184 steps. LT-1 15, VCT LEVEL, is failed LOW. N-43, POWER RANGE NUCLEAR INSTRUMENT, has failed HIGH. All actions of AOP-1 00, Instrument Malfunction, have been completed for N-43. At 10:15: Power is lost to the IC I 20V AC Vital Panel due to an Inverter malfunction. Which one of the following conditions will occur due to 1 C I 20V AC Vital Panel being de-energized? A. A reactor trip will occur. B. An Auto makeup will commence. C. Automatic rod withdrawal is blocked. D. LCV-115B and D, RWSTto CHG PUMP, will open. HLT34 RO NRC exam 5/24/2011 Page 38 of 75

39. The fol[ciwing conditions exist on Unit 2:

At 10:00: LBI8, 2B BATTERY SUPPLY BREAKER, is open and Tagged Out for Battery cell replacement. At 10:05: An LOSP occurs. Which one of the following completes the statement below? (1) Diesel Generator can be started used to supply power to the Unit 2 B Train 4160V ESF busses because it has a(n) (2) (1) (2) A. 2C power seeking ATS (Automatic Transfer Switch) B. 2C emergency Air Start Solenoid C. 2B power seeking ATS (Automatic Transfer Switch) D. 2B emergency Air Start Solenoid HLT34 RO NRC exam 5/24/20 1 1 Page 39 of 75

4O Uniti is at 13% powerwith the foUowg conditions: The Main Generator output breakers have been closed. JF1, IA SG LVL DEV, is in alarm. A Systems Operator in the Main Steam Valve Room reports that the air supply line to FCV-479, IA SG FW BYP FLOW, has blown off. Which one of the following completes the statements below? FCV-479 will fail (1) Per AOP-13.O, Condensate and Feedwater Malfunctions, the operator is required to trip the (2) if Steam Generator level can NOT be maintained. (I) (2) A. open Main Turbine B. open Reactor C. closed Reactor D. closed Main Turbine HLT34 RO NRC exam 5/24/2011 Page 40 of 75

(I) A. ALL AFW pumps B. ALL AFW pumps C. ONLY the TDAFW pump D. ONLY the TDAFW pump HLT34 RO NRC exam 5/24/2011 (2) water hammer or steam binding water hammer ONLY water hammer or steam binding water hammer ONLY

41. Which on of the following completes the £tatements e[ow?

I The purpose of TRSH-2293, AFW CHECK VALVE TEMPERATURE RECORDER, is to monitor the temperature on the discharge line of (1) Temperatures are monitored to determine if actions need to be taken to protect I against (2) Page 41 of 75

42. Unit 1 i&at 100% power with the following conditions:

At 10:00: Unit 1 trips due to a Loss of Site Power (LOSP). At 10:20: The IA Steam Generator narrow range water level is 25%. The lB and 1C Steam Generator narrow range water levels are 31%. The Rover reports that smoke is coming from the IA MDAFW pump. The UO takes the handswitch for the 1A MDAFW pump to stop. Which one of the following completes the statement below? When the IA MDAFW pump handswitch is taken to stop and released, the IA MDAFW pump will (1) because the (2) signal is present. (1) (2) A. stop and remain stopped SG LO-LO level B. stop and then restart SG LO-LO level C. stop and then restart LOSP D. stop and remain stopped LOSP HLT34 RO NRC exam 5/24/2011 Page 42 of 75

43.. Unit 1. is at 1 QO% power, with the folLowing conditions: A failure has occurred in the controller/positioner for HV-3235A, TDAFWP STM SUPP FROM I B SG, such that air is continuously supplied to HV-3235A. Which one of the following completes the statement below? The TDAFW pump will HLT34 RO NRC exam 5/24/20 1 1 A. B. C. D. NOT autostart under any condition. immediately start and operate at full design capacity. autostart when a signal occurs and operate at full design capacity. autostart when a signal occurs, but NOT operate at full design capacity. Page 43 of 75

44. Unit 1 has experienced a Reactor Trip and Safety Injection with the following alarms:

AF4, CTMT CLR SW FLOW HI-LO SETPOINT: Lo Flow Range (< 1980 gpm): Duff Flow HI: 300 +0, -75 gpm Hi Flow Range (> 1980 gpm): Diff Flow HI: 750 +0, -30 gpm AD4, SW PRESS ATRN LO SETPOINT: 60 +/- I psig Which one of the following would cause the conditions described above? A. The 1A Service Water Pump has degraded head. B. A piping failure has occurred upstream of the IA containment cooler. C. A piping failure has occurred downstream of the IC containment cooler. D. MOV-3024A, EMERG SW FROM IA CTMT CLR, has failed to open on the SI. HLT34 RO NRC exam 5/24/2011 Page 44 of 75

45. Unit 1 ha experienced a Reactor trip with the following conditions An LOSP has occurred.

A DG failure has occurred, and the A Train 4160V busses are de-energized. Which one of the following states the minimum time that the A Train Auxiliary Building 125V DC System Battery is designed to carry the required DC loads in this condition? A. 30 minutes B. 2 hours C. 8 hours D. 12 hours HLT34 RO NRC exam 5/24/2011 Page 45 of 75

46.. Unit I has experiencecla Reactoi trLia with the following conditions: A Loss of All AC has occurred. ECP-O.O, Loss of All AC Power, is in progress. Which one of the following completes the statements below? The I B Aux Building DC bus voltage will (1) DC loads are minimized in ECP-O.O to (2) A.

1) drop slowly at first; then later drop rapidly as the battery nears exhaustion
2) prolong battery life ONLY B.
1) drop slowly at first; then later drop rapidly as the battery nears exhaustion
2) prevent damage to the DC components AND prolong battery life C. I) drop at a constant, linear rate the entire time the battery discharges
2) prolong battery life ONLY D. I) drop at a constant, linear rate the entire time the battery discharges
2) prevent damage to the DC components AND prolong battery life HLT34 RO NRC exam 5/24/20 1 1 Page 46 of 75
47. Unit 1 is in Mode 3 with the foLLowing conditicins:

The I B MDAFW pump is operating to provide secondary inventory. The B Train Auxiliary Building 125V DC bus becomes de-energized. Which one of the following completes the statements below? The lB MDAFW pump Main Control Board switch indication will (1) The I B MDAFW pump will (2) (1) (2) A. NOT be LIT continue to run B. NOT be LIT trip C. be LIT continue to run D. be LIT trip HLT34 RO NRC exam 5/24/20 1 1 Page 47 of 75

4& Unit I is ir Mode 3 wfth the faI1ow conditions An LOSP has occurred on Unit I ONLY. The Diesel Building SO reports that crankcase pressure is out of spec on the 1 C DG. Which one of the following completes the statement below? The (1) CRANKCASE PRESSURE alarm comes in when 1C DG crankcase pressure reaches + 2 H 2 0 gauge and the IC DG will (2) (1) (2) A. HIGH TRIP B. LOW TRIP C. HIGH NOT trip D. LOW NOT trip HLT34 RO NRC exam 5/24/20 1 1 Page 48 of 75

4. Unit 1 tripped from IQO% power with the following conditions:

A steam line break occurred in Containment. In addition, a complete loss of all AFW occurred. FRP-H.1, Response To Loss Of Secondary Heat Sink, is in progress. Bleed and Feed criteria has been met. Containment pressure is 31 psig. Which one of the following completes the statements below? Bleed and Feed criteria was met as soon as two SG wide range levels were LESS THAN (1) Phase B isolation is reset in FRP-H.1 to (2) (1) (2) A. 12% restore CCW cooling to the RCPs B. 12% restore Instrument Air to Containment C. 31% restore CCW cooling to the RCPs D. 31% restore Instrument Air to Containment HLT34 RO NRC exam 5/24/2011 Page 49 of 75

