NRR E-mail Capture - Request for a List of Documentation to Determine There Are No CASS ASME III Class 1 Valve Less than Four Inches Installed at Columbia
ML11137A043
Person / Time
Site: Columbia Energy Northwest icon.png
Issue date: 05/12/2011
From: Mostala A
Energy Northwest
To: Cunanan A
Division of License Renewal
References
Download: ML11137A043 (3)


Text

1 NRR-PMDAPEm Resource From:

Mostala, Abbas A. [AAMOSTALA@energy-northwest.com]

Sent:

Thursday, May 12, 2011 2:48 PM To:

Cunanan, Arthur Cc:

Min, Seung; Mostala, Abbas A.

Subject:

RE: Request for a list of documentation to determine there are no CASS ASME III Class 1 valve less than four inches installed at Columbia Hello Arthur, The documents reviewed to determine if there are any CASS valves less than 4 inches installed at Columbia were: system flow diagrams for ASME III Class 1, valve drawings, system design specifications, purchasing requirements, and valve design specifications. This review did not identify any CASS valves less than 4 inches installed at Columbia.

The original LRA assumed that there were ASME III Class 1 CASS valves less than 4 inches because the valve design specification allowed the use of CASS valves as an alternate.

To determine the number of installed ASME III Class 1 CASS valves less than 4 inches at Columbia, the system flow diagrams were reviewed for ASME III Class 1 lines that had valves less than 4 inches. Valve drawings or purchasing requirements were reviewed for these valves to determine the material. No ASME III Class 1 CASS valves less than 4 inches were identified.

Action Request 234294 Assignment 17 will revise the valve Design Specification to only allow the future use of CASS valves as an alternate at Columbia with certain requirements associated with License Renewal, such as a new Aging Management Program per NUREG 1801 (GALL).

Thanks & Regards, Abbas Mostala,, PE License Renewal Project Manager Energy Northwest Columbia Generating Station From: Cunanan, Arthur [1]

Sent: Wednesday, May 11, 2011 9:54 AM To: Mostala, Abbas A.

Cc: Min, Seung

Subject:

Request for a list of documentation to determine there are no CASS ASME III Class 1 valve less than four inches installed at Columbia

Abbas,

2 By letter dated April 21, 2011 (GO2-11-083) (ADAM accession number: ML11115A098) the applicant stated:

DuringtheconferencecalldiscussedinReference4,EnergyNorthwestagreedtoamendtheLicenseRenewalApplication (LRA)toaddresstheexaminationsofthecastausteniticstainlesssteel(CASS)valvesincludedintheSmallBorePiping Program(ReferenceRAI3.1.2.301).However,duringthereviewofdocumentation,EnergyNorthwestdeterminedthat therearenoCASSASMEIIIclass1valveslessthanfourinchesinstalledatColumbia.Amendment31isprovidedinthe EnclosuretoremovethematerialandenvironmentcombinationfromtheLRA.

Please provide the staff a list of the documents that the applicant reviewed to determine that there are no CASS ASME III Class 1 valve less than four inches installed at Columbia.

Response via e-mail is acceptable. The response e-mail will be documented in ADAMS.

Sincerely, Arthur Cunanan Project Manager Division of License Renewal U.S. Nuclear Regulatory Commission 301-415-3897 arthur.cunanan@nrc.gov

Hearing Identifier:

NRR_PMDA Email Number:

30 Mail Envelope Properties (11F5592341C9044B8FD83A755C2DA9F70602229C)

Subject:

RE: Request for a list of documentation to determine there are no CASS ASME III Class 1 valve less than four inches installed at Columbia Sent Date:

5/12/2011 2:47:45 PM Received Date:

5/12/2011 2:48:03 PM From:

Mostala, Abbas A.

Created By:

AAMOSTALA@energy-northwest.com Recipients:

"Min, Seung" <Seung.Min@nrc.gov>

Tracking Status: None "Mostala, Abbas A." <AAMOSTALA@energy-northwest.com>

Tracking Status: None "Cunanan, Arthur" <Arthur.Cunanan@nrc.gov>

Tracking Status: None Post Office:

SERVER153.domain1.energy-northwest.com Files Size Date & Time MESSAGE 2814 5/12/2011 2:48:03 PM Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received: