ML110871340

From kanterella
Jump to navigation Jump to search

Request for Additional Information Regarding Relief Request PR-9
ML110871340
Person / Time
Site: Saint Lucie  
(DPR-067, NPF-016)
Issue date: 03/30/2011
From: Orf T
Plant Licensing Branch II
To: Nazar M
Florida Power & Light Co
Orf, T J, NRR/DORL/301-415-2788
References
TAC ME5190, TAC ME5191
Download: ML110871340 (3)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 March 30, 2011 Mr. Mano Nazar Executive Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420

SUBJECT:

ST. LUCIE PLANT, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING RELIEF REQUEST PR-9 (TAC NOS. ME5190 AND ME5191)

Dear Mr. Nazar:

By letter dated September 14, 2010, Florida Power & Light Company submitted Relief Request PR-9 for St. Lucie Unit Nos. 1 and 2. The relief request proposes an alternative to biennial Comprehensive Pump Testing of Group A pumps.

The NRC staff is reviewing your submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). It is requested that your RAI response be provided within 30 days of the date of this letter.

Sincerely, Tracy J. Orf, Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-335 and 50-389

Enclosure:

Request for Additional Information cc w/enclosure: Distribution via Listserv

REQUEST FOR ADDITIONAL INFORMATION (RAn REGARDING LICENSE AMENDMENT REQUEST FOR RELIEF REQUEST PR-9 ST. LUCIE PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-335 AND 50-389

Reference:

Letter from Eric S. Katzman of Florida Power &Light Company to NRC, "Fourth Ten-Year Interval Relief Request PR-9," dated September 14.2010.

RAI CPTB-1:

Please confirm that when using the proposed modified Group A test, vibration tests will be performed, and the acceptance criteria for the vibration tests will be the same as for Group A tests shown in Table IST8-5200-1.

ENCLOSURE

March 30, 2011 Mr. Mano Nazar Executive Vice President, Nuclear and Chief Nuclear Officer Florida Power and Light Company P.O. Box 14000 Juno Beach, Florida 33408-0420 SUBJECT ST. LUCIE PLANT, UNITS 1 AND 2 - REQUEST FOR ADDITIONAL INFORMATION REGARDING RELIEF REQUEST PR-9 (TAC NOS. ME5190 AND ME5191)

Dear Mr. Nazar:

By letter dated September 14, 2010, Florida Power & Light Company submitted Relief Request PR-9 for St. Lucie Unit Nos. 1 and 2. The relief request proposes an alternative to biennial Comprehensive Pump Testing of Group A pumps.

The NRC staff is reviewing your submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). It is requested that your RAI response be provided within 30 days of the date of this letter.

Sincerely, IRA!

Tracy J. Ort, Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-335 and 50-389

Enclosure:

Request for Additional Information cc w/enclosure: Distribution via Listserv DISTRIBUTION:

PUBLIC RidsNrrLABClayton RidsRgn2MailCenter LPL2-2 r/f RidsNrrDciCptb RWolfgang. NRR RidsN rrDorlLpl2-2 RidsAcrsAcnw_MailCTR RidsN rrPMStLucie RidsOgcRp ADAMS A N

ML110871340 ccesslon 0.:

  • Bsymemo OFFICE LPLlI*2/PM LPLlI-21LA CPTB/BC*

LPLII-21BC LPLlI-21PM NAME TOrf BClayton AMcMurtray DBroaddus TOrf DATE 03/29/11 03/28/11 03/15/11 03/29/11 03/30/11 OFFICIAL AGENCY RECORD