50. Unit 1 ws operating with PT-474, 1A SQ PRESS, fai[ed LOW when the following occurred:

A fire onsite has required the Control Room to be evacuated. The crew has implemented AOP-28.2, Fire in the Control Room. Steam is coming from the MSVR roof. The crew has closed all MSIVs. The crew is evaluating PCV-3371A, IA SG ATMOSPHERIC RELIEF VLV, to determine if it is OPEN or leaking by. Which one of the following completes the statement below? The 1A SG Pressure indication (1) available for monitoring on the Hot Shutdown Panels. Low Steam Line Pressure SI signal (2) be blocked on the Hot Shutdown Panels. (1) (2) A. is NOT can NOT B. is NOT CAN C. IS can NOT D. IS CAN HLT34 RO NRC exam 5/24/20 1 1 Page 50 of 75

51. Unit I is at I OOk power with the fo11owing condiflcins:

Containment Mini-Purge is in service. R-24B, CTMT PURGE, has failed HIGH. Which one of the following completes the statements below? Mini-Purge dampers inside (1) will isolate. Mini-Purge supply and exhaust fans (2) (1) (2) A. Containment remain running B. Containment automatically stop C. the Piping Penetration room remain running D. the Piping Penetration room automatically stop HLT34 RO NRC exam 5/24/2011 Page 51 of 75

52. The foi[owing conditions exist on Unit 1:

The 1 B MDAFW pump has been started from the MCB and is running for STP-22.2, I B MDAFW Pump Quarterly Inservice Test. R-19, SGBD SAMPLE, radiation monitor is in alarm and indication is stable above the alarm setpoint. The Shift Radio Chemist requests to sample the Steam Generators. Which one of the following describes the actions that will allow the Shift Radio Chemist to obtain a sample of the Steam Generators per SOP-45.O, Radiation Monitoring System? A. Pull the INSTRUMENT power fuses for R-19, then open the sample valves. B. Pull the DC power fuses to each sample valve solenoid to fail the valve open. C. Place 1 B MDAFW pump handswitch to the STOP position, then open the sample valves. D. Place R-19 Operation Selector Switch to the RESET position, then open the sample, valves. HLT34 RO NRC exam 5/24/2011 Page 52 of 75

53. Unit 2 is at 31% power with the following conditions A lightning strike causes the 2A AND 2B Circulating Water pumps to trip.

Main Condenser pressure is 6.0 psia and degrading rapidly. All Steam Generator narrow range levels are 50% and slowly falling. Which one of the following completes the statement below? An automatic Reactor trip (1)

occurred, (2)

(1) (2) A. HAS Steam Dumps have opened B. HAS MDAFW pumps have started C. has NOT Steam Dumps have opened D. has NOT MDAFW pumps have started HLT34 RO NRC exam 5/24/2011 Page 53 of 75

5& Unit 1 isat 25% power with the owhigcond[tions At 10:00: The 1A S/U transformer is do-energized. The 1-2A DG restores power to the Unit I ESF busses. AtlO:15: A Safety Injection occurs. Which one of the following describes the position of SW TO TURB BLDG ISO MOVs, 514, 515, 516, 517, following the Safety Injection? A. MOVs powered from A Train are throttled, MOVs powered from B Train are closed. B. MOVs powered from A Train are closed, MOVs powered from B Train are throttled. C. All MOVs are throttled. D. All MOVs are closed. HLT34 RO NRC exam 5/24/2011 Page 54 of 75

55. Unit 1 has high reactor coolant activity due to failed fuel. as indicated by an iipscale reading on the Gross Failed Fuel Detector (GFFD).

