From:
Feintuch, Karl Sent:
Tuesday, November 09, 2010 10:11 PM To:
'Byrne, Thomas' Cc:
Catron, Steve; Mitchell, Matthew
Subject:
ME4984 (DAEC) Request for Additional Information (RAI)
Attachments:
ME4984 DAEC RR NDE-014 RAI 2010-11-09 (from CVIB).docx By request dated November 6, 2010, (Agencywide Documents Access and Management System (ADAMS) Accession Number ML103120111), NextEra Energy Duane Arnold, LLC.
(Duane Arnold, the licensee), requested NRC authorization of an alternative to the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code,Section XI, Rules for Inservice Inspection of Nuclear Power Plant Components. The proposed alternative would permit the use of a full structural weld overlay repair for an indication identified in the N2A Recirculation Inlet Safe End to Safe End Extension Dissimilar Metal Weld (RRA-F002A).
During the course of its review of the request for authorization of the alternative, the NRC staff identified a need for additional information. NRC Project Manager Karl Feintuch contacted Thomas Byrne of the Duane Arnold staff to convey a draft set of Request for Additional Information (RAI) items, which was discussed with licensee staff during a conference call on November 9, 2010, to clarify a mutual understanding of the responses that were needed.
During the phone call it was concluded that Duane Arnold could respond with the needed information by November 11, 2010. Duane Arnold indicated that it planned to submit a replacement in its entirety for the original request that was submitted by Duane Arnold and was dated November 6, 2010.
Attached is the final set of RAI items.
If there are any questions or a need to clarify this RAI please contact Karl Feintuch at 301-415-3079 or karl.feintuch@nrc.gov.
E-mail Properties Mail Envelope Properties (26E42474DB238C408C94990815A02F091367627935)
Subject:
ME4984 (DAEC) Request for Additional Information (RAI)
Sent Date: 11/9/2010 10:10:46 PM Received Date: 11/9/2010 10:10:00 PM From: Feintuch, Karl Created By: Karl.Feintuch@nrc.gov Recipients:
Thomas.Byrne@fpl.com ('Byrne, Thomas')
Tracking Status: None Steve.Catron@fpl.com (Catron, Steve)
Tracking Status: None Matthew.Mitchell@nrc.gov (Mitchell, Matthew)
Tracking Status: None Post Office:
HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 29711 11/9/2010 ME4984 DAEC RR NDE-014 RAI 2010-11-09 (from CVIB).docx 19027 Options Expiration Date:
Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: