From:
Cotton, Karen Sent:
Wednesday, November 24, 2010 11:03 AM To:
Blechman, Paula
Subject:
FW: Response to Request for Additional Informaton Attachments:
SPT-004 and 003 NRC RAI Response.pdf From: Barry Garber [1]
Sent: Friday, November 19, 2010 6:26 PM To: Cotton, Karen; Nove, Carol Cc: Gary D Miller; Ed Turko
Subject:
Response to Request for Additional Informaton During a conference call between the NRC and Dominion on November 18, 2010, Dominion discussed the recently approved Surry Units 1 and 2 Relief Requests SPT-004, Rev. 2 and SPT-003, Rev. 2, respectively, associated with inservice inspection of the reactor pressure vessel (RPV) bottom mounted instrumentation (BMI) penetrations. As a result of the discussion, the NRC requested additional information. The NRCs questions, provided in an email from the Surry NRC Project Manager Karen Cotton on November 19, 2010 to Gary Miller of Dominion, and Dominions responses are provided in the attached document.
Please contact me or Gary Miller if you have further questions.
Barry A. Garber Supervisor Licensing Station Safety & Licensing, Surry Power Station Dominion Generation Phone: 757-365-2725; Internal: 8-798-2725 Fax: 757-365-2724; Mobile: 757-876-2751 Pager: 1-800-272-5643, pager# 7092; E-mail: barry.garber@dom.com CONFIDENTIALITY NOTICE: This electronic message contains information which may be legally confidential and/or privileged and does not in any case represent a firm ENERGY COMMODITY bid or offer relating thereto which binds the sender without an additional express written confirmation to that effect. The information is intended solely for the individual or entity named above and access by anyone else is unauthorized. If you are not the intended recipient, any disclosure, copying, distribution, or use of the contents of this information is prohibited and may be unlawful. If you have received this electronic transmission in error, please reply immediately to the sender that you have received the message in error, and delete it. Thank you.
E-mail Properties
Mail Envelope Properties (377CB97DD54F0F4FAAC7E9FD88BCA6D02B14825098)
Subject:
FW: Response to Request for Additional Informaton Sent Date: 11/24/2010 11:03:07 AM Received Date: 11/24/2010 11:03:07 AM From: Cotton, Karen Created By: Karen.Cotton@nrc.gov Recipients:
Paula.Blechman@nrc.gov (Blechman, Paula)
Tracking Status: None Post Office:
HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 215832 11/24/2010 SPT-004 and 003 NRC RAI Response.pdf 199792 Options Expiration Date:
Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: