ML103620025

From kanterella
Jump to navigation Jump to search
Exhibit 33 - Oceans of Opportunity - Harnessing Europes Largest Domestice Energy Resource
ML103620025
Person / Time
Site: Davis Besse 
Issue date: 06/30/2010
From: Haymes S, Heimiller D, Musial W, Schwartz M
National Renewable Energy Lab, US Dept of Energy, Office of Energy Efficiency & Renewable Energy
To:
Atomic Safety and Licensing Board Panel
SECY RAS
Shared Package
ML103620024 List:
References
License Renewal 2, RAS 19315, 50-346-LR, DE-AC36-08-GO28308, WE10.1211 NREL/TP-500-45889
Download: ML103620025 (69)


Text

Technical Report NREL/TP-500-45889 June 2010 Assessment of Offshore Wind Energy Resources for the United States Marc Schwartz, Donna Heimiller, Steve Haymes, and Walt Musial

National Renewable Energy Laboratory 1617 Cole Boulevard, Golden, Colorado 80401-3393 303-275-3000

  • www.nrel.gov NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Operated by the Alliance for Sustainable Energy, LLC Contract No. DE-AC36-08-GO28308 Technical Report NREL/TP-500-45889 June 2010 Assessment of Offshore Wind Energy Resources for the United States Marc Schwartz, Donna Heimiller, Steve Haymes, and Walt Musial Prepared under Task No. WE10.1211

NOTICE This report was prepared as an account of work sponsored by an agency of the United States government.

Neither the United States government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States government or any agency thereof.

Available electronically at http://www.osti.gov/bridge Available for a processing fee to U.S. Department of Energy and its contractors, in paper, from:

U.S. Department of Energy Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, TN 37831-0062 phone: 865.576.8401 fax: 865.576.5728 email: mailto:reports@adonis.osti.gov Available for sale to the public, in paper, from:

U.S. Department of Commerce National Technical Information Service 5285 Port Royal Road Springfield, VA 22161 phone: 800.553.6847 fax: 703.605.6900 email: orders@ntis.fedworld.gov online ordering: http://www.ntis.gov/ordering.htm Printed on paper containing at least 50% wastepaper, including 20% postconsumer waste

iii Table of Contents Executive Summary............................................................................................................ 1 Offshore Wind Resource..................................................................................................... 5 GIS Database Structure....................................................................................................... 6 Database Components..................................................................................................... 6 Wind Resource Estimates............................................................................................... 7 Bathymetry...................................................................................................................... 9 Distance from shore...................................................................................................... 11 Offshore Administrative Units...................................................................................... 12 Database Summary........................................................................................................... 13 Future Plans...................................................................................................................... 23 Acknowledgements........................................................................................................... 23 References......................................................................................................................... 23 Appendix A. Data Sources............................................................................................... 25 A1. State-to-State Boundary Data................................................................................ 25 A2. Wind Map Data..................................................................................................... 27 Appendix B. Detailed maps and tables............................................................................ 28 Appendix B. U.S. Detailed Wind Database Information by Element............................. 29

iv List of Tables Table 1. Offshore wind resource area and potential by wind speed interval and state within 50 nm of shore.......................................................................................... 3 Table 2. Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore....................................................................... 14 Table A1. State-to-State Boundary Data........................................................................ 25 Table A2. Wind Map Datasets....................................................................................... 27 Table B1. U.S. offshore wind resource by state and wind speed interval. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore............ 29 Table B1.1. U.S. offshore wind resource by state and water depth category. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore............ 32 Table B1.2. U.S. offshore wind resource by state and distance from shore. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore............ 34 Table B1.3. Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 36 Table B2. California offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 45 Table B3. Connecticut offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore............................................ 47 Table B4. Delaware offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 49 Table B5. Georgia offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 51 Table B6. Hawaii offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 53 Table B7. Illinois offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 55 Table B8. Indiana offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 57 Table B9. Louisiana offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 59 Table B10. Maine offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 61 Table B11. Maryland offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 63 Table B12. Massachusetts offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore............................................ 65 Table B13. Michigan offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 67 Table B14. Minnesota offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 69 Table B15. New Hampshire offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore............................................ 71 Table B16. New Jersey offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 73

v Table B17. New York offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 75 Table B18. North Carolina offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore............................................ 77 Table B19. Ohio offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 79 Table B20. Oregon offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 81 Table B21. Pennsylvania offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 83 Table B22. Rhode Island offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 85 Table B23. South Carolina offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore............................................ 87 Table B24. Texas offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 89 Table B25. Virginia offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 91 Table B26. Washington offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 93 Table B27. Wisconsin offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore................................................... 95 List of Figures Figure 1.

United States offshore wind resource at 90 m above the surface.

............... 10 Figure 2.

United States bathymetry distribution.

........................................................ 11 Figure 3.

Distance from United States shoreline (nm).

............................................... 12 Figure 4.

State administrative areas.

........................................................................... 13 Figure B1. United States offshore wind resource at 90 m above the surface.

............... 44 Figure B2. California detailed map

................................................................................ 46 Figure B3. Connecticut detailed map

............................................................................. 48 Figure B4. Delaware detailed map

................................................................................. 50 Figure B5. Georgia detailed map

................................................................................... 52 Figure B6. Hawaii detailed map

.................................................................................... 54 Figure B7. Illinois detailed map

..................................................................................... 56 Figure B8. Indiana detailed map

.................................................................................... 58 Figure B9. Louisiana detailed map

................................................................................ 60 Figure B10. Maine detailed map

...................................................................................... 62 Figure B11. Maryland detailed map

................................................................................ 64 Figure B12. Massachusetts detailed map

......................................................................... 66 Figure B13. Michigan detailed map

................................................................................. 68 Figure B14. Minnesota detailed tables and maps

............................................................ 70 Figure B15. New Hampshire detailed map

...................................................................... 72

vi Figure B16. New Jersey detailed map

............................................................................. 74 Figure B17. New York detailed map

............................................................................... 76 Figure B18. North Carolina detailed map

........................................................................ 78 Figure B19. Ohio detailed map

........................................................................................ 80 Figure B20. Oregon detailed map

.................................................................................... 82 Figure B21. Pennsylvania detailed map

........................................................................... 84 Figure B22. Rhode Island detailed map

........................................................................... 86 Figure B23. South Carolina detailed map

........................................................................ 88 Figure B24. Texas detailed map

...................................................................................... 90 Figure B25. Virginia detailed map

................................................................................... 92 Figure B26. Washington detailed map

............................................................................. 94 Figure B27. Wisconsin detailed map

............................................................................... 96

1 Executive Summary This report summarizes the offshore wind resource potential, based on map estimates, for the contiguous United States and Hawaii, as of May 2009. The development of this assessment has evolved over multiple stages as new regional meso-scale assessments became available, new validation data were obtained, and better modeling capabilities were implemented. It is expected that further updates to the current assessment will be made in future reports.

Offshore wind energy development promises to be a significant domestic renewable energy source, especially for coastal energy loads with limited access to interstate grid transmission. The definition of the magnitude and distribution of this resource required the development of a standard and flexible database. Developed using Geographic Information System (GIS) techniques, the database includes offshore wind resource characteristics such as wind speed, water depth, and distance from shore. It combines the resource characteristics with state administrative areas and quantifies the resource for several scenarios. In the future, the database may be expanded to include other important characteristics such as wave power density, extreme wind and wave, ocean currents, and a number of other parameters important to the design of offshore wind turbines.

The primary method used to present the offshore wind resource data are maps that categorize the resource by annual average wind speed at 90 meters (m) above the surface.

The resource maps extend from the shoreline out to 50 nautical miles (nm) offshore.

Exceptions to the 50 nm mapped distance are the Great Lakes that were mapped in their entirety for the offshore resource and Massachusetts, where the computed resource did not extend 50 nm from the edge of the Nantucket Island and Marthas Vineyard in southeastern Massachusetts. The offshore maps for some states do not extend 50 nm because of state and administrative boundaries.

There were several sources for the offshore resource maps. The oldest offshore wind resource maps were generated from data mapped as part of onshore state wind resource mapping projects. Recently, some regions have had their resource maps updated using the latest computer mapping techniques optimized for offshore modeling. For this evaluation, updated maps were available for the offshore areas of Georgia, Texas/Louisiana, northern New England (Massachusetts, New Hampshire, and Maine),

and states that border the Great Lakes. The preliminary numerical modeling was performed by AWS Truepower (AWST), of Albany, New York, under subcontract to the National Renewable Energy Laboratory (NREL), using their proprietary MesoMap system. The preliminary model estimates were validated by NREL using data from a variety of sources including ocean buoys, marine automated stations, Coast Guard stations and lighthouses, and satellite-derived 10-m wind speeds over the ocean estimated from the state of the sea as measured by microwave imaging. Final modifications to the preliminary estimates were agreed to after consultations between NREL and AWST.

AWST adjusted the model output to reflect the modifications and sent the final grids to NREL, where the data were converted into wind resource maps. The calculation of the offshore wind resource estimates for states without updated maps depended on the availability of older offshore wind maps that were completed as part of onshore wind

2 mapping projects. Where older preliminary and final offshore wind maps were available, the wind speed data from those maps were interpolated to 90 m height and, if necessary, extrapolated to the 50 nm lines. The offshore areas treated in this manner included the Atlantic coast, from Rhode Island to South Carolina, the Pacific coast, from California to Washington, and Hawaii. The states of Florida, Alabama, and Mississippi did not have any preliminary or final wind maps available. The offshore wind resource for these states is not included in this report.

Table 1 shows the offshore wind resource by available square kilometers (km2) of water and potential installed capacity in gigawatts (GW) for annual average wind speeds greater than 7.0 meters/second (m/s) at 90 m above the surface. A uniform factor of 5 megawatts/km2 was applied to calculate the potential installed capacity. The resource is presented for individual states and the country as a whole. These resource estimates have not been reduced by any environmental or water-use considerations. Detailed information by database element for each state is presented in Appendix B. The data presented in this report represents the first version of the offshore database.

3 Table 1. Offshore wind resource area and potential by wind speed interval and state within 50 nm of shore.

Wind Speed (m/s) at 90 m 7.0 - 7.5 7.5 - 8.0 8.0 - 8.5 8.5 - 9.0 9.0 - 9.5 9.5 - 10.0

>10.0 Total

>7.0 State km2 (GW) km2 (GW) km2 (GW) km2 (GW) km2 (GW) km2 (GW) km2 (GW) km2 (GW)

California 11,439 24,864 23,059 22,852 13,185 15,231 6,926 117,555 (57.2)

(124.3)

(115.3)

(114.3)

(65.9)

(76.2)

(34.6)

(587.8)

Connecticut 530 702 40 0

0 0

0 1,272 (2.7)

(3.5)

(0.2)

(0.0)

(0.0)

(0.0)

(0.0)

(6.4)

Delaware 223 724 1,062 931 0

0 0

2,940 (1.1)

(3.6)

(5.3)

(4.7)

(0.0)

(0.0)

(0.0)

(14.7)

Georgia 3,820 7,741 523 0

0 0

0 12,085 (19.1)

(38.7)

(2.6)

(0.0)

(0.0)

(0.0)

(0.0)

(60.4)

Hawaii 18,873 42,298 33,042 13,913 7,779 6,720 4,852 127,477 (94.4)

(211.5)

(165.2)

(69.6)

(38.9)

(33.6)

(24.3)

(637.4)

Illinois 92 166 3,844 90 0

0 0

4,192 (0.5)

(0.8)

(19.2)

(0.4)

(0.0)

(0.0)

(0.0)

(21.0)

Indiana 82 216 286 0

0 0

0 584 (0.4)

(1.1)

(1.4)

(0.0)

(0.0)

(0.0)

(0.0)

(2.9)

Louisiana 48,043 15,032 0

0 0

0 0

63,075 (240.2)

(75.2)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(315.4)

Maine 906 1,142 1,976 3,331 8,429 15,485 42 31,311 (4.5)

(5.7)

(9.9)

(16.7)

(42.1)

(77.4)

(0.2)

(156.6)

Maryland 2,192 1,946 1,540 5,078 0

0 0

10,756 (11.0)

(9.7)

(7.7)

(25.4)

(0.0)

(0.0)

(0.0)

(53.8)

Massachusetts 202 526 1,639 3,606 20,351 13,674 0

39,997 (1.0)

(2.6)

(8.2)

(18.0)

(101.8)

(68.4)

(0.0)

(200.0)

Michigan 4,459 18,074 31,086 34,305 8,719 0

0 96,642 (22.3)

(90.4)

(155.4)

(171.5)

(43.6)

(0.0)

(0.0)

(483.2)

Minnesota 3,102 994 0

0 0

0 0

4,096 (15.5)

(5.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(20.5)

New Hampshire 19 46 171 336 102 0

0 672 (0.1)

(0.2)

(0.9)

(1.7)

(0.5)

(0.0)

(0.0)

(3.4)

New Jersey 528 1,508 4,965 12,934 0

0 0

19,935 (2.6)

(7.5)

(24.8)

(64.7)

(0.0)

(0.0)

(0.0)

(99.7)

New York 1,105 4,358 8,324 2,876 7,453 5,322 0

29,439 (5.5)

(21.8)

(41.6)

(14.4)

(37.3)

(26.6)

(0.0)

(147.2)

North Carolina 1,847 4,098 13,655 39,875 16 0

0 59,491 (9.2)

(20.5)

(68.3)

(199.4)

(0.1)

(0.0)

(0.0)

(297.5)

Ohio 341 3,067 5,829 0

0 0

0 9,237 (1.7)

(15.3)

(29.1)

(0.0)

(0.0)

(0.0)

(0.0)

(46.2)

Oregon 388 1,493 8,644 13,925 7,394 6,065 5,986 43,894 (1.9)

(7.5)

(43.2)

(69.6)

(37.0)

(30.3)

(29.9)

(219.5)

4 Table 1 (continued) Offshore wind resource area and potential by wind speed interval and state within 50 nm of shore.

Wind Speed (m/s) at 90 m 7.0 - 7.5 7.5 - 8.0 8.0 - 8.5 8.5 - 9.0 9.0 - 9.5 9.5 - 10.0

>10.0 Total

>7.0 Pennsylvania 34 211 1,679 0

0 0

0 1,924 (0.2)

(1.1)

(8.4)

(0.0)

(0.0)

(0.0)

(0.0)

(9.6)

Rhode Island 224 126 283 671 1,461 2,360 0

5,126 (1.1)

(0.6)

(1.4)

(3.4)

(7.3)

(11.8)

(0.0)

(25.6)

South Carolina 1,457 8,202 10,384 6,007 0

0 0

26,049 (7.3)

(41.0)

(51.9)

(30.0)

(0.0)

(0.0)

(0.0)

(130.2)

Texas 2,019 24,823 16,556 12,273 0

0 0

55,671 (10.1)

(124.1)

(82.8)

(61.4)

(0.0)

(0.0)

(0.0)

(278.4)

Virginia 889 3,658 6,549 7,794 0

0 0

18,890 (4.4)

(18.3)

(32.7)

(39.0)

(0.0)

(0.0)

(0.0)

(94.4)

Washington 1,573 4,621 18,261 0

0 0

0 24,455 (7.9)

(23.1)

(91.3)

(0.0)

(0.0)

(0.0)

(0.0)

(122.3)

Wisconsin 3,715 3,405 7,761 8,417 0

0 0

23,298 (18.6)

(17.0)

(38.8)

(42.1)

(0.0)

(0.0)

(0.0)

(116.5)

Total 108,102 174,040 201,159 189,213 74,888 64,856 17,805 830,064 (540.5)

(870.2)

(1,005.8)

(946.1)

(374.4)

(324.3)

(89.0)

(4,150.3)

5 Offshore Wind Resource In May 2008, the U.S. Department of Energy (DOE) released a report detailing a deployment scenario by which the United States could achieve 20% of its electric energy supply from wind energy (U.S. Department of Energy 2008). Under this scenario, offshore wind was an essential contributor, providing 54 gigawatts of installed electric capacity to the grid. When President Obama took office in January 2009, his message clearly reinforced this challenge in a broader context of energy independence, environmental stewardship, and a strengthened economy based on clean renewable energy sources.

To achieve the deployment levels described in the 20% wind report, many technical and economic challenges must be faced. Many coastal areas in the United States have large electricity demand but have limited access to a high-quality land-based wind resource, and these areas are typically limited in their access to interstate grid transmission.

Offshore wind resources have the potential to be a significant domestic renewable energy source for coastal electricity loads. The development of a reference and validated offshore wind resource database is one of the first steps necessary to understand the magnitude of the resource and to plan the distribution and development of future offshore wind power facilities.

DOE and the National Renewable Energy Laboratory (NREL) are working to assess the full potential of the nations indigenous wind energy resources by creating a validated, national database that defines the significant characteristics used to quantify resource availability and its distribution. These elements include level of resource (annual average wind speed), water depth, distance from shore, and state administrative areas. The database will be periodically revised to reflect better wind resource estimates and to include updated information from other datasets.

This database serves as the foundation for future modifications that may include specific exclusion areas for the calculation of offshore wind resource potential. Earlier estimates of offshore wind potential in the United States made conservative assumptions to exclude large areas from development, based on their distance from shore (Musial and Butterfield 2004). In the 2004 study, all wind resources within 5 nautical miles (nm) of shore were excluded from development, two-thirds of the resource, 5 nm to 20 nm from shore, was excluded, and one-third of the resource was excluded for those areas greater than 20 nm from shore.

The paper by Musial and Butterfield detailed the rationale for exclusion factors but did not contain a detailed analysis of this subject. The basis for exclusion is a complex issue that should involve multiple stakeholders and negotiations. The development of offshore resources will be influenced by environmental and other ocean-use factors not currently included in the wind resource database.

Therefore, the current standard database quantifies the gross offshore wind resource.

Exclusions from offshore development, of which there will be many, must be done on a state or regional basis to assure that local issues are addressed properly such as was

6 attempted for areas along the Atlantic coast (Dhanju et. al 2008, Applied Technology and Management 2007).

The database provides the core information useful for the planning of resource-based offshore renewable energy development. The database incorporates the best offshore wind resource estimates with parameters that have a significant impact on offshore resource development. The main parameters include annual average wind speed, water depth (U.S. Department of Commerce's National Oceanic and Atmospheric Administration's [NOAA] Coastal Relief Model), distance from shore (shoreline delineation by NOAA), and administrative jurisdiction (U.S. Department of the Interior's Minerals Management Service [MMS]). As previously mentioned, the database was developed using Geographic Information Systems (GIS) techniques, allowing for spatial correlation of these characteristics. The offshore information presented on a state-by-state basis in this report is the first published version of the NREL offshore database.

The database will be updated periodically as new offshore wind resource studies are completed and/or new information layers become available that directly impact offshore development.

GIS Database Structure A GIS database was chosen to house the offshore resource data because the datasets have a significant spatial component. All of the component datasets are spatially referenced to the same spatial base allowing rapid indexing of the different datasets to each other. A database user may compare information from different datasets in the same geographic location. The GIS database also allows portions of a dataset to be quickly updated as new information becomes available. The database is sufficiently flexible to allow new elements such as environmental exclusion areas and shipping lanes/navigation zones, for example, to be included in future versions. The horizontal resolution of the database grid cells is 100 m by 100 m. The database extends out from the shoreline to 50 nm and includes major bays and inlets. Exceptions to the 50 nm mapped distance are the Great Lakes, where the entire lakes were mapped for the offshore resource, and Massachusetts, where the computed resource did not extend 50 nm from the edge of Nantucket Island and Marthas Vineyard in southeastern Massachusetts.

For ease of use and maintenance, the database has been divided into four regions initially:

1) Pacific coast (California, Oregon and Washington); 2) Atlantic coast (Maine, New Hampshire, Massachusetts, Rhode Island, Connecticut, New York, New Jersey, Delaware, Maryland, Virginia, North Carolina, South Carolina, Georgia, and Florida);

Lakes (New York, Pennsylvania, Ohio, Michigan, Indiana, Illinois, Wisconsin, and Minnesota). Hawaii, Alaska, and U.S. territories are handled separately.

3) Gulf of Mexico (Florida, Alabama, Mississippi, Louisiana, and Texas); and 4) Great Database Components The database contains wind resource information in two types of fields. The first field is wind power class introduced in the Wind Energy Resource Atlas of the United States (Elliott et. al. 1987) at a 50 m height above the surface. The second field is the annual

7 average wind speed at 90 m above the surface, the approximate hub-height of many current-day offshore wind turbines. This report presents information from this second field in the maps, figures, and tables in the body and appendices. The annual speeds in the database are binned in 0.25 meters per second (m/s) intervals, with the speed in the database defined as the midpoint of the interval. For example, a grid cell with an annual speed between 7.0 and 7.25 m/s receives a database value of 7.125 m/s. The speeds (and power classes) are binned because the elements in the database are required to be represented in discrete intervals. The database indexes wind resource potential by water depth at intervals of 10 m, distance from shore out to 50 nm in increments of 1 nm, and the best available offshore state and federal administrative boundaries, provided primarily by the MMS. Indexing allows the database to be summarized in different ways using these attributes (e.g. resource within 0-5 nm or 0-3 nm of shoreline).

Wind Resource Estimates Annual average wind speeds are closely related to the available energy at a particular location and are categorized in the database by their value at a height of 90 m above the surface. The offshore wind resources of the United States were first estimated by NREL in 2003 (Musial and Butterfield 2004). Since then, updated offshore wind mapping projects (e.g. Elliott and Schwartz 2006) are gradually being completed. The updated maps provide a better estimate of the offshore wind resource than was previously available. At present, updated maps are available for the offshore areas of Georgia, Texas/Louisiana, northern New England (Massachusetts, New Hampshire, and Maine) and the states bordering the Great Lakes.

The updated wind resource maps were produced using a physics-based numerical computer model that provided preliminary estimates of the annual average wind resource.

The modeling was developed by AWS Truepower (AWST) of Albany, New York, under subcontract to NREL, using their proprietary MesoMap system. The horizontal resolution of the model output is 200 m. The preliminary model estimates were validated by NREL using data from a variety of sources including ocean buoys, marine automated stations, Coast Guard stations and lighthouses, and satellite-derived 10 m wind speeds over the ocean estimated from the state of the sea as measured by microwave imaging.

The wind measurements from the stations or grid points (in the case of satellite measurements) were extrapolated to 50 m above the surface and compared to the model estimates at the same height using sheer exponents from the Power Law Equation (Elliott et. al. 1987). The results of the validation model-measurement comparison were assembled into a spreadsheet and reviewed by AWST. In addition, NREL also produced qualitative comments on the validation results including recommended modifications to the preliminary resource estimates. Final modifications were agreed to after consultations between NREL and AWST. AWST adjusted the model output to reflect the modifications. There were not sufficient tall tower data to perform a high-quality validation at 90 m. Therefore, the modifications to the preliminary 90 m wind speed model output were based on the 50 m validation results. This adds some uncertainty to the final potential estimates, but should not significantly affect the scope of the offshore potential. NREL converted the final data into wind resource maps. The wind resource

8 data were re-sampled from 200 m to 100 m horizontal resolution for inclusion in the database.

Calculations of the offshore wind resource estimates for states with older offshore wind maps (originally completed as part of an onshore wind mapping project) were done in two ways. For eight states, data from an older non-validated preliminary (model estimate) offshore wind map and a validated older final map were combined to calculate the offshore resource. Preliminary non-validated maps were used because: 1) older final wind maps extended only 5-10 nm offshore, while the preliminary maps extended further off the coast, thus reducing the area extrapolated to 50 nm; and 2) using the preliminary data resulted in more realistic offshore wind speed gradients than the gradients produced by extrapolating the older final map values from their seaward edges out to an additional 40-45 nm to the 50 nm line. Older final maps for five states (including the Atlantic coast of New York) extended either to the 50 nm line or the state boundary. In these cases, the data from the older final map was used to calculate the offshore potential without extrapolation. The complete listing of the older and updated offshore maps used for this project is in Appendix A. The states of Florida, Alabama, and Mississippi did not have any preliminary or final wind maps available. The lack of tall tower wind measurement data and offshore wind maps for this region made an estimate of the 90 m wind speeds problematic. Therefore, the offshore wind resource for these states was not included in this report. They will be included in the database once updated offshore maps for these states are complete.

The 90 m average wind speeds were calculated in several ways depending on the available height of the older preliminary and final map data. The states along the Atlantic coast from Rhode Island to North Carolina, and the state of Hawaii had offshore map wind speed values at 70 m and 100 m above the surface. For these states, the 90 m wind speed was calculated by a linear interpolation between the 70 m and 100 m wind speeds.

The states of South Carolina, Washington, and Oregon had only 50 m map wind speeds available. The 90 m wind speeds for these states were calculated using a power law wind speed shear exponent (Elliott et. al. 1987) of 0.11. This exponent value was chosen based on the validation experience with the updated offshore wind maps and because other analyses of offshore wind resources indicate that the shear exponent is most often in the range from 0.08 to 0.14 for the offshore regions of the United States. The wind speeds at 90 m were about 6.5% higher than the 50 m wind speeds using the 0.11 shear exponent.

Wind speed maps at 50 m and 70 m were available for California. The 90 m speed off the California coast was calculated assuming the speed shear exponent calculated between the 50 m and 70 m levels was also valid for the wind speeds between 70 m and 90 m.

For eight states (the Pacific coast and the Atlantic Coast from New Jersey to North Carolina), where both the older preliminary and final maps were used to estimate the wind resource, a blend of the calculated 90 m speeds from the preliminary and final maps was used to extrapolate the offshore potential to 50 nm. Speed values from the final maps were used to calculate the wind resource from close to shore out to the boundary between the final and preliminary maps. The speed at this boundary was calculated as a blend of the two final and preliminary map values. The preliminary map wind speeds were used

9 from this boundary to the seaward edge of the preliminary map data. The wind speed values at the seaward edge of the preliminary map were held constant and expanded to the 50 nm line. The extrapolation from the edge of the preliminary map is a source of uncertainty in the final results for these eight states.

Horizontal discontinuities (seams) in the wind resource are present at several state boundaries. The discontinuities result from offshore data that is based on different versions of the numerical model used for the different onshore mapping projects and the way the extrapolation software interprets the data on either side of the seam. The most prominent seam appears near the border of Oregon and California. The resulting wind speed gradients in that region are not realistic. Other noticeable seams are located on the borders of New York and New Jersey and North Carolina and South Carolina. These seams in the maps and data interpretations further demonstrate the need to complete the updated offshore wind resource maps along the Atlantic and Pacific coasts.

Individual state and regional datasets were combined to form a composite image, based on 2009 map estimates, of the national offshore wind resource (Figure 1). The datasets are listed in Appendix A. The wind resource information is categorized by wind speed.

However, for this initial report only areas with annual average wind speeds of 7.0 m/s and greater are included in the wind potential estimates. Economic factors make development of areas with less than 7.0 m/s average wind speeds unlikely. This delineation may be adjusted in future versions of the database as warranted.

Examinations of the offshore wind resource distribution show an abundant wind resource pool, with wind resources greater than 7.0 m/s, located in many offshore areas of the country.

Bathymetry The depth of the water affects the type of technology used to develop a given offshore wind resource project (Musial 2007). Current offshore wind turbine technology uses monopoles and gravity foundations in shallow water (0 m to 30 m). In transitional depths (30 m to 60 m), tripods, jackets and truss-type towers will be used. Deep water (> 60 m depth) may require floating structures instead of fixed bottom foundations, but this technology is currently in an early stage of development.

The bathymetry data used in the database has been categorized into 10 m water depth intervals, with depth calculated relative to the mean water surface height (Figure 2). The majority of the data was acquired from the U.S. Department of Commerce National Oceanic and Atmospheric Administration (NOAA) Coastal Relief Model. This dataset has a spatial resolution of 90 m. However, Lake Superior and some coastal areas further from shore were not included in the NOAA dataset. For those areas, bathymetry was interpolated from a spatially coarser global NOAA bathymetry dataset.

The East coast and the Gulf of Mexico have extensive areas of shallow water relatively far from shore. On the West coast, the continental shelf descends rapidly into the deep water category. The water depth also increases rapidly away from shore around Hawaii.

In the Great Lakes region, Lake Erie and portions of Lake Ontario can be characterized as

10 shallow; the other lakes are primarily deep water, with narrow bands of shallow and transitional water near the shore.

Figure 1. United States offshore wind resource at 90 m above the surface.

11 Figure 2. United States bathymetry distribution.

Distance From Shore The distance a wind project is from shore determines a projects visibility from shore, and whether it is located in state or federal jurisdiction. Distance affects the potential cost of development through considerations such as the length of underwater cable needed to connect the offshore wind project to land-based electricity distribution facilities. In addition, coastline definition is complex because it is derived from a series of baseline points representing the mean lower low water line in direct contact with the open ocean (Thormahlen 1999). Some of these points can be seaward of the contiguous shoreline and change over time due to accretion and erosion of the shoreline. The MMS computed geographic lines from these points determining the boundary of state/federal offshore jurisdictions required by the Submerged Lands Act (SLA) (Thormahlen 1999).

In Hawaii, the state/federal boundary was determined by NOAA. The database uses nm in its distance calculations. Federal jurisdiction begins 3 nm from the MMS baseline, except for Texas and the Gulf coast of Florida, where it begins at 9 nm. For the Atlantic coast, Pacific coast, and Gulf of Mexico distances are measured from the SLA line towards or away from shore, extending seaward a maximum of 50 nm. For the Great Lakes and Hawaii, distances were measured from the shoreline (Figure 3).

12 Figure 3. Distance from United States shoreline (nm).

Offshore Administrative Units The determination of offshore jurisdiction encompasses complex legal agreements between individual states, legal agreements between the individual states and the federal government, and treaties between the United States and adjacent countries. Some of these boundaries are currently unresolved (New Jersey v. Delaware, Supreme Court Decision No. 134 Original, October Term 2007, and Thormahlen 1999). The state/federal offshore boundary is determined by the SLA and individual Supreme Court decisions for Texas and Florida (Thormahlen 1999). Seaward of the SLA, the MMS has proposed state boundaries that extend from the SLA line to the limit of the United States Outer Continental Shelf (OCS) based on the United Nations Convention on the Law of the Sea (Federal Register). Landward of the SLA line, state boundaries are based on legal agreements dating back to the Colonial period. A national dataset is still under development by the MMS and NOAA. For this report, NREL constructed an offshore administrative boundaries dataset from the MMS SLA, OCS, and OCS Administrative Boundaries, and individual state and local government administrative boundary datasets (Figure 4, by color). Where there was no available state data landward of the SLA, NREL constructed lines from the SLA to the shoreline. The list of data sources is provided in Appendix A.

13 Figure 4. State administrative areas.

Database Summary The offshore wind resource database contains the wind resource, water depth, distance from shore, and administrative unit for each 100 m by 100 m area out to a distance of 50 nm. The data consist of the gross wind energy resources without considering any exclusion areas. In other words, these tables do not exclude the wind resource as a function of distance from shore (Musial and Butterfield 2004), nor do they exclude the available resource due to environmental and other ocean-use factors. These data are the best available offshore wind resource data at present. The uncertainty of these resource estimates will significantly decrease as additional updated maps are completed.

Table 2 shows the gross wind resource at 90 m by state. The available square kilometers (km2) of water and potential installed capacity in gigawatts (GW) is presented by wind speed interval (for annual wind speeds 7.0 m/s and higher), water depth, and distance from shore. A uniform factor of 5 megawatts/km2 was applied to calculate the potential installed capacity. Detailed information by database element for each state is presented in Appendix B.

14 Table 2. Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

California 7.0-7.5 266.2 236.2 257.4 100.9 456.8 4,554.0 7.7 22.9 5,536.8 11,438.9 (1.3)

(1.2)

(1.3)

(0.5)

(2.3)

(22.8)

(0.0)

(0.1)

(27.7)

(57.2) 7.5-8.0 239.1 256.9 189.6 78.8 595.7 3,854.6 0.0 32.9 19,616.1 24,863.7 (1.2)

(1.3)

(0.9)

(0.4)

(3.0)

(19.3)

(0.0)

(0.2)

(98.1)

(124.3) 8.0-8.5 125.2 178.2 281.8 7.1 105.8 4,539.1 0.0 0.0 17,822.2 23,059.3 (0.6)

(0.9)

(1.4)

(0.0)

(0.5)

(22.7)

(0.0)

(0.0)

(89.1)

(115.3) 8.5-9.0 43.2 141.7 176.4 0.6 38.0 4,559.8 0.0 0.0 17,892.0 22,851.6 (0.2)

(0.7)

(0.9)

(0.0)

(0.2)

(22.8)

(0.0)

(0.0)

(89.5)

(114.3) 9.0-9.5 2.1 18.8 14.9 0.0 0.9 988.0 0.0 0.0 12,160.2 13,184.8 (0.0)

(0.1)

(0.1)

(0.0)

(0.0)

(4.9)

(0.0)

(0.0)

(60.8)

(65.9) 9.5-10.0 0.0 6.0 13.9 0.0 0.0 656.1 0.0 0.0 14,554.8 15,230.7 (0.0)

(0.0)

(0.1)

(0.0)

(0.0)

(3.3)

(0.0)

(0.0)

(72.8)

(76.2)

>10.0 0.0 0.0 0.1 0.0 0.0 288.1 0.0 0.0 6,637.6 6,925.8 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.4)

(0.0)

(0.0)

(33.2)

(34.6)

Connecticut 7.0-7.5 500.1 30.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 530.4 (2.5)

(0.2)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(2.7) 7.5-8.0 617.3 83.0 1.2 0.0 0.0 0.0 0.0 0.0 0.0 701.6 (3.1)

(0.4)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(3.5) 8.0-8.5 34.6 5.0 0.4 0.0 0.0 0.0 0.0 0.0 0.0 40.1 (0.2)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.2)

Delaware 7.0-7.5 223.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 223.2 (1.1)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.1) 7.5-8.0 716.5 2.0 0.0 5.2 0.0 0.0 0.0 0.0 0.0 723.7 (3.6)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(3.6) 8.0-8.5 135.4 10.5 0.0 658.0 8.6 0.0 240.4 8.9 0.0 1,061.9 (0.7)

(0.1)

(0.0)

(3.3)

(0.0)

(0.0)

(1.2)

(0.0)

(0.0)

(5.3) 8.5-9.0 0.0 0.0 0.0 0.0 0.0 0.0 254.0 677.4 0.0 931.4 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.3)

(3.4)

(0.0)

(4.7)

15 Table 2 (continued). Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

Georgia 7.0-7.5 547.5 0.0 0.0 2,162.3 0.0 0.0 1,110.6 0.0 0.0 3,820.4 (2.7)

(0.0)

(0.0)

(10.8)

(0.0)

(0.0)

(5.6)

(0.0)

(0.0)

(19.1) 7.5-8.0 85.2 0.0 0.0 529.6 0.0 0.0 5,204.3 1,922.1 0.0 7,741.2 (0.4)

(0.0)

(0.0)

(2.6)

(0.0)

(0.0)

(26.0)

(9.6)

(0.0)

(38.7) 8.0-8.5 0.0 0.0 0.0 0.0 0.0 0.0 3.9 519.5 0.0 523.4 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(2.6)

(0.0)

(2.6)

Hawaii 7.0-7.5 111.5 97.2 2,631.5 0.0 42.6 2,213.3 44.4 116.8 13,615.3 18,872.6 (0.6)

(0.5)

(13.2)

(0.0)

(0.2)

(11.1)

(0.2)

(0.6)

(68.1)

(94.4) 7.5-8.0 65.5 107.0 2,404.0 0.0 145.0 5,051.6 6.9 250.7 34,267.6 42,298.3 (0.3)

(0.5)

(12.0)

(0.0)

(0.7)

(25.3)

(0.0)

(1.3)

(171.3)

(211.5) 8.0-8.5 92.2 114.8 2,364.3 0.0 15.0 4,755.7 0.2 0.3 25,699.5 33,042.0 (0.5)

(0.6)

(11.8)

(0.0)

(0.1)

(23.8)

(0.0)

(0.0)

(128.5)

(165.2) 8.5-9.0 65.6 67.0 2,105.2 0.0 0.0 2,625.5 0.0 0.0 9,050.0 13,913.3 (0.3)

(0.3)

(10.5)

(0.0)

(0.0)

(13.1)

(0.0)

(0.0)

(45.3)

(69.6) 9.0-9.5 25.7 39.0 995.6 0.0 0.0 1,853.0 0.0 0.0 4,865.5 7,778.8 (0.1)

(0.2)

(5.0)

(0.0)

(0.0)

(9.3)

(0.0)

(0.0)

(24.3)

(38.9) 9.5-10.0 22.0 39.8 666.0 0.0 0.0 1,064.9 0.0 0.0 4,926.8 6,719.6 (0.1)

(0.2)

(3.3)

(0.0)

(0.0)

(5.3)

(0.0)

(0.0)

(24.6)

(33.6)

>10.0 26.3 70.5 1,344.0 0.0 0.0 2,027.6 0.0 0.0 1,383.5 4,852.0 (0.1)

(0.4)

(6.7)

(0.0)

(0.0)

(10.1)

(0.0)

(0.0)

(6.9)

(24.3)

Illinois 7.0-7.5 91.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 91.6 (0.5)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.5) 7.5-8.0 164.6 0.0 0.0 0.0 0.1 0.0 0.0 1.3 0.0 166.0 (823.1)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.8) 8.0-8.5 244.2 1.0 0.0 830.4 512.2 140.7 7.1 426.1 1,682.8 3,844.5 (1.2)

(0.0)

(0.0)

(4.2)

(2.6)

(0.7)

(0.0)

(2.1)

(8.4)

(19.2) 8.5-9.0 0.0 0.0 0.0 13.4 76.6 0.0 0.0 0.0 0.0 89.9 (0.0)

(0.0)

(0.0)

(0.1)

(0.4)

(0.0)

(0.0)

(0.0)

(0.0)

(0.4)

16 Table 2 (continued). Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

Indiana 7.0-7.5 82.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 82.1 (0.4)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.4) 7.5-8.0 153.8 0.0 0.0 62.6 0.0 0.0 0.0 0.0 0.0 216.3 (0.8)

(0.0)

(0.0)

(0.3)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.1) 8.0-8.5 101.5 0.0 0.0 184.0 0.0 0.0 0.0 0.0 0.0 285.5 (0.5)

(0.0)

(0.0)

(0.9)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.4)

Louisiana 7.0-7.5 7,759.6 28.6 0.0 7,825.2 643.4 1,460.4 11,163.9 5,479.1 13,682.4 48,042.7 (38.8)

(0.1)

(0.0)

(39.1)

(3.2)

(7.3)

(55.8)

(27.4)

(68.4)

(240.2) 7.5-8.0 155.3 0.0 0.0 1,624.5 0.0 0.0 8,169.9 2,228.7 2,854.1 15,032.5 (0.8)

(0.0)

(0.0)

(8.1)

(0.0)

(0.0)

(40.8)

(11.1)

(14.3)

(75.2)

Maine 7.0-7.5 787.0 91.2 11.9 7.8 4.8 3.5 0.0 0.0 0.0 906.2 (3.9)

(0.5)

(0.1)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(4.5) 7.5-8.0 797.2 285.4 19.4 6.7 19.6 14.1 0.0 0.0 0.0 1,142.3 (4.0)

(1.4)

(0.1)

(0.0)

(0.1)

(0.1)

(0.0)

(0.0)

(0.0)

(5.7) 8.0-8.5 777.0 440.8 74.2 63.4 385.6 234.5 0.0 0.0 0.0 1,975.6 (3.9)

(2.2)

(0.4)

(0.3)

(1.9)

(1.2)

(0.0)

(0.0)

(0.0)

(9.9) 8.5-9.0 513.4 614.0 157.6 18.2 219.1 1,401.9 0.0 0.0 406.8 3,331.1 (2.6)

(3.1)

(0.8)

(0.1)

(1.1)

(7.0)

(0.0)

(0.0)

(2.0)

(16.7) 9.0-9.5 142.2 390.0 309.2 25.9 469.0 3,504.1 0.0 57.8 3,530.9 8,429.2 (0.7)

(2.0)

(1.5)

(0.1)

(2.3)

(17.5)

(0.0)

(0.3)

(17.7)

(42.1) 9.5-10.0 5.5 24.9 42.3 1.0 38.3 1,459.8 0.0 7.4 13,905.6 15,484.7 (0.0)

(0.1)

(0.2)

(0.0)

(0.2)

(7.3)

(0.0)

(0.0)

(69.5)

(77.4)

>10.0 0.0 0.0 0.0 0.0 0.0 41.6 0.0 0.0 0.0 41.6 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.2)

(0.0)

(0.0)

(0.0)

(0.2)

Maryland 7.0-7.5 2,175.4 16.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2,192.0 (10.9)

(0.1)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(11.0) 7.5-8.0 1,922.5 14.0 0.0 9.9 0.0 0.0 0.0 0.0 0.0 1,946.4 (9.6)

(0.1)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(9.7)

17 Table 2 (continued). Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

Maryland 8.0-8.5 163.3 0.0 0.0 924.0 0.0 0.0 435.4 17.2 0.0 1,539.9 (cont.)

