ML110050433

From kanterella
Jump to navigation Jump to search
HC.IC-CC.SE-0003(Q) - Rev. 27, Nuclear Instrumentation System - Channel C Source Range Monitor C51-K600C
ML110050433
Person / Time
Site: Salem, Hope Creek  PSEG icon.png
Issue date: 12/16/2008
From:
Public Service Enterprise Group
To:
Office of Nuclear Reactor Regulation
References
LR-N10-0355 HC.IC-CC.SE-0003(Q), Rev 27
Download: ML110050433 (62)


Text

PSEG Internal Use Only PSEG NUCLEAR L.L.C.

Page 1 of 1 MAINTENANCE HC.IC-CC.SE-0003(Q) - Rev. 27 NUCLEAR INSTRUMENTATION SYSTEM - CHANNEL C SOURCE RANGE MONITOR C51-K600C USE CATEGORY : I

Biennial Review Performed: Yes ____ No ____ NA T

Packages and Affected Document Numbers incorporated into this revision: None

The following OTSCs were incorporated into this revision: None REVISION

SUMMARY

Performed the following editorial changes (70092176):

Updated to current format and content Updated cross reference due to superseding Changed CDV to PC as required.

IMPLEMENTATION REQUIREMENTS Effective Date:

12/16/2008

HC.IC-CC.SE-0003(Q)

Hope Creek Page 1 of 61 Rev. 27 NUCLEAR INSTRUMENTATION SYSTEM - CHANNEL C SOURCE RANGE MONITOR C51-K600C TABLE OF CONTENTS Section Title Page 1.0 PURPOSE........................................................ 4 2.0 PREREQUISITES................................................... 4 3.0 PRECAUTIONS AND LIMITATIONS.................................... 4 4.0 EQUIPMENT/MATERIAL REQUIRED................................... 5 5.0 PROCEDURE...................................................... 6 5.1 Test Setup................................................. 6 5.2 Downscale Test............................................ 10 5.3 Upscale Alarm Test......................................... 11 5.4 Upscale Trip Test........................................... 12 5.5 Detector Not Full In/Retract Permit Test.......................... 13 5.6 Period Trip Test............................................ 15 5.7 Inoperative Trip Test

........................................ 16 5.8 Pre-Regulator (VR27) Test.................................... 18 5.9 Voltage Regulator (VR29) Test

................................ 18 5.10 Internal 10 and 105 Circuit Test................................ 18 5.11 Ramp Circuit Test........................................... 19 5.12 LCR Front Panel Meter, Remote LCR Recorder and Computer Point B3029 Test................................................ 19 5.13 LCR Amplifier (AR23) Zero and Period Amplifier (AR14) Zero Test..... 20 5.14 Period Circuit Test.......................................... 20 5.15 Period Front Panel Meter and Computer Point B3003 Test........... 20 5.16 High Voltage and Inoperative Test.............................. 21 5.17 Data Evaluation............................................ 22 5.18 Calibration Setup........................................... 22 5.19 Pre-Regulator (VR27) Calibration............................... 22 5.20 Voltage Regulator (VR29) Calibration........................... 23 5.21 LCR Amplifier (AR23) Zero Calibration

.......................... 23 5.22 Period Amplifier (AR14) Zero Calibration......................... 24 5.23 Internal 10 and 105 Circuit Calibration........................... 24 5.24 Ramp Circuit Calibration...................................... 25

HC.IC-CC.SE-0003(Q)

Hope Creek Page 2 of 61 Rev. 27 TABLE OF CONTENTS Section Title Page 5.25 Period Circuit Calibration..................................... 26 5.26 Downscale Alarm Calibration.................................. 27 5.27 Upscale Alarm Calibration.................................... 27 5.28 Upscale Trip Calibration...................................... 28 5.29 Retract Permit Downscale Calibration........................... 28 5.30 Period Trip Calibration....................................... 29 5.31 LCR Front Panel Meter M1 Calibration

.......................... 30 5.32 Remote LCR Recorder Calibration.............................. 30 5.33 Computer Point B3029 Calibration.............................. 31 5.34 Period Front Panel Meter M2 Calibration......................... 31 5.35 Computer Point B3003 Calibration.............................. 32 5.36 Low High Voltage Inoperative Trip Calibration..................... 33 5.37 Data Verification Setup....................................... 34 5.38 Pre-Regulator (VR27) Verification.............................. 34 5.39 Voltage Regulator (VR29) Verification........................... 34 5.40 LCR Amplifier (AR23) Zero Verification.......................... 35 5.41 Period Amplifier (AR14) Zero Verification......................... 35 5.42 Internal 10 and 105 Circuit Verification........................... 35 5.43 Ramp Circuit Verification..................................... 36 5.44 Period Circuit Verification..................................... 37 5.45 Downscale Alarm Verification.................................. 37 5.46 Upscale Alarm Verification.................................... 38 5.47 Upscale Trip Verification...................................... 38 5.48 Retract Permit Downscale Verification........................... 39 5.49 Period Trip Verification....................................... 39 5.50 Low High Voltage Inoperative Circuit Verification................... 40 5.51 Remote LCR Recorder Verification............................. 41 5.52 LCR Front Panel Meter M1 and Computer Point B3029 Verification.... 41 5.53 Period Front Panel Meter M2 and Computer Point B3003 Verification.. 42 5.54 Return to Service........................................... 43 6.0 RECORDS....................................................... 45

7.0 REFERENCES

.................................................... 45

HC.IC-CC.SE-0003(Q)

Hope Creek Page 3 of 61 Rev. 27 TABLE OF CONTENTS Section Title Page 8.0 REFERENCE DRAWINGS........................................... 47 8.1 VOLTAGE REGULATOR..................................... 47 8.2 LCR Amplifier.............................................. 48 8.3 SIGNAL GENERATOR MODULE.............................. 49 8.4 PERIOD GENERATOR MODULE.............................. 50 ATTACHMENTS, Data Package.................................................. 51, Administrative Data Sheet......................................... 59 Exhibit 1, Operations Information Sheet.......................................... 60

HC.IC-CC.SE-0003(Q)

Hope Creek Page 4 of 61 Rev. 27 1.0 PURPOSE

To give instructions for test and calibration of Source Range Monitor (SRM) Channel C, C51-K600C. This procedure will verify calibration and operability of the following equipment:

H1SE -1SEXAM-AR14C-C51 H1SE -1SEXSL-Z16SRCC51 H1SE -1SEXAM-AR23C-C51 H1SE -1SEXSHL-Z17SRCC51 H1SE -1SEXI-M1SRMCC51 H1SE -1SEXS-Z18SRCC51 H1SE -1SEXI-M2SRMCC51 H1SE -1SEVR-27SRMCC51 H1SE -1SEXPS-21C-C51 H1SE -1SEVR-29SRMCC51 H1SE -1SEXR-R602A-C51 (Blue Pen)

When successfully performed in conjunction with Channel Calibration HC.IC-CC.SE-0041(Q), this procedure will satisfy part of surveillance requirements of Technical Specification 4.3.6-1.3.a through 4.3.6-1.3.d and 4.3.7.6.a.2.

When performed in Operational Conditions 2, 3, 4 or 5, this procedure includes Functional Test of SRM Channel C and credit may be taken for its performance with successful completion of this procedure.

When performed in Operational Condition 1, this procedure does NOT include the Functional Test of SRM Channel C. The Functional Test must also be completed in order to satisfy the Channel Calibration requirements.

2.0 PREREQUISITES

___ 2.1 RECORD M&TE data on Attachment 2.

___ 2.2 REQUEST SM/CRS permission to perform this test.

___ 2.3 REQUEST SM/CRS to determine if present plant operating condition (mode) requires RPS scram (non-coincident) shorting links to be removed for core alterations.

___ 2.4 SIGN Exhibit 1 AND FORWARD to RO.

3.0 PRECAUTIONS AND LIMITATIONS

___ 3.1 ENSURE all applicable generic precautions and limitations of MA-AA-716-009, Use of Maintenance Procedures, are applied during performance of this procedure.

___ 3.2 Performance of this procedure will initiate a Rod Block.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 5 of 61 Rev. 27 4.0 EQUIPMENT/MATERIAL REQUIRED NOTE The following equipment or its equivalent (i.e., with equal or better accuracy and adequate range to measure the desired parameter) will be required for performance of this procedure.

4.1 M&TE

DMM (Keithley 197/1978).

DMM (Fluke 45 for ripple voltage)

Electronic Counter (HP Model 5328A).

Stopwatch (Total Timer 700).

4.2 Additional Tools and Equipment

Extender Cards GE 129B2048G1 - 2 required.

GE 129B2048G2 - 1 required.

GE 129B2048G7 - 1 required.

Jumper, No. 14 AWG stranded, approximately 12 inches, banana plugs on each end - 3 required.

INOP INHIBIT switch clamp.

SRM Test Relay (Mode 1 Testing)

HC.IC-CC.SE-0003(Q)

Hope Creek Page 6 of 61 Rev. 27 5.0 PROCEDURE 5.1 Test Setup 5.1.1.

VERIFY Prerequisites have been met.

5.1.2.

VERIFY Precautions and Limitations have been reviewed.

5.1.3.

VERIFY a total of 2 SRM channels (3 if this test is being performed in OPERATIONAL CONDITION 2) are available by performing the following for each channel:

VERIFY drawer mode switch for each SRM drawer is in OPERATE

VERIFY INOP status light, off (each SRM drawer)

VERIFY SOURCE RANGE NEUTRON MONITORING - MONITOR STATUS, UPSC AL OR INOP status light, off for each SRM channel (MCP) (N/A if in OPERATIONAL CONDITION 1).

VERIFY RO regards each SRM channel OPERABLE (N/A if in OPERATIONAL CONDITION 1).

5.1.4.

VERIFY the following:

RPS MODE SWITCH not in SHUTDOWN (MCP)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, off (N/A if RPS MODE SWITCH is in RUN).

5.1.5.

IF SM/CRS has determined it necessary for non-coincident shorting links to be removed for core alterations, VERIFY non-coincident scram shorting links are installed between the following terminals:

Z-8 and Z-9 (panel 10C609)

A-8 and A-9 (panel 10C609)

Z-8 and Z-9 (panel 10C611)

A-8 and A-9 (panel 10C611) 5.1.6.

NOTIFY SM/CRS that removal of non-coincident shorting links during performance of this test may cause a RPS trip (full scram).

HC.IC-CC.SE-0003(Q)

Hope Creek Page 7 of 61 Rev. 27 5.1.7.

REQUEST Job Supervisor to perform the following:

A.

OBTAIN current HV and HV INOP settings from NOTES section of ICD card for H1SE -1SESC-K600C-C51.

B.

RECORD OPER. HV (HV Setting), INOP TRIP (HV INOP) and W.O.#

in DESIRED columns of Attachment 1, Section 18.0.

5.1.8.

DETERMINE high voltage DESIRED RANGE and CALIBRATION TOLERANCE as follows:

A.

MULTIPLY DESIRED OPER. HV on Section 18.0 by 0.02 to obtain high voltage tolerance.

B.

SUBTRACT value in Step 5.1.8.A from DESIRED OPER. HV AND RECORD value in DESIRED RANGE FROM and CALIBRATION TOLERANCE FROM columns for OPER. HV on Attachment 1, Section 18.0.

C.

ADD value in Step 5.1.8.A to DESIRED OPER. HV AND RECORD value in DESIRED RANGE TO and CALIBRATION TOLERANCE TO columns for OPER. HV on Attachment 1, Section 18.0.

5.1.9.

DETERMINE low high voltage inoperative trip DESIRED RANGE and CALIBRATION TOLERANCE as follows:

A.

MULTIPLY DESIRED INOP TRIP on Attachment 1, Section 18.0 by 0.02 to obtain low high voltage inoperative trip tolerance.

B.

SUBTRACT value in Step 5.1.9.A from DESIRED INOP TRIP AND RECORD value in DESIRED RANGE FROM and CALIBRATION TOLERANCE FROM columns for INOP TRIP on Attachment 1, Section 18.0.

C.

ADD value in Step 5.1.9.A to DESIRED INOP TRIP AND RECORD value in DESIRED RANGE TO and CALIBRATION TOLERANCE TO columns for INOP TRIP on Attachment 1, Section 18.0.

5.1.10.

RECORD meter reading from Log Count Rate (LCR) meter at SRM C drawer. (panel 10C636)

(cps) 5.1.11.

REQUEST RO to bypass SRM channel C.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 8 of 61 Rev. 27 5.1.12.

LOCATE, LABEL AND REMOVE Pre-Regulator module (VR27) from PC SRM C drawer.

5.1.13.

IF RPS MODE SWITCH on MCP is in RUN, PREPARE SRM for OPERATIONAL CONDITION 1 testing by performing the following:

A.

LOCATE, LABEL AND REMOVE RUN relay K17 from TRIP AUX PC UNIT C. (SRM C, panel 10C636).

B.

INSTALL SRM Test Relay in K17 socket.

5.1.14.

PLACE Pre-Regulator module on 129B2048G1 plug-in adapter AND INSTALL adapter and Pre-regulator in SRM drawer.

5.1.15.

JUMPER out SRM contributions to Activity Control (Card) No. 1 rod block inputs as follows:

A.

INSTALL a jumper between test point terminals TB4-7 (TRIP AUX CV UNIT A) and CC-89. (front of panel 10C635) 5.1.16.

JUMPER out IRM contributions to Activity Control (Card) No. 1 rod block inputs as follows:

A.

INSTALL jumper between test point terminals TB4-10 (TRIP AUX CV UNIT A) and BB-96. (front of panel 10C635) 5.1.17.

REQUEST RO to perform the following:

A.

VERIFY SRM C detector is in full-out position.

B.

DRIVE SRM C detector in for 5 seconds.

C.

VERIFY SRM C detector is not in full-out position.

5.1.18.

SIMULATE SRM C detector full-in by performing the following:

A.

INSTALL a jumper between test point terminals AA-40 and AA-46 at CV panel H21-P008. (Reactor Building area 13, elevation 102',

room 4317) 5.1.19.

REQUEST RO to place IRM RANGE SELECT, CHANNEL A, Range Switch in Range 2.

5.1.20.

IF not done, REQUEST RO to remove IRM channel A from bypass.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 9 of 61 Rev. 27 5.1.21.

VERIFY the following:

MONITOR STATUS, SRM C BYPASS status lamp, on (SOURCE RANGE NEUTRON MONITORING section of MCP)

BYPASSED SRM CH C status lamp, on (TRIP AUX UNIT C, panel 10C636)

Computer point C039, SRM BYPASS, in alarm 5.1.22.

CONNECT DMM between AR23-J1 (+) and VR29-J2 (-) at SRM C.

(panel 10C636) 5.1.23.

PLACE SRM C (mode) selector switch S1 to TRIP TEST (LCR).

5.1.24.

ADJUST Trip Test potentiometer R10 in SRM C for an indication of 10 CPS on LCR front panel meter.

5.1.25.

RESET SRM C by momentarily placing RESET switch on SRM front panel to TRIP.

NOTE INOP INHIBIT switch is cycled to preclude switch failure due to oxidation of contacts. A clamp installed on INOP INHIBIT switch will be used to PRESS/RELEASE switch throughout testing.

INOP INHIBIT switch S4 must be held pressed from Step 5.1.29 through Step 5.6.9.

5.1.26.

CYCLE INOP INHIBIT switch five times.

5.1.27.

INSTALL a clamp on SRM C INOP INHIBIT switch S4.

5.1.28.

Using clamp, PRESS AND MAINTAIN SRM C INOP INHIBIT switch S4 pressed.

5.1.29.

REQUEST RO to remove SRM channel C from bypass.

5.1.30.

VERIFY INOP status lamp on SRM C front panel, off.

5.1.31.

VERIFY Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, off (N/A if RPS MODE SWITCH in RUN).

5.1.32.

VERIFY LED, off (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN).

HC.IC-CC.SE-0003(Q)

Hope Creek Page 10 of 61 Rev. 27 5.2 Downscale Test 5.2.1.

Slowly ADJUST Trip Test potentiometer R10 CCW until DOWNSCALE status lamp, on (SRM front panel).

5.2.2.

RECORD DMM indication in AS FOUND TRIP column of Attachment 1, Section 1.0.

5.2.3.

VERIFY the following:

Control Room annunciator C3 E1, SRM DOWNSCALE, on (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, on (N/A if RPS MODE SWITCH in RUN)

LED, on (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

Computer point C013, ROD BLOCK - REFUEL MODE, in alarm (N/A if RPS MODE SWITCH not in REFUEL)

Computer point C048, ROD OUT BLOCK, in alarm (N/A if RPS MODE SWITCH in RUN)

MONITOR STATUS, SRM C DNSC status lamp, on (SOURCE RANGE NEUTRON MONITORING section of MCP) 5.2.4.

Slowly ADJUST R10 CW until DOWNSCALE status lamp, off (SRM front panel).

5.2.5.

RECORD DMM indication in AS FOUND RESET column of Attachment 1, Section 1.0.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 11 of 61 Rev. 27 5.2.6.

VERIFY the following:

Control Room annunciator C3 E1, SRM DOWNSCALE, off (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, off (N/A if RPS MODE SWITCH in RUN)

LED, off (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

Computer point C013, ROD BLOCK - REFUEL MODE, not in alarm (N/A if RPS MODE SWITCH not in REFUEL)

Computer point C048, ROD OUT BLOCK, not in alarm (N/A if RPS MODE SWITCH in RUN)

MONITOR STATUS, SRM C DNSC status lamp, off (SOURCE RANGE NEUTRON MONITORING section of MCP) 5.3 Upscale Alarm Test 5.3.1.

Slowly ADJUST R10 CW until UPSCALE ALARM status lamp, on (SRM front panel).

5.3.2.

RECORD DMM indication in AS FOUND TRIP column of Attachment 1, Section 2.0.

5.3.3.

VERIFY the following:

Control Room annunciator C3 C1, SRM UPSCALE OR INOPERATIVE, on (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, on (N/A if RPS MODE SWITCH in RUN)

LED, on (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

Computer point C015, SRM UPSC ALARM, in alarm

MONITOR STATUS, SRM C UPSC AL OR INOP status lamp, on (SOURCE RANGE NEUTRON MONITORING section of MCP)

HC.IC-CC.SE-0003(Q)

Hope Creek Page 12 of 61 Rev. 27 5.4 Upscale Trip Test 5.4.1.

Slowly ADJUST R10 CW until UPSCALE TRIP status lamp, on (SRM front panel).

5.4.2.

RECORD DMM indication in AS FOUND TRIP column of Attachment 1, Section 3.0.

5.4.3.

VERIFY MONITOR STATUS, SRM C UPSC TRIP status lamp, on (SOURCE RANGE NEUTRON MONITORING section of MCP).

5.4.4.

While holding RESET switch on SRM front panel in TRIP, slowly ADJUST R10 CCW until UPSCALE TRIP status light, off (SRM front panel).

5.4.5.

RECORD DMM indication in AS FOUND RESET column of Attachment 1, Section 3.0.

5.4.6.

VERIFY MONITOR STATUS, SRM C UPSC TRIP status lamp, off (SOURCE RANGE NEUTRON MONITORING section of MCP).

5.4.7.

While holding RESET switch on SRM front panel in TRIP, slowly ADJUST R10 CCW until UPSCALE ALARM status light, off (SRM front panel).

5.4.8.

RECORD DMM indication in AS FOUND RESET column of Attachment 1, Section 2.0.

5.4.9.

VERIFY the following:

Control Room annunciator C3 C1, SRM UPSCALE OR INOPERATIVE, off. (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, off (N/A if RPS MODE SWITCH in RUN)

LED, off (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

Computer point C015, SRM UPSC ALARM, not in alarm

MONITOR STATUS, SRM C UPSC AL OR INOP status lamp, off (SOURCE RANGE NEUTRON MONITORING section of MCP) 5.4.10.

IF data of Attachment 1, Sections 1.0 or 2.0 does NOT meet ACCEPTABLE VALUE criteria, NOTIFY Job Supervisor and SM/CRS that a Technical Specification ALLOWABLE VALUE has been exceeded.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 13 of 61 Rev. 27 5.5 Detector Not Full In/Retract Permit Test 5.5.1.

VERIFY SRM DETECTOR SELECT, C IN status lamp, on. (MCP)

CAUTION Detector drive damage may occur during detector drive-out if platform below reactor is not properly positioned.

5.5.2.

IF RPS MODE SWITCH is in RUN, REMOVE jumper installed between terminals AA-40 and AA-46, panel H21-P008 (as part of Step 5.1.18);

OTHERWISE REQUEST RO to drive out SRM C detector until SRM DETECTOR SELECT, C IN status lamp, off (MCP).

5.5.3.

Slowly ADJUST R10 CCW until RETR PERM DOWNSCALE status lamp, on (SRM front panel).

5.5.4.

RECORD DMM indication in AS FOUND TRIP column of Attachment 1, Section 4.0.

5.5.5.

VERIFY the following:

Control Room annunciator C3 E2, SRM DET REMOVAL NOT PERMITTED, on (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, on (N/A if RPS MODE SWITCH in RUN)

LED, on (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

Computer point C014, SRM DET NOT START-UP POS, in alarm (N/A if RPS MODE SWITCH in RUN)

SRM DETECTOR SELECT, C RETRACT PERMIT status lamp, off (MCP) 5.5.6.

