MONTHYEARML1102501472011-01-24024 January 2011 Submittal of Relief Request 14R-52 Concerning Nozzle-to-Vessel Weld and Inner Examinations (Use of Code Case N-702) Project stage: Request ML1102501322011-01-24024 January 2011 Proposed Relief Request with the Requirements of 10 CFR 50.55a Concerning Reactor Pressure Vessel Circumferential Shell Welds Project stage: Request ML1105904722011-02-28028 February 2011 Relief Request l4R-52 Concerning Nozzle-to-Vessel Weld and Inner Radll Examinations Project stage: Approval ML1105900632011-02-28028 February 2011 Supplemental Information Needed for Acceptance of Requested Licensing Action Relief Request l4R-51 Project stage: Acceptance Review ML1107001462011-03-10010 March 2011 Additional Information Associated with the Acceptance Review of Relief Request Concerning Reactor Pressure Vessel Circumferential Shell Welds Project stage: Request ML1107306022011-03-18018 March 2011 Acceptance for Review of Relief Request I4R-51 Project stage: Acceptance Review ML1111203972011-04-22022 April 2011 Draft Request for Additional Information Regarding Relief Request l4R-52 Concerning Nozzle-to-Vessel Weld and Inner Radii Examinations Peach Bottom Atomic Power Station, Units 2 and 3 Project stage: Draft RAI ML1111204262011-04-22022 April 2011 Draft Request for Additional Information Regarding Relief Request l4R-51 Concerning Alternatives to Reactor Vessel Weld Examinations Project stage: Draft RAI ML1111203172011-04-22022 April 2011 Draft RAIs for PBAPS RR-I4R-51 Project stage: Draft RAI ML1111203212011-04-22022 April 2011 Draft RAIs for Pbaps RR-I4R-52 Project stage: Draft RAI ML1113901522011-05-23023 May 2011 Request for Additional Information Regarding Relief Request I4R-52 Concerning Alternatives to Reactor Vessel Weld Examinations Project stage: RAI ML1115302442011-06-0202 June 2011 Response to Request for Additional Information - Relief Request 14R-52 Concerning Nozzle-to-Vessel Weld and Inner Radii Examinations (Use of Code Case N-702) Project stage: Response to RAI ML1115202062011-06-0202 June 2011 Notice of Forthcoming Meeting with Exelon Nuclear Regarding Proposed Extended Power Uprate License Amendment Request for Peach Bottom Atomic Power Station, Units 2 and 3 Project stage: Meeting ML1127702172012-01-24024 January 2012 Requests for Relief l4R-51 and l4R-52 Project stage: Other 2011-03-18
[Table View] |
Text
Draft DRAFT REQUEST FOR ADDITIONAL INFORMATION REGARDNG RELIEF REQUEST I4R-52 CONCERNING NOZZLE-TO-VESSEL WELD AND INNER RADII EXAMINATIONS PEACH BOTTOM ATOMIC POWER STATION, UNITS 2 AND 3 DOCKET NOS. 50-277 AND 50-278 By letter to the Nuclear Regulatory Commission (NRC) dated January 24, 2011 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML110250147), Exelon Generation Company, LLC, (Exelon) submitted Relief Request I4R-52 for Peach Bottom Atomic Power Station (PBAPS), Units 2 and 3. The relief request would provide relief from the American Society of Mechanical Engineers Boiler and Pressure Vessel Code,Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components. The relief request proposes an alternative to the requirements contained in Table IWB-2500-1 concerning nozzle-to-vessel weld and nozzle inner radii examinations. The NRC staff has reviewed Exelons submittal and determined that additional information, as described below, is needed to complete the review.
to Relief Request I4R-52 lists inspection results for the nozzles for which an alternative is being requested. The NRC staff notes that all the inspection results listed are from the 3rd or 4th inspection interval.
RAI-01
Clarify whether all the inspection results for the life of each unit are included or only those conducted in accordance with Appendix VIII to the ASME Code,Section XI, Performance Demonstration for Ultrasonic Examination Systems.
RAI-02
Indicate which examinations listed in Enclosure 3 were conducted in accordance with Appendix VIII to the ASME Code,Section XI, Performance Demonstration for Ultrasonic Examination Systems.