(0.8)

(0.0)

(0.0)

(4.6)

(0.0)

(0.0)

(2.2)

(0.1)

(0.0)

(7.7) 8.5-9.0 0.0 0.0 0.0 0.0 0.0 0.0 531.3 3,210.7 1,336.1 5,078.1 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(2.7)

(16.1)

(6.7)

(25.4)

Massachusetts 7.0-7.5 201.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 201.6 (1.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.0) 7.5-8.0 521.4 4.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 526.1 (2.6)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(2.6) 8.0-8.5 927.4 327.3 28.6 78.2 152.0 125.5 0.0 0.0 0.0 1,639.1 (4.6)

(1.6)

(0.1)

(0.4)

(0.8)

(0.6)

(0.0)

(0.0)

(0.0)

(8.2) 8.5-9.0 1,508.2 378.1 12.6 315.0 354.5 812.2 11.4 23.5 190.4 3,606.0 (7.5)

(1.9)

(0.1)

(1.6)

(1.8)

(4.1)

(0.1)

(0.1)

(1.0)

(18.0) 9.0-9.5 1,137.0 322.6 20.0 2,696.9 1,418.6 1,006.5 1,689.9 5,051.8 7,007.4 20,350.7 (5.7)

(1.6)

(0.1)

(13.5)

(7.1)

(5.0)

(8.4)

(25.3)

(35.0)

(101.8) 9.5-10.0 2.0 0.0 0.0 8.6 119.2 0.0 472.1 3,459.5 9,612.5 13,674.0 (0.0)

(0.0)

(0.0)

(0.0)

(0.6)

(0.0)

(2.4)

(17.3)

(48.1)

(68.4)

Michigan 7.0-7.5 3,411.4 330.6 243.7 142.6 49.8 268.0 1.2 0.0 12.1 4,459.3 (17.1)

(1.7)

(1.2)

(0.7)

(0.2)

(1.3)

(0.0)

(0.0)

(0.1)

(22.3) 7.5-8.0 4,632.7 1,258.2 635.3 3,069.0 2,916.4 2,991.0 14.2 108.5 2,448.4 18,073.7 (23.2)

(6.3)

(3.2)

(15.3)

(14.6)

(15.0)

(0.1)

(0.5)

(12.2)

(90.4) 8.0-8.5 2,588.1 1,253.3 769.0 2,770.6 5,889.7 9,411.9 30.9 876.1 7,496.4 31,085.9 (12.9)

(6.3)

(3.8)

(13.9)

(29.4)

(47.1)

(0.2)

(4.4)

(37.5)

(155.4) 8.5-9.0 138.7 156.2 396.5 145.1 550.6 8,580.8 118.5 1,383.9 22,834.5 34,304.7 (0.7)

(0.8)

(2.0)

(0.7)

(2.8)

(42.9)

(0.6)

(6.9)

(114.2)

(171.5) 9.0-9.5 0.0 0.0 0.0 0.0 0.0 69.9 114.6 249.6 8,284.5 8,718.7 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.3)

(0.6)

(1.2)

(41.4)

(43.6)

18 Table 2 (continued). Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

Minnesota 7.0-7.5 5.1 43.6 272.6 0.0 31.5 1,718.1 0.0 0.0 1,031.1 3,101.9 (0.0)

(0.2)

(1.4)

(0.0)

(0.2)

(8.6)

(0.0)

(0.0)

(5.2)

(15.5) 7.5-8.0 0.0 0.1 12.7 0.0 0.0 60.8 0.0 0.0 920.7 994.3 (0.0)

(0.0)

(0.1)

(0.0)

(0.0)

(0.3)

(0.0)

(0.0)

(4.6)

(5.0)

New Hampshire 7.0-7.5 18.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 18.6 (0.1)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.1) 7.5-8.0 45.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 45.8 (0.2)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.2) 8.0-8.5 44.6 29.7 0.0 6.9 75.5 14.0 0.0 0.0 0.0 170.6 (0.2)

(0.1)

(0.0)

(0.0)

(0.4)

(0.1)

(0.0)

(0.0)

(0.0)

(0.9) 8.5-9.0 0.0 8.0 7.2 0.0 12.4 255.7 0.0 10.1 42.2 335.7 (0.0)

(0.0)

(0.0)

(0.0)

(0.1)

(1.3)

(0.0)

(0.1)

(0.2)

(1.7) 9.0-9.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 35.2 66.4 101.6 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.2)

(0.3)

(0.5)

New Jersey 7.0-7.5 520.2 0.0 0.0 8.2 0.0 0.0 0.0 0.0 0.0 528.5 (2.6)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(2.6) 7.5-8.0 960.4 0.0 0.0 518.6 27.9 0.7 0.0 0.0 0.0 1,507.6 (4.8)

(0.0)

(0.0)

(2.6)

(0.1)

(0.0)

(0.0)

(0.0)

(0.0)

(7.5) 8.0-8.5 776.9 0.0 0.0 2,764.8 127.1 3.2 899.4 372.4 21.6 4,965.4 (3.9)

(0.0)

(0.0)

(13.8)

(0.6)

(0.0)

(4.5)

(1.9)

(0.1)

(24.8) 8.5-9.0 13.1 0.0 0.0 214.7 0.0 0.0 2,019.5 10,382.4 303.8 12,933.5 (0.1)

(0.0)

(0.0)

(1.1)

(0.0)

(0.0)

(10.1)

(51.9)

(1.5)

(64.7)

New York 7.0-7.5 1,047.9 54.2 0.0 2.8 0.0 0.0 0.0 0.0 0.0 1,104.8 (5.2)

(0.3)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(5.5) 7.5-8.0 1,983.1 354.7 11.6 472.7 609.0 866.8 0.0 0.0 59.9 4,357.8 (9.9)

(1.8)

(0.1)

(2.4)

(3.0)

(4.3)

(0.0)

(0.0)

(0.3)

(21.8) 8.0-8.5 1,329.3 602.9 196.5 375.6 535.7 3,122.0 42.2 12.6 2,107.4 8,324.1 (6.6)

(3.0)

(1.0)

(1.9)

(2.7)

(15.6)

(0.2)

(0.1)

(10.5)

(41.6)

19 Table 2 (continued). Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

New York 8.5-9.0 535.1 110.6 0.6 1,042.6 93.8 0.0 261.5 727.8 104.5 2,876.4 (cont.)

(2.7)

(0.6)

(0.0)

(5.2)

(0.5)

(0.0)

(1.3)

(3.6)

(0.5)

(14.4) 9.0-9.5 5.4 0.0 0.0 391.9 1,407.6 0.0 6.4 4,926.1 716.0 7,453.3 (0.0)

(0.0)

(0.0)

(2.0)

(7.0)

(0.0)

(0.0)

(24.6)

(3.6)

(37.3) 9.5-10.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1,817.6 3,504.8 5,322.4 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(9.1)

(17.5)

(26.6)

North Carolina 7.0-7.5 1,847.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1,847.4 (9.2)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(9.2) 7.5-8.0 3,002.1 0.0 0.0 1,096.1 0.0 0.0 0.0 0.0 0.0 4,098.3 (15.0)

(0.0)

(0.0)

(5.5)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(20.5) 8.0-8.5 3,920.0 0.1 0.1 4,653.8 0.0 0.0 4,034.9 746.5 299.2 13,654.7 (19.6)

(0.0)

(0.0)

(23.3)

(0.0)

(0.0)

(20.2)

(3.7)

(1.5)

(68.3) 8.5-9.0 105.0 0.0 0.0 2,964.1 261.4 8.9 6,382.4 14,519.6 15,633.3 39,874.8 (0.5)

(0.0)

(0.0)

(14.8)

(1.3)

(0.0)

(31.9)

(72.6)

(78.2)

(199.4) 9.0-9.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 16.0 0.0 16.0 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.1)

(0.0)

(0.1)

Ohio 7.0-7.5 341.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 341.0 (1.7)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.7) 7.5-8.0 1,106.8 0.0 0.0 1,959.8 0.0 0.0 0.0 0.0 0.0 3,066.7 (5.5)

(0.0)

(0.0)

(9.8)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(15.3) 8.0-8.5 565.2 0.0 0.0 2,193.1 0.0 0.0 3,071.2 0.0 0.0 5,829.5 (2.8)

(0.0)

(0.0)

(11.0)

(0.0)

(0.0)

(15.4)

(0.0)

(0.0)

(29.1)

Oregon 7.0-7.5 355.8 20.6 0.0 0.9 9.2 1.2 0.0 0.0 0.0 387.6 (1.8)

(0.1)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.9) 7.5-8.0 523.0 319.2 37.6 46.5 231.8 335.0 0.0 0.0 0.0 1,493.0 (2.6)

(1.6)

(0.2)

(0.2)

(1.2)

(1.7)

(0.0)

(0.0)

(0.0)

(7.5) 8.0-8.5 198.3 277.0 6.6 19.0 595.7 2,558.5 0.0 0.0 4,989.5 8,644.4 (1.0)

(1.4)

(0.0)

(0.1)

(3.0)

(12.8)

(0.0)

(0.0)

(24.9)

(43.2)

20 Table 2 (continued). Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

Oregon 8.5-9.0 64.1 98.8 0.6 0.0 108.0 1,967.2 0.0 45.6 11,640.3 13,924.6 (cont.)

(0.3)

(0.5)

(0.0)

(0.0)

(0.5)

(9.8)

(0.0)

(0.2)

(58.2)

(69.6) 9.0-9.5 64.1 55.4 38.6 0.0 32.6 614.9 0.0 0.0 6,588.2 7,393.7 (0.3)

(0.3)

(0.2)

(0.0)

(0.2)

(3.1)

(0.0)

(0.0)

(32.9)

(37.0) 9.5-10.0 47.3 80.4 14.6 0.0 33.8 634.6 0.0 0.0 5,254.6 6,065.3 (0.2)

(0.4)

(0.1)

(0.0)

(0.2)

(3.2)

(0.0)

(0.0)

(26.3)

(30.3)

>10.0 0.2 19.4 33.3 0.0 18.2 1,368.5 0.0 0.0 4,546.0 5,985.5 (0.0)

(0.1)

(0.2)

(0.0)

(0.1)

(6.8)

(0.0)

(0.0)

(22.7)

(29.9)

Pennsylvania 7.0-7.5 34.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 34.2 (0.2)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.2) 7.5-8.0 113.4 0.0 0.0 53.2 44.2 0.0 0.0 0.0 0.0 210.8 (0.6)

(0.0)

(0.0)

(0.3)

(0.2)

(0.0)

(0.0)

(0.0)

(0.0)

(1.1) 8.0-8.5 276.2 0.9 0.0 750.8 358.1 0.0 222.9 70.2 0.0 1,679.1 (1.4)

(0.0)

(0.0)

(3.8)

(1.8)

(0.0)

(1.1)

(0.4)

(0.0)

(8.4)

Rhode Island 7.0-7.5 216.3 8.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 224.3 (1.1)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(1.1) 7.5-8.0 123.2 2.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 126.0 (0.6)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.6) 8.0-8.5 139.9 39.8 0.0 34.5 69.2 0.0 0.0 0.0 0.0 283.5 (0.7)

(0.2)

(0.0)

(0.2)

(0.3)

(0.0)

(0.0)

(0.0)

(0.0)

(1.4) 8.5-9.0 120.3 93.0 0.0 183.6 274.2 0.0 0.0 0.0 0.0 671.2 (0.6)

(0.5)

(0.0)

(0.9)

(1.4)

(0.0)

(0.0)

(0.0)

(0.0)

(3.4) 9.0-9.5 53.7 17.6 0.0 176.0 782.7 0.0 0.0 430.2 1.3 1,461.5 (0.3)

(0.1)

(0.0)

(0.9)

(3.9)

(0.0)

(0.0)

(2.2)

(0.0)

(7.3) 9.5-10.0 0.0 0.0 0.0 0.0 5.8 0.0 0.0 967.2 1,386.8 2,359.8 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(4.8)

(6.9)

(11.8)

21 Table 2 (continued). Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

South Carolina 7.0-7.5 848.2 0.0 0.0 608.4 0.0 0.0 0.0 0.0 0.0 1,456.5 (4.2)

(0.0)

(0.0)

(3.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(7.3) 7.5-8.0 593.5 0.0 0.0 3,053.9 0.0 0.0 4,267.6 287.0 0.0 8,202.1 (3.0)

(0.0)

(0.0)

(15.3)

(0.0)

(0.0)

(21.3)

(1.4)

(0.0)

(41.0) 8.0-8.5 22.9 0.0 0.0 1,609.4 0.0 0.0 4,151.4 3,925.6 674.5 10,383.7 (0.1)

(0.0)

(0.0)

(8.0)

(0.0)

(0.0)

(20.8)

(19.6)

(3.4)

(51.9) 8.5-9.0 0.0 0.0 0.0 0.0 0.0 0.0 2,027.0 3,109.7 869.9 6,006.5 (0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(10.1)

(15.5)

(4.3)

(30.0)

Texas1 7.0-7.5 1,785.5 0.0 0.1 96.2 0.0 0.0 137.2 0.0 0.0 2,019.1 (8.9)

(0.0)

(0.0)

(0.5)

(0.0)

(0.0)

(0.7)

(0.0)

(0.0)

(10.1) 7.5-8.0 9,046.1 0.0 0.0 1,165.2 0.0 0.1 8,045.2 6,174.7 391.5 24,822.7 (45.2)

(0.0)

(0.0)

(5.8)

(0.0)

(0.0)

(40.2)

(30.9)

(2.0)

(124.1) 8.0-8.5 5,928.5 125.4 0.0 742.1 136.9 0.0 583.5 4,442.8 4,597.1 16,556.3 (29.6)

(0.6)

(0.0)

(3.7)

(0.7)

(0.0)

(2.9)

(22.2)

(23.0)

(82.8) 8.5-9.0 3,798.0 601.0 0.0 42.9 945.1 0.0 0.0 3,210.9 3,674.6 12,272.5 (19.0)

(3.0)

(0.0)

(0.2)

(4.7)

(0.0)

(0.0)

(16.1)

(18.4)

(61.4)

Virginia 7.0-7.5 889.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 889.2 (4.4)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(4.4) 7.5-8.0 3,605.5 15.3 0.0 37.0 0.0 0.0 0.0 0.0 0.0 3,657.8 (18.0)

(0.1)

(0.0)

(0.2)

(0.0)

(0.0)

(0.0)

(0.0)

(0.0)

(18.3) 8.0-8.5 1,135.8 2.0 0.0 2,985.9 0.0 0.0 2,355.9 69.1 0.0 6,548.7 (5.7)

(0.0)

(0.0)

(14.9)

(0.0)

(0.0)

(11.8)

(0.3)

(0.0)

(32.7) 8.5-9.0 0.0 0.0 0.0 23.7 0.0 0.0 2,030.5 4,839.8 900.0 7,794.0 (0.0)

(0.0)

(0.0)

(0.1)

(0.0)

(0.0)

(10.2)

(24.2)

(4.5)

(39.0) 1 Federal waters begin at 3 nm with the exception of Texas, which begins at 9 nm. The area reported for Texas represents 0-9 nm; 9-12 nm; and 12-50 nm respectively.

22 Table 2 (continued). Offshore wind resource area by state with potential by wind speed interval, water depth, distance from shore Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m km2 km2 km2 km2 km2 km2 km2 km2 km2 km2 State m/s (GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

(GW)

Washington 7.0-7.5 622.9 133.5 57.3 231.9 350.2 176.7 0.0 0.0 0.2 1,572.7 (3.1)

(0.7)

(0.3)

(1.2)

(1.8)

(0.9)

(0.0)

(0.0)

(0.0)

(7.9) 7.5-8.0 370.6 0.0 0.0 203.0 841.6 1,173.0 0.0 0.0 2,033.1 4,621.4 (1.9)

(0.0)

(0.0)

(1.0)

(4.2)

(5.9)

(0.0)

(0.0)

(10.2)

(23.1) 8.0-8.5 61.7 0.0 0.0 211.7 977.9 475.1 0.0 19.6 16,514.8 18,260.7 (0.3)

(0.0)

(0.0)

(1.1)

(4.9)

(2.4)

(0.0)

(0.1)

(82.6)

(91.3)

Wisconsin 7.0-7.5 1,053.8 268.2 145.8 349.9 616.6 1,085.0 0.0 34.2 162.0 3,715.4 (5.3)

(1.3)

(0.7)

(1.7)

(3.1)

(5.4)

(0.0)

(0.2)

(0.8)

(18.6) 7.5-8.0 1,417.2 235.5 23.7 361.7 223.0 779.3 0.0 0.0 364.2 3,404.5 (7.1)

(1.2)

(0.1)

(1.8)

(1.1)

(3.9)

(0.0)

(0.0)

(1.8)

(17.0) 8.0-8.5 830.6 372.7 0.0 451.4 1,386.1 2,539.0 0.0 21.3 2,160.1 7,761.1 (4.2)

(1.9)

(0.0)

(2.3)

(6.9)

(12.7)

(0.0)

(0.1)

(10.8)

(38.8) 8.5-9.0 25.5 8.1 0.0 11.7 300.8 1,347.3 0.0 62.8 6,661.0 8,417.3 (0.1)

(0.0)

(0.0)

(0.1)

(1.5)

(6.7)

(0.0)

(0.3)

(33.3)

(42.1)

23 Future Plans The data base is designed to be an evolving product with its elements subject to modification and change. The offshore wind resource is anticipated to undergo notable change as new updated resource maps are completed. The mid-Atlantic states, from Rhode Island to South Carolina, will be the next group of states to be mapped and validated. The database will be modified to include the new information from this region upon completion of the maps. The database will continue to be periodically updated as additional offshore mapping projects are finished along the Atlantic coast of Florida, the Gulf coast, the Pacific coast, and Alaska. The database will eventually contain the wind resource for all 50 states.

Incorporation of environmental exclusions and ocean-use factors impacting offshore wind development will be included in future editions of the database. These exclusions could include many factors including shipping lanes, marine habitat areas, submerged obstacles, military areas, and ocean-bottom topography. In addition, the database may be expanded to include other important characteristics such as wave power density, extreme wind and wave, ocean currents, and a number of other parameters important to the design of offshore wind turbines. Wave power resource estimates are the first type of water power data likely to be included in future versions of the database.

Acknowledgements Thanks to George Scott and Dennis Elliott of the NREL wind resource assessment group for their work in processing and analyzing the offshore wind measurement data. We also thank the staff of AWS Truepower for producing the model data used to create the updated offshore wind resource maps. This paper was written at NREL in support of DOE under contract number DE-AC36-08-GO28308.

References Applied Technology and Management Incorporated. (2007). RIWINDS Final Report Phase 1-Wind Energy Siting Study. 124pp.

Dhanju, A.; P. Whitaker, W Kempton. (2008). Assessing Offshore Wind Resources: An Accessible Methodology. Renewable Energy vol. 33(1) p. 55-64.

Elliott, D.; Holliday, C.; Barchet, W.; Foote, H.; Sandusky, W. (1987). Wind Energy Resource Atlas of the United States. DOE/CH 10093-4, Golden, Colorado: Solar Energy Research Institute.

Elliott, D.; Schwartz, M. (2006). Wind Resource Mapping for United States Offshore Areas:

NREL/CP-500-40045. Golden, Colorado: NREL, 12 pp Federal Register / Vol. 71, No. 1 / Tuesday, January 3, 2006 / Notices, page 127-131

24 Musial, W; Butterfield, C. (2004). Future for Offshore Wind Energy in the United States.

NREL/CP-500-36313 in EnergyOcean Proceedings. Palm Beach, Florida Musial, W. D. (2007). Offshore Wind: Viable Option for Coastal Regions of the United States.

Marine Technology Society Journal, Published Fall 2007.

Thormahlen, L. (1999). Boundary Development of the Outer Continental Shelf. OCS Report MMS99-006.: Department of the Interior Minerals Management Service. Lakewood, Colorado U.S. Department of Energy, Energy Efficiency and Renewable Energy. (2008). 20% Wind Energy by 2030, Increasing Wind Energys Contribution to U.S. Electricity Supply. Executive Summary. DOE/GO 102008-2578. Washington, D.C. 23 pp U.S. Department of the Interior Minerals Management Service. (2007). Programmatic Environmental Impact Statement for Alternative Energy Development and Production and Alternate Use of Facilities on the Outer Continental Shelf - Draft Environmental Impact Statement.

U.S. Department of the Interior Minerals Management Service Web portal http://www.mms.gov/ld/Maps.htm.

U.S. Supreme Court, STATE OF NEW JERSEY, Plaintiff, v. STATE OF DELAWARE, Defendant. No. 134 Original, October Term 2007.

25 Appendix A. Data Sources A1. State-to-State Boundary Data Table A1. State-to-State Boundary Data State Source California 1 NREL digitized line from the MMS SLA line to the California/Oregon state line Connecticut http://www.ct.gov/dep/site/default.asp -

http://www.nyswaterfronts.com/index.asp Georgia http://gis.state.ga.us/

Illinois http://www.isgs.uiuc.edu/nsdihome/ -

http://www.mcgi.state.mi.us/mgdl/

Louisiana 1 http://atlas.lsu.edu/ - http://www.glo.state.tx.us/ - NREL digitized line from the MMS SLA line to the Texas/Louisiana state line Maine http://megis.maine.gov/

Maryland http://www.marylandgis.net/SHAdata/

Massachusetts http://www.whoi.edu/

Michigan http://www.mcgi.state.mi.us/mgdl/

Minnesota http://deli.dnr.state.mn.us/data_catalog.html Mississippi 1 http://www.maris.state.ms.us/ - http://atlas.lsu.edu/ - NREL digitized line from the MMS SLA line to the Mississippi/Alabama state line New Jersey http://www.state.nj.us/dep/njgs/ -

http://www.nyswaterfronts.com/index.asp New York http://www.nyswaterfronts.com/index.asp North Carolina http://www.cgia.state.nc.us/ -

http://www.ors.state.sc.us/digital/gisdata.asp

26 Ohio http://www.dnr.state.oh.us/gims/ - http://www.mcgi.state.mi.us/mgdl/

Oregon 1 NREL digitized line from the MMS SLA line to the Oregon/California and Oregon/Washington state lines Pennsylvania http://nationalatlas.gov/atlasftp.html -

http://www.dnr.state.oh.us/gims/ -

http://www.nyswaterfronts.com/index.asp South Carolina http://www.ors.state.sc.us/digital/gisdata.asp - http://gis.state.ga.us/

Texas 1 http://www.glo.state.tx.us - NREL digitized line from the MMS SLA line to the Texas/Louisiana state line Washington http://www.ecy.wa.gov/services/gis/data/data.htm 1 Environmental Systems Research Institute, Inc. Data & Maps 9.1 Detailed States

27 A2. Wind Map Data Table A2. Wind Map Datasets State Method Preliminary Date Final Date California Old Offshore Map 2002 2002 Connecticut Old Offshore Map 2002 Delaware Old Offshore Map 2002 2003 Georgia Updated Offshore Map 2006 Hawaii Old Offshore Map 2004 Illinois Updated Offshore Map 2008 Indiana Updated Offshore Map 2008 Louisiana Updated Offshore Map 2007 Maine Updated Offshore Map 2008 Maryland Old Offshore Map 2002 2003 Massachusetts Updated Offshore Map 2008 Michigan Updated Offshore Map 2008 Minnesota Updated Offshore Map 2008 New Hampshire Updated Offshore Map 2008 New Jersey Old Offshore Map 2002 2003 New York (Atlantic)

Old Offshore Map 2003 New York (Great Lakes)

Updated Offshore Map 2008 North Carolina Old Offshore Map 2002 2003 Ohio Updated Offshore Map 2008 Oregon Old Offshore Map 2001 2002 Pennsylvania Updated Offshore Map 2008 Rhode Island Old Offshore Map 2002 South Carolina Old Offshore Map 2006 Texas Updated Offshore Map 2007 Virginia Old Offshore Map 2002 2003 Washington Old Offshore Map 2001 2002 Wisconsin Updated Offshore Map 2008

28 Appendix B. Detailed maps and tables B1. United States B2. California B3. Connecticut B4. Delaware B5. Georgia B6. Hawaii B7. Illinois B8. Indiana B9. Louisiana B10. Maine B11. Maryland B12. Massachusetts B13. Michigan B14. Minnesota B15. New Hampshire B16. New Jersey B17. New York B18. North Carolina B19. Ohio B20. Oregon B21. Pennsylvania B22. Rhode Island B23. South Carolina B24. Texas B25. Virginia B26. Washington B27. Wisconsin NOTE: AWS Truepower produced the offshore wind resource estimates under the name AWS Truewind.

29 Appendix B. U.S. Detailed Wind Database Information by Element Table B1. U.S. offshore wind resource by state and wind speed interval. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore.

Wind Speed at 90 m (m/s) 7.0 - 7.5 7.5 - 8.0 8.0 - 8.5 8.5 - 9.0 9.0 - 9.5 9.5 - 10.0

>10.0 Total

>7.0 State Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

California 11,439 24,864 23,059 22,852 13,185 15,231 6,926 117,555 (57,195)

(124,318)

(115,296)

(114,258)

(65,924)

(76,153)

(34,629)

(587,773)

Connecticut 530 702 40 0

0 0

0 1,272 (2,652)

(3,508)

(201)

(0)

(0)

(0)

(0)

(6,360)

Delaware 223 724 1,062 931 0

0 0

2,940 (1,116)

(3,618)

(5,310)

(4,657)

(0)

(0)

(0)

(14,701)

Georgia 3,820 7,741 523 0

0 0

0 12,085 (19,102)

(38,706)

(2,617)

(0)

(0)

(0)

(0)

(60,425)

Hawaii 18,873 42,298 33,042 13,913 7,779 6,720 4,852 127,477 (94,363)

(211,492)

(165,210)

(69,567)

(38,894)

(33,598)

(24,260)

(637,383)

Illinois 92 166 3,844 90 0

0 0

4,192 (458)

(830)

(19,222)

(450)

(0)

(0)

(0)

(20,960)

Indiana 82 216 286 0

0 0

0 584 (410)

(1,082)

(1,428)

(0)

(0)

(0)

(0)

(2,919)

Louisiana 48,043 15,032 0

0 0

0 0

63,075 (240,214)

(75,162)

(0)

(0)

(0)

(0)

(0)

(315,376)

Maine 906 1,142 1,976 3,331 8,429 15,485 42 31,311 (4,531)

(5,711)

(9,878)

(16,655)

(42,146)

(77,424)

(208)

(156,553)

Maryland 2,192 1,946 1,540 5,078 0

0 0

10,756 (10,960)

(9,732)

(7,700)

(25,390)

(0)

(0)

(0)

(53,782)

Massachusetts 202 526 1,639 3,606 20,351 13,674 0

39,997 (1,008)

(2,631)

(8,195)

(18,030)

(101,753)

(68,370)

(0)

(199,987)

Michigan 4,459 18,074 31,086 34,305 8,719 0

0 96,642 (22,297)

(90,368)

(155,430)

(171,524)

(43,593)

(0)

(0)

(483,212)

30 Table B1 (continued). U.S. offshore wind resource by state and wind speed interval. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore.

Wind Speed at 90 m (m/s) 7.0 - 7.5 7.5 - 8.0 8.0 - 8.5 8.5 - 9.0 9.0 - 9.5 9.5 - 10.0

>10.0 Total

>7.0 State Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Minnesota 3,102 994 0

0 0

0 0

4,096 (15,510)

(4,972)

(0)

(0)

(0)

(0)

(0)

(20,481)

New Hampshire 19 46 171 336 102 0

0 672 (93)

(229)

(853)

(1,678)

(508)

(0)

(0)

(3,361)

New Jersey 528 1,508 4,965 12,934 0

0 0

19,935 (2,642)

(7,538)

(24,827)

(64,668)

(0)

(0)

(0)

(99,675)

New York 1,105 4,358 8,324 2,876 7,453 5,322 0

29,439 (5,524)

(21,789)

(41,621)

(14,382)

(37,267)

(26,612)

(0)

(147,194)

North Carolina 1,847 4,098 13,655 39,875 16 0

0 59,491 (9,237)

(20,491)

(68,274)

(199,374)

(80)

(0)

(0)

(297,456)

Ohio 341 3,067 5,829 0

0 0

0 9,237 (1,705)

(15,333)

(29,147)

(0)

(0)

(0)

(0)

(46,186)

Oregon 388 1,493 8,644 13,925 7,394 6,065 5,986 43,894 (1,938)

(7,465)

(43,222)

(69,623)

(36,969)

(30,327)

(29,928)

(219,471)

Pennsylvania 34 211 1,679 0

0 0

0 1,924 (171)

(1,054)

(8,395)

(0)

(0)

(0)

(0)

(9,620)

Rhode Island 224 126 283 671 1,461 2,360 0

5,126 (1,121)

(630)

(1,417)

(3,356)

(7,307)

(11,799)

(0)

(25,631)

South Carolina 1,457 8,202 10,384 6,007 0

0 0

26,049 (7,283)

(41,010)

(51,919)

(30,033)

(0)

(0)

(0)

(130,244)

Texas1 2,019 24,823 16,556 12,273 0

0 0

55,671 (10,095)

(124,114)

(82,782)

(61,363)

(0)

(0)

(0)

(278,353)

Virginia 889 3,658 6,549 7,794 0

0 0

18,890 (4,446)

(18,289)

(32,743)

(38,970)

(0)

(0)

(0)

(94,448)

31 Table B1 (continued). U.S. offshore wind resource by state and wind speed interval. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore.

Wind Speed at 90 m (m/s) 7.0 - 7.5 7.5 - 8.0 8.0 - 8.5 8.5 - 9.0 9.0 - 9.5 9.5 - 10.0

>10.0 Total >7.0 State Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Washington 1,573 4,621 18,261 0

0 0

0 24,455 (7,863)

(23,107)

(91,304)

(0)

(0)

(0)

(0)

(122,274)

Wisconsin 3,715 3,405 7,761 8,417 0

0 0

23,298 (18,577)

(17,023)

(38,806)

(42,087)

(0)

(0)

(0)

(116,492)

Total 108,102 174,040 201,159 189,213 74,888 64,856 17,805 830,064 (540,510)

(870,202)

(1,005,795)

(946,063)

(374,441)

(324,282)

(89,024)

(4,150,319)

32 Table B1.1. U.S. offshore wind resource by state and water depth category. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore.

Shallow (0 - 30m)

Transitional (30 - 60m)

Deep

(> 60m)

Total State Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

California 871 2,091 114,593 117,555 (4,354)

(10,453)

(572,966)

(587,773)

Connecticut 1,152 118 2

1,272 (5,760)

(592)

(8)

(6,360)

Delaware 2,233 707 0

2,940 (11,164)

(3,537)

(0)

(14,701)

Georgia 9,643 2,442 0

12,085 (48,217)

(12,208)

(0)

(60,425)

Hawaii 460 1,106 125,910 127,477 (2,302)

(5,529)

(629,552)

(637,383)

Illinois 1,351 1,017 1,824 4,192 (6,757)

(5,086)

(9,118)

(20,960)

Indiana 584 0

0 584 (2,919)

(0)

(0)

(2,919)

Louisiana 36,698 8,380 17,997 63,075 (183,492)

(41,899)

(89,985)

(315,376)

Maine 3,145 3,048 25,117 31,311 (15,727)

(15,239)

(125,587)

(156,553)

Maryland 6,162 3,258 1,336 10,756 (30,809)

(16,292)

(6,681)

(53,782)

Massachusetts 9,570 11,612 18,816 39,997 (47,849)

(58,059)

(94,079)

(199,987)

Michigan 17,177 15,023 64,442 96,642 (85,887)

(75,115)

(322,210)

(483,212)

Minnesota 5

75 4,016 4,096 (25)

(376)

(20,080)

(20,481)

New Hampshire 116 171 386 672 (579)

(854)

(1,928)

(3,361)

New Jersey 8,696 10,910 329 19,935 (43,480)

(54,549)

(1,647)

(99,675)

New York 7,496 11,253 10,690 29,439 (37,481)

(56,263)

(53,450)

(147,194)

North Carolina 28,006 15,544 15,942 59,491 (140,029)

(77,719)

(79,708)

(297,456)

Ohio 9,237 0

0 9,237 (46,186)

(0)

(0)

(46,186)

Oregon 1,319 1,946 40,630 43,894 (6,595)

(9,728)

(203,148)

(219,471)

33 Table B1.1 (continued). U.S. offshore wind resource by state and water depth category. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore.

Shallow (0 - 30m)

Transitional (30 - 60m)

Deep

(> 60m)

Total State Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Pennsylvania 1,451 473 0

1,924 (7,253)

(2,367)

(0)

(9,620)

Rhode Island 1,048 2,691 1,388 5,126 (5,238)

(13,453)

(6,940)

(25,631)

South Carolina 17,182 7,322 1,544 26,049 (85,911)

(36,611)

(7,722)

(130,244)

Texas1 31,370 15,637 8,663 55,671 (156,852)

(78,184)

(43,317)

(278,353)

Virginia 13,063 4,926 900 18,890 (65,317)

(24,631)

(4,500)

(94,448)

Washington 1,702 2,323 20,430 24,455 (8,509)

(11,614)

(102,151)

(122,274)

Wisconsin 4,502 3,529 15,267 23,298 (22,508)

(17,647)

(76,337)

(116,492)

Total 214,240 125,601 490,223 830,064 (1,071,202)

(628,004)

(2,451,113)

(4,150,319)

34 Table B1.2. U.S. offshore wind resource by state and distance from shore. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore.

0 - 3 nm 3 - 12 nm 12 - 50 nm Total State Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

California 2,447 20,824 94,283 117,555 (12,237)

(104,121)

(471,416)

(587,773)

Connecticut 1,272 0

0 1,272 (6,360)

(0)

(0)

(6,360)

Delaware 1,088 672 1,181 2,940 (5,438)

(3,359)

(5,904)

(14,701)

Georgia 633 2,692 8,760 12,085 (3,164)

(13,459)

(43,802)

(60,425)

Hawaii 13,455 19,794 94,228 127,477 (67,275)

(98,971)

(471,138)

(637,383)

Illinois 501 1,573 2,117 4,192 (2,507)

(7,867)

(10,586)

(20,960)

Indiana 337 247 0

584 (1,687)

(1,233)

(0)

(2,919)

Louisiana 7,944 11,554 43,578 63,075 (39,718)

(57,768)

(217,891)

(315,376)

Maine 5,483 7,919 17,909 31,311 (27,416)

(39,594)

(89,543)

(156,553)

Maryland 4,292 934 5,531 10,756 (21,459)

(4,670)

(27,653)

(53,782)

Massachusetts 5,392 7,087 27,519 39,997 (26,958)

(35,436)

(137,593)

(199,987)

Michigan 15,814 36,855 43,973 96,642 (79,068)

(184,277)

(219,867)

(483,212)

Minnesota 334 1,810 1,952 4,096 (1,670)

(9,052)

(9,759)

(20,481)

New Hampshire 154 364 154 672 (769)

(1,822)

(770)

(3,361)

New Jersey 2,271 3,665 13,999 19,935 (11,353)

(18,327)

(69,995)

(99,675)

New York 6,232 8,920 14,287 29,439 (31,159)

(44,602)

(71,434)

(147,194)

North Carolina 8,875 8,985 41,632 59,491 (44,373)

(44,923)

(208,160)

(297,456)

Ohio 2,013 4,153 3,071 9,237 (10,065)

(20,765)

(15,356)

(46,186)

Oregon 2,255 8,575 33,064 43,894 (11,274)

(42,876)

(165,320)

(219,471)

35 Table B1.2 (continued). U.S. offshore wind resource by state and distance from shore. Resource areas limited to >7.0 m/s at 90-m height and within 50 nm of shore.

0 - 3 nm 3 - 12 nm 12 - 50 nm Total State Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Pennsylvania 425 1,206 293 1,924 (2,123)

(6,032)

(1,465)

(9,620)

Rhode Island 815 1,526 2,785 5,126 (4,074)

(7,630)

(13,927)

(25,631)

South Carolina 1,465 5,272 19,313 26,049 (7,323)

(26,358)

(96,563)

(130,244)

Texas1 21,285 3,128 31,257 55,671 (106,423)

(15,642)

(156,287)

(278,353)

Virginia 5,648 3,047 10,195 18,890 (28,239)

(15,233)

(50,976)

(94,448)

Washington 1,246 4,641 18,568 24,455 (6,230)

(23,205)

(92,839)

(122,274)

Wisconsin 4,381 9,452 9,466 23,298 (21,905)

(47,258)

(47,328)

(116,492)

Total 116,053 174,896 539,114 830,064 (580,267)

(874,481)

(2,695,572)

(4,150,319) 1 Federal waters begin at 3 nm with the exception of Texas, which begins at 9 nm. For Texas, the area reported is for 0 - 9 nm; 9 - 12 nm; and 12 - 50 nm respectively.

