LR-N10-0346, Response to NRC Request for Additional Information Re CASS Materials & CASS Safety Injection Valves
| ML102560065 | |
| Person / Time | |
|---|---|
| Site: | Salem |
| Issue date: | 09/07/2010 |
| From: | Braun R Public Service Enterprise Group |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| LR-N10-0346 | |
| Download: ML102560065 (14) | |
Text
PSEG Nuclear LLC PO. Box 236, Hancocks Bridge, NJ 08038 0 PSEG Nuclear LLC SEP 7 2010 10 CFR 50 10 CFR 51 10 CFR 54 LR-N10-0346 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Salem Nuclear Generating Station, Unit No. 1 and Unit No. 2 Facility Operating License Nos. DPR-70 and DPR-75 NRC Docket Nos. 50-272 and 50-311
Subject:
Response to NRC Request for Additional Information dated August 9, 2010, Related to CASS Materials; and, Response to NRC Request for Additional Information dated August 19, 2010 Pertaining to CASS Safety Injection Valves, both associated with the Salem Nuclear Generating Station, Units 1 and 2 License Renewal Application
Reference:
- 1. Letter from Ms. Bennett Brady (USNRC) to Mr. Thomas Joyce (PSEG Nuclear, LLC) "REQUEST FOR ADDITIONAL INFORMATION FOR SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION (TAC NOS. ME1 834 AND ME1 836)," dated August 9, 2010
- 2. Letter from Ms. Bennett Brady (USNRC) to Mr. Thomas Joyce (PSEG Nuclear, LLC) "REQUEST FOR ADDITIONAL INFORMATION REGARDING THE SALEM NUCLEAR GENERATING STATION, UNITS 1 AND 2, LICENSE RENEWAL APPLICATION (TAC NO. ME1834 AND ME1836), dated August 19, 2010 In Reference 1, the NRC requested additional information related to management of stress corrosion cracking of cast austenitic stainless steel (CASS) materials, associated with the Salem Nuclear Generating Station, Units 1 and 2 (Salem) License Renewal Application.
Reference 2 requested information pertaining to the Salem Safety Injection system cold leg CASS injection check valves. Enclosed are the responses to these requests for additional information.
This letter and its enclosure contain no regulatory commitments.
If you have any questions, please contact Mr. Ali Fakhar, PSEG Manager - License Renewal, at 856-339-1646.
1f4
Document Control Desk LR-N10-0346 Page 2 of 2 SEP 72010 I declare under penalty of perjury that the foregoing is true and correct.
Executed on Sincerely, Robert C. Braun Senior Vice President, Operations PSEG Nuclear LLC
Enclosure:
Responses to Requests for Additional Information Related to CASS Materials and Components cc:
Regional Administrator - USNRC Region I B. Brady, Project Manager, License Renewal - USNRC R. Ennis, Project Manager - USNRC NRC Senior Resident Inspector - Salem P. Mulligan, Manager IV, NJBNE L. Marabella, Corporate Commitment Tracking Coordinator Howard Berrick, Salem Commitment Tracking Coordinator
Enclosure LR-N1 10-0346 Page 1 of 12 Enclosure Responses to Requests for Additional Information Related to CASS Materials and Components, associated with the Salem Nuclear Generating Station, Units 1 and 2 License Renewal Application (LRA)
RAI 3.1.2.2.7.2-01 RAI 3.2.1.47-01
Enclosure LR-N 10-0346 Page 2 of 12 RAI 3.1.2.2.7.2-01
Background:
License renewal application (LRA) Section 3.1.2.2.7.2 addresses the aging management of cracking due to stress corrosion cracking (SCC) of Class 1 cast austenitic stainless steel (CASS) piping and piping components exposed to reactor coolant. LRA Table 3.1.1 item 3.1.1-24, which also refers to LRA Section 3.1.2.2.7.2, addresses the applicant's aging management of SCC in the CASS components. The applicant stated that the aging effect will be managed by implementing the Water Chemistry Program (LRA Section B.2.1.2) and Thermal Aging Embrittlement of Cast Austenitic Stainless Steel Program (LRA Section B.2.1.6).
LRA Section B.2.1.6 states that the Thermal Aging Embrittlement of CASS Program is consistent with GALL AMP XI.M12, 'Thermal Aging Embrittlement of Cast Austenitic Stainless Steel (CASS)," with no exception or enhancement. LRA Section B.2.1.6 also indicates that the applicant's program includes the inspections, flaw evaluations, and repairs and replacements in accordance with the ASME Section Xl Inservice Inspection, Subsections IWB, IWC, and IWD Program.
