ML103270435

From kanterella
Jump to navigation Jump to search

Tech Spec Pages for Braidwood and Byron Amendment Large Break Loss-of-Coolant Accident Analysis Using ASTRUM
ML103270435
Person / Time
Site: Byron, Braidwood  
Issue date: 12/21/2010
From: David M
Plant Licensing Branch III
To: Pacilio M
Exelon Nuclear
David Marshall NRR/DORL/LPL3-2 415-154
Shared Package
ML103270423 List:
References
TAC ME2941, TAC ME2942, TAC ME2943, TAC ME2944
Download: ML103270435 (1)


Text

Reporting Requirements 5.6 BRAIDWOOD UNITS 1 & 2 5.6 4 Amendment 5.6 Reporting Requirements 5.6.5 CORE OPERATING LIMITS REPORT (COLR) (continued)

5.

ComEd letter from D. Saccomando to the Office of Nuclear Reactor Regulation dated December 21, 1994, transmitting an attachment that documents applicable sections of WCAP-11992/11993 and ComEd application of the UET methodology addressed in "Additional Information Regarding Application for Amendment to Facility Operating Licenses-Reactivity Control Systems."

6.

WCAP-16009-P-A, Revision 0, "Realistic Large-Break LOCA Evaluation Methodology Using the Automated Statistical Treatment of Uncertainty Method (ASTRUM)," January 2005.

7.

WCAP-10079-P-A, "NOTRUMP, A Nodal Transient Small Break and General Network Code," August 1985.

8.

WCAP-10054-P-A, "Westinghouse Small Break ECCS Evaluation Model using NOTRUMP Code," August 1985.

9.

WCAP-10216-P-A, Revision 1, "Relaxation of Constant Axial Offset Control - FQ Surveillance Technical Specification," February 1994.

10.

WCAP-8745-P-A, "Design Bases for the Thermal Overpower T and Thermal Overtemperature T Trip Functions,"

September 1986;

c.

The core operating limits shall be determined such that all applicable limits (e.g., fuel thermal mechanical limits, core thermal hydraulic limits, Emergency Core Cooling Systems (ECCS) limits, nuclear limits such as SDM, transient analysis limits, and accident analysis limits) of the safety analysis are met; and

d.

The COLR, including any midcycle revisions or supplements, shall be provided upon issuance for each reload cycle to the NRC.