36 Table B1.3. Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

State m/s (MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

California 7.0-7.5 266.2 236.2 257.4 100.9 456.8 4,554.0 7.7 22.9 5,536.8 11,438.9 (1,331)

(1,181)

(1,287)

(504)

(2,284)

(22,770)

(38)

(115)

(27,684)

(57,195) 7.5-8.0 239.1 256.9 189.6 78.8 595.7 3,854.6 0.0 32.9 19,616.1 24,863.7 (1,196)

(1,285)

(948)

(394)

(2,978)

(19,273)

(0)

(165)

(98,080)

(124,318) 8.0-8.5 125.2 178.2 281.8 7.1 105.8 4,539.1 0.0 0.0 17,822.2 23,059.3 (626)

(891)

(1,409)

(36)

(529)

(22,695)

(0)

(0)

(89,111)

(115,296) 8.5-9.0 43.2 141.7 176.4 0.6 38.0 4,559.8 0.0 0.0 17,892.0 22,851.6 (216)

(708)

(882)

(3)

(190)

(22,799)

(0)

(0)

(89,460)

(114,258) 9.0-9.5 2.1 18.8 14.9 0.0 0.9 988.0 0.0 0.0 12,160.2 13,184.8 (10)

(94)

(74)

(0)

(4)

(4,940)

(0)

(0)

(60,801)

(65,924) 9.5-10.0 0.0 6.0 13.9 0.0 0.0 656.1 0.0 0.0 14,554.8 15,230.7 (0)

(30)

(69)

(0)

(0)

(3,280)

(0)

(0)

(72,774)

(76,153)

>10.0 0.0 0.0 0.1 0.0 0.0 288.1 0.0 0.0 6,637.6 6,925.8 (0)

(0)

(1)

(0)

(0)

(1,441)

(0)

(0)

(33,188)

(34,629)

Connecticut 7.0-7.5 500.1 30.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 530.4 (2,501)

(151)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(2,652) 7.5-8.0 617.3 83.0 1.2 0.0 0.0 0.0 0.0 0.0 0.0 701.6 (3,087)

(415)

(6)

(0)

(0)

(0)

(0)

(0)

(0)

(3,508) 8.0-8.5 34.6 5.0 0.4 0.0 0.0 0.0 0.0 0.0 0.0 40.1 (173)

(25)

(2)

(0)

(0)

(0)

(0)

(0)

(0)

(201)

Delaware 7.0-7.5 223.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 223.2 (1,116)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(1,116) 7.5-8.0 716.5 2.0 0.0 5.2 0.0 0.0 0.0 0.0 0.0 723.7 (3,583)

(10)

(0)

(26)

(0)

(0)

(0)

(0)

(0)

(3,618) 8.0-8.5 135.4 10.5 0.0 658.0 8.6 0.0 240.4 8.9 0.0 1,061.9 (677)

(53)

(0)

(3,290)

(43)

(0)

(1,202)

(44)

(0)

(5,310) 8.5-9.0 0.0 0.0 0.0 0.0 0.0 0.0 254.0 677.4 0.0 931.4 (0)

(0)

(0)

(0)

(0)

(0)

(1,270)

(3,387)

(0)

(4,657)

37 Table B.1.3 (continued) Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

State m/s (MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

Georgia 7.0-7.5 547.5 0.0 0.0 2,162.3 0.0 0.0 1,110.6 0.0 0.0 3,820.4 (2,737)

(0)

(0)

(10,811)

(0)

(0)

(5,553)

(0)

(0)

(19,102) 7.5-8.0 85.2 0.0 0.0 529.6 0.0 0.0 5,204.3 1,922.1 0.0 7,741.2 (426)

(0)

(0)

(2,648)

(0)

(0)

(26,021)

(9,610)

(0)

(38,706) 8.0-8.5 0.0 0.0 0.0 0.0 0.0 0.0 3.9 519.5 0.0 523.4 (0)

(0)

(0)

(0)

(0)

(0)

(19)

(2,598)

(0)

(2,617)

Hawaii 7.0-7.5 111.5 97.2 2,631.5 0.0 42.6 2,213.3 44.4 116.8 13,615.3 18,872.6 (557)

(486)

(13,157)

(0)

(213)

(11,067)

(222)

(584)

(68,077)

(94,363) 7.5-8.0 65.5 107.0 2,404.0 0.0 145.0 5,051.6 6.9 250.7 34,267.6 42,298.3 (328)

(535)

(12,020)

(0)

(725)

(25,258)

(34)

(1,254)

(171,338)

(211,492) 8.0-8.5 92.2 114.8 2,364.3 0.0 15.0 4,755.7 0.2 0.3 25,699.5 33,042.0 (461)

(574)

(11,822)

(0)

(75)

(23,778)

(1)

(1)

(128,498)

(165,210) 8.5-9.0 65.6 67.0 2,105.2 0.0 0.0 2,625.5 0.0 0.0 9,050.0 13,913.3 (328)

(335)

(10,526)

(0)

(0)

(13,128)

(0)

(0)

(45,250)

(69,567) 9.0-9.5 25.7 39.0 995.6 0.0 0.0 1,853.0 0.0 0.0 4,865.5 7,778.8 (129)

(195)

(4,978)

(0)

(0)

(9,265)

(0)

(0)

(24,328)

(38,894) 9.5-10.0 22.0 39.8 666.0 0.0 0.0 1,064.9 0.0 0.0 4,926.8 6,719.6 (110)

(199)

(3,330)

(0)

(0)

(5,324)

(0)

(0)

(24,634)

(33,598)

>10.0 26.3 70.5 1,344.0 0.0 0.0 2,027.6 0.0 0.0 1,383.5 4,852.0 (132)

(353)

(6,720)

(0)

(0)

(10,138)

(0)

(0)

(6,918)

(24,260)

Illinois 7.0-7.5 91.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 91.6 (458)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(458) 7.5-8.0 164.6 0.0 0.0 0.0 0.1 0.0 0.0 1.3 0.0 166.0 (823)

(0)

(0)

(0)

(1)

(0)

(0)

(6)

(0)

(830) 8.0-8.5 244.2 1.0 0.0 830.4 512.2 140.7 7.1 426.1 1,682.8 3,844.5 (1,221)

(5)

(0)

(4,152)

(2,561)

(704)

(35)

(2,130)

(8,414)

(19,222) 8.5-9.0 0.0 0.0 0.0 13.4 76.6 0.0 0.0 0.0 0.0 89.9 (0)

(0)

(0)

(67)

(383)

(0)

(0)

(0)

(0)

(450)

38 Table B.1.3 (continued) Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

State m/s (MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

Indiana 7.0-7.5 82.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 82.1 (410)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(410) 7.5-8.0 153.8 0.0 0.0 62.6 0.0 0.0 0.0 0.0 0.0 216.3 (769)

(0)

(0)

(313)

(0)

(0)

(0)

(0)

(0)

(1,082) 8.0-8.5 101.5 0.0 0.0 184.0 0.0 0.0 0.0 0.0 0.0 285.5 (507)

(0)

(0)

(920)

(0)

(0)

(0)

(0)

(0)

(1,428)

Louisiana 7.0-7.5 7,759.6 28.6 0.0 7,825.2 643.4 1,460.4 11,163.9 5,479.1 13,682.4 48,042.7 (38,798)

(143)

(0)

(39,126)

(3,217)

(7,302)

(55,819)

(27,396)

(68,412)

(240,214) 7.5-8.0 155.3 0.0 0.0 1,624.5 0.0 0.0 8,169.9 2,228.7 2,854.1 15,032.5 (776)

(0)

(0)

(8,123)

(0)

(0)

(40,850)

(11,143)

(14,271)

(75,162)

Maine 7.0-7.5 787.0 91.2 11.9 7.8 4.8 3.5 0.0 0.0 0.0 906.2 (3,935)

(456)

(59)

(39)

(24)

(18)

(0)

(0)

(0)

(4,531) 7.5-8.0 797.2 285.4 19.4 6.7 19.6 14.1 0.0 0.0 0.0 1,142.3 (3,986)

(1,427)

(97)

(33)

(98)

(70)

(0)

(0)

(0)

(5,711) 8.0-8.5 777.0 440.8 74.2 63.4 385.6 234.5 0.0 0.0 0.0 1,975.6 (3,885)

(2,204)

(371)

(317)

(1,928)

(1,173)

(0)

(0)

(0)

(9,878) 8.5-9.0 513.4 614.0 157.6 18.2 219.1 1,401.9 0.0 0.0 406.8 3,331.1 (2,567)

(3,070)

(788)

(91)

(1,095)

(7,010)

(0)

(0)

(2,034)

(16,655) 9.0-9.5 142.2 390.0 309.2 25.9 469.0 3,504.1 0.0 57.8 3,530.9 8,429.2 (711)

(1,950)

(1,546)

(129)

(2,345)

(17,520)

(0)

(289)

(17,655)

(42,146) 9.5-10.0 5.5 24.9 42.3 1.0 38.3 1,459.8 0.0 7.4 13,905.6 15,484.7 (28)

(124)

(211)

(5)

(191)

(7,299)

(0)

(37)

(69,528)

(77,424)

>10.0 0.0 0.0 0.0 0.0 0.0 41.6 0.0 0.0 0.0 41.6 (0)

(0)

(0)

(0)

(0)

(208)

(0)

(0)

(0)

(208)

Maryland 7.0-7.5 2,175.4 16.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2,192.0 (10,877)

(83)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(10,960) 7.5-8.0 1,922.5 14.0 0.0 9.9 0.0 0.0 0.0 0.0 0.0 1,946.4 (9,613)

(70)

(0)

(49)

(0)

(0)

(0)

(0)

(0)

(9,732)

39 Table B.1.3 (continued) Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

State m/s (MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

Maryland 8.0-8.5 163.3 0.0 0.0 924.0 0.0 0.0 435.4 17.2 0.0 1,539.9 (cont.)

(817)

(0)

(0)

(4,620)

(0)

(0)

(2,177)

(86)

(0)

(7,700) 8.5-9.0 0.0 0.0 0.0 0.0 0.0 0.0 531.3 3,210.7 1,336.1 5,078.1 (0)

(0)

(0)

(0)

(0)

(0)

(2,656)

(16,053)

(6,681)

(25,390)

Massachusetts 7.0-7.5 201.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 201.6 (1,008)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(1,008) 7.5-8.0 521.4 4.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 526.1 (2,607)

(23)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(2,631) 8.0-8.5 927.4 327.3 28.6 78.2 152.0 125.5 0.0 0.0 0.0 1,639.1 (4,637)

(1,636)

(143)

(391)

(760)

(628)

(0)

(0)

(0)

(8,195) 8.5-9.0 1,508.2 378.1 12.6 315.0 354.5 812.2 11.4 23.5 190.4 3,606.0 (7,541)

(1,890)

(63)

(1,575)

(1,773)

(4,061)

(57)

(118)

(952)

(18,030) 9.0-9.5 1,137.0 322.6 20.0 2,696.9 1,418.6 1,006.5 1,689.9 5,051.8 7,007.4 20,350.7 (5,685)

(1,613)

(100)

(13,484)

(7,093)

(5,033)

(8,449)

(25,259)

(35,037)

(101,753) 9.5-10.0 2.0 0.0 0.0 8.6 119.2 0.0 472.1 3,459.5 9,612.5 13,674.0 (10)

(0)

(0)

(43)

(596)

(0)

(2,361)

(17,298)

(48,063)

(68,370)

Michigan 7.0-7.5 3,411.4 330.6 243.7 142.6 49.8 268.0 1.2 0.0 12.1 4,459.3 (17,057)

(1,653)

(1,218)

(713)

(249)

(1,340)

(6)

(0)

(61)

(22,297) 7.5-8.0 4,632.7 1,258.2 635.3 3,069.0 2,916.4 2,991.0 14.2 108.5 2,448.4 18,073.7 (23,163)

(6,291)

(3,177)

(15,345)

(14,582)

(14,955)

(71)

(542)

(12,242)

(90,368) 8.0-8.5 2,588.1 1,253.3 769.0 2,770.6 5,889.7 9,411.9 30.9 876.1 7,496.4 31,085.9 (12,940)

(6,267)

(3,845)

(13,853)

(29,448)

(47,059)

(155)

(4,381)

(37,482)

(155,430) 8.5-9.0 138.7 156.2 396.5 145.1 550.6 8,580.8 118.5 1,383.9 22,834.5 34,304.7 (693)

(781)

(1,983)

(726)

(2,753)

(42,904)

(592)

(6,920)

(114,172)

(171,524) 9.0-9.5 0.0 0.0 0.0 0.0 0.0 69.9 114.6 249.6 8,284.5 8,718.7 (0)

(0)

(0)

(0)

(0)

(350)

(573)

(1,248)

(41,423)

(43,593)

Minnesota 7.0-7.5 5.1 43.6 272.6 0.0 31.5 1,718.1 0.0 0.0 1,031.1 3,101.9 (25)

(218)

(1,363)

(0)

(158)

(8,590)

(0)

(0)

(5,155)

(15,510) 7.5-8.0 0.0 0.1 12.7 0.0 0.0 60.8 0.0 0.0 920.7 994.3 (0)

(0)

(64)

(0)

(0)

(304)

(0)

(0)

(4,603)

(4,972)

40 Table B.1.3 (continued) Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

State m/s (MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

New Hampshire 7.0-7.5 18.6 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 18.6 (93)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(93) 7.5-8.0 45.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 45.8 (229)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(229) 8.0-8.5 44.6 29.7 0.0 6.9 75.5 14.0 0.0 0.0 0.0 170.6 (223)

(148)

(0)

(34)

(378)

(70)

(0)

(0)

(0)

(853) 8.5-9.0 0.0 8.0 7.2 0.0 12.4 255.7 0.0 10.1 42.2 335.7 (0)

(40)

(36)

(0)

(62)

(1,279)

(0)

(51)

(211)

(1,678) 9.0-9.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 35.2 66.4 101.6 (0)

(0)

(0)

(0)

(0)

(0)

(0)

(176)

(332)

(508)

New Jersey 7.0-7.5 520.2 0.0 0.0 8.2 0.0 0.0 0.0 0.0 0.0 528.5 (2,601)

(0)

(0)

(41)

(0)

(0)

(0)

(0)

(0)

(2,642) 7.5-8.0 960.4 0.0 0.0 518.6 27.9 0.7 0.0 0.0 0.0 1,507.6 (4,802)

(0)

(0)

(2,593)

(140)

(4)

(0)

(0)

(0)

(7,538) 8.0-8.5 776.9 0.0 0.0 2,764.8 127.1 3.2 899.4 372.4 21.6 4,965.4 (3,885)

(0)

(0)

(13,824)

(636)

(16)

(4,497)

(1,862)

(108)

(24,827) 8.5-9.0 13.1 0.0 0.0 214.7 0.0 0.0 2,019.5 10,382.4 303.8 12,933.5 (66)

(0)

(0)

(1,074)

(0)

(0)

(10,098)

(51,912)

(1,519)

(64,668)

New York 7.0-7.5 1,047.9 54.2 0.0 2.8 0.0 0.0 0.0 0.0 0.0 1,104.8 (5,239)

(271)

(0)

(14)

(0)

(0)

(0)

(0)

(0)

(5,524) 7.5-8.0 1,983.1 354.7 11.6 472.7 609.0 866.8 0.0 0.0 59.9 4,357.8 (9,915)

(1,774)

(58)

(2,363)

(3,045)

(4,334)

(0)

(0)

(300)

(21,789) 8.0-8.5 1,329.3 602.9 196.5 375.6 535.7 3,122.0 42.2 12.6 2,107.4 8,324.1 (6,646)

(3,015)

(982)

(1,878)

(2,679)

(15,610)

(211)

(63)

(10,537)

(41,621) 8.5-9.0 535.1 110.6 0.6 1,042.6 93.8 0.0 261.5 727.8 104.5 2,876.4 (2,675)

(553)

(3)

(5,213)

(469)

(0)

(1,307)

(3,639)

(522)

(14,382) 9.0-9.5 5.4 0.0 0.0 391.9 1,407.6 0.0 6.4 4,926.1 716.0 7,453.3 (27)

(0)

(0)

(1,959)

(7,038)

(0)

(32)

(24,631)

(3,580)

(37,267) 9.5-10.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1,817.6 3,504.8 5,322.4 (0)

(0)

(0)

(0)

(0)

(0)

(0)

(9,088)

(17,524)

(26,612)

41 Table B.1.3 (continued) Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

State m/s (MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

North Carolina 7.0-7.5 1,847.4 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 1,847.4 (9,237)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(9,237) 7.5-8.0 3,002.1 0.0 0.0 1,096.1 0.0 0.0 0.0 0.0 0.0 4,098.3 (15,010)

(0)

(0)

(5,481)

(0)

(0)

(0)

(0)

(0)

(20,491) 8.0-8.5 3,920.0 0.1 0.1 4,653.8 0.0 0.0 4,034.9 746.5 299.2 13,654.7 (19,600)

(1)

(0)

(23,269)

(0)

(0)

(20,174)

(3,733)

(1,496)

(68,274) 8.5-9.0 105.0 0.0 0.0 2,964.1 261.4 8.9 6,382.4 14,519.6 15,633.3 39,874.8 (525)

(0)

(0)

(14,821)

(1,307)

(45)

(31,912)

(72,598)

(78,167)

(199,374) 9.0-9.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 16.0 0.0 16.0 (0)

(0)

(0)

(0)

(0)

(0)

(0)

(80)

(0)

(80)

Ohio 7.0-7.5 341.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 341.0 (1,705)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(1,705) 7.5-8.0 1,106.8 0.0 0.0 1,959.8 0.0 0.0 0.0 0.0 0.0 3,066.7 (5,534)

(0)

(0)

(9,799)

(0)

(0)

(0)

(0)

(0)

(15,333) 8.0-8.5 565.2 0.0 0.0 2,193.1 0.0 0.0 3,071.2 0.0 0.0 5,829.5 (2,826)

(0)

(0)

(10,965)

(0)

(0)

(15,356)

(0)

(0)

(29,147)

Oregon 7.0-7.5 355.8 20.6 0.0 0.9 9.2 1.2 0.0 0.0 0.0 387.6 (1,779)

(103)

(0)

(4)

(46)

(6)

(0)

(0)

(0)

(1,938) 7.5-8.0 523.0 319.2 37.6 46.5 231.8 335.0 0.0 0.0 0.0 1,493.0 (2,615)

(1,596)

(188)

(232)

(1,159)

(1,675)

(0)

(0)

(0)

(7,465) 8.0-8.5 198.3 277.0 6.6 19.0 595.7 2,558.5 0.0 0.0 4,989.5 8,644.4 (991)

(1,385)

(33)

(95)

(2,978)

(12,792)

(0)

(0)

(24,947)

(43,222) 8.5-9.0 64.1 98.8 0.6 0.0 108.0 1,967.2 0.0 45.6 11,640.3 13,924.6 (320)

(494)

(3)

(0)

(540)

(9,836)

(0)

(228)

(58,201)

(69,623) 9.0-9.5 64.1 55.4 38.6 0.0 32.6 614.9 0.0 0.0 6,588.2 7,393.7 (321)

(277)

(193)

(0)

(163)

(3,074)

(0)

(0)

(32,941)

(36,969) 9.5-10.0 47.3 80.4 14.6 0.0 33.8 634.6 0.0 0.0 5,254.6 6,065.3 (237)

(402)

(73)

(0)

(169)

(3,173)

(0)

(0)

(26,273)

(30,327)

>10.0 0.2 19.4 33.3 0.0 18.2 1,368.5 0.0 0.0 4,546.0 5,985.5 (1)

(97)

(166)

(0)

(91)

(6,843)

(0)

(0)

(22,730)

(29,928)

42 Table B.1.3 (continued) Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

State m/s (MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

Pennsylvania 7.0-7.5 34.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 34.2 (171)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(171) 7.5-8.0 113.4 0.0 0.0 53.2 44.2 0.0 0.0 0.0 0.0 210.8 (567)

(0)

(0)

(266)

(221)

(0)

(0)

(0)

(0)

(1,054) 8.0-8.5 276.2 0.9 0.0 750.8 358.1 0.0 222.9 70.2 0.0 1,679.1 (1,381)

(4)

(0)

(3,754)

(1,790)

(0)

(1,114)

(351)

(0)

(8,395)

Rhode Island 7.0-7.5 216.3 8.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 224.3 (1,082)

(40)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(1,121) 7.5-8.0 123.2 2.8 0.0 0.0 0.0 0.0 0.0 0.0 0.0 126.0 (616)

(14)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(630) 8.0-8.5 139.9 39.8 0.0 34.5 69.2 0.0 0.0 0.0 0.0 283.5 (700)

(199)

(0)

(173)

(346)

(0)

(0)

(0)

(0)

(1,417) 8.5-9.0 120.3 93.0 0.0 183.6 274.2 0.0 0.0 0.0 0.0 671.2 (602)

(465)

(0)

(918)

(1,371)

(0)

(0)

(0)

(0)

(3,356) 9.0-9.5 53.7 17.6 0.0 176.0 782.7 0.0 0.0 430.2 1.3 1,461.5 (269)

(88)

(0)

(880)

(3,914)

(0)

(0)

(2,151)

(6)

(7,307) 9.5-10.0 0.0 0.0 0.0 0.0 5.8 0.0 0.0 967.2 1,386.8 2,359.8 (0)

(0)

(0)

(0)

(29)

(0)

(0)

(4,836)

(6,934)

(11,799)

South Carolina 7.0-7.5 848.2 0.0 0.0 608.4 0.0 0.0 0.0 0.0 0.0 1,456.5 (4,241)

(0)

(0)

(3,042)

(0)

(0)

(0)

(0)

(0)

(7,283) 7.5-8.0 593.5 0.0 0.0 3,053.9 0.0 0.0 4,267.6 287.0 0.0 8,202.1 (2,968)

(0)

(0)

(15,269)

(0)

(0)

(21,338)

(1,435)

(0)

(41,010) 8.0-8.5 22.9 0.0 0.0 1,609.4 0.0 0.0 4,151.4 3,925.6 674.5 10,383.7 (115)

(0)

(0)

(8,047)

(0)

(0)

(20,757)

(19,628)

(3,372)

(51,919) 8.5-9.0 0.0 0.0 0.0 0.0 0.0 0.0 2,027.0 3,109.7 869.9 6,006.5 (0)

(0)

(0)

(0)

(0)

(0)

(10,135)

(15,548)

(4,349)

(30,033)

