CONSTRAINT ON RELEASES OF

AIRBORNE RADIOACTIVE MATERIALS TO THE ENVIRONMENT

FOR LICENSEES OTHER THAN POWER REACTORS

A. INTRODUCTION

In 10 CFR Part 20, "Standards for Protection Against Radiation," § 20.1302(b) requires that:

A licensee shall show compliance with the annual dose limit in § 20.1301 by (1) Demonstrating by measurement or calculation that the total effective dose equivalent to the individual likely to receive the highest dose from the licensed operation does not exceed the annual dose limit; or (2) Demonstrat ing that (i) The annual average concentrations of ra dioactive material released in gaseous and liquid effluents at the boundary of the unrestricted area do not exceed the values specified in Table 2 of Appen dix B to Part 20; and (ii) If an individual were contin uously present in an unrestricted area, the dose from external sources would not exceed 0.002 rem

(0.02 mSv) in an hour and 0.05 rem (0.5 mSv) in a year.

In addition, 10 CFR 20.1101(d) requires that:

To implement the ALARA [as low as is reasonably achievable] requirements of § 20.1101(b), and not withstanding the requirements in § 20.1301 of this part, a constraint on air emissions of radioactive ma terial to the environment, excluding radon-222 and its daughters, shall be established by licensees other USNRC REGULATORY GUIDES

Regulatory Guides are issued to describe and make available to the public such informa tion as methods acceptable to the NRC staff for implementing specific pals of the Com mission's regulations, techniques used by the staff in evaluating specific problems or pos tulated accidents, and data needed by the NRC staff in its review of applications for per mits and licenses Regulatory guides are not substitutes for regulations, and compliance with them is not required. Methods and solutions different from Itho sat out in the guides will be acceptable if they provide a basis for the findings requisite to the issuance or con tinuance of a permit or license by the Commission.

This guide was issued after consideration of comments received from the public. Com ments and suggestions for improvements in these guides are encouraged at all times, and guides will be revised, as approprate, to accommodate comments and to reflect new in formation or experience.

Written comments may be submitted to the Rules Review and Directives Branch, DFIPS.

ADM, U S Nuclear Regulatory Commission, Washington, DC 20555-0001.

than those subject to 10 CFR 50.34a, such that the individual member of the public likely to receive the highest dose will not be expected to receive a total effective dose equivalent in excess of 10 mrem (0.1 mSv) per year from these emissions. If a licensee subject to this requirement exceeds this dose con straint, the licensee shall report the exceedance as provided in 10 CFR 20.2203 and promptly take ap propriate corrective action to ensure against recurrence.

This regulatory guide provides guidance on meth ods acceptable to the NRC staff for compliance with the constraint on air emissions to the environment. If addi tional significant comments are received in the first year following its issuance, the staff will revise the guide as ap propriate. Guidance on ALARA programs can be found in other regulatory guides. Although these guides deal primarily with occupational exposure and may be specif ic to one type of licensee, they contain programmatic in formation that may be useful to all licensees. These guides are:

0

Regulatory Guide 8.10, "Operating Philosophy for Maintaining Occupational Radiation Exposures As Low As Is Reasonably Achievable." This guide de lineates the components of an ALARA program.

The guides are issued in the following ten broad divisions:

1. Power Reactors

2. Research and Test Reactors

3. Fuels and Matenels Facilities

4. Environental and Siting

5. Materials and Plant Protection

& Products

7. Transportation S

Occupational Health

9g Antitrust and Financial Review

10

General Single copies of regulatory guides may be obtained free of charge by writing the Office of Adminstration, Attention: Distribution and Services Section, U.S. Nuclear

leguloy Commission. Washington, DC 20655-0001; or by ftax at (301)415-2280

Issued guides may also be purchased from the National Technical Information Service onr a standing order basis. Details on this service may be obtained by writing NTIS. 5285 Port Royal Road, Springfield, VA 22161.

"* Regulatory Guide 8.18, "Information Relevant to Ensuring that Occupational Radiation Exposures at Medical institutions Will Be As Low As Reasonably Achievable."

