June 21, 2010 Mr. Russell J. Bell, Director New Plant Licensing Nuclear Generation Division Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708
SUBJECT:
RESPONSE TO NUCLEAR ENERGY INSTITUTE LETTER ON NUCLEAR REGULATORY COMMISSION PLANS TO AMEND REGULATIONS RELATED TO INSPECTION TEST ANALYSIS ACCEPTANCE CRITERIA MAINTENANCE
Dear Mr. Bell:
By letter dated April 29, 2010 (Agencywide Documents Access and Management System Accession No. ML101300103), the Nuclear Energy Institute (NEI) submitted a letter to the U.S. Nuclear Regulatory Commission (NRC) to provide industry feedback on NRC staff plans and proposals to amend the regulations to include new requirements related to ITAAC maintenancethe period between the inspection, test, analysis, and acceptance criteria (ITAAC) closure and the NRC finding under Title 10 of the Code of Federal Regulations (10 CFR) 52.103(g) that the acceptance criteria in the combined license are met.
In your letter, you acknowledged the opportunities provided by the NRC staff in public meetings on March 5 and March 25, 2010, to discuss the draft rule language under development.
However, you reiterated your belief, as stated in those meetings, that new rulemaking at this time to address ITAAC maintenance was unnecessary for the following reasons:
the sufficiency of existing requirements in 10 CFR 52.99, Inspection during Construction, on ITAAC closure; 10 CFR 52.6, Completeness and Accuracy of Information; and 10 CFR 52.103(g) on the Commission finding that all acceptance criteria in the combined license are met ongoing efforts of the industry and NRC staff (staff) to develop guidance on ITAAC maintenance the lack of experience indicating a need for new requirements in this area You further stated that both the industry and the staff have long recognized the need for additional guidance related to ITAAC maintenance. To that end, NEI submitted a draft Revision 4 to NEI 08-01, Industry Guideline for ITAAC Closure Process under 10 CFR Part 52, on May 11, 2010, which includes guidance on ITAAC maintenance issues.
The NRC has already endorsed NEI 08-01, Revision 3, issued January 2009, via Regulatory Guide (RG) 1.215, Guidance for ITAAC Closure under 10 CFR Part 52.
R. Bell You stated your belief that ITAAC maintenance issues can be effectively addressed by the industry guidance ultimately endorsed in NRC RG 1.215.
As the NRC staff stated in the March public meetings, the staff does not agree that rulemaking on ITAAC maintenance is unnecessary. In general, the staff believes that rulemaking is necessary to ensure that the NRC has sufficient information, in light of new information developed or identified after the ITAAC closure notification under 10 CFR 52.99(c)(1), to complete all of the activities necessary for the Commission to make a finding on ITAAC. In addition, the rulemaking is necessary to ensure that interested persons have access to information on ITAAC at a level of detail sufficient to address the threshold for requesting a hearing, as specified in the Atomic Energy Act, Section 189.a(1)(B) - at least until the opportunity to request a hearing on ITAAC has passed.
Your letter highlighted some of your concerns with the staffs preliminary draft proposed rule language and included an attachment with specific comments on the staffs proposal as discussed at the March 25, 2010, public meeting. The staff appreciates the early feedback on the preliminary draft proposed rule language that NEI and other stakeholders provided during the March 2010 public meetings. As indicated in those meetings, the staff was not seeking formal comment on the proposed rule text at that time. The purpose of the public meetings was to engage interested stakeholders in a discussion of the draft proposed rule language and to gain information on the possible effects and consequences of the preliminary draft rule language that would inform the staffs development of the draft proposed rule to be presented to the Commission for its consideration. The staff believes the two public meetings served the intended purpose and that the draft proposed rule to be provided to the Commission will reflect NRC staff consideration of much of the information received during the meetings. Therefore, we are not providing a point-by-point response to your written comments at this time. Instead we request that, once the NRC publishes the proposed rule in the Federal Register for public comment, you evaluate the proposed rulemaking and resubmit those written comments from your April 29, 2010 letter that NEI believes are applicable to the published proposed rule. At that time, the NRC will address NEIs comments, as part of the NRCs response to all of the comments received by the NRC on the proposed rule.
R. Bell If you have any questions or comments regarding this matter, please contact Ms. Nanette Gilles by telephone at (301) 415-1180 or via e-mail at Nanette.Gilles@nrc.gov.
Sincerely,
/RA FAkstulewicz for/
David B. Matthews, Director Division of New Reactor Licensing Office of New Reactors Project No. 689 cc: See next page
If you have any questions or comments regarding this matter, please contact Ms. Nanette Gilles by telephone at (301) 415-1180 or via e-mail at Nanette.Gilles@nrc.gov.
