Exek~n Exelon Generation Company, LLC Braidwood Station 35100 South Route 53, Suite 84 Braceville, I L 60407-9619 www.exelOnCOTP.COM Nuclear January 27, 2010 BW100011 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001 Braidwood Station, Unit 2 Facility Operating License No. NPF-77 NRC Docket No. STN 50-457

Subject:

Braidwood Station, Unit 2 Steam Generator Tube Inspection Report for Refueling Outage 14 In accordance with Technical Specification 5.6.9, "Steam Generator (SG) Tube Inspection Report,"

Exelon Generation Company, LLC is reporting the results of the SG inspections that were completed during Braidwood Station, Unit 2 Refueling Outage 14 (A2R14). The attached report is also being submitted in accordance with the requirements of the American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, 2001 Edition through 2003 Addenda,Section XI, "Rules for Inservice Inspection of Nuclear Power Plant Components," Article IWA-6000, "Records and Reports," and Paragraph 11-890.2.3, "Reporting" of ASME Section V "Nondestructive Examination, Article 8 -Appendix II, "Eddy Current Examination of Nonferromagnetic Heat Exchanger Tubing," 2001 Edition through 2003 Addenda.

If there are any questions regarding this submittal, please contact Mr. David Gullott, Regulatory Assurance Manager, at (815) 417-2800.

Respectfully, Amir Shah arami Site Vice President Braidwood Station

Attachment:

Braidwood Station, Unit 2 Steam Generator Tube Inspection Report Refueling Outage 14 cc:

NRC Regional Administrator, Region III NRC Senior Resident Inspector - Braidwood Station Illinois Emergency Management Agency - Division of Nuclear Safety A-0of LJýA

Exelon Generation Company, LLC BRAIDWOOD STATION, UNIT 2 35100 South Rte. 53, Suite 84 Braceville, IL 60407 COMMERCIAL OPERATION: October 17,1988 STEAM GENERATOR TUBE INSPECTION REPORT REFUELING OUTAGE 14 (A2R14)

October 2009 Exelon Generation Company, LLC 200 Exelon Way Kennett Square, PA 19348 Mailing Address 4300 Winfield Road Warrenville, IL 60555 Document Completion Date: January 09, 2010

TABLE OF CONTENTS 1.0 IN T R O D U C T IO N..........................................................................................

1 2.0 S U M M A R Y...................................................................................................

2 3.0 CERTIFICATIONS.....................................................................................

3 3.1 Procedures/Examinations/Equipment............................................

3 3.2 Personnel.....................................................................................

4 4.0 EXAMINATION TECHNIQUES AND EXAMINATION SCOPE.................. 6 4.1 Examination Techniques...............................................................

6 4.2 Steam Generator Inspection Scope..............................................

8 4.3 Recording of Examination Data....................................................

9 4.4 Witness and Verification of Examination.......................................

9 5.0 EXAMINATION RESULTS........................................................................

9 5.1 Indications Found..........................................................................

9 5.2 Other SG Inspection Results........................................................

11 6.0 RESULTS OF CONDITION MONITORING................................................

13 6.1 AVB Wear....................................................................................

14 6.2 Pre-heater Baffle/TSP Wear...........................................................

14 6.3 Foreign Object Wear.....................................................................

15 6.4 Primary to Secondary Leakage Assessment..................................

15 7.0 REPAIR

SUMMARY

16 8.0 DOCUMENTATION..................................................................................

16 9.0 FIGURES/TABLES/ATTACHMENTS.........................................................

17

1.0 INTRODUCTION

Braidwood Station, Unit 2, operates with four Westinghouse Model D-5 recirculating steam generators (SGs) in the four loop pressurized water reactor system. Each SG contains 4570 thermally treated Alloy-600 U-tubes that have a nominal outside diameter of 0.750 inches and a nominal thickness of 0.043 inches. The tubes are hydraulically expanded into the full depth of the tubesheet. The tubes are supported by stainless steel quatrefoil support plates (TSP's) and chrome plated Alloy-600 anti-vibration bars (AVB's). See Figure A.1 for a diagram of the D-5 Steam Generator tube support plate configuration.

Technical Specification (TS) 5.5.9.d provides the requirements for steam generator inspection frequencies. The TS requires that 100% of the Unit 2 tubes are to be inspected at sequential periods of 120, 90 and thereafter 60 effective full power months (EFPM). Additionally, inspect 50% of the tube by the outage nearest the mid-point of the period and the remaining 50% by the refueling outage nearest the end of the period. For Unit 2 during Refueling Outage 14 and subsequent operating cycle, if crack indications are found in any SG tube from 16.95 inches below the top of tubesheet on the hot leg side to 16.95 inches below the top of tubesheet on the cold leg side, then the next inspection for each SG for the degradation mechanism that caused the crack indication shall not exceed 24 EFPM or one refueling outage (whichever is less). A degradation assessment shall be performed to determine the specific inspection scope and inspection methods with the objective of detecting flaws of any type that may be present along the length of the tube.

During the start of Unit 2, Refueling Outage 14 Braidwood was at 86.88 EFPM within the 90 EFPM period. Therefore, Braidwood's Refueling Outage 14 was the end point outage of the 90 EFPM period.

In accordance with Braidwood Station TS 3.4.19, "Steam Generator (SG) Tube Integrity," TS 5.5.9, "Steam Generator (SG) Program," and American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel (B&PV) Code Section Xl 2001 Edition through 2003 Addenda, IWB 2500-1, Examination Category B-Q, Item B16.20, SG eddy current examinations were performed during the Braidwood Station, Unit 2, Refueling Outage 14. All inspections were completed in accordance with TS 5.5.9.d.

The inspections were performed consistent with the Electric Power Research Institute (EPRI) "PWR Steam Generator Examination Guidelines: Revision 7," applicable interim guidance and Nuclear Energy Institute (NEI) 97-06, "Steam Generator Program Guidelines, Revision 2." The field inspection activities were conducted from October 15, 2009 through October 21, 2009 by the Westinghouse Electric Company LLC. The following inspections were performed during this outage (TS 5.6.9.a):

100% bobbin coil eddy current examination of all SGs excluding the Row 1 and Row 2 U-Bend regions. In the Row 1 and Row 2 U-Bend regions a 25% +PointTM inspection was performed as described below.

30% hot leg top of tubesheet (+ 4" to - 3") +PointTM in all SGs.

30% hot leg bulges > 18 volts and over expansions > 1.5 mils within the top 16.95 inches of the hot leg tubesheet in all SGs.

1

30% of the hot leg tubing within the tubesheet (+ 4" to - 18") +PointTM in all SGs.

100% hot leg tubing within the tubesheet (+ 4" to - 18") +PointTM of inservice tubes identified as having increased residual stress.

