Text

Schedule DSA October 2003 Page 1 of 2 TENNESSEE VALLEY AUTHORITY DIRECT SERVICE POWER RATE--SCHEDULE DSA (October 2003)

Availability This rate shall apply to the firm electric power requirements of a customer that takes service directly from TVA and that has a contract demand of 5,000 kW or less.

Base Charges

1.

If (a) the higher of (i) the customer's currently effective contract demand, if any, and (ii) its highest billing demand during the latest 12-month period is not more than 50 kW and (b) customer's monthly energy takings for any month during such period do not exceed 15,000 kWh:

Customer Charge:

$8.15 per delivery point per month Energy Charge:

6.409¢ per kWh per month

2.

If (a) the higher of (i) the customer's currently effective contract demand and (ii) its highest billing demand during the latest 12-month period is greater than 50 kW but not more than 1,000 kW or (b) the customer's billing demand is less than 50 kW and its energy takings for any month during such period exceed 15,000 kWh:

Customer Charge:

$8.15 per delivery point per month Demand Charge:

First 50 kW of billing demand per month, no demand charge Excess over 50 kW of billing demand per month, at $9.46 per kW Energy Charge:

First 15,000 kWh per month at 6.409¢ per kWh Additional kWh per month at 3.215¢ per kWh

3.

If the higher of (a) the customer's currently effective contract demand and (b) its highest billing demand during the latest 12-month period is greater than 1,000 kW:

Customer Charge:

$8.15 per delivery point per month Demand Charge:

First 1,000 kW of billing demand per month, at $9.42 per kW Excess over 1,000 kW of billing demand per month, at $10.37 per kW, plus an additional

$10.37 per kW per month for each kW, if any, of the amount by which the customer's billing demand exceeds the higher of 2,500 kW and its contract demand Energy Charge:

3.215¢ per kWh per month

Schedule DSA October 2003 Page 2 of 2 Adjustment The base demand and energy charges shall be increased or decreased in accordance with the current Adjustment Addendum published by TVA. (In addition, such charges shall be increased or decreased to (a) correspond to increases or decreases determined by TVA in the value of the hydro-generation benefit allocated to residential consumers or (b) ensure that (i) TVA does not pay out more in hydro-allocation credits for sales to residential consumers than it receives in hydro-allocation debits for sales to other consumers or (ii) TVA does not receive more in such debits for sales to other consumers than it pays out in such credits for sales to residential consumers.)

Determination of Demand TVA shall meter the demands in kW of all customers having loads in excess of 50 kW. The metered demand for any month shall be the highest average during any 30-consecutive-minute period beginning or ending on a clock hour of the month of the load metered in kW. The measured demand for any month shall be the higher of the highest average during any 30-consecutive-minute period of the month of (a) the load metered in kW and (b) 85 percent of the load in kVA plus an additional 10 percent for that part of the load over 5,000 kVA, and such measured demand shall be used as the billing demand, except that the billing demand for any month shall in no case be less than 30 percent of the higher of the currently effective contract demand and the highest billing demand established during the preceding 12 months.

Minimum Bill The monthly bill under this rate schedule shall not be less than the sum of (a) the base customer charge, (b) the base demand charge, as adjusted, applied to the customer's billing demand, and (c) the base energy charge, as adjusted, applied to the customer's energy takings; provided, however, that, under 2 of the Base Charges, the monthly bill shall in no event be less than the sum of (a) the base customer charge and (b) 20 percent of the portion of the base demand charge, as adjusted, applicable to the second block (excess over 50 kW) of billing demand, multiplied by the higher of the customer's currently effective contract demand and its highest billing demand established during the preceding 12 months.

Single-Point Delivery The charges under this rate schedule are based upon the supply of service through a single delivery and metering point, and at a single voltage. If service is supplied to the same customer through more than one point of delivery or at different voltages, the supply of service at each delivery and metering point and at each different voltage shall be separately metered and billed.