ML100760469

From kanterella
Jump to navigation Jump to search
Preliminary Notification of Event or Unusual Occurrence - PNO-1-09-006, with Handwritten Notes
ML100760469
Person / Time
Site: Three Mile Island Constellation icon.png
Issue date: 11/24/2009
From: Barber G
NRC Region 1
To:
References
FOIA/PA-2010-0118, PNO-I-09-006
Download: ML100760469 (3)


Text

.01 DCS No.: 0500028911212009 Date: November 24, 2009 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE -- PNO-1-09-006 This preliminary notification constitutes EARLY notice of events of POSSIBLE safety or public interest significance. The information is as initially received without verification or evaluation, and is basically all that is known by the Region I staff on this date.

Facility Exelon Generation Company, LLC Licensee Emerqency Classification Three Mile Island, Unit 1 Notification of Unusual Event Middletown, PA Alert Docket: 50-289 __ Site Area Emergency General Emergency X Not Applicable

SUBJECT:

THREE MILE ISLAND UNIT 1 CONTAMINATION EVE I.*D*I.

At about 4:00 p.m., on November 21, while shut down for a refueling outage and steam generator (SG) replacement, TMI experienced local alarms inside the containment building due to airborne radioactivity levels.

As a precaution in response to the alarms, approximately 175 workers exited the containment.

Several workers alarmed the portal monitors while leaving the radiologically controlled area around the containment building due to contamination levels, and were whole body counted to assess their radiation dose. Of these workers, initially 19 workers received doses ranging from 10 mrem to 38 mrem, which is a very small fraction of the annual federal occupational exposure limit (5000 mrem/yr). It is not unusual for contamination events to occur during refueling outages and workers to be processed as they were in this event.

Exelon attributed the cause of the contamination event to a change in air pressure inside the containment building that dislodged loose surface contamination in primary piping systems.

Some of the contamination became airborne and was detected by local containment air monitors. Exelon surveyed the area around the containment construction opening and did not detect any contamination. The airborne radioactivity readings returned to pre-event levels 4 to 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> after the initial alarms.

There was no effect on public health and safety as a result of this event. This event did not result in exceeding any emergency action levels, nor were any formal event notification criteria met. The workers that were affected by this event received radiation doses that were a small percentage of the annual occupational exposure limit. As a conservative measure, Exelon witheld these workers from future exposure pending detailed evalution.

A number of Region I personnel and Headquarters personnel responded to this event over the weekend. The Resident Inspectors, Health Physics Specialist Inspectors, and the Public Affairs Officer responded to the site to investigate the event and to address media inquires. Exelon issued two press releases, and the NRC issued one press release on the event. The Region I Public Affairs Officershev6esponded to numerous media inquiries. Region I is continuing to follow Exelon's evaluation f this event.

(

The Commonwealth of P as well as several Congressional representatives, were informed of the event.

The information presented herein has been confirmed with the Site Vice President - Three Mile Island, William Noll, and is current as of November 24, 2009 at 2:23 p.m.

This PN is issued for information. only and no updates are anticipated.

ADAMS Accession Number: MLXXXXXXXXX CONTACT: G. Scott Barber (610) 337-5232

DISTRIBUTION: (by email)

Chairman Jazcko Comm. Klein Comm. Svinicki OIP OCA OGC OPA EDO OE NRR SECY IRO NMSS ACRS OIG RES NSIR NRO PDR RSLO Regional Offices By Fax:

DOT:Trans INPO NSAC RI Resident Office Licensee: Exelon Generation Company LLC Three Mile Island, Unit 1 ADAMS Accession Number: MLXXXXXXXXXXX SUNSI Review Complete: (Reviewer's Initials)

DOCUMENT NAME: G:\DRP\PNs\PNO-I-09-006 - TMI Contamination Event.doc After declaring this document "An Official Agency Record" it will be released to the Public.

To receive a copy of this document, indicate in the box: "'=

Copy without attachmentlenclosure,"E"= Copy with attachment/enclosure VN= No copy OFFICE RI/DRP RI/SLO RI/PAO RI/DRP RI/ORA NAME S. Barber D.Tifft D. Screnci J. Clifford S. Collins DATE OFFICIAL RECORD COPY