"

Regulatory Guide 8.31, "Information Relevant to Ensuring that Occupational Radiation Exposures at Uranium Mills Will Be As Low As Is Reasonably Achievable."

"* Regulatory Guide 8.37, "ALARA Levels for Efflu ents from Materials Facilities."

0

Regulatory Guide 10.8, "Guide for the Preparation of Applications for Medical Use Programs." Sec tion 1.3 and Appendix G deal specifically with ALARA programs for medical facilities.

In addition, further information can be found in Re vision 1 to NUREG-0267, "Principles and Practices for Keeping Occupational Radiation Exposures As Low As Reasonably Achievable" (October 1982).1 The information collections contained in this regu latory guide are covered by the requirements of 10 CFR

Part 20, which were approved by the Office of Manage ment and Budget, approval number 3150-0014. The NRC may not conduct or sponsor, and a person is not re quired to respond to, a collection of information unless it displays a currently valid OMB control number.

B. DISCUSSION

The dose limits in 10 CFR Part 20 are based on limit ing dose to an acceptably low level of risk to the exposed individual. However, any radiation exposure may carry some risk. Thus, the NRC requires licensees to take ac tions, to the extent practicable, utilizing procedures and engineering controls to further reduce risk below the lev els implicit in the dose limits in keeping with the princi ple that exposures should be as low as is reasonably achievable. This is the goal and purpose for radiation protection programs. In order to achieve this goal, li censees must control the way radioactive material is han dled from receipt through disposal.

ALARA

Components of an effective radiation protection program, as required by 10 CFR 20.1101, include radi ation exposure control, written procedures and policies, control of radioactive materials, radioactive contamina tion control, radioactive waste management, training, program reviews, and audits.

'Copies are available for purchase from the U.S. Government Printing Office, PO. Box 37082, Washington, DC 20013-7082, telephone

(202) 512-2249; or from the National Technical Information Service by writing NTIS at 5285 Port Royal Road, Springfield, VA 22161. Co pies are available for inspection or copying for a fee from the NRC Pub lic Document Room at 2120 L Street NW., Washington, DC; the PDR's mailingaddress is Mail StopLL-6, Washington, DC20555; telephone

(202)634-3273; fax (202)634-3343.

The NRC staff examines licensee programs to deter mine whether they are in compliance with the require ments of 10 CFR Part 20. This guide addresses only a part of a licensee's overall radiation protection program.

Specifically, it addresses methods for demonstrating compliance with the constraint on releases of airborne radioactive materials to the environment. In addition to controlling doses from the releases of airborne radioac tive materials to the environment, licensees must imple ment a radiation protection program that controls liquid effluents and dose rates in unrestricted areas.

Many NRC licensees possess source, byproduct, or special nuclear material in a form that would not cause doses to members of the public from releases of airborne radioactive material to the environment. These licens ees include radiographers, well loggers, and other users of sealed sources. These licensees need not take any ac tions to demonstrate compliance with the constraint on releases of airborne radioactive materials to the environment.

CONSTRAINTS

A dose limit derived from a basic radiation protec tion standard is the upper acceptable bound of radiation dose and is needed to protect the health and safety of in dividuals; a limit is a value not to be exceeded. Such lim its should be set with the assumption that effluent re leases associated with licensed activities would result in doses to the public that are substantially below that val ue. Such limits are approached only under unusual cir cumstances, and only for a small fraction of the exposed population. A constraint is a dose value above which li censees are required to report to NRC and to take cor rective actions to lower the dose below the constraint val ue. Enforcement action would only occur if a licensee fails to report an exceedance of the constraint or fails to take appropriate and timely corrective actions.

C. REGULATORY POSITION

1. CONSTRAINT ON ENVIRONMENTAL AIR

EMISSIONS

The following methods are acceptable to the NRC

staff for determining the dose to members of the public from exposure to airborne radioactive material that has been released to the environment by NRC licensees oth er than power reactors. Licensees should choose a moni toring period (e.g., a year, month, or quarter) to demon strate compliance with the airborne emissions constraint in accordance with 10 CFR 20.1101(d). For most licens ees, the monitoring period will be one year.

