W3F1-2010-0031, 180-Day Steam Generator Tube Inspection Report for 16th Refueling Outage
| ML101370228 | |
| Person / Time | |
|---|---|
| Site: | Waterford (NPF-038) |
| Issue date: | 05/13/2010 |
| From: | Steelman W Entergy Nuclear South, Entergy Operations |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| W3F1-2010-0031 | |
| Download: ML101370228 (44) | |
Text
Etergy Entergy Nuclear South Entergy Operations, Inc.
17265 River Road Killona, LA 70057-3093 Tel 504 739 6685 Fax 504 739 6698 wsteelm@entergy.com William J. Steelman Acting Licensing Manager Waterford 3 W3F1-2010-0031 May 13, 2010 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
SUBJECT:
180-Day Steam Generator Tube Inspection Report for the 1 6 TH Refueling Outage Waterford Steam Electric Station, Unit 3 Docket No. 50-382 License No. NPF-38
Dear Sir or Madam:
Attached is the 180-Day RF1 6 Steam Generator Tube Inspection Report for Entergy Operations, Inc.(EOI) Waterford Steam Electric Station Unit 3. This report is being submitted in accordance with Technical Specification 6.9.1.5 and provides the complete results of Refueling Outage 16 Steam Generator Tube Inspection.
There are no new commitments contained in this letter.
Please contact William J. Steelman at (504) 739-6685 if you have questions regarding this information.
/
Sincere WJS/RJP/ssf Attachments 1.
2.
180-Day Steam Generator Tube Inspection Report for the 1 6 TH Refueling Outage Additional Tables Relative to the 1 6 TH Refueling Outage Steam Generator Tube Inspection Report F~ocI
W3F17-2010-0031 Page 2 cc:
Mr. Elmo E. Collins, Jr.
Regional Administrator U. S. Nuclear Regulatory Commission Region IV 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125 NRC Senior Resident Inspector Waterford Steam Electric Station Unit 3 P.O. Box 822 Killona, LA 70066-0751 U. S. Nuclear Regulatory Commission Attn: Mr. N. Kalyanam Mail Stop O-07D1 Washington, DC 20555-0001 Wise, Carter, Child & Caraway ATTN: J. Smith P.O. Box 651 Jackson, MS 39205 Louisiana Department of Environmental Quality Office of Environmental Compliance Surveillance Division P. O. Box 4312 Baton Rouge, LA 70821-4312 American Nuclear Insurers Attn: Library Town Center Suite 300S 29th S. Main Street West Hartford, CT 06107-2445
)
To W3F1-2010-0031 180-Day Steam Generator Tube Inspection Report for the 1 6 TH Refueling Outage to W3F1-2010-0031 Page 1 of 14 RF16 180-Day Special Report Waterford 3 began RF16 with 8031 tubes in service in SG31 and 8133 tubes in service in SG32. Waterford 3 (WF3) Technical Specification (TS) 6.9.1.5 requires Entergy Operations to submit a 180 day report to the NRC that outlines the details of the steam generator (SG) tubing inspections that were performed during the reporting period. The report shall include:
6.9.1.5 A. The scope of inspections performed on each steam generator.
B. Active degradation mechanisms found.
C. Nondestructive examination techniques utilized for each degradation mechanism.
D. Location, orientation (if linear), and measured sizes (if available) of service induced indications.
E. Number of tubes plugged during the inspection outage for each active degradation mechanism.
F. Total number and percentage of tubes plugged to date.
G. The results of condition monitoring, including the results of tube pulls and in-situ testing and assessment of accident-induced leakage from all tubesheet indications.
H. Effective plugging percentage for all plugging in each generator.
Reference:
W3F1-2006-0070 dated 12-20-06 to U.S. NRC, Entergy Actions to Address RF14 Batwing Failures [ADAMS Accession Number ML063600109]
Attachment i to W3F1-2010-0031 Page 2 of 14 The operating period for this report includes one outage, a refueling inspection (RF16) in November 2009.
DESIGN The Waterford 3 Model 70 re-circulating steam generators were designed and fabricated by Nuclear Steam System Supplier Combustion Engineering (CE), Inc. in accordance with ASME Code,Section III NB for Class I vessels., The Waterford 3 steam generators each consist of 9,350 high temperature mill annealed INCONEL 600 U-tubes arranged in a one-inch inner diameter triangular pitch pattern representing 103,574 ft2 of heat transfer area. The U-tubes are 3/4" O.D. by 0.048" nominal wall thickness explosively expanded the full depth of the tube sheet (CE's Explansion Process) and welded to the primary cladding. The secondary tube bundle support structure consists of carbon steel eggcrates. The secondary supports are arranged in the following order:
- seven full horizontal eggcrate supports (01H - 07H, 01C - 07C)
- three horizontal partial eggcrates supports (08H-1 OH, 08C - 1OC)
- two anti-vibration straps (hot and cold batwings, BW1 and BW9) seven vertical straps (BW2 through BW8)
A. The Scope of Inspections Performed on Each Steam Generator.
The RF16 initial inspectionplan included:
- 1. 100% full length 0.600" bobbin examination (Rows 3 and up), 100%
0.600" bobbin examination of hot and cold leg straight sections in Rows 1 and 2
- 2. 100% +Point TM inspection of all eggcrate distorted signal indication (DSI) signals
- 3. 100% +Point inspection of all >2V dents at eggcrates (based on RF1 5 bobbin data)
- 4. 25% +Point inspection at dented diagonal bar and vertical strap locations >2V
- 5. 25% +Point inspection at freespan dings >5V
- 6. 100% hot leg TTS +Point inspection in each SG from 3 inches above to 12 inches below TTS to W3F1-2010-0031 Page 3 of 14
- 7. 100% Row 1 and 2 small radius U-bend +Point inspection in each SG using a mid-range +Point coil
- 8. 100% +Point inspection of all newly reported indications at diagonal bar and vertical straps (confirmation of mechanism)
- 9. 100% +Point inspection of historical %TW indications at diagonal bar and vertical straps
- 10. 100% +Point inspection special interest testing including;
- a. freespan signals unresolved in history or showing change
- b. any bobbin signal suggestive of tube wear at eggcrate structures
- c. any bobbin signal suggestive of axial degradation within the cold leg tubesheet region
- d. possible loose part (PLP) or loose part indication (LPI) signals reported either by bobbin or MPRC; all surrounding tube locations will also be inspected with MPRC
- e. Three tube deep peripheral cold leg top of tubesheet inspection with +Point coil from 3 inches above to 3 inches below top of tubesheet (PLP concern)
- 11. Plug visual examination
- a. 100% of the installed plugs were visually examined for signs of leakage.
- 12. Secondary side inspection and FOSAR The inspection. plan was developed to specifically address the areas of active degradation as well as areas expected to be affected based on recent industry experience as well as experience from the Spring 2008 Waterford 3 inspection and recent industry inspection results. These included:
- a. FOSAR of annulus region at the top of the tubesheet,
- b. Bottom up visual of the batwings in the central stay cavity.
- c. Video probe inspection of the batwings in the central stay cavity (45-degree), and
- d. Visual inspection of the steam drum region including moisture separators and feed ring.
to W3F1-2010-0031 Page 4 of 14 B. Active Degradation Mechanisms Found.
" Axial ODSCC at non-dented eggcrate intersections
" Longitudinal (axial) ODSCC at batwing and vertical strap structures
" Axial ODSCC in the hot leg sludge pile freespan region and expansion transition region
" Circumferential ODSCC at the hot leg TTS expansion transition
" Axial PWSCC at the hot leg expansion transition and expanded tubesheet region Circumferential PWSCC at the hot leg TTS expansion transition and expanded tubesheet region Wear at eggcrate, diagonal bar, and vertical strap structures
- Tube wear due to foreign objects
- Freespan axial ODSCC Batwing Degradation Flow Accelerated Corrosion of Feedring Distribution Box Tee Vent
. I to W3F1-2010-0031 Page 5 of 14 C. Nondestructive Examination Techniques Utilized for Each Degradation Mechanism.
Table C-1 Techniques Mechanism Location Probe Detection ETSS Sizing ETSS 27091.2 27091I.2 Loose Part Wear Bobbin Rev. 07Rev.0 Rev. 0 Rev. 0 96004.1 96004.1 Wear at Tube Support Structures (TSP & AVB)
Bobbin Rev.1 Rev.1 Rev. 12 Rev. 12 2401 3.1N/
Axial ODSCC at Dented Locations <5.0 Volts in the Freespan Bobbin Rev. 2 N/A Axial ODSCC in the Freespan, Sludge Pile and Eggcrate Support Bobbin 28413 N/A Plates without or with Dents <2.0 Volts Rev. 2 Axial ODSCC at Non-Dented EC and Sludge Pile Bobbin 96008.1 96008.1 Rev. 14 Rev. 14 96005.2 96005.2 Pitting in the Presence of Copper Bobbin Rev. 96Rev.9 Rev. 9 Rev. 9 Axial PWSCC at Dented Support Structures <2.0 Volts Bobbin 96012.1 N/A Rev. 12 Wear at Tube Support Structures (TSP & AVB)
+Point 96910.1 96910.1 Rev. 10 Rev. 10 21998.1 21998.1 Volurietric at Freespan Regions
+Point Rev. 41Rev.4 Rev. 4 Rev. 4 Axial ODSCC at Support Structures, Freespan, Sludge Pile and
+Point 21409.1 CEOG-1151 Tubesheet Crevice Rev. 6 Or Regression to W3F1-2010-0031 Page 6 of 14 Table C-1 Techniques (cont)
Mechanism Location Probe Detection ETSS Sizing ETSS Axial ODSCC in the Freespan, Sludge Pile and Eggcrate Support
+Point 28425 28432 Plates Rev. 2 Rev. 2 Circ. ODSCC at Expansion Transitions
+Point 21410.1 EPRI TR-107197 Rev. 6 Circ. PWSCC at Expansion Transition
+Point Rev. 70Rev.7 Rev. 7 Rev. 7 S
20511.1 20511.1 Axial PWSCC at Expansion Transition
+Point Rev. 80Rev.8 Rev. 8 Rev. 8 22842.1 CEOG-1151 Circ. ODSCC at Dented Support Plates
+Point Rev. 4 Or Rrs Rev. 4 Or Regression Axial PWSCC at Dented Locations
+Point 96703.1 96703.1 Rev. 17 Rev. 17 Axial ODSCC at Dented Support Locations
+Point 22401.1 22401.1 Rev. 4 Rev. 4 96511.2 96511.2 Axial/Circ. PWSCC at Low Row U-Bend Locations
+Point Rev. 165Re.1 Rev. 16 Rev. 16 Axial ODSCC at Low Row U-Bend Locations
+Point 21409.1 CEOG-1151 Rev. 6 Circ. ODSCC at Low Row U-Bend Locations
+Point 21410.1 EPRI TR-107197 Rev. 6 CEOG-1 151 - Use of this report for sizing SCC at dented intersections will be conservative as the measured flaw amplitude will include dent influence.
Attachment I to W3F1-2010-0031 Page 7 of 14 D. Location, Orientation (if linear), and Measured Sizes (if available) of Service Induced Indications.
See Attachment 2 for the following Tables Table D-1 "SG31 Service Induced Indications-Crack Indications-RF16" Table D-2 "SG32 Service Induced Indications-Crack Indications - RF16" Table D-3 "SG31 Service Induced Indications-Wear at Supports - RF16" Table D-4 "SG32 Service Induced Indications-Wear at Supports - RF16" Table D-5 "SG31&SG32 Service Induced Indications - Historical Volumetrics" to W3F1-2010-0031 Page 8 of 14 E. Number of Tubes Plugged During the Inspection Outage for Each Active Degradation Mechanism.
Table E-1 Tubes inservice prior to RFO16 8031 8133 Total Number of tubes previously removed from service
/
1319 1217 ReHopt LgTCnodida ese Aom RFOInit A
T 0
Hot Leg Top of Tubesheet Axial Indications (Above TTS) 0 0
Hot Leg Top of Tubesheet Circ. Indications (Above TTS) 0 0
Hot Leg Tube Sheet Axial Indications (Within Tubesheet) 2 0
Hot Leg Tube Sheet Circ. Indications (Within Tubesheet) 1 1
Tubesheet with Axial and Circumferential Indications 0
0 Tubesheet and Support Plate with Axial Indications, 0
0 Tubesheet Circumferential and Support Plate Axial Indications 0
0 Egg-Crate With Axial Indications 81 35 Batwings With Axial Indication 3
3 Batwings WithAxial Indication and Support Plate Axial Indication 0
0 Batwings With Volumetric Indication 0
0 Hot Leg Volumetric Indications 0
0 Cold Leg Volumetric Indications 0
0 Row 1 - Row 2 U-Bend Indications 0
0 Bobbin Percents => 40%
0 1
Customer Decision to Plug 1
0 Customer Decision Preventative (Row 1/Row 2) 0 0
Hot Leg Total Tubes Deplugged and Replugged - Post RFO16 0
0-Cold Leg Total Tubes Deplugged and Replugged - Post RFO16 0
0 Hobtal" Stabilies be Ruring R 8
0 Hot Leg 54" Stabilizers Installed During RFO16 0
1 Hot Leg 268" Stabilizers Installed During RFO16 0
0 Hot Leg 384" Stabilizers Installed During RFO16 0
0 Cold Leg 54" Stabilizers Installed During RFO16 0
0 Cold Leg 268" Stabilizers Installed During RFO16 0
0 Cold Leg 384" Stabilizers Installed During RIFO16 0
0 Total:Rep~air,t,o
, :-i-:*-.
i SG-*3.1
- ' *SG*32,..I Total Stabilizers Installed - RFO16 0
1 Total Tubes Plugged - Post RFO16 1407 1257 Total SG % Plugged - Post RFO16 15.05%
13.44%
Note: Above Tubesheet is all calls =>.01" above.