Which one of the following completes the statements below? The GFFD provides indication of failed fuel by detection of (1) The GFFD (2) on a high radiation signal. (1) A. N-16 gamma radiation B. N-16 gamma radiation C. delayed neutrons D. delayed neutrons HLT34 RO NRC exam 5/24/20 1 1 (2) automatically isolates the RCS sample system provides NO automatic isolation automatically isolates the RCS sample system provides NO automatic isolation Page 55 of 75

56. Which one of the following ompIetes th& statement bekw?

MOV-515, SW TO TURB BLDG ISO, on Unit I is powered from 600V (1) ,which is supplied from a(n) (2) Diesel Generator during an LOSP. (I) (2) A. MCCIN ATrain B. MCCIT ATrain C. MCC 1 N B Train D. MCC IT B Train HLT34 RO NRC exam 5/24/2011 Page 56 of 75

57. The folLowing conditions exist on Unit 2:

At 10:00: Reactor power is 25% and stable. PCC (Power Control Center) has notified the Control Room that the offsite grid has become degraded. At 10:05: Multiple alarms occur in the Unit 2 Control Room. Which one of the following alarms that are LL! will be addressed and actions performed FIRST? A. EF1, 2A RCS LOOP FLOW LO OR 2A RCP BKR OPEN (Red Window) B. YE2, 2G 4KV BUS OV-OR-UV OR LOSS OF DC (White Window) C. KG2, EH FLUID LEVEL LO-LO (Red Window) D. MB1, 2B S/U XFMR UV (White Window) HLT34 RO NRC exam 5/24/2011 Page 57 of 75

58. Unit I Air Compressor& are aligned En the following configuration:

The 1A air compressor panel key switch is in the MCB position and the AUTOMATIC OPERATION LED (green light) is LIT. The I B and IC air compressors are aligned to the sequencer panel. Which one of the following describes the reason for this alignment? A. To prevent a complete loss of Instrument Air pressure due to a failure of the sequencer panel pressure transducer. B. To prevent a complete loss of Instrument Air pressure due to a loss of power to the sequencer panel. C. To ensure that the IA air compressor is available to be started from the ESS or LOSP Sequencer. D. To ensure that all three air compressors do not run at the same time and possibly overheat due to insufficent Service Water flow. HLT34 RO NRC exam 5/24/2011 Page 58 of 75

59. Which one of the following describes th correc,t configuration for the Containment Main Personnel Access Hatch doors and equaNzing valves while the airlock is in use for entering/exiting Containment?

A. Outer door OPEN Outer door equalizing valve OPEN Inner door CLOSED Inner door equalizing valve CLOSED B. Outer door OPEN Outer door equalizing valve OPEN Inner door CLOSED Inner door equalizing valve OPEN C. Outer door CLOSED Outer door equalizing valve OPEN Inner door OPEN Inner door equalizing valve CLOSED D. Outer door CLOSED Outer door equalizing valve CLOSED Inner door OPEN Inner door equalizing valve CLOSED HLT34 RO NRC exam 5/24/20 1 1 Page 59 of 75

60. Unit I hs exprenGed a Reactor Trip and Safety Injection due to a LOCA, with the following conditions:

EEP-0, Reactor Trip or Safety Injection, has been completed and EEP-1, Loss of Reactor or Secondary Coolant, has been entered. AOP-34.0, Malfunction of RCS Wide Range Pressure Indication, has been implemented to determine actual RCS pressure. PT-455, 456, 457, PRZR PRESS, all indicate 1700 psig. PT-402, RCS WR PRESS, indicates 1600 psig. PT-403, RCS WR PRESS, indicates 750 psig. FI-943, A TRN HHSI FLOW, indicates 550 gpm. Which one of the following completes the statements below? AOP-34.0 will require Charging Pump Miniflow valves to be (I) prior to RCS pressure determination. Actual RCS pressure is (2) References Provided (1) (2) A. open 750 psig B. open 1600 psig C. closed 750 psig D. closed 1600 psig HLT34 RO NRC exam 5/24/20 1 1 Page 60 of 75

61. Unit t is in Mode-I at 100% power with the foowwig nditions.

Chemistry reports that RCS Dissolved Oxygen is 50 ppm. Which one of the following completes the statements below? PerTRM 13.4.1, RCS Chemistry, the RCS Dissolved Oxygen limit (1) been exceeded. (2) is used to control RCS Dissolved Oxygen in Mode 1. (1) (2) A. has NOT Hydrazine B. HAS Hydrazine C. has NOT Hydrogen D. HAS Hydrogen HLT34 RO NRC exam 5/24/2011 Page 61 of 75

62. A one step Tagout has heer issued to place a Danger Tag on an MOV handwheel.

The following condition exists: A Caution Tag is on the handwheel of the MOV. Which one of the following completes the statement below? Per NMP-AD-003-OO1, Tag Standards, the operator is required to A. return the Tagout to the Tagging Official because two tags cannot exist on the same component. B. place the Danger tag on the MOV handwheel, remove the Caution Tag, and return it to the Tagging Official. C. place the Danger tag on the MOV handwheel and ensure the Danger Tag is visible on top of the Caution Tag. D. place the Danger tag on the MOV handwheel and move the Caution Tag to another visible location on the MOV. HLT34 RO NRC exam 5/24/2011 Page 62 of 75

63. Unit 2 is shutdown with the following conditk>ns:

All Reactor Trip breakers are open. RCS pressure is 2200 psig. RCS temperature is 540° F and slowly decreasing. N-31, Source Range NI, is out of service for repairs. N-32, Source Range NI, has just failed LOW. A channel check on Gamma Metrics Source Range instrumentation has been performed. Which ONE of the following describes Tech Spec 3.3.1, Reactor Trip System (RTS) Instrumentation, REQUIRED ACTION due within one hour for these conditions? A. Verify shutdown margin. B. Verify interlock is in required state. C. Commence an RCS heatup to 547° F. D. Place channel N-32 in the tripped condition. HLT34 RO NRC exam 5/24/20 1 1 Page 63 of 75

64 Unit I is 4n Mode 5 for a refueng outage. A sma accessible area in containment has general area dose rate of 1150 mrem/hr. The top of this area cannot be enclosed for the purpose of locking the area. Which one of the following completes the statement below? Per Tech Spec 5.7.3, in addition to the area being barricaded off, the minimum control(s) required for this area is/are to A. be conspicuously posted ONLY B. be conspicuously posted AND have a flashing light C. have continuous surveillance by closed circuit TV ONLY D. have continuous surveillance by closed circuit TV AND have a flashing light HLT34 RO NRC exam 5/24/2011 Page 64 of 75

65. You have been given a task to Rerforn an inspection of the Containment Equipmen Sump. PO17A & B, CTMT SUMP PUMP handswitches are in the Pull-to-Lock position on the BOP.

Which one of the following is a condition that would result in excessive radiation exposure rates in the Containment Equipment Sump Area? A. Draining the RCS to mid-loop prior to core off load. B. Withdrawal of the Incore Detectors from the core. C. Movement of irradiated fuel in the reactor vessel. D. A leak in the Auxiliary Building results in lowering Reactor Cavity level. HLT34 RO NRC exam 5/24/2011 Page 65 of 75

&& Which Qneof the foIIow completes the statement below? The maximum aNowable exposure that may be required when performing emergency on-site actions to protect valuable property is per EIP-14.0, Personnel Movement, Relocation, Re-entry and Site Evacuation. A. 5Rem B. 10 Rem C. 25 Rem D. 100 Rem HLT34 RO NRC exam 5/24/2011 Page 66 of 75

67. Unit I has entere1 ESP-I 3 Transfer To Cold Leg Recirculation.

Which one of the following states the action required for implementing the Functional Restoration Procedures (FRPs) while in ESP-1.3, and the basis for the action? A. FRPs should not be implemented until RHR and Charging pumps are aligned for recirculation and flow is stable. This is because of the limited amount of water in the RWST available for maintaining suction to ECCS pumps. B. FRPs should not be implemented while in ESP-I.3 until RWST level is <4.5 feet. This is because insufficient water may be present in the Containment Sump to prevent cavitation while on recirculation. C. FRPs should be implemented immediately at any time while in ESP-1.3. This is because of the limited amount of water in the RWST available for maintaining suction to ECCS pumps. D. FRPs should be implemented immediately at any time while in ESP-l.3. This is because they are always the highest priority while in the Emergency Procedures. HLT34 RO NRC exam 5/24/2011 Page 67 of 75

68. The following conditionsxist.on UNIT t MH1, FIRE, annunciator on the Unit 1 Main Control Board is in alarm and is LIT solid (NOT flashing).