1.1 Licensees who (1) operate a nuclear power reac tor subject to 10 CFR 50.34a or (2) possess and use radio nuclides only in the form of sealed sources need not take any actions to demonstrate compliance with the constraint.

4.20-2

1.2 Radioactive materials in sealed containers that remain unopened and have not leaked during the assess ment period need not be included in the calculations. Ex amples of sealed containers would include radiopharma ceuticals in unopened manufacturers packages and materials in undamaged shipping containers. Indepen dent spent fuel storage canisters that do not have vents to the atmosphere may also be considered sealed containers.

1.3 Effluents from patients need not be included if compliance with the constraint is demonstrated by using an inventory approach. If compliance with the constraint is demonstrated by using measured or calculated con centrations of radioactive materials in the environment, the contribution from patients is considered insignifi cant and need not be considered.

1.4 If it can be determined that some detected mate rials did not result from licensed activities of the licens ee, only radioactive materials from the licensed activity need be considered. Materials that are windblown from other facilities need not be considered.

1.5 In determining the member of the public likely to receive the highest dose from airborne radioactive material released from licensed operations to the envi ronment, licensees need not consider nonresidents with in the facility boundary.

2.

CALCULATION OF DOSE TO THE MEMBER

OF THE PUBLIC LIKELY TO RECEIVE THE

HIGHEST DOSE FROM AIR EFFLUENTS

In demonstrating compliance with

10

CFR

20.1101(d), licensees should determine whether there have been any facility or design modifications, increases in radionuclide inventories, or operational changes; li censees should determine whether any of these factors resulted in variations to airborne emissions since the last monitoring period. If licensee operations have not changed, the review of licensed operations and demon stration of compliance with the constraint will be rela tively straightforward.

Any of the following methods are acceptable for demonstrating compliance with 10 CFR 20.1101(d).

2.1 The simplest screening technique is to assume that the air concentration at the receptor is equal to the air concentration measured at the point of release. This is analogous to using Appendix B to 10 CFR Part 20 to demonstrate compliance with the dose limits in Part 20.

2.2 To demonstrate compliance with the constraint on air emissions, the licensee should demonstrate, by measurement or calculation, that the annual average concentration of airborne radioactive material released to the environment does not exceed 20% of the values in Column 1 of Table 2 in Appendix B to 10 CFR Part 20.

The following formula demonstrates this technique.

C

N

V

Where:

C

=

Average air concentration at the receptor (Ci/m 3 or IiCi/ml)

f

=

Fraction of the time the wind blows toward the receptor of interest (dimensionless)

(For a single "puff" release, the appropri ate value is 1.)

Q

=

Effluent release rate (Ci/s)

V

=

Volumetric flow rate at the point of release (m3/s)

The "sum of the fractions" technique should be used to assess compliance for effluents containing multiple ra dionuclides. With this technique, if radionuclides "a,"

"b," and "c" are present in concentrations Ca, Cb, and Cc, and if the applicable effluent concentrations in Column 1 of Table 2 in Appendix B to 10 CFR Part 20 are ECa, ECb, and ECc respectively, satisfying the following in equality is sufficient to demonstrate compliance with the constraint.

C-- +

+

< 0.2 TC-

TEC,

EC,

2.3 Additional methods acceptable to the NRC staff for demonstrating compliance with 10 CFR 20.1101(d)

can be found in the worksheets contained in either NCRP Commentary No. 3, "Screening Techniques for Determining Compliance with Environmental Stan dards,"2 or EPA 520/1-89-002, "A Guide for Deter mining Compliance with the Clean Air Act Standards for Radionuclide Emissions from NRC-Licensed and Non DOE Federal Facilities" (Revision 2).3

2.4 Another method that is acceptable to the NRC

staff for demonstrating compliance with

10 CFR

20.1101(d) is the use of the computer code COMPLY.

COMPLY was developed by the EPA to assess doses by using site-specific information in the determination of dose. COMPLY has four screening levels. In Level 1, the simplest level, only the quantity of radioactive material possessed during the monitoring period is entered. The calculations are based on generic parameters. Level 4 produces a more representative dose estimate by provid ing for more complete treatment of air dispersion by re quiring site-specific information. It is expected that all

2NCRP Commentary No. 3 was published in January 1989 and the ad dendum was published in October 1989. Copies may be purchased from the National Council on Radiation Protection and Measure ments, NCRP Publications, 7910 Woodmont Avenue, Bethesda, MD

20814.

3Copies may be obtained from the U.S. Environmental Protection Agency, Office of Radiation and Indoor Air, 401 M Street SW, Wash ington, DC 20460.

4.20-3

NRC licensees will be able to demonstrate compliance at one of the four levels. The basis for the compliance mea sures in COMPLY are contained in "Background Infor mation Document: Procedures Approved for Demon strating Compliance with 40 CFR Part 61, Subpart I"

(EPA 520/1-89-001, October 1989).4 If a computer code other than those listed above is used to demonstrate compliance with the constraint, the licensee should be prepared to demonstrate that the code has undergone verification and validation (V & V).

For more information on software quality assurance in cluding V & V, licensees may refer to NUREG/

BR-0167, "Software Quality Assurance Program and Guidelines." This document can be purchased from the U.S. Government Printing Office, PO. Box 37082, Wash ington, DC 20402-9328.

3.

REPORTS TO NRC IF CONSTRAINT HAS

BEEN EXCEEDED

If the constraint of 10 mrem (0.1 mSv) per year to the member of the public likely to receive the highest dose has been exceeded as determined by measurement or calculation, 10 CFR 20.2203(a)(2)(vi) requires licens ees to send a report to the NRC within 30 days after

4Copies of the EP

A. Background Information

Document and the COM

PLY computer code with its Users Guide may be obtained by writing to the Center for Federal Guidance and Air Standards (6602J), Office of Radiation and Indoor Air, Environmental Protection Agency, Wash ington, DC 20460. It can also be downloaded from the Technology

"li*ansfer Network (TTN) Electronic Bulletin Board under the Office of Radiation and Indoor Air technical information area. The number for the TTN is (919)541-5742. In addition, EPA has pages on the World Wide Web as another mechanism to provide computer codes to licensees.

The addresses are ttnftp.rtpnc.epa.gov and ttnwww.rtpnc.epa.gov.

learning of the dose in excess of the constraint, and 10

CFR 20.2203(b)(1) requires licensees to describe the ex tent of exposure. The report should include the follow ing information.

"* An estimate of the dose

"* The concentrations of the radioactive material released

"* The cause of the elevated concentrations in effluents

"* The corrective steps taken or planned to ensure against a recurrence

"* A schedule for completing the corrective steps. The report should contain enough information to allow the NRC staff to verify the calculations.

The report should be sent to the U.S. Nuclear Regu latory Commission, Document Control Desk, Washing ton, DC 20555-0001, with a copy to the appropriate NRC Regional Office listed in Appendix D to 10 CFR

Part 20.

D. IMPLEMENTATION

The purpose of this section is to provide informa tion to applicants and licensees regarding the NRC

staff's plans for using this guide.

Except in those cases in which an applicant proposes an acceptable alternative method for complying with specified portions of the NRC's regulations, the meth ods described in this guide will be used in the evaluation of applications for new licenses, license renewals, or li cense amendments and for evaluating compliance with

10 CFR Part 20.

4.20-4

REGULATORY ANALYSIS

A separate regulatory analysis was not prepared for this regulatory guide. The regulatory analysis prepared for the amendments to 10 CFR Part 20, "Standards for Protection Against Radiation," provides the regulatory basis for this guide. A copy of this regulatory analysis is available, as an enclosure to SECY-95-133, for inspection or copying for a fee at the NRC

Public Document Room, 2120 L Street NW, Washington, DC.

4.20-5

Federal Recycling Program

)

UNITED STATES

NUCLEAR REGULATORY COMMISSION

WASHINGTON, DC 20555-0001 I

FIRST CLASS MAIL

POSTAGE AND FEES PAID

USNRC

PERMIT NO. G-67 OFFICIAL BUSINESS

PENALTY FOR PRIVATE USE, $300

0

0

6i U.

0

w z_

C-)

z_

a.

z z

.I

z

(:

(6