REQUEST RO to place SRM C in bypass.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 14 of 61 Rev. 27 5.5.7.

VERIFY the following:

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, off (N/A if RPS MODE SWITCH in RUN)

LED, off (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

SRM DETECTOR SELECT, C RETRACT PERMIT status lamp, on (MCP) 5.5.8.

REQUEST RO to take SRM C out of bypass.

5.5.9.

VERIFY the following:

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, on (N/A if RPS MODE SWITCH in RUN)

LED, on (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

SRM DETECTOR SELECT, C RETRACT PERMIT status lamp, off (MCP) 5.5.10.

Slowly ADJUST R10 CW until RETR PERM DOWNSCALE status lamp, off (SRM front panel).

5.5.11.

RECORD DMM indication in AS FOUND RESET column of Attachment 1, Section 4.0.

5.5.12.

VERIFY the following:

SRM DETECTOR SELECT, C RETRACT PERMIT status lamp, on (MCP)

Computer point C014, SRM DET NOT START-UP POS, not in alarm (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C3 E2, SRM DET REMOVAL NOT PERMITTED, off (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, off (N/A if RPS MODE SWITCH in RUN)

LED, off (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN

HC.IC-CC.SE-0003(Q)

Hope Creek Page 15 of 61 Rev. 27 5.5.13.

REQUEST RO to withdraw SRM C detector until SRM DETECTOR SELECT, C OUT status lamp, on (MCP) (detector is full-out).

5.5.14.

VERIFY SRM DETECTOR SELECT, C RETRACT PERMIT status lamp, off. (MCP) 5.5.15.

IF RPS MODE SWITCH is in RUN, INSTALL 12 inch jumper between CV terminals AA-40 and AA-46 (panel H21-P008); OTHERWISE REQUEST RO to drive SRM C detector in until SRM DETECTOR SELECT, C IN status lamp, on (MCP) (detector is full-in).

5.5.16.

DISCONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.6 Period Trip Test 5.6.1.

ADJUST R10 to fully CCW.

5.6.2.

PLACE SRM C front panel selector switch to TRIP TEST (PER).

5.6.3.

CONNECT DMM between AR14-J1 (+) and VR29-J2 (-) on SRM C.

5.6.4.

Momentarily PLACE SRM C front panel RESET switch to TRIP.

5.6.5.

Slowly ADJUST R10 CW until PERIOD status lamp, on (SRM C front panel).

5.6.6.

RECORD DMM indication in AS FOUND TRIP column of Attachment 1, Section 5.0.

5.6.7.

VERIFY the following:

Control Room annunciator C3 D1, SRM PERIOD, on (N/A if RPS MODE SWITCH in RUN)

MONITOR STATUS, SRM C PERIOD status lamp, on (SOURCE RANGE NEUTRON MONITORING section of MCP) 5.6.8.

PLACE SRM C front panel selector switch to OPERATE.

5.6.9.

RELEASE INOP INHIBIT switch S4.

5.6.10.

Momentarily PLACE SRM C front panel RESET switch to TRIP.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 16 of 61 Rev. 27 5.6.11.

VERIFY the following:

Control Room annunciator C3 D1, SRM PERIOD, off (N/A if RPS MODE SWITCH in RUN)

MONITOR STATUS, SRM C PERIOD status lamp, off (SOURCE RANGE NEUTRON MONITORING section of MCP)

PERIOD status lamp, off (SRM C front panel) 5.6.12.

DISCONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

5.7 Inoperative Trip Test 5.7.1.

PLACE SRM C (Mode) selector switch S1 to TRIP TEST (LCR).

5.7.2.

ADJUST trip test potentiometer R10 in SRM C for an indication of 10 CPS on LCR front panel meter.

NOTE In the following steps the INOP INHIBIT switch must be held pressed until instructed to release. Installed clamp on INOP INHIBIT switch will maintain switch pressed.

5.7.3.

PRESS AND HOLD SRM C INOP INHIBIT switch S4.

5.7.4.

RESET SRM C by momentarily placing RESET switch on SRM front panel to TRIP.

5.7.5.

VERIFY the following:

Control Room annunciator C3 C1, SRM UPSCALE OR INOPERATIVE, off (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, off (N/A if RPS MODE SWITCH in RUN)

LED, off (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

Computer Point C016, SRM INOP TRIP, not in alarm

MONITOR STATUS, SRM C UPSC AL OR INOP status lamp, off (SOURCE RANGE NEUTRON MONITORING section of MCP)

INOP status lamp, off (SRM front panel)

HC.IC-CC.SE-0003(Q)

Hope Creek Page 17 of 61 Rev. 27 5.7.6.

RELEASE SRM C INOP INHIBIT switch S4.

5.7.7.

VERIFY the following:

Control Room annunciator C3 C1, SRM UPSCALE OR INOPERATIVE, on (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, on (N/A if RPS MODE SWITCH in RUN)

LED, on (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

Computer point C016, SRM INOP TRIP, in alarm

MONITOR STATUS, SRM C UPSC AL OR INOP, status lamp, on (SOURCE RANGE NEUTRON MONITORING section of MCP)

INOP status lamp, on (SRM front panel) 5.7.8.

PRESS AND HOLD SRM C INOP INHIBIT SWITCH S4.

5.7.9.

VERIFY the following:

Control Room annunciator C3 C1, SRM UPSCALE OR INOPERATIVE, off (N/A if RPS MODE SWITCH in RUN)

Control Room annunciator C6 D3, ROD OUT MOTION BLOCK, off (N/A if RPS MODE SWITCH in RUN)

LED, off (Activity Control No. 1, panel 10C616) (N/A if RPS MODE SWITCH not in RUN)

Computer Point C016, SRM INOP TRIP, not in alarm

MONITOR STATUS, SRM C UPSC AL OR INOP status lamp, off (SOURCE RANGE NEUTRON MONITORING section of MCP)

INOP status lamp, off (SRM front panel) 5.7.10.

PLACE SRM C (mode) selector switch S1 to OPERATE.

5.7.11.

RELEASE SRM C INOP INHIBIT switch S4.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 18 of 61 Rev. 27 5.8 Pre-Regulator (VR27) Test 5.8.1.

REQUEST RO to bypass SRM channel C.

5.8.2.

MEASURE voltage between P1-17 (+) and P1-3 (-) on plug-in adapter with DMM set to measure 20 VDC.

5.8.3.

RECORD DMM indication in AS FOUND +20.000 column of Attachment 1, Section 6.0.

5.8.4.

MEASURE voltage between P1-1 (+) and P1-3 (-) on plug-in adapter.

5.8.5.

RECORD DMM indication in AS FOUND -20.000 column of Attachment 1, Section 6.0.

5.9 Voltage Regulator (VR29) Test 5.9.1.

MEASURE voltage between J1 (+) and J2 (-) on voltage regulator with DMM set to measure 20 VDC.

5.9.2.

RECORD DMM indication in AS FOUND +15.000 column of Attachment 1, Section 7.0.

5.9.3.

MEASURE voltage between J3 (+) and J2 (-) on voltage regulator with DMM set to measure 20 VDC.

5.9.4.

RECORD DMM indication in AS FOUND -15.000 column of Attachment 1, Section 7.0.

5.10 Internal 10 and 105 Circuit Test 5.10.1.

CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.10.2.

CONNECT electronic counter to monitor period (seconds) to scaler output jack J8 at rear of SRM C drawer.

5.10.3.

PLACE SRM C front panel selector switch in 10.

5.10.4.

RECORD electronic counter period for 10 CPS in AS FOUND column of, Section 8.0.

5.10.5.

RECORD DMM indication for 10 CPS in AS FOUND column of Attachment 1, Section 8.0.

5.10.6.

PLACE SRM C front panel selector switch in 105.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 19 of 61 Rev. 27 5.10.7.

ADJUST electronic counter to monitor frequency (kHz) and RECORD electronic counter frequency for 105 CPS in AS FOUND column of, Section 8.0.

5.10.8.

RECORD DMM indication for 105 CPS in AS FOUND column of Attachment 1, Section 8.0.

5.10.9.

DISCONNECT electronic counter from scaler output jack J8 at rear of SRM C drawer.

5.11 Ramp Circuit Test 5.11.1.

PLACE SRM C front panel selector switch in PERIOD.

5.11.2.

HOLD SRM front panel RESET switch in RAMP position until DMM indicates as close to 0.000 VDC as possible.

NOTE A stopwatch will be required for the following step.

5.11.3.

Simultaneously START stopwatch AND HOLD front panel RAMP switch in FIXED position. STOP stopwatch when DMM indicates +7.140 VDC.

5.11.4.

RECORD time for voltage to go from 0.000 to +7.140 VDC in AS FOUND column of Attachment 1, Section 9.0.

5.12 LCR Front Panel Meter, Remote LCR Recorder and Computer Point B3029 Test 5.12.1.

PLACE SRM C front panel selector switch in TRIP TEST (LCR).

5.12.2.

ADJUST R10 in SRM drawer until LCR front panel meter indicates INPUT values specified in Attachment 1, Section 10.0. RECORD DMM indication in AS FOUND column for each input.

5.12.3.

ADJUST R10 in SRM drawer until Recorder H1SE -1SEXR-R602A-C51 (BLUE PEN) indicates INPUT values specified in Attachment 1, Section 11.0. RECORD DMM indication in AS FOUND column for each input.

5.12.4.

ADJUST R10 in SRM drawer until DMM indicates INPUT values specified in Attachment 1, Section 12.0. RECORD computer indication for computer point B3029 in AS FOUND column for each input.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 20 of 61 Rev. 27 5.13 LCR Amplifier (AR23) Zero and Period Amplifier (AR14) Zero Test 5.13.1.

PLACE SRM C front panel selector switch in ZERO.

5.13.2.

RECORD DMM indication in AS FOUND column of Attachment 1, Section 13.0.

5.13.3.

DISCONNECT DMM lead at AR23-J1 (+) and CONNECT lead to AR14-J1 (+).

5.13.4.

RECORD DMM indication in AS FOUND column of Attachment 1, Section 14.0.

5.14 Period Circuit Test 5.14.1.

PLACE SRM C front panel selector switch in PERIOD.

5.14.2.

PLACE SRM C front panel RESET switch in RAMP for approximately 5 seconds.

5.14.3.

HOLD SRM C front panel RAMP switch in FIXED.

5.14.4.

RECORD DMM indication in AS FOUND column of Attachment 1, Section 15.0.

5.14.5.

RELEASE SRM C front panel RAMP switch.

5.15 Period Front Panel Meter and Computer Point B3003 Test 5.15.1.

PLACE SRM C front panel selector switch to TRIP TEST (PER).