Note: Within Tubesheet is all calls =<.00".
See Attachment 2 for the following Tables Table E-2 "SG31 Plugging List - RF1 6" Table E-3 "SG32 Plugging List - RF1 6" to W3F1-2010-Q031 Page 9 of 14 F. Total Numberand Percentage of Tubes Plugged to Date.
Table F-1 WF3 Historical Plugging Year Outage EFPY SG31 SG32 Total Cum%
Cumulative Plugs Plugs Plug Plugging 1985 Pre-154 169 323 1.7 323 1986 RF01 1.01 0
0 0
1.7 323 1987 RF02 2.08 0
1 1
1.7 324 1989
'RF03 3.31 11 8
19 1.8 343 1991 RF04 4.55 161 161 322 3.6 665 1992 RF05 5.83 4
5 9
3.6 674 1994 RF06 7.15 4
2 6
3.6 680 1995 RF07 8.52 15 4
19 3.7 699 1997 RF08 9.90 29 26 55 4.0 754 1999 RF09 11.02
.12 10 22 4.2 776 2000 RF10 12.37 28 38 66 4.5 842 2002 RF11 13.70 26 10 36 4.7 878 2003 RF12 15.18 127 50 177 5.6 1055 2005 RF13 16.68 247 223 470 8.2 1525 2006 RF14 18.12 358 460*
818 12.5 2343 2008 RF15 19.41 143
- 51.
194 13.6 2536 2009 RF16 20.79 88 40 128 14.2 2664 Total Plugged to Date 1407 1257 2664 Percent Plugged to Date 15.05 13.44
- Includes tube plugged on one end to W3F1-2010-0031 Page 10 of 14 G. The Results of Condition Monitoring, Including the Results of Tube Pulls and In-situ Testing and Assessment of Accident-Induced Leakage from all Tubesheet Indications.
Waterford 3 did not perform any tube pulls and one in-situ test was required during RF16.
As part of Waterford 3's adherence to perform In-situ Screening in accordance with EPRI, TR-1 014983, "Steam Generator In-Situ Pressure Test Guidelines", Rev. 3, all indication identified were screened with one test required. The flaw was taken to 5600 psig pressure with zero leakage. The tube R18 C1 12 is located in SG# 1. The condition was entered into Entergy's corrective action program.
CR-WF3-2009-06592 Flaw found in SG #1 R18 C112 near 07H support requires screening and profiling for possible in-situ pressure testing. This flaw is inspected with the Appendix I technique of the SG Program Guidelines. In-situ testing is contingency for RF16 and can be completed under the SG Inspection and Repairs WO Based on the Waterford 3 RF16 inspection results and in-situ pressure testing, no tubes contained indications which represented a challenge to structural or leakage integrity and all condition monitoring requirements are satisfied. Structural and leakage integrity was established by analysis and through comparison of past in-situ testing results as well as by comparison of observed flaw parameters against the leaking testing thresholds established by EPRI TR-1014983 Steam Generator In-Situ Pressure Test Guidelines Rev 3.
No primary to secondary leakage is predicted for the eddy current indications observed at RF1 6 in the event of a postulated SLB event. The relative severity levels of the observed degradation was judged consistent with or bounded by the levels associated with the RF1 5 inspection, and recent inspections of similar CE SGs.
Only two indications were observed within the tubesheet region. Both were circumferential PWSCC, one in each SG. In SG31 the indication was located at approximately 14 inches below the top of tubesheet, had a maximum +Point amplitude of 0.84 volt in 300 kHz, and had an indicated arc length of 31 degrees. In SG32, the indication was located at the expansion transition, had a maximum +Point amplitude of 0.49 volt in 300 kHz; and had an indicated arc length of 32 degrees. Each indication was below the leakage threshold so the predicted accident induced leakage fr6m these tubesheet indications is zero gpm.
to W3F1-2010-0031 Page 11 of 14 Waterford 3 has a current Plant Specific Leakage limit of 0.375 gallons per minute for an "accident-induced leakage limit" and applies a reduction of 0.1 gallons per minute to this value to provide the basis for the approved tube leakage integrity criteria. The inspection requirements described in TS 6.5.9.c.1 applies an alternate repair criteria which utilized this reduction. The predicted leakage is zero, thus the accident-induced leakage limit is met.
During the Waterford RF1 6 steam generator tube inspection, no indications exceeding the structural integrity limits for either axial or circumferential degradation (i.e., burst integrity > 3 times normal operating primary to secondary pressure differential across SG tubes) were detected. Therefore, no tubes were identified to contain eddy current indications that could potentially challenge the tube integrity recommendations of NEI 97-06 Revision 2, "Steam Generator Program Guidelines". Similarly, all operational assessment structural and leakage integrity requirements are satisfied at EOC-1 7 for the degradation mechanisms observed at EOC-16:
One tube in SG31 was plugged due to data quality reasons associated with copper deposits. The location is R106 C148 at the 01H eggcrate location. A 1.21 volt (maximum) copper signal was reported from +Pt.
This signal was evaluated and the tube met the condition monitoring.,
criteria.
Foreign Obiect/Loose Parts Wear Examinations for loose parts were performed as planned..The PLP indications were re-examined and bounding MPRC exams were performed.
No new foreign object associated wear was reported at RF16.
Cold Leg Volumetric Indications At RF1 5, in SG31, one tube (R2 C156) was. reported with a volumetric signal just above the top of tubesheet. This location was also reported as a volumetric signal at RF14. At RF14, FOSAR showed no evidence of a PLP and the +Point eddy current data showed no evidence of a PLP. A PLP was likely adjacent to this tube at one point in time but is no longer present. At RF1 4 the indication was sized at 21 %TW and left in service.
The RF15 +Point amplitude is essentially equal to the RF14 value, and is sized at 26%TW. The RF16 +Point eddy current data again shows no evidence of a PLP. This indication was again left in service. There was no change in signal parameters between RF15 and RF16.
At RF1 5, in SG32 a volumetric signal (R1 04 C30) was reported the to W3F1-2010-0031 Page 12 of 14 approximate mid-span elevation between just above the 07H eggcrate. A review of the bobbin history'data shows no change in the signal since 1994. This signal is most likely attributed to a manufacturing artifact, such as a lap. The depth based on sizing with the +Point coil according to ETSS 21998.1 was 19%TW at RF15; there was no change in the signal response at RF16. This indication was left in service.
Secondary Side Inspections The secondary inspection was performed per the requirements of the Entergy procedure NOECP-257 "Steam Generator Secondary Side Inspections", which includes a full steam drum inspection and feedring.
Entergy committed to performing "augmented" examinations of the batwings. These inspections were completed during RF1 6.
The inspections were completed concurrently but were documented separately. The secondary side inspectionswere documented in WO-116193 and WO-1i16208. The augmented examinations were performed under WO-001 53097 and WO-00153098. The augmented examination results, were reviewed and evaluated by Engineering. The evaluated results are attached in the Corrective Action Program.
For SG31 the augmented inspection result is documented in CR-WF3-2006-03966 CA-0063.
For SG32 the augmented inspection result is documented in CR-WF3-2006-03966 CA-0064.
Summary results are stated:
CA-0063 Action This corrective action is to document the results of augmented inspections performed during Refuel 16 of the secondary side of the Steam Generator 31. The augmented inspections will include the upper batwing to wrapper bar welds, inspection of the stay cavity region, and foreign object search and retrieval (FOSAR) of the secondary side.
Summary, Response An inspection of Steam Generator #1 (SG 31) was performed during the Fall 2009 Refuel 16 (RF16) outage to determine if there were any changes in extent of condition or the critical variables that were the basis for the RF14 repair plan, Mid-Cycle 15 (PO 07-0 1) to W3F1-2010-0031 Page 13 of 14 and RF15 operational assessments. The visual inspections performed consisted of an upper batwing weld and wrap around bar inspection, diagonal 45 degree through-tube bundle inspection, a bottom-up inspection of the batwings in the stay cylinder region and a Foreign Object Search and Retrieval (FOSAR). All inspection results were satisfactory and met the established acceptance criteria. There were no changes to the expected extent of condition or the critical variables that were the basis for the Refuel-14 repair plan, Mid-Cycle 15 (PO 07-01) and Refuel-15 operational assessment. These assessments still remain valid and bounding.
Waterford 3 plans to replace both steam generators during RF1 7.
The full inspection. report is attached to the Corrective Action.
CA-0064 Action This corrective action is to document the results of augmented inspections performed during Refuel 16 of the secondary side of the Steam Generator 32. The augmented inspections will include the upper batwing to wrapper bar welds, inspection of the stay cavity region, and foreign object search and retrieval (FOSAR) of the secondary side.
Summary Response An inspection of Steam Generator #2 (SG32) was performed during the Fall 2009 Refuel 16 (RF16) outage to determine if there were any changes in extent of condition or the critical variables that were the basis for the mitigating actions taken in Refuel 14, Cycle 15 Operational Assessment, and Refuel 15. The visual inspections performed consisted of an upper batwing weld and wrap around bar inspection, diagonal 45? Through-Tube Bundle Inspection, a Bottom-Up Inspection of the batwings in the central stay cavity region, and a Foreign Object Search and Retrieval (FOSAR). All inspection results met the established acceptance criteria. There were no changes to the extent of condition or the critical variables that were the basis for the mitigating actions taken in RF14, Cycle 15 Operational Assessment, and RF15. Additionally, the assessments performed in RF14, the October 2007 Mid-Cycle 15 outage (P0-07-01), and RF15 remains valid and bounding.
Waterford 3 plans to replace both steam generators during RF1 7 (Spring 2011) outage.
The full inspection report is attached to the Corrective Action.
to W3F1-2010-0031 Page 14 of 14 Inspection per NOECP-257 "Steam Generator Secondary Side Inspections".
During the feed ring inspections of Steam Generator No".1 per NOECP 257 and W/O 116193 it was discovered that weld between the Elbow Tee Assembly and the feed ring distribution box is broken. The elbow tee assembly is completely broken off. The elbow tee assembly is visible and is resting between the outer shell of the steam generator and the shroud around the tubes., Discovery of missing Vent -Tee entered into the Corrective Action Program as CR-WF3-2009-06504.
The cause of the failure was determined to be Flow Accelerated Corrosion (FAC). As an extent of condition effort, SG32 was drained and re-examined.
NDE measurements were made of the distribution box and feed rings of both Steam Generators. The inspection results were entered into the Corrective Action Program under Condition, Reports CR-WF3-2009-06622 and CR-WF3-2009-06629. The conditions were evaluated by Engineering and Westinghouse. Operation of the SG with the missing vent tee was evaluated found to be acceptable for a cycle of operation. The issue remains in the Corrective Action Program as a Significantly Degraded Non-Conforming (SDNC) item. The missing vent tee was located in the down'comer region and retrieved. There was no contact with SG tubing..
A small sized screw (size M2 x3mm) from a communications belt was noted as missing and was assumed to be left in SG32.
The condition was entered into the corrective action program as condition report, CR-WF3-2009-06206. The condition was evaluated by Engineering and Westinghouse as acceptable for a cycle of operation.
FOSAR in each Steam Generator was completed in both the annulus region and the blow down tube lane. These inspections revealed no loose parts.
