March 17, 2010

EA-10-004

EA-10-020

Mr. Matthew W. Sunseri, President and

Chief Executive Officer

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

SUBJECT:

RESPONSE TO NOTICE OF VIOLATIONS AND NRC INSPECTION

REPORT 05000482/2009005

Dear Mr. Sunseri:

Thank you for your letter of March 11, 2010, in response to our February 11, 2010, letter and

Notice of Violations regarding the failure to identify and correct leakage from the refueling water

storage tank and to correctly translate the design basis into specifications, drawings and

procedures to prevent the formation of voids in the reactor vessel head during shutdown

operations. We have reviewed your reply and find it responsive to the concerns raised in our

Notice of Violations. We will review the implementation of your corrective actions during a

future inspection to determine that full compliance has been achieved and will be maintained.

Sincerely,

/RA/

Geoffrey Miller, Chief

Project Branch B

Division of Reactor Projects

Docket: 50-482

License: NPF-42

UNITED STATES

NUCLEAR REGULATORY COMMISSION

R E GI ON I V

612 EAST LAMAR BLVD, SUITE 400

ARLINGTON, TEXAS 76011-4125

Wolf Creek Nuclear Operating Corporation

- 2 -

Matthew W. Sunseri, President and

Chief Executive Officer

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

Vice President Operations/Plant Manager

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

Jay Silberg, Esq.

Pillsbury Winthrop Shaw Pittman LLP

2300 N Street, NW

Washington, DC 20037

Supervisor Licensing

Wolf Creek Nuclear Operating Corporation

P.O. Box 411

Burlington, KS 66839

Chief Engineer

Utilities Division

Kansas Corporation Commission

1500 SW Arrowhead Road

Topeka, KS 66604-4027

Office of the Governor

State of Kansas

Topeka, KS 66612-1590

Attorney General

120 S.W. 10th Avenue, 2nd Floor

Topeka, KS 66612-1597

Chairman

Coffey County Courthouse

110 South 6th Street

Burlington, KS 66839

Chief, Radiation and Asbestos

Control Section

Bureau of Air and Radiation

Kansas Department of Health and

Environment

1000 SW Jackson, Suite 310

Topeka, KS 66612-1366

Wolf Creek Nuclear Operating Corporation

- 3 -

Chief, Technological Hazards

Branch

FEMA, Region VII

9221 Ward Parkway

Suite 300

Kansas City, MO 64114-3372

Wolf Creek Nuclear Operating Corporation

- 4 -

Electronic distribution by RIV:

Regional Administrator (Elmo.Collins@nrc.gov)

Deputy Regional Administrator (Chuck.Casto@nrc.gov)

DRP Director (Dwight.Chamberlain@nrc.gov)

DRP Deputy Director (Anton.Vegel@nrc.gov)

DRS Director (Roy.Caniano@nrc.gov)

DRS Deputy Director (Troy.Pruett@nrc.gov)

Senior Resident Inspector (Chris.Long@nrc.gov)

Resident Inspector (Charles.Peabody@nrc.gov)

Site Secretary (Shirley.Allen@nrc.gov)

Branch Chief, DRP/B (Geoffrey.Miller@nrc.gov)

Senior Project Engineer, DRP/B (Rick.Deese@nrc.gov)

Public Affairs Officer (Victor.Dricks@nrc.gov)

Public Affairs Officer (Lara.Uselding@nrc.gov)

Team Leader, DRP/TSS (Chuck.Paulk@nrc.gov)

RITS Coordinator (Marisa.Herrera@nrc.gov)

Senior Enforcement Specialist (Ray.Kellar@nrc.gov)

File located: R:\\_REACTORS\\WC\\2010\\WC NOV Acknowledgement Letter 03-17-10.doc

ML#100760439

SUNSI Rev Compl.

Yes No

ADAMS

Yes No

Reviewer Initials

GBM

Publicly Avail

Yes No

Sensitive

Yes : No

Sens. Type Initials

GBM

PE: DRP/B

C:DRP/B

GTutak

GMiller

/RA/

/RA/

3/16/10

3/17/10

OFFICIAL RECORD COPY

T=Telephone E=E-mail F=Fax