NOTE With selector switch in TRIP TEST (PER), test circuit will saturate after a period of time, depending on adjustment of R10. Placing RESET switch in RAMP for approximately 5 seconds will reset ramp circuit.

5.15.2.

ADJUST R10 in SRM drawer until PERIOD front panel meter indicates INPUT values specified in Attachment 1, Section 16.0. RECORD DMM indication in AS FOUND column for each input.

5.15.3.

ADJUST R10 in SRM drawer until DMM indicates INPUT values specified in Attachment 1, Section 17.0. RECORD computer indication for computer point B3003 in AS FOUND column for each input.

5.15.4.

DISCONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

HC.IC-CC.SE-0003(Q)

Hope Creek Page 21 of 61 Rev. 27 5.15.5.

PLACE SRM C front panel selector switch in OPERATE.

5.16 High Voltage and Inoperative Test NOTE If high voltage cannot be achieved, inform the Job Supervisor and/or Engineering that new and refurbished High Voltage power supplies typically arrive from the manufacturer with the voltage jumpered for 100 to 350 VDC operation. The jumper wire connected to J21-A3 must be removed for 350 to 600 VDC operation.

CAUTION High voltage is present at test points in the following step. Use caution to prevent injury.

5.16.1.

CONNECT DMM set to measure 600 VDC between PS21-TP1 (+) and VR29-J2 (-).

5.16.2.

RECORD DMM indication in AS FOUND OPER HV column of Attachment 1, Section 18.0.

5.16.3.

ADJUST R1 on High Voltage Power Supply module (PS21) to lower high voltage until INOP status lamp, on (front of SRM drawer).

5.16.4.

VERIFY INOP status lamp, on (SRM front panel).

5.16.5.

RECORD DMM indication in AS FOUND INOP TRIP column of, Section 18.0.

5.16.6.

ADJUST R1 until DMM indicates AS FOUND OPER. HV recorded on, Section 18.0, in Step 5.16.2.

5.16.7.

VERIFY INOP status lamp, off (SRM front panel).

5.16.8.

DISCONNECT DMM from SRM drawer.

5.16.9.

Using Fluke 45, RECORD ripple voltage between PS21-TP1 and VR29-J2 on Attachment 1.

5.16.10. IF ripple voltage is greater than tolerance specified, INITIATE a notification to repair/replace power supply. (This does not make the equipment unsatisfactory, power supply is operational.)

HC.IC-CC.SE-0003(Q)

Hope Creek Page 22 of 61 Rev. 27 5.17 Data Evaluation 5.17.1.

EVALUATE AS FOUND data recorded on Attachment 1, Sections 1.0 through 18.0. IF any AS FOUND data exceeds DESIRED RANGE, GO TO Section 5.18, Calibration Setup.

5.17.2.

IF all AS FOUND data is within DESIRED RANGE, RECORD data in AS LEFT column AND GO TO Section 5.54, Return to Service.

5.18 Calibration Setup NOTE Sections 8.1 through 8.4 show location of module adjustments.

5.18.1.

IF not done, REQUEST RO to bypass SRM channel C.

5.18.2.

PERFORM applicable calibration section(s) below, either as directed by each section, or at request of Job Supervisor.

5.19 Pre-Regulator (VR27) Calibration 5.19.1.

IF AS FOUND data in Attachment 1, Section 6.0 is within DESIRED RANGE, GO TO Section 5.20, Voltage Regulator (VR29) Calibration.

5.19.2.

MONITOR voltage between P1-17 (+) and P1-3 (-) on plug-in adapter with DMM (set to measure 20 VDC).

NOTE In Steps 5.19.3 and 5.19.5, use the following adjustment resistors as applicable for the installed pre-regulator:

GE Part # 234C5955G001 - R1 and R2 GE Part # 194X386G001, 194X386G002 - R9 and R20 5.19.3.

ADJUST R1 (R9) on pre-regulator for a (positive) DMM indication within CALIBRATION TOLERANCE of Attachment 1, Section 6.0.

5.19.4.

MONITOR voltage between P1-1 (+) and P1-3 (-) on plug-in adapter with DMM.

5.19.5.

ADJUST R2 (R20) on pre-regulator for a (negative) DMM indication within CALIBRATION TOLERANCE of Attachment 1, Section 6.0.

5.19.6.

DISCONNECT DMM from SRM drawer.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 23 of 61 Rev. 27 5.19.7.

IF further calibration is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.20 Voltage Regulator (VR29) Calibration 5.20.1.

IF AS FOUND data in Attachment 1, Section 7.0 is within DESIRED RANGE, GO TO Section 5.21, LCR Amplifier (AR23) Zero Calibration.

5.20.2.

LOCATE, LABEL AND REMOVE Voltage Regulator module (VR29) from PC SRM C drawer.

5.20.3.

REMOVE cover on voltage regulator, INSTALL it on second 129A2048G1 plug-in adapter AND INSTALL both module and adapter in SRM drawer.

5.20.4.

MONITOR voltage between J1 (+) and J2 (-) on voltage regulator with DMM set to measure 20 VDC.

5.20.5.

ADJUST R9 on voltage regulator for a (positive) DMM indication within CALIBRATION TOLERANCE of Attachment 1, Section 7.0.

5.20.6.

MONITOR voltage between J3 (+) and J2 (-) on voltage regulator with DMM.

5.20.7.

ADJUST R12 on regulator for a (negative) DMM indication within CALIBRATION TOLERANCE of Attachment 1, Section 7.0.

5.20.8.

DISCONNECT DMM from SRM drawer.

5.20.9.

REMOVE module and plug-in adapter, REPLACE cover, AND REPLACE module (VR29) in SRM drawer.

5.20.10. IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.21 LCR Amplifier (AR23) Zero Calibration 5.21.1.

IF AS FOUND data in Attachment 1, Section 13.0 is within DESIRED RANGE, GO TO Section 5.22, Period Amplifier (AR14) Zero Calibration.

5.21.2.

PLACE SRM C front panel selector switch in ZERO.

5.21.3.

CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.21.4.

ADJUST AR23-R20 on LCR Amplifier for a DMM indication of 0.000 (-0.001 to +0.001) VDC.

5.21.5.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 24 of 61 Rev. 27 5.22 Period Amplifier (AR14) Zero Calibration 5.22.1.

IF AS FOUND data in Attachment 1, Section 14.0 is within DESIRED RANGE, GO TO Section 5.23, Internal 10 and 105 Circuit Calibration.

5.22.2.

IF not done, PLACE SRM C front panel selector switch in ZERO.

5.22.3.

CONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

5.22.4.

ADJUST AR14-R22 on Period Amplifier for a DMM indication of 0.000 (-0.001 to +0.001) VDC.

5.22.5.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.23 Internal 10 and 105 Circuit Calibration 5.23.1.

IF AS FOUND data in Attachment 1, Section 8.0 is within DESIRED RANGE, GO TO Section 5.24, Ramp Circuit Calibration.

5.23.2.

LOCATE, LABEL AND REMOVE LCR Amplifier module (AR23) from PC SRM C drawer.

5.23.3.

REMOVE LCR Amplifier cover, INSTALL it on 129B2048G7 plug-in adapter, AND INSTALL both module and adapter in SRM drawer.

5.23.4.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.23.5.

CONNECT electronic counter to monitor period (seconds) to scaler output jack J8 at rear of SRM C drawer.

5.23.6.

PLACE SRM C front panel selector switch to 10.

5.23.7.

ADJUST Z24-R11 on Signal Generator module for an indication of 0.1000 (0.0998 to 0.1002) seconds on electronic counter.

5.23.8.

PLACE SRM C front panel selector switch in 105.

5.23.9.

ADJUST electronic counter to monitor frequency (kHz).

5.23.10. IF electronic counter does not indicate 100 (99.8 to 100.2) kHz, LOCATE, PC LABEL AND REMOVE Signal Generator module (Z24) from SRM C drawer.

5.23.11. REMOVE Signal Generator cover, INSTALL it on 129B2048G2 plug-in adapter, AND INSTALL both module and adapter in SRM drawer.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 25 of 61 Rev. 27 5.23.12. ADJUST Z24-C1 on Signal Generator module for an indication of 100 (99.8 to 100.2) kHz on electronic counter.

5.23.13. REPEAT Steps 5.23.5 through 5.23.12 as necessary, until electronic counter indications are within PERIOD and FREQ CALIBRATION TOLERANCE of Attachment 1, Section 8.0.

5.23.14. REMOVE Signal Generator module and plug-in adapter, REPLACE cover AND INSTALL Signal Generator module (Z24) in SRM drawer.

5.23.15. PLACE SRM C front panel selector switch in 10.

5.23.16. ADJUST Z13-R19 on Log Integrator module for a DMM indication of 2.86 (2.76 to 2.96) VDC.

5.23.17. PLACE SRM C front panel selector switch in 105.

5.23.18. ADJUST AR23-R7 on LCR Amplifier for a DMM indication of 8.57 (8.47 to 8.67) VDC.

5.23.19. REPEAT Steps 5.23.15 through 5.23.18 as necessary, until DMM indications are within VOLTS CALIBRATION TOLERANCE of, Section 8.0.

5.23.20. DISCONNECT DMM from SRM drawer.

5.23.21. DISCONNECT electronic counter from scaler output jack J8 at rear of SRM C drawer.

5.23.22. REMOVE LCR Amplifier module and plug-in adapter, REPLACE cover AND INSTALL LCR Amplifier module (AR23) in SRM drawer.

5.23.23. IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.24 Ramp Circuit Calibration 5.24.1.

IF AS FOUND data in Attachment 1, Section 9.0 is within DESIRED RANGE, GO TO Section 5.25, Period Circuit Calibration.

5.24.2.

PLACE SRM C front panel selector switch in PERIOD.

5.24.3.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.24.4.

ADJUST AR23-R1 on LCR Amplifier in direction required to raise (CCW) or lower (CW) period.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 26 of 61 Rev. 27 5.24.5.

HOLD SRM front panel RESET switch in RAMP until DMM indicates as close to 0.000 VDC as possible.

NOTE A stopwatch will be required for the following step.

5.24.6.

Simultaneously START stopwatch AND HOLD front panel RAMP switch in FIXED. STOP stopwatch when DMM indicates +7.140 VDC AND NOTE time.

5.24.7.

REPEAT Steps 5.24.4 through 5.24.6 as necessary, until time is within CALIBRATION TOLERANCE of Attachment 1, Section 9.0.

5.24.8.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.25 Period Circuit Calibration NOTE Adjustments made to Ramp circuit in Section 5.24 will affect AS FOUND data in Attachment 1, Section 15.0.

5.25.1.

IF AS FOUND data in Attachment 1, Section 15.0 is within DESIRED RANGE AND Section 5.24 was not performed, GO TO Section 5.26, Downscale Alarm Calibration.

5.25.2.

IF not done, PLACE SRM C front panel selector switch in PERIOD.

5.25.3.

IF not done, CONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

5.25.4.

PLACE SRM front panel RESET switch in RAMP for approximately 5 seconds.

NOTE Holding RAMP switch in FIXED position for more than two minutes will saturate test circuit.

Placing RESET switch in RAMP position for approximately 5 seconds will reset ramp circuit.

5.25.5.

HOLD SRM front panel RAMP switch in FIXED.

5.25.6.

ADJUST AR14-R2 on Period Amplifier for a DMM indication of

-10.000 (-9.980 to -10.020) VDC.

5.25.7.

RELEASE SRM front panel RAMP switch.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 27 of 61 Rev. 27 5.25.8.

REPEAT Steps 5.25.4 through 5.25.8 as necessary, until DMM indication is within CALIBRATION TOLERANCE of Attachment 1, Section 15.0.

5.25.9.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.26 Downscale Alarm Calibration 5.26.1.

IF AS FOUND data in Attachment 1, Section 1.0 is within DESIRED RANGE, GO TO Section 5.27, Upscale Alarm Calibration.

5.26.2.

IF not done, CONNECT a DMM between AR23-J1 (+) and VR29-J2 (-).

5.26.3.

PLACE SRM C front panel selector switch in TRIP TEST (LCR).

5.26.4.

ADJUST R10 to obtain a DMM indication within CALIBRATION TOLERANCE for DOWNSCALE trip setpoint.

5.26.5.

IF DOWNSCALE status lamp, on (front of SRM drawer), ADJUST Z15-R2 until DOWNSCALE status lamp, off.

5.26.6.

ADJUST Z15-R2 until front panel DOWNSCALE status lamp, on.

5.26.7.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.27 Upscale Alarm Calibration 5.27.1.

IF AS FOUND data in Attachment 1, Section 2.0 is within DESIRED RANGE, GO TO Section 5.28, Upscale Trip Calibration.

5.27.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.27.3.

IF not done, PLACE SRM C front panel selector switch in TRIP TEST (LCR).

5.27.4.

ADJUST R10 to obtain a DMM indication within CALIBRATION TOLERANCE for UPSCALE ALARM trip setpoint.

5.27.5.

IF UPSCALE ALARM status lamp, on (front of SRM drawer), HOLD front panel RESET switch in TRIP and if necessary, ADJUST Z15-R4 until front panel status lamp, off. RELEASE RESET switch.

5.27.6.

ADJUST Z15-R4 until front panel UPSCALE ALARM status lamp, on.

5.27.7.

While maintaining RESET switch in TRIP, ADJUST R10 until front panel UPSCALE ALARM status lamp, off. RELEASE RESET switch.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 28 of 61 Rev. 27 5.27.8.

Slowly ADJUST R10 until front panel UPSCALE ALARM status lamp, on.

5.27.9.

REPEAT Steps 5.27.4 through 5.27.8 as necessary, until trip setpoint is within CALIBRATION TOLERANCE of Attachment 1, Section 2.0.

5.27.10. IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.28 Upscale Trip Calibration 5.28.1.

IF AS FOUND data in Attachment 1, Section 3.0 is within DESIRED RANGE, GO TO Section 5.29, Retract Permit Downscale Calibration.

5.28.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.28.3.

IF not done, PLACE SRM C front panel selector switch in TRIP TEST (LCR).

5.28.4.

ADJUST R10 to obtain a DMM indication within CALIBRATION TOLERANCE for UPSCALE TRIP setpoint.

5.28.5.

IF UPSCALE TRIP status lamp, on (front of SRM drawer), HOLD front panel RESET switch in TRIP and if necessary, ADJUST Z15-R6 until front panel status lamp, off. RELEASE RESET switch.

5.28.6.

ADJUST Z15-R6 until front panel UPSCALE TRIP status lamp, on.

5.28.7.

While maintaining RESET switch in TRIP, ADJUST R10 until front panel UPSCALE TRIP status lamp, off. RELEASE RESET switch.

5.28.8.

Slowly ADJUST R10 until front panel UPSCALE TRIP status lamp, on.

5.28.9.

REPEAT Steps 5.28.4 through 5.28.8 as necessary, until trip setpoint is within CALIBRATION TOLERANCE of Attachment 1, Section 3.0.

5.28.10. IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.29 Retract Permit Downscale Calibration 5.29.1.

IF AS FOUND data in Attachment 1, Section 4.0 is within DESIRED RANGE, GO TO Section 5.30, Period Trip Calibration.

5.29.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.29.3.

IF not done, PLACE SRM C front panel selector switch in TRIP TEST (LCR).

HC.IC-CC.SE-0003(Q)

Hope Creek Page 29 of 61 Rev. 27 5.29.4.

ADJUST R10 to obtain a DMM indication within CALIBRATION TOLERANCE for RETRACT PERMIT DOWNSCALE trip setpoint.

5.29.5.

IF RETR PERM DOWNSCALE status lamp, on (front of SRM drawer),

ADJUST Z15-R3 until RETR PERM DOWNSCALE status lamp, off.

5.29.6.

ADJUST Z15-R3 until front panel RETR PERM DOWNSCALE status lamp, on.

5.29.7.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.30 Period Trip Calibration 5.30.1.

IF AS FOUND data in Attachment 1, Section 5.0 is within DESIRED RANGE, GO TO Section 5.31, LCR Front Panel Meter M1 Calibration.

5.30.2.

IF not done, CONNECT a DMM between AR14-J1 (+) and VR29-J2 (-).

5.30.3.

PLACE SRM C selector switch to TRIP TEST (PER).

NOTE With selector switch in TRIP TEST (PER) position, test circuit will saturate after a period of time, depending on adjustment of R10. Placing RESET switch in RAMP for approximately 5 seconds will reset ramp circuit.

5.30.4.

ADJUST R10 to obtain a DMM indication within CALIBRATION TOLERANCE for PERIOD trip setpoint.

5.30.5.

IF PERIOD status lamp, on (front of SRM drawer), HOLD front panel RESET switch in TRIP and if necessary, ADJUST Z15-R5 until front panel status lamp, off. RELEASE RESET switch.

5.30.6.

ADJUST Z15-R5 until front panel PERIOD status lamp, on.

5.30.7.

While maintaining RESET switch in TRIP, ADJUST R10 until front panel PERIOD status lamp, off. RELEASE RESET switch.

5.30.8.

Slowly ADJUST R10 until front panel PERIOD status lamp, on.

5.30.9.

REPEAT Steps 5.30.4 through 5.30.8 as necessary, until trip setpoint is within CALIBRATION TOLERANCE.

5.30.10. IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 30 of 61 Rev. 27 5.31 LCR Front Panel Meter M1 Calibration 5.31.1.

IF AS FOUND data in Attachment 1, Section 10.0 is within DESIRED RANGE, GO TO Section 5.32, Remote LCR Recorder Calibration.

5.31.2.

REMOVE pre-regulator and plug-in adapter from SRM C drawer.

5.31.3.

ADJUST mechanical zero on LCR front panel meter M1 to indicate precisely 10-1 CPS.

5.31.4.

INSTALL pre-regulator and plug-in adapter into SRM drawer.

5.31.5.

IF not done, CONNECT a DMM between AR23-J1 (+) and VR29-J2 (-).

5.31.6.

IF not done, PLACE SRM C selector switch to TRIP TEST (LCR).

5.31.7.

ADJUST R10 to obtain a DMM indication of 10.000 (9.900 to 10.100) VDC.

5.31.8.

ADJUST AR23-R22 on LCR Amplifier until LCR front panel meter indicates 106 CPS.

5.31.9.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.32 Remote LCR Recorder Calibration 5.32.1.

IF AS FOUND data in Attachment 1, Section 11.0 is within DESIRED RANGE, GO TO Section 5.33, Computer Point B3029 Calibration.

5.32.2.

IF Recorder H1SE -1SEXR-R602A-C51(Blue) requires calibration, NOTIFY Job Supervisor that HC.IC-DC.ZZ-0348(Q) must be performed AND NOTE in COMMENTS section of Attachment 2.

5.32.3.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 31 of 61 Rev. 27 5.33 Computer Point B3029 Calibration 5.33.1.

IF AS FOUND data in Attachment 1, Section 12.0 is within DESIRED RANGE, GO TO Section 5.34, Period Front Panel Meter M2 Calibration.

5.33.2.

IF computer point B3029 requires calibration AND AS FOUND data in, Section 10.0 is within DESIRED RANGE, INITIATE a notification to Digital Systems Group that PIU potentiometer for B3029 may require adjustment and/or B3029 requires calibration AND NOTE in COMMENTS section of ADMINISTRATIVE DATA PACKAGE.

5.33.3.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.34 Period Front Panel Meter M2 Calibration 5.34.1.

IF AS FOUND data in Attachment 1, Section 16.0 is within DESIRED RANGE, GO TO Section 5.35, Computer Point B3003 Calibration.

5.34.2.

LOCATE, LABEL AND REMOVE Period Amplifier module (AR14) from PC SRM C drawer.

5.34.3.

ADJUST mechanical zero on PERIOD front panel meter M2 to indicate precisely -100 SECONDS.

5.34.4.

REMOVE Period Amplifier cover, INSTALL it on 129B2048G2 plug-in adapter, AND INSTALL both module and adapter in SRM drawer.

5.34.5.

IF not done, CONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

5.34.6.

IF not done, PLACE SRM C selector switch to TRIP TEST (PER).

NOTE With selector switch in TRIP TEST (PER), the test circuit will saturate after a period of time, depending on adjustment of R10. Placing RESET switch in RAMP for approximately 5 seconds will reset ramp circuit.

5.34.7.

ADJUST R10 to obtain a DMM indication of +1.000 (+0.900 to +1.100)

VDC.

5.34.8.

ADJUST AR14-R16 on Period Amplifier until PERIOD front panel meter indicates -100 SECONDS.

5.34.9.

ADJUST R10 to obtain a DMM indication of -10.000 (-9.900 to -10.100)

VDC.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 32 of 61 Rev. 27 5.34.10. ADJUST AR14-R23 on Period Amplifier until PERIOD front panel meter indicates 10 SECONDS.

5.34.11. REPEAT Steps 5.34.7 through 5.34.10 as necessary, until no further adjustment is required.

5.34.12. REMOVE Period Amplifier module and plug-in adapter, REPLACE cover AND INSTALL Period Amplifier module (AR14) in SRM drawer.

5.34.13. IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

5.35 Computer Point B3003 Calibration 5.35.1.

IF AS FOUND data in Attachment 1, Section 17.0 is within DESIRED RANGE, GO TO Section 5.36, Low High Voltage Inoperative Trip Calibration.

5.35.2.

IF computer point B3003 requires calibration AND AS FOUND data in, Section 16.0 is within DESIRED RANGE, INITIATE a notification to Digital Systems Group that PIU potentiometer for B3003 may require adjustment and/or B3003 requires calibration AND NOTE in COMMENTS section of ADMINISTRATIVE DATA PACKAGE.

5.35.3.

IF further calibration of SRM is required, GO TO applicable section(s) of calibration; OTHERWISE GO TO Section 5.37, Data Verification.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 33 of 61 Rev. 27 5.36 Low High Voltage Inoperative Trip Calibration NOTE This section is to be performed only if Low High Voltage INOP TRIP requires calibration.

Calibration of OPER. HV will be performed in Section 5.37, Data Verification.

5.36.1.

IF AS FOUND INOP TRIP data in Attachment 1, Section 18.0 is within DESIRED RANGE, GO TO Section 5.37, Data Verification.

5.36.2.

IF not done, PLACE SRM C front panel selector switch in OPERATE.

CAUTION High voltage is present at test points in the following step. Use caution to prevent injury.

5.36.3.

CONNECT DMM set to measure 600 VDC between PS21-TP1 (+) and VR29-J2 (-).

5.36.4.

ADJUST R1 on High Voltage Power Supply module (PS21) until DMM indicates an INOP TRIP setpoint voltage that is within CALIBRATION TOLERANCE on Attachment 1, Section 18.0.

5.36.5.

IF INOP status lamp, on (front of SRM drawer), ADJUST Z15-R1 until INOP status lamp, off.

5.36.6.

ADJUST Z15-R1 until INOP status lamp, on (front of SRM drawer).

5.36.7.

ADJUST R1 on High Voltage Power Supply until front panel INOP status lamp, off.

5.36.8.

Slowly ADJUST R1 until front panel INOP status lamp, on (High Voltage Power Supply).

5.36.9.

REPEAT Steps 5.36.4 through 5.36.8 as necessary, until trip setpoint is within CALIBRATION TOLERANCE of Attachment 1, Section 18.0.

5.36.10. ADJUST R1 until front panel INOP status lamp, off (High Voltage Power Supply).

5.36.11. DISCONNECT DMM from SRM drawer.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 34 of 61 Rev. 27 5.37 Data Verification Setup 5.37.1.

IF not done, REQUEST RO to bypass SRM C.

5.37.2.

IF not done, PLACE SRM C front panel selector switch in OPERATE.

5.37.3.

REQUEST Job Supervisor to review Calibration sections of this test and determine which Data Verification sections should be performed because associated component(s) may have been affected by calibration of another component.

5.38 Pre-Regulator (VR27) Verification 5.38.1.

IF pre-regulator was calibrated, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of, Section 6.0 and GO TO Section 5.39, Voltage Regulator (VR29) Verification.

5.38.2.

MEASURE voltage between P1-17 (+) and P1-3 (-) on plug-in adapter with DMM (20 VDC) AND NOTE +20.000 DMM indication.

5.38.3.

MEASURE voltage between P1-1 (+) and P1-3 (-) on plug-in adapter AND NOTE -20.000 VDC DMM indication.

5.38.4.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 6.0.

5.38.5.

REMOVE Pre-Regulator module and plug-in adapter AND INSTALL IV Pre-Regulator module in SRM drawer.

5.39 Voltage Regulator (VR29) Verification 5.39.1.

IF voltage regulator was calibrated OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 7.0 AND GO TO Section 5.40, LCR Amplifier (AR23) Zero Verification.

5.39.2.

MEASURE voltage between J1 (+) and J2 (-) on voltage regulator with DMM (20 VDC) AND NOTE +15.000 DMM indication.

5.39.3.

MEASURE voltage between J3 (+) and J2 (-) on voltage regulator with DMM AND NOTE -15.000 DMM indication.

5.39.4.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 7.0.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 35 of 61 Rev. 27 5.40 LCR Amplifier (AR23) Zero Verification 5.40.1.

IF LCR Amplifier (AR23) zero was calibrated OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE, RECORD AS FOUND data in AS LEFT column of Attachment 1, Section 13.0 AND GO TO Section 5.41, Period Amplifier (AR14) Zero Verification.

5.40.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.40.3.

PLACE SRM C front panel selector switch in ZERO AND NOTE DMM indication.

5.40.4.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT column of, Section 13.0.

5.41 Period Amplifier (AR14) Zero Verification 5.41.1.

IF Period Amplifier (AR14) zero was calibrated OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT column of Attachment 1, Section 14.0 AND GO TO Section 5.42, Internal 10 and 105 Circuit Verification.

5.41.2.

IF not done, CONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

5.41.3.

PLACE SRM C front panel selector switch in ZERO AND NOTE DMM indication.

5.41.4.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT column of, Section 14.0.

5.42 Internal 10 and 105 Circuit Verification 5.42.1.

IF Internal 10 and 105 circuit was calibrated OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 8.0 AND GO TO Section 5.43, Ramp Circuit Verification.

5.42.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.42.3.

CONNECT electronic counter to monitor period (seconds) to scaler output jack J8 at rear of SRM C drawer.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 36 of 61 Rev. 27 5.42.4.

PLACE SRM C front panel selector switch in 10 AND NOTE electronic counter period and DMM indication.

5.42.5.

ADJUST electronic counter to monitor frequency (kHz).

5.42.6.

PLACE SRM front panel selector switch in 105 AND NOTE electronic counter frequency and DMM indication.

5.42.7.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 8.0.

5.42.8.

DISCONNECT electronic counter from scaler output jack J8 at rear of SRM C drawer.

5.43 Ramp Circuit Verification 5.43.1.

IF Ramp circuit was calibrated OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT column of Attachment 1, Section 9.0 AND GO TO Section 5.44, Period Circuit Verification.

5.43.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.43.3.

IF not done, PLACE SRM C front panel selector switch in PERIOD.

5.43.4.

HOLD SRM front panel RESET switch in RAMP position until DMM indicates as close to 0.000 VDC as possible.

NOTE A stopwatch will be required for the following step.

5.43.5.

Simultaneously START stopwatch AND HOLD front panel RAMP switch in FIXED. STOP stopwatch when DMM indicates +7.140 VDC AND NOTE time.

5.43.6.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT column of, Section 9.0.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 37 of 61 Rev. 27 5.44 Period Circuit Verification 5.44.1.

IF Period circuit was calibrated OR may have been affected by calibration of another component (e.g., Ramp circuit), as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT column of Attachment 1, Section 15.0 AND GO TO Section 5.45, Downscale Alarm Verification.

5.44.2.

IF not done, CONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

5.44.3.

IF not done, PLACE SRM front panel selector switch in PERIOD.

5.44.4.

PLACE SRM front panel RESET switch in RAMP for approximately 5 seconds.

5.44.5.

HOLD SRM front panel RAMP switch in FIXED AND NOTE DMM indication.

5.44.6.

RELEASE SRM front panel RAMP switch.

5.44.7.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT column of, Section 15.0.

5.45 Downscale Alarm Verification 5.45.1.

IF Downscale trip or reset point was calibrated OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 1.0 AND GO TO Section 5.46, Upscale Alarm Verification.

5.45.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.45.3.

IF not done, PLACE SRM C front panel selector switch in TRIP TEST (LCR).

5.45.4.

ADJUST R10 to obtain an indication of 10 CPS on LCR front panel meter.

5.45.5.

Slowly ADJUST R10 until DOWNSCALE status lamp, on (SRM front panel)

AND NOTE TRIP DMM indication.

5.45.6.

ADJUST R10 until DOWNSCALE status lamp, off AND NOTE RESET DMM indication.

5.45.7.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 1.0.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 38 of 61 Rev. 27 5.46 Upscale Alarm Verification 5.46.1.

IF Upscale Alarm was calibrated OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 2.0 AND GO TO Section 5.47, Upscale Trip Verification.

5.46.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.46.3.

IF not done, PLACE SRM C front panel selector switch in TRIP TEST (LCR).

5.46.4.

ADJUST R10 to obtain an indication of 10 CPS on LCR front panel meter.

5.46.5.

Momentarily PLACE RESET switch on SRM front panel in TRIP.

5.46.6.

Slowly ADJUST R10 CW until UPSCALE ALARM status lamp, on (SRM front panel) AND NOTE TRIP DMM indication.

5.46.7.

HOLD RESET switch on SRM front panel in TRIP.

5.46.8.

Slowly ADJUST R10 CCW until UPSCALE ALARM status lamp, off (SRM front panel) AND NOTE RESET DMM indication.

5.46.9.

RELEASE RESET switch on SRM front panel.

5.46.10. IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 2.0.

5.47 Upscale Trip Verification 5.47.1.

IF Upscale Trip was calibrated OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 3.0 AND GO TO Section 5.48, Retract Permit Downscale Verification.

5.47.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.47.3.

IF not done, PLACE SRM C front panel selector switch in TRIP TEST (LCR).

5.47.4.

ADJUST R10 to obtain an indication of 10 CPS on LCR front panel meter.

5.47.5.

Momentarily PLACE RESET switch on SRM front panel in TRIP.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 39 of 61 Rev. 27 5.47.6.

Slowly ADJUST R10 CW until UPSCALE TRIP status lamp, on (SRM front panel) AND NOTE TRIP DMM indication.

5.47.7.

HOLD RESET switch on SRM front panel in TRIP.

5.47.8.

Slowly ADJUST R10 CCW until UPSCALE TRIP status lamp, off (SRM front panel) AND NOTE RESET DMM indication.

5.47.9.

RELEASE RESET switch on SRM front panel.

5.47.10. IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 3.0.

5.48 Retract Permit Downscale Verification 5.48.1.

IF Retract Permit Downscale trip or reset point was calibrated, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 4.0 AND GO TO Section 5.49, Period Trip Verification.

5.48.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.48.3.

IF not done, PLACE SRM C front panel selector switch in TRIP TEST (LCR).

5.48.4.

IF necessary, ADJUST R10 CW until RETR PERM DOWNSCALE status light, off (SRM front panel).

5.48.5.

Slowly ADJUST R10 CCW until RETR PERM DOWNSCALE status light, on (SRM front panel) AND NOTE TRIP DMM indication.

5.48.6.

Slowly ADJUST R10 CW until RETR PERM DOWNSCALE status light, off (SRM front panel) AND NOTE RESET DMM indication.

5.48.7.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 4.0.

5.49 Period Trip Verification 5.49.1.

IF Period Trip was calibrated, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT column of, Section 5.0 AND GO TO Section 5.50, Low High Voltage Inoperative Circuit Verification.

