Audit of Salems use of WESTEMS Fatigue Software On Yee March 11, 2011

Identified Issues in New Reactors

- Two issues associated with WESTEMS performing NB-3600 calculations:

  • the use of the algebraic summation of three orthogonal vectors
  • methodology for stress combination related to thermal tstresses

- Configuration control in WESTEMS - the ability of users to modify intermediate data (peak and valley stresses/times) used in the analyses 2

Impact to License Renewal

  • Salem Nuclear Generating Station

- RAI 4.3-07 issued November 22, 2010

  • Requested applicant to perform benchmark calculations for two locations (pressurizer surge nozzle and 1.5 BIT safety injection nozzle)
  • Discuss applicability of identified issues 3

Impact to License Renewal

  • Audit Objectives

- Review benchmark calculations to ensure WESTEMS provides results comparable to traditional NB-3200 analysis Address the acceptability of analyst intervention in

- Address the acceptability of analyst intervention in modifying intermediate WESTEMS data

- Address the role of the WESTEMS NB-3600 module in license renewal calculations 4

Audit Observations

  • January 18-19, 2011

- Documentation of analyst intervention was not available

- Applicant verbally justified analyst intervention for the BIT nozzle

- Confirmed that WESTEMS calculations that support the Salem LRA did not use the NB-3600 module C

fi d th t WESTEMS id lt th t bl d

- Confirmed that WESTEMS provides results that are reasonable and consistent with a traditional ASME Code Section III, NB-3200 analysis for the two locations

- Applicant agreed to revise calculations to document results, for both locations, with and without analyst intervention

  • February 8, 2011

- Revised calculations for both locations documented the results with and without analyst intervention

- Justifications for analyst intervention needs to be sufficiently specific 5

Results from Audit Use of a software package to perform fatigue calculations should be consistent with ASME Code,Section III Analyst intervention should be justified and documented when using a software package to perform fatigue calculations WESTEMS NB-3600 module should not be used until identified issues are resolved issues are resolved The staff has reasonable assurance that Salems use of the WESTEMS NB-3200 Design CUF module provides results that are consistent with a traditional ASME Code,Section III NB-3200 analysis Options are currently being considered on how to generically communicate the concerns and results of the audit 6