2 Table of Contents Executive Summary.................................................................................................................................. 3 Introduction............................................................................................................................................... 5 Emergency Diesel Generators: Decades of Reliability and Maintenance Problems................................. 9 Spent Nuclear Fuel: Regulatory Loopholes............................................................................................ 10
Background:
........................................................................................................................................ 10 Earthquakes and Spent Fuel Pool Integrity......................................................................................... 11 Spent Nuclear Fuel Pools Contain No Protections from Hydrogen Explosions................................. 12 There is No Regulatory Requirement for Some Spent Nuclear Fuel Pools to Have Emergency Power Capability............................................................................................................................................ 13 Hydrogen Explosions: NRC Regulations Are Lacking, and NRC Officials Have Made Misleading Statements Related to their Use.............................................................................................................. 14 Seismic Safety: NRC Has Not Factored Modern Geologic Information Into Reactor Safety................ 16
Background:
........................................................................................................................................ 16 Case Study: Diablo Canyon................................................................................................................ 17 Seismic Concerns: Not just at West Coast reactor sites...................................................................... 19 NRCs Post-Fukushima Efforts: Scope Limitations and Secrecy Concerns........................................... 22 Table 1. National responses to Japanese nuclear disaster....................................................................... 24 Table 2 - Summary of Emergency Diesel Generator (EDG) Inoperability 2002-2010.......................... 25
3 Executive Summary In the wake of the Fukushima Daiichi meltdown in Japan, the Nuclear Regulatory Commission (NRC) established1 an agency task force to conduct a review of the lessons that can be learned from the Tohoku earthquake and the tragic, ongoing events at the Fukushima nuclear power plant that have followed. The task forces stated goal is to Evaluate currently available technical and operational information from the events that have occurred at the Fukushima Daiichi nuclear complex in Japan to identify potential or preliminary near term/immediate operational or regulatory issues affecting domestic operating reactors of all designs, including their spent fuel pools, in areas such as protection against earthquake, tsunami, flooding, hurricanes; station blackout and a degraded ability to restore power; severe accident mitigation; emergency preparedness; and combustible gas control.
However, an examination of NRC regulations demonstrates that flawed assumptions and under-estimation of safety risks are currently an inherent part of the NRC regulatory program, due to a long history of decisions made by prior Commissions or by the NRC staff that have all too often acquiesced to industry requests for a weakening of safety standards. Coupled with reports that the near-term inspections being conducted at United States nuclear power plants may be limited in scope2 and subject to restrictions on public disclosure, it would be unwise to move forward with any pending licensing actions before the NRC fully completes its review and upgrades of its safety requirements.
The NRCs stated commitment to learn from the recent Japanese disaster is undermined both by its post-Fukushima approvals of license extension applications for Vermont Yankee Nuclear Power Plant in Vermont and Palo Verde Nuclear Generating Station Units 1, 2, and 33 in Arizona and by its apparent failure to fully explore all the vulnerabilities the Fukushima meltdown has revealed.
This report represents a partial summary of regulatory inadequacies, practices and decisions that impair effective nuclear safety oversight, some of which have occurred in the wake of the Japanese meltdown. Key findings include:
- The failure of the emergency diesel generators following the loss of off-site electricity led to the meltdowns at the Fukushima reactors. Despite decades of reported problems and NRC warnings, a review of NRC documents conducted by the staff of Congressman Edward J.
Markey indicates that there have been recurrent and prolonged malfunctions of emergency diesel generators at nuclear power plants in the U.S. In the past eight years there have been at least 69 reports of emergency diesel generator inoperability at 33 nuclear power plants. A total of 48 reactors were affected including 19 failures lasting over two weeks and 6 that lasted longer than a month.
1 http://www.nrc.gov/reading-rm/doc-collections/news/2011/11-055.pdf 2 http://markey.house.gov/docs/4.15.11.nrc.pdf 3 http://www.nrc.gov/reactors/operating/licensing/renewal/applications/palo-verde.html
4
- There never have been any requirements in the U.S. for spent fuel pools to include technologies to prevent the same kind of hydrogen explosions that reportedly occurred at spent nuclear fuel pools in Fukushima. Alarmingly, NRCs regulations do not require emergency diesel generators to be operational at times when there is no fuel in the reactor core, even though this could leave spent nuclear fuel pools without any backup cooling systems in the event of a loss of external electricity to the power plant. Finally, NRC has not required its licensees to reduce the amount of nuclear fuel stored in its spent nuclear fuel pools by moving it to dry cask storage, a safer means of storage that would reduce the risk of fire and radiation release in the event of an accident.
- NRC has removed its regulatory requirements for reactor containments to include technologies to prevent hydrogen explosions, even as NRC officials repeatedly and inaccurately asserted that such technologies were absent in Japan but are required in the U.S.
- The NRC has not factored modern geologic information into seismic safety requirements for nuclear power plants, and has not incorporated its technical staffs recommendation to do so even though the new information indicates a much higher probability of core damage caused by an earthquake than previously believed. In fact, the NRC has continued to process applications for license extensions for many nuclear reactors, including Pilgrim (which is approximately 38 miles from Boston) and Indian Point (which is approximately 25 miles from New York City), even in the absence of upgraded seismic safety requirements.
- NRCs post-Fukushima inspections in the U.S. appear to be limited in scope, and its U.S.
nuclear reactor inspection reports will likely exclude vulnerabilities from both the NRC and the public due to limitations imposed by the NRC.
5 Introduction Four days before the Tohoku earthquake Rep. Markey wrote to the Nuclear Regulatory Commission (NRC) to urge it to postpone action on the pending NRC approval of the AP 1000, a new nuclear power plant design4. One of the NRCs most senior scientists had warned that the containment structure for this reactor design would not be able to withstand a strong earthquake, because 60% of it is made of a material that is so brittle it could shatter like a glass cup under sufficient stress.5 As the non-concurring scientist noted, Brookhaven National Lab scientists found that Westinghouse appeared to have used an inappropriate pushover earthquake model that may have ignored the actual back-and-forth forces that occur in an actual earthquake, and instead assumed that such forces would only be imposed in a single direction.6 It is not just the designs for new nuclear power plants that raise serious concerns regarding the ability of domestic nuclear power plants to maintain safe operations and safe shut-down even in the face of a beyond design-basis event or near-concurrent series of events. The Fukushima Daiichi meltdown was initiated by the combination of an earthquake and tsunami, but it was the prolonged loss of external electricity coupled with the failure of the emergency backup diesel generators that ultimately prevented the safe shut-down of these nuclear reactors and led to the subsequent core meltdowns, spent fuel pool damage and radiation release.
Like all nuclear reactors, including those in the United States, the Fukushima Daiichi nuclear power plant needed electricity to run the plants cooling systems, which prevent the reactors from melting down. The cooling systems also keep the spent nuclear fuel from overheating or releasing radiation. To deal with potential loss of electrical power to the plant, Fukushima Daiichi, like American nuclear power plants, had diesel-powered backup generators.
But the water from the tsunami went right past the sea walls at Fukushima, swamping the generators. The water also flooded the electrical control rooms at the plant, preventing backup generators from being hooked up.
Without electricity to pump in fresh coolant to the reactor cores and their spent fuel pools, they overheated, resulting in hydrogen explosions (including suspected hydrogen explosions at spent nuclear fuel pools which have not previously been experienced or contemplated), partial core meltdowns, and continuing radiation release. Spent nuclear fuel rods are also leaking radiation into the water that is being used to cool them, which itself is leaking into other areas of the power plants and into the surrounding area. With no way to circulate water through the reactors or their spent fuel pools mechanically, the Japanese were forced to take the extraordinary step of attempting to flood them with seawater using helicopters and water 4 http://markey.house.gov/docs/3-7-11.ejmtonrc.pdf 5 The dissenting Non-Concurrence is available under Accession Number ML103370648 within the NRC Agencywide Documents Access and Management System (http://www.nrc.gov/reading-rm/adams/web-based.html).
6 R. Morante, M. Miranda, J. Nie. Technical Evaluation: AP1000 Shield Building Design Report, Revision 2. Dated 5/30/2010. Submitted as part of Dr. Mas rebuttal to the staff response to the Non-Concurrence statement.
Accession Number ML103370648 within the Agencywide Documents Access and Management System (http://www.nrc.gov/reading-rm/adams/web-based.html).
6 cannons, placing emergency responders in harms way as they were undoubtedly exposed to dangerous radiation levels.