5.49.2.

IF not done, CONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

HC.IC-CC.SE-0003(Q)

Hope Creek Page 40 of 61 Rev. 27 5.49.3.

ADJUST R10 to fully CCW.

5.49.4.

IF not done, PLACE SRM C front panel selector switch in TRIP TEST (PER).

5.49.5.

Momentarily PLACE RESET switch to TRIP.

5.49.6.

Slowly ADJUST R10 CW until PERIOD status lamp, on (SRM front panel)

AND NOTE DMM indication.

5.49.7.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT column of, Section 4.0 5.50 Low High Voltage Inoperative Circuit Verification 5.50.1.

IF low high voltage inoperative trip circuit was calibrated OR AS FOUND OPER. HV recorded on Attachment 1, Section 18.0 is not within DESIRED RANGE OR may have been affected by calibration of another component, as determined by Job Supervisor, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns AND GO TO Section 5.51, Remote LCR Recorder Verification.

5.50.2.

CONNECT DMM set to measure 600 VDC between PS21-TP1 (+) and VR29-J2 (-).

5.50.3.

IF not done, PLACE SRM C front panel selector switch in OPERATE.

5.50.4.

IF low high voltage inoperative trip was calibrated OR may have been affected by calibration of another component, slowly ADJUST R1 on high voltage supply to lower high voltage until INOP status lamp, on (front of SRM drawer) AND NOTE INOP TRIP DMM indication; OTHERWISE RECORD AS FOUND INOP TRIP data in AS LEFT column of Attachment 1, Section 18.0 AND GO TO Step 5.50.6.

5.50.5.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT INOP TRIP column of Attachment 1, Section 18.0.

5.50.6.

ADJUST R1 until DMM indicates a value within CALIBRATION TOLERANCE of Attachment 1, Section 18.0 AND RECORD voltage in AS LEFT OPER. HV column.

5.50.7.

DISCONNECT DMM from SRM drawer.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 41 of 61 Rev. 27 5.51 Remote LCR Recorder Verification 5.51.1.

IF remote recorder H1SE -1SEXR-R602A-C51(Blue) was calibrated, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 11.0 AND GO TO Section 5.52, LCR Front Panel Meter M1 and Computer Point B3029 Verification.

5.51.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.51.3.

IF not done, PLACE SRM C front panel selector switch to TRIP TEST (LCR).

5.51.4.

ADJUST R10 in SRM C drawer until remote Recorder H1SE

-1SEXR-R602A-C51 (Blue) indicates INPUTS specified in Attachment 1, Section 11.0 AND NOTE DMM indication.

5.51.5.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 11.0.

5.51.6.

IF Recorder H1SE -1SEXR-R602A-C51 was removed for calibration, VERIFY with RO, the indication of other pens on recorder are consistent with plant conditions.

5.52 LCR Front Panel Meter M1 and Computer Point B3029 Verification 5.52.1.

IF LCR front panel meter M1 was calibrated, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 10.0 AND GO TO Section 5.53, Period Front Panel Meter M2 and Computer Point B3003 Verification.

5.52.2.

IF not done, CONNECT DMM between AR23-J1 (+) and VR29-J2 (-).

5.52.3.

IF not done, PLACE SRM C selector switch to TRIP TEST (LCR).

5.52.4.

ADJUST R10 until LCR front panel meter M1 indicates each INPUT specified in Attachment 1, Section 10.0 AND NOTE indication on DMM.

5.52.5.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 10.0.

5.52.6.

ADJUST R10 until DMM indicates each INPUT specified in Attachment 1, Section 12.0 AND NOTE computer indication for computer point B3029, SRM CH C COUNT RATE.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 42 of 61 Rev. 27 5.52.7.

IF alignment/calibration was successful in correcting data (or maintaining affected data, as applicable) to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of Attachment 1, Section 12.0.

5.52.8.

IF computer point B3029 requires calibration, if not done, INITIATE a Notification to Digital Systems Group that PIU potentiometer for B3029 may require adjustment and/or B3029 requires calibration AND NOTE in COMMENTS section of ADMINISTRATIVE DATA PACKAGE.

5.53 Period Front Panel Meter M2 and Computer Point B3003 Verification 5.53.1.

IF Period front panel meter M2 was calibrated, PERFORM remaining steps of this section; OTHERWISE RECORD AS FOUND data in AS LEFT columns of Attachment 1, Section 16.0 AND GO TO Section 5.54, Return to Service.

5.53.2.

IF not done, CONNECT DMM between AR14-J1 (+) and VR29-J2 (-).

5.53.3.

IF not done, PLACE SRM C selector switch to TRIP TEST (PER).

NOTE With selector switch in TRIP TEST (PER), the test circuit will saturate after a period of time, depending on adjustment of R10. Placing RESET switch in RAMP position for approximately 5 seconds will reset ramp circuit.

5.53.4.

ADJUST R10 in SRM C drawer until PERIOD front panel meter M2 indicates each INPUT specified in Attachment 1, Section 16.0 AND NOTE indication on DMM.

5.53.5.

IF alignment/calibration was successful in correcting data to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of, Section 16.0.

5.53.6.

ADJUST R10 until DMM indicates each INPUT specified in Attachment 1, Section 17.0 AND NOTE computer indication for computer point B3003, SRM CHANNEL C PERIOD.

5.53.7.

IF alignment/calibration was successful in correcting data (or maintaining affected data, as applicable) to within CALIBRATION TOLERANCE, RECORD data in AS LEFT columns of Attachment 1, Section 17.0.

5.53.8.

IF computer point B3003 requires calibration, if not done, INITIATE a Notification to Digital Systems Group that PIU potentiometer for B3003 may require adjustment and/or B3003 requires calibration AND NOTE in COMMENTS section of ADMINISTRATIVE DATA PACKAGE.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 43 of 61 Rev. 27 5.54 Return to Service 5.54.1.

DISCONNECT all test equipment from SRM C drawer.

5.54.2.

IF not done, REMOVE Pre-Regulator module and plug-in adapter AND IV INSTALL Pre-Regulator module in SRM C drawer.

5.54.3.

IF RPS MODE SWITCH was in RUN and Step 5.1.13 was performed to prepare SRM for OPERATIONAL CONDITION 1 testing, PERFORM the following:

REMOVE jumper installed between terminals AA-40 and AA-46 IV (panel H21-P008)

REMOVE SRM Test Relay from K17 socket in TRIP AUX UNIT C IV (panel 10C636) AND INSTALL K17

REMOVE jumper connected between terminal TB4-10 (TRIP AUX IV UNIT A) and terminal BB-96 (panel 10C635)

REMOVE jumper connected between TB4-7 (TRIP AUX UNIT A)

IV and CC-89 (panel 10C635) 5.54.4.

VERIFY each of the following modules is installed in SRM C drawer:

Voltage Regulator module (VR29)

IV

LCR Amplifier module (AR23)

IV

Period Amplifier module (AR14)

IV

Signal Generator module (Z24)

IV 5.54.5.

IF not done, PLACE each of the following SRM C switches in the stated position:

Front panel selector switch in OPERATE.

IV INOP INHIBIT switch released and clamp removed.

IV 5.54.6.

REQUEST RO to verify SRM C detector is correctly positioned for present RO plant operating condition.

HC.IC-CC.SE-0003(Q)

Hope Creek Page 44 of 61 Rev. 27 5.54.7.

VERIFY LCR meter reading on front of SRM C drawer is consistent with value recorded in Step 5.1.10 AND/OR present plant conditions.

5.54.8.

REQUEST RO to PLACE IRM RANGE SELECT, CHANNEL A Range Switch in desired range position for present plant operating condition.

5.54.9.

Momentarily PLACE RESET switch on front of SRM C drawer in TRIP.

5.54.10. REQUEST RO to remove SRM channel C from bypass.

5.54.11. NOTIFY RO that channel has been returned to service.

5.54.12. NOTIFY SM/CRS this test has been completed and channel returned to service OR committed to rework.

END OF PROCEDURE SECTION

HC.IC-CC.SE-0003(Q)

Hope Creek Page 45 of 61 Rev. 27 6.0 RECORDS RETAIN entire procedure

7.0 REFERENCES

7.1 Technical Specifications 4.3.6, Control Rod Block Instrumentation

4.3.7.6, Source Range Monitors 4.9.2, Refueling Operations 7.2 Drawings Startup Range Neutron Monitor System, PN1-C51-1070-0021, 791E410AC(GE)

Sheets 2, 4, 5, 10, 11, 12, 13 Startup Range Detector Drive Control Sys, PN1-C51-1050-0020, 791E412AC(GE) Sheets 1, 2, 3 Reactor Manual Control System, PN1-C11-1050-0095, 791E406AC(GE)

Sheets 14, 24 Overhead Annunciator System; J-3000-1, Sheet 10, 12 Panel Arrangement 10C650 - Main Vertical Boards Legends; J-0650-1, Sheet 9 Panel Arrangement 10C651 - Unit Operators Console Legends; J-0651-1, Sheet 6, 7 7.3 Manuals GEK-73632B, Source Range Monitor, Bechtel SDR# N1-A41-8010-49(1) 7.4 Notifications/Orders 80074146, Ripple Voltage 70044093-0040, HVPS jumper configuration for 350 - 600 VDC operation 70046169, IRM CHANNEL CAL PROCEDURES UNSAT (Correct Purpose Section)

CRCA 70027972, Unexpected Half-Scram During IRM Testing

HC.IC-CC.SE-0003(Q)

Hope Creek Page 46 of 61 Rev. 27 7.5 Others Computer Input/Output Summary for Hope Creek Generating Station; J-0625-0 Setpoint Calculation # SC-SE-0001 DCP 4EC-1082 package # 08.

