December 28, 2010 Mark A. McBurnett, Vice-President Oversight and Regulatory Affairs South Texas Project Units 3 and 4 P.O. Box 289 Wadsworth, TX 77483

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION RE: SOUTH TEXAS PROJECT NUCLEAR OPERATING COMPANY TOPICAL REPORT (TR) WCAP-17116-P REVISION 0, SUPPLEMENT 5 - APPLICATION TO THE ADVANCED BOILING WATER REACTOR (TAC NO. RG0007)

Dear Mr. McBurnett:

By letter dated September 30, 2009 (Agencywide Documents Access and Management System Accession No. ML092810245) the South Texas Project (STP) Units 3 and 4, submitted for U.S. Nuclear Regulatory Commission (NRC) staff review Topical Report WCAP-17116-P Revision 0, Supplement 5 - Application to the Advanced Boiling Water Reactor.

The NRC staff has identified that additional information is needed to continue portions of the review. The staffs request for additional information (RAI) is contained in the enclosure to this letter. The STP staff has requested a response time of 30 days.

If you have any questions or comments concerning this matter, I can be reached at 301-415-6197 or by e-mail at Tekia.Govan@nrc.gov.

Sincerely,

/RA/

Tekia V. Govan, Project Manager BWR Projects Branch Division of New Reactor Licensing Office of New Reactors Docket Nos. PROJ0772

Enclosure:

Request for Additional Information cc: See next page

ML103620337-Pkg. NRO-002 OFFICE DSRA/SRSB/TR DSRA/SRSB/TR DNRL/NGE2/PM NAME GThomas JDonoghue TGovan DATE 12/15/2010 12/15/2010 12/28/2010

COL - STP Nuclear - South Texas Mailing List (Revised 09/30/2010) cc:

Certrec Corporation M. A. McBurnett 4200 South Hulen, Suite 422 VP, Oversight/Regulatory Affairs Fort Worth, TX 76109 STP Nuclear Operating Company 4000 Avenue F, Suite A Mr. Brian Almon Bay City, TX 77414 Public Utility Commission William B. Travis Building Bill Mookhoek PO Box 13326 Licensing Supervisor 1701 North Congress Avenue STP Units 3 and 4 Austin, TX 78701-3326 Project Electric Generating Station P.O. Box 289 Ms. Michele Boyd Wadsworth, TX 77483 Legislative Director Energy Program Mr. Peter G. Nemeth Public Citizens Critical Mass Energy Crain, Caton & James, P.C.

and Environmental Program P.O. Box 289 215 Pennsylvania Avenue, SE Mail Code: N5005 Washington, DC 20003 Wadsworth, TX 77483 Mr. Ted Enos Mr. Terry Parks 4200 South Hulen Chief Inspector Suite 422 Texas Department of Licensing Ft. Worth, TX 76109 and Regulation Boiler Division Mr. Ed Halpin P.O. Box 12157 President & CEO Austin, TX 78711 STP Nulcear Operating Company P.O. Box 289 Kathy C. Perkins, RN, MBA Wadsworth, TX 77483 Assistant Commissioner Division for Regulatory Services Ms. Susan M. Jablonski Texas Department of State Health Services Office of Permitting, Remediation P.O. Box 149347 and Registration Austin, Texas 78714-9347 Texas Comm. on Env. Quality MC-122 Policy Director P.O. Box 13087 Environmental and Natural Resources Austin, TX 78711-3087 P. O. Box 12428 Austin, TX 78711-3189 Judge Matagorda County Mr. Frank M. Quinn Matagorda County Courthouse 8 Oak Avenue 1700 Seventh Street Gaithersburg, MD 20877-2705 Bay City, TX 77414 Page 1 of 4

COL - STP Nuclear - South Texas Mailing List Regional Administrator Region IV U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive Suite 400 Arlington, TX 76011-8064 Alice Hamilton Rogers, PE Inspections Unit Manager Texas Department of State Health Services P.O. Box 149347 Austin, Texas 78714-9347 Mr. Robert E. Sweeney IBEX ESI 4641 Montgomery Avenue Suite 350 Bethesda, MD 20814 Mr. Steve Winn STP Nuclear Operating Company 1301 McKinney, Suite 2300 Houston, TX 77010 Page 2 of 4

COL - STP Nuclear - South Texas Mailing List Email APH@NEI.org (Adrian Heymer) awc@nei.org (Anne W. Cottingham)

BrinkmCB@westinghouse.com (Charles Brinkman) chris.maslak@ge.com (Chris Maslak) cindyrae_52@yahoo.com cwaltman@roe.com (C. Waltman) david.lewis@pillsburylaw.com (David Lewis)

Derlinda.Bailey@chguernsey.com (Derinda Bailey) donald.woodlan@luminant.com (Donald Woodlan) dwstillwell@stpegs.com (Bill Stillwell) ed.burns@earthlink.net (Ed Burns) eliza.seedcoalition@gmail.com (Elza Brown) erg-xl@cox.net (Eddie R. Grant) gzinke@entergy.com (George Alan Zinke) jerald.head@ge.com (Jerald G. Head) jgutierrez@morganlewis.com (Jay M. Gutierrez) jim.riccio@wdc.greenpeace.org (James Riccio)

Joseph_Hegner@dom.com (Joseph Hegner) junichi_uchiyama@mnes-us.com (Junichi Uchiyama) karen@seedcoalition.org (Karen Hadden) kdrichards@stpegs.com (Kevin Richards)

KSutton@morganlewis.com (Kathryn M. Sutton) kwaugh@impact-net.org (Kenneth O. Waugh) lchandler@morganlewis.com (Lawrence J. Chandler) ldblaylock@cpsenergy.com (Larry Blaylock) louis.eichenberger@ge.com (Louis Eichenberger) mamcburnett@stpegs.com (Mark McBurnett)

Marc.Brooks@dhs.gov (Marc Brooks) maria.webb@pillsburylaw.com (Maria Webb) mark.beaumont@wsms.com (Mark Beaumont)

Mark.Crisp@chguernsey.com (Mark Crisp) matias.travieso-diaz@pillsburylaw.com (Matias Travieso-Diaz) maurerbf@westinghouse.com (Brad Maurer) media@nei.org (Scott Peterson)

MSF@nei.org (Marvin Fertel) nirsnet@nirs.org (Michael Mariotte)

Nuclaw@mindspring.com (Robert Temple) patriciaL.campbell@ge.com (Patricia L. Campbell)

Paul@beyondnuclear.org (Paul Gunter) pshastings@duke-energy.com (Peter Hastings)

RJB@NEI.org (Russell Bell) sabinski@suddenlink.net (Steve A. Bennett) sandra.sloan@areva.com (Sandra Sloan) sfrantz@morganlewis.com (Stephen P. Frantz)

Page 3 of 4

COL - STP Nuclear - South Texas Mailing List smhead@stpegs.com (Scott Head) stephan.moen@ge.com (Stephan Moen)

Tansel.Selekler@nuclear.energy.gov (Tansel Selekler) tom.miller@hq.doe.gov (Tom Miller)

Vanessa.quinn@dhs.gov (Vanessa Quinn)

Wanda.K.Marshall@dom.com (Wanda K. Marshall) wayne.marquino@ge.com (Wayne Marquino) wemookhoek@stpegs.com (Bill Mookhoek) william.maher@fpl.com (William Maher)

Page 4 of 4