E-mail from S. Collins of USNRC to Various, OCA Followup Questions: Action for 11/21 Three Mile Island - Containment Contamination Event
ML101230439
Person / Time
Site: Crane  Constellation icon.png
Issue date: 11/23/2009
From: Collins S
NRC Region 1
To: Trocine L, Virgilio M
NRC/EDO
References
FOIA/PA-2010-0118
Download: ML101230439 (2)


Text

White, John From:

Collins, Sam Sent:

Monday, November 23, 2009 5:28 PM To:

Trocine, Leigh; Virgilio, Martin Cc:

Mallett, Bruce; Johnson, Michael; Tifft, Doug; Clifford, James; White, John; Barkley, Richard;

  • Barber, Scott

Subject:

OCA Followup Questions: ACTION for 11/21 THREE MILE ISLAND -- Containment Contamination Event Marty, I just talked to Becky and Gene and received positive feedback from the Chairman's briefings of Congressman Holden and Gov. Rendell. The Gov. had a series of followup questions that OCA will provide to OEDO Tues. morning. I suggest that Region I take the lead with the goal of providing responses to the SLO for PA by COB Tues., we will broker with Dave Allard for appropriate context and detail. Gene D. indicated he would forward the questions to me and OEDO. Sam From: Trocine, Leigh Sent: Monday, November 23, 2009 5:12 PM To: Virgilio, Martin; Johnson, Michael; Collins, Sam; Powell, Amy; Dacus, Eugene; Hayden, Elizabeth; Couret, Ivonne; Barber, Scott; Lew, David; Clifford, James; Bellamy, Ronald; White, John; Screnci, Diane; Sheehan, Neil; Barkley, Richard; Tifft, Doug; McNamara, Nancy; Roberts, Darrell; Wilson, Peter Cc: Mallett, Bruce; Andersen, James; Orders, William; Mamish, Nader; Landau, Mindy

Subject:

STATUS -- ACTION for 11/21 THREE MILE ISLAND EVENT -- TMI Public, Federal, Int'l Interest -- Containment Contamination Event Importance: High Hello all, The requested 1-pager (attached) was provided by Region I on short notice and was then forwarded to all of the Commission offices with the caveat that, because of the time constraints, it was provided before the OCA scrub. I also informed them that we have since heard that there may be some minor discrepancies (refinements) with regard to the number of workers receiving doses and that I'll plan to keep them (and you) posted as I learn more information.

Per the Chairman's office request, Region I (Doug Tifft) arranged for Chairman Jaczko to speak directly to the Pennsylvania Governor Ed Rendell. That call is currently in progress.

Please let me know if you need any additional information.

Cheers, Leigh From: Trocine, Leigh Sent: Monday, November 23, 2009 4:57 PM To: Weaver, Doug; Beall, James Cc: Marshall, Michael

Subject:

FYI -- FW: TMI Contamination Event - Chairman's Talking Points -- BEFORE OCA SCRUB Importance: High Hi Doug and Jim, Please refer to the attached file for a 1-Pager that was requested by the Chairman's office in preparation for a 1630 conference call with Congressman Holden. Please bear in mind that, because of the time constraints, it was provided before the OCA scrub. We have since heard that there may be some minor discrepancies 3,4

(refinements) with regard to the number of workers receiving doses. I'll plan to keep you posted as I learn more information., Please let me know if you need any additional information.

Cheers, Leigh From: Trocine, Leigh Sent: Monday, November 23, 2009 3:47 PM To: Marshall, Michael Cc: Powell, Amy; Dacus, Eugene A 4/

Subject:

ACTION FW: TMI Contamination Event - Chairman's Talking Points -- BEFORE OCA SCRUB Importance: High Hi Mike, I understand that the Chairman has a 1600 meeting this afternoon before his. 1630 call and that he'd like to review the 1-Pager ahead of time. As such, I'm forwarding the attached 1-pager, but please bear in mind that OCA just received it as well, so this version has not yet been scrubbed by OCA. We'll get you any changes as soon as we received them.

Cheers, Leigh From: Barber, Scott Sent: Monday, November 23, 2009 3:38 PM To: Trocine, Leigh; Powell, Amy; Dacus, Eugene Cc: Collins, Sam; Lew, David; Clifford, James; Bellamy, Ronald; White, John; Screnci, Diane; Sheehan, Neil; Barkley, Richard; Tifft, Doug; McNamara, Nancy; Roberts, Darrell

Subject:

TMI Contamination Event - Chairman's Talking Points For your review and use.