ML110040470

From kanterella
Jump to navigation Jump to search
Bellefonte Units 3 & 4 Cola (Final Safety Analysis Report), Rev. 3 - FSAR Chapter 01 Figure 1.1-202
ML110040470
Person / Time
Site: Bellefonte  
Issue date: 12/22/2010
From: Arent G
Tennessee Valley Authority
To:
Document Control Desk, Office of New Reactors
Spink T
References
BELLEFONTE.P02.NP, BELLEFONTE.P02.NP.3, TENNVALLEY, TENNVALLEY.SUBMISSION.6, +reviewedmmc1
Download: ML110040470 (1)


Text

SILT FENCE BRUSH SILT FENCE SWAMP SWAMP EL.594.5' EL.603.9' 630 640 645 650 655 660 665 670 675 680 685 690 695 700 705 710 715 720 750 745 740 730 630 640 625 635 640 630 625 620 615 635 615 720 715 710 705 700 695 690 685 680 675 670 665 660 655 650 645 640 630 625 620 615 610 605 600 615 610 605 600 610 620 625 625 610 615 610 610 605 600 615 600 605 610 615 610 625 620 620 615 610 605 605 610 615 620 630 625 620 610 615 610 605 600 600 595 600 605 605 600 595 595 600 600 600 605 600 595 600 605 615 610 600 600 620 605 610 615 600 610 600 595 600 600 605 605 610 615 610 615 615 620 625 640 635 630 640 635 650 655 660 615 645 650 655 660 645 650 655 660 665 610 605 640 635 630 625 620 600 615 620 625 610 605 630 635 730 725 720 715 700 695 690 705 710 680 675 640 635 645 650 655 660 665 670 685 630 600 605 610 615 620 625 600 605 610 630 635 640 645 650 655 680 685 690 660 665 670 675 695 700 705 710 715 615 610 605 600 595 595 600 620 615 610 605 600 765 760 755 750 745 740 735 730 725 720 715 710 705 695 690 685 680 675 670 665 700 800 805 795 795 790 785 780 775 770 765 760 800 775 760 765 770 605 600 605 600 605 600 600 595 600 600 600 595 605 595 600 605 605 615 610 595 595 595 595 595 NOTES:

UPON AL EAST STATE PLANE COORDINATE SYSTEM NAD 83.

2. EXISTING CONDITIONS AND TOPOGRAPHIC CONTOURS
3. CONTOUR INTERVAL IS 5 FEET.

BASED UPON THE SANBORN MAP COMPANY, INC.

1. ELEVATIONS SHOWN ARE BASED ON MEAN SEA LEVEL (MSL).

0 GRAPHIC SCALE (FEET) 1 INCH = 300 FT 300 600 900 PROJECT NO. 060319.

PHOTOGRAMMETRIC SURVEY PERFORMED ON MARCH 26,2006

4. 1000 FOOT GRID AND COORDINATE VALUES ARE BASED BUILDING LEGEND:

E626,000 E627,000 E628,000 E629,000 E632,000 E631,000 E630,000 N1,533,000 N1,534,000 N1,535,000 N1,531,000 N1,532,000 N1,530,000 EL.598.1' TOWN CREEK E625,000 GUNTERSVILLE RESERVOIR/TENNESSEE RIVER N1,532,943.23 E628,414.56 N1,532,439.80 E629,036.24 UNIT 3 UNIT 4 800' METEOROLOGICAL TOWER POND LEGEND:

TRUE NORTH AL EAST GRID (NAD 83)

FACILITY LEGEND:

1. CONTAINMENT/SHIELD BUILDING
2. TURBINE BUILDING
3. ANNEX BUILDING
4. AUXILIARY BUILDING
5. SWS COOLING TOWERS
7. RADWASTE BUILDING
10. DIESEL GENERATOR BUILDING
13. FIRE WATER/CLEARWELL STORAGE TANK
14. FIRE WATER STORAGE TANK
15. TRANSFORMER AREA
17. CONDENSATE STORAGE TANK
18. DIESEL GENERATOR OIL STORAGE TANKS
19. DEMINERALIZED WATER STORAGE TANK
20. BORIC ACID STORAGE TANK
22. TURBINE BUILDING LAYDOWN AREA
25. PASSIVE CONTAINMENT COOLING
26. DIESEL-DRIVEN FIRE PUMP/ENCLOSURE ANCILLARY WATER STORAGE TANK
99. T-PAD FOR CRANE UNIT 4 UNIT 3 9

