Operating Test Comments Systems JPM D:

Step 9 is critical and says start 2/3B Clean Demin pump. Must start 2/3A Clean Demin pump since 2/3B is OOS. RE: Stay as is since 2/3A Clean Demin pump is OOS. MUST start 2/3B pump!

Why isnt Step 11 critical, since applicant is required to open a valve and maintain level? RE: Not critical since already putting water into Hxer.

Systems JPM I How do you procedurally restore from this condition? RE: Will have to contact Ops Rep. May require procedure change!

Admin JPM A-N-4-R: Replaced JPM based on comments from outline review and Admin JPM A-N-4-S possible repetition with applicants audit exam.

Admin JPM A-N-2-S: Will applicant have access to a computer to do this JPM or do we want to prohibit computer use? RE: There will be no access to computer allowed to perform this JPM.

Scenario N-2:

Scenario needs to be improved.

Event #3 move to event #1, EDG running loaded for ST then lose EDGCWP. More challenging. RE: Completed!

Event #2: Lose CRD pump flow, must adjust flow controller before starting standby pump. RE: There will be no change to actions for a pump trip or filter clogging. Keep as is.

Events 5 & 6: Too similar. Will replace one or both with events from spare scenario. RE: Replaced Event 5.

Scenario N-2 will be moved to spare position and retitled N-4.

Scenario N-4 will be retitled to N-2 and will be used during exam.

The following comments were made during onsite validation week and were incorporated as follows:

Systems JPM B:

Add procedure step designators in JPM so examiner can follow along with procedure steps.

Break up cue after Step 4 and add second cue after Step 5.

Add note that I.8.g step to be N/Ad.

Systems JPM E:

Step 11, change panel location from 4 to 5!

Systems JPM F:

Cue after Step 3; Data sheet 1A not Data sheet 1.

Systems JPM G:

Step 2: Change Channel 4 to Drive Control Ch A.

Must setup simulator such that Drive Control CH A display window reads 9510+3.

Admin JPM A-N-1-R Need photo of CST level indicators in lieu of using panel indicators.

Scenario 1:

On Switching Orders provided to applicants, need to change breaker designator to match Scenario step, ie; change breaker to L302.

Major: Add contingency step since crew may cross-connect Bus 28 with Bus 29 which will result in Bus 29 tripping. Allow crew to recover Bus 29.

Scenario 2:

Event 2: Operator will be in room so dont need to wait 2 minutes to give cue.

Event 4: Add annunciator 902-5, F-2 to list of annunciators received.

Scenario 3:

Event 2: Add actions for SRO to reference DOA 6500-10. Also add actions for placing 2A Condensate/Booster pump in PTL.

Event 4: Role play @ bottom of page, QNE will work on rod move sheet.

Scenario 4:

Event 3: Contingency for TS call at end of scenario AND delete contingent TS.

Event 6: Add reference for TS 3.4.1 Condition B also!

Event 8: Trigger 17 will automatically be initiated on Scram.

I decided to use Scenario #4 in lieu of Scenario #2 for examination purposes.

Scenario #2 will be used as the spare scenario and retitled Scenario 4. Scenario 4 will be retitled to Scenario 2.