I
'KI ! ý Chawla, Mahesh From:
John Ellegood C3 Sent:
Monday, April 13, 2009 9:08 AM To:
Robert Lerch; Mahesh Chawla
Subject:
FW: MONITORING WELL TRITIUM RESULTS FROM 4-10-09 SAMPLING EVENT Attachments:
Copyof Palisades Monitoring Well Records 4-10-09.xls; Map of Palisades Monitoring Wells.pdf From: MALONE,, DANIEL G [1]
Sent: Saturday, April 11, 2009 11:49 AM To: John Ellegood
Subject:
FW: MONITORING WELL TRITIUM RESULTS FROM 4-10-09 SAMPLING EVENT From: DEHN, ERIC R Sent: Saturday, April 11, 2009 8:22 AM To: MALONE, DANIEL G; Shewmaker, Todd E; Arnone, Charles F Cc: SAVAGE, MARK A; Pink, Paul; OVERWAY, STEVEN S; Miller, Jarrod J
Subject:
MONITORING WELL TRFITUM RESULTS FROM 4-10-09 SAMPLING EVENT Monitoring Wells MW-2, MW-3, MW-4, MW-7 and MW-1 1 were sampled on 4-10-09 as a follow-up from the 4-6-09 sampling event due to the increasing trend of tritium activity in MW-3.
Results from 4-10-09 were; MW-2 641 pCi/L (MDA was 526 pCi/L)
MW-3 60,232 pCi/L MW-4 <MDA MW-7 < MDA MW-11 < MDA Attached is the updated graph for MW's - 2, 3, and 11, and a map of the monitoring well locations.
Please let me know if there are any questions.
Eric
TABLE 1 MONITORING WELL PURGING DATA JANUARY 14, 2008 T
C -A rUC NUCLEAR POWER STATION Tritium COVERT, MI Tritium Tritium (pCi/1)
(pci/1)
(pCi/L)
Palisades Palisades Lab Palisades Lab MW-MW-2 Lab MW-3 11 Date 12/13 /2007 01/14/2008 01/28/2008 02/11/2008 02/25/2008 03/10/2008 03/24/2008 4/7/2008 04/21/2008 05/05/2008 05/19/2008 06/02/2008 06/16/2008 06/30/2008 07/14/2008 07/28/2008 08/11/2008 08/26/2008 09/08/2008 09/22/2008 10/06/2008 10/22/2008 11/3/2008 11/17/2008 11/24/2008 12/1/2008 12/08/2008 12/15/2008 12/29/2008 01/12/2009 01/26/2009 02/09/2009 02/23/2009 03/09/2009 03/23/2009 1,150 34,581
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA 1,392 1,621 1,184 1,520 1,540 1,955 1,440 1,800 2,410 1,006 1,380
<MDA
<MDA 848 1,065 521 669
<MDA
<MDA 965 947
<MDA
<MDA 1221 773 9,380 19,331 42,903 16,735 13,262 11,100 7,616 4,935 9,030 8,435 1,935 9,964 3,500 639 884 3,419 2,678 1,254 3,453 2,500 3,397 13,138 19,671 20,339 4,733 5,654 934 7,920 10353 2,153 755 7,731 3,950 20,463 39,631 592 2205 11,812
<MDA 15,116
<MDA
<MDA
<MDA 5,480 7,773
<MDA 8,926
<MDA
<MDA
<MDA
<MDA
<MDA
<MDA 2854
<MDA
<MDA 04/06/2009 <MDA CRA Copy of Palisades Monitoring Well Records 4-10-09.xls
Chart Data
.,1 E
it IV W-V I\\L, ---
-W
-1
,/
M - ~ /
',Sý lb\\_
QVi Q
i C
Z\\
(8
\\
I
\\NW-pl'/
-M
-l~/
W3~
Page 1