Issue:
The staff noted that the material screening criteria used to manage the thermal aging embrittlement of CASS, as described in GALL AMP XI.M12, are different from the material screening criteria used to further evaluate and manage the SCC of CASS as described under GALL Report item IV.C2-3.
In order to adequately manage the SCC of CASS components under GALL Report item IV.C2-3, the GALL Report recommends further evaluation for CASS that has carbon content greater than 0.035 percent or ferrite content less than 7.5 percent. In contrast, the material screening criteria of the Thermal Aging Embrittlement of CASS Program are based on the combinations of molybdenum content, different threshold levels of ferrite content (14 percent and 20 percent) and casting methods (static casting and centrifugal casting). Therefore, the staff found the need to clarify whether the applicant's material screening criteria used to manage the SCC applicant's aging management method are consistent with GALL Report item IV.C2-3.
Request:
- 1. Clarify how the applicant's material screening criteria used to further evaluate and manage the SCC of CASS are consistent with GALL Report item IV.C2-3 which recommends that SCC of CASS with carbon content greater than 0.035 percent or ferrite content less than 7.5 percent be further evaluated and adequately managed.
- 2. Clarify whether the SCC in the CASS components is managed by the inspections, flaw evaluations, and repairs and replacements in accordance with the ASME Section XI Inservice Inspection, Subsections IWB, IWC and IWD Program. If the ASME Section XI Inservice Inspection, Subsections IWB, IWC and IWD Program is not used to manage the aging effect, justify why the applicant's program is adequate to manage the aging effect.
Enclosure LR-N10-0346 Page 3 of 12 PSEG Response:
- 1. The material screening criteria used to further evaluate and manage the aging effect and mechanism of cracking due to stress corrosion cracking (SCC) of Class 1 cast austenitic stainless steel (CASS) components are consistent with Generic Aging Lessons Learned (GALL) Report item IV.C2-3. The recommended aging management program for this aging effect and mechanism is the Water Chemistry Program (Salem LRA Appendix B, Section B.2.1.2). For CASS components that do not meet the NUREG-0313 guidelines of carbon content of less than or equal to 0.035 percent and ferrite content of greater than or equal to 7.5 percent, then GALL item IV.C2-3 recommends a plant-specific aging management program is to be evaluated. Salem reviewed the chemical compositions of the CASS components exposed to reactor coolant, and it was identified that these CASS components do not meet the NUREG-0313 guidelines. Salem LRA inappropriately credited the Thermal Aging Embrittlement of Cast Austenitic Stainless Steel (CASS) aging management program (Salem LRA Appendix B, Section B.2.1.6) as the plant-specific program in LRA Table 3.1.2-1.
Salem will instead credit the ASME Section Xl Inservice Inspection, Subsections IWB, IWC, and IWD aging management program (Salem LRA Appendix B, Section B.2.1.1) to manage the aging effect and mechanism of cracking due to SCC for the Class 1 CASS components exposed to reactor coolant. In addition, as shown in the Salem LRA Table 3.1.2-1, Salem appropriately credits the Thermal Aging Embrittlement of Cast Austenitic Stainless Steel (CASS) aging management program to manage the aging effect and mechanism of loss of fracture toughness due to thermal aging embrittlement.
- 2. The aging effect and mechanism of cracking due to SCC for the Class 1 CASS components exposed to reactor coolant will be managed by the ASME Section XI Inservice Inspection, Subsections IWB, IWC and IWD aging management program as revised per this RAI response. As discussed in Salem LRA Section B.2.1.1, the ASME Section XI Inservice Inspection, Subsections IWB, IWC and IWD aging management program uses inspections, flaw evaluations, and repairs and replacements, as required.
As a result of the above RAI response, LRA Table 3.1.1, Item Number 3.1.1-24, LRA Table 3.1.2-1, and LRA Section 3.1.2.2.7.2 are revised as shown below. Revisions are indicated with bolded italics for inserted text and strikethroughs for deleted text.
Enclosure LR-N10-0346 Page 4 of 12 Table 3.1.1 Summary of Aging Management Evaluations for the Reactor Vessel, Internals, and Reactor Coolant System Item Aging Aging Further Number Component Effect/Mechanism Management Evaluation Discussion Programs Recommended 3.1.1-24 Class 1 cast austenitic stainless steel piping, piping components, and piping elements exposed to reactor coolant Cracking due to stress corrosion cracking Water Chemistry and, for CASS components that do not meet the NUREG-0313 guidelines, a plant specific aging management program Yes, plant specific Consistent with NUREG-1801. Salem will implement the Water Chemistry program, B.2.1.2, to manage cracking due to stress corrosion cracking in the Class 1 cast austenitic stainless steel (CASS) reactor coolant system components and valve bodies exposed to reactor coolant.
