River Bend Station Drill Date - September 02, 2010 Radiological Emergency Preparedness (REP) Program After Action Report/

Improvement Plan Published September 30, 2010

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station This page is intentionally blank.

River Bend Station After Action Report/Improvement Plan Published September 30, 2010 Contents Executive Summary 3

Section 1: Exercise Overview 4

1.1 Exercise Details 4

1.2 Exercise Planning Team Leadership 4

1.3 Participating Organizations 5

Section 2: Exercise Design Summary 6

2.1 Exercise Purpose and Design 6

2.2 Exercise Objectives, Capabilities and Activities 6

2.3 Scenario Summary 6

Section 3: Analysis of Capabilities 7

3.1 Drill Evaluation and Results 7

3.2 Summary Results of Drill Evaluation 7

3.3 Criteria Evaluation Summaries 9

3.3.1 Support Jurisdictions 9

3.3.1.1 Our Lady of the Lake Regional Hospital 9

3.3.2 Private Organizations 9

3.3.2.1 Acadian Ambulance Service 9

Section 4: Conclusion 10 Appendix A: Drill Evaluators and Team Leaders 11 Appendix B: Acronyms and Abbreviations 12 Appendix C: Exercise Plan 13 1

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

This page is intentionally blank.

2 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

EXECUTIVE

SUMMARY

On September 2, 2010, an out-of-sequence Medical Services drill was conducted for the River Bend Station (RBS), located near St. Francisville, Louisiana. Personnel from the U.S.Department of Homeland Security/Federal Emergency Management Agency (DHS/FEMA)

Region VI, evaluated all activities. The purpose of the drill was to assess the level of preparedness of local responders to react to a simulated radiological emergency at River Bend Station. The previous medical drill at this site was conducted on December 10, 2008. The previous plume and ingestion exercise was conducted on June 8-9, 2010.

Personnel from the State of Louisiana, River Bend Station, Our Lady of the Lake Regional Medical Center and Acadian Ambulance Service participated in the drill. Cooperation and teamwork of all the participants was evident during the drill and DHS/FEMA wishes to acknowledge these efforts.

This report contains the final evaluation of the out-of-sequence drill. The participants demonstrated knowledge of their emergency response plans and procedures and adequately demonstrated them. There were no Deficiences and no Areas Requiring Corrective Action (ARCAs) identified during the drill.

3 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

SECTION 1: EXERCISE OVERVIEW 1.1 Exercise Details Exercise Name River Bend Station Type of Exercise Drill Exercise Date September 02, 2010 Program Department of Homeland Security/FEMA Radiological Emergency Preparedness Program Scenario Type Radiological Emergency 1.2 Exercise Planning Team Leadership Lisa Hammond RAC Chair FEMA Region VI Technological Hazards Branch Chief 800 N. Loop 288 Denton, Texas, 76209 940-898-5199 lisa.hammond@dhs.gov Elsa Lopez Lead Planner FEMA Region VI Technical Hazards Program Specialist 800 N. Loop 288 4

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

Denton, Texas, 76209 940-898-5308 elsa.lopez@dhs.gov Cheryl Chubb State Planner Lousiana Department of Environmental Quality Environmental Scientist 602 N. Fifth Street Baton Rouge, Louisiana, 70802 225-219-3626 cheryl.chubb@la.gov 1.3 Participating Organizations Agencies and organizations of the following jurisdictions participated in the River Bend Station drill:

Support Jurisdictions Acadian Ambulance Service Our Lady of the Lake Regional Medical Center Private Organizations River Bend Station 5

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

SECTION 2: EXERCISE DESIGN

SUMMARY

2.1 Exercise Purpose and Design The DHS/FEMA Region VI Office evaluated the drill on September 2, 2010 to assess the capabilities of local emergency preparedness organizations in implementing their Radiological Emergency Response Plans and Procedures to protect the public health and safety during a radiological emergency involving River Bend Station (RBS). The purpose of this report is to represent the results and findings on the performance of the offsite response organizations during a simulated radiological emergency.

2.2 Exercise Objectives, Capabilities and Activities Exercise objectives and identified Capabilities/REP Criteria selected to be exercised are discussed in the Exercise Plan (EXPLAN), Appendix C.

2.3 Scenario Summary The drill scenario was developed to evaluate the response of drill participants to an incident requiring evacuation of the public from the Louisiana portion of the 10-mile Emergency Planning Zone surrounding the River Bend Station. The drill scenario provided for the evaluation of the Our Lady of the Lake Regional Medical Center and Acadian Ambulance Service's ability of transportation and treatment of a contaminated injuried individual.