Sincerely, David B. Matthews, Director Division of New Reactor Licensing Office of New Reactors Project No. 689 cc: See next page DISTRIBUTION:
Public NRCA R/F NGilles, NRO ELibby, NRO WBurton, NRO GMizuno, OGC MKowal, NRO RidsNroDnrlNrga RidsNroDnrl RidsNroDcip OgcMailCenter ADAMS Accession Number: ML101590526 NRO-002 OFFICE PM:DNRL/NRCA LA:DNRL/NRCA OGC BC:DNRL/NRCA NAME NGilles TWade GMizuno WBurton DATE 06/14/10 06/15/10 06/21/10 06/15/10 OFFICE DD:DCIP D:DNRL NAME GTracy (MShuaibi for)
DMatthews (FAkstulewicz for)
DATE 06/16 /10 06/21/10 OFFICIAL RECORD COPY
EXTERNAL DISTRIBUTION LIST FOR DCWG-ALL DCWG - Combined (All)
(Revised 05/12/2010) cc:
Mr. Ray Aycock Mr. Eugene S. Grecheck Field Supervisor Vice President U.S. Fish and Wildlife Service Nuclear Support Services Mississippi Ecological Services Office Dominion Energy, Inc.
6578 Dogwood View Parkway 5000 Dominion Blvd.
Jackson, MS 39213 Glen Allen, VA 23060 Mr. Richard L. Baker Mr. Jay M. Gutierrez Bechtel Power Corporation Morgan, Lewis & Bockius, LLP 5275 Westview Drive 1111 Pennsylvania Avenue, NW Frederick, MD 21703-8306 Washington, DC 20004 Scott Bond Ms. Sophie Gutner Callaway Plant P.O. Box 4646 P.O. Box 620 Glen Allen, VA 23058 Fulton, MO 65251 Mr. Brian Hastings Ms. Michele Boyd Public Utility Commission Legislative Director William B. Travis Building Energy Program P.O. Box 13326 Public Citizens Critical Mass Energy 1701 Noth Congress Avenue and Environmental Program Austin, TX 78701-3326 215 Pennsylvania Avenue, SE Washington, DC 20003 Mr. Adam C. Heflin Senior Vice President and Ms. Cindy Brizes Chief Nuclear Officer U.S. Department of Energy AmerenUE/Callaway Plant P.O. Box A P.O. Box 620 Aiken, SC 29802 Fulton, MO 65251 Mr. Barton Z. Cowan, Esquire Mr. Ronald Kinney Eckert Seamans Cherin & Mellott, LLC South Carolina DHEC 600 Grant Street, 44th Floor 2600 Bull Street Pittsburgh, PA 15219 Columbia, SC 29201 Director Dr. Regis A. Matzie Division of Compliance & Inspection Senior Vice President and Bureau of Radiation Control Chief Technology Officer Texas Department of State Health Services Westinghouse Electric Company 1100 West 49th Street 20 International Drive Austin, TX 78756-3189 Windsor, CT 06095 Page 1 of 5
DCWG - Combined (All)
Mr. Norris McDonald Mr. Robert E. Sweeney President IBEX ESI AAEA 4641 Montgomery Avenue 9903 Caltor Lane Suite 350 Ft. Washington, MD 20744 Bethesda, MD 20814 Dr. Masanori Onozuka Mr. Ed Wallace Mitsubishi Nuclear Energy Systems, Inc.
General Manager - Projects 1001 19th Street North, Suite 710 PBMR Pty LTD Arlington, VA 22201-5426 P. O. Box 9396 Centurion 0046 Dr. C. Keith Paulson Republic of South Africa Mitsubishi Nuclear Energy Systems, Inc.
300 Oxford Drive, Suite 301 Mr. Gary Wright, Director Monroeville, PA 15146 Division of Nuclear Facility Safety Illinois Emergency Management Agency PBMR Pty. Limited 1035 Outer Park Drive Lake Buena Vista Building Springfield, IL 62704 1267 Gordon Hood Avenue PO Box 9396 Centurion 0046 Republic of South Africa Charles Peterson Pillsbury, Winthrop, Shaw & Pittman, LLP 2300 "N" Street, NW Washington, DC 20037 Mr. Ernest Reed Living Education Center for Ecology and the Arts P.O. Box 2612 Charlottesville, VA 22902 Mr. Tom Sliva 7207 IBM Drive Charlotte, NC 28262 Mr. David W. Sutherland Chesapeake Bay Field Office U.S. Fish and Wildlife Service 177 Admiral Cochrane Drive Annapolis, MD 21401 Page 2 of 5
DCWG - Combined (All)
Email alsterdis@tva.gov (Andrea Sterdis) amonroe@scana.com (Amy Monroe)
APAGLIA@Scana.com (Al Paglia)
APH@NEI.org (Adrian Heymer) awc@nei.org (Anne W. Cottingham) bevans@enercon.com (Bob Evans)
Bill.Jacobs@gdsassociates.com (Bill Jacobs)
Bill.Moore@luminant.com (Bill Moore)
BrinkmCB@westinghouse.com (Charles Brinkman) brock.degeyter@energyfutureholdings.com (Brock Degeyter)
Carellmd@westinghouse.com (Mario D. Carelli) carey.fleming@cengllc.com (Carey Fleming) chris.maslak@ge.com (Chris Maslak) ck_paulson@mnes-us.com (Keith Paulson) ckpaulson@aol.com (C.K. Paulson)
CumminWE@Westinghouse.com (Edward W. Cummins) cwaltman@roe.com (C. Waltman) david.hinds@ge.com (David Hinds) david.lewis@pillsburylaw.com (David Lewis)
DeLaBarreR@state.gov (R. DeLaBarre)
DJW@NEI.org (Doug Walters) donald.woodlan@luminant.com (Donald Woodlan) ecullington@earthlink.net (E. Cullington) eddie.grant@excelservices.com (Eddie Grant) erg-xl@cox.net (Eddie R. Grant) frank_quinn@comcast.net (Frank Quinn)
Fred.Madden@luminant.com (Fred Madden) gcesare@enercon.com (Guy Cesare) gedgar@morganlewis.com (George Edgar)
GovePA@BV.com (Patrick Gove) gwcurtis2@tva.gov (G. W. Curtis) gzinke@entergy.com (George Alan Zinke) hickste@earthlink.net (Thomas Hicks) ian.c.rickard@us.westinghouse.com (Ian C. Richard) james.beard@gene.ge.com (James Beard)
JCaldwell@luminant.com (Jan Caldwell) jeff.simmons@energyfutureholdings.com (Jeff Simmons) jerald.head@ge.com (Jerald G. Head) jgutierrez@morganlewis.com (Jay M. Gutierrez) jim.riccio@wdc.greenpeace.org (James Riccio) jim@ncwarn.org (Jim Warren) jin_chung@mnes-us.com joel.Friday@ge.com (Joel Friday)
John.Conly@luminant.com (John Conly)
Page 3 of 5
DCWG - Combined (All) john.elnitsky@pgnmail.com (John Elnitsky)
John.O'Neill@pillsburylaw.com (John O'Neill)
Joseph_Hegner@dom.com (Joseph Hegner) joseph_tapia@mnes-us.com (Joseph Tapia) junichi_uchiyama@mnes-us.com (Junichi Uchiyama) karen@seedcoalition.org (Karen Hadden)
KSutton@morganlewis.com (Kathryn M. Sutton) kwaugh@impact-net.org (Kenneth O. Waugh) lchandler@morganlewis.com (Lawrence J. Chandler) lois@ieer.org (Lois Chalmers)
Marc.Brooks@dhs.gov (Marc Brooks) maria.webb@pillsburylaw.com (Maria Webb) marilyn.kray@exeloncorp.com mark.beaumont@wsms.com (Mark Beaumont)
Marvin.Smith@dom.com (Marvin L. Smith) masanori_onozuka@mnes-us.com (Masanori Onozuka) masayuki_kambara@mhi.co.jp (Masayuki Kambara) matias.travieso-diaz@pillsburylaw.com (Matias Travieso-Diaz) maurerbf@westinghouse.com (Brad Maurer) mbowling@numarkassoc.com (Marty Bowling) media@nei.org (Scott Peterson) mgiles@entergy.com (M. Giles) mike.blevins@luminant.com (Mike Blevins) mike_moran@fpl.com (Mike Moran) mlucas3@luminant.com (Mitch Lucas)
MSF@nei.org (Marvin Fertel) mwetterhahn@winston.com (M. Wetterhahn) nirsnet@nirs.org (Michael Mariotte)
Nuclaw@mindspring.com (Robert Temple) patriciaL.campbell@ge.com (Patricia L. Campbell) paul.gaukler@pillsburylaw.com (Paul Gaukler)
Paul@beyondnuclear.org (Paul Gunter) pshastings@duke-energy.com (Peter Hastings) rbird1@luminant.com (Bobby Bird) rclary@scana.com (Ronald Clary)
REB@NEI.org (Biff Bradley)
Rebecca.Smith-Kevern@nuclear.energy.gov (Rebecca Smith-Kevern)
RJB@NEI.org (Russell Bell) robert.kitchen@pgnmail.com (Robert H. Kitchen) sandra.sloan@areva.com (Sandra Sloan) sfrantz@morganlewis.com (Stephen P. Frantz) shinji_kawanago@mnes-us.com (Shinji Kawanago) sid.kere@dom.com (Sid Kere) stephan.moen@ge.com (Stephan Moen) steven.hucik@ge.com (Steven Hucik)
Page 4 of 5
DCWG - Combined (All) tgilder1@luminant.com (Tim Gilder) tkkibler@scana.com (Tria Kibler) tom.miller@nuclear.energy.gov (Thomas P. Miller) tomccall@southernco.com (Tom McCallum)
Tony_Banks@dom.com (Tony Banks) trsmith@winston.com (Tyson Smith)
Vanessa.quinn@dhs.gov (Vanessa Quinn) vijukrp@westinghouse.com (Ronald P. Vijuk)
Wanda.K.Marshall@dom.com (Wanda K. Marshall) wayne.marquino@ge.com (Wayne Marquino) whorin@winston.com (W. Horin)
Page 5 of 5