Components in the Reactor Coolant System have been aligned to this item number based on material, environment and aging effect.
The ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD program, B.2.1.1, Thermal-Ag lmbrittlomRnt of Cast Au*+tnitir-,c Stainle, Stool (CASS) program, B.2.1.6, will be used added, along with the Water Chemistry program, B.2.1.2, to manage cracking due to stress corrosion cracking in the Class 1 cast austenitic stainless steel (CASS) reactor coolant system components exposed to reactor coolant.
See Subsection 3.1.2.2.7.2.
Enclosure LR-N 10-0346 Page 5 of 12 Table 3.1.2-1 Reactor Coolant System Component Intended Material Environment Aging Effect Aging Management NUREG-1801 Table 1 Notes Type Function Requiring Programs Vol. 2 Item Item Management Reactor Coolant Pressure Cast Austenitic Reactor Coolant Cracking/Stress Therma gin IV.C2-3 3.1.1-24 A
Pressure Boundary Stainless Steel (Internal)
Corrosion Cracking Embrittlement of Cast E, 9 Boundary (CASS)
Austenitic Stainless Components (hot Stee[(CASS) leg and cold leg ASME Section XI piping)
Inservice Inspection, Subsections IWB, IWC, and IWD Plant Specific Notes:
- 9. NUREG-1801 specifies a plant-specific program. The ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD program is used to manage the aging effect applicable to-this component type, material, and environment combination.
Enclosure LR-N 10-0346 Page 6 of 12 3.1.2.2.7 Cracking due to Stress Corrosion Cracking
- 2. Cracking due to SCC could occur in Class I PWR cast austenitic stainless steel (CASS) reactor coolant system piping, piping components, and piping elements exposed to reactor coolant. The existing program relies on control of water chemistry to mitigate SCC; however SCC could occur for CASS components that do not meet the NUREG-0313 guidelines with regard to ferrite and carbon content. The GALL Report recommends further evaluation of a plant specific program for these components to ensure that this aging effect is adequately managed. Acceptance criteria are described in Branch Technical Position RLSB-I.
Salem will implement the Water Chemistry program, B.2.1.2, and the ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD program, B.2.1.1, to manage cracking due to stress corrosion cracking in the Class 1 cast austenitic stainless steel (CASS) reactor coolant system components and valve bodies exposed to reactor coolant. Salem will implement Thermal Aging Ebri-rttipement of Cast Austenitic Stainless Steel (CASS) program, B.2.1.6, and the Water Chemistry progaram, B.2.1.2, to mnanage cracking due to stress corrosion r-ackiRg in the Class 1 cast austenitic stainless steel (CASS) rea*E*r cool-Rnt systemr components exposed to reactor* oolant. The ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD Therm*a A*g.ig Embhittlement f Cast
^,,tenitc
-Stainless Steel (CASS) program includes condition monitoring activities of reactor coolant system CASS components susceptible to cracking due to stress corrosion cracking thermal aging embrittlem.nt to ensure that there is no loss of intended function. The ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD Thermal Aging Embrittlement of Cast Austenitic Stainless Steel (CASS) program and the Water Chemistry program are described in Appendix B.
Enclosure LR-N 10-0346 Page 7 of 12 RAI 3.2.1.47-01
Background:
Standard Review Plan for Reviewed License Renewal Applications (SRP LR) Table 3.2-1, item 47 addresses loss of fracture toughness due to thermal aging embrittlement in cast austenitic stainless steel (CASS) piping, piping components, and piping elements exposed to treated water (borated or unborated) with temperature greater than 250'C (>482°F). License renewal application item 3.2.1-47 states that this line item is not applicable because there are no CASS piping, piping components or piping elements, subject to treated water greater than 4820F in the engineered safety features systems. Final Safety Analysis Report Table 6.3-14 states that valves in the emergency core cooling system are constructed of austenitic stainless steel.
Issue:
The staff does not have enough information to determine if the safety injection (SI) cold leg check valves (at the reactor coolant system (RCS) to Sl boundary) are constructed from CASS.
Also, given the valve's position, it's not evident if they're subject to an environment exceeding 4820F.
Request:
Are the safety injection cold leg check valves (at the RCS to Sl boundary) valves constructed of CASS and are they exposed to an environment exceeding 4820F?
PSEG Response:
The Safety Injection cold leg check valves at the Reactor Coolant System to Safety Injection system boundary are constructed of CASS material, and are assumed to be exposed to an environment of treated borated water > 4820F. As such, the Salem LRA should have included the Generic Aging Lessons Learned (GALL) Report item IV.C2-6 in LRA Table 3.2.2-3 for the component type Class 1 Valve Body for the Safety Injection cold leg check valves at the Reactor Coolant System to Safety Injection System boundary.
During normal operations, heat is transferred from the Reactor Coolant System cold leg (5500F) to the Safety Injection cold leg check valves through a stagnant vertical leg of piping. It can be assumed that the internal temperature of the Safety Injection System cold leg check valves at the Safety Injection System and Reactor Coolant System boundary is greater than 4820F.
Since these check valves are exposed to an internal environment of reactor coolant (treated borated water > 482°F), LRA Table 3.2.2-3 is revised to add the GALL Report item IV.C2-6 to the Safety Injection System component type Class 1 Valve Body. The corresponding aging effect and mechanism of loss of fracture toughness due to thermal aging embrittlement will be managed by the ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD aging management program (Salem LRA, Appendix B, Section B.2.1.1). The ASME Section XI Inservice Inspection, Subsections IWB, IWC, and IWD aging management program is adequate to manage the aging effect of loss of fracture toughness due to thermal aging embrittlement.
Enclosure LR-N 10-0346 Page 8 of 12 The GALL Report item IV.C2-6 further states that "screening for susceptibility to thermal aging is not necessary" for pump casings and valve bodies.
As a result of the above response, LRA Table 3.1.1, Item Number 3.1.1-55; LRA Table 3.2.1, Item Number 3.2.1-47; LRA Table 3.2.2-3, and LRA Section 3.2.2.1.3 are revised as shown below. Revisions are indicated with bolded italics for inserted text and strikethroughs for deleted text.
Enclosure LR-N 10-0346 Page 9 of 12 Table 3.2.2-3 Safety Injection System Component Intended Material Environment Aging Effect Aging NUREG-1801 Table 1 Notes Type Function Requiring Management Vol. 2 Item Item Management Programs Valve Body Pressure Cast Austenitic Treated Borated Water Loss of Fracture ASME Section Xl IV.C2-6 3.1.1-55 A
(Class 1)
Boundary Stainless Steel
>482OF Toughness/Thermal Inservice (CASS)
Aging Inspection, (Internal)
Embrittlement Subsections IWB, I_
IWC, and IWD
Enclosure LR-N 10-0346 Page 10 of 12 Table 3.1.1 Summary of Aging Management Evaluations for the Reactor Vessel, Internals, and Reactor Coolant System Item Aging Aging Further Number Component Effect/Mechanism Management Evaluation Discussion Programs Recommended 3.1.1-55 Cast austenitic Loss of fracture Inservice No Consistent with NUREG-1 801. The ASME stainless steel toughness due to inspection (IWB,Section XI Inservice Inspection program, Class 1 pump thermal aging IWC, and IWD).
Subsections IWB, IWC, and IWD, B.2.1.1, casings, and valve embrittlement Thermal aging will be used to manage the loss of fracture bodies and susceptibility toughness due to thermal aging bonnets exposed screening is not embrittlement in cast austenitic stainless to reactor coolant necessary, steel Class 1 pump casings and valve bodies
>250 0C (>4820F) inservice inspection exposed to reactor coolant and treated requirements are borated water > 4820 in the Chemical &
sufficient for Volume Control, a4d Reactor Coolant managing these Systems. and Safety Injection Systems.
aging effects.
ASME Code Case N-481 also provides an alternative for pump casings.
Enclosure LR-N 10-0346 Page 11 of 12 Table 3.2.1 Summary of Aging Management Evaluations for the Engineered Safety Features Item Aging Aging Further Number Component Effect/Mechanism Management Evaluation Discussion Programs Recommended 3.2,1-47 Cast austenitic Loss of fracture Thermal Aging No Not Applicable. There areis-Pq cast stainless steel toughness due to Embrittlement of austenitic stainless steel piping, piping piping, piping thermal aging CASS components, and piping elements exposed components, and embrittlement to treated borated water greater than 4820F piping elements in the Engineered Safety Features systems.
exposed to treated The cast austenitic stainless steel valves borated water exposed to treated borated water >4820F in
>2500C (>482 0F) the Chemical & Volume Control System and the Safety Injection Systems have been included in Table 3.1, Item Number 3.1.1-55.
Enclosure LR-N10-0346 Page 12 of 12 3.2.2.1.3 Safety Injection System Environments The Safety Injection System components are exposed to the following environments:
Treated Borated Water > 482 OF Aging Effects Requiring Management The following aging effects associated with the Safety Injection System components require management:
- Loss of Fracture Toughness/Thermal Aging Embrittlement