Once emergency responders began to utilize ocean water to flood the reactor vessels and spent fuel pools, the heat from the nuclear fuel rods caused the water to boil off, leaving a crust of salt that filled the reactor vessels and coated the fuel, making efficient cooling all but impossible. While the Japanese have since procured sufficient stores of fresh water in an attempt to mitigate the salt build-up, these and other efforts to cool the reactors have been delayed by the discovery of high levels of radioactive water that are reported to contain short-lived fission byproducts in the basements of Units 1-3, which caused two workers to receive serious radiation burns to their legs and again raised concerns that the reactor vessels may be more severely damaged than they were previously believed to be. 7 On April 4, the Tokyo Electric Power Company began dumping more than 11,000 tons of radioactive water, about 100 times more radioactive than Japans legal limit, from the Fukushima Daiichi nuclear plant into the Pacific Ocean8. Workers also resorted to using shredded newspaper, sawdust, and a material used in diapers9, in attempts to stop a leak of seven tons an hour of even more highly radioactive water escaping from a pit near the reactor into the ocean10.
The radiation released from the Daiichi reactors has already caused considerable damage. The Department of Energy has projected what the dose could be to people living around the plant up to about 50 miles away over the first year of the nuclear disaster based on aerial radiation survey data11. People are expected to be exposed to about 2,000 millirems in the first year in a swath of land extending about 30 miles to the northwest of Fukushima Daiichi. The exposure estimate assumes that people did not evacuate and do not heed advice to shelter indoors throughout the year. The Japanese government has evacuated people out to 19 miles, and advised evacuation in selected places beyond that distance because of high localized fallout. Thousands of farmers have had to dump tons of produce and millions of gallons of dairy across a swath of north-central Japan where the government has determined radiation makes the food unsafe.12 Residents in Tokyo, about 150 miles from the Fukushima reactors, were warned temporarily not to allow infants to drink tap water because it contained unsafe levels of radioactive iodine. On April 2, seawater leaking from a crack near unit 213 had levels of radioactive iodine-131 that were 7.5 million times Japans legal limit, and radioactive cesium-134 at a concentration 2 million times that was allowed14. As seawater used to cool the reactor was released back to the ocean, radioactive iodine in the ocean 30 miles from Fukushima Daiichi spiked to 2800 times the legal limit on April 7th, while radioactive cesium-134 levels were at 1100 times the legal limit, and cesium-137 at 760 times the limit15. Radioactive cesium-134 remained at twice the legal limit at the same sampling location on May 6, 201116. Thousands of miles away, radioactive 7 http://www.nytimes.com/2011/03/30/world/asia/30japan.html 8 http://www.nytimes.com/2011/04/05/world/asia/05japan.html 9 http://english.kyodonews.jp/news/2011/04/82882.html 10 http://www.nytimes.com/2011/04/05/world/asia/05japan.html 11 http://news.sciencemag.org/scienceinsider/2011/04/a-map-of-fukushimas-radiation.html 12 http://www.nytimes.com/2011/03/30/world/asia/30farmers.html?pagewanted=1 13 http://www.tepco.co.jp/en/press/corp-com/release/betu11_e/images/110405e31.pdf 14 http://www.tepco.co.jp/en/press/corp-com/release/11040506-e.html 15 http://www.tepco.co.jp/en/press/corp-com/release/11040815-e.html 16 http://www.tepco.co.jp/en/press/corp-com/release/11050707-e.html
7 iodine from Japan has been found in Boston rainwater, although at levels far lower than those that would pose a threat to human health.17 While radioactive iodine rapidly decays, with a half life of 8 days, other radioactive elements being released are longer-lasting. The three plutonium isotopes found in Japanese soil samples have environmental half-lives of 87 - 24,000 years. Cesium-134 has a half-life of 2 years, and cesium-137 a half-life of 30 years. Cesium is also absorbed by marine organisms. As of April 28, radioactive cesium has been detected in 41 species off the coast of Japan18. In the Pacific sandlance, radioactive cesium has been found at levels as high as 14,400 Bequerels per kilogram, about 29 times the legal limit. The Pacific sandlance is eaten by many in Japan, and additionally serves as food for other fish, and cesium tends to bio-magnify, becoming increasingly concentrated as it moves up the food chain19. The Pacific sandlance is eaten by many migratory species, including other fish (salmon, bluefin tuna, skates, cod), seabirds (murres, auklets), and marine mammals (minke whales, seals). When present in a person or other animals, plutonium and cesium continue, for years or even decades, to expose surrounding tissue to radiation that can lead to cancer.
In recognition of the high levels of radiation emitted, on April 12, Japanese authorities raised their assessment of the Fukushima Daiichi nuclear meltdown to a Level 7 Major Accident 20. According to the International Nuclear and Radiological Event Scale of the International Atomic Energy Agency, level 7 means A major release of radioactive material with widespread health and environmental effects requiring implementation of planned and extended countermeasures". Only once before, during the Chernobyl meltdown of 1986, has there been such a severe nuclear disaster21 that rated this highest possible classification.
It is clear that the environmental consequences of Fukushima will be broad, severe, long-lasting, not previously contemplated by nuclear regulators in any country, and significant. Yet these consequences were not even fully understood, let alone factored into any of the Commissions post-Fukushima decisions to grant license extensions for four nuclear reactors by way of a revised or supplemental Environmental Impact Statement or by way of new safety requirements22.
In stark contrast to steps taken by other countries to cancel, postpone or otherwise re-assess nuclear reactor safety in the wake of the events in Japan (see Table 1 for a summary of other countries announcements), the NRC has continued to process applications for new licenses and licenses extensions even before it has completed its reviews of U.S. nuclear safety.
As Martin J. Virgilio, NRCs Deputy Executive Director for Reactor and Preparedness Program, stated on April 6 before the House Energy & Commerce Committee We have been closely monitoring the activities in Japan and reviewing all currently available information. Review of this information combined with our ongoing inspection, licensing and oversight allows us to say 17 http://www.wbur.org/2011/03/28/japan-radiation 18 http://www.jfa.maff.go.jp/e/q_a/
19 http://www.ncbi.nlm.nih.gov/pubmed/12527234 20 http://www.iaea.org/newscenter/news/2011/fukushima120411.html 21 http://www.nytimes.com/2011/04/12/world/asia/12japan.html?_r=4 22 The NRC granted license extension to Vermont Yankee on March 21, 2011, and to Palo Verde Units 1, 2, and 3 on April 21, 2011. http://www.nrc.gov/reactors/operating/licensing/renewal/applications.html
8 with confidence that the U.S. plants continue to operate safely. And at a May 4 House Energy
& Commerce Committee Hearing, NRC Chairman Greg Jaczko said As early as late summer, the commission may conduct the first mandatory hearings on new reactor licenses since the 1970s.
This report provides a summary of some of the most egregious failings of previously adopted NRC safety regulations to protect against the vulnerabilities exposed by the Japanese melt-down, as well as the limitations in the steps NRC has taken to date to explore these vulnerabilities in the U.S.
9 Emergency Diesel Generators: Decades of Reliability and Maintenance Problems It is not just earthquakes that can lead to the loss of the external electricity supply at nuclear power plants. In the U.S., such outages have also been caused by squirrels23 and hot weather,24and have also occurred at nuclear power plants. In 1990, a fuel truck accidentally backed into a power line at the Vogtle nuclear power plant, knocking out electricity; as with the Fukushima nuclear power plants, it turned out that the plants emergency diesel generation was also disabled.25 In the U.S., nuclear power plants are required to have emergency diesel generators with sufficient fuel to last 7 days, and battery capacity that can further run for 4-8 hours (depending on the reactor) in the event the diesel generators fail. While emergency diesel generators in the U.S. are required to be better protected than in Japan (they are typically required to be in hardened locations that are not vulnerable to tsunamis), an examination of NRC documents nevertheless indicates significant and prolonged problems associated with their operation.
On January 25, 1989, the NRC issued an information notice26 to alert addressees to events involving breaks or cracking of small-diameter tubing which can render emergency diesel generators (EDGs) inoperable. On August 6, 2007, NRC issued an Information Notice entitled Recurring Events Involving Emergency Diesel Generator Operability27, which describes some failures of emergency diesel generators that took weeks to resolve and referenced the 1989 notice. However, the document also stated that no specific action or written response was required.
A review of NRC documents indicates that here have been recurrent prolonged malfunctions of emergency diesel generators at nuclear power plants in the U.S. (see Table 2).
In the past eight years there have been at least 69 reports of emergency diesel generator inoperability at 33 nuclear power plants. A total of 48 reactors were affected, including 19 failures lasting over two weeks and 6 that lasted longer than a month.
A weeks-long failure of the emergency diesel generators leaves these nuclear power plants with only 4-8 hours worth of secondary emergency battery-powered generation in the event of a loss of offsite electricity. And even these minimal requirements do not apparently apply to spent nuclear fuel pools at nuclear reactors whose cores have been emptied of fuel assemblies. It is clear that the NRC has historically done little to address long-standing and serious problems associated with licensee maintenance of emergency diesel generators that leaves reactors vulnerable to a loss of offsite power.
23 http://www.usatoday.com/news/nation/2007-03-11-suicide-squirrels_N.htm 24 http://www.cbsnews.com/stories/2006/07/26/national/main1836674.shtml 25 http://www.nrc.gov/reading-rm/doc-collections/gen-comm/info-notices/1990/in90025s1.html 26 http://www.nrc.gov/reading-rm/doc-collections/gen-comm/info-notices/1989/in89007.html 27 http://pbadupws.nrc.gov/docs/ML0717/ML071760544.pdf
10 Spent Nuclear Fuel: Regulatory Loopholes
Background:
All U.S. nuclear plants store most of their highly radioactive spent nuclear fuel under water in pools, as was the practice at Fukushima Daiichi. Thirty-two General Electric Boiling Water Reactors locate their spent fuel storage pools on top of the reactor cores, as at Fukushima28. In Pressurized Water Reactors, spent fuel storage is typically below grade, meaning below ground level29. The water in these pools, which is cooled via circulation using pumps that require electricity, keeps the spent fuel rods from igniting, burning off their zirconium cladding, and releasing the vast quantities of radiation they contain.
The NRC has granted many reactor licensees permission to increase the amount of spent fuel that can be stored in these pools.30 Spent nuclear fuel pools in this country are filled nearly to overflowing in some cases - for example, the NRC gave the Pilgrim nuclear power plant permission to pack almost 4,000 spent fuel assemblies (up from the 2,320 the NRC had previously allowed and the 880 the reactor was originally designed to hold31) into its spent nuclear fuel pool, which, like the Fukushima Daiichi reactors, is located on top of the unit32. The tight packing of fuel rods at Pilgrim and many other spent fuel pools would make it more difficult to keep the rods cool, and increase the risk of radiation release, if cooling is lost or a spent fuel pool is damaged.
According to the Nuclear Energy Institute, there was 65,193 metric tons of spent fuel stored at nuclear plant sites across America in December 2010. Of this amount, 49,620 metric tons resided in spent fuel pools while 15,573 metric tons had been transferred to dry cask storage. By comparison, the reactor core of a large nuclear power reactor contains around 200 metric tons of irradiated fuel. Theres more than twice as much irradiated fuel in Americas spent fuel pools as in the reactor cores of all the nations operating reactors.
In Fukushima, the spent nuclear fuel pool associated with the unit 4 reactor was particularly troublesome as the loss of electricity needed to power the cooling system caused the water in the spent fuel pools to heat up. Unit 4s spent fuel pool contained larger than normal quantities of fuel, because the reactor core for that unit was undergoing refueling at the time of the earthquake and all of the fuel had been off-loaded into the spent nuclear fuel pool. There has been speculation that the water in the spent fuel pool completely boiled off33 and that there was a subsequent fire, that there may have been a hydrogen explosion in that pool (something that had 28 http://www.ucsusa.org/nuclear_power/reactor-map/embedded-flash-map.html 29 http://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr0933/sec3/082r3.html 30 http://www.nrc.gov/waste/spent-fuel-storage/pools.html 31 Safety Evaluation By The Office Of Nuclear Reactor Regulation Supporting Amendment No. 33 To Facility Operating License No. DPR-35 Boston Edison Company Pilgrim Nuclear Power Station, Unit No. 1 Docket No. 50-293 32 http://www.gpo.gov/fdsys/pkg/FR-1994-06-21/html/94-15024.htm 33 http://www.nytimes.com/2011/03/17/world/asia/17nuclear.html
11 never before been contemplated for spent fuel pools)34, and that the structure of the pool itself may have been damaged by either the earthquake or the explosion (because water that is being sprayed into the pool is evidently disappearing faster than it should if it were merely being boiled off)35.
Storing spent nuclear fuel in pools is not as safe as storing it in dry cask storage. Moving fuel into dry cask storage means fewer spent fuel rods remain in the pools, giving workers more time to cope with a loss of cooling power or loss of water from the pool, because fewer rods means less heat generated by the radioactive materials and thus a longer time for the water to heat up and boil away. Less fuel in the pool also allows for more water flow and better cooling for each fuel rod, and, even in the event of a loss of cooling function or water, less fuel also means a lower probability of a spent fuel fire and radiation release.
The safety benefits of dry cask storage were also noted in 2006, when the National Academy of Sciences issued a report36 that described the following comparative advantages of dry cask storage over spent fuel pools:
- Less spent fuel is at risk in an accident or attack on a dry storage cask than on a spent fuel pool.
- The potential consequences of an accident or terrorist attack on a dry cask storage facility are lower than those for a spent fuel pool.
- The recovery from an attack on a dry cask would be much easier than the recovery from an attack on a spent fuel pool.
Then-NRC-Commissioner and now-Chairman Greg Jaczko has also articulated this view, stating in 2008 that the most clear-cut example of an area where additional safety margins can be gained involves additional efforts to move spent nuclear fuel from pools to dry cask storage.
He went on to call for a rulemaking, stating that in an effort to be ever vigilant about the safety of spent fuel, I believe the NRC should develop new regulations which require spent fuel be moved to dry cask storage after it has been allowed to cool for five years.37 Despite this call for added safety measures to be implemented, no steps have been taken by the NRC to do so.
Earthquakes and Spent Fuel Pool Integrity The Fukushima Daiichi power remains in peril from further aftershocks, and is months from being fully under control. The fragility of the situation was highlighted when Fukushima Prefecture experienced a major aftershock of magnitude 7.0 on April 11. The aftershock forced the temporary evacuation of workers, and loss of power and water injection to units 1, 2, and 3 34 http://www.iaea.org/press/?p=1248 35 http://www.latimes.com/news/nationworld/world/la-fg-japan-quake-wrapup-20110318,0,2262753.story 36 http://www.nap.edu/catalog.php?record_id=11263 National Research Council. 2006. Safety and Security of Commercial Spent Nuclear Fuel Storage: Public Report. P. 68-70.
37 http://www.nrc.gov/reading-rm/doc-collections/commission/speeches/2008/s-08-023.html
12 for 50 minutes38 With visible structural damage to the unit 4 spent fuel pool, which lacked a roof as of March 17 following fires in the pool on March14th and 15th, there remain concerns that additional earthquakes or aftershocks could result in further damage to the spent fuel pools.39 In California, earthquakes have also caused heavy water losses from sloshing at spent fuel storage pools there, partly because the pools are located high in reactor buildings as they are at Fukushima40.
Concerns have about spent fuel integrity have previously been raised in the United States, focusing primarily on the threat that terrorists could pose to spent fuel storage. In June 2006, the NRC lost a Ninth Circuit Court case to the San Luis Obispo Mothers for Peace, which had sued to require consideration of the environmental impacts of a terrorist attack on the Diablo canyon nuclear power plant spent fuel storage facility. Instead of requiring these assessments to be performed nationwide, the NRC chose instead to abide by it only within the Ninth Circuit Court, which excludes the Central and Eastern states where most nuclear facilities are found. In June 2006, the Commonwealth of Massachusetts Attorney General sent the NRC a petition to amend its regulations to require Environmental Impact Statements for all nuclear power plant licensing decisions to consider the vulnerabilities of spent fuel storage pools nationwide, and sent a second petition on May 2, 2011 to suspend NRCs evaluation of the relicensing application for the Pilgrim nuclear power plant until the NRC has considered the spent fuel storage safety issues raised by Fukushima41. The NRC has not taken either requested action.
Spent Nuclear Fuel Pools Contain No Protections from Hydrogen Explosions Hydrogen can be produced in several ways during a nuclear reactor accident. One likely scenario at Fukushima is that under extreme heat, as the cooling systems lost power and fuel rods overheated, the zirconium cladding around the fuel rods reacted with water. This metal-water reaction gives off oxygen, and hydrogen, which is flammable. If the hydrogen is not removed, its build-up can lead to explosions that can further damage the reactor buildings and cause further radiation releases.
Protections against hydrogen explosions in the U.S. began when there was a hydrogen explosion, and threats of much greater explosions due to hydrogen buildup, during the 1979 Three Mile Island accident42. In 1981, NRC issued rules requiring nuclear power reactors to monitor hydrogen levels in the containment structure, and to have hydrogen recombiners (which act to combine hydrogen and oxygen to produce water before an explosion occurs) and/or vents (different reactor designs require different hydrogen mitigation technologies) to prevent hydrogen buildup,43 although these rules are not themselves adequately enforced or implemented.
38 http://www.jaif.or.jp/english/news_images/pdf/ENGNEWS01_1302521667P.pdf 39 http://www.iaea.org/newscenter/news/2011/tsunamiupdate01.html 40 http://www.nytimes.com/2011/03/18/world/asia/18spent.html 41http://www.mass.gov/?pageID=cagopressrelease&L=1&L0=Home&sid=Cago&b=pressrelease&f=2011_05_02_pi lgrim_nrc&csid=Cago 42 http://www.threemileisland.org/downloads/188.pdf 43 http://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr0737/final/sr0737.pdf
13 However, there are no requirements whatsoever for hydrogen mitigation technologies to be included at spent nuclear fuel pools44, presumably because hydrogen explosions were never previously contemplated for these facilities. On March 1545, an explosion at the Unit 4 spent fuel pool is thought to have occurred, clearly illustrating this particular spent nuclear fuel vulnerability.
There is No Regulatory Requirement for Some Spent Nuclear Fuel Pools to Have Emergency Power Capability As has been previously noted, the loss of cooling function which was caused by the loss of external electricity and subsequent failure of all the emergency diesel generators and batteries at Fukushima led to both the core meltdowns and the radiation releases (and fires and potential hydrogen explosions) at the Fukushima nuclear power plant.
A review of the NRCs Standard Technical Specifications for nuclear power plants46 indicates that spent fuel pools at nuclear reactors whose cores do not contain nuclear fuel (for example, because they were in the process of being refueled) do NOT require the presence of operable secondary emergency generation capacity. Thus, the circumstances that led to Japans Unit 4 fire, potential explosion and radiation release would apparently be in compliance with NRCs requirements.
Additionally, Rep. Markeys staff has learned that licensees often perform maintenance on their emergency diesel generators when the reactors are undergoing refueling outages47. For example on November 11, 2009, the Wolf Creek Nuclear Operating Corporation submitted a report to the NRC regarding a loss of external operating power that occurred during a 2009 refueling of the Wolf Creek nuclear power plant in Kansas while one of the emergency diesel generators was also undergoing maintenance.
This regulatory loophole clearly represents an unacceptable risk to the safety of any decommissioned nuclear reactor or any reactor currently undergoing refueling.
44 Response of Mr. Martin J. Virgilio, NRCs Deputy Executive Director for Reactor and Preparedness Programs, to questions from Rep. Markey at an April 6, 2011 hearing of the Oversight and Investigations Subcommittee hearing of the House Energy and Commerce Committee.
45 http://www.world-nuclear-news.org/RS_Attempts_to_refill_fuel_ponds_1703111.html 46 See for example Standard Technical Specifications General Electric Plants, BWR/4 and Standard Technical Specifications for Westinghouse Plants 47 Private communications from an individual working inside an operating nuclear power plant obtained by Rep.
Markeys office and discussions with nuclear safety experts.
14 Hydrogen Explosions: NRC Regulations Are Lacking, and NRC Officials Have Made Misleading Statements Related to their Use As noted, it is likely that hydrogen was generated at the Fukushima nuclear power plant when the zirconium cladding around the fuel rods reacted with water as they heated up. This metal-water reaction gives off oxygen, and hydrogen, which is flammable, and as the hydrogen concentrations built up the two gases likely then combined and exploded. Hydrogen explosions then blew apart the outer containments of the Units 1 and 3 reactors of the Fukushima Daiichi reactors, Unit 2s reactor containment was also damaged by an explosion (though its source is less clear), and the Unit 4 spent nuclear fuel pool is also likely to have experienced a hydrogen explosion48.
After the 1979 Three Mile Island accident,49 which involved a hydrogen explosion, the NRC issued rules requiring nuclear power reactors to monitor hydrogen levels in the containment structure, and to include technologies to mitigate hydrogen build up as it occurred.
The NRC rules for hydrogen control differed for various classes of reactor designs. Boiling Water Reactors (BWRs) were required to have vents, which allow hydrogen gas to be purged from the containment. For BWR Mark I and Mark II reactor designs, licensees were also required to pump the primary containment full of the inert gas, nitrogen, instead of air50. As a hydrogen explosion will not occur in the absence of oxygen, this inerting of the primary containments is a way of preventing them. For BWR Mark III and for Pressurized Water Reactors with smaller containments, a 1985 rule required plants to have the means to control the hydrogen produced if 75% of the fuel cladding reacted with water. The means to accomplish this was not specified; some plants have igniter systems that would burn off hydrogen before it could build up, and others have hydrogen recombiners that combine hydrogen with oxygen to form water before an explosion occurs.
However, almost immediately after issuing these rules to prevent hydrogen explosions, NRC began to relax them in response to pressure from industry. In 1984, the NRC agreed that BWR Mark I Owners Group, had demonstrated that Mark I reactors do not need vent and purge systems for hydrogen because they are inerted51. Pressurized Water Reactors with large containments were determined in 1989 to not need any hydrogen controls, because NRC decided the size of the containment could contain all of the hydrogen that could possibly be generated.
Finally, in 2003 NRC granted a request made by the Nuclear Energy Institute to eliminate the requirements for hydrogen recombiners and hydrogen and oxygen monitors.
NRC invoked two conflicting arguments to justify relaxing safety classifications for hydrogen controls. First, the NRC concluded that hydrogen release poses a minimal risk of causing a radiation release, stating that this hydrogen release is not risk-significant because the design-basis loss of cooling accident hydrogen release does not contribute to the conditional 48 http://www.jaif.or.jp/english/news_images/pdf/ENGNEWS01_1304997042P.pdf 49 http://www.threemileisland.org/downloads/188.pdf 50 http://www.nrc.gov/reading-rm/doc-collections/nuregs/staff/sr0933/sec2/a48r1.html 51 http://www.nrc.gov/reading-rm/doc-collections/gen-comm/gen-letters/1984/gl84009.html
15 probability of a large release up to approximately 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> after the onset of core damage52.
Secondly, the NRC concluded that these systems were ineffective at mitigating hydrogen releases from risk-significant beyond design-basis accidents (DBAs). As NRC spokesman Eliot Brenner said more plainly on March 31, 2001,53 They werent needed for design basis accidents and they didnt help with severe accidents. The result of this tortured logic was that NRC has allowed plants to remove a requirement for hydrogen mitigation technologies from their Technical Specifications. Some reactors may still have these features installed, but they are not required to keep them operational.
Yet despite the absence of these regulatory requirements in the U.S., the NRC has consistently made inaccurate statements that the Fukushima Daiichi reactors did not have hardened vents that could have prevented hydrogen explosions, and that in the U.S, such features were required. For example, at a March 21 hearing at the NRC,54 Bill Borchardt, Executive Director for Operations for the NRC stated, in response to a question regarding what measures were in place at U.S. reactors to mitigate hydrogen explosions: Well, the hardened vent, of course -- the U.S. design approach is to protect the containment... So it's at least my belief that you wouldn't have the hydrogen accumulation in the upper levels of the reactor building, which we believe is the cause of the explosions at Fukushima Daiichi.
These claims were repeated on April 6 at a hearing before the House Energy &
Commerce Committee, when Martin J. Virgilio, NRCs Deputy Executive Director for Reactor and Preparedness Program, stated that The U.S. nuclear industry has implemented a number of equipment upgrades post 9/11 including hardened vents to prevent hydrogen explosions and systems that allow for reactor cooling and blackout conditions One of the most significant features I would say that has been installed on those Mark I containments is what we called a hardened vent, and that allows the release of hydrogen gas that has built up inside the containment to be vented out safely. As we saw in Fukushima, there were a number of explosions which we are assuming related to that hydrogen gas buildup. Had they had the hardened vent or had they used the hardened vent, this would not have been an issue.
According to an April 5 email55 sent by NRC staff to the staff of Congressman Edward J. Markey, the Fukushima Daiichi reactors did have hardened vents. Moreover, under questioning by Congressman Markey, Mr. Virgilio also acknowledged that the regulatory requirement for the operability of these vents had been removed, that no such requirements had ever been in place for spent nuclear fuel pools, and that many such systems require electricity to operate.