H. Effective Plugging Percentage for all Plugging in Each Generator.
Table H-1 Effective Plugging Percentage Generator
- Plugged
% Plugged SG31 1407 15.05%
SG32 1257 13.44%
To W3F1-2010-0031 Additional Tables Relative to the 16 TH Refueling Outage Steam Generator Tube Inspection Report to W3F1-2010-0031 1 of 26 Table D-1 SG31Service Induced Indications - Crack Indications - RF16 Count SG Row Col Volts Deg Ind Locn Inch1 Inch2 CrLen CrWid Ceg 1
31 7
13 0.14 101 SAI 01H
-0.70 0.18 0.32 48 2
31 28 18 0.25 104 SAI 03H 0.87 0.24 0.37 56 3
31 9
19 0.24 100 SAI 07H 0.54 0.28 0.33 50 4
31 13 23 0.29 89 SAI 03H 1.01 1.22 0.20 0.72 109 5
31 11 29 0.22 84 SAI 03H
-0.38 0.15 0.33 50 6
31 83 31 0.11 76 SAI 08H 0.79 0.27 0.31 47 7
31 93 31 0.16 138 SAI 02H 0.93 0.21 0.28 43 8
31 90 36 0.17 146 SAI 05H 0.94 0.24 0.39 59 9
31 60 38 0.24 61 SAI BW5
-0.93 0.39 0.31 47 10 31 62 40 0.16 92 SAI 05H 0.88 0.27 0.31 47 11 31 17 41 0.17 84 SAI 06H 0.90 0.38 0.29 45 12 31 59 41 0.11 81 SAI 07H 0.41 0.64 0.37 56 13 31 10 42 0.20 96 SAI 07H
- 0.59 0.90 0.28 43 14 31 5
43 0.33 92 SAI 06H 0.57 1.79 0.34 51 15 31 66 44 0.29 108 SAI 04H 0.86 0.29 0.44 67 16 31 66 44 0.11 83 SAI 05H 0.86 0.24 0.20 31 17 31 5
47 0.40 95 SAI 07H 0.84 0.45 0.29 45 18 31 6
50 0.21 96 SAI 05H
-0.49 0.18 0.29 45 19 31 88 50 0.22 93 SAI 03H 0.94 0.14 0.41 63 20 31 3
51 0.39 108 SAI 06H 0.88 0.70 0.31 47 21 31 88 52 0.23 99 SAI 07H
-0.17 0.17 0.27 42 22 31 104 52 0.19 103 SAI 07H1-
-0.12 0.24 0.53 80 23 31 5
55 0.37 109 SAI 07H
-0.63 0.37 0.32 48 24 31 79 55 0.38 94 SAI 07H
-0.45, 0.64 0.35 53 25 31 36 56 0.22 102 SAI 02H 0.99 0.15 0.38 58 26 31 36 56 0.18 109 SAI 04H 0.86 0.15 0.36 55 27 31 9
57 0.29 101 SAI 06H 0.63 0.58 0.32 48 28 31 19 57 0.09 68 SAI 04H 0.96 0.25 0.20 31 29 31 42 58 0.27 51 SAI 04H 0.96 0.18.
0.20 31 30 31 72 58 0.21 96 SAI 06H 0.91 0.36 0.28 43 31 31 88 58 0.16 159 SAI 05H 0.91 0.29 0.24 37 32 31 39 59 0.16 97 SAI 05H
-0.42 0.30 0.25 39 33 31 75 59 0.25 115 SAI 05H
-0.13 0.85 0.37 56 34 31 75 59 0.20 111 SAI 08H 0.92 0.45 0.26 40 35 31 99 59 0.22 123 SAI 01H 0.87 0.27 0.35 53 36 31 32 60 0.15 116 SAI 03H 0.88 0.35 0.33 50 37 31 35 61 0.14 60 SAI 04H 0.80 0.21 0.23 35 38 31 17 63 0.20 127 SAI 01H 0.14 0.23 0.42 64 39 31 70 64 0.11 115 SAI 07H
-0.44 0.15 0.32 48 40 31 53 67 0.25 93 SAI 08H 0.86 0.38 0.27 42 41 31 92 68 0.15 105 SAI 02H
-0.31 0.29 0.34 51 42 31 69 71 0.16 100 SAI 05H 0.39 0.17 0.33 50 43 31 52 74 0.14 130 SAI 02H 0.66 0.70 0.39 59 44 31 90 74 0.17 101 SAI 08H
-0.91 0.18 0.27 42 45 31 78 78 0.30 96 SAI 04H
.0.92 0.21 0.42 64 46 31 73 79 0.12 92 SAI 02H 0.81 0.34 0.53 80 47 31 85 83 0.18 136 SAI 03H 0.82 0.31 0.52 79 48 31 94 88 0.14 84 SAI TSH
-0.11 0.03 0.14 0.33 50 49 31 57 93 0.26 106 SAI 06H
-0.11 0.21 0.36 55 to W3F1-2010-0031 2 of 26 Table D-1 SG31Service Induced Indications - Crack Indications - RF16 Count SG Row Col Volts Deg Ind Locn Inch1 Inch2 CrLen CrWid Ceg 50 31 89 93 0.15 98 SAI TSH
-0.06 0.05 0.11 0.34
.51 51 31 65 97 0.13 96 SAI 06H 0.88 0.28 0.27 42 52 31 118 98 0.12 130 SAI 06H 0.84 0.15 0.37 56 53 31 67 99 0.19 90 SAI 07H
-0.45 0.36 0.28 43 54 31 67 99 0.31 70 SAI 07H 0.57 0.36 0.33 50 55 31 99 99 0.22 73 SAI 04H
-0.04 0.25 0.56 85 56 31 84 102 0.16 102 SAI 07H 0.09 0.15 0.26 40 57 31 95 103 0.15 66 SAI 06H 0.78 0.13 0.23 35 58 31 64 106 0.17 111 SAI 08H
-0.47 0.33 0.31 47 59 31 64 106 0.17 94 SAI 08H 0.11 0.10 0.34 51 60 31 64 106 0.32 101 SAI 08H 0.90 0.23 0.34 51 61 31 98 106 0.16 93 SAI BW3 0.97 1.09 0.24 0.27 42 62 31 68 108 0.17 85 SAI 07H 0.87 0.28 0.27 42 63 31 18 112 0.23 83 SAI 01H 0.07 0.28 0.49 76 64 31 18 112 0.10 163 SAI 01H 0.39 0.15 0.29 45 65 31 18 112 0.14 59 SAI 07H
-0.81 0.30 0.20 31 66 31 18 112 0.26 56 SAI 07H
-0.17 0.15 0.24 37 67 31 18 112 0.47 93 SAI 07H 0.51 0.80 0.31 47 68 31 51 113 0.87 19 SCI TSH
-13.67 0.23 0.19 29 69 31 27 115 0.21 105 SAI 01H 0.95 0.27 0.59 90 70 31 109 115 0.06 84 SAI 01H
-0.60 0.18 0.35 53 71 31 109 115 0.29 117 SAI 01H 0.54 0.41 0.36 55 72 31 6
116 0.24 119 SAI 01H
-0.18 0.37 0.40 61 73 31 120 116 0.15 112 SAI 04H 0.26 0.23 0.33 50 74 31 55 117 0.11 95 SAI 01H
-0.12 0.33 0.40 61 75 31 8
118 0.26 96 SAI 07H 0.44 0.73 0.32 48 76 31 80 118 0.17 91 SAI 06H 0.85 0.23 0.29 45 77 31 33 119 0.18 84 SAI 06H 0.84 0.38 0.23 35 78 31 6
122 0.14 108 SAI 01H
-0.65 0.25 0.36 55 79 31 18 122 0.20 88 SAI 07H
-0.46 0.25 0.23 35 80 31 66 122 0.16 105 SAI 04H
-0.73 0.10 0.33 50 81 31 41 123 0.11 65 SAI 06H 0.53 0.81 0.20 31 82 31 46 126 0.20 110 SAI 03H 0.22 0.43 0.21 32 83 31 53 127 0.20 92 SAI 06H 0.93 0.30 0.26
'40 84 31 73 129 0.23 79 SAI 04H
-0.51 0.35 0.27 42 85 31 16 130 0.19 65 SAI 07H
-0.64
-0.33 0.24 0.28 43 86 31 69 131 0.16 77 SAI 07H
-0.37 0.31 0.24 37 87 31 81 131 0.13 112 SAI 03H 0.87 0.33 0.42 64 88 31 14 134 0.27 91 SAI 07H
-0.68
-0.40 0.37 0.31 47 89 31 14 134 0.21 87 SAI 07H 0.82 1.08 0.40 0.23 35 90 31 54 134 0.16 69 SAI 07H 0.58 0.68 0.12 0.20 31 91 31 31
-0.78 0.46 0.20 31 93 31 119 137 0.28 51 SAI BW2
-0.82 0.21 0.24 37 94 31 4
140 0.39 85 SAI 07H 0.43 0.41 0.29 45 95 31 6
142 0.12 39 SAI 05H
-0.63
-0.44 0.26 0.26 40 96 31 36 144 0.20 104 SAI 07H 0.55 0.70 0.26 0.34 51 97 31 7
145 0.42 117 SAI 05H 0.10 0.42 0.42 0.39 59 98 31 24 156 0.16 52 SAI 07H 0.82 1.01 0.24 0.25 39 to W3F1-2010-0031 3 of 26 Table D-1 SG31 Service Induced Indications - Crack Indications - RF16 Count SG Row Col Volts Deg Ind Locn Inch1 Inch2.
CrLen CrWid Ceg 99 31 26 158 0.17 115 SAl 02H 0.45 0.71 0.45 0.40 61 to W3F1-2010-0031 4 of 26 Table D-2 SG32 Service Induced Indications - Crack Indications - RF16 Count SG Row Col Volts Deg Ind Locn Inch1 Inch2 CrLen CrWid Ceg 1
32 17 25 0.09 122 SAI 03H 0.64 0.14 0.36 55 2
32 67 33 0.09 5
SAI 02H 0.87 0.15 0.23 35 3
32 46 36 0.14 100 SAI 04H 0.94 0.20 0.46 71 4,
32 29 37 0.24 104 SAI BW5 0.77 1.02 0.25 0.34 51 5
32 9
39 0.29 91 SAI 03H 0.84 0.18 0.44 67 6
32 89 41 0.17 82 SAI 07H 0.64 0.27 0.24 37 7
32 34 42 0.21 68 SAI BW5
-0.66'
-0.27 0.29 0.22 34 8
32 74 44' 0.19 148 SAI 04H 0.88 0.20 0.31 47 9
32, 53 47 0.18 106 SAI 03H
-0.86 0.17 0.32 48 10 32 53 47 0.11 40 SAI 03H
-0.01 0.15 0.15 22 11 32 53 47 0.07 135 SAI 03H 0.84 0.10 0.19 29 12 32 31 55 0.12 79 SAI 06H
-0.33 0.18 0.23 35 13 32 93 67, 0.17 74 SAI 08H 0.86 0.20 0.25 39 14 32 112 68 0.24 68 SAI 08H 0.77 0.30 0.27 42 15 32 85 87 0.38 97 SAI 09H
-0.99 0.70 0.27 42 16 32 91 87 0.12 81 SAI 06H 0.74 0.23 0.24 37 17 32 85 97 0.15 79 SAI 06H 0.72 0.42 0.24 37 18 32 83 103 0.11 107 SAI 02H'
-0.68 0.19 0.34 51 19 32 68 104 0.20 82 SAI 01H
-0.54 0.19 0.38 58 20 32 70 104 0.12 116 SAI,'
04H 0.79 0.27 0.24 37 21 32 79 105 0.20 112 SAI 02H 0.55.
0.40 0.40 61 22 32 85 109 0.18 93 SAI 07H 0.92 0.40 0.37 56 23 32 30 114 0.20 99 SAI 06H 0.78 0.51 0.27 42 24 32 13 115 0.22 79 SAI 01H
-0.52 0.19 0.37 56 25 32 13 115 0.10 102 SAI 01H 0.13 0.16 0.34 51 26 32 89 117 0.12 110 SAI 02H
-0.11 0.25 0.33 50 27 32 77 119 0.17 93 SAI BW4 0.13 0.21 0.34 51 28 32 77 119 0.24 89 SAI BW4 0.68 0.64 0.35 53 29 32 38 120 0.49 23 SCI TSH
-0.21 0.05 0.26 0.21 32 30 32 91 123 0.21 127 SAI 03H
-0.79 0.17 0.38 58 31 32 61 127 0.17 124 SAI 04H 0.76 0.45
,0.29 45 32 32 73 127 0.05 76 SAI 02H 0.09 0.25 0.25 39 33 32 73 127 0.16 131 SAI
- 02H, 0.81 0.37 0.45 69 34 32 73 127 0.24 131 SAI 04H 0.72.
0.52 0.40 61 35 32 75 127 0.15 147 SAI 03H
-0.79 0.20 0.41 63 36 32 46 128 0.19 137 SAI 03H
-0.50 0.35 0.31 47 37 32 46 128 0.14 87 SAI 07H
-0.47 0.30 0.21 32
.38 32 14 132 0.21 56 SAI 07H
-0.16
.0.19 0.28 43 39 32 30 132 0.13 95 SAI.
06H 0.80 0.20 0.27 42 40 32 42 132 0.18 109 SAI 02H 0.11 0.15 0.40 61 41 32 42 132 0.14 127 SAI 02H 0.41 0.25 0.34 51 42 32 13 133 0.22 97 SAI 06H 0.41 0.24 0.28 43 43 32 29 135 0.19 89 SAI 06H 0.80 0.33 0.25 39 44 32 39 139 0.17 94 SAI 04H 0.61 0.18 0.31 47 45 32 30 144 0.16 113 SAI 02H 0.89 0.15 0.28 43 46 32 82 144 0.19 130 SAI 02H 0.76 0.13 0.39 59 47 32 31 149 0.05 113.