100% of the hot leg dents/dings > 2.0 volts contained in inservice tubes identified as having increased residual stress, +PointTM.

100% of the wear indications contained in inservice tubes identified as having increased residual stress +PointTM.

+PointTM inspection of all hot leg and cold leg tubesheet expansions transitions significantly outside the tubesheet. (Note: None were identified during A2R1 4).

+PointM inspection of all pre-heater baffle plate expansions significantly above or below the baffle plate. (Note: None were identified during A2R1 4).

20% pre-heater baffle expansion +PointTM in the 2B SG.

o 25% hot leg dents/dings >3.0 volts +PointM in all SGs.

25% Row 1 and Row 2 U-bends +PointTM in all SGs.

100% visual inspection of the previously installed and newly installed tube plugs in all SGs.

2.0

SUMMARY

The guidance in Revision 7 of the EPRI PWR Steam Generator Examination Guidelines (i.e., EPRI Guidelines and applicable interim guidance) was used during the inspection.

A degradation assessment was performed prior to the inspection to ensure the proper EPRI Guidelines Appendix H, "Performance Demonstration for Eddy Current Examination," or Appendix I, "NDE System Measurement Uncertainties for Tube Integrity Assessments," qualified inspection techniques were used to detect any existing and potential modes of degradation. Each technique was evaluated to ensure that the detection and sizing capabilities are applicable to the Braidwood Station Unit 2 site-specific condition in accordance with the EPRI Guidelines. All data analysts were qualified to Appendix G, "Qualification of Eddy Current Examination Personnel for Analysis of Eddy Current Examination Data," of the EPRI Guidelines (i.e., Qualified Data Analyst (QDA)). All data analyst and acquisition personnel satisfactorily completed site-specific training and testing prior to beginning examinations. An independent QDA process control review was employed to randomly sample the data to ensure that the analysis resolution process was properly performed and that the field calls were properly reported. An analysis feedback process was implemented that required the data analysts to review their missed calls and overcalls on a daily basis.

The modes of tube degradation found during A2R1 4 were Anti-Vibration Bar (AVB) wear, pre-heater tube support plate wear and secondary side foreign object wear.

On October 16, 2009, prior to completion of steam generator inspection, the NRC approved Braidwood TS Amendment No. 161. This amendment allowed that during Braidwood Station, Unit 2 Refueling Outage 14, (i.e., A2R14) and the subsequent operating cycle, tubes with service-induced flaws located greater than 16.95 inches below the top of tubesheet do not require plugging or repair. Tubes with service-induced flaws located in the portion of tube from the top of tubesheet to 16.95 inches below the top of tubesheet shall be plugged or repaired upon detection. During the Braidwood Station, Unit 2 Refueling Outage 14, no service-induced flaws were identified within the portion of tube from the top of tubesheet to the inspection depth of 18 inches below the top of tubesheet.

2

As a result of the eddy current inspection of the SGs, a total of six tubes were removed from service by mechanical tube plugging. Of the six tubes removed from service, one tube was plugged due to having AVB wear greater than or equal to the 40% through wall (TW) TS 5.5.9.c.1 acceptance criteria, and five tubes were preventatively plugged due to having wear from secondary side foreign objects, which were below the 40% TW TS 5.5.9.c.1 acceptance criteria. Pursuant to EPRI Guideline Section 3.7, "Classification of Sample Plan Results," the results of the inspection were classified as inspection category C-1 for the 2A, 2C and 2D SGs and category C-2 for the 2B SG. There were no scanning limitations during the examinations.

Table 2.1 provides the tube plugging levels for each SG. Table 2.2 provides the total number of tubes plugged during A2R14 by degradation mode.

Table 2.1 Equivalent Tube Plugging Level (TS 5.6.9.f & TS 5.6.9.h)

Tubes Previously Plugged 83 49 65 26 223 Tubes Plugged in A2R14 0

5 1

0 6

Total Tubes Plugged 83 54 66 26 229 Total Tubes Plugged (%)*

1.82%

1.18%

1.44%

0.57%

1.25%

  • Each SG contains 4570 tubes Table 2.2 Tubes Plugged During A2R14 (TS 5.6.9.e)

Foreign Object Wear 0

4 1

0 5

Anti-Vibration Bar Wear 0

1 0

0 1

A2R14 Plugging Totals 0

5 1

0_6 3.0 CERTIFICATIONS 3.1 Procedures/Examinations/Equipment 3.1.1 The examination and evaluation procedures used during the SG eddy current inspection were approved by personnel qualified to ECT Level III in accordance with the 1984 Edition of the American Society for Nondestructive Testing (ASNT) Recommended Practice SNT-TC-1A, "Personnel Qualification and Certification in Nondestructive Testing" or the 1991 and 1995 Editions of the American National Standards Institute (ANSI)/ASNT CP-189, "ASNT Standard for Qualification and Certification of Nondestructive Testing Personnel." Exelon Generation Company, LLC (i.e., EGC) Procedure ER-AP-335-039, "Multifrequency Eddy Current Data Acquisition of Steam Generator Tubing," Revision 6 and EGC Procedure ER-AP-335-040, "Evaluation of Eddy Current Data for Steam Generator Tubing," Revision 5, were used for data acquisition and analysis.

3

3.1.2 The examinations, equipment and personnel were in compliance with the requirements of EGC and Westinghouse Quality Assurance Programs for Inservice Inspection; Braidwood Station TS 5.5.9; 2001 Edition through 2003 Addenda of ASME Boiler and Pressure Vessel Code Sections Xl, "Rules for Inservice Inspection of Nuclear power Plant Components," and Section V, "Nondestructive Examination"; EPRI PWR SG Examination Guidelines, Revision 7; and NEI 97-06, "Steam Generator Program Guidelines," Revision 2.

3.1.3 Certification packages for examiners, data analysts and equipment are available at Braidwood Station. Tables A. 1 and A.2 of Attachment A lists all personnel who performed, supervised, or evaluated the data during this SG inservice inspection.

3.1.4 CoreStar International Corporation OMNI-200 TM Remote Data Acquisition Units (RDAUs) with Westinghouse ANSER 8.4.3 Revision 364 computer software was used to acquire the eddy current data. Analysis was performed with Westinghouse ANSER 8.4.3 Revision 366 computer software.

3.1.5 The bobbin coil examinations of the SGs were performed with 0.610 inch diameter bobbin coil eddy current probes. For low row U-Bend tubing, 0.590 inch diameter probes were utilized where there was difficulty using the 0.610 inch diameter probe.

3.1.6 The top of tubesheet, tubesheet region, baffle plate expansion, and special interest rotating coil examinations were performed with a 0.610 inch diameter three coil rotating +PointTM probe that contained a plus-point coil, a 0.115 inch diameter pancake coil and a 0.080 inch diameter pancake coil.

3.1.7 The rotating coil examinations in the U-Bend region were performed with a 0.580 inch diameter rotating +PointTM probe.

3.2 Personnel 3.2.1 The personnel who performed the SG eddy current inspections were qualified to Level I and Level II certification in accordance with the 1984 Edition of the ASNT Recommended Practice SNT-TC-1A, "Personnel Qualification and Certification in Nondestructive Testing" or the 1995 Edition of ANSI/ASNT CP-1 89, "ASNT Standard for Qualification and Certification of Nondestructive Testing Personnel." The Level I personnel performed the inspections under the direct supervision of Level II or Level III personnel. A list of the certified eddy current personnel who performed data acquisition for the examination is contained in Table A. 1 of Attachment A.

3.2.2 The personnel who performed the SG eddy current data analysis were qualified to a minimum of Level II, with special analysis training (i.e., Level IIA) in accordance with the 1984 Edition of the ASNT Recommended Practice SNT-TC-1A, "Personnel Qualification and Certification in Nondestructive Testing" or the 1995 Edition of ANSI/ASNT CP-1189, "ASNT 4

Standard for Qualification and Certification of Nondestructive Testing Personnel." A list of the certified eddy current personnel who performed data analysis for the examination is contained in Table A.2 of Attachment A.

3.2.3 All eddy current data analysts were qualified in accordance with EPRI Guidelines Appendix G for Qualified Data Analysts (QDAs). In addition, all data analysts were trained and tested in accordance with a site specific performance demonstration program in both the bobbin coil and

+PointTM inspection data analysis. Resolution analysts were also trained and tested specifically for the performance of data resolution. All analysts were required to achieve a minimum score of 80% Probability of Detection (POD) with a 90% minimum confidence level on the practical examination, and a minimum score of 80% on the written examination prior to analyzing data.

3.2.4 All SG eddy current data acquisition personnel were trained and tested in accordance with a site specific performance demonstration program. The data acquisition operators were required to achieve a written test score of 80% or greater prior to acquiring data.

3.2.5 The SG eddy current analysis was subject to two independent analyses.

Westinghouse and sub-contractor companies performed primary analysis of all data. Anatec and sub-contractor companies, different than those used on primary analysis, performed secondary analysis of all data.

Discrepancies between the two parties required Level III concurrence between both parties for the final resolution.

3.2.6 Two independent SG eddy current Level III QDA's were employed to serve as process control reviewers, in accordance with EPRI Guidelines.

The Independent Level III QDA's randomly sample the data to ensure the resolution process was properly performed and that the field calls were properly reported. The Independent Level III QDA's also provided data acquisition oversight to ensure that the data collection process was in compliance with appropriate procedures, that all essential variables were set in accordance with the applicable Examination Technique Specification Sheet (ETSS) and to provide a data quality check of acquired data. The Independent Level III QDA's reported directly to the EGC Level III inspector.

3.2.7 Personnel qualified as data analysts performed real time data quality verifications.

5

4.0 EXAMINATION TECHNIQUES AND EXAMINATION SCOPE All SG eddy current examination techniques used were qualified in accordance with Appendix H or Appendix I of the EPRI PWR SG Examination Guidelines. Each examination technique was evaluated to be applicable to the tubing and conditions of the Braidwood Station, Unit 2 SGs.

4.1 Examination Techniques (TS 5.6.9.c) 4.1.1 The bobbin coil examinations were performed with a 0.610 inch diameter bobbin coil eddy current probe as described in Section 3.1.5. For low row U-Bend regions where there was difficulty using the 0.610 inch diameter probe, a 0.590 inch diameter probe was utilized where there was difficulty traversing the U-Bend region. The nominal probe inspection speed was 40 inches per second for rows 5 through 49 and 24 to 40 inches per second for rows 1 through 4 depending on tube conditions. Sufficient sampling rates were used to maintain a minimum of 33 samples per inch. The bobbin coil probes were operated at frequencies of 550 kHz, 300 kHz, 130 kHz, and 20 kHz operating in the differential and absolute test modes. In addition, suppression mixes were used to enhance the inspection. These mixes were as follows: 550/130 kHz differential mix, a 550/300/130 kHz differential mix, and a 300/130 kHz absolute mix.

4.1.2 The +PointTM examinations at the top of tubesheet, within the tubesheet, pre-heater baffle plate expansion transition regions, dents/dings and special interest locations were performed with a 0.610 inch diameter three coil +PointTM eddy current probe as described in Section 3.1.6. The nominal probe speed was 0.8 inches per second and 0.1 inches per second for the examination of dent and dings. For the tube expansion regions and special interest regions a sampling rate was used to maintain a minimum of 30 samples per inch in the circumferential direction and 25 samples per inch in the axial direction. For the dent/ding regions a sampling rate was used to maintain a minimum of 30 samples per inch in the circumferential direction and 30 samples per inch in the axial direction. The rotating probes were operated at frequencies of 300 kHz, 200 kHz, 100 kHz and 20 kHz. In addition to the four base frequencies, four process channels were used to display circumferential indications in the positive trace and to provide a suppression mix for the support plates.

4.1.3 The +PointM examinations within the low row U-Bend regions were performed with a 0.580 inch diameter +PointTM eddy current probe as described in Section 3.1.7. Nominal probe speed was 0.4 inches per second. A sampling rate was used to maintain a minimum of 30 samples per inch in the circumferential direction and 30 samples per inch in the axial direction. The rotating probes were operated at frequencies of 400 kHz, 300 kHz, 150 kHz and 20 kHz. In addition to the four base frequencies, four process channels were used to display circumferential indications in the positive trace and to provide a suppression mix for the anti-vibration bars.

6

4.1.4 The eddV current calibration standards used for the bobbin coil and

+Point inspections met the requirements of the EPRI PWR Steam Generator Examination Guidelines, Revision 7 and Sections V and Xl of the ASME Boiler and Pressure Vessel Code, 2001 Edition through 2003 Addenda.

4.1.5 The SG eddy current examination techniques used during this inspection were equivalent to the EPRI Appendix H or Appendix I techniques listed in Table 4.1 below. Each ETSS was evaluated and determined to be applicable to the site conditions.