Clearly, the NRC must revisit its decision not to require technologies for the mitigation of the build-up of hydrogen to be installed and operational on both reactor and spent nuclear fuel pool containment.
52 http://www.nrc.gov/reactors/operating/licensing/techspecs/techspecs-pdf/447r1frn.pdf 53 http://green.blogs.nytimes.com/2011/03/31/u-s-dropped-nuclear-rule-meant-to-avert-hydrogen-explosions/
54 http://www.nrc.gov/reading-rm/doc-collections/commission/tr/2011/20110321.pdf 55 http://markey.house.gov/docs/4-6-11markey_e-mail_2_-nrc_question_regarding_fukushima_unit_2.pdf
16 Seismic Safety: NRC Has Not Factored Modern Geologic Information Into Reactor Safety
Background:
The United States has many areas with the potential for strong seismic activity in the coming decades56. California has a historical record of 8 earthquakes of magnitude 7.3 or greater since 1700, including earthquakes close to both the Diablo Canyon and San Onofre nuclear power plants.57 In 1700, the Cascadia subduction zone, which stretches offshore from British Columbia to Northern California, caused a 9.0 earthquake58. New research on underwater landslides caused by past Cascadia megaquakes shows that the average time between such events over the past 10,000 years is 240 years. The next earthquake is therefore overdue, and according to research led by University of Oregon geologist Dr. Chris Goldfiner, there is a 37% percent chance of a magnitude-9 quake over the next 50 years59. In the Southeast, Charleston, S.C. had a 7.3 earthquake in 1886. The New Madrid seismic zone, which includes southeastern Missouri, northeastern Arkansas, western Tennessee, western Kentucky and southern Illinois, produced a magnitude 7.7 earthquake in Arkansas in 181160.
Eight nuclear power reactors are in the seismically active West Coast, approximately 27 are near the New Madrid seismic zone, and 5 are in earthquake-prone South Carolina (see Figure 1).61 The 2011 report of the Independent Expert Panel on the New Madrid seismic zone notes:
The estimated hazard in the New Madrid region will evolve because of further analysis and better data. NRCs regulations must also continually evolve in response to scientists understanding of seismic hazard62.
According to NRCs website, Today, the NRC utilizes a risk-informed regulatory approach, including insights from probabilistic assessments and traditional deterministic engineering methods to make regulatory decisions about existing plants. Historical data from a reactors site is used to determine design basis loads from the areas maximum credible earthquake, with an additional margin included. But in the past 60 years, since the beginning of the commercial nuclear power industry, geologists have learned more about the likelihoods of earthquakes occurring throughout the country. For example, the geologic field of plate tectonics, which explains how the plates of the Earths crust move against each other, only emerged in the 1960s, after many nuclear power plants had already been sited.63 56 http://earthquake.usgs.gov/hazards/products/graphic2pct50.jpg 57 http://earthquake.usgs.gov/earthquakes/states/10_largest_us.php 58 http://earthquake.usgs.gov/research/structure/crust/cascadia.php 59 http://www.nature.com/news/2010/100531/full/news.2010.270.html 60 http://earthquake.usgs.gov/earthquakes/states/events/1811-1812.php 61 http://earthquake.usgs.gov/hazards/products/conterminous/2008/maps/us/3hzSA.usa.jpg 62 http://earthquake.usgs.gov/aboutus/nepec/reports/NEPEC_NMSZ_expert_panel_report.pdf 63 http://www.ucmp.berkeley.edu/geology/techist.html
17 Figure 1: Operating Nuclear Power Plants vs Horizontal Ground Acceleration Percent of Gravity64 Case Study: Diablo Canyon Even when presented with the discovery of previously unknown dangers, the NRC has typically assumed that plants remain safe. An example of this can be seen from the Diablo Canyon Nuclear Power Plant, whose application to be relicensed for another twenty years, until 2044 and 2045 respectively for the two units, is currently pending before the Commission.65 Located 12 miles from San Luis Obispo, California, the nuclear power plant first became controversial in 1971, when the Hosgri Fault Zone was discovered 3 miles away from Diablo Canyon, requiring PG&E to spend $4.4 billion on re-engineering (double what it had been expected to cost, as the first set of retro-fits were improperly conducted). According to the Southern California Earthquake Data Center, the Hosgri Fault may have been the location for a 7.1-magnitude earthquake that occurred in 1927.66 64 Map constructed by the Congressional Cartography Program, Geography and Map Division, Library of Congress 65 http://www.nrc.gov/reactors/operating/licensing/renewal/applications/diablo-canyon.html#appls 66 http://www.data.scec.org/chrono_index/lompoc.html
18 Despite Diablo Canyon being three miles from an earthquake fault-line, the NRC concluded in 1984 that the probability of an earthquake causing a radiation release at Diablo Canyon, or happening at the same time as a radiation release, has too low a probability to warrant mandatory consideration.67 This NRC belief, which has been emphatically refuted by the Japanese meltdowns, has been used by courts to deny requests for additional safety measures to be installed there.68 The NRC has also made the surprising conclusion that the Diablo Canyon area was at most one of moderate seismicity, an assertion based on data drawn from 1950 to 197469. The NRC has thus far accepted Pacific Gas and Electrics argument that the Diablo Canyon Power Plant remains safe despite the 2008 discovery of a new fault called the Shoreline Fault about 1 km from Diablo Canyon which extends to the Hosgri Fault, and the NRC has estimated this fault as being capable of leading to a maximum magnitude 6.85 earthquake70. According to the NRC, the Diablo Canyon nuclear power plant is rated for a 7.5-magnitude earthquake from the Hosgri fault.71 Yet the assessment by the Southern California Earthquake Center is that there is a 46%
probability of California having an earthquake of magnitude 7.5 or greater in the next 30 years, and this assessment is based on conservative analysis that excludes the possibility of an earthquake in the Cascadia subduction zone that could be even more catastrophic72.
Following calls for a halt to the NRCs consideration of the license extension application for Diablo Canyon73 in the wake of the Japanese meltdown, on April 11, Pacific Gas and Electric (PG&E) issued a press release indicating that it had requested a delay in its approval until the accelerated completion of new 3-dimensional seismic studies,74 and issued a press release indicating that it had requested a delay in its approval until such studies were completed75.
However, this appears to be a hollow commitment. What PG&E actually requested was for the NRC to delay the final processing of the license renewal application such that the renewed operating licenses, if approved, would not be issued until after PG&E has completed the 3-D seismic studies and submitted a report to the NRC addressing the results of those studies76.
67 NRC Decision CLI-84-12. In the Matter of Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant Units 1 and 2. Docket Nos. 50-275 OL, 50-323 OL.
68 San Luis Obispo Mothers for Peace v. Nuclear Regulatory Commission.
http://www.elawreview.org/summaries/environmental_quality/nepa/san_luis_obispo_mothers_for_pe.html 69 Nuclear Regulatory Commission Document CLI-84-12, In the Matter of Pacific Gas and Electric Company (Diablo Canyon Nuclear Power Plant Units 1 and 2). p. 8.
70 Research Information Letter 09-001: Preliminary Deterministic Analysis of Seismic Hazard at Diablo Canyon Nuclear Power Plant from Newly Identified Shoreline Fault, p. 8. Available in ADAMS (http://www.nrc.gov/reading-rm/adams/web-based.html), by entering ML090330523.
71 NRC. Safety Evaluation Report With Open Items Related to the License Renewal of Diablo Canyon Nuclear Power Plant, Units 1 and 2, Docket Nos. 50-275 and 50-323. January 2011. Available in ADAMS (http://www.nrc.gov/reading-rm/adams/web-based.html), by entering ML110100796 72 http://www.scec.org/core/public/sceccontext.php/3935/13661 73 See for example, http://www.scpr.org/news/2011/03/24/congresswoman-wants-diablo-canyon-relicensing-put-/
74 http://www.pge.com/about/newsroom/newsreleases/20110411/pgampe_commits_to_finishing_3-d_seismic_studies_related_to_diablo_canyon_before_seeking_final_issuance_of_renewed_licenses.shtml 75 http://www.sanluisobispo.com/2011/04/11/1558606/pge-asks-for-delay-in-license.html 76 PG&E Letter DCL-11-047. Request for Deferral of Issuance of Diablo Canyon Power Plant Renewed Operating Licenses. April 10, 2011.
19 Since the NRC has already completed a draft Safety Evaluation Report on the renewal application, the gesture by PG&E appears to be meaningless, since it is not requesting that NRC reevaluate the application based on the results of these forthcoming studies. PG&E simply wants people to feel the added assurance of the plants seismic integrity that they appear certain will emerge from the forthcoming advanced seismic research.