SAI 05H
-0.33 0.17 0.34 51 to W3F1-2010-0031 5 of 26 Table D-3 SG31 Service Induced Indications - Wear at Supports - RF16 Count SG Row Col Volts Deg Ind Per.TW Locn Inch1 1
31 20 4
0.13 0
PCT 7
01C 0.50 2
31 41 5
0.30 0
PCT 18 06H
-0.92 3
31 8
6 0.27 0
PCT 12 03H
.0.85 4
31 42 6
0.33 0
PCT 19 BW5
-0.37 5
31 5
7 0.25 0
PCT 8
-07H
-0.47 6
31 15, 9
0.28 0
PCT 12 03H 0.87 7
31 74 14 0.24 0
PCT 16 BW1
-1.95 8
31 74 14 0.47 0
PCT 23 BW4 0.94 9
31 19 15
.0.30 0
PCT 9
BW5
-0.95 10 31 19 15 0.29 0
- 9.
BW5 0.72 11 31 61 15 0.43 0
PCT 17 BW5
-0.83 12 31 61 15 0.19 0
PCT 9
BW5 0.31 13 31 61 15 0.34 0
PCT 14 BW5 1.06 14 31 61 15 0.93 0
PCT 28 BW6
-0.81 15 31 61 15 0.42 0
PCT 17 BW6 0.96 16 31 36 16 0.33 0
- PCT, 11 BW5 0.79 17 31 64 16 0.47
'0 PCT 13 BW5
-0.98 18 31 64 16 0.30 0
PCT 9
BW5 0.82 19 31 45 17 0.21 0
PCT 7
BW5
-0.89 20 31 45 17 0.34 0
PCT 11 BW5 0.86 21 31 36 18 0.32 0
PCT 10 BW5
-1.04 22 31 36 18 0.28 0
PCT 8
BW5 0.87 23 31 62 18 0.45 0
PCT 13 BW4 0.64 24 31 42 20 0.28 0
'PCT 9
BW5
-0.90 25 31 81 21 0.51 0
PCT _
24 08C 0.70 26 31 32 22 0.30 0
PCT 9
BW5
-0.86 27 31 78 22 0.35 0
PCT 13 BW5 0.78 28 31 78 22 0.35 0
- 13.
BW6 1.20 29 31 70 24 0.46 0
PCT 23 BW5
-0.85
- 30.
31 70 24 0.45 0
PCT 23 BW6 0.92 31 31 5
25 0.32 0
PCT 9
07H
-0.28 32 31 37 25 0.29 0
PCT 10 BW5
-0.79 33 31 37 25 0.18 0
PCT 6
BW5 0.03 34 31 37 25 0.29 0
PCT 10 BW5 0.89 35 31 19 27 0.28 0
PCT 8
BW5 0.78 36 31 77 27 0.27 0
PCT 19 BW4
-0.34 37 31 77 27 0.34 0
PCT 21 BW5
-1.18 38 31 77 27' 0.32 0
PCT 21 BW5 0.99 39 31 77 27 0.50 0
PCT 26
- BW6,
-0.84 40 31 77 27 0.36 0
PCT 22 BW6 0.90 41 31 50 28 0.21 0
PCT 7
BW5
-0.90 42 31 50 28 0.45 0
PCT 13 BW5 1.04 43 31 66 28 0.29 0
PCT 12 03C 0.18 44 31 105 29 0.22 0
PCT 10 BW7
-0.78 45 31 105 31 0.27 0
PCT 17 BW7
-0.66 46 31 105 31 0.28 0
, 18 04C 0.71 47 31 107 31 0.39 0
PCT' 15 BW7
-0.75 48 31 82 32 0.32 0
PCT 13 BW4 0.81 49 31 100 32 0.30 0
PCT 12 09H
-0.79 to W3F1-2010-0031 6 of 26 Table D-3 SG31 Service Induced Indications-Wear at Supports - RF16 Count SG Row Col Volts Deg Ind Per TW Locn Inch1 50 31 114 34 0.32 0
PCT 19 BW9 2.00 51 31 55 35 0.37 0
PCT 11
.BW4 0.69 52 31 61 35 0.42 0
PCT 12 BW5 0.95 53 31 61 35 0.37 0
PCT 11 BW6 0.98 54 31 77 35 0.26 0
PCT 18 BW5
-1.08 55 31 77 35 0.24 0
PCTO 17 BW5 0.99 56 31 105 35 1.01 0
PCT 28 BW5 0.98 57 31 59 37 0.43 0
PCT 13 BW6
-0.93 58 31 119 37 0.28 0
PCT 17 10H
-0.98 59 31 80 38 0.22 0
PCT 17 BW4
-0.41.
60 31 80 38 0.30 0
PCT 20 BW4 0.91 61 31 80 38 0.22 0
PCT 16 BW5
-0.82 62 31 80 38 0.60 0
PCT 28 BW6
-0.85 63 31 82 38 0.41
.0 PCT 23 BW5
-0.82 64 31 82 38 1.07 0
PCT 36 BW6
-0.70 65 31 21 39 0.21 0
PCT 7
BW5 0.85 66 31 51 39 0.20 0
PCT 6
BW6 0.85 67 31 113 39 0.61 0
PCT 21 BW7
'0.98 68 31 2
40 0.43 0
PCT 22 04C 0.88 69 31 42, 40
.0.28 0
PCT 9
BW5 0.80 70 31 50 40 0.32 0,
PCT 10 BW5
-0.88 71 31 37 41 0.22 0
PCT 7
BW5
-0.93 72 31 39 41 0.78 0
PCT 20 BW5
-0.99 73 31 39 41 0.25 0
PCT 8
BW5 0.86 74 31 102 42 0.64 0
PCT 21 BW3
-0.46 75 31 1
43 0.06 0
PCT 2
07H 0.48 76 31 59 43 0.22 0
, 7 BW5 0.91 77 31 105 45 0.33 0
PCT 14 BW7 0.90 78 31 123 45 0.39 0
PCT 15 02H 0.95 79 31 22 46 0.19 0
PCT 6
BW5
-0.90 80 31 128 46 0.26 0
PCT 11 02H
-0.09 81 31 45 49 0.04 0
PCT.
1 BW5
-0.48 82 31 45 49 0.36 0.:,,
PCT 11 BW5 0.65 83 31 59 49 0.38 0
PCT 12 BW5 0.79 84 31 99 51 0.27 0
PCT -
19 04H 0.27 85 31 131
'51 0.13 0
PCT 11 10H
-0.82 86
.31 131 51 0.32 0
PCT 19 10H 0.82 87 31 46 52 0.52 0
PCT 14 BW5 0.87 88 31 43 53 0.54 0
.14 BW5 0.71 89 31 105 53 0.54 0
PCT 27 BW3
-0.77 90 31 133 53 0.29 0
PCT 17
/
09C
-0.85 91 31 133 53 0.34 0
PCT 190 08C 0.89 92 31 22
.54 0.20 0
PCT 6
BW5
-0.88 93 31 82 54 0.69 0
PCT 30 BW5
-0.85 94 31 82 54 0.97 0
PCTS 34 BW5 0.82 95 31 82 54 0.26 0
PCT 18 BW6
-0.76 96 31 82 54 0.28
,0 PCT' 19 BW6 0.85 97 31 19 55 0.70 0'
POT 27 BW5 1.06
'98 31 24 56 0.21 0
- PCT, 10 BW5
-0.48 to W3F1-20107 0031 7 of 26 Table D-3 SG31 Service Induced Indications - Wear at Supports - RF16 Count SG Row Col Volts Deg Ind Per TW Locn Inch1 99 31 50 56 0.37 0
PCT 15 BW5
-0.80 100 31 50 56 0.57 0
PCT 20 BW5 0.92 101 31 23 57 0.32 0
PCT 18 BW5 0.94 102 31 51 57 0.23 0
PCT 15 BW4 0.92 103 31 125 57 0.42 0
POT 14 08C 0.52 104 31 135 57 0.37 0
PCT 20 10H 0.65 105 31 76 58 0.30 0
PCT 19 BW6
-0.77 106 31 129 59 0.39 0
PCT 20 BW3
-0.66 107 31 24 60 0.27 0
PCT 12 BW5
-0.77 108 31 30 60 0.48 0
PCT 18 BW5 0.90 109 31 32 60 0.27 0
PCT 12 BW5 0.89 110 31 138 60 0.45 0
PCT 17 09H
-0.91 111 31 81 61 0.55 0
PCT 27 BW4 0.81 112 31 82 62 0.34 0
PCT 21 BW4
-0.73 113 31 82 62 0.24 0
PCT 17 BW5 1.03 114 31 82 62 0.32 0
PCT 20 BW6
-0.70 115 31 138 62 0.32 0
PCT 13 01H 0.79 116 31 19 63 0.15 0
PCT 11 BW5
-1.19 117 31 19 63 0.39 0
PCT 20 BW5 0.70 118 31 35 63 0.38 0
PCT 20 BW5
-0.71 119 31 35 63 0.46 0
PCT 22 BW5 0.93 120 31 61 63 0.22
.0 PCT 14 BW5
-0.71 121 31 61 63 0.47 0
PCT 22 BW5 1.01 122 31 63 63 0.38 0
PCT 15 BW4
-0.80 123 31 63 63 0.22 0
PCT 10 BW4 0.86 124 31 63 63 0.35 0
PCT 15 BW5 0.80 125 31 63 63 0.45 0
PCT 17 BW6 0.70 126 31 133 63, 0.28 0
PCT 17 BW5 0.86 127 31 139 63 0.30 0
PCT 17 BW1
-1.62 128 31 23 65 0.31 0
PCT 18 BW5 0.97 129 31 135 65 0.32 0
PCT 18 BW8
-0.81 130 31 137 65 0.16 0
PCT 12 BW2
-0.53 131 31 137 65 0.34 0
PCT 19 BW4 0.97 132 31 44 66 0.59 0
PCT 20 BW5 0.89 133 31 46 66 0.37 0
PCT 15 BW9 1.74 134 31 50 66 1.64 0
PCT 37 BW5
-0.79 135 31 50 66 0.10 0
PCT 5
BW5
-0.03 136 31 50 66 0.22 0
PCT 10 BW5 0.92 137 31 51 67 0.12 0
PCT 9
BW4
-0.87 138 31 51 67 0.93 0
PCT 30 BW4 0.91 139 31 51 67 0.37 0
PCT 19 BW5
-0.63 140 31 121 67 0.25 0
PCT 17 03H 0.81 141 31 135 67 0.27 0
PCT 16 BW3
-0.70 142 31 40 68 0.27 0
PCT 12 BW5 0.87 143 31 46 70 0.59 0
PCT 20 BW5
-0.67 144 31 46 70 0.44 0
PCT 17 BW5
-0.06 145 31 46 70 0.85 0
PCT 26 BW5 0.89 146 31 50 70 0.33 0
PCT 13 BW5 0.89 147 31 138 70 0.29 0
PCT 17 08C 0.79 to W3F1-2010-0031 8 of 26 Table D-3 SG31 Service Induced Indications - Wear at Supports - RF16 Count SG Row Col Volts Deg Ind Per TW Locn Inch1 148 31 78 72 0.45 0
PCT 24 08C
-1.09 149 31 108 74 0.32 0
PCT 20 BW3
-0.90 150 31 103 75 0.21 0
PCT 15 02H 0.75 151 31 138 76 0.31 0
PCT 14 09C
-1.01 152 31 133 77 0.31 0
PCT 18 BW3
-0.51 153 31 133 77 0.34 0
PCT 19 BW4
-0.66 154 31 68 78 0.49 0
PCT 17 BW6 1.17 155 31 136 78 0.19 0
PCT 10 BW2
-1.20 156 31 61 79 0.29 0
PCT 17 BW5 0.85 157 31 78 80 0.33 0
PCT 13 BW5
-0.68 158 31 78 80 0.25 0
PCT 11 BW6 0.78 159 31 90 80 0.31 0
PCT 13 04H 0.91 160 31 96 80 0.19 0
PCT 9
03H 0.87 161 31 83 81 0.32 0
PCT 20 BW3 0.92 162 31 107 81 0.29 0
PCT 12 BW3 0.69 163 31 143 81 0.38 0
PCT 20 03H
-1.03 164 31 82 82 0.58 0
PCT 27 BW5 1.01 165 31 93 83 0.34 0
PCT 14 BW9 1.75 166 31 119 83 0.36 0
PCT 21 07C
-0.15 167 31 82 84 0.17 0
PCT 7
BW6
-0.71 168 31 82 84 0.19 0
PCT 9
BW6 0.93 169 31 83 87 0.27 0
PCT 12 BW7 0.94 170 31 70 88 0.29 0
PCT 12 BW9
-0.20 171 31 55 89 0.46 0
PCT 23 BW1
-1.80 172 31 121 91 0.28 0
PCT 18 02H
-0.84 173 31 144 92 0.24 0
PCT 11 04H 0.99 174 31 71 93 0.40 0
PCT 21 BW9
-1.67 175 31 133 93 0.24 0
PCT 10 BW1
-1.74 176 31 139 93 0.13 0
PCT 10 BW1