7.6 Cross-References

MA-AA-716-009, Use of Maintenance Procedures HC.IC-DC.ZZ-0348(Q), Honeywell Minitrend Recorder Calibration

HC.IC-CC.SE-0003(Q)

Hope Creek Page 47 of 61 Rev. 27 8.0 REFERENCE DRAWINGS 8.1 VOLTAGE REGULATOR

HC.IC-CC.SE-0003(Q)

Hope Creek Page 48 of 61 Rev. 27 8.2 LCR Amplifier

HC.IC-CC.SE-0003(Q)

Hope Creek Page 49 of 61 Rev. 27 8.3 SIGNAL GENERATOR MODULE

HC.IC-CC.SE-0003(Q)

Hope Creek Page 50 of 61 Rev. 27 8.4 PERIOD GENERATOR MODULE

HC.IC-CC.SE-0003(Q)

Hope Creek Page 51 of 61 Rev. 27 ATTACHMENT 1 1.0 (Steps 5.2.2, 5.2.5) H1SE -1SEXSL-Z16SRCC51, DOWNSCALE TRIP TECHNICAL SPECIFICATION VALUE ACCEPTABLE VALUE is: $ 1.793 DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO TRIP $

2.110 2.352 2.110 2.281 RESET N/A N/A N/A N/A 2.0 (Steps 5.3.2, 5.4.8) H1SE -1SEXSHL-Z17SRCC51, UPSCALE ALARM TECHNICAL SPECIFICATION VALUE ACCEPTABLE VALUE is: # 8.863 DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO TRIP $

8.330 8.572 8.401 8.572 RESET N/A N/A N/A N/A 3.0 (Steps 5.4.2, 5.4.5) H1SE -1SEXS-Z18SRCC51, UPSCALE TRIP DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO TRIP 8.760 9.244 8.831 9.173 RESET N/A N/A N/A N/A

HC.IC-CC.SE-0003(Q)

Hope Creek Page 52 of 61 Rev. 27 ATTACHMENT 1 4.0 (Steps 5.5.4, 5.5.11) H1SE -1SEXSHL-Z17SRCC51, RETRACT PERMIT DOWNSCALE DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO TRIP 4.044 4.528 4.115 4.457 RESET N/A N/A N/A N/A 5.0 (Step 5.6.6) H1SE -1SEXS-Z18SRCC51, PERIOD DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO TRIP

-1.717

-2.283

-1.800

-2.200 6.0 (Steps 5.8.3, 5.8.5) H1SE -1SEVR-27SRMCC51, VOLTAGE PRE-REGULATOR (VR27)

DESIRED (VDC)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO

+20.000 19.800 20.200 19.800 20.200

-20.000

-19.800

-20.200

-19.800

-20.200

HC.IC-CC.SE-0003(Q)

Hope Creek Page 53 of 61 Rev. 27 ATTACHMENT 1 7.0 (Steps 5.9.2, 5.9.4) H1SE -1SEVR-29SRMCC51, VOLTAGE REGULATOR (VR29)

DESIRED (VDC)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO

+15.000 14.900 15.100 14.900 15.100

-15.000

-14.900

-15.100

-14.900

-15.100 8.0 (Steps 5.10.4, 5.10.5, 5.10.7, 5.10.8) H1SE -1SEXAM-AR23C-C51, INTERNAL 10 AND 105 CIRCUIT PARAMETER DESIRED DESIRED RANGE AS FOUND CALIBRATION TOLERANCE AS LEFT FROM TO FROM TO 10 CPS PERIOD 0.1000 SEC 0.0998 0.1002 0.0998 0.1002 VOLTS 2.860 VDC 2.760 2.960 2.760 2.960 105 CPS FREQ 100.0 kHz 99.8 100.2 99.8 100.2 VOLTS 8.570 VDC 8.470 8.670 8.470 8.670

HC.IC-CC.SE-0003(Q)

Hope Creek Page 54 of 61 Rev. 27 ATTACHMENT 1 9.0 (Step 5.11.4) H1SE -1SEXAM-AR23C-C51, RAMP CIRCUIT RAMP PERIOD (seconds)

DESIRED RANGE (seconds)

AS FOUND CALIBRATION TOLERANCE (seconds)

AS LEFT FROM TO FROM TO 115.0 113.0 117.0 113.0 117.0 10.0 (Step 5.12.2) H1SE -1SEXI-M1SRMCC51, LCR FRONT PANEL METER M1 INPUT (CPS)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO 10-1

-0.141 0.141

-0.100 0.100 10 2.716 2.998 2.757 2.957 103 5.573 5.855 5.614 5.814 105 8.430 8.712 8.471 8.671 106 9.859 10.141 9.900 10.100 105 8.430 8.712 8.471 8.671 103 5.573 5.855 5.614 5.814 10 2.716 2.998 2.757 2.957 10-1

-0.141 0.141

-0.100 0.100

HC.IC-CC.SE-0003(Q)

Hope Creek Page 55 of 61 Rev. 27 ATTACHMENT 1 11.0 (Step 5.12.3) H1SE -1SEXR-R602A-C51, (BLUE) RECORDER INPUT (CPS)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO 10-1

-0.070 0.070

-0.050 0.050 10 2.787 2.927 2.807 2.907 103 5.644 5.784 5.664 5.764 105 8.502 8.642 8.522 8.622 106 9.930 10.070 9.950 10.050 105 8.502 8.642 8.522 8.622 103 5.644 5.784 5.664 5.764 10 2.787 2.927 2.807 2.907 10-1

-0.070 0.070

-0.050 0.050 Calibrate to Numeric Display 12.0 (Step 5.12.4) COMPUTER POINT: B3029, SRM CH C COUNT RATE DESIRED RANGE (CPS1)

AS FOUND CALIBRATION TOLERANCE (CPS1)

AS LEFT FROM TO FROM TO 0.00 0.0617 0.162 0.0617 0.162 10.00 617000 1620000 617000 1620000 1 +/- 3.0% Equivalent Linear Full Scale

HC.IC-CC.SE-0003(Q)

Hope Creek Page 56 of 61 Rev. 27 ATTACHMENT 1 13.0 (Step 5.13.2) H1SE -1SEXAM-AR23C-C51, LCR AMPLIFIER ZERO DESIRED (VDC)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO 0.000

-0.001 0.001

-0.001 0.001 14.0 (Step 5.13.4) H1SE -1SEXAM-AR14C-C51, PERIOD AMPLIFIER ZERO DESIRED (VDC)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO 0.000

-0.001 0.001

-0.001 0.001 15.0 (Step 5.14.4) H1SE -1SEXAM-AR14C-C51, PERIOD CIRCUIT PARAMETER (PERIOD)

DESIRED (VDC)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO 10 SECONDS

-10.000

-9.980

-10.020

-9.980

-10.020

HC.IC-CC.SE-0003(Q)

Hope Creek Page 57 of 61 Rev. 27 ATTACHMENT 1 16.0 (Step 5.15.2) H1SE -1SEXI-M2SRMCC51, PERIOD FRONT PANEL METER M2 INPUT (SECONDS)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO

-100 0.859 1.141 0.900 1.100 INFINITY

-0.141 0.141

-0.100 0.100 10

-9.859

-10.141

-9.900

-10.100 INFINITY

-0.141 0.141

-0.100 0.100

-100 0.859 1.141 0.900 1.100 17.0 (Step 5.15.3) COMPUTER POINT: B3003, SRM CHANNEL C PERIOD INPUT (VDC)

DESIRED RANGE (SEC1)

AS FOUND CALIBRATION TOLERANCE (SEC1)

AS LEFT FROM TO FROM TO 1.000

-75.19

-149.25

-75.19

-149.25

-10.000 9.68 10.34 9.68 10.34 1 +/- 3.0% Equivalent Linear Full Scale

HC.IC-CC.SE-0003(Q)

Hope Creek Page 58 of 61 Rev. 27 ATTACHMENT 1 18.0 (Steps 5.16.2, 5.16.5) HIGH VOLTAGE (HV) AND LOW HV INOPERATIVE TRIP PARAMETE R

DESIRE D

(VDC)

DESIRED RANGE (VDC)

AS FOUND CALIBRATION TOLERANCE (VDC)

AS LEFT FROM TO FROM TO OPER. HV

$ INOP TRIP 5.1.7.B The current OPER. HV (HV Setting) and INOP TRIP (HV INOP) settings have been recorded in the DESIRED columns of Section 18.0.

W.O.#

Job Supervisor Section 18.0 CALCULATIONS 5.1.8.A 5.1.8.B 5.1.8.C 5.1.9.A 5.1.9.B 5.1.9.C OPER. HV OPER. HV OPER. HV INOP TRIP INOP TRIP INOP TRIP x

+

x

+

0.02 (5.1.8.A)

(5.1.8.A) 0.02 (5.1.9.A)

(5.1.9.A)

= ____________ VDC

= ____________ VDC

= ____________ VDC

= ____________ VDC

= ____________ VDC

= ____________ VDC 5.16.9 Ripple Voltage mV rms (Tolerance #17 mV rms)

HC.IC-CC.SE-0003(Q)

Hope Creek Page 59 of 61 Rev. 27 ATTACHMENT 2 ADMINISTRATIVE DATA SHEET 1.0 M&TE DATA Device Name ID No.

Cal Due Date DMM DMM Electronic Counter Stopwatch 2.0 COMMENTS Order# __________________

3.0 INDIVIDUALS PERFORMING WORK Print Signature Initial Date 4.0 MAINTENANCE SUPERVISOR APPROVAL This procedure has been reviewed for completion in accordance with MA-AA-716-009.

Maintenance Supervisor / Date

HC.IC-CC.SE-0003(Q)

Hope Creek Page 60 of 61 Rev. 27 EXHIBIT 1 OPERATIONS INFORMATION SHEET (1 of 2)

Procedure

Title:

NUCLEAR INSTRUMENTATION SYSTEM - CHANNEL C SOURCE RANGE MONITOR C51-K600C Order #:

Performer Name: ________________________

Date Time NOTE Jumpers installed and modules and a relay removed during the performance of this test, will make SRM channel C INOPERABLE.

Technical Specification ACTIONs 3.3.6.b, 3.3.7.6 and/or 3.9.2 apply for this test.

Annunciators

C3 C1, SRM UPSCALE OR INOPERATIVE

C3 D1, SRM PERIOD

C3 E1, SRM DOWNSCALE

C3 E2, SRM DET REMOVAL NOT PERMITTED

C6 D3, ROD OUT MOTION BLOCK Status Lights MCP Location: SOURCE RANGE NEUTRON MONITORING MONITOR STATUS SRM C

BYPASS

DNSC

UPSC AL OR INOP

UPSC TRIP

PERIOD MCP Location: SRM C DETECTOR SELECT

RETRACT PERMIT

IN

OUT

HC.IC-CC.SE-0003(Q)

Hope Creek Page 61 of 61 Rev. 27 EXHIBIT 1 OPERATIONS INFORMATION SHEET (2 of 2)

Status Lights MCP Location: DETECTOR DRIVE (Indication)

DRIVING IN

DRIVE IN

DRIVE OUT

POWER ON

OFF Recorder VCP Location: REACTOR WATER AND NEUTRON MONITORING NEUTRON MONITORING, SRM

H1SE -1SEXR-R602A-C51, SRM (C) power indication and recording (Blue)

Computer Point

B3003, SRM CHANNEL C PERIOD

B3029, SRM CH C COUNT RATE

C013, ROD BLOCK - REFUEL MODE

C014, SRM DET NOT START-UP POS

C015, SRM UPSC ALARM

C016, SRM INOP TRIP

C039, SRM BYPASS

C048, ROD OUT BLOCK Function

Affects SRM C Rod Block Protective Functions