43 Table B.1.3 (cont'd) Offshore wind resource by state, wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shoreline 0 - 3 nm1 3 - 12 nm 12 - 50 nm Wind Depth Category (m)

Depth Category (m)

Depth Category (m)

Speed 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 0 - 30 30 - 60

> 60 Total at 90m Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

Area (km2)

State m/s (MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

(MW)

Texas1 7.0-7.5 1,785.5 0.0 0.1 96.2 0.0 0.0 137.2 0.0 0.0 2,019.1 (8,928)

(0)

(1)

(481)

(0)

(0)

(686)

(0)

(0)

(10,095) 7.5-8.0 9,046.1 0.0 0.0 1,165.2 0.0 0.1 8,045.2 6,174.7 391.5 24,822.7 (45,230)

(0)

(0)

(5,826)

(0)

(0)

(40,226)

(30,873)

(1,958)

(124,114) 8.0-8.5 5,928.5 125.4 0.0 742.1 136.9 0.0 583.5 4,442.8 4,597.1 16,556.3 (29,643)

(627)

(0)

(3,711)

(684)

(0)

(2,918)

(22,214)

(22,985)

(82,782) 8.5-9.0 3,798.0 601.0 0.0 42.9 945.1 0.0 0.0 3,210.9 3,674.6 12,272.5 (18,990)

(3,005)

(0)

(215)

(4,726)

(0)

(0)

(16,055)

(18,373)

(61,363)

Virginia 7.0-7.5 889.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 889.2 (4,446)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(4,446) 7.5-8.0 3,605.5 15.3 0.0 37.0 0.0 0.0 0.0 0.0 0.0 3,657.8 (18,028)

(77)

(0)

(185)

(0)

(0)

(0)

(0)

(0)

(18,289) 8.0-8.5 1,135.8 2.0 0.0 2,985.9 0.0 0.0 2,355.9 69.1 0.0 6,548.7 (5,679)

(10)

(0)

(14,929)

(0)

(0)

(11,780)

(345)

(0)

(32,743) 8.5-9.0 0.0 0.0 0.0 23.7 0.0 0.0 2,030.5 4,839.8 900.0 7,794.0 (0)

(0)

(0)

(119)

(0)

(0)

(10,152)

(24,199)

(4,500)

(38,970)

Washington 7.0-7.5 622.9 133.5 57.3 231.9 350.2 176.7 0.0 0.0 0.2 1,572.7 (3,115)

(667)

(286)

(1,159)

(1,751)

(884)

(0)

(0)

(1)

(7,863) 7.5-8.0 370.6 0.0 0.0 203.0 841.6 1,173.0 0.0 0.0 2,033.1 4,621.4 (1,853)

(0)

(0)

(1,015)

(4,208)

(5,865)

(0)

(0)

(10,166)

(23,107) 8.0-8.5 61.7 0.0 0.0 211.7 977.9 475.1 0.0 19.6 16,514.8 18,260.7 (308)

(0)

(0)

(1,059)

(4,889)

(2,375)

(0)

(98)

(82,574)

(91,304)

Wisconsin 7.0-7.5 1,053.8 268.2 145.8 349.9 616.6 1,085.0 0.0 34.2 162.0 3,715.4 (5,269)

(1,341)

(729)

(1,749)

(3,083)

(5,425)

(0)

(171)

(810)

(18,577) 7.5-8.0 1,417.2 235.5 23.7 361.7 223.0 779.3 0.0 0.0 364.2 3,404.5 (7,086)

(1,177)

(119)

(1,808)

(1,115)

(3,896)

(0)

(0)

(1,821)

(17,023) 8.0-8.5 830.6 372.7 0.0 451.4 1,386.1 2,539.0 0.0 21.3 2,160.1 7,761.1 (4,153)

(1,863)

(0)

(2,257)

(6,930)

(12,695)

(0)

(107)

(10,800)

(38,806) 8.5-9.0 25.5 8.1 0.0 11.7 300.8 1,347.3 0.0 62.8 6,661.0 8,417.3 (128)

(41)

(0)

(58)

(1,504)

(6,737)

(0)

(314)

(33,305)

(42,087) 1 Federal waters begin at 3 nm with the exception of Texas, which begins at 9 nm. For Texas, area reported is 0 - 9, 9 - 12; and 12 - 50 nm.

44 Figure B1. United States offshore wind resource at 90 m above the surface.

45 Table B2. California offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 266 236 257 101 457 4,554 8

23 5,537 (1,331)

(1,181)

(1,287)

(504)

(2,284)

(22,770)

(38)

(115)

(27,684) 7.5 - 8.0 239 257 190 79 596 3,855 0

33 19,616 (1,196)

(1,285)

(948)

(394)

(2,978)

(19,273)

(0)

(165)

(98,080) 8.0 - 8.5 125 178 282 7

106 4,539 0

0 17,822 (626)

(891)

(1,409)

(36)

(529)

(22,695)

(0)

(0)

(89,111) 8.5 - 9.0 43 142 176 1

38 4,560 0

0 17,892 (216)

(708)

(882)

(3)

(190)

(22,799)

(0)

(0)

(89,460) 9.0 - 9.5 2

19 15 0

1 988 0

0 12,160 (10)

(94)

(74)

(0)

(4)

(4,940)

(0)

(0)

(60,801) 9.5 - 10.0 0

6 14 0

0 656 0

0 14,555 (0)

(30)

(69)

(0)

(0)

(3,280)

(0)

(0)

(72,774)

>10.0 0

0 0

0 0

288 0

0 6,638 (0)

(0)

(1)

(0)

(0)

(1,441)

(0)

(0)

(33,188)

Total >7.0 676 838 934 187 1,197 19,440 8

56 94,220 (3,379)

(4,189)

(4,670)

(937)

(5,985)

(97,198)

(38)

(279)

(471,098)

46 Figure B2. California detailed map California - 90 m Offshore Wind Speed 126" 124" 122" 120" 11S" 42" fT7 ------t---:----t-- - ----i-- -W 42" 40" 38" r---1t-l~~F+~~~~~~--~ 38"r-------~

Contours 36" The offshore wind resource data was originally estimated by AWS Truewind as part of an onshore wind mapping project. These data have been Interpolated to 90 m and extrapolated to 50 nautical miles by NREL.

Wind Speed at 90 m mi.

mph Water Depth (Meters)

Distance from Shore (Nautical Miles) 11.5-12.0 11.0-11.5 10.5 -11.0 10.0 - 10.5 9.5 - 10.0 9.0-9.5 8.5 - 9.0 8.0-8.5 7.5 - 8.0 7.0- 7.5 6.5-7.0 6.0- 6.5 0.0- 6.0 25.7 - 26.8 24.S - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0 - 20.1 17.9 -19.0 16.8 - 17.9 15.7 - 16.8 14.5 - 15.7 13.4 - 14.5 0.0 -13.4 I=t=====::::!::::=~~~~=~

32" 120" 11S" lO:::0~~=..:.0===="

'0:::0~ __

.:200

~==o=;

300 Kilometen; 5O_~~~"=====50 ___.';;OOc====':;50 Nautical Miles

()~IE!.

U.S. Department of Energy National Renewable Energy Laboratory

47 Table B3. Connecticut offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 500 30 0

0 0

0 0

0 0

(2,501)

(151)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 617 83 1

0 0

0 0

0 0

(3,087)

(415)

(6)

(0)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 35 5

0 0

0 0

0 0

0 (173)

(25)

(2)

(0)

(0)

(0)

(0)

(0)

(0) 8.5 - 9.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 1,152 118 2

0 0

0 0

0 0

(5,760)

(592)

(8)

(0)

(0)

(0)

(0)

(0)

(0)

48 Figure B3. Connecticut detailed map 41*

Wind Speed at 90 m mi.

11.5 -12.0 11.0 -11.5 10.5 -11.0 10.0 -10.5 9.5 - 10.0 9.0- 9.5 8.5-9.0 8.0-8.5 7.5 - 8.0 7.0-7.5 6.5-7.0 6.0- 6.5 0.0- 6.0 mph 25.7 - 26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1 - 21.3 19.0 - 20.1 17.9 -19.0 16.8 - 17.9 15.7 -16.8 14.5 - 15.7 13.4 - 14.5 0.0 - 13.4 Connecticut - 90 m Offshore Wind Speed 73*

73*

The offshore wind resource data was originally estimated by AWS Truewlnd as part of an onshore wind mapping project These data have been Interpolated to 90 m and extrapolated to 50 nautical miles by NREL 10 o

o 10 72*

Contours Water Depth (Meters)

Distance from Snore (Nautical Miles)

The data for offshore distance from the shore Is not available for the Long Island Sound.

20 30 40 Kiometen; 10 15 20 NsutiCBI Miles U.S. Department of Energy National Renewable Energy Laboratory

49 Table B4. Delaware offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 223 0

0 0

0 0

0 0

0 (1,116)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 717 2

0 5

0 0

0 0

0 (3,583)

(10)

(0)

(26)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 135 11 0

658 9

0 240 9

0 (677)

(53)

(0)

(3,290)

(43)

(0)

(1,202)

(44)

(0) 8.5 - 9.0 0

0 0

0 0

0 254 677 0

(0)

(0)

(0)

(0)

(0)

(0)

(1,270)

(3,387)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 1,075 13 0

663 9

0 494 686 0

(5,375)

(63)

(0)

(3,316)

(43)

(0)

(2,472)

(3,431)

(0)

50 Figure B4. Delaware detailed map DOVer 75*

Delaware - 90 m Offshore Wind Speed 74*

Contours Water Depth (Meters)

Distance from Sh0f8 (Nautlcal Miles)

The offshore wind resoorce data was originally estimated by AWS Truewind l

_~.~ __ ~~~:r------~f~j~f-jL_--71-~~1~;'i7---r-l as part of an onshore wtnd mapping project. These data have been Interpolated to 90 m and extrapolated 39-to 50 nautical miles by NREL.

L,----~---I 3... 1 75*

~i-~~-=~~O~========~~ ________ ~~~======~OO ~~ers 10 10 20 30 Nautical Miles 74*

Wind Speed at 90 m mls mph 11.5 -12.0 11.0-11.5 10.5 -11.0 10.0 *1 0.5 9.5*10.0 9.0 - 9.5 8.5-9.0 8.0 - 8.5 7.5 - 8.0 7.0- 7.5 6.5-7.0 6.0 - 6.5 0.0 - 6.0 25.7 - 26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3*22.4 20.1-21.3 19.0*20.1 17.9 -19.0 16.8*17.9 15.7 -16.8 14.5 -15.7 13.4 -14.5 0.0 -13.4 U.S. Department of Energy National Renewable Energy Laboratory

51 Table B5. Georgia offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 547 0

0 2,162 0

0 1,111 0

0 (2,737)

(0)

(0)

(10,811)

(0)

(0)

(5,553)

(0)

(0) 7.5 - 8.0 85 0

0 530 0

0 5,204 1,922 0

(426)

(0)

(0)

(2,648)

(0)

(0)

(26,021)

(9,610)

(0) 8.0 - 8.5 0

0 0

0 0

0 4

520 0

(0)

(0)

(0)

(0)

(0)

(0)

(19)

(2,598)

(0) 8.5 - 9.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 633 0

0 2,692 0

0 6,319 2,442 0

(3,164)

(0)

(0)

(13,459)

(0)

(0)

(31,594)

(12,208)

(0)

52 Figure B5. Georgia detailed map Georgia - 90 m Offshore Wind Speed 8, '

80' Savannah 32' f--------'r---T-~qf'__,o"""~

f.c---.....(-==--------------fi 32'

,/

>*OJ........... * ** *, *****

3,' ~"",J...::""

Wind Speed at 90 m mi.

11.5 -12.0 11.0 - 11.5 10.5 -1 1.0 10.0 - 10.5 9.5 - 10.0 9.0 -

9.5 8.5 - 9.0 8.0 -

8.5 7.5 - 8.0 7.0 -

7.5 6.5 -

7.0 6.0 -

6.5 0.0 - 6.0 mph 25.7 *26.8 24.S -25.7 23.5 -24.6 22.4 -23.5 21.3*22.4 20.1*21.3 19.0 *20.1 17.9 -19.0 16.8*17.9 15.7 -16.8 14.5 -1 5.7 13.4 - 14.5 0.0 - 13.4 4--------;-~-M'Y-"<--f------ii 3,'

8, '

Contours

-- Water Depth (Meters)

Distance from ShOl8 (Nautical Milas)

The annual wind speed estimates for this map were produced by AWS Truewind using their Mesomap system and historical weather data.

'~

o ~~~=i-';;'

O _...:20~=o=,30;:.._.;:40~,=,o:;50 KIome1~

';;.0 ~~~~0~===~

1O;... ___ :20 Nautical Mites U.S. Department of Energy National Renewable Energy Laboratory

53 Table B6. Hawaii offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 111 97 2,631 0

43 2,213 44 117 13,615 (557)

(486)

(13,157)

(0)

(213)

(11,067)

(222)

(584)

(68,077) 7.5 - 8.0 66 107 2,404 0

145 5,052 7

251 34,268 (328)

(535)

(12,020)

(0)

(725)

(25,258)

(34)

(1,254)

(171,338) 8.0 - 8.5 92 115 2,364 0

15 4,756 0

0 25,700 (461)

(574)

(11,822)

(0)

(75)

(23,778)

(1)

(1)

(128,498) 8.5 - 9.0 66 67 2,105 0

0 2,626 0

0 9,050 (328)

(335)

(10,526)

(0)

(0)

(13,128)

(0)

(0)

(45,250) 9.0 - 9.5 26 39 996 0

0 1,853 0

0 4,866 (129)

(195)

(4,978)

(0)

(0)

(9,265)

(0)

(0)

(24,328) 9.5 - 10.0 22 40 666 0

0 1,065 0

0 4,927 (110)

(199)

(3,330)

(0)

(0)

(5,324)

(0)

(0)

(24,634)

>10.0 26 71 1,344 0

0 2,028 0

0 1,384 (132)

(353)

(6,720)

(0)

(0)

(10,138)

(0)

(0)

(6,918)

Total >7.0 409 535 12,511 0

203 19,592 51 368 93,808 (2,045)

(2,677)

(62,553)

(0)

(1,013)

(97,958)

(257)

(1,839)

(469,041)

54 Figure B6. Hawaii detailed map

55 Table B7. Illinois offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 92 0

0 0

0 0

0 0

0 (458)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 165 0

0 0

0 0

0 1

0 (823)

(0)

(0)

(0)

(1)

(0)

(0)

(6)

(0) 8.0 - 8.5 244 1

0 830 512 141 7

426 1,683 (1,221)

(5)

(0)

(4,152)

(2,561)

(704)

(35)

(2,130)

(8,414) 8.5 - 9.0 0

0 0

13 77 0

0 0

0 (0)

(0)

(0)

(67)

(383)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 500 1

0 844 589 141 7

427 1,683 (2,502)

(5)

(0)

(4,219)

(2,944)

(704)

(35)

(2,137)

(8,414)

56 Figure B7. Illinois detailed map IIlinios - 90 m Offshore Wind Speed 87" 3 rwnl 12 nml BOm 42" f--------\\.t---

-'r


=::"--~---H 42 "

Wind Speed at 90 m mI' 11.5-12.0 11.0-11.5 10.5-11.0 10.0 - 10.5 9.5 - 10.0 9.0 - 9.5 8.5-9.0 8.0- 8.5 7.5-8.0 7.0- 7.5 6.5-7.0 6.0- 6.5 0.0- 6.0 mph 25.7 -28.8 24.6 -25.7 23.5 - 24.6 22.4 -23.5 21.3 -22.4 20.1-21.3 19.0-20.1 17.9-19.0 16.8 -17.9 15.7 -16.8 14.5 - 15.7 13.4 -14.5 0.0 - 13.4 87" Contours

-- Water Depth (Meters)

~istance from Shore (Nautical Miles)

'O::..=_~_O~===~

'O:... ___.::20 KJometen r-__________

-=~~~~O~===~---~1,O ~~~I~IM The annual wind speed estimates for this map were produced by AWSTruewind using their Mesomap system and historical weather data.

E!.

U.S. Department of Energy National Renewable Energy Laboratory

57 Table B8. Indiana offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 82 0

0 0

0 0

0 0

0 (410)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 154 0

0 63 0

0 0

0 0

(769)

(0)

(0)

(313)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 101 0

0 184 0

0 0

0 0

(507)

(0)

(0)

(920)

(0)

(0)

(0)

(0)

(0) 8.5 - 9.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 337 0

0 247 0

0 0

0 0

(1,687)

(0)

(0)

(1,233)

(0)

(0)

(0)

(0)

(0)

58 Figure B8. Indiana detailed map Wind Speed at 90 m mi.

11.5*12.0 11.0-11.5 10.5 - 11.0 10.0 - 10.5 9.5 -10.0 9.0 - 9.5 8.5 - 9.0 8.0 - 8.5 7.5 - 8.0 7.0-7.5 6.5 -

7.0 6.0 - 6.5 0.0 - 6.0 mph 25.7 - 26.8 24.6 - 25.7 23.5 -24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0-20.1 17.9-19.0 18.8 - 17.9 15.7 -16.8 14.5 -15.7 13.4 -14.5 0.0 - 13.4 Indiana - 90 m Offshore Wind Speed Ga",

  • The annual wind speed estimates for this map were produced by AWSTruewlnd using their Mesomap system and historical weather data.

Contours Water Depth (Meters)

Distance from Shore (Nautical Miles) 87" Michigan City 87*

~~==~

4~=-... -=~'O __ ~1.2 ~~

2 3

5 6 Nautical Miles U.S. Department of Energy National Renewable Energy Laboratory

59 Table B9. Louisiana offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 7,760 29 0

7,825 643 1,460 11,164 5,479 13,682 (38,798)

(143)

(0)

(39,126)

(3,217)

(7,302)

(55,819)

(27,396)

(68,412) 7.5 - 8.0 155 0

0 1,625 0

0 8,170 2,229 2,854 (776)

(0)

(0)

(8,123)

(0)

(0)

(40,850)

(11,143)

(14,271) 8.0 - 8.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 8.5 - 9.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 7,915 29 0

9,450 643 1,460 19,334 7,708 16,537 (39,574)

(143)

(0)

(47,249)

(3,217)

(7,302)

(96,669)

(38,539)

(82,683)

60 Figure B9. Louisiana detailed map Louisiana 90 m Offshore Wind Speed 94" 93" 92" 3 nmi 12nml ---_

~" ~~----------~~~~

mI, 11.5-12.0 11.0-11.5 10.5 - 11.0 10.0 - 10.5 9.5 - 10.0 9.0 - 9.5 8.5-9.0 8.0 - 8.5 7.5-8.0 7.0- 7.5 6.5-7.0 6.0- 6.5 0.0- 6.0 mph 25.7 - 26.8 24.S -25.7 23.5 -24.6 22.4 - 23.5 21.3*22.4 20.1-21.3 19.0-20.1 17.9 - 19.0 16.8 - 17.9 15.7 - 16.8 14.5 - 15.7 13.4 - 14.5 0.0 - 13.4 92" The annual wind speed estimates for this map were produced by AWSTruewind using their Mesomap system and historical weather data.

Contours

-- Water Depth (MeI9fS)

Distance from Shore (Nautical Miles) 9' "

90" 9'"

90"

~"

89" 20 2O;..~~.;O~==~

2O;..._....;

40 Nautical Miles N _L U.S. Department of Energy National Renewable Energy Laboratory

61 Table B10. Maine offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 787 91 12 8

5 4

0 0

0 (3,935)

(456)

(59)

(39)

(24)

(18)

(0)

(0)

(0) 7.5 - 8.0 797 285 19 7

20 14 0

0 0

(3,986)

(1,427)

(97)

(33)

(98)

(70)

(0)

(0)

(0) 8.0 - 8.5 777 441 74 63 386 235 0

0 0

(3,885)

(2,204)

(371)

(317)

(1,928)

(1,173)

(0)

(0)

(0) 8.5 - 9.0 513 614 158 18 219 1,402 0

0 407 (2,567)

(3,070)

(788)

(91)

(1,095)

(7,010)

(0)

(0)

(2,034) 9.0 - 9.5 142 390 309 26 469 3,504 0

58 3,531 (711)

(1,950)

(1,546)

(129)

(2,345)

(17,520)

(0)

(289)

(17,655) 9.5 - 10.0 6

25 42 1

38 1,460 0

7 13,906 (28)

(124)

(211)

(5)

(191)

(7,299)

(0)

(37)

(69,528)

>10.0 0

0 0

0 0

42 0

0 0

(0)

(0)

(0)

(0)

(0)

(208)

(0)

(0)

(0)

Total >7.0 3,022 1,846 615 123 1,136 6,659 0

65 17,843 (15,111)

(9,231)

(3,073)

(615)

(5,682)

(33,297)

(0)

(326)

(89,217)

62 Figure B10. Maine detailed map 7'"

70" 69" 68" 67" r-~--~--~--'-----~~~--~=-~----'-~~---'

45" Maine 90 m Offshore Wind Speed Contours 44"

---+--j 44" Water Depth (Meters)

Distance from Shore (Nautical Miles) 43" 70" 69" 2O-=~-===>20~_4()

-===60;;.._

ao===='i100 Kilometen 2O~=~~.:O~===~20:... __....:40 Nautical Mles U.S. Department of Energy National Renewable Energy Laboratory The annual wind speed estimates for this map were produced by AWS Truewlnd using their Mesomap system and historical weather data.

Wind Speed at 90 m m/s mph

~~ __ +--______ -+_--j 43" 11.S-12.0 11.0 *11.5 10.5 -11.0 10.0 - 10.5 9.5 - 10.0 9.0 - 9.5 8.5 -

9.0 8.0 - 8.5 7.5 -

8.0 7.0 -

7.5 6.5 -

7.0 6.0 -

6.5 0.0 -

6.0 25.7 -26.8 24.S -25.7 23.5 -24.6 22.4 -23.5 21.3 - 22.4 20.1 -21.3 19.0-20.1 17.9 -19.0 16.8 - 17.9 15.7 -18.8 14.5 -15.7 13.4 - 14.5 0.0 - 13.4 68" 67"

63 Table B11. Maryland offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 2,175 17 0

0 0

0 0

0 0

(10,877)

(83)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 1,923 14 0

10 0

0 0

0 0

(9,613)

(70)

(0)

(49)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 163 0

0 924 0

0 435 17 0

(817)

(0)

(0)

(4,620)

(0)

(0)

(2,177)

(86)

(0) 8.5 - 9.0 0

0 0

0 0

0 531 3,211 1,336 (0)

(0)

(0)

(0)

(0)

(0)

(2,656)

(16,053)

(6,681) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 4,261 31 0

934 0

0 967 3,228 1,336 (21,306)

(153)

(0)

(4,670)

(0)

(0)

(4,833)

(16,139)

(6,681)

64 Figure B11. Maryland detailed map Maryland - 90 m Offshore Wind Speed n*

76*

75*

~

'.-...... -'~

  • '~~-~7::~*

38* I-+------'~

n*

76*

75*

w~~~O~==~w~

__ ~~~==~OO~

__ ~

OO~==~

100 ~~~

10 10 20 30

<W 50 Nat*:aI MII8I 74*

74*

Wind Speed at 90 m mi.

11.5 -12.0 11.0*11.5 10.5 -11.0 10.0 -10.5 9.5 - 10.0 9.0-9.5 8.5-9.0 8.0- 8.5 7.5 - 8.0 7.0-7.5 6.5-7.0 6.0 - 6.5 0.0 - 6.0 mph 25.7 - 26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0-20.1 17.9-19.0 16.8 -17.9 15.7 -16.8 14.5-15.7 13.4 -14.5 0.0 - 13.4 The offshore wind resource data was originally estimated by AWS Truewind as part of an onshore wind mapping project. These data have been Interpolated to 90 m and extrapolated to 50 nautical miles by NREL.

Contours Water Depth (Meters)

Distance from Shore (Nautical Miles)

U.S. Department of Energy National Renewable Energy Laboratory

65 Table B12. Massachusetts offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 202 0

0 0

0 0

0 0

0 (1,008)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 521 5

0 0

0 0

0 0

0 (2,607)

(23)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 927 327 29 78 152 126 0

0 0

(4,637)

(1,636)

(143)

(391)

(760)

(628)

(0)

(0)

(0) 8.5 - 9.0 1,508 378 13 315 355 812 11 24 190 (7,541)

(1,890)

(63)

(1,575)

(1,773)

(4,061)

(57)

(118)

(952) 9.0 - 9.5 1,137 323 20 2,697 1,419 1,007 1,690 5,052 7,007 (5,685)

(1,613)

(100)

(13,484)

(7,093)

(5,033)

(8,449)

(25,259)

(35,037) 9.5 - 10.0 2

0 0

9 119 0

472 3,460 9,613 (10)

(0)

(0)

(43)

(596)

(0)

(2,361)

(17,298)

(48,063)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 4,298 1,033 61 3,099 2,044 1,944 2,173 8,535 16,810 (21,489)

(5,163)

(307)

(15,493)

(10,222)

(9,721)

(10,867)

(42,674)

(84,051)

66 Figure B12. Massachusetts detailed map 7'*

70*

69*

42*

4'*

~.~~=-~O=====~~ ____ =~~==~~~

__ ~OO~==~

100 ~en 20 0

20

-40 Nautical Mles Massach usetts 90 m Offshore Wind Speed Contours Water Depth (Meters)

Distance from Shore (Nautical Miles)

The annual wind speed estimates for this map were produced by AWSTruewind using their Mesomap system and historical weather data.

Wind Speed at 90 m mi.

11.5-12.0 11.0-11.5 10.5 -11.0 10.0 -10.5 9.5-10.0 9.0-9.5 8.5-9.0 8.0-8.5 7.5 - 8.0 7.0-7.5 6.5-7.0 6.0- 6.5 0.0 - 6.0 mph 25.7 - 26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0 - 20.1 17.9 -19.0 16.8 - 17.9 15.7 - 16.8 14.5 - 15.7 13.4 -14.5 0.0 - 13.4 U.S. Department of Energy National Renewable Energy laboratory

67 Table B13. Michigan offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 3,411 331 244 143 50 268 1

0 12 (17,057)

(1,653)

(1,218)

(713)

(249)

(1,340)

(6)

(0)

(61) 7.5 - 8.0 4,633 1,258 635 3,069 2,916 2,991 14 108 2,448 (23,163)

(6,291)

(3,177)

(15,345)

(14,582)

(14,955)

(71)

(542)

(12,242) 8.0 - 8.5 2,588 1,253 769 2,771 5,890 9,412 31 876 7,496 (12,940)

(6,267)

(3,845)

(13,853)

(29,448)

(47,059)

(155)

(4,381)

(37,482) 8.5 - 9.0 139 156 397 145 551 8,581 118 1,384 22,834 (693)

(781)

(1,983)

(726)

(2,753)

(42,904)

(592)

(6,920)

(114,172) 9.0 - 9.5 0

0 0

0 0

70 115 250 8,285 (0)

(0)

(0)

(0)

(0)

(350)

(573)

(1,248)

(41,423) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 10,771 2,998 2,044 6,127 9,407 21,322 279 2,618 41,076 (53,854)

(14,991)

(10,222)

(30,636)

(47,033)

(106,608)

(1,397)

(13,090)

(205,379)

68 Figure B13. Michigan detailed map 48' 48' Michigan - 90 m Offshore Wind Speed so*

88' 86' 84' 82' The annual wind speed estimates t--jd~~~~~~~;:""~~~~-\\>l~;=~"7~--1 for this map were produced by I

AWSTruewind using their Mesomap Wind Speed at 90 m m/s mph 11.5-12.0 11.0 - 11.5 10.5 -1 1.0 10.0 *10.5 9.5 - 10.0 9.0- 9.5 8.5 - 9.0 8.0- 8.5 7.5 - 8.0 7.0-7.5 6.5 -

7.0 6.0-6.5 0.0-6.0 25.7 - 26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1 - 21.3 19.0 - 20.1 17.9 -19.0 16.8 -17.9 15.7 -16.8 14.5 -15.7 13.4 - 14.5 0.0 - 13.4 88' Contours Water Depth (Meters)

Distance from Shore (Nautical Miles) sys1em and historical weather data.

46' 86' 84' 5O~-C~O=:o:=o"i50~_~'OO~=::='i50~~200

KHome1""

20 20 40 60 80 100 Nautical Miles U.S. Department of Energy National Renewable Energy Laboratory

69 Table B14. Minnesota offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 5

44 273 0

32 1,718 0

0 1,031 (25)

(218)

(1,363)

(0)

(158)

(8,590)

(0)

(0)

(5,155) 7.5 - 8.0 0

0 13 0

0 61 0

0 921 (0)

(0)

(64)

(0)

(0)

(304)

(0)

(0)

(4,603) 8.0 - 8.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 8.5 - 9.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 5

44 285 0

32 1,779 0

0 1,952 (25)

(218)

(1,427)

(0)

(158)

(8,895)

(0)

(0)

(9,759)

70 Figure B14. Minnesota detailed tables and maps Minnesota - 90 m Offshore Wind Speed 47" 2.

0-=~~_O~=====5~

~=======OO~ ____...

OO ~ommetS 1~O-=_~",O======,,1O ______

.;;~,,======:lO _____ ~

40 Nautical Miles N

U.S. Department of Energy National Renewable Energy laboratory The annual wind speed estimates for this map were produced by AWSTrueYt'ind using their Mesomap sys1em and historical weather data.

Contours Water Depth (Meters)

Distance from Shore (Nautical Miles)

Wind Speed at 90 m m1s mph 11.5-12.0 11.0-11.5 10.5-11.0 10.0 -10.5 9.5-10.0 9.0 - 9.5 8.5 - 9.0 8.0 - 8.5 7.5 - 8.0 7.0 -

7.5 6.5 - 7.0 6.0 - 6.5 0.0 - 6.0 25.7 - 26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0-20.1 17.9-19.0 16.8 - 17.9 15.7 - 16.8 14.5 - 15.7 13.4 -14.5 0.0 -13.4

71 Table B15. New Hampshire offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 19 0

0 0

0 0

0 0

0 (93)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 46 0

0 0

0 0

0 0

0 (229)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 45 30 0

7 76 14 0

0 0

(223)

(148)

(0)

(34)

(378)

(70)

(0)

(0)

(0) 8.5 - 9.0 0

8 7

0 12 256 0

10 42 (0)

(40)

(36)

(0)

(62)

(1,279)

(0)

(51)

(211) 9.0 - 9.5 0

0 0

0 0

0 0

35 66 (0)

(0)

(0)

(0)

(0)

(0)

(0)

(176)

(332) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 109 38 7

7 88 270 0

45 109 (545)

(188)

(36)

(35)

(439)

(1,348)

(0)

(227)

(543)

72 Figure B15. New Hampshire detailed map New Hampshire - 90 m Offshore Wind Speed 43' r------~ t--30-;;;:--=-:;t..~~I-----------~------ 43' mls mph 11.5*12.0 11.0-11.5 10.5 - 11.0 10.0 - 10.5 9.5 -10.0 9.0 - 9.5 8.5 - 9.0 8.0 - 8.5 7.5 - 8.0 7.0-7.5 6.5 -

7.0 6.0 - 6.5 0.0 - 6.0 25.7 - 26.8 24.6 - 25.7 23.5 -24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0-20.1 17.9-19.0 18.8 - 17.9 15.7 -16.8 14.5 -15.7 13.4 -14.5 0.0 - 13.4 80m Contours Water Depth (Meters)

Distance from Shore (Nautical Miles)

The annual wind speed estimates for this map were produced by AWSTnJewind using their Mesomap system and historical weather data.

~

80m 10 15 KIometel1J

~~~~==~2 __

"':==o=l~_~8 Nautical Miles HEL U.S. Department of Energy National ReneYi8b1e Energy Laboratory

73 Table B16. New Jersey offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 520 0

0 8

0 0

0 0

0 (2,601)

(0)

(0)

(41)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 960 0

0 519 28 1

0 0

0 (4,802)

(0)

(0)

(2,593)

(140)

(4)

(0)

(0)

(0) 8.0 - 8.5 777 0

0 2,765 127 3

899 372 22 (3,885)

(0)

(0)

(13,824)

(636)

(16)

(4,497)

(1,862)

(108) 8.5 - 9.0 13 0

0 215 0

0 2,020 10,382 304 (66)

(0)

(0)

(1,074)

(0)

(0)

(10,098)

(51,912)

(1,519) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 2,271 0

0 3,506 155 4

2,919 10,755 325 (11,353)

(0)

(0)

(17,532)

(775)

(20)

(14,595)

(53,774)

(1,627)

74 Figure B16. New Jersey detailed map New Jersey - 90 m Offshore Wind Speed 75'

,.. :' \\... -..

. -~

Trwnton 40'

.. **,**""",3" 39' Contours Water Depth (Meters)

__ Distance from Shore (Nautical Miles)

W ind Speed at 90 m mi.

11.5-12.0 11.0 - 11.5 10.5 - 11.0 10.0 -10.5 9.5-10.0 9.0 - 9.5 8.5 - 9.0 8.0 - 8.5 7.5 -

8.0 7.0 -

7.5 6.5 - 7.0 6.0 - 6.5 0.0 - 6.0 mph 25.7 -26.8 24.6 -25.7 23.5 -24.S 22.4 -23.5 21.3 -22.4 20.1 -21.3 19.0-20.1 17.9 -19.0 16.8 -17.9 15.7 - 16.8 14.5 -15.7 13.4 -14.5 0.0 - 13.4 74' The offshore wind resource data was originally estimated by AWS Truewind as part of an onshore wind mapping project. These daia have been Interpolated to 90 m and extrapolated to 50 nautical miles by NREL.

20 20 40 60 80 KJometors 1O:.c~~O~=~'O:..._...::20~=~30:..._..;;-40 Nautical Miles U.S. Department of Energy National Renewable Energy Laboratory

75 Table B17. New York offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 1,048 54 0

3 0

0 0

0 0

(5,239)

(271)

(0)

(14)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 1,983 355 12 473 609 867 0

0 60 (9,915)

(1,774)

(58)

(2,363)

(3,045)

(4,334)

(0)

(0)

(300) 8.0 - 8.5 1,329 603 196 376 536 3,122 42 13 2,107 (6,646)

(3,015)

(982)

(1,878)

(2,679)

(15,610)

(211)

(63)

(10,537) 8.5 - 9.0 535 111 1

1,043 94 0

261 728 104 (2,675)

(553)

(3)

(5,213)

(469)

(0)

(1,307)

(3,639)

(522) 9.0 - 9.5 5

0 0

392 1,408 0

6 4,926 716 (27)

(0)

(0)

(1,959)

(7,038)

(0)

(32)

(24,631)

(3,580) 9.5 - 10.0 0

0 0

0 0

0 0

1,818 3,505 (0)

(0)

(0)

(0)

(0)

(0)

(0)

(9,088)

(17,524)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 4,901 1,122 209 2,286 2,646 3,989 310 7,484 6,493 (24,503)

(5,612)

(1,043)

(11,428)

(13,230)

(19,944)

(1,550)

(37,420)

(32,463)

76 Figure B17. New York detailed map 79*

78*

77*

76*

44*

\\,.--'.-_..,;.)._-.....

=;'

S~cuse _

..... \\

... l.. *--' __ '

43*

-.-~\\

,)

'-""~---

~:

\\."---""

'I

.j,_!.-----..

~----:,-~.

'\\-- -.:

~--

~-----~-::... T-:

The annual wind speed estimates for the Great Lakes section of this map were produced by AWS Truewind L<::.,L------'"'--l using their Mesomap system and historical weather Contours

-- Water Depth (Meters)

Distance from Shore (Nautical Miles)

HE!.

data. The offshore wind resource data for the Atlantic Coast section of this map was originally estimated by AWS Truewind as part of an onshore wind mapping project. These data have been Interpolated to 90 m and extrapolated to 50 nautical miles by NREL.

U.S. Department of Energy National Renewable Energy Laboratcxy 4'*

40*

43*

New York 90 m Offshore Wind Speed Wind Speed at 90 m mi.

11.5 -12.0 11.0 - 11.5 10.5 -11.0 10.0 -10.5 9.5 - 10.0 9.0- 9.5 8.5-9.0 8.0- 8.5 7.5-8.0 7.0- 7.5 6.5-7.0 6.0- 6.5 0.0- 6.0 mph 25.7*26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1 - 21.3 19.0-20.1 17.9 -19.0 16.8 -17.9 15.7 -16.8 14.5 -15.7 13.4 -14.5 0.0 - 13.4

77 Table B18. North Carolina offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 1,847 0

0 0

0 0

0 0

0 (9,237)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 3,002 0

0 1,096 0

0 0

0 0

(15,010)

(0)

(0)

(5,481)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 3,920 0

0 4,654 0

0 4,035 747 299 (19,600)

(1)

(0)

(23,269)

(0)

(0)

(20,174)

(3,733)

(1,496) 8.5 - 9.0 105 0

0 2,964 261 9

6,382 14,520 15,633 (525)

(0)

(0)

(14,821)

(1,307)

(45)

(31,912)

(72,598)

(78,167) 9.0 - 9.5 0

0 0

0 0

0 0

16 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(80)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 8,874 0

0 8,714 261 9

10,417 15,282 15,933 (44,372)

(1)

(0)

(43,570)

(1,307)

(45)

(52,087)

(76,411)

(79,663)

78 Figure B18. North Carolina detailed map North Carolina - 90 m Offshore Wind Speed 78*

~======,----,---~~

Contours

  • I<T" Water Depth (Meters)

Distance from ShOfEl (Nautical Miles) r--**... *_'**..

78*

2O~.aCo=§'20;..._

40=;;i60_...;80

<'=;;;=

'00;::.._

12=O~

140 KIometen; 2O_~~_O<====20 ___..;40-===="60 Nautical Miles N

U.S. Department of Energy National Renewable Energy laboratory 76*

76*

75*

The offshore wind resource data was originally estimated by AWS Truewlnd as part of an onshore wind mapping project. These data have been Interpolated to 90 m and extrapolated to 50 nautical miles by NREL.

Wind Speed at 90 m mi.

11.5 - 12.0 11.0 - 11.5 10.5 -1 1.0 10.0 - 10.5 9.5 -10.0 9.0 - 9.5 8.5 - 9.0 8.0 -

8.5 7.5 - 8.0 7.0 -

7.5 6.5 - 7.0 6.0 - 6.5 0.0 -

6.0 mph 25.7 - 26.8 24.6 - 25.7 23.S - 24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0-20.1 17.9 - 19.0 16.8 -17.9 15.7 -16.8 14.5 - 15.7 13.4 -14.5 0.0 - 13.4

79 Table B19. Ohio offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 341 0

0 0

0 0

0 0

0 (1,705)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 1,107 0

0 1,960 0

0 0

0 0

(5,534)

(0)

(0)

(9,799)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 565 0

0 2,193 0

0 3,071 0

0 (2,826)

(0)

(0)

(10,965)

(0)

(0)

(15,356)

(0)

(0) 8.5 - 9.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 2,013 0

0 4,153 0

0 3,071 0

0 (10,065)

(0)

(0)

(20,765)

(0)

(0)

(15,356)

(0)

(0)

80 Figure B19. Ohio detailed map 83*

"----r--

~-.-,

\\ :.-.-

83*

U.S. Department of Energy National Renewable Energy Laboratory Ohio - 90 m Offshore Wind Speed 82*

82*

y- -.--. ~.-... -.....

\\

\\

The annual wind speed estimates for this map were produced by AWSTruewlnd using their Mesomap system and historical -weather data.

8'*

Contours Water Depth (Meters)

Distance from Shore (Nautical Miles)

Wind Speed at 90 m mi.

11.5 - 12.0 11.0-11.5 10.5 - 11.0 10.0 -10.5 9.5 -10.0 9.0 - 9.5 8.5 - 9.0 8.0 - 8.5 7.5 - 8.0 7.0 -

7.5 6.5 -

7.0 6.0 -

6.5 0.0 -

6.0 mph 25.7 - 26.8 24.6*25.7 23.5 -24.6 22.4 -23.5 21.3*22.4 20.1*21.3 19.0 *20.1 17.9 -19.0 16.8

  • 17.9 15.7
  • 16.8 14.5 -15.7 13.4 - 14.5 0.0 - 13.4

81 Table B20. Oregon offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 356 21 0

1 9

1 0

0 0

(1,779)

(103)

(0)

(4)

(46)

(6)

(0)

(0)

(0) 7.5 - 8.0 523 319 38 46 232 335 0

0 0

(2,615)

(1,596)

(188)

(232)

(1,159)

(1,675)

(0)

(0)

(0) 8.0 - 8.5 198 277 7

19 596 2,558 0

0 4,989 (991)

(1,385)

(33)

(95)

(2,978)

(12,792)

(0)

(0)

(24,947) 8.5 - 9.0 64 99 1

0 108 1,967 0

46 11,640 (320)

(494)

(3)

(0)

(540)

(9,836)

(0)

(228)

(58,201) 9.0 - 9.5 64 55 39 0

33 615 0

0 6,588 (321)

(277)

(193)

(0)

(163)

(3,074)

(0)

(0)

(32,941) 9.5 - 10.0 47 80 15 0

34 635 0

0 5,255 (237)

(402)

(73)

(0)

(169)

(3,173)

(0)

(0)

(26,273)

>10.0 0

19 33 0

18 1,369 0

0 4,546 (1)

(97)

(166)

(0)

(91)

(6,843)

(0)

(0)

(22,730)

Total >7.0 1,253 871 131 66 1,029 7,480 0

46 33,019 (6,264)

(4,354)

(656)

(332)

(5,146)

(37,399)

(0)

(228)

(165,093)

82 Figure B20. Oregon detailed map U.S. Department of Energy National Renewable Energy laboratory

83 Table B21. Pennsylvania offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 34 0

0 0

0 0

0 0

0 (171)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 113 0

0 53 44 0

0 0

0 (567)

(0)

(0)

(266)

(221)

(0)

(0)

(0)

(0) 8.0 - 8.5 276 1

0 751 358 0

223 70 0

(1,381)

(4)

(0)

(3,754)

(1,790)

(0)

(1,114)

(351)

(0) 8.5 - 9.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 424 1

0 804 402 0

223 70 0

(2,119)

(4)

(0)

(4,020)

(2,012)

(0)

(1,114)

(351)

(0)

84 Figure B21. Pennsylvania detailed map Pennsylvania - 90 m Offshore Wind Speed Wind Speed at 90 m mi.

11.5-12.0 11.0 - 11.5 10.5-11.0 10.0 -10.5 9.5 - 10.0 9.0 - 9.5 8.5 - 9.0 8.0 - 8.5 7.5 - 8.0 7.0 - 7.5 6.5-7.0 6.0 -

6.5 0.0 - 6.0 mph 25.7 -26.8 24.6 - 25.7 23.5 -24.6 22.4*23.5 21.3 - 22.4 20.1-21.3 19.0-20.1 17.9 -19.0 16.8 - 17.9 15.7 -16.8 14.5 -15.7 13.4 -14.5 0.0-13.4 CANADA Contours Water Depth (Meters)

Distance from Shore (Nautical Miles)

The annual wind speed estimates for this map were produced by AWSTruewind using their Mesomap system and historical weather data.

so*

N _L U.S. Department of Energy National Renewable Energy Laboratory

85 Table B22. Rhode Island offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 216 8

0 0

0 0

0 0

0 (1,082)

(40)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 123 3

0 0

0 0

0 0

0 (616)

(14)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 140 40 0

35 69 0

0 0

0 (700)

(199)

(0)

(173)

(346)

(0)

(0)

(0)

(0) 8.5 - 9.0 120 93 0

184 274 0

0 0

0 (602)

(465)

(0)

(918)

(1,371)

(0)

(0)

(0)

(0) 9.0 - 9.5 54 18 0

176 783 0

0 430 1

(269)

(88)

(0)

(880)

(3,914)

(0)

(0)

(2,151)

(6) 9.5 - 10.0 0

0 0

0 6

0 0

967 1,387 (0)

(0)

(0)

(0)

(29)

(0)

(0)

(4,836)

(6,934)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 653 161 0

394 1,132 0

0 1,397 1,388 (3,267)

(806)

(0)

(1,970)

(5,660)

(0)

(0)

(6,987)

(6,940)

86 Figure B22. Rhode Island detailed map Rhode Island - 90 m Offshore Wind Speed Contours Water Depth (Meters)

Distance from ShOl8 (Nautical Miles)

The offshore wind resource data was originally estimated by AWS Truewind as part of an onshore wind mapping project. These data have been IntElfPOlated to 90 m and extrapolated to 50 nautical miles by NREL.

Wind Speed at 90 m mi.

11.5 -12.0 11.0 -11.5 10.5-11.0 10.0-10.5 9.5 - 10.0 9.0- 9.5 8.5-9.0 B.O-8.5 7.5-8.0 7.0- 7.5 6.5-7.0 6.0- 6.5 0.0- 6.0 mph 25.7 - 26.8 24.6 -25.7 23.5 - 24.6 22.4 - 23.5 21.3 -22.4 20.1 - 21.3 19.0-20.1 17.9 -19.0 16.8 -17.9 15.7-16.8 14.5-15.7 13.4-14.5 0.0 - 13.4 U.S. Department of Energy National Renewable Energy Laboratory 71*

71

  • 10 10 20 30 40 50 60 KIometenl
.c~~==C~-~'::'O~='C:'=:;;-20~~==25==~::'~Na~uticai Miles

87 Table B23. South Carolina offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 848 0

0 608 0

0 0

0 0

(4,241)

(0)

(0)

(3,042)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 594 0

0 3,054 0

0 4,268 287 0

(2,968)

(0)

(0)

(15,269)

(0)

(0)

(21,338)

(1,435)

(0) 8.0 - 8.5 23 0

0 1,609 0

0 4,151 3,926 674 (115)

(0)

(0)

(8,047)

(0)

(0)

(20,757)

(19,628)

(3,372) 8.5 - 9.0 0

0 0

0 0

0 2,027 3,110 870 (0)

(0)

(0)

(0)

(0)

(0)

(10,135)

(15,548)

(4,349) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 1,465 0

0 5,272 0

0 10,446 7,322 1,544 (7,323)

(0)

(0)

(26,358)

(0)

(0)

(52,230)

(36,611)

(7,722)

88 Figure B23. South Carolina detailed map 33" 32" South Carolina - 90 m Offshore Wind Speed 80" 79"