TABLE 4.1 APPENDIX H/APPENDIX I TECHNIQUES AVvi/i-Flaws 96043.2 1

Bobbin Single Land TSP Wear 128425 2

+Point' Axial ODSCC Detection at Top of Tubesheet/ Expansion Transition Regions/Broached TSPs/Dent/ Ding 128432 1

+PointTM Axial ODSCC Sizing at Top of Tubesheet/Expansion Transition Regions/Broached TSPs/Dent/Dings 96910.1 10

+Point' Tapered TSP Wear/Foreign Object Wear/Free Span Volumetric Indications 96005.2 9

Bobbin Freespan Pitting 21998.1 4

+PointTM Foreign Object Wear/Freespan Flaw Sizing 20511.1 8

+PointTM Axial PWSCC at TTS Expansion/Tubesheet/

Pre-Heater Expansion/Dent/Ding/Deplugged Tube 20510.1 7

+PointTM Circumferential PWSCC at TTS Expansion/

Tubesheet/Pre-Heater Expansion/Dent /Ding/ Deplugged Tube 128424 2

+PointM Axial ODSCC Detection at Sludge Pile Region/ Drilled TSPs/Baffle Expansions 128431 1

+PointM Axial ODSCC Sizing at Sludge Pile Region/Drilled TSPs/Baffle Expansions 21410.1 6

+PointM Circumferential ODSCC at TTS Expansion/Dent/ Ding/

Pre-Heater Expansion 22401.1 4

+PointTM Axial ODSCC at Dent/Ding 96511.1 16

+Pointm Axial and Circumferential PWSCC at Low Row U-Bend 96703.1 17

+PointTM Axial PWSCC at Dent/Ding 128413 2

Bobbin Axial ODSCC Detection at Sludge Pile/Freespan/

Broached TSP 128411 2

Bobbin Axial ODSCC Detection at Drilled TSP PWSCC - Primary Water Stress Corrosion Cracking ODSCC - Outer Diameter Stress Corrosion Cracking TSP - Tube Support Plate TTS - Top of Tubesheet AVB - Anti-Vibration Bar 7

4.2 Steam Generator Inspection Scope (TS 5.6.9.a) 4.2.1 100% of the tubes in all four SGs were inspected full length, with a bobbin coil probe as described in Section 4.1.1, with the exception of the Row 1 and Row 2 U-Bend region where a 25% sample was performed with a

+PointTM probe as described in Section 4.1.3.

4.2.2 30% of the tubes in all four SGs were inspected in the hot leg tubesheet region from 4 inches above the top of tubesheet expansion transition to 18 inches below the top of tubesheet with a +PointTM robe as described in Section 4.1.2. This population included 30% of the hot leg bulges > 18 volts and over expansions > 1.5 mils within the top 16.95 inches of the hot leg tubesheet.

4.2.3 100% of the tubes identified in all four SGs as having increased residual stress (total of 71 tubes) were inspected in the hot leg tubesheet region from 4 inches above the top of tubesheet expansion transition to 18 inches below the top of tubesheet with a +PointM probe as described in Section 4.1.2. Additionally, all hot leg dents/dings > 2.0 volts, (total of 4 indications) and any wear indications (total of 0) identified in these tubes were inspected with a +PointTM probe as described in Section 4.1.2.

4.2.4 20% of the pre-heater baffle plate expansion transitions (+/- 3 inches) in the 2B SG were inspected with a +PointTM probe at baffle plates 02C and 03C as described in Section 4.1.2. Additional pre-heater baffle plate expansion transitions (+/- 3 inches) were inspected in the 2B, 2C and 2D SGs with a +PointTM probe as described in Section 4.1.2, at baffle plate 02C in the outer peripheral tubes near the flow blocking region of the pre-heater. This location has historically been known as an area where secondary side foreign objects may collect due to the flow conditions in the region.

4.2.5 25% of the hot leg dents/dings > 3.0 volts based on bobbin inspection results, were inspected (+/- 3 inches) in all four SGs with a +PointM probe as described in Section 4.1.2.

4.2.6 25% of the Row 1 and Row 2 U-Bends in all four SGs were inspected from the top support plate on the hot leg side to the top support plate on the cold leg side with a +PointTM probe as described in Section 4.1.3.

4.2.7 100% +PointTM inspection of all hot leg and cold leg tubesheet expansions transitions significantly outside the tubesheet, and pre-heater baffle plate expansions significantly above or below the baffle plate, as determined by review of bobbin eddy current data. Note: No expansion transitions significantly outside the tubesheet or pre-heater baffle plate were identified during the A2R14 SG inspection.

4.2.8 Diagnostic examinations were conducted on non-quantifiable indications that were detected by the bobbin coil examination. Diagnostic examinations were also conducted on tubes in the vicinity of potential foreign objects in order to determine the extent of tubes potentially 8

affected by the objects. These examinations were performed with a

+PointTM as discussed in Section 4.1.2.

4.2.9 See Attachment B for tubesheet maps detailing the inspection scopes for each SG.

4.3 Recording of Examination Data The eddy current data and analysis results were recorded on hard drives. The data was then loaded into the Westinghouse Eddy Current Data Management System, "ST Max" Version 1.24.02. This system was used to track the completion of the examinations and was used to generate the final SG eddy current report summaries.

4.4 Witness and Verification of Examination SG eddy current inspections were witnessed and/or verified by the Authorized Nuclear Inservice Inspectors, Mr. L. Malabanan and Mr. R. White of the Hartford Steam Boiler Inspection and Insurance Company of Hartford Connecticut, Chicago Branch, 2443 Warrenville Road, Suite 500, Lisle, Illinois 60532-9871.

5.0 EXAMINATION RESULTS 5.1 Indications Found (TS 5.6.9.b) 5.1.1 Anti-Vibration Bar (AVB) Wear-Tube degradation was found during bobbin coil examination in the U-Bend region due to fretting of Anti-Vibration Bars on the outer surface of the tube. A total of 896 indications were reported. The EPRI Appendix H bobbin coil technique 96004.3, Revision 12 was utilized for depth sizing of all AVB wear. The largest indication was 41% TW. One tube had an indication of AVB wear greater than or equal to 40% TW and was removed from service by mechanical tube plugging. Table 5.1.1 provides a summary of AVB wear degradation. Refer to Attachment B.5 for detailed locations and sizing for all AVB wear indications.

Table 5.1.1 A2R14 AVB Wear Summary SG 2A,, :SG-2B SG2C'ý SG 2D nd.

And Jnd..

Ind.

<20% TW 224 50 133 93 20-39% TW 150 57 108 80

>= 40% TW 0

1 0

0 TOTAL 374 108 241 173 9

5.1.2 Foreign Object Wear - EPRI Appendix H +PointTM coil sizing technique 21998.1, Revision 4 was used to size indications of secondary side foreign object wear identified during A2R14. A total of 14 indications of secondary side foreign object wear were identified in 13 tubes. The indications ranged from 9% TW to 37% TW. Five indications had been identified in previous outages and were allowed to remain in service based on being below the TS plugging limit and visual verification that the object(s) that had caused the wear were no longer present. Inspection of these locations during A2R1 4 confirmed that these wear indications had not grown since originally identified, therefore the tubes remain in service.

Three tubes in SG 2A were identified during A2R14 that contained secondary side foreign object wear indications just above the first support plate on the hot leg side. The area where the above wear indications occurred was made accessible for visual inspection during A2R1 4.

Secondary side visual inspection identified a small metal slag remnant adjacent to the worn tubes which measured approximately 0.2" x 0.15" x 0.2". The object was successfully removed from the 2A SG. The inservice tubes surrounding the above tubes were inspected with

+PointTM. No additional tube wear or evidence that a foreign object remains in the area was identified. Since the secondary side foreign object that caused the tube wear was removed from the 2A SG, and the tube wear indications were less than the TS plugging limit these three tubes were allowed to remain in service.

Table 5.1.2 provides a summary of the tubes that contain indication of secondary side foreign object wear as identified during A2R1 4.

10

Table 5.1.2 A2R14 Forei Obect Wear Summary 2A 30 53 01H + 0.55" 9%

Object Removed During A2R14 2A 31 52 01H + 0.43" 26%

Object Removed During A2R14 2A 32 53 01H + 0.36" 14%

Object Removed During A2R14 2A 42 22 02C + 0.72" 14%

Historical - No Change - Object No Longer Present 2B 13 38 07H - 0.70" 18%

Location Not accessible - Tube Plugged/Stabilized 2B 19 67 05H - 0.78" 19%

Location Not accessible - Tube Plugged/Stabilized 2B 21 65 05H - 0.63" 34%

Location Not accessible - Tube Plugged/Stabilized 2B 30 56 07H - 0.74" 15%

Location Not accessible - Tube Plugged/Stabilized 2B 49 51 TSC + 0.61" 24%

Historical - No Change - Object No Longer Present 2B 49 52 TSC + 0.96" 37%

Historical - No Change - Object No Longer Present 2B 49 52 TSC + 0.44" 25%

Historical - No Change - Object No Longer Present 2C 10 3

08H - 0.98" 20%

Location Not accessible - Tube Plugged/Stabilized 2D 31 48 01H + 0.43" 19%

Historical - No Change - Object No Longer Present Verified Object Not Present During A2R14 - No 2D 36 61 TSH + 0.02" 16%

Change Compared to A2R13 All newly identified indications of secondary side foreign object wear received additional +PointTM inspection of the surrounding tubes to make certain that the wear region was adequately bounded. As shown in Table 5.1.2 above, tubes that contained indications of secondary side foreign object wear in regions that were not accessible for visual inspection were conservatively stabilized through the region of wear and plugged regardless of the flaw size.

Refer to Attachment B.4 for detailed locations and sizing for all foreign object wear indications.

5.1.3 Pre-heater Wear - Tube degradation was found in six tubes that was attributable to pre-heater baffle/tube support plate wear. The depth of the pre-heater wear ranged from 5% TW to 36% TW. The depth was measured by either EPRI Appendix H qualified bobbin coil technique 96004.3, Revision 12 if the wear was at a drilled hole support, or bobbin coil technique 96043.2, Revision 1 if the wear was at a quatrefoil hole support location. Since no indications exceeded the TS plugging limit, no tube plugging was required for this damage mechanism. Refer to Attachment B.6 for detailed locations and sizing for all pre-heater wear indications.

5.2 Other SG Inspection Results 5.2.1 Inspection of Tubes that Potentially Contain Higher Residual Stress -

Prior to the start of A2R14, Braidwood had 71 tubes inservice that were previously screened as potentially containing higher residual stress. This 11

screening was performed in response to a fabrication anomaly that was found at another plant containing thermally treated Alloy-600 tubing, which was linked to the development of stress corrosion cracking of the tubes at the support plate intersections. The following inspections were performed during A2R14 on the 71 tubes that could potentially contain higher residual stress:

o Full Length bobbin coil inspection as described in Section 4.1.1.

o Hot leg tubesheet inspection (+ 4 inches to - 18 inches) with a

+PointTM probe as described in Section 4.1.2.

o Inspection of all hot leg dents and dings > 2.0 volts with a +PointTM probe as described in Section 4.1.2. (Note: Four indications met this criteria in these tubes).

o Inspection of all wear indications with a +PointM probe as described in Section 4.1.2. (Note: No wear indications were identified in these tubes.)

No indications of stress corrosion cracking or other degradation were identified in the inspection scope as described above.

5.2.2 Tubesheet Region Inspection Results - 30% of the tubes in all four SGs were inspected in the hot leg tubesheet region from 4 inches above the top of tubesheet expansion transition to 18 inches below the top of tubesheet with a +PointTM probe as described in Section 4.1.2. This population included 30% of the hot leg bulges > 18 volts and over expansions > 1.5 mils within the top 16.95 inches of the hot leg tubesheet. No indications of stress corrosion cracking were identified in this inspection scope.

During A2R1 4 all hot leg and cold leg tubes were monitored for tube slippage within the tubesheet region in accordance with industry developed guidance. Tube axial displacement (slippage) monitoring was performed to ensure tubes had not severed within the tubesheet in regions of the tubesheet that were not required to be inspected with +PointTM. No tubes were identified as having tube slippage during A2R14 (TS 5.6.9.1).

Prior to the start of A2R1 4, historical eddy current data was reviewed for all tubesheet expansion transitions to locate any significant deviations in the distance from the top of the tubesheet to the bottom of the expansion transition (BET). No significant BET measurements were identified (Regulatory Commitment).

5.2.3 Visual Inspection of Installed Tube Plugs - All previously installed tube plugs were visually inspected for signs of degradation and leakage. In addition, all plugs installed during this outage (A2R14) were also visually inspected and the installation parameters were reviewed for acceptable installation. No anomalies were found.

5.2.4 Attachment B contains tube lists with location and orientation of all imperfections that contain measurable through wall depth that were found during the A2R14 eddy current inspection (TS 5.6.9.d).

12

5.2.5 No tubes were identified with hot leg or cold leg tubesheet expansions transitions significantly outside the tubesheet, additionally no pre-heater baffle plate expansions were identified significantly above or below the baffle plate, as determined by review of bobbin eddy current data.

5.2.6 Visual inspections of the secondary side moisture separator region of the 2B and 2C SGs were performed during the A2R14 outage. The inspections were performed in accordance with Westinghouse procedure MRS-SSP-1323-CBE/CDE, "Model D-5 SG Steam Drum and Auxiliary Feedwater Nozzle/Piping Inspection at Byron Station, Unit 2, and Braidwood Station, Unit 2," Revision 2. This was a follow-up inspection of the 2B and 2C SGs based on erosion of the moisture separator tangential nozzles, downcomer barrels and swirl vanes being identified during the previous outage (A2R1 3), refer to the previous Braidwood Unit 2 Thirteenth Refueling Outage Steam Generator Inservice Inspection Summary Report, dated November 11, 2008.

During the A2R14 inspection ultrasonic thickness measurements were taken of the eroded areas, with an emphasis on reinspection of the areas identified as eroded in the 2B and 2C SGs during the previous A2R1 3 inspection. Continued erosion of the components was identified in the 2B and 2C SGs, while no indications of through wall erosion were identified.

Similar extent of corrosion was found in both SGs. The bounding wear measurement in the 2B SG showed a maximum wall loss of 47%, and the bounding wear measurement in the 2C SG showed a maximum wall loss of 38%, as compared to the original manufacturing nominal value. An analysis was performed that determined that in the eroded areas significant margin remained prior to the erosion penetrating through wall and affecting SG performance or possibly generating loose parts. The erosion in the affected areas was not projected to penetrate through wall, create loose parts, or impact SG performance prior to the next inspection of the region. Monitoring of the condition is planned over subsequent operating cycles in order to develop a degradation growth rate and take corrective actions if they become necessary.

6.0 RESULTS OF CONDITION MONITORING (TS 5.6.9.g)

A condition monitoring assessment was performed for each inservice degradation mechanism found during the A2R14 SG inspection. The condition monitoring assessment was performed in accordance with TS 5.5.9.a and NEI 97-06 using the EPRI Steam Generator Integrity Assessment Guidelines, Revision 2. For each identified degradation mechanism, the as-found condition was compared to the appropriate performance criteria for tube structural integrity, accident induced leakage and operational leakage as defined in TS 5.5.9.b. For each damage mechanism a tube structural limit was determined to ensure that SG tube integrity would be maintained over the full range of normal operating conditions and design basis accidents. This includes retaining a safety factor of 3.0 against burst under normal steady state full power operation primary to secondary pressure differential and a safety factor of 1.4 against burst under the limiting design basis accident pressure differential. The structural limit was also based on using the draft Regulatory Guide 1.121 methodology for uniform wall thinning of unlimited length using ASME Code minimum material 13

properties. Satisfying the structural limit ensures that the SG tube integrity performance criteria for structural integrity, accident induced leakage and operational leakage will be maintained.

The as-found condition of each degradation mechanism found during the A2R1 4 outage was shown to meet the appropriate limiting structural integrity performance parameter with a probability of 0.95 at 50% confidence, including consideration of relevant uncertainties.

No tube pulls or in-situ pressure tests were performed during A2R14.

Sections 6.1 through 6.3 provide a summary of the condition monitoring assessment for each degradation mechanism. Section 6.4 provides a primary to secondary leakage assessment as required by TS 5.6.9.j and TS 5.6.9.k.

6.1 AVB Wear The largest AVB wear indication found during the A2RI 4 inspection was 41%

TW as measured by the EPRI Appendix H qualified technique 96004.3, Revision

12. Considering technique and analyst uncertainties, the largest AVB wear indication found is corrected to 48.3% TW with a 0.95 probability at 50%

confidence. This is below the AVB wear structural limit of 71.4% TW.

6.2 Pre-Heater Baffle/TSP Wear The largest pre-heater baffle plate drilled hole wear indication found during the A2R14 inspection was 6% TVV as measured by the EPRI Appendix H qualified technique 96004.3, Revision 12. Since the Braidwood A2R14 EPRI Appendix H Qualification report determined that the signal to noise ratio may influence detection of indications less than 14.5% TIW, it was conservatively assumed at a 14.5% TW indication could be present but not detected. Therefore it was conservatively assumed that a 14.5% TW indication was the largest indication remaining in service. Considering technique and analyst uncertainties, this indication is corrected to 22.8% TW with a 0.95 probability at 50% confidence.

This is below the 0.75-inch baffle plate wear structural limit of 65.6% TW.

The largest single land TSP quatrefoil wear indication found during the A2R14 inspection was 36% TW as measured by the EPRI Appendix H qualified technique 96043.2, Revision 1. Considering technique and analyst uncertainties, the largest single land TSP wear indication found is corrected to 40.5% TW with a 0.95 probability at 50% confidence. This is below the 1.12 inch TSP wear structural limit of 60.7% TW.

6.3 Foreign Object Wear The largest foreign object wear indication found during the A2R1 4 inspection was 37% TW as measured by the EPRI Appendix H qualified technique 21998.1, Revision 4. This indication had not changed since the previous refueling outage (A2R13) inspection. This tube has been allowed to remain in service based on being below the TS plugging limit and visual verification that the object(s) that 14

had caused the wear were no longer present, additional detail is provided in Section 5.1.2. Considering technique and analyst uncertainties, the foreign object wear is corrected to 55.1% TW with a 0.95 probability at 50% confidence.

This is below the 58.1% TW freespan uniform wall thinning of unlimited length structural limit.

6.4 Primary to Secondary Leakage Assessment (TS 5.6.9.j and TS 5.6.9.k)

Braidwood TS 5.6.9.j reporting requirement states:

"For Unit 2 following completion of an inspection performed in Refueling Outage 14 (and any inspections performed in the subsequent operating cycle), the operational primary to secondary leakage rate observed (greater than three gallons per day) in each steam generator (if it is not practical to assign the leakage to an individual steam generator, the entire primary to secondary leakage should be conservatively assumed to be from one steam generator) during the cycle preceding the inspection which is the subject of the report,"

Braidwood Station, Unit 2 did not observe any operational SG primary to secondary leakage over the preceding cycle. This is based on chemistry sampling taken from the Steam Jet Air Ejector and liquid SG blowdown sample locations.

Braidwood TS 5.6.9.k reporting requirement states:

"For Unit 2 following completion of an inservice inspection performed in Refueling Outage 14 (and any inspections performed in the subsequent operating cycle), the calculated accident induced leakage rate from the portion of the tubes below 16.95 inches from the top of the tubesheet for the most limiting accident in the most limiting SG. In addition, if the calculated accident induced leakage rate from the most limiting accident is less than 3.11 times the maximum operational primary to secondary leakage rate, the report should describe how it was determined,"

Regarding Condition Monitoring requirements, since Braidwood Station, Unit 2 did not observe any SG primary to secondary operational leakage, the calculated accident leakage rate from flaws below 16.95 inches from the top of the tubesheet would also not be quantifiable.

Regarding Operational Assessment requirements, Braidwood Station, Unit 2 did not observe any SG primary to secondary operational leakage during Cycle 14.