The Control Room Fire Alarm Panel has a single window in alarm, which contains the following information: Aux Bldg El 139 W Side Det IA-39, 43, 46, 53 IA-55, 59, 106 At the PYR-A-LARM Panel, the window for IA-59 panel is lit. Which one of the following describes the MINIMUM actions required to enable MHI, FIRE, to reflash fora fire detection system actuation in zone IA-106 per SOP-O.4, Fire Protection Administration Procedure? A. The Control Room Fire Alarm Panel must be acknowledged AND Zone IA-59 placed in OVERRIDE at the PYR-A-LARM Panel. B. The Control Room Fire Alarm Panel must be acknowledged AND the Local Reflash Panel alarm for detection system IA-59 must be acknowledged. C. ONLY the Control Room Fire Alarm Panel must be acknowledged. D. ONLY the Local Reflash Panel alarm for detection system IA-59 must be acknowledged. HLT34 RO NRC exam 5/24/201 1 Page 68 of 75

69 Unit I has had a Reactor trip arid Safety [njection ac,tuation with the following conditions: A LOCA has occurred in containment. EEP-0, Reactor Trip or Safety Injection, is in progress. RCS pressure is 1100 psig and stable. Containment pressure is 12 psig and slowly rising. Which one of the following is an annunciator that will be in alarm at this time? A. MOB alarm JHI, IA SG MSIV CLOSED B. MCBalarm CDI, IAAOOUM PRESS HI-LO

0. MOB alarm HD2, PRZR PRESS SI PORV BLOCK P-I I D. BOP alarm LB3, RCP THRM BARR ISO HV-3184 AIR PRESS LO HLT34 RO NRC exam 5/24/2011 Page 69 of 75
70. The foiIowin conditions exist on Unit 1:

A Small Break LOCA has occurred. Natural circulation has been established. The crew is performing ESP-1.2, Post LOCA Cooldown and Depressurization. Which one of the following completes the statements below per ESP-1.2? Opening (1) may cause voiding to occur. Voiding is detected by (2) A.

1) the steam dumps to establish a cooldown rate of 85°F/hr
2) LI-460, PRZR LVL, rapidly increasing B.
1) one PORV to reduce RCS pressure to refill the pressurizer
2) Ll-460, PRZR LVL, rapidly increasing C.
1) the steam dumps to establish a cooldown rate of 85°F/hr
2) Tl-2301, CORE EXIT THERMOCOUPLE MONITOR, rapidly increasing D. 1) one PORV to reduce RCS pressure to refill the pressurizer
2) Tl-2301, CORE EXIT THERMOCOUPLE MONITOR, rapidly increasing HLT34 RO NRC exam 5/24/2011 Page 70 of 75
71. The crew h transitined to CP..1 2, LOCA Outside Containment.

Which one of the following completes the statements below per ECP-1.2? (1) piping will be isolated. The instrumentation used to determine when the intersystem LOCA has been isolated is (2) A.

1) Low Head Safety Injection
2) Auxiliary Building radiation monitors decreasing B.
1) High Head Safety Injection
2) Auxiliary Building radiation monitors decreasing C. 1) Low Head Safety Injection
2) RCS LOOP Wide Range pressure indicators increasing D. 1) High Head Safety Injection
2) RCS LOOP Wide Range pressure indicators increasing HLT34 RO NRC exam 5/2412011 Page 71 of 75

72 A loss of ALL feedwater has occurred on Unit 1. The team is implementing FRP4-{.1, Response to Loss of Secondary Heat Sink, and the following conditions exist: SI has NOT actuated. RCS temp is 547°F. IA SGFP has just been started and has been aligned to feed all SGs. Attachment I, MAIN FEEDWATER BYPASS VALVES AUTOMATIC CLOSURE DEFEAT, has been completed. The red light is LIT on the following handswitches: MOV-3232A, MAIN FW TO 1A SG STOP VLV MOV-3232B, MAIN FW TO lB SG STOP VLV MOV-3232C, MAIN FW TO IC SG STOP VLV Immediately upon feeding the SGs, GB5, STM LINE LO PRESS RX TRIP SI, annunciator comes into alarm. Which one of the following completes the statement below? The 1ASGFP (1) trip. MOV-3232A, B, C (2) automatically close. (1) A. will NOT (2) will NOT HLT34 RO NRC exam 5/24/2011 B. will NOT C. WILL D. WILL WILL will NOT WILL Page 72 of 75

73. FRP-P.l, Response to 1mrniint Pressurized Therma Shock Conditions, has been entered on Unit 1.

A one hour soak is required. Which one of the following completes the statements below per FRP-P.1? The soak allows thermal gradients on the (1) to be reduced, thus reducing corresponding stresses. If a cooldown is required AFTER the soak, the maximum cooldown rate is (2) in any 60 minute period. A.

1) Steam Generator shell wall
2) < 50°F B.
1) Steam Generator shell wall 2)<100°F C. 1) Reactor Vessel wall 2)<50°F D. 1) Reactor Vessel wall
2) < 100°F HLT34 RO NRC exam 5/24/20 1 1 Page 73 of 75
74. Unit I has experienced aReactor trip and Safety Injection with the following conditioni1 At 10:00:

EEP-1.0, Loss of Reactor or Secondary Coolant, is entered due to a LOCA. The following equipment problems have occurred: IA RHR pump is tripped. MOV-3185A, COW TO 1A RHR HX, will not open. 1 C Charging Pump is tripped (1 B Charging Pump is on A Train). MOV-8827B, CTMT SUMP TO I B CS PUMP, breaker is tripped. MOV-8706B, 1 B RHR HX TO CHG PUMP SUCT, breaker is tripped. At 10:10: ECP-1.1, Loss of Emergency Coolant Recirculation, is entered. Which one of the following equipment failures, if corrected, will restore Emergency Coolant Recirculation and allow exit of ECP-1.1? A. Power restored to MOV-8827B. B. 1A RHR pump returned to service.

0. Power restored to MOV-8706B.

D. 1C Charging pump returned to service. HLT34 RO NRC exam 5/24/2011 Page 74 of 75

75 Unit I has experienced a Large Break LOCA with the following conditions: Containment pressure is 32 psig. Containment sump level is 7.2 feet. ONLY lB Containment Spray pump is running. Containment Spray flow is 1600 gpm. Which one of the following completes the statement below? A Containment CSF Status Tree ORANGE path A. exists for BOTH FRP-Z.l, Response To High Containment Pressure AND FRP-Z.2, Response To Containment Flooding B. does NOT exist for EITHER FRP-Z.1, Response To High Containment Pressure OR FRP-Z.2, Response To Containment Flooding C. exists for ONLY FRP-Z.2, Response To Containment Flooding D. exists for ONLY FRP-Z.1, Response To High Containment Pressure HLT34 RO NRC exam 5/24/2011 Page 75 of 75

1bkTfA1+/-tD j I I I c3DcDciDc Dc I) TD cr w; cccc S C A \\ T R Q \\ EM-F18278-2:6543 EDO5 Ro © SCANTRON CORPORATION 2008 ALL RIGHTS RESERVED.