6 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

SECTION 3: ANALYSIS OF CAPABILITIES 3.1 Drill Evaluation and Results Contained in this section are the results and findings of the evaluation of all jurisdictions and functional entities that participated in the September 2, 2010 drill to test the offsite emergency response capabilities of state and local governments in the 10-mile EPZ surrounding the River Bend Station.

Each jurisdiction and functional entity was evaluated on the basis of its demonstration of criteria delineated in the exercise evaluation areas as outlined in the April 25, 2002, Federal Register, Radiological Emergency Preparedness: Evaluation Methodology. Detailed information on the exercise evaluation area criteria and the extent of play agreement used in this drill are found in Appendix C of this report.

3.2 Summary Results of Drill Evaluation The matrix presented in Table 3.1, on the following page, represents the status of all exercise evaluation area criteria that were scheduled for demonstration during this exercise by all participating jurisdictions and functional entities. Exercise criteria are listed by number and the demonstration status is indicated by the use of the following letters:

M - Met (No Deficiency or ARCAs assessed and no unresolved ARCAs from prior exercises)

D - Deficiency assessed A - ARCA(s) assessed or unresolved ARCA(s) from prior exercise(s)

N - Not Demonstrated (Reason explained in Subsection 4.2) 7 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

Table 3.1 - Summary of Drill Evaluation DATE: 2010-09-02 SITE: River Bend Station, LA M: Met, A: ARCA, D: Deficiency, P: Plan Issue, N: Not Demonstrated AAS OLOL Emergency Operations Management Mobilization 1a1 Facilities 1b1 Direction and Control 1c1 Communications Equipment 1d1 Equip & Supplies to support operations 1e1 M

M Protective Action Decision Making Emergency Worker Exposure Control 2a1 Radiological Assessment and PARs 2b1 Decisions for the Plume Phase -PADs 2b2 PADs for protection of special populations 2c1 Rad Assessment and Decision making for the Ingestion Exposure Pathway 2d1 Rad Assessment and Decision making concerning Relocation, Reentry, and Return 2e1 Protective Action Implementation Implementation of emergency worker exposure control 3a1 M

M Implementation of KI decision 3b1 Implementation of protective actions for special populations - EOCs 3c1 Implementation of protective actions for Schools 3c2 Implementation of traffic and access control 3d1 Impediments to evacuation are identified and resolved 3d2 Implementation of ingestion pathway decisions - availability/use of info 3e1 Materials for Ingestion Pathway PADs are available 3e2 Implementation of relocation, re-entry, and return decisions.

3f1 Field Measurement and Analysis Adequate Equipment for Plume Phase Field Measurements 4a1 Field Teams obtain sufficient information 4a2 Field Teams Manage Sample Collection Appropriately 4a3 Post plume phase field measurements and sampling 4b1 Laboratory operations 4c1 Emergency Notification and Public Info Activation of the prompt alert and notification system 5a1 Activation of the prompt alert and notification system - Fast Breaker 5a2 Activation of the prompt alert and notification system - Exception areas 5a3 Emergency information and instructions for the public and the media 5b1 Support Operations/Facilities Mon / decon of evacuees and emergency workers, and registration of evacuees 6a1 Mon / decon of emergency worker equipment 6b1 Temporary care of evacuees 6c1 Transportation and treatment of contaminated injured individuals 6d1 M

M 8

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

a.

b.

c.

d.

e.

f.

g.

a.

b.

c.

d.

e.

f.

g.

3.3 Criteria Evaluation Summaries 3.3.1 Support Jurisdictions 3.3.1.1 Our Lady of the Lake Regional Hospital MET: 1.e.1, 3.a.1, 6.d.1.

AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None PLAN ISSUES: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 3.3.2 Private Organizations 3.3.2.1 Acadian Ambulance Service MET: 1.e.1, 3.a.1, 6.d.1.

AREAS REQUIRING CORRECTIVE ACTION: None DEFICIENCY: None PLAN ISSUES: None NOT DEMONSTRATED: None PRIOR ISSUES - RESOLVED: None PRIOR ISSUES - UNRESOLVED: None 9

Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

SECTION 4: CONCLUSION Based on the results of the drill, the offsite radiological emergency response plans and preparedness for the State of Louisiana and the affected local jurisdictions are deemed adequate to provide reasonable assurance that appropriate measures can be taken to protect the health and safety of the public in the event of a radiological emergency. Therefore, 44 CFR Part 350 approval of the offsite radiological emergency response plans and preparedness for the State of Louisiana site-specific to River Bend Station will remain in effect.

10 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

APPENDIX A: DRILL EVALUATORS AND TEAM LEADERS DATE: 2010-09-02, SITE: River Bend Station, LA LOCATION EVALUATOR AGENCY Our Lady of the Lake Regional Hospital Bill Bischof Elsa Lopez

  • Tim Pflieger DHS/FEMA DHS/FEMA DHS/FEMA Acadian Ambulance Service
  • Linda Gee DHS/FEMA

After Action Report/Improvement Plan River Bend Station

APPENDIX B: ACRONYMS AND ABBREVIATIONS Acronym Meaning ARCA Areas Requiring Corrective Action DHS/FEMA Department of Homeland Security/Federal Emergency Management Agency DLR Dosimeter of Legal Record EPZ Emergency Planning Zone EXPLAN Exercise Plan KI Potassium Iodide OLOL Our Lady of the Lake Regional Medical Center ORO Offsite Response Organization PIC Pocket Ion Chamber PPE Personal Protective Equipment RBS River Bend Station REA Radiation Emergency Area REP Radiological Emergency Preparedness RP Radiation Protection Technician RSO Radiation Safety Officer 12 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

APPENDIX C: EXERCISE PLAN 13 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RADIOLOGICAL EMERGENCY MEDICAL DRILL SCENARIO FOR RIVER BEND STATION OUR LADY OF THE LAKE REGIONAL MEDICAL CENTER AND ACADIAN AMBULANCE SERVICE RDRL-EP-10MS1DRIL 14 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES I

PURPOSE This simulated radiation medical emergency is being conducted in order to exercise the emergency medical response at River Bend Station and the secondary medical support facility, Our Lady of the Lake Regional Medical Center and Acadian Ambulance Service. The basic objective is to assess the ability of the plant staff to respond effectively to a radiation medical emergency within the plant and to test the ability of hospital and ambulance emergency service to handle contaminated and injured patients.

II PROPOSED SCHEDULE DATE:

September 2, 2010 TIME:

6:30 AM (Start time at River Bend Station)

LOCATIONS:

River Bend Station & Our Lady of the Lake Regional Medical Center INJURY/ILLNESS:

Fall victim conscious and bleeding 15 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES III EVALUATION AREAS AND EXTENT-OF-PLAY-OFFSITE EVALUATION AREA 1: EMERGENCY OPERATIONS MANAGEMENT Sub-element 1.e - Equipment and Supplies to Support Operations Criterion 1.e.1: Equipment, maps, displays, dosimetry, potassium iodide (KI), and other supplies are sufficient to support emergency operation. (NUREG-0654, H.7, 10; J.10.a, b, e J.11; K.3.a)

Locations Our Lady of the Lake Regional Medical Center and Acadian Ambulance Service Extent of Play The ambulance crew should be knowledgeable on how to acquire dosimetry kits and potassium iodide (KI) during a declared emergency. The ambulance crew will discuss the method of obtaining dosimetry kits and KI from the parish when an emergency has been declared at the nuclear power plant. The discussion can be accomplished by interview with the evaluator. In accordance with the scenario for this evaluation, the utility will provide necessary dosimetry to the ambulance crew.

Correction-on-the-spot will be applicable for this demonstration.

EVALUATION AREA 3: PROTECTIVE ACTION IMPLEMENTATION Sub-element 3.a - Implementation of Emergency Worker Exposure Control Criterion 3.a.1: The OROs issue appropriate dosimetry and procedures, and manage radiological exposure to emergency workers in accordance with the plans and procedures.

Emergency workers periodically and at the end of each mission read their dosimeters and record the readings on the appropriate exposure record or chart. (NUREG-0654, K.3.a, b)

Locations Our Lady of the Lake Regional Medical Center and Acadian Ambulance Service Extent of Play Dosimeters and a simulated DLR (dosimeter of legal record) will be issued to participating ambulance crew members by River Bend Station plant personnel. Hospital personnel will be issued dosimeters and DLRs at the hospital. Ambulance crew members will be prepared to discuss the method by which they would acquire dosimetry kits from the ambulance in the event of a declared emergency.

Correction-on-the-spot will be applicable for this demonstration.

16 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES EVALUATION AREA 6: SUPPORT OPERATION/FACILITIES Sub-element 6.d--Transportation and Treatment of Contaminated Injured individuals Criterion 6.d.1: The facility/ORO has the appropriate space, adequate resources, and trained personnel to provide transport, monitoring, decontamination, and medical services to contaminated injured individuals. (NUREG-0654, F.2; H.10; K.5.a, b; L.1, 4)

Locations Our Lady of the Lake Regional Medical Center and Acadian Ambulance Service Extent of Play The ambulance service will pre-stage at the River Bend Training Center to facilitate a security check prior to the drill for entrance into the protected area. The ambulance will pick up the victim inside the protected area. Removal of victims clothing will be simulated.

