ML103230004

From kanterella
Jump to navigation Jump to search

Withdrawal of Alternative Request IR-3-12 for the Use of ASME Code Case N-513-2
ML103230004
Person / Time
Site: Millstone 
Issue date: 11/18/2010
From: Price J
Dominion Nuclear Connecticut
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
10-658, IR-3-12, N-513-2, FOIA/PA-2011-0115
Download: ML103230004 (2)


Text

Dominion Nuclear Connecticut, Inc.

5000 Dominion Boulevard, Glen Allen, Virginia 23060 Web Address: www.dom. com November 18, 2010 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Serial No.

NSSLlMLC Docket No.

License No.10-658 RO 50-423 NPF-49 DOMINION NUCLEAR CONNECTICUT, INC.

MILLSTONE POWER STATION UNIT 3 WITHDRAWAL OF ALTERNATIVE REQUEST IR-3-12 FOR THE USE OF ASME CODE CASE N-513-2 In a letter dated May 28, 2009 (ADAMS Ascension No. ML101380042), Dominion Nuclear Connecticut, Inc. (DNC) submitted Alternative Request IR-3-12, for use of American Society of Mechanical Engineers (ASME) Code Case N-513-2 (Reference).

The duration of the proposed request was for the current Millstone Power Station Unit 3 (MPS3) third 10-year inservice inspection interval or until such time as Code Case N-513-3 was accepted for use in a later revision of Nuclear Regulatory Commission (NRC)

Regulatory Guide (RG) 1.147, "Inservice Inspection Code Case Acceptability, ASME Section XI, Division 1."

In October 2010, the NRC issued RG 1.147, Revision 16, which approved the use of ASME Code Case N-513-3.

Because this code case is now endorsed by the NRC, Alternative Request IR-3-12 is no longer needed.

Hence, DNC hereby withdraws its request for NRC approval of Alternative Request IR-3-12.

If you have any questions regarding this submittal, please contact Mr. William D.

Bartron at (860) 444-4301.

Sincerely,

~

J.

ice Vic resident - Nuclear Engineering Attachments: None Commitments made in this letter:

None

Reference:

DNC Letter 09-283, "Millstone Power Station Unit 3, Alternative Request IR-3-12 for the Use of ASME Code Case N-513-2," dated May 28, 2009.

cc:

u.s. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406-1415 C. J. Sanders, Project Manager U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Mail Stop 0-883 Rockville, MD 20852-2738 NRC Senior Resident Inspector Millstone Power Station Serial No.10-658 Docket No. 50-423 Withdrawal of Alternative Request IR-3-12 Page 2 of 2