Seismic Concerns: Not just at West Coast reactor sites It is not just West Coast nuclear power plants that have long been the subject of seismic examination that require a regulatory review. In 2010, the NRC used 2008 seismic risk data from the U.S. Geological Survey (USGS) and measures of the fragility of each reactor to conclude that the risks of core damage from earthquakes in the Eastern and Central States are greater than previously estimated. But the NRC has not taken steps to use this information in regulation.77 Core damage due to earthquake is expected to occur 0.0001 times per year at the Indian Point 3 reactor, according to NRC analysis based on 2008 seismic data from the United States Geological Survey78. The NRC is currently reviewing a license extension application for Indian Point79. This core damage estimate is 72% higher than the estimate that was based on seismic data from 1989. Indian Point is about 25 miles from New York City. Pilgrim Nuclear Power Station, about 38 miles from Boston and for which there is also an application for a twenty year license extension pending before the Commission80, is estimated to suffer 0.000069 core damage events per year due to earthquakes. The NRCs risk estimate for Pilgrim is up more than 7 times (763%) from the estimate that was based on 1989 seismic hazard information.
The average number of core damage events for each reactor due to earthquakes, based on 2008 seismic data, is 0.000013 per year, according to an analysis of NRC data performed by MSNBC.81 Based on 1989 seismic data, by contrast, the expected number of core damage events is 0.0000038. While both of these are small numbers, the estimated risk has more than tripled based on the more current understanding of seismology. The NRCs analysis also notes that it lacks detailed information regarding the physical vulnerability of nuclear power plants to earthquakes for about one third of reactors.
77 Generic Issue 199 (GI-199): Implications of updated probabilistic seismic hazard estimates in Central and Eastern United States on existing plants: Safety/Risk Assessment. August 2010. Available from NRC at http://www.nrc.gov/reading-rm/adams/web-based.html under accession number ML100270598.
78Generic Issue 199 (GI-199): Implications of updated probabilistic seismic hazard estimates in Central and Eastern United States on existing plants: Safety/Risk Assessment. August 2010. Appendix D, Table D-1: Table D-1: Seismic Core-Damage Frequencies Using 2008 USGS Seismic Hazard Curves. This is the value for the weakest link model. Available by searching for document ML100270756 in ADAMS: http://www.nrc.gov/reading-rm/adams/web-based.html 79 http://www.nrc.gov/reactors/operating/licensing/renewal/applications.html 80 http://www.nrc.gov/reactors/operating/licensing/renewal/applications/pilgrim.html 81 http://www.msnbc.msn.com/id/42103936/ns/world_news-asia-pacific/ The MSNBC report used data from NRC document ML100270756, which is available by searching ADAMS: http://www.nrc.gov/reading-rm/adams/web-based.html. The NRC document contains seismic hazard estimates for 96 reactors; the NRC provided MSNBC estimates for the remaining 8 reactors. The data published by MSNBC appear to correspond to the NRCs weakest link model.
20 The higher risks to reactors from earthquakes were so clear to the NRC staff who performed this Safety/Risk Assessment that they recommended further action be referred to the Office of Nuclear Reactor Regulation for regulatory office implementation, and that this office take further actions to address GI-199 outside the [General Issues Program] (i.e. obtain information and develop methods, as needed, to complete plant-specific value-impact analyses of potential backfits to reduce seismic risk).82 Of course, any core damage event at a U.S. nuclear reactor would be of grave concern, and thus it is important to examine the potential frequency of such disasters caused by earthquakes across the entire fleet of nuclear reactors. Based on the expected number of events per year estimated for each nuclear reactor, we can sum the total number of expected core damage events per year for the nations fleet as a whole. According to calculations performed by the staff of Congressman Markey, the expected number of core damage events per year, across all the nuclear power plants in the country, is 0.0013.83 The threat of a nuclear disaster due to an earthquake is a long-term threat, because nuclear reactors operate for many years. Nuclear power reactors were originally licensed to operate for 40 years. The NRC has issued 20 year extensions to the operating licenses for 19 nuclear reactors since the beginning of 200784, and is reviewing applications for 16 more such extensions, including applications for Indian Point and Pilgrim, the nuclear power plants in the central and eastern U.S. the NRC staff deemed to be most at-risk of core damage from earthquakes85. If the U.S. continues to have the same set of nuclear power plants over the next twenty years, the expected number of core damage events due to earthquakes is the per-year frequency times twenty, or 0.026, across the entire twenty year interval. This estimated national frequency of reactor core damage due to earthquakes does not factor in the additional hazards due to events that are independent of earthquakes, such as strong storms, wind, fires, operator error, reactor aging issues (for example, failures due to the corrosion of buried pipes that transport both cooling water and fuel to the emergency diesel generators and submerged cables),
or terrorism.
82 Safety/Risk Assessment Results for Generic Issue 199, Implications of Updated Probabilistic Seismic Hazard Estimates in Central and Eastern United States on Existing Plants. August 2010.
83 Staff took the sum of these core damage probabilities for each of the 65 nuclear power plant sites. Many nuclear power plant sites contain more than one nuclear reactor, and staff made the assumption, borne out by the Fukushima Daiichi melt-down, that the reactors that are co-located at a single nuclear power plant site are not independent; rather, they tend to be affected similarly by an earthquake. Additionally, they may impact one another as events unfold (explosions at one unit at Fukushima have been speculated to have damaged other units). For nuclear power plants with multiple reactors, the value chosen was that for the reactor with the highest core damage frequency as estimated by the NRC.
84 Reactors given license renewals by NRC from 2007 to the present, and the States that host them: Palisades (MI);
James A. FitzPatrick (NY); Wolf Creek, Unit 1 (KS); Harris, Unit 1 (NC); Oyster Creek (NJ); Vogtle, Units 1 and 2 (GA); Three Mile Island, Unit 1 (PA); Beaver Valley, Units 1 and 2 (PA); Susquehanna, Units 1 and 2 (PA); Cooper Nuclear Station (NE); Duane Arnold Energy Center (IA); Kewaunee Power Station (WI); Vermont Yankee Nuclear Power Station (VT); Palo Verde, Units 1, 2, and 3 (AZ).
http://www.nrc.gov/reactors/operating/licensing/renewal/applications.html 85 Pilgrim 1, Unit 1 (MA); Indian Point, Units 2 and 3 (NY); Prairie Island, Units 1 and 2; Crystal River, Unit 3 (FL); Hope Creek (NJ); Salem, Units 1 and 2 (NJ); Diablo Canyon, Units 1 and 2 (CA); Columbia Generating Station (WA); Seabrook Station, Unit 1 (NH); Davis-Besse Nuclear Power Station, Unit 1 (OH); South Texas Project, Units 1 and 2 (TX). http://www.nrc.gov/reactors/operating/licensing/renewal/applications.html; http://www.nrc.gov/info-finder/reactor/
21 Finally, the NRC has also failed to consider the impacts of multiple threats striking simultaneously because the NRCs regulations do not require them to. The Fukushima nuclear power plant was struck not only by the earthquake, but by its direct consequences, including a tsunami, fires, total station blackout due to loss of offsite power and damage to emergency diesel generators, overtaxed emergency responses resources due to crises elsewhere, and the inability to bring equipment to the site because of debris. Even the nuclear industry has recognized this assumption is flawed: What clearly has shown up in Japan is multiple, stacked events. Weve not analyzed for all those things, said Preston D. Swafford, the Tennessee Valley Authoritys chief nuclear officer.86 86 http://www.nytimes.com/2011/03/27/us/27reactor.html?_r=1
22 NRCs Post-Fukushima Efforts: Scope Limitations and Secrecy Concerns On March 23, the NRC voted to require a multi-phase review87 of U.S. nuclear reactor safety in the wake of the Japanese meltdown. The near-term review portion of these efforts called for the establishment of a task force to:
Evaluate currently available technical and operational information from the events that have occurred at the Fukushima Daiichi nuclear complex in Japan to identify potential or preliminary near term/immediate operational or regulatory issues affecting domestic operating reactors of all designs, including their spent fuel pools, in areas such as protection against earthquake, tsunami, flooding, hurricanes; station blackout and a degraded ability to restore power; severe accident mitigation; emergency preparedness; and combustible gas control.
The task force was additionally directed to develop near-term recommendations for regulatory and other changes, and is also required to inform its efforts using stakeholder input.
The longer (90 day) review is supposed to include more extensive stakeholder input, and the task force was directed in this phase to evaluate all technical and policy issues related to the event to identify potential research, generic issues, changes to the reactor oversight process, rulemakings, and adjustments to the regulatory framework that should be conducted by NRC. All of the results of these efforts were supposed to be made public.
The NRC recently initiated inspections at each nuclear power plant in order to assess the operational or regulatory issues that may have arisen as a result of the Fukushima meltdown, and that the reports associated with these inspections are supposed to be submitted by May 13.
According to reports received by Rep. Markey88, the NRC may be artificially constraining the scope of these investigations and may keep the results of most of these investigations secret. These constraints and limitations include the following:
- The NRC only allowed89 its inspectors 40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> in which to perform each inspection for nuclear power plants that contain one nuclear reactor. For nuclear power plants with more than one unit, inspectors are being provided with only 50-60 hours total in which to complete their work. By contrast, the Institute of Nuclear Power Operations (INPO) reportedly spent hundreds of hours performing their inspections.
- The NRC inspectors were initially told to limit their inspections to the adequacy of safety measures needed to respond to Design Basis Events. This meant that inspectors would be assessing licensees ability to withstand and respond only to events that have already been contemplated and analyzed by the NRC and for which regulatory 87 Tasking Memorandum - COMBJ-11-0002 - NRC Actions Following The Events In Japan 88 Private correspondence from an individual working inside an operating nuclear power plant obtained by Rep.
Markeys staff 89 See NRC Temporary Instruction 2515/183 Followup To The Fukushima Daiichi Nuclear Station Fuel Damage Event
23 requirements have been implemented, but not events such as the ones that occurred in Japan, which were previously believed to be impossible.
- After several NRC inspectors complained that it made no sense to limit the scope of the inspections to Design Basis Events, the guidance was changed to enable inspectors to look beyond them, and explicitly includes an examination of the measures that were implemented following the terrorist attacks of September 11, 2011 (some of which could help mitigate against some of the problems that occurred in Japan); however, they were also explicitly told not to record any of their beyond Design Basis observations or findings in documents that would be made public as part of the Commissions review or public report(s). Instead, these findings would be entered into a private NRC database and kept secret.
- Inspectors were also told not to include matters in their reports that licensees had already identified. Since the INPO inspections were concluded before the NRC inspections began, none of the reportedly dozens of issues that were identified by INPO inspectors and reported to licensees will be included in the NRC inspection reports.
Although four of five NRC Commissioners, in response to questions from Congressman Markey, committed to a full investigation of all vulnerabilities and the public release of all non-security-sensitive findings at a May 4, 2011 hearing of the Energy and Commerce Committee90, the limitations imposed on NRCs inspectors appear to ensure that the full range of vulnerabilities of U.S. nuclear reactors to events that occurred in Japan will not be performed, or reported to the NRC or the public. The NRC needs to ensure that there is a full investigation of such vulnerabilities, and that all non-security sensitive findings and recommendations are made public.
90 Private communications from an individual working inside an operating nuclear power plant obtained after the May 4 hearing do not indicate that any changes to these inspections have occurred.
24 Table 1. National responses to Japanese nuclear disaster Following the accident at the Fukushima Daiichi nuclear power plant in Japan, many other countries have announced new safety measures with regards to nuclear reactors. China, Venezuela, Switzerland, Italy, Japan, and Taiwan have suspended new reactor development.
Germany and Japan announced it would shut down older reactors pending safety review.
Country Reactors Shut Down Halted New Reactors Reduced Future Nuclear Role Canada91 NO NO NO China92 NO YES YES France 93 NO NO NO Germany94 YES YES YES India95 NO NO NO Italy96 NO YES YES Japan97 YES YES YES Korea98 NO NO NO Philippines99 NO NO YES Russia100 NO NO NO Spain101 NO NO NO Switzerland102 NO YES NO Taiwan103 NO YES NO U.K.104 NO NO YES Venezuela105 NO YES NO 91 http://www.theglobeandmail.com/news/national/after-japan-canadas-nuclear-industry-girds-for-change/article1952403/
92 http://www.china.org.cn/business/2011-03/29/content_22244887.htm 93 http://www.bloomberg.com/news/2011-05-09/france-to-test-58-reactors-for-surviving-earthquakes-not-terrorist-attack.html 94http://af.reuters.com/article/energyOilNews/idAFLDE7300LY20110401?pageNumber=1&virtualBrandChannel=0 95 http://www.google.com/hostednews/afp/article/ALeqM5hzaU34a1I4qtZekAQw1owqlahu-Q?docId=CNG.76b96a556a95cbd54e43eeafb4c0a866.821 96 http://news.sciencemag.org/scienceinsider/2011/04/italy-puts-nuclear-power-on-indefinite.html?rss=1 97 http://www.washingtontimes.com/news/2011/mar/29/japan-vows-review-nuclear-safety-standards/
http://www.nytimes.com/2011/05/11/world/asia/11japan.html?_r=1 98 http://news.xinhuanet.com/english2010/world/2011-03/15/c_13780365.htm 99 http://news.yahoo.com/s/ap/20110316/ap_on_bi_ge/nuclear_energy_5 100 http://www.huffingtonpost.com/simon-saradzhyan/russia-nuclear-japan_b_839109.html 101 http://www.financebusinessnews.net/spain-orders-review-of-nuclear-power/
102 http://www.nytimes.com/2011/04/01/world/europe/01swiss.html 103 http://www.chinapost.com.tw/taiwan/national/national-news/2011/03/19/295239/Government-delays.htm 104 http://www.telegraph.co.uk/finance/newsbysector/energy/8393878/Chris-Huhne-Britain-may-scale-back-nuclear-plans-after-Japan-disaster.html 105 http://news.yahoo.com/s/ap/20110316/ap_on_bi_ge/nuclear_energy_5
25 Table 2 - Summary of Emergency Diesel Generator (EDG) Inoperability 2002-2010 To determine cases of EDG inoperability staff used the U.S. NRC Licensee Event Report (LER)
Search (https://lersearch.inl.gov). Staff searched between the dates 1/1/2002 and 5/1/2011 using keyword criteria "emergency diesel generators." Current reports are only available up to 3/15/2011. The search yielded 3102 total records. In order to determine which reports related to inoperable EDGs we used a word search for "diesel" and "EDG" in the title of LER record. The number of days inoperable was determined by either direct reporting of days inoperable in the LER record or simple subtraction between the dates when the EDG(s) were cited as inoperable.
Inoperability of under 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> was rounded up to 1 day.
In the past eight years there have been at least 69 reports of EDG inoperability at 33 nuclear power plants. A total of 48 reactors were affected, including 19 failures lasting over two weeks and 6 that lasted longer than a month.