At the hospital, decontamination will be demonstrated to the evaluators using methods contained in the hospital procedure. These methods could include soap and water, wipes, or tape. Intrusive bioassay samples will be simulated. No actual surgical procedures, X-ray, drawing of blood samples, etc. will be conducted.

Correction-on-the-spot will be applicable for this demonstration.

Onsite Objectives

1. Demonstrate the use of emergency teams - onsite first aid (medical).
2. Demonstrate the capability to communicate with all appropriate emergency personnel at facilities and in the field.

GENERAL EXTENT-OF-PLAY (EOP):

1.

With regard to last minute additions or changes to any previously approved Extent-of-Play, all suggested changes must be forwarded to the RAC Chair for approval.

2.

The goal of all offsite response organizations (ORO) is to protect the health and safety of the public.

This goal is achieved through the execution of appropriate plans and procedures. It is recognized that situations may arise that could limit the organizations in the exact execution of these plans and procedures.

3.

In the event of an unanticipated situation, OROs are permitted to exercise flexibility in the implementation of their plans and procedures in order to successfully achieve the objective of protection of public health and safety and protection of the environment.

4.

As a statement of fact, no ORO will deliberately deviate from its plans and procedures with the intent of avoiding responsibility.

References:

As indicated in the Extent-of-Play Agreement, the State of Louisiana requests the option to correct issues immediately as defined in FEMA Policy Paper, Strategic Review Steering Committee, Initiative 1.5, Correct Issues Immediately, effective March 31, 2000, signed by Kay C. Goss, CEM, Associate Director for 17 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES Preparedness, Training and Exercises. Acceptable locations/activities for on-the-spot-correction are clearly indicated in the extent of play portion under each criterion.

18 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES EXERCISE CONTROLLERS/EVALUATORS Norman Tison Control Room 2789 John Standridge Plant site (Radiological response) 721-0887 Fred Hurst Plant site (First Aid Team)/Ambulance 324-6020 Gil Cosnett Our Lady of the Lake Regional Medical 1-856-261-5760 Center EXERCISE OBSERVERS Cheryl Chubb Hospital Greg Gothard Hospital Ji Wiley Ambulance ONSITE PHONE NUMBERS Shift Manager 2776 --OSM/Communicator Console 2789 RP 2771 19 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES NARRATIVE SCENARIO Approximate Time:

0630 Location:

65 Level, Radwaste Building

==

Description:==

An individual investigating radiation alarms in the Radwaste Building near Phase Separator Tank TK-6B slips, and falls while climbing on maintenance scaffolding. During the fall, he hits a sharp object and is injured and contaminated with spilled resins and water. The individual will be found on the floor by a co-worker, conscious, and bleeding slightly from a leg wound. The individual will be carried from the contaminated area by the co-worker in an attempt to seek help at the RCA control point. The individual, however, collapses prior to reaching the RCA control point. The control room is then called for assistance.

Expected actions:

When contacted, the operations shift manager should implement the steps of ADM-0060, First Responder Emergencies. The First Responders should be contacted and RP support requested.

The first aid team responding to the call should perform an assessment of the patients condition and treat any life-threatening injuries. Based on the individuals condition and vital signs, the responding First Responders should make the decision to transport without decontamination. The control room should be contacted to arrange for ambulance and hospital support based on ADM-0060.

Radiation protection should monitor radiological exposures for both the responders and the patient.

Contamination controls which do not impact care of the patient should be employed. Consideration should also be given to the path the patient took from the original accident scene.

While awaiting ambulance arrival, the first aid team should perform the necessary actions to prepare the patient for transport. Assistance should be requested for patient transfer and the Primary Access Point (PAP) should be informed to prepare for ambulance arrival. RP should assist in planning the patient move to the ambulance pick up point.

Upon arrival of the ambulance, a turnover of patient medical and radiological conditions should be provided to the ambulance personnel. RP should arrange for two technicians to provide radiological coverage for the patient and medical personnel while in route and at the hospital.

20 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES The onsite portion of the drill will be evaluated by Emergency Planning and Training department personnel. The individual will be transported to the hospital where FEMA will observe hospital activities in accordance with the stated objectives.

21 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES Pre-Staging:

The ambulance will be pre-staged near River Bend Station to help ensure expedited entry into the security area. This will allow for an arrival time at Our Lady of the Lake Regional Medical Center at approximately 8:15 AM.

Scenario Timeline 0700 Ambulance enters River Bend Station 0735 Ambulance departs site 0815 Ambulance arrives at Our Lady of the Lake Regional Medical Center 0930 Drill Terminated 22 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES CONTROLLER MESSAGE Message:

CONTROL ROOM CONTROLLER ---MAKE PRE-DRILL ANNOUNCEMENT Number # 1 Time: 0625

////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

This is to announce the start of the 2010 Medical Drill.

NOTE: Merge the Page Party /Gaitronics and make plant announcement Pulse Tone.

Attention in the plant. The Emergency Planning 2010 Medical Drill is beginning. Drill announcements will be preceded by This is a Drill and are intended for drill participants only. All other personnel should ignore the drill messages.

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

23 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES CONTROLLER MESSAGE Message:

ACCIDENT SCENE-CONTROLLER Number:-# 2 Time: 0630

////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL CONTROLLER: Call Control Room ask for OSM EXT. 2299

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Report of finding the victim; First Call This is (state your name)

(Victims name)- has fallen and requires medical help. He is currently located in the 123 T-tunnel near the RCA control point. He was injured in the Radwaste Building near Phase Separator Tank TK-6B. He is conscious and bleeding from a leg wound. He may be contaminated.

NOTE: Second Call should be made by First Responders on status of victim and request for ambulance.

Victim is conscious; bleeding slightly from a leg wound.

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

24 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES CONTROLLER MESSAGE Message:

ACCIDENT SCENE-CONTROLLER Number # 3

////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

RADIATION SURVEY RESULTS General Area Survey = as found General contamination readings on injured man = <1mR/hr/4000cpm General Area Smears = as found.

Injureds pocket EAD = as found Air Sample = as found Controller Note: Issue data message information only after Radiation Protection Technicians have started survey.

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

25 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES ANATOMICAL DIAGRAM 3 Lg. X 1/2 Deep Cut---

contaminated area 1 around wound 26 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES CONTROLLER MESSAGE Message:

MEDICAL INFORMATION Number # 4

////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Phase 1 Phase 2 Phase 3 Discovery First Aid Team Arrival EMS Arrival Patient found conscious Pulse:

90, strong Vitals Unchanged and bleeding slightly from a Resp.:

24, regular leg wound B. P.:

106/70 Leg wound 1/2 in. deep x 3 in. lg. Skin:

Pale, warm, dry NOTE: Patient will remain conscious during the drill.

Phase 4 Phase 5 Phase 6 EMS Transport Hospital Arrival Hospital Treatment Pulse:

88, strong Vitals Unchanged Pulse:

92, strong Resp.:

20, regular Resp.:

12, regular B.P.

112/74 B. P.:

118/78 Skin:

color good, Skin:

color good, warm, dry warm, dry

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

27 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES CONTROLLER MESSAGE Message: HOSPITAL RADIOLOGICAL DATA Number # 5

////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

Patient Arrival Clothing: (near wound) 4000cpm. (See note)

Leg Wound:

4000cpm Note: Contaminated clothing may have been removed at the plant per RP procedures.

After 1st Decontamination Clothing:

Removed Leg Wound:

1,500 cpm After 2nd Decontamination Leg Wound:

1,000 cpm After 3rd Decontamination All areas background: 60 cpm

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

28 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES CONTROLLER MESSAGE Message:

PLANT INFORMATION-CONTROLLER Number # 6

////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

/////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

NOTE: Controller is to ensure the Control Room is notified that the ambulance has exited the site.

This is to announce the termination of the 2010 Medical Drill.

NOTE: Merge the Page Party /Gaitronics and make plant announcement Pulse Tone.

Attention in the plant. The Emergency Planning 2010 Medical Drill is terminated. (Repeat announcement.)

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

THIS IS A DRILL

//////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////

29 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

RIVER BEND STATION 2010 MEDICAL EMERGENCY RESPONSE EVALUATED DRILL EVALUATION AREAS AND EXTENT-OF-PLAY (EOP) AGREEMENT & ONSITE OBJECTIVES ATTENTION THERE WILL BE AN ONSITE MEDICAL DRILL TODAY 9/2/10 ACADIAN AMBULANCE SERVICE WILL BE ONSITE 30 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

This page is intentionally blank.

31 Unclassified Radiological Emergency Preparedness Program (REP)

After Action Report/Improvement Plan River Bend Station

_____________________________________________________________________