~~~-F~--"------t~~=~--/~.,L--I--------j 32" Wind Speed at 90 m mi.

11.5 -12.0 11.0 -1 1.5 10.5 - 11.0 10.0 - 10.5 9.5-10.0 9.0- 9.5 8.5-9.0 B.O-8.5 7.5-8.0 7.0 - 7.5 B.S-7.0 B.O-6.5 0.0- 6.0 mph 25.7*26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0 -20.1 17.9 - 19.0 16.8 -17.9 15.7 -16.8 14.5 -15.7 13.4 -14.5 0.0 -13.4 80" 79" Contours

-- Water Depth (Meters)

Distance from Shore (Nautical Miles)

The offshore wind resource data was originally estimated by AWS Truewind as part of an onshore 'Hind mapping project. These data have been In ter~lated to 90 m and extrapolated to 50 nautical miles by NREL.

U.S. Department of Energy National Renewable Energy laboratory

89 Table B24. Texas offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 9*

9 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 1,786 0

0 96 0

0 137 0

0 (8,928)

(0)

(1)

(481)

(0)

(0)

(686)

(0)

(0) 7.5 - 8.0 9,046 0

0 1,165 0

0 8,045 6,175 392 (45,230)

(0)

(0)

(5,826)

(0)

(0)

(40,226)

(30,873)

(1,958) 8.0 - 8.5 5,929 125 0

742 137 0

584 4,443 4,597 (29,643)

(627)

(0)

(3,711)

(684)

(0)

(2,918)

(22,214)

(22,985) 8.5 - 9.0 3,798 601 0

43 945 0

0 3,211 3,675 (18,990)

(3,005)

(0)

(215)

(4,726)

(0)

(0)

(16,055)

(18,373) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 20,558 726 0

2,046 1,082 0

8,766 13,828 8,663 (102,791)

(3,632)

(1)

(10,232)

(5,410)

(0)

(43,829)

(69,142)

(43,316)

  • Federal waters begin at 9 nm for Texas

90 Figure B24. Texas detailed map 98' 97' 96' 95' 94'

~?Uston

~.,'

Texas

..../
'--h -.j

\\

---\\.

90 m Offshore

j.

.'\\'-

Wind Speed

...'~'"

/'<~~

."'~'"

29' i **.'

'(

29'

)'.

~.,

-.~-.-~--

i

\\..-.,

!, p

-.~

Cootours

-.,-;/

-- Water Depth (Meiers)

Distance from Shore (Nautical Miles)

';" "'1.,

28' "--. "',-

28' The annual wind speed estimates for this map were produced by AWS Truewind using their Mesomap system and historical weather data.

I(;

Wind Speed at 90 m 27' mi.

mph 27' 11.5 -1 2.0 25.7 - 26.8 11.0 - 11.5 24.6 -25.7 10.5 -11.0 23.5 -24.6 10.0 - 10.5 22.4 -23.5 r-----..

9.5 -10.0 21.3 - 22.4 9.0 - 9.'

20.1-21.3 8.5 - 9.*

19.0-20.1

~ "

8.0 - 8.'

17.9 -19.0 7.5 - 8.*

16.a -17.9 7.0 - 7.'

15.7 -16.8 28' 6.5 - 7.*

14.5 -15.7 6.0 - 6.'

13.4 -14.5 28' 0.0 - 6.*

0.0 - 13.4 98' 97' 96' 95' 94' 50 0

50 100 150 200 Kianot~

20 20 40 eo 80 100 Nautical Miles U.S. Department of Energy National Renewable Energy Laooratory

91 Table B25. Virginia offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 889 0

0 0

0 0

0 0

0 (4,446)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 7.5 - 8.0 3,606 15 0

37 0

0 0

0 0

(18,028)

(77)

(0)

(185)

(0)

(0)

(0)

(0)

(0) 8.0 - 8.5 1,136 2

0 2,986 0

0 2,356 69 0

(5,679)

(10)

(0)

(14,929)

(0)

(0)

(11,780)

(345)

(0) 8.5 - 9.0 0

0 0

24 0

0 2,030 4,840 900 (0)

(0)

(0)

(119)

(0)

(0)

(10,152)

(24,199)

(4,500) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 5,630 17 0

3,047 0

0 4,386 4,909 900 (28,152)

(87)

(0)

(15,233)

(0)

(0)

(21,932)

(24,544)

(4,500)

92 Figure B25. Virginia detailed map Virginia - 90 m Offshore Wind Speed 76" 2O

.~~~"===0520 ___ "'<,===;;eo;..._...;;ao K1omet~

';;.' ~~,;,,===,1O __

20===="

30;..._~

40 Nautical Miles U.S. Department of Energy National Renewable Energy Laboratory Contours Water Depth (Meters)

Distance from Shore (Nautical Miles) 75" The offshore wind resource data was originally estimated by AWS Truewind as part of an onshore wind mapping project. These data have been Interpolated to 90 m and extrapolated to SO nautical miles by NREL Wind Speed at 90 m m/s mph 11.5

  • 12.0 11.0*11.5 10,5 *11.0 10,0 *10.5 9.5 *10.0 9.0* 9.5 8.5* 9.0 8.0* 8.5 7.5* 8.0 7.0* 7.5 6.5* 7.0 6.0* 6.5 0.0
  • 6.0 25.7 *26.8 24.6 *25.7 23.5 *24.6 22.4 *23.5 21.3*22.4 20.1 *21.3 19.0 - 20.1 17.9 -19.0 16.8 -17.9 15.7 -16.8 14.5 -15.7 13.4 *14.5 0.0 - 13.4

93 Table B26. Washington offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 623 133 57 232 350 177 0

0 0

(3,115)

(667)

(286)

(1,159)

(1,751)

(884)

(0)

(0)

(1) 7.5 - 8.0 371 0

0 203 842 1,173 0

0 2,033 (1,853)

(0)

(0)

(1,015)

(4,208)

(5,865)

(0)

(0)

(10,166) 8.0 - 8.5 62 0

0 212 978 475 0

20 16,515 (308)

(0)

(0)

(1,059)

(4,889)

(2,375)

(0)

(98)

(82,574) 8.5 - 9.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 1,055 133 57 647 2,170 1,825 0

20 18,548 (5,276)

(667)

(286)

(3,233)

(10,849)

(9,124)

(0)

(98)

(92,741)

94 Figure B26. Washington detailed map 48" 47" Washington - 90 m Offshore Wind Speed 126" 125" 124" 123" rI~Th~.~O~ffimS:O:~::~~

  • ~~:~:~~~::~~d~~~a~was
o:n:gi:n:al~IY~~
ti;"m:~::ed;i~--~~~~~~J2~f;~;;::::::==::J 49" by AWS Truewind as part of an onshore wind mapping project. These data have been Interpolated to 90 m and extrapolated to 50 nautical miles by NREL 5On'"

n{f2 120V 1


j

--l(~,~~~~~~~~----~~~~--~.~.. ~~.-.,--------~ 47"

.. --:------~

'....... ~-

---,-~.....

r'"..... "...,......... j'-=------'-'---,

46" 5On'"

125" 2O

'::.o~~~==~20::.. ____ ;40~===-:60::.. __...:80 Kilometers

' ;;.O~~-====';;.O ____.;20-====30 ___....;40. Nautical Miles U.S. Department of Energy National Renewable Energy Laboratory Contours Water Depth (Meters)

Distance from Sh0f8 (Nautical Miles)

Wind Speed at 90 m mi.

11.5-12.0 11.0 - 11.5 10.5-11.0 10.0 -10.5 9.5 - 10.0 9.0 -

9.5 8.5 -

9.0 8.0 -

8.5 7.5 -

8.0 7.0 -

7.5 6,5 -

7.0 6.0 -

6.5 0.0 -

6.0 mph 25.7 -26.8 24.6 -25.7 23.5-24.6 22.4 - 23.5 21.3 - 22.4 20.1-21.3 19.0- 20.1 17.9-19.0 16.8-17.9 15.7-16.8 14.5-15.7 13.4 -14.5 0.0 - 13.4

95 Table B27. Wisconsin offshore wind resource by wind speed interval, water depth and distance from shore within 50 nm of shore.

Distance from Shore (nm) 0 - 3 3 - 12 12 - 50 Depth Category Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m)

Shallow (0 - 30 m)

Transitional (30 - 60m)

Deep

(> 60m) 90 m Wind Speed Interval (m/s)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW)

Area km2 (MW) 7.0 - 7.5 1,054 268 146 350 617 1,085 0

34 162 (5,269)

(1,341)

(729)

(1,749)

(3,083)

(5,425)

(0)

(171)

(810) 7.5 - 8.0 1,417 235 24 362 223 779 0

0 364 (7,086)

(1,177)

(119)

(1,808)

(1,115)

(3,896)

(0)

(0)

(1,821) 8.0 - 8.5 831 373 0

451 1,386 2,539 0

21 2,160 (4,153)

(1,863)

(0)

(2,257)

(6,930)

(12,695)

(0)

(107)

(10,800) 8.5 - 9.0 26 8

0 12 301 1,347 0

63 6,661 (128)

(41)

(0)

(58)

(1,504)

(6,737)

(0)

(314)

(33,305) 9.0 - 9.5 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0) 9.5 - 10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

>10.0 0

0 0

0 0

0 0

0 0

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

(0)

Total >7.0 3,327 884 169 1,175 2,526 5,751 0

118 9,347 (16,636)

(4,422)

(847)

(5,873)

(12,632)

(28,753)

(0)

(592)

(46,737)

96 Figure B27. Wisconsin detailed map 92" 47" Wisconsin - 90 m Offshore Wind Speed 9'"

90" 89" 88" 87" The annual wind speed estimates for thIs map were produced by 1:

f-.....,=~-c/;;
:::J:L--.JJ.:...b,.-=i AWSTruewind using their Mesomap system and hls10rical weather data.

r-~46~"~:J~::1:~-~=:'=

" =

" =

" ~'='='~ ____ -+~~~~_~ ____ ~ ___ ~ 46" Contours

-- WatEM'" Depth (Meters)

Distance from Shore (Nautical Miles)

~ ----------

r--***-----*-----~

45" r-t---~------1+'*~* ~

  • ~* ~**~*.~.~.. ~.l,_"I~~**~~,**-*-* _ci~*~**lc*~
    • ~*-
    • -'*-*~

' --~~~~~".~~~~1C+__l~ 45" Eau Cia ~

1____ _

---"-' ~'

-:------r - j

--L~-- ~~-;~,*-pOi

-_~ ____..t~.--

i

--i.. ____

Green ~

TO ** -:------"'--_. -: AiiPi8foo ~ ---:--~ --:

i-:

Ma~,I"'~r.~

44"

~----.

r" "

. F I

*..1..-

--~'::}------.. ----.. _--------:-----.,. ---


r-'------+ -

. j -----.

-L.: ---'Madison Milwaukee:

  • 43"

'- t+---\\--\\\\,rl 43"

-. --.. ~---- ---r------ ---:----1----- _.j.

an~Yille Wind Speed at 90 m mi.

11.5-12.0 11.0-11.5 10.5-11.0 10.0 -10.5 9.5 - 10.0 9.0 - 9.5 8.5 - 9.0 8.0 - 8.5 7.5 - 8.0 7.0 - 7.5 6.5 - 7.0 6.0 - 6.5 0.0 - 6.0 mph 25.7 - 26.8 24.6 - 25.7 23.5 - 24.6 22.4 - 23.5 21.3 - 22.4 20.1 - 21.3 19.0 - 20.1 17.9 - 19.0 16.8 - 17.9 15.7 - 16.8 14.5 - 15.7 13.4 -14.5 0.0 - 13.4 90" 89" 88" 87" U.S. Department of Energy National Renewable Energy Laboratory

F1147-E(10/2008)

REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 The public reporting burden for this collection of information is estimated to average 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden, to Department of Defense, Executive Services and Communications Directorate (0704-0188). Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to any penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number.

PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ORGANIZATION.

1. REPORT DATE (DD-MM-YYYY)

June 2010

2. REPORT TYPE Technical Report
3. DATES COVERED (From - To)
4. TITLE AND SUBTITLE Assessment of Offshore Wind Energy Resources for the United States 5a. CONTRACT NUMBER DE-AC36-08-GO28308 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER
6. AUTHOR(S)

M. Schwartz, D. Heimiller, S. Haymes, and W. Musial 5d. PROJECT NUMBER NREL/TP-500-45889 5e. TASK NUMBER WE10.1211 5f. WORK UNIT NUMBER

7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES)

National Renewable Energy Laboratory 1617 Cole Blvd.

Golden, CO 80401-3393

8. PERFORMING ORGANIZATION REPORT NUMBER NREL/TP-500-45889
9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES)
10. SPONSOR/MONITOR'S ACRONYM(S)

NREL

11. SPONSORING/MONITORING AGENCY REPORT NUMBER
12. DISTRIBUTION AVAILABILITY STATEMENT National Technical Information Service U.S. Department of Commerce 5285 Port Royal Road Springfield, VA 22161
13. SUPPLEMENTARY NOTES
14. ABSTRACT (Maximum 200 Words)

This report summarizes the offshore wind resource potential for the contiguous United States and Hawaii as of May 2009. The development of this assessment has evolved over multiple stages as new regional meso-scale assessments became available, new validation data was obtained, and better modeling capabilities were implemented. It is expected that further updates to the current assessment will be made in future reports.

15. SUBJECT TERMS offshore wind resource potential; United States offshore wind; assessment of offshore wind; meso-scale assessment; modeling of offshore wind
16. SECURITY CLASSIFICATION OF:
17. LIMITATION OF ABSTRACT UL
18. NUMBER OF PAGES 19a. NAME OF RESPONSIBLE PERSON
a. REPORT Unclassified
b. ABSTRACT Unclassified
c. THIS PAGE Unclassified 19b. TELEPHONE NUMBER (Include area code)

Standard Form 298 (Rev. 8/98)

Prescribed by ANSI Std. Z39.18