ML102450254
| ML102450254 | |
| Person / Time | |
|---|---|
| Site: | Columbia |
| Issue date: | 10/14/2009 |
| From: | Garchow S Operations Branch IV |
| To: | Energy Northwest |
| References | |
| Download: ML102450254 (4) | |
Text
ES-301 Administrative Topics Outline Form ES-301-1 Facility: Columbia Generating Station Date of Examination: October 2009 Examination Level: RO X SRO Operating Test Number: 1 Administrative Topic (see Note)
Type Code*
Describe activity to be performed Conduct of Operations N R The RO Candidate is given OSP-RCS-C101, the RPV Heatup Surveillance and asked to review it for any data that may be out of limits Conduct of Operations M R The RO Candidate is given data and asked to determine the time to change load for the Main Turbine Equipment Control P R The RO Candidate is given the task of determining the clearance boundary for work associated with replacement of a pipe coupling located downstream of FPC-P-1A Radiation Control M R The RO Candidate is given data for his personal dose and told he is to perform work that is in a High Radiation Area. The candidate has to calculate his maximum stay time Emergency Procedures/Plan NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.
- Type Codes & Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)
(N)ew or (M)odified from bank ( 1)
(P)revious 2 exams ( 1; randomly selected)
ES-301 Administrative Topics Outline Form ES-301-1 Facility: Columbia Generating Station Date of Examination: October 2009 Examination Level: RO SRO Operating Test Number: 1 Administrative Topic (see Note)
Type Code*
Describe activity to be performed Conduct of Operations N R The SRO Candidate plant data and asked to determine if a planned entry into the Area Of Increased Awareness is allowed Conduct of Operations N R The SRO Candidate is given that a fire detection system is inoperable and while investigating that, the preaction system pipe is broke. Based on the location the candidate determines compensatory measures and then fill out a Fire Protection Impairment Notification Form Equipment Control N R The SRO Candidate is given the task of approving/reviewing a clearance order for RHR-P-3 and determine if discrepancies exist Radiation Control P R The SRO Candidate is given Offgas system data and determines if actions are required Emergency Procedures/Plan M R The SRO Candidate is tasked with classifying an event and filling out a CNF after Simulator Scenario #3 NOTE: All items (5 total) are required for SROs. RO applicants require only 4 items unless they are retaking only the administrative topics, when all 5 are required.
- Type Codes & Criteria:
(C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)
(N)ew or (M)odified from bank ( 1)
(P)revious 2 exams ( 1; randomly selected)
ES-301 Control Room/In-Plant Systems Outline Form ES-301-2 Facility: COLUMBIA GENERATING STATION Date of Examination: October 2009 Exam Level: RO SRO-I SRO-U Operating Test No.: 1 Control Room Systems@ (8 for RO); (7 for SRO-I); (2 or 3 for SRO-U, including 1 ESF)
System / JPM Title Type Code*
Safety Function
- a. Start RRC-P-1B at Power (LO001681)
M, A, S 1
R / SRO-I
- b. Containment De-Inerting (LO001682)
D, EN, S 5
R / SRO-I
- c. Restart RFW-P-1A (Quick Restart) (LR000131)
N, L, S 2
R
- d. Parallel DG-1 with SM-7 (LO001684)
N, A, EN, L, S 6
R / SRO-I
- e. Pull fuses to close an open SRV (LO001683)
N, S 3
R / SRO-I
- f. Start RHR-A in SP Cooling, SW-V-12A fails to Auto Open (LO001686)
D, A, S 8
R / SRO-I
N, S 7
R / SRO-I
- h. Secure SGT Following Auto Initiation with FAZ Reset (LR000222)
D, EN, L, S 9
R / SRO-I In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
- i. Prevent a RCIC High Exhaust Pressure Trip (LR001505)
D, E, L, R 4
R / SRO-I
- j. Respond to Control Room HVAC High Radiation Level in One Remote Air Intake (LO001595)
D, P, A, E, R 9
R / SRO-I
D, P, A, R 7
R / SRO-I
All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all 5 SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
- Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path (C)ontrol room (D)irect from bank (E)mergency or abnormal in-plant (EN)gineered safety feature (L)ow-Power / Shutdown (N)ew or (M)odified from bank including 1(A)
(P)revious 2 exams (R)CA (S)imulator 4-6 / 4-6 / 2-3 9 / 8 / 4 1 / 1 / 1
- / - / 1 (control room system) 1 / 1 / 1 2 / 2 / 1 3 / 3 / 2 (randomly selected) 1 / 1 / 1 Actual JPM count:
(A) - 5/5 (C) - None (D) - 6/6 (E) - 3 /3 (EN) - 3/3 (L) - 4/3 (N) (M) - 6/6 (P) - 2/2 (R) - 3/3 (S) - 8/7