Ro T3T FOUvi U GD GD GD GD r L) EAST NM[- FfRST-NAME-- 1M IIklIIlI illIlil c c c

c. c @

CD c c GDGDCGDGD GDGDGD TGDcDQDDDTGDcDcDDDDLODTaDT 1GDfl DLc ccc GDGDGDGDGDGDGDGDGDGDGDGDGDGDGDIGD GDGDGDGDGDGDGDIGDGDGDGDGDflL GDGDGDGD GDGDGDGD GDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGD GDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGDGD GD GD GD GD GD GD GD GD GD GD GD GD GD GD GD GD GD GD GD GD GD SOUTHERNt COMPANY EXAMPLE: GD* ERASE COMPLETELY TO CHANGE (T) (F) (T) (F) (T) (F) (T) (F> ) 5t () 7SGDGD GD GD Cc: 27 52 77 GD GD GD 3GDGD GD 28 Ca) ( GD 53GD GD ) Q) 29 GD GD 54CA GD GD 79GD GD GD GD GD GD GD 55GD GD GD G) GD GD GD GD GD JtGD GD GD CL GD GD 2 GD (2) GD (2) 7GD GD GD 32GD 2) 12) 57 (2) 2) (2) 2AD GD GD (2) GD (2) 33GD GD GD 58 (2) (2) (2) 83.iD (2) GD (2) 9% GD GD 34$ (2) GDCL 59$ GD CL (2) S4GDGDGD 1OGD GDG) 35.GD GD GD SOJA. )2) 85JA GD GD (2) 11 GD GDGD (2) 61.GD GD 8S. GDCL GD 12GZ GD GD 62 GD (2 87.GD GD GD CL 13(2D GD (2) 38GD (2) CL GD CL (2) 8B CLGDGD 14G C2D* (2) 39$ (2) (2) (2) Cc. (2) 89GD GD GD (2) 15 GD GD CL 40,GD (2) GD 6&GD GD (2) 92)GD GD 2) (2) (2) CL (2) GD GD 66GD GD (2 9tGD CL GD (2) 1(2D GD GD 2GD CL (2 (2) GD GD 92J GD GD GD 1&CDGD GD 43GD GD (2) 68.

GD GD 93GD GD GD CL 19.(2) GD GD 44.(2) (2) CL 69.GD GD CL 94GD GDGDGD 2O(2) CL CL 45GD GD (2) 7(L(2D

  1. GD GD 95GD GDGD CL 2tGD (2)

(2) 4$ (2) (2) (2) 7tG) CL$ CL 96.(2DCLGDGD 22GD ø GDGD 41$ GD GD CL 72GD CL CL 97.CAD CL CL (2) 23GD CL GD 48.GD (2)0 CL 73GD C2D (2) 98D GD (2) (2) (2) GD (2) 49GD (2) GD 74(2) (2) (2) 99GD CL GD (2) 22)GD CL (2) CL 0 CL 75GD 0 CL (2) iOu,C2) (2) 12) (2)

£17113/la 8L18:46

FNP-1-AOP-34.0 MALFUNCTION OF RCS WIDE RANGE PRESSURE Version 8.0 INDICATON 2500 2000 1500 RCS Pressure P$1G) .t000 500 FIGURE 1 ONE CHARGING PUMP RUMTING IN SI MODE I CHG. Puma in SI Mode CS Pressure vs. Si Injection 1owrate Injection Flowrate (GPM) Page 1 of I

07/la/b 8:08:46 FNP-l-AOP-340 MALFUNCTION OF RCS WIDE RANGE PRESSURE Version 8.0 INDICATON Page Completed FIGURE 2 TWO CHARGING PUMPS RUNNING IN SI MODE 2 CHG. Pump in SI Mode CS Pressure vs. S fnjection Plowrate Injection Fowrata (GPM) 2500 2000 1500 RCS (PSIG) 1000 500 0 r T

N\\ 100 200 300 400 500 800 700 800 900 Page 1 of 1

07/13/10 80&46 FNP-1 -AOP-34.0 MALFUNCTION OF RCS WIDE RANGE PRESSURE INDICATON FIGURE 3 Version 8.0 THREE CHARGING PUMPS RU1NTNG IN SI MODE 3 CHG. Pump in SI Mode RCS Pressure vs. Si Injection Flowrats 2500 2000 1500 RCS Pressure (PSJG) 1000 500 NN N 200 300 400 500 600 Iniection Flowrate (GPM) o 700 800 900 Page 1 of 1}}