Power plant Date Problem Days inoperable Id_number Wolf Creek 12/6/2010 Technical Specification Required Shutdown due to Inadequate Planning Resulting in Extended Emergency Diesel Generator Inoperability 8
4822010014 Byron 2 11/17/2010 Unit 2 Emergency Diesel Generator Inoperable for Longer than Allowed by Technical Specifications due to Inadequate Work 5
4552011001 Palo Verde 1 9/15/2010 Inoperable Emergency Diesel Generator due to Fuel Oil Transfer Pump Failure 3
5292010002 Brunswick 1 &2 9/13/2010 Emergency Diesel Generator Inoperable for Greater than Technical Specification Completion Time 1
3252010004 Robinson 2 6/24/2010 Emergency Diesel Generator Inoperable due to Inverter Failure 3
2612010005 Turkey Point 3 6/7/2010 Fuel Transfer Pump Failure Renders 3B Emergency Diesel Generator 45 2502010002 Turkey Point 4 5/10/2010 Damaged Speed Sensor Caused the 4A Emergency Diesel Generator to be Inoperable 16.9 25120100003 Robinson 2 4/26/2010 Clearance Error Results in the A Emergency Diesel Generator Becoming Inoperable 8
2612010004 Indian Point 2 3/13/2010 Inoperable Emergency Diesel Generators during Refueling Shutdown due to Inadvertent Isolation of Service Water Cooling Caused by Failure to Properly Verify the In-Service Cooling Header 1
2472010003 Robinson 2 2/22/2010 Emergency Diesel Generator Inoperable in Excess of Technical Specifications Allowed Completion Time 27 2612010001 Wolf Creek 10/22/2009 Loss of both Diesel Generators with all fuel in the Spent Fuel Pool 1
4822009005 Millstone 2 10/7/2009 Two Independent Diesel Generators Rendered Inoperable due to Cornmon Cause 1
3362009003
26 Brunswick 1 &2 9/20/2009 Technical Specification Required Shutdown Due To Emergency Diesel Generator 4 Inoperability 8
3252009004 Turkey Point 4 8/11/2009 4B Emergency Diesel Generator Inoperable Due to Air-bound Main Fuel Pump 14.3 2512009001 Oyster Creek 8/3/2009 EDG #1 Inoperable due to Failure of its Output Breaker to Close 2
2192009006 Fitzpatrick 7/7/2009 Inoperable Emergency Diesel Generators due to Degraded Voltage Timers 1
3332009007 Robinson 2 4/20/2009 Emergency Diesel Generator Inoperable in Excess of Technical Specifications Allowed Completion Time 3
2612009001 Prairie Island 2 2/16/2009 LER 2-09-01, Clearance Order Renders Opposite train Emergency Diesel Generator Inoperable 2
3062009001 Kewaunee 1/23/2009 Emergency Diesel Generators Inoperable Requiring Notice of Enforcement Discretion Unreported 3052009001 Palisades 10/9/2008 Emergency Diesel Generator Inoperable in Excess of Technical Specification Requirements 30 2552008007 Hope Creek 4/22/2008 Blown 1E Inverter Main Fuse With One Emergency Diesel Generator Inoperable Causes Loss Of Control Room Emergency Filtration Loss Of Safety Function 1
3542008002 Prairie Island 1 12/21/2007 Technical Specification Required Shutdown due to Both Emergency Diesel Generators Being Inoperable 3
2822007004 Columbia 12/10/2007 Inoperable Diesel Generator due to Inadequate Procedure That Caused Potential Transformer Fuses to Clear during Shut Down of the Diesel 83 3972007005 Comanche Peak 1 11/21/2007 Emergency Diesel Generator Inoperable for Longer Than Allowed by TS due to Paint on Metering Rod 1
4452007001 Prairie Island 2 10/8/2007 Emergency Diesel Generator Inoperable Longer than Allowed by Techincal Specifications Due to Loose Switch 35 3062007002 Cooper Station 9/11/2007 Procedural Guidance Leads to Rendering Second Diesel Generator Inoperable 9
2982007006 Palisades 7/25/2007 Emergency Diesel Generator Inoperable in Excess of Technical Specification Requirements 23 2552007006 Wolf Creek 7/8/2007 Emergency Diesel Generator Out of Service Longer than Technical Specification Allowed Outage Time 4
4822007001 Duane Arnold 4/11/2007 Condition Prohibited by Technical Specifications; B Emergency Diesel Inoperable 60 3312007008 Brunswick 1 &2 4/1/2007 Technical Specification Required Shutdown Due To Emergency Diesel Generator 4 Inoperability 10 3252007002 Fort Calhoun 2/16/2007 Inoperability of a Diesel Generator with an Inoperable Containment Cooling Fan from the Opposite Bus 1
2852007003
27 Peach Bottom 1 &
2 11/17/2006 Plant Modification Created Diesel Generator Building Carbon Dioxide Suppression Room Flooding Vulnerability Unreported 2772006004 Brunswick 1 &2 11/2/2006 Operations Prohibited by Technical Specifications due to Inoperable Emergency Diesel Generator 1 15 3252006007 Crystal River 3 11/1/2006 Emergency Diesel Generator in a Condition Prohibited by Technical Specifications due to Mispositioning 28 3022006002 Palo Verde 1,2,3 9/5/2006 Failure of Emergency Diesel Generator to Attain Required Voltage due to a Failed K1 Relay Contactor 18 5302006006 Seabrook 8/31/2006 Plant Shutdown due to Inoperable Emergency Diesel Generators 1
4432006006 Fermi 2 8/17/2006 Emergency Diesel Generators Out of Service due to Undersized Control Power Transformers 1
3412006004 Kewaunee 8/17/2006 Fuel oil leak on Swedgelock fitting renders Emergency Diesel Generator A inoperable 51 3052006009 South Texas 3/25/2006 Standby Diesel Generator Failed Surveillance Test Demonstrating Performance at 110% Load 3
4982006001 Calvert Cliffs 1 3/24/2006 Failure to adequately control design setpoints for feeder breaker supplying EDG support systems 1
3172006001 Prairie Island 2 2/5/2006 Unit 2 Shutdown Required by Technical Specifications due to Inoperable Emergency Diesel Generator 11 3062006001 River Bend 9/9/2005 Operation Prohibited by Technical Specifications due to Diesel Generator Malfunction 23 4582005003 Brunswick 1 &2 8/6/2005 Voluntary Report - Shutdown of Units 1 and 2 Due to Emergency Diesel Generator Operability Concerns Unreported 3252005006 San Onofre 3 6/26/2005 Emergency Diesel Generator (EDG) 3G003 Declared Inoperable due to Loose Wiring Connection on Emergency Supply Fan 1
3622005001 Cooper Station 6/21/2005 Both Diesel Generators Inoperable in Mode 4 Leads to Condition Prohibited by Technical Specifications 1
2982005003 Prairie Island 2 4/15/2005 Unit 2 Shutdown Required by Technical Specifications due to Inoperable Emergency Diesel Generator 14 3062005002 Crystal River 3 3/25/2005 Emergency Diesel Generator Inoperable due to Fuel Oil Header Check Valves Leaking Past Their Seats 30 3022005002 Perry 2/17/2005 All Emergency Diesel Generators Declared Inoperable due to Degraded Testable Rupture Discs 1
4402005002 Fort Calhoun 10/19/2004 Inoperable Diesel Generator for 28 Days Due to Blown Fuse During Shutdown 29 2852004002 Brunswick 1 &2 8/15/2004 Operation Prohibited by Technical Specifications due to Inoperable Emergency Diesel Generator 47 3252004003
28 Fermi 2 8/8/2004 Technical Specification Required Shutdown Due to Emergency Diesel Generator Failure 8
3412004001 North Anna 2 5/9/2004 Inoperable Emergency Diesel Generators Due to Shims for Exhaust Support Missing or Not Secured 1
3392004001 Crystal River 3 4/23/2004 Emergency Diesel Generator Inoperable Due To Fuel Oil Header Outlet Check Valve Leaking Past Seat 2
3022004002 Cooper Station 3/28/2004 Failure to Follow Procedure Results in Both Diesel Generators being Inoperable Unreported 2982004002 Cooper Station 3/23/2004 Both Diesel Generators Inoperable due to Voltage Regulator Design Results in Loss of Safety Function Unreported 2982006003 Browns Ferry 1,2,3 2/16/2004 Inoperability of Diesel Generator 3D Beyond TS Allowable Outage Time 24 2962004001 Brunswick 1 1/4/2004 Emergency Diesel Generator No. 3 Condition Prohibited by the Technical Specifications 29 32520040010 South Texas 2 12/9/2003 Standby Diesel Generator 22 Failure Unreported 4992003003 Waterford 3 9/29/2003 Failure of Emergency Diesel Generator A Fuel Oil Line 1
3822003002 Perry 8/20/2003 Unrecognized Diesel Generator Inoperability During Mode Changes 7
4402003003 LaSalle 1&2 4/23/2003 1A and 0 Diesel Generators Inoperable Simultaneously Due to Iinadvertent Partial CO2 Actuation 1
3732003002 Cooper Station 2/28/2003 Inadequate Communication Results in Both Diesel Generators Inoperable Simultaneously 1
2982003001 Kewaunee 2/26/2003 Shutdown Initiated - Diesel Generator Failed Start Test - Unusual Event - Caused by Start Relay Failure 2
3052003002 Columbia 2/16/2003 Failure to Restore Emergency Diesel Generator Within TS Completion Time and Subsequent Plant Shutdown 14 3972003006 Catawba 1 & 2 2/12/2003 Loss of Safety Function Due to Inoperability of the 2B Diesel Generator Upon Loss of Vital Inverter 2EID with the 2A Diesel Generator Inoperable 1
4132003002 Indian Point 2 10/9/2002 Two of Three Emergency Diesel Generators Inoperable Due to Component Failures; a Condition Prohibited by Tech Specs 2
2472002006 Catawba 1 6/24/2002 Technical Specification Noncompliance -
Inoperable Diesel Generator Caused by Inadequate Wire Lug Crimping at Closing Spring Motor Disconnect Switch 5
4132002006 Calvert Cliffs 2 1/24/2002 Pump Flexible Drive Gear Wear Causes Emergency Diesel Generator Inoperability 7
3182002001