Further, no degradation that may lead to leakage was detected above 16.95 inches from below the top of the tubesheet region during A2R14. This is evidenced by all degradation modes identified during A2R14 being below the tube uniform wall thinning structural limits of unlimited length as described in Sections 6.1, 6.2 and 6.3. Therefore, the entire allowable accident induced leakage (0.5 gallons per minute Room Temperature (gpmRT)) at Braidwood Station, Unit 2 can be allocated to the tubesheet expansion region over the next cycle of operation. Using the calculation basis above, the allowable normal accident induced leakage from the tubesheet expansion region is 0.16 gpmRT (0.5 gpmRT divided by 3.11), which is greater than the 150 gpdRT (0.104 15

gpmRT) TS 3.4.13 primary to secondary leakage limit for Braidwood Station, Unit

2. Therefore, no adjustment of the TS 3.4.13 limit for normal operating leakage is required, and accident conditional leakage limits are maintained by adherence to TS 3.4.13.

7.0 REPAIR

SUMMARY

(TS 5.6.9.i)

Repairs were conducted in accordance with ASME Section XI, 2001 Edition through 2003 Addenda. All tube plugging was performed by Westinghouse using an Alloy 690 mechanical tube plugging process in accordance with ASME Section XI IWA-4713, "Heat Exchanger Tube Plugging by Expansion." All repairs were performed in accordance with Westinghouse approved procedures. Table 7.0 summarizes the repairs performed during A2R1 4. No tube sleeving was performed.

Table 7.0 Summary of A2R14 Tube Plugging Tubes Plugged in A2R14 0

5 1

0 6

Tubes Stabilized 0

4 1

0 5

Refer to Attachment B for detailed locations and sizing of indications in tubes that were plugged during A2R14.

8.0 DOCUMENTATION All original data is stored on optical disks that have been provided to EGC and are maintained at Braidwood Station. The final data sheets and pertinent tube sheet plots are contained in the Westinghouse Outage Report for Braidwood Unit 2, Fourteenth Refueling Outage, and are also maintained at Braidwood Station.

NOTE: The ASME Section XI NIS-1 Form, "Owner's Report for Inservice Inspections," and NIS-2 Forms, "Owner's Report for Repair / Replacement Activities," for steam generator inspection activities performed during the Braidwood Station, Unit 2 Refueling Outage 14 are being transmitted separately with the "Braidwood Station, Unit 2 Inservice Inspection Summary Report."

16

9.0 FIGURES/TABLES/ATTACHMENTS Attachment A Contents Table A.1 Data Acquisition Personnel Certification List Table A.2 Data Analysis Personnel Certification List Figure A.1 Westinghouse Model D-5 Tube Support Plate Attachment B Contents Attachment B.1 As-tested Bobbin Inspection Maps Attachment B.2 As-tested +PointTM Inspection Maps Attachment B.3 As-tested +PointTM Special Interest Inspection Maps Attachment B.4 Tubes Containing Secondary Side Foreign Wear Attachment B.5 Tubes Containing Anti-Vibration Bar Wear Attachment B.6 Tubes Containing Pre-heater Wear Attachment B.7 Tubes Repaired During A2R14 17

Attachment A Personnel Certifications

TABLE A.1 A2R14 Data Acquisition Personnel Certifications Nane mLevel QDA*,

1 Chiplaskey, G.

Westinghouse II No 2

Fore, S.

Westinghouse II No 3

Gallagher, D.

Westinghouse I

No 4

Gault, W.

Westinghouse II No 5

Hazlet, W.

System One II No 6

Kuyat, B.

System One II No 7

Lopez, P.

System One I

No 8

Mardell, D.

Westinghouse II No 9

McElhinny, J.

Westinghouse II No 10 Scott, A.

Westinghouse II No 11 Shaffer, E.

Master-Lee IIA No 12 Spires, A.

System One I

No 13 Vernon, D.

Westinghouse II No 14 Yererall, R.

System One I-L No

  • EPRI Guidelines Appendix G Qualified Data Analyst

TABLE A.2 A2R14 Data Anal sis Personnel Certifications No..

Name Cdompany Level-QDA* (YiIN) 1 Alspaugh, K.

NDE Tech III Yes 2

An, C.

SAE-ON IIA Yes 3

Belville, C.

Wiltec IIA Yes 4

Black, C.

NDE Tech III Yes**

5 Bowler, S.

Wiltec IIA Yes 6

Brown, M.

NDE Tech III Yes**

7 Calendar, D.

Wave III Yes 8

Caperello, M.

Anatec IIA Yes 9

Cvitanovic, N.

HRID IIA Yes 10 Do, H.

KPS IIA Yes 11 Draganov, M.

HRID IIA Yes 12 Dugas, K.

Areva IIA Yes 13 Dykes, R.

Anatec IIA Yes 14 Dzapo, M.

HRID IIA Yes 15 Fiser, J.

HRID IIA Yes 16 Galmoff, T.

Master-Lee IIA Yes 17 Gardner, C.

Areva III Yes 18 Gomez, A.

Wave IIA Yes 19 Hufford, C.

Anatec IIA Yes 20 Humphrey, R.

Consumers III Yes 21 Ives, D.

E&I III Yes 22 Jang, K.

SAE-ON III Yes 23 Kang, M.

SAE-ON IIA Yes 24 Kim, H.

KPS IIA Yes 25 Kim, K.

KPS IIA Yes 26 Kirk, M.

Consumers III Yes 27 Kovalesky, T.

Areva IIA Yes 28 Lee, J.

KPS IIA Yes 29 Lee, Y.

SAE-ON IIA Yes 30 Martin, A.

Wiltec IIA Yes 31 Miljak, L.

HRID IIA Yes 32 Nadinic, B.

HRID III Yes 33 Oh, C.

KPS IIA Yes 34 Park, C.

SAE-ON III Yes 35 Popovich, R.

Westinghouse III Yes 36 Postruzin, Z.

HRID IIA Yes 37 Premich, S.

Wave IIA Yes 38 Schmitz, K.

NDE Tech III Yes 39 Shin, S.

KPS IIA Yes 40 Shin, W.

SAE-ON IIA Yes 41 Siegel, R.

NDE Tech III Yes 42 Skirpan, J.

Westinghouse III Yes 43 Smith, J.

Anatec IIA Yes 44 Stump, T.

Consumers III Yes 45 Yaklich, D.

Westinghouse III Yes Url-'lKl k.Ulellrles Appendix G *Ua-illed. Data/-Analyst Ineene W

rC:fJI~

I L

  • ,U/'

FIGURE A.1 Westinghouse Model D-5 Tube Support Plate Configuration

FIGURE A.1 Westinghouse Model D-5 Tube Support Plate Configuration AV2 AV3 AVIl

)AV4 11H

-.- i 11ic 43" 43" 10H T

T lOC 430

43 019H z-4z1-z 09C 08H 24 3

4 08C 4V

+

07H m~z zzz 07C IEH 05C 36

~

04C 03H 03C 28" 02C 01H D11C ISH 21.2 TSC TEH ITEC Anti-vibration Feedwater Inlet Nozzle Manway

Attachment B Inspection Scope / Results

Attachment B.1 As-tested Bobbin Inspection Maps

SG-A HOT LEG.610 AND.590 BOBBIN INSPECTION AS TESTED Braidwood A2R14 CDE D5 1

211 TESTED 11H-TEH WITH.610 1 228 TESTED 11C-TEH WITH.590 X 4048 TESTED TEC-TEH WI 6,1 a

83 PLUGGED TUBE

.10 105 100 95 90 85 80 75 70 65 SXXXX.XXXX!XXXX XXXx XXX X

XXX x x x:

xxxx:
xxxx.
xxxx:
xxxx
xx x x
xxxx:
Xxxxx Sx x xx
Xxxxx
xxx 1 XX
X X XX XXXx
xxxx 60 Ic 55 50 45 40 35 30 I XXXX xxxx xx XXXX X X XXX1X 1X XX XXx 25 20 15 10

.5 XXX XX XXq X X X XXXXXX XXX XXoX 45 40 35 25 20 15 MI:XX

X XX:XX X

_'Xx::

XXXX a

("

XX XXXXX'XXXX XX XXý TXXXX:XxXX XXX XXYX X3XXo:"XXX :XXXX: X XXX:T XXXX *XXX X ;X I X X XX X XX X X XXX :X XXX1 :XXXX I X XX

Xf Xa v

tv tvv,,

,r ',.,,'n A

', y 47 A t

~

2-t XoXXXXXXX: X XxxxXXxXXXXV XXXX Xc.

X X a

XXXXXXXx 4XX X:XXXX xxxXXXXX xXXx XX"T aX X XT XX X

ýX UXXX X:X X X::aX X XTX :XXXTX (X XXX X XX XXX X TX X X )(TX X X X XX :X X X 1XX X 0Xa XX X aX X X XX xxx xxcxx cxx Xxx YwX X

X xx. xx X X XXXX 4 xxxXX 4xx X Xx xX X

xxx xcc X

oXXX XX0X XXXX XXXX. XXX:XXX X 'X:XXXX IxX x X X X XX X X X XXXXXXXXXXXXXXXXXXXX XXX c

X xXxxxx cxxx c;X:XIXXX'Xxxx

)xxxx),YY xxxx',

x xxxx~ xxxxxxxxxxxc cXt,,XX:XX:xxx

,x;x;,xx, 4

XXx

XXXc XXXX: XXXX.XXXXx XXXX XXXXXXXxX X XXXX xxxx xxXx xXXXxxXXXX)xx

'.XxX:(Xx. xc XXXc cXXX XXXX XXXXXXXXXXXXX XXXX XXXX X X XXXX XXXXXXXX4 XXXXXXXX:cxxX x

XXXX XXXXcx Xg XXXX XXXX XXXX :XXXX:XX(XXXXX X XXX tXXXXXX X XXXX XXXX XXXX :XXXU;XXXX::XXXX X1XXMX

)

XXX X

1101 XXX X x )X X :X X:X X:X X;X X I XX I X X X" X X XX X X X I 431k X;(X I XX

ý XX

ý(X XXX xxxx.x.xx:

)::XXXX xxxxx xxx;xxxxxl xxxx xXXXX X x"xxx"XXXX4 XXXX xxxx:xxxxxxxxXXX,

... XXxXXXXXXXX XXXXX'XXXx:XXXX: XXXX. :Xx.

x X XXXx xxxxxxx:

xxxxxxxxx xxx' x

xx.

Sa axxxxxxXXX A

XXXXXXXXX a

XXXX: XXXX.XXXXXXXX Xx x

xxxx xXXX X

'XX;ýxxxx:XXXXýýXXXXý"XXXX:*XXXX:X X x xXX xxxx xxxx xxx:xxxx:xxxxx. xxxx XXXX XXXX lxx xxX XXXX ýXXX)(X XX

ý":XXXx:

XXX; XXXXX XXXXI:X X X X[X X X X X X.X X;X X :X X :X X

X X X X )X vv; xxx' XXXX~xxxx'

.xx.xxx.xx..xx x

x.

X x'xxx*

xxxxy.. x.xxxx...

xxxx xxxx 'xxxx x XX XxxXXXXX KX 4)ý XXitX 'I")"X XX X1XX X X

ý X

),

XX )()(4

XX:XXX X ý1X X XX X X X X X XXX X

IXXXX' XH)

X4 XXX CX X I XX X(`)(Xl-(

XX X X XXX XX XXT XXXXTXX X XX:X X XX:11X XX XX IIXXX:ýX TXXXXXI XX XXXX X

XXXXXXX:XXXXX

.XXXX X

XXXX XXXX

)X X I

XXxYXX

.xXXXXXXXXXXXxxx: xxxx xXXXXxxx

'xxxx x

XXXX XX:xxx:xxx XXXXxxxxx.

x XXXX1XXXXXXXXXXX XXXXXXXX XXXX XXXX XXXXIXXXX. Xxxx xxxx xxxxxxxxXXXX XX.

xX XXXX XXXXxx.xxxx

'XX;,xxXx xxxX xxxxxx XYYýxx'

XXX::XXXX IXXXX XXXX XXXXX XXXXYXXXX; XXXX:XXXX::XXXX
XXX X XXXX XXXX XXXXX XXXX XXXX XXXX :XXXX:XXXX:iXXXX XXXx X::XXXX::XXXX

~

~

~

~

~

~

~ ~

1)

)()(X )(X XXX X)(,

.X X

iXX'x X :X X :X X :X X

x XX-X-1 X

XXXXý XXXX `

X :.X X*XX

X X

X X 1x,1 Ix xxx xxxx x

xxx xxxx'x xxxxxxxxxxxxxxxxxx X

xxxxx X

x xxx x xxxx xxxx: x xx::

Xxx xxxXX X:XXXX;XXXX XXXX XXXX TXXXX XXXX;XXXX;:XXXXX;:,XXXX:X' XXXXXX 1:XXXX11XXXX XXXX A1XXXV XXXX XXX

,: XXXXXXU XmX,-XXXT XXXX XXXXXXXX' xxxx: xxxx xxxx, xxxx

,xxxx xx xxxx:xxxx.:xx

'xxxx xxxx XXXX XXXX Xxxx xