REED COLLEGE October 5, 2010 5cIIntCbniif tr61' D&§k
§.S; Nuclea aRegulatory Commission REACTOR Washington, DC 20555 RATRFACILITY 3203 Southeast Docket:
50-288 Woodstock Boulevard License No: R-1 12 Portland, Oregon 97202-8199 telep*hone 503/777-7222 We have reanalyzed the decommissioning costs for the Reed College Research Reactor.
The new estimate is approximately $2,250,000. Please see attached for details.
fax I declare under penalty of perjury that the foregoing is true and correct.
503/777-7274 eeartor@reed.edu Executed on S-web hrp:Hreactor.reed.edu S.
D he reantzed R MfDi~c6f-,TReed'M* e-af'fi Reactor
ýJ
Decommission Costs for the Reed College Research Reactor in 2010 Dollars A. LLRW Burial Costs: $105,000 Disposal costs at Richland, WA in 2010: z $200/ft3.
Volume of material to be disposed: 522 ft3
- 1. Aluminum tank liner and 6 inches of concrete next to the liner: 467 ft3
- 2. Rotating Specimen Rack and Reflector: 12 ft3
- 3. Core Support Structure: 10 ft3
- 4. Miscellaneous: 25 ft3 Disposal costs = ($200/ft3) (522 ft3)
$105,000 B. Labor Costs: $1,600,000 Staff Work-years Rate ($/hr)
Cost ($)
Director 1.00
$50
$100,000 Assoc. Director 1.00
$20
$40,000 Clerical 0.25
$50
$25,000 Health Physicist 0.25
$50
$25,000 QA Engineer 0.25
$100
$50,000 Consultant 0.25
$100
$50,000 Labor Shift Engineer 1.00
$75
$150,000 Craftsmen 2.00
$75
$300,000 Crew Leader 0.50
$75
$75,000 Utility Operator 0.25
$75
$37,500 Labor 4.00
$75
$600,000 HP Tech 1.00
$75
$150,000 Total z $1,600,000 C. Support Costs for Spent Fuel Shipment: $100,000.
D. 25% Contingency: $450,000.
Total: $2,250,000
?