-1.85 177 31 139 93 0.05 0
PCT 4
BW9 1.99 178 31 56 94 0.62 0
PCT 27 BW9 4.01 179 31 69 95 0.31 0
PCT 19 BW9 1.93 180 31 82 96 0.56 0
PCT 27 BW5
-0.78 181 31 83 97 0.37 0
PCT 22 BW5
-0.78 182 31 83 97 0.22 0
PCT 16 BW5 0.52 183 31 83 97 0.33 0
PCT 20 BW6
-0.80 184 31 83 97 0.25 0
PCT 17 BW6 0.88 185 31 121 97 0.26 0
PCT 11 03H
-0.76 186 31 78 98 0.43 0
PCT 17 BW4
-0.66 187 31 78 98 0.08 0
PCT 4
BW4 0.89 188 31 78 98 0.57 0
PCT 20 BW6 1.19 189 31 78 98 0.26 0
PCT 12 08C 0.89 190 31 130 98 0.07 0
PCT 6
BW1
-1.71 191 31 134 98 0.23 0
PCT 15 01H 0.33 192 31 78 100 0.31 0
PCT 20 BW5
-0.75 193 31 78 100 0.17 0
PCT 14 BW5 0.08 194 31 78 100 0.33 0
PCT 20 BW5 0.83 195 31 78 100 0.26 0
PCT 17 BW6
-0.12 196 31 78 100 0.59 0
PCT 27 BW6
.0.83 to W3F1-2010-0031 9 of 26 Table D-3 SG31 Service Induced Indications - Wear at Supports - RF16 Count SG Row Col Volts Deg Ind Per TW Locn Inch1 197 31 98 100 0.26 0
PCT 10 04H 0.89 198 31 141 105 0.49 0
PCT 18 09H
-0.46 199 31 42 108 0.93 0
PCT 32 BW5
-0.71 200 31 42 108 0.12 0
PCT 10 BW5 0.19 201 31 42 108 0.60 0
PCT 26 BW5 0.93 202 31 78 108 0.46 0
PCT 24 BW4
-0.69 203 31 78 108 0.43 0
PCT 24 BW5
-0.69 204 31 78 108 0.24 0
PCT 17 BW6
-0.74 205 31 140 108 0.36 0
PCT 14 08H 0.83 206 31 39 111 0.13 0
PCT 6
BW5 0.33 207 31 39 111 0.65 0
PCT 21 BW5 0.95 208 31 131 111 0.34 0
PCT 14 09C 0.87 209 31 22 112 0.16 0
PCT 12 BW5 1.12 210 31 40 112 0.25 0
PCT 16 BW5
-0.84 211 31 40 112 0.22 0
PCT 15 BW5 0.94 212 31 141 113 0.40 0
PCT 15 BW9
-1.50 213 31 31 115 0.25 0
PCT 10 01H 0.98 214 31 45 115 0.32 0
PCT 13 BW5
-0.74 215 31 45 115 0.09 0
PCT 5
BW5 0.12 216 31 45 115 0.26 0
PCT 11 BW5 0.68 217 31 49 115 0.37 0
PCT 14 BW5
-0.91 218 31 49 115 0.20 0
PCT 9
BW5 0.78 219 31 45 117 0.39 0
PCT 15 BW5
-0.78 220 31 99 117 0.27 0
PCT 12 BW4
-0.71 221 31 135 119 1.22 0
PCT 35 BW2
-0.77 222 31 135 119 0.12 0
PCT 10 BW2 0.18 223 31 135 119 0.64 0
PCT 27T BW2 1.05 224 31 135 119 0.15 0
PCT 11 BW3
-0.86 225 31 135 119 0.77-0 PCT 29 BW3 0.90 226 31 135 119 0.78 0
PCT 29 BW4
-0.77 227 31 135 119 0.12 0
PCT 10 BW4 0.15 228 31 135 119 0.74 0
PCT 29 BW4 1.01 229 31 135 119 0.41 0
PCT 21 BW7
-0.74 230 31 135 119 0.09 0
PCT 8
BW7
-0.03 231 31 135 119 0.20 0
PCT 14 BW7 1.12 232 31 22 120 0.16 0
PCT 12 BW5
-0.76 233 31 22 120 0.09 0
PCT 8
BW5 0.66 234 31 134 120 0.63 0
PCT 27 01C 0.81 235 31 133 121 0.71 0
PCT 28 BW2
-0.74 236 31 133 121 0.20 0
PCT 14 BW2 0.09 237 31 133 121 1.29 0
PCT 36 BW2 0.99 238 31 133 121 0.38 0
PCT 21 BW3
-0.37 239 31 133 121 0.17 0
PCT 12 BW3 0.00 240 31 133 121 0.33 0
PCT 19 BW4
-0.67 241 31 132 124 0.24 0
PCT 10 08H 0.86 242 31 133 125 0.29 0
PCT 12 07C
-1.10 243 31 40 126 0.26 0
PCT 11 BW5
-0.79
.244 31 72 126 0.09 0
PCT 8
02H
-0.83 245 31 72 126 0.34 0
PCT 20 BW4
-0.51 to W3F1-2010-0031 10 of 26 Table D-3 SG31 Service Induced Indications - Wear at Supports - RF16 Count SG Row Col Volts Deg Ind Per TW Locn Inch1 246 31 72 126 0.78 0
PCT 31 BW4 1.13 247 31 72 126 0.27 0
PCT 18 BW5
-0.88 248 31 72 126 0.35 0
PCT 21 BW5 0.15 249 31 82 126 0.26 0
PCT 17 BW6 1.01 250 31 131 127 0.12 0
PCT 6
07H
-0.63 251 31 131 127 0.29 0
PCT 12 07H 0.91 252 31 76 128 0.50 0
PCT 24 BW4 0.95 253 31 76 128 0.44 0
PCT 23 BW5
-0.60 254 31 76 128 0.25 0
PCT 17 BW5 0.00 255 31 76 128 0.38 0
PCT 21 BW5 1.03 256 31 76 128 0.40 0
PCT 22 BW6
-0.70 257 31 76 128 0.88 0
PCT 32 BW6 1.03 258 31 81 129 0.14 0
PCT 7
01H 0.80 259 31 105 129 0.16 0
PCT 13 BW1 2.03 260 31 127 129 0.32 0
PCT 13 BW2
-0.91 261 31 128 130 0.21 0
PCT 9
01H 0.90 262 31
.81 131 0.15 0
PCT 12 03H
-0.68 263 31 74 132 0.15 0
PCT 12 02H 0.89 264 31 74 132 0.04 0
PCT 4
03H
-0.28 265 31 74 134 0.36 0
PCT 21 BW6 0.81 266 31 92 134 0.17 0
PCT 8
03C 0.18 267 31 123 135 0.23 0
PCT 10 09H 0.97 268 31 122 136 0.30 0
PCT 19 02C 0.82 269 31 63 137 0.26 0
PCT 11 BW4
-0.91 270 31 63 137 0.42 0
PCT 15 BW5
-0.79 271 31 119 137 0.21 0
PCT 15 BW5
-0.18 272 31 119 137 0.11 0
PCT 10 BW5 0.91 273 31 78 138 0.55 0
,20 BW4
-0.73 274 31 78 138 0.15 0
PCT 7
BW4 0.61 275 31 82 138 0.26 0
PCT 12 BW4
-0.75 276 31 82 138 0.28 0
PCT 12 BW4 0.93 277 31 82 138 0.43 0
PCT 17 BW5 0.82 278 31 82 138 0.85 0
PCT 25 BW6 0.91 279 31 1
139 0.27 0
PCT 16 04C 0.83 280 31 67 139 0.28 0
PCT 18 08C 0.89 281 31 76 140 0.21 0
PCT 15 BW4
-0.97 282 31 76 140 0.20 0
PCT 15 BW4 0.76 283 31 76 140 0.23 0
PCT 16 BW5 0.15 284 31 76 140 0.29 0
PCT 18 BW5 0.77 285 31 76 140 0.15 0
PCT 12
- BW6, 0.12 286 31 76 140 0.77 0
PCT 30 BW6 0.79 287 31 82 140 0.63 0
PCT 27 BW4 1.04 288 31 82 140 0.88 0
PCT 32 BW6
-0.73 289 31 82 140 0.33 0
PCT 20 BW6 0.73 290 31 84 140 0.25 0
PCT 17 02H
-0.18 291 31 84 140 0.15 0
PCT 12 02H 0.73 292 31 92
- 140, 0.13 0
PCT 11 02H 0.89 293 31 105 141 0.16 0
PCT 11
'09C
-0.33 294 31 78 142 0.36 0
POT'
.15 BW4
-0.67 to W3F1-2010-0031 11 of 26 Table D-3 SG31 Service Induced Indications - Wear at Supports - RF16 Count SG Row Col Volts Deg Ind Per TW Locn Inch1 295 31 78 142 0.28 0
PCT 12 BW4 0.90 296 31 78 142 0.33 0
PCT 14 BW5 0.09 297 31 78 142 0.39 0
PCT 16 BW6
-0.79 298 31 82 142 0.49 0
PCT 18 BW6
-0.76 299 31 113 143 0.36 0
PCT 14 BW9 1.61 300 31 48 144 1.10 0
PCT 27 BW5
-0.86 301 31 48 144 0.45 0
PCT 16 BW5 1.09 302 31 74 144 0.34 0
PCT 19 BW5 0.82 303 31 74 144 0.43 0
PCT 22 BW6 0.88 304 31 78 144 1.32 0
PCT 36 BW4
-0.82 305 31 78 144 0.29 0
PCT 17 BW4
-0.09 306 31 78 144 1.02 0
PCT 33 BW4 0.70' 307 31 78 144 0.39 0
PCT 21 BW5
-0.76 308 31 78 144 0.64 0
PCT 27 BW5
-0.06 309 31 78 144 0.28 0
PCT 17 BW5'"
0.70 310-31 78 144 0.32 0
PCT 18 BW6
-0.78 311 31 78 144 1.03 0
PCT 33 BW6 0.78 312 31 95 145 0.42 0
PCT 21 09C 0.64 313 31 81 147 0.36 0
PCT 20 BW6
ý0.79 314 31 103 147 0.34 0
PCT 18 BW3 0.89 315 31 76 148 0.29 0
PCT 17 BW4
-0.58 316 31 76 148 0.16 0
PCT 11 BW4 1.05 317 31 83 149 0.73 0
PCT 28 BW7 1.02 318 31 83 155 0.14 0
PCT 7
08C
-1.06 319 31 93 155 0.25 0
PCT 11 02C
-0.86 320 31 44 156 0.16 0
PCT 8
BW5 0.10 321 31 44 156 0.41 0
PCT 16 BW5 0.70 322 31 48 158 0.37 0
PCT 20 BW5
-0.29 323 31 82 158 0.89 0
PCT 32 01C 0.89 324 31 81 159
,0.19 0
PCT 9
BW9 1.96 325 31 12 160 0.26 0
PCT 11 03H 0.91 326 31 79 161 0.39 0
PCT 21 02C 0.73 327 31 18 164 0.25 0
PCT 10 02H 0.95 328 31 60 164 0.42 0
PCT 21 01C
-0.87 329 31 1
167 0.37 0
PCT 20 03C 0.79 330 31 19 167 0.23 0
PCT 15 BW5
-0.70 331 31 19 167 0.54 0
PCT 24 BW5 0.93 332 31 1
169 0.31 0
PCT 17 03C
-0.25 333 31 1
169 0.20 0
PCT 13 03C 0.99 334 31 42 170 0.45 0
PCT 16 01C 0.21 335 31 16 172 0.38 0
PCT 14 01C
-0.30 336 31 5
- 175 0.33 0 '
POCT 13 01C
-0.20
I I to W3F1-2010-0031 12 of 26 Table D-4 SG32 Service Induced Indications - Wear at Supports-RF1 6 Count Row Col Volts Deg Ind Per Locn Inch1 1
19 3
0.18 0
PCT 13 BW5
-0.87 2
19 3
0.99 0
PCT 32 BW5 0.93 3
46 6
0.40 0
PCT 19 BW5
-0.64 4
29 7
0.31 0
PCT 18 BW5
-0.88 5
2 8
0.32 0
PCT 16 BW9
-0.93 6
41 9
0.23 0
PCT 15 BW5
-0.26 7
44 10 0.26 0
PCT 17 BW5
-0.68 8
44 10 0.09 0
PCT 8
BW5
-0.16 9
44 10 0.63 0
PCT 27 BW5 1.04 10 65 11 0.26 0
PCT 14 01C 0.06 11 67 11 1.33 0
PCT 36 BW6
-0.79 12
- 67.
11 0.40 0
PCT 19 BW6 0.06 13 67 11 0.48 0
PCT 21 BW6 0.89 14 19 13 0.23 0
PCT 13 05H 0.13 15 23 15 0.19 0
PCT 14 BW5
-0.84 16 33 15 0.30 0
PCT 18 BW5
-0.92 17 44 16 1.18 0
PCT 33 BW5
-0.62 18 44 16 0.56 0
PCT 23 BW5 0.98 19 80 16 0.17 0
PCT 11 BW9 1.45 20 82 16 0.32 0
PCT 17 BW9
-1.29 21 35 17 0.16 0
PCT 10 BW5
-0.69 22 46 18 0.36 0
PCT 20 BW5
-0.77 23 46 18 0.34 0
PCT 20 BW5 0.96 24 46 18 0.38 0
PCT 21 07C 0.84 25 48 18 1.50 0
PCT 39 BW5
-0.92 26 48 18 0.20 0
PCT 14 BW5 0.00 27 48 18 0.95 0
PCT 33 BW5 0.90 28 62 18 0.36 0
PCT 20 01H 0.76 29 71 19 0.14 0
PCT 9
BW9 1.60 30 81 19 0.13 0
PCT 8
BW9 1.95 31 4
20 0.25 0
PCT 12 06C
-0.10 32 74 20 0.33 0
PCT 18 BW9
-1.98 33 80 20, 0.32 0'
PCT 17 BW9 1.37 34 90 20 0.31 0
PCT 17 05H 0.79 35 90 20 0.70 0
PCT 26 09H
-0.97 36 79 21 0.49 0
PCT 21 BW9 1.33 37 81 21 0.33 0
PCT 16 BW6
-0.80 38 81 21 0.17 0
PCT 10 BW9 1.30 39 93 21 0.18 0
PCT 12 04H 0.80 40 82 22 0.11 0
PCT 8
BW9
-1.41 41 82 22 0.26 0
PCT 15 BW9 1.40 42 79 23 0.31 0
PCT 16 BW9 1.55 43 76 24 0.29 0
PCT 17 BW4
-0.94 44 76 24 0.35 0
PCT 19 BW5
-0.79 45 76 24 0.37 0
PCT 20 BW6 0.75 46 76 24 0.26 0
PCT 16 BW9 1.80 47 19 25 0.60 0
PCT 24 BW5
-0.74 48 19 25 0.35 0
PCT 18 BW5 1.16 49 69 25 0.51 0
PCT 22 BW6 0.89 to W3F1-2010-0031 13 of 26 Table D-4 SG32 Service Induced Indications - Wear at Supports - RF16 Count Row Col Volts Deg Ind Per Locn Inch1 50 71 25 0.20 0
PCT 11 BW9 1.62 51 77 25 0.21 0
PCT 12 BW9 1.41 52 79 25 0.36 0
PCT 17 BW6 0.99 53 79 25 0.81
.0 PCT
.28 BW9 1.51 54 81 25 0.31 0
PCT 16 BW4
-0.85 55 81 25 0.29 0
PCT 15 BW9 1.39 56 101 25 0.13 0
PCT 9
BW1
-1.49 57 101 25 1.27 0
PCT 34 BW1 1.92 58 76 26 0.21 0
PCT 13 BW9 1.55 59 80 26 0.37 0
PCT 19 08C
-0.95 60 82 26 0.20 0
PCT 13 BW5
-0.84 61 82 26 0.19 0
PCT 12 BW5 0.83 62 82 26 0.32 0
PCT 17 BW6
-0.89 63 82 26 0.69 0
PCT 27 BW6 0.98 64 82 26 0.34 0
PCT 18 08C 0.86 65 1
27 0.44 0
PCT 22 06C 0.64 66 23 27 0.22 0
PCT 13 BW5
-0.72 67 79 27 0.60 0
- 26 BW9 1.68 68 81 27 0.23 0
PCT 15 BW4
-0.72 69 81 27 0.24 0
PCT 15 BW4 0.94 70 81 27 0.24 0
PCT 15 BW5 0.83 71 81 27 0.50 0
PCT 23 BW6 0.95 72 101 27 0.43 0
PCT 20 BW9 1.40 73 4
28 0.28 0
PCT 13 05C
-0.69 74 4
28 0.27 0
PCT 12 03C
-0.70 75 80 28 0.20 0
PCT 11 BW6
-0.86 76 80 28 0.42 0
PCT 19 BW6 0.98 77 82 28 0.21 0
PCT 12 BW4
-0.76 78 82 28 0.17 0
PCT 10 BW4 1.11 79 82 28 0.26 0
PCT 14 BW5
-0.73 80 82 28 1.10 0
PCT 31 BW6 1.13 81 1
29 0.28 0
PCT 17 04C
.0.85 82 1
29 0.57 0
PCT 25 03C 0.86 83 77 29 0.22 0
PCT 12 BW6
-0.68 84 77 29 0.64 0
PCT 24 BW6 0.90 85 48 30 0.26 0
PCT 15 BW5
-0.74 86 48 30 0.20 0
PCT 13 BW5 0.81 87 94 30 0.62 0
PCT 26 09C 0.03 88 94 30 0.26 0
" PCT 16 09C 0.92 89 104 30 0.17 291 VOL 19 07C 1.85 90 1
31 0.19 0
PCT 13 05C
-0.36 91 1
31 0.24 0
PCT 15 03C
-0.91 92 1
31 0.21 0
PCT 14 03C 0.85 93 3
31 0.71 0
PCT 28 05C 0.80 94 43 31 0.19 0
PCT 12 BW5
-0.80 95 107 31 0.27 0
PCT 15 BW1
-1.19 96 107 31 0.41 0
PCT 20 BW9 1.46 97 109 31 0.32 0
PCT 17 BW1
-1.49 98 109 31 0.10 0
PCT 8
BW1 1.68 to W3F1-2010-0031 14 of 26 Table D-4 SG32 Service Induced Indications - Wear at Supports - RF16 Count Row Col Volts Deg Ind Per Locn Inch1 99 4
32 0.19 0
PCT 10 05C
-0.86 100 46 32 0.48 0
PCT 20 BW5
-0.91 101 46 32 0.15 0
PCT 9
BW5 0.06 102 46 32 0.16 0
PCT 10 BW5 0.97 103 68 32 0.23 0
PCT 12 BW9
-1.62 104 76 32 0.11 0
PCT 7
BW9
-1.86 105 33 33 0.37 0
PCT 17 BW5
-0.86 106 67 33 0.28 0
PCT 14 BW9 1.42 107 79 33 0.17 0
PCT 10 BW9 1.38 108 81 33 0.52 0
PCT 21 BW5
-0.83 109 81 33 0.60 0
PCT 23 BW5 0.89 110 81 33 0.27 0
-14 BW9 1.60 111 83 33 0.24 0
PCT 13 BW5 0.89 112 59 35 0.16 0
PCT 11 BW6 0.00 113 59 35 0.93 0
PCT 31 BW6 0.80 114 69 35 0.31 0
PCT 18 BW5 0.85 115 77 35 0.25 0
PCT 16 BW5 0.80 116 83 35 0.17 0
PCT 12 BW3 0.96 117 83 35 0.68 0
PCT 28 BW5 0.98 118 83 35 0.46 0
PCT 23 BW7
-0.92 119 83 35 0.50 0
PCT 24 BW7 1.05 120 111 35 0.43 0
PCT 20 09H
-1.08 121 100 36 0.20 0
PCT 11 BW5
-0.78 122 108 36 0.56 0
PCT 23 BW1 2.04 123 43 37 0.55 0
PCT 22 BW5
-0.65 124 43 37 0.41 0
PCT 18 BW5 1.01 125 77 37 0.21, 0
PCT 12 BW4
-0.85 126 77 37 0.36 0
PCT 17 BW4 0.94 127 77 37 0.24 0
PCT 13 BW5
-0.94 128 77 37 0.49 0
- 20.
BW5 0.92 129 111 37 0.41 0
PCT 20 BW1 2.01 130 117
.37 0.26 0
PCT 14 05H
-0.89 131 41, 39 0.37 0
PCT 19 BW5 0.84 132 115 39 0.17) 0 PCT 11 BW9 1.48 133 117 39 0.32 0
PCT 17 BW5
-0.90 134 44 40 0.51 0
PCT 21 BW5
-0.65 135 44 40 0.08 0
PCT 5
BW5 0.16 136 44 40 0.27 0
PCT 14 BW5 1.01 137 46 40 0.25 0
PCT 13 BW5 0.98 138 94 40 0.83 0
PCT 27 BW3
-0.88 139 94 40 0.21 0
PCT 12 BW4
-0.98 140 94 40 0.22 0
PCT 12 BW5
-0.81 141 94 40 0.25 0
PCT 13 BW5 1.05 142 94 40 0.21 0
PCT 12 BW6
-0.71 143 94 40 0.80 0
PCT 26 BW6 0.94 144 81 41 1.27 0
PCT 33 BW5
-0.82 145 81 41 1.27 0
PCT 33 BW5 0.95 146 81 41 0.72 0
PCT 25 BW6
-0.86 147 81 41 0.15 0
PCT 9
BW6 0.86 to W3F1-2010-0031 15 of 26 Table D-4 SG32 Service Induced Indications - Wear at Supports - RF16 Count Row Col Volts Deg Ind Per Locn Inch1 148 83 41 0.30 0
PCT 15 BW3 0.98 149 2
42 0.37 0
PCT 17 05C
-0.90 150 82 42 0.36 0
PCT 20 08C 0.93 151 96 42 0.44 0
PCT 20 BW3
-0.75 152 96 42 0.22 0
PCT 13 BW3 0.81 153 96 42 0.67 0
PCT 26 BW5
-0.93 154 114 42 0.40 0
PCT 19 08C 0.74 155 113 43 0.19 0
PCT 12 BW9 0.94 156 119 43 0.14 0
PCT 10 08C
-0.19 157 119 43 0.27 0
PCT 15 08C 0.81 158 125 43 0.59 0
PCT 24 03C 0.83 159 2
44 0.29 0
PCT 17 03H 0.77 160 22 44 0.19 0
PCT 14 BW5
-0.86 161 124 44 0.19, 0
,11 BW6 0.89 162 1
45 0.37 0
PCT 20 04C
-0.28 163 1
.45 0.21 0
PCT 14 04C 0.74 164 67 45 0.47 0
. PCT 21 BW5 0.96 165 109
- 45.
0.36 0
PCT 20 BW6
-0.40 166 127 45 0.52 0
PCT 22 02C 0.77 167 48 46 0.27 0
PCT 15 BW5
-0.85 168 48 46 0.14 0
PCT 9
BW5 0.94 169 80 46 0.79 0
PCT 26 08C
-0.95 170 1
47 0.24 0
PCT 15 05C
-0.96 171 1
47 1.55 0
PCT 38 05C 0.83 172 43 47 0.18 0
PCT 11 BW5
-0.62 173 77 47 0.24 0
PCT 15 BW4
-0.87 174 44 48 0.41 0
PCT 19 BW5 0.79 175 80 48 1.09
- 0.
PCT 33 BW5
-0.71 176 126 48 0.28 0
PCT 16 09C
-0.86 177 3
49 0.34 0
PCT 19 05C
-0.99 178 77 49 0.28 0
PCT 14 BW5 0.96 179 79 49 0.27 0
PCT 13 BW6
-0.50 180 81 49 0.74 0
PCT 25 BW5 0.99 181 81 49 0.50 0
PCT 20 BW6
-0.56 182 81 49 0.08 0
PCT 5
BW6 0.09 183 81
.49 0.24 0
PCT 12 BW6 0.90 184 81 49 0.60 0
PCT 22 08C 0.74 185 81 49 0.27 0
PCT 13 07C
-0.90 186 44 50 0.38 0
PCT 20-BW5
-0.78 187 56 50 0.24 0
PCT 15 05C 0.77 188 1
51 0.40 0
PCT 21 04C 0.88 189 47 51 0.33 0
PCT 17 BW5 0.95 190 77 51 0.75 0
PCT 28 BW4
-0.68 191 77 51 0.92 0
PCT 31 BW6
-0.83 192 77 51 0.25 0
PCT 15 BW6
-0.31 193 77 51 0.22 0
PCT 13 BW6 0.74 194 83 51 0.24 0
PCT 15 BW7 1.01 195 44 52 0.52 0
PCT 21 BW5
-0.75 196 44 52 0.34 0
PCT 16 BW5 0.91 to W3F1-2010-0031 16 of 26 Table D-4 SG32 Service Induced Indications - Wear at Supports - RF16 Count Row Col Volts Deg Ind Per Locn Inch1 197 46 52 0.50 0
PCT 21 BW5
-0.81 198 48 52 0.23 0
PCT 12 BW5
-0.80 199 134 52 0.26 0
PCT 16 BW1 1.53 200 134 52 0.29 0
PCT 17 BW2 0.92 201 134 52 0.37 0
PCT 19 BW9 1.46 202 134 52 0.25 0
PCT 15 08C
-0.98 203 1
53 0.28 0
PCT 17 04C
-0.80 204 35 53 0.20 0
PCT 13 BW5
-0.95 205 35 53 0.24 0
PCT 15 BW5 0.95 206 69 53 0.13
.0 PCT 9
BW9 1.10 207 73 53 0.37 0
PCT 19 BW5
-0.74 208 73 53 0.62 0
PCT 25 BW5 1.09 209 73 53 1.14 0
PCT 34 BW6
-0.72 210 73 53 0.75 0
PCT 28 BW6 0.03 211 73 53 0.62 0
PCT 25 BW6 0.84 212 36 54 0.26 0
PCT 16 BW5
-0.85 213 82 54 0.69 0
PCT 24 BW4 0.90 214 114 54 0.51 0
PCT 24 BW7 1.10 215 81 55 0.31 0
PCT 14 BW5 0.91 216 107 55 0.65 0
PCT 22 BW5 0.09 217 107 55 0.53 0
PCT 20 BW5 0.80 218 107 55 0.49 0
PCT 19 BW6
-0.93 219 129 55 0.39 0
PCT 19 09C
-0.84 220 24 56 0.20 0
PCT 12 BW5
-0.80 221 94 56 0.20 0
PCT 10 BW3
-0.79 222 94 56 0.33 0
PCT 14 BW4
-0.79 223 94 56 0.35 0
PCT 15 BW5 0.92 224 51 57 0.23 0
PCT 15 BW6 0.96 225 73 57 0.19 0
PCT 14 BW5
-0.55 226 73 57 0.18 0
PCT 13 BW5 1.06 227 73 57 0.08 0
PCT 7
BW6 0.00 228 73 57 0.82 0
PCT 31 BW6 0.62 229 73 57 0.08 0
PCT' 7
BW6 0.82 230 77 57 0.37 0
PCT 21 BW5
-0.79 231 77 57 0.24 0
PCT 16 BW6
-0.86 232 81 57 0.90 0
PCT 32 BW4
-0.89 233 81 57 0.28 0
PCT 17 BW4
-0.12 234 81 57 0.30 0
PCT 18 BW4 0.73 235 81 57 0.34 0
PCT 20 BW5
-1.10
.236 81 57 0.23 0
P\\CT 15 BW5 0.63 237 81 57 0.13 0
PCT 10 BW6
-0.74 238 81 57 0.30 0
PCT 18 BW6 0.68 239 81 57 0.30 0
PCT 18 BW6 0.92 240 83 57 0.61 0
PCT 27 BW3
-0.71 241 83 57 0.31 0
PCT 19 BW5
-0.92 242 83 57 0.10 0
PCT 9
BW5 0.66 243 43 59 0.28 0
PCT 16 BW5
-0.87 244 43 59 0.56 0
PCT 24 BW5 1.00 245 83 59 0.31 0
PCT 14 BW7
-0.94 to W3F1-2010-0031 17 of 26 Table D-4 SG32 Service Induced Indications - Wear at Supports - RF16 Count Row Col Volts Deg Ind Per Locn Inch1 246 41 61 0.24 0
PCT 15 BW5 0.94 247 77 61 0.86 0
PCT 31 BW4
-0.87 248 77 61 0.70 0
PCT 29 BW4 1.03 249 133 61 0.47 0
PCT 21 BW3 0.94 250 133 61 0.54 0
PCT 23 BW5 0.77 251 137 61 0.27 0
PCT 15 09C
-1.11 252 41 63 0.24 0
PCT 15 BW9 1.72 253 43 63 1.34 0
PCT 36 BW5 0.76 254 137 63 0.25 0
PCT 14 09C
-1.05 255 46 64 0.48 0
PCT 21 BW5
-0.84 256 46 64 0.23 0
PCT 13 BW5
-0.16 257 46 64 1.69 0
PCT 40 BW5 0.96 258 82 64 0.41 0
PCT 21 BW4
ý-0.52 259 82 64 1.03 0
PCT 33 BW4 0.31 260 82 64 1.53 0
PCT 39 BW4 1.01 261 82 64 0.75 0
PCT 29 BW6
-0.79 262 82 64 0.35 0
PCT 19 BW6 0.03 263 82 64 0.30 0
PCT 18 BW6 0.79 264 92 64 0.46 0
PCT 21 BW5 0.93 265 118 64 0.23 0
PCT 14 04H 0.92 266 37 65 0.24 0
PCT 15 BW5
-0.88 267 37 65 0.13 0
PCT 10 BW5 0.00 268 119 67 0.40 0
PCT 19 09C 0.16 269 141 69 0.48 0
PCT 21 BW5
-0.80 270 141 69 0.32 0
PCT 16 BW5 0.96 271 141 69 0.38 0
PCT 18 BW7 0.72 272 77 71 0.34 0
PCT 15 BW4 0.93 273 77 71 0.39 0
PCT 17 BW5 0.79 274 77 71 0.32 0
PCT 15 BW6 0.91 275 139 71 0.47 0
PCT 21 BW2
-0.80 276 92 72 0.32 0
PCT 17 BW5
-0.81 277 102 72 0.09 0
PCT 7
BW9 1.78 278 130 72 0.15 0
PCT 11 04H 0.89 279 141 73 0.21 0
PCT 12 05H
-0.19 280 141 73 0.16 0
PCT 10 BW1
-1.58 281 141 75 0.35 0
PCT 18 BW1 1.64 282 67 77 0.24 0
PCT 14 BW9
-1.40 283 143 77 0.29 0
PCT 15 BW2
-0.91 284 110 78 0.38 0
PCT 18 BW6
-0.94 285 112 80 0.22 0
PCT 13 BW3
-0.87 286 112 80 0.10 0
PCT 7
BW3 0.94 287 105 83 0.27 0
PCT 15 08C 0.84 288 143 83 0.15 0
PCT 9
BW8 0.89 289 128 86 0.19 0
PCT 11 09C 0.93 290 71 87 0.25 0
PCT 13 BW9 0.50 291 143 87 0.17 0
PCT 12 09H 0.98 292 105 89 0.44 0
PCT 21 BW5 0.91 293 117 89 0.25 0
PCT 15 BW4
-0.80 294 143 89 0.22 0
PCT 14 09H 0.83 to W3F1-2010-0031 18 of 26.
Table D-4 SG32 Service Induced Indications - Wear at Supports - R1 6 Count Row Col Volts Deg Ind Per Locn Inch1 295 145 89 0.31 0
PCT 18 BW4
-0.96 296 145 89 0.47 0
PCT 22 BW7
-0.84 297 145 89 0.82 0
PCT 29 BW8
-0.86 298 145 89 0.63 0
PCT 26 BW8 0.83 299 145 89 0.32 0
PCT 18 08C
-1.08 300 145 89 0.41 0
PCT 21 08C 0.70 301 67 91 0.06 0
PCT 4
BW9 3.50 302 81 91 0.31 0
PCT 18 BW4 0.92 303 81 91 0.23 0
PCT 15 BW5 0.90 304 81 91 0.35 0
- 19.
BW6
-0.68 305 111 91 0.33 0
PCT 16 08C 0.68 306 119 91 0.57 0
PCT 22 08C
-0.99 307 66 92 0.03 0
PCT 3
BW9
-1.37 308 66 92 0.05 0
PCT 4
BW9 0.35 309 144 92 0.21 0
PCT 12 08C 0.80 310 65 93 0.08
(
0 PCT 5
BW9 3.64 311 69 93 0.08 0
PCT 6
BW9 0.12 312 81 93 0.28 0
PCT 16 BW4
-0.80 313 81 93 0.28 0
PCT 16 BW4 0.77 314 64 94 0.16 0
PCT 9
BW9 3.25 315 68 94 0.19 0
PCT 13 BW9 3.92 316 76 94 0.37 0
PCT 20 08C
-0.80 317 98 94 0.21 0
PCT 13 BW9 2.05 318 79 95 0.25 0
PCT 15 BW4
-0.90 319 79 95 0.25 0
PCT 15 BW4 0.71 320 145 95 0.69 0
PCT 27 BW8
-0.51 321 145 95 0.26 0
PCT 15 BW8 0.88 322 64
.96 0.16 0
PCT 9
BW9 3.30 323 66 96 0.47 0
PCT 20 BW1 1.79 324 68 96 0.13 0
PCT 9
BW9 0.48 325 67 97 0.32 0
PCT 18 02H
-0.79 326 67 97 0.08 0
PCT 6
BW9 3.37 327 81 97 0.55 0
PCT 24 BW4 0.96 328 81 97 0.17 0
PCT 12 BW5
-0.80 329 81 97 0.75 0
PCT 28 BW5 0.81 330 81 97 0.27 0
PCT 16 BW6
-0.71 331 81 97 0.16 0
PCT 11 BW9 0.25 332 68 98 0.05 0
PCT 4
BW9 0.25 333 72 98 0.31 0
PCT 18 BW9 0.16 334 79 99 0.49 0
PCT 23 BW4
-0.70 335 79 99 0.20 0
PCT 14 BW5
-0.22 336 79
'99 0.14 0
PCT 10 BW5 0.95 337 68 100 0.05 0
PCT 4
BW9 1.97 338 144 100 0.22 0
PCT 12 BW9
-1.77 339 68 102 0.32 0
PCT 15 BW9 1.90 340 143 103 0.42 0
PCT 21 BW9
-1.92 341 114 106 0.34 0
PCT 17 BW4
-0.19 342 77 107 0.29 0
PCT 15 BW4
-0.84 343 77 107 0.51 0
PCT 21 BW5
-0.74
"f to W3F1-2010-0031 19 of 26 Table D-4.
SG32 Service Induced Indications - Wear at Supports - RF16 Count Row Col Volts Deg Ind Per Locn Inch1 344 77
.107 1.26 0
PCT 33 BW5 0.16 345 77 107 1.43 0
PCT 35 BW5 0.86 346 77 107 0.46 0
PCT 20 BW6
-0.86 347 77 107 0.64 0
PCT 24 BW6
-0.10 348 83 107 0.37 0
PCT 17 BW3
-1.00 349 119 107 0.37 0
PCT 19 08C
-1.08 350 92 108 0.27 0
PCT 16 06C
-0.77 351 77 109 0.60 0
PCT 26 BW6 0.86 352 113 109 0.70 0
PCT 27 BW3 0.80 353 115 109 0.30 0
PCT 17 BW8 0.96 354 50 110 1.66 0
PCT 37 BW5
-0.79 355 50 110 0.23 0
PCT 12 BW5 0.82 356 82 110 0.23 0
PCT 13 BW5
-0.86 357 82 110 0.24 0
PCT 13 BW6 0.73 358 37 111 0.34 0
PCT 18 BW5 0.81 359 41 111 1.32 0
PCT 34 BW5 0.84 360 99 111 0.32 0
PCT 18 BW3 0.94 361 32 112 0.10 0
PCT 8
BW5
-0.76 362 32 112
.0.37 0
PCT 19 BW5 0.83 363 36 112 0.20 0
PCT 13 BW5
-0.82 364 38 112 0.34 0
PCT 17 05C
-0.76 365 76 112 0.19 0
PCT 13 03H
-0.77 366 82 112 0.19 0
PCT 13 BW6 0.78 367 100
.112 0.31 0
PCT 16 08C 0.47 368 114 112 0.33 0
PCT 16 BW3 0.97 369 81 113 0.73 0
PCT 28 BW4 0.80 370 135 113 0.61 0
PCT 25 BW8
-0.06 371 30 114 0.20 0
PCT 12 03C
-0.89 372 98 114 0.32 0
PCT 19 08C 0.86 373 25 115 0.15 0
PCT 10 BW5
-0.98 374 123 115 0.28 0
PCT 17 08C
-0.99 375 123 115 0.16 0
PCT 12 08C 0.80 376 127 115 0.30 0
PCT 17 08C
-0.37.
377 40 116 0.42 0
PCT 20 BW5 1.04 378 46 116 0.68 0
PCT 26 BW5 0.89 379 106 116 0.30 0
PCT 16 BW7
-0.91 380 19 117 0.64 0
PCT 26 BW5
-1.07
---381 29 117 0.34 0
PCT 17 06C 0.80 382 77 117 1.17 0
PCT 35 BW6
-0.76 383 77 117 0.68 0
PCT 27 BW6 0.86 384 133 117 0.46 0
PCT 22 BW3 0.92 385 135 117 0.34, 0
PCT 19 01C 0.71 386 74 118 0.82 0
PCT 27 BW4
-0.77 387 74 118 1.10 0
PCT 31 BW5
-0.77 388 74 118 0.28 0
PCT 15 BW6
-0.61 389 74 118 0.39 0
PCT 18 BW6 0.83 390 2
122 0.24 0
PCT 13 01C 0.85 391 40 122 0.15 0
PCT 11 BW5
-0.74 392 40 122 0.22 0
PCT 15 BW5 0.81
I I I
I to W3F1-2010-0031 20 of 26 Table D-4 SG32 Service Induced Indications - Wear at Supports - RF16 Count Row Col Volts Deg Ind Per Locn Inch1 393 104 122 0.35 0
PCT 20 BW3
-0.87 394 113 123 0.38 0
PCT 21 BW3 0.91 395 37 125 0.30 0
PCT 13 BW5
-1.09 396 81 125
'0.23 0
PCT 15 BW4 0.75 397 127 125 0.24 0
PCT 15 06C
-0.83 398 133 125 0.50 0
PCT 23 04C 1.08 399 133 125 0.28 0
PCT 17 02C 1.08 400 2
126 0.36 0
PCT 17 05C
-0.88 401 41 127 0.40 0
PCT 21 BW5 0.82 402 131 127 0.21 0
PCT 14 BW1 2.03 403 22 128 0.25 0
PCT 11 02H 0.72 404 82 128 0.21 0
PCT 14 BW5
-0.76 405 82 128 0.78 0
PCT 29 BW5 0.94 406 82 128 0.48 0
PCT 23 BW6 0.85 407 43
- 129, 0.26 0
PCT 12 BW5
-0.68 408 43 129 0.26 0
PCT 12 BW5
.0.58 409 81 129 0.26 0
PCT 16 08H
-0.74 410 83 131 0.32 0
PCT 16 BW7 1.01 411 125 131 0.33 0
PCT 19 02C 0.83 412 126 132 0.22 0
PCT 14 10H
-1.04 413 126 132 0.30 0
PCT 18 02C
-0.80.