13 4

12 12 24 11 10 13 15 7

8 18 19 6

16 3

9 21 1

14 3

20 9

2 5

17 POND C EL.600.3' POND A EL.603.7' WWRB EL.614.2' POND D EL.621.4' POND E EL.621.4' 17 625 665 670 675 725 720 715 620 625 23 22 21 14 13 12 11 10 9

8 7

6 5

15 16 17 19 18 20 4

3 2

1 POND E -

POND D -

POND C -

POND A -

YARD DRAINAGE POND CONCENTRATED CHEMICAL TREATMENT POND (LINED)

DESILTING POND ALUM SLUDGE PONDS 7

1 4

3 10 18 22 15 19 20 2

13 17 25 99 14 26 NEW UNITS 3 & 4 GENERATION 18 5

5 500 kV SWITCHYARD 161 kV SWITCHYARD TO HWY 72 MAIN SITE ACCESS ROAD 725 730 735 23 24 22 EL.633.4' 645 640 630 635 625 620 620 615 610 615 635 630 640 630 635 640 645 650 655 660 665 670 675 680 685 690 695 700 705 710 715 720 725 730 740 745 735 750 620 825 780 785 790 800 795 805 810 815 820 630 635 640 645 650 655 660 665 730 725 720 690 685 675 670 715 710 705 700 695 680 665 660 655 650 645 640 635 630 615 620 625 610 605 635 665 660 640 620 625 635 630 600 595 N1,529,000 N1,528,000 CHANNEL INTAKE BLOWDOWN VAULT BARGE UNLOADING DOCK ACCESS ROAD RAILROAD BARGE UNLOADING DOCK HOLDING POND EL.598.4' POND RIVER RIDGE 620 625 625 625 625 625 625 630 630 635 630 635 625 620 620 620 615 620 615 615 640 645 645 640 650 620 615 610 610 610 605 605 605 610 605 600 605 610 610 615 615 620 610 655 660 665 670 675 680 685 690 695 700 705 710 715 720 725 730 735 655 660 665 670 675 680 685 690 695 700 705 710 715 650 645 640 635 610 630 635 640 645 635 640 645 630 NEW PRIMARY ACCESS PORTAL NEW ADMINISTRATION BUILDING REMOVE EXIST BLDGS.

NEW MAINTENENCE BUILDING NEW MATERIAL RECEIVING &

SALLY PORT BUILDING EXISTING SIMULATOR BUILDING EXISTING UNIT 1 & 2 BUILDINGS EXISTING SITE TRAINING BLDG NEW SITE PARKING EXISTING SWITCHYARD NEW OUTAGE PARKING EXISTING COOLING TOWERS NEW SECURITY FENCE ASSY.

NEW SWITCHYARD BUILDING EXISTING STORAGE AREA NEW SECURITY ACCESS BLDG NEW CIRCULATING PUMPS NEW PSO SWITCHYARD FACILITY EXISTING SECURITY RANGE FACILITY NEW SECURITY TRAINING BUILDING NEW TECH SUPPORT CENTER (WITHIN MAINTENECE BUILDING)

NEW H2 STORAGE BUILDING NEW HAZ. WASTE STORAGE BUILDING EXISTING INTAKE PUMPING STATION 10 CONSTRUCTION 25 25 NEW TSC DIESEL GENERATOR BUILDING Site Layout BLN COL 2.1-1 Rev 1 Bellefonte Nuclear Plant, Units 3 & 4 COL Application Part 2, FSAR FIGURE 1.1-202 WWRB - WASTE WATER RETENTION BASIN BLN DEP 8.2-1