414 111 133 0.23 0
PCT 13 BW3 0.85 415 123 133 0.28 0
PCT 15 03C 0.83 416 125 133 0.26 0
PCT 14 BW4
-0.80 417 100 134 0.23 0
PCT 15 07C
-0.03 418 1
135 0.29 0
PCT 16 04C 0.88 419 82 136 0.24 0
PCT 13 BW4
-0.59 420 92 136 0.33 0
PCT 16 BW4
-0.82 421 92 136 0.36 0
PCT 17 07C 0.78 422 109 137 0.52 0
PCT 22 08C 0.82 423
- 41.
139 0.47 0
PCT 19*
BW5 0.86 424 79 139 0.39 0
PCT 18 08C
-0.25 425 79 139 0.16 0
PCT 10 08C 0.78 426 80 140 0.47 0
PCT 20 BW9 1.98 427 84 140 0.27 0
PCT 14 BW9
-1.86 428 23 141 0.26 0
PCT 12 03H 0.86 429 37 141 0.34 0
PCT 15 BW5
-0.87 430 81 141 0.29 0
PCT 17 08C
-0.28 431 109 141 0.31 0
PCT 16 BW5 0.91 432 50 142 0.42 0
PCT 17 BW5
-0.77 433 66 142 0.34 0
PCT 16 08C 0.85 434 106 142 0.23 0
PCT 15 09H 0.77 435 75
.143 0.20 0
PCT 11 04C
-0.15 436 105 143 0.58 0
PCT 23, 09H
-0.79 437 105 143 0.25 0
PCT 14 09H 0.13 438 105 143 0.44 0
PCT 20 BW3 1.03 439 105 143 0.33 0
PCT 17 BW6
-0.79 440 82 144 0.56 0
PCT 22 BW5 0.61 441 96 144 0.38 0
PCT 19 08C
-1.08
I I
. to W3F11-2010-0031 21 of 26 Table D-4 SG32 Service Induced Indications-Wear at Supports - RF16 Count Row Col Volts Deg Ind Per Locn Inch!1 442 104
.144 0.24 0
PCT 15 04H 0.65 443 45 145 1.03 0
PCT 30 BW5
-0.83 444 45 145 0.63 0
PCT 23 BW5 0.86 445 81 145 0.29 0
PCT 17 08H
-0.80 446 109 145 0.27 0
PCT 15 09H 0.79 447
- 84.
146 0.20 0
PCT 13 BW9
-1.56 448 47 147 0.38.
0 PCT 21 BW5
-0.79 449 47 147 0.64 0
PCT 27 BW5 0.89 450 91 147 0.32 0
PCT 16 09C
-0.98 451 103 147 0.35 0
PCT 17 090
-1.10 452 82 148 0.34 0
PCT 16 BW4
-0.65 453 41 149 1.70 0
PCT 38 BW5 0.87 454 43
ý149 0.48 0
PCT 19 BW5 0.86 455 49 149 0.14 0
PCT 8
BW5
-0.10
- 456, 49 149 0.89 0
PCT 28 BW5 0.89 457 101.'
149 0.53 0
PCT 22 09C
-0.92 458 101 149 0.60 0
PCT 24 09C 0.70 459 103 149 0.35 0
POCT 17 02H 0.86 460 103 149 0.95 0
PCT 30 09H
-0.18 461 103 149 0.25
.0 PCT
.14 09H 0.92 462 80 150 0.26 0
PCT 15 08H 0.96 463 41 151 0.29 0
PCT 18 BW5 0.00 464 43 151 0.41 0
PCT 21 BW5 0.80 465 84 152 0.15 0
PCT 10 BW9
-1.85 466 96
.152 0.26 0
PCT 15 09H
-0.94 467 96 152 0.16 0
PCT 11 09H 0.03 468 40 154 0.63 0
PCT 23 BW5 0.86 469 37 155 0.53 0
PCT 25 BW5
-0.84 470 66 156 0.33 0
PCT 17 08C
-0.31 471 37 157 0.45 0
PCT 18 BW5
-0.87 472 37
-157 0.27 0
PCT 13 BW5 0.93 473 85
.157 0.31 0
PCT 17 09C
-1.09 474 38 158 0.33
.0 PCT 15 BW5 0.89 475 86 158 0.49 0
PCT' 23 BW9 1.60 476 86 158 0.13 0
PCT 10 09C
-0.09 477 86 158 0.26 0
PCT 16 09C 0.85 478 79 159 0.43 0
PCT 21 BW9 1.76 479 83 159 1.35 0
PCT 36 BW9 1.77 480 24 160 0.32.
0 PCT 14 03H 0.76 481 70 160 0.21 0
PCT 13 08C
-0.99 482 70
.160 0.51 0
PCT 22 08C 0.82 483 78 160 0.62 0
PCT 25 BW9 1.38 484 80 160 0.91 0
PCT 30 BW9 1.80 485 1-161 0.08 0
PCT 5
07C 0.03 486 76 162 0.22 0
PCT 14 BW1
-1.75 487 76 162 0.46 0
PCT 22 BW9 1.60 488 14 164 0.40 0
PCT 20 040
-0.36 489 41
.. 167 0.41 0
PCT 20,
. BW5 0.81 490 45 167 0.65 0
PCT 26 BW5
-0.70
I I to W3F1-2010-0031 22 of 26 Table D-4 SG32 Service Induced Indications - Wear at Supports - RF1 6 Count Row Col Volts Deg Ind Per Locn Inch1 491 53 169 0.36 0
PCT 19 01C 0.12 492 34 170 0.41 0
PCT 19 BW5 0.89 493 18 174 0.36 0
PCT 19 02C
-0.85 494 20 174 0.22 0
PCT 14 BW5
-0.77 495 1
175 0.36 0
PCT 19 01H 0.00 496 3
175 0.20 0
PCT 13 01H
-0.87 497 11 175 0.84 0
PCT 29 BW1 1.75
I
, to W3F1-2010-0031 23 of 26 Table D-5 SG31 SG32 Service Induced Indications - Historical Volumetrics Count SG Row Col Volts Deg Ind Per Locn Inch1 Inch2 Length Width Ceg 1
31 2
156 0.28 131 VOL
,29 TSC 0.55 0.78 0.22 34 2
32 104 30 0.17 291 VOL 19 07C 1.85 0.33 0.19 29
w 4
I ( to W3F1-2010-0031 24 of 26 Table E-2 SG31 Plugging List - RF16 Count SG Row Col Reason 1
31 7
13 Egg-Crate SAI 2
31 28 18 Egg-Crate SAI 3
31 9
19 Egg-Crate SAI 4
31 13 23 Egg-Crate SAI 5
31 11 29 Egg-Crate SAI 6
31 83 31 Egg-Crate SAI 7
31 93 31 Egg-Crate SAI 8
31 90 36 Egg-Crate SAI 9
31 60 38 Batwing SAI 10 31 62 40 Egg-Crate SAI 11 31 17 41 Egg-Crate SAI 12 31 59 41 Egg-Crate SAI 13 31 10 42 Egg-Crate SAI 14 31 5
43 Egg-Crate SAI 15 31 66 44 Egg-Crate SAI 16 31 5
47 Egg-Crate SAI 17 31 6
50 Egg-Crate SAI 18 31 88 50 Egg-Crate SAI 19 31 3
51 Egg-Crate SAI 20 31 88 52 Egg-Crate SAI 21 31 104 52 Egg-Crate SAI 22 31 5
55 Egg-Crate SAI 23 31 79 55 Egg-Cýate SAI 24 31 36 56 Egg-Crate SAI 25 31 9
- 57.
Egg-Crate SAI 26 31 19 57 Egg-Crate SAI 27 31 42 58 Egg-Crate SAI 28 31 72 58 Egg-Crate SAI 29 31 88 58 Egg-Crate SAI 30 31 39 59 Egg-Crate SAI 31 31 75 59 Egg-Crate SAI 32 31 99 59 Egg-Crate SAI 33 31 32 60 Egg-Crate SAI 34 31 35 61 Egg-Crate SAI 35 31 17 63 Egg-Crate SAI 36 31 70 64 Egg-Crate SAI 37 31 53 67 Egg-Crate SAI 38 31 92 68 Egg-Crate SAI 39 31 69 71 Egg-Crate SAI 40 31 52 74 Egg-Crate SAl 41 31 90 74 Egg-Crate SAI 42 31 78 78 Egg-Crate SAI 43 31 73 79 Egg-Crate SAI 44 31 85 83 Egg-Crate SAI 45 31 94 88 Tubesheet SAI 46 31 57 93 Egg-Crate SAI 47 31 89 93 Tubesheet SAI 48 31 65 97 Egg-Crate SAI 49 31 118 98 Egg-Crate SAI 2
a t
4 to W3F1-2010-0031 25 of 26 Table E-2 SG31 Plugging List - RF16 Count SG Row Col Reason 50 31 67 99 Egg-Crate SAI 51 31 99 99 Egg-Crate SAI 52 31 84 102 Egg-Crate SAI 53 31 95 103 Egg-Crate SAI 54 31 64 106 Egg-Crate SAI 55 31 98 106 Batwing SAI 56 31 68 108 Egg-Crate SAI 57 31 18 112 Egg-Crate SAI 58 31 51 113 Tubesheet SCI 59 31 27 115 Egg-Crate SAI 60 31 109 115 Egg-Crate SAI 61 31 6
116 Egg-Crate SAI 62 31 120 116 Egg-Crate SAI 63 31 55 117 Egg-Crate SAI 64 31 8
118 Egg-Crate SAI 65 31 80 118 Egg-Crate SAI 66 31 33 119 Egg-Crate SAI 67 31 6
122 Egg-Crate SAI 68 31 18 122 Egg-Crate SAI 69 31 66 122 Egg-Crate SAI 70 31 41 123 Egg-Crate SAI 71
- 31.
46 126 Egg-Crate SAI 72 31 53 127 Egg-Crate SAI 73 31 73 129 Egg-Crate SAI 74 31 16 130 Egg-Crate SAI 75 31 69 131 Egg-Crate SAI 76 31 81 131 Egg-Crate SAI 77 31 14 134 1Egg-Crate SAI 78 31 54 134 Egg-Crate SAI 79 31 31 135 Egg-Crate SAI 80
.31 85 137 Egg-Crate SAI 81 31 119 137 Batwing SAI 82 31 4
140 Egg-Crate SAI 83 31 6
142 Egg-Crate SAI 84 31 36 144 Egg-Crate SAI 85 31 7
145 Egg-Crate SAI 86 31 106 148 Administrative - CUD 87 31 24 156 Egg-Crate SAI 88 31 26 158 Egg-Crate SAI
'? t j to W3F1-2010-0031 26 of 26 Table E-3 SG32 Plugging List - RF16 Count SG Row Col Reason 1
32 17 25 Eggcrate SAI 2
32 67 33 Eggcrate SAI 3
32 46 36 Eggcrate SAI 4
32 29 37 Batwing SAI 5
32 9
39 Eggcrate SAI 6
32 89 41 Eggcrate SAI 7
32 34 42 Batwing SAI 8
32 74 44 Eggcrate SAI 9
32 53 47 Eggcrate SAI 10 32 31 55 Eggcrate SAI 11 32 46 64 Support wear 12 32 93 67 Eggcrate SAI 13 32 112 68 Eggcrate SAI 14 32 85 87 Eggcrate SAI 15 32 91 87 Eggcrate SAI 16 32 85 97 Eggcrate SAI 17 32 83 103 Eggcrate SAI 18 32 68 104 Eggcrate SAI 19 32 70 104 Eggcrate SAI 20 32 79 105 Eggcrate SAI 21 32 85 109 Eggcrate SAI 22 32 30 114 Eggcrate SAI 23 32 13 115 Eggcrate SAI 24 32 89 117 Eggcrate SAI 25 32 77 119 Batwing SAI 26 32 38 120 Tubesheet SCI 27 32 91 123 Eggcrate SAI 28 32 61 127 Eggcrate SAI 29 32 73 127 Eggcrate SAI 30 32 75 127 Eggcrate SAI 31 32 46 128 Eggcrate SAI 32 32 14 132 Eggcrate SAI 33 32 30 132 Eggcrate SAI 34 32 42 132 Eggcrate SAI 35 32 13 133 Eggcrate SAI 36 32 29 135 Eggcrate SAI 37 32 39 139 Eggcrate SAI 38 32 30 144 Eggcrate SAI 39 32
.82 144 Eggcrate SAI 40 32 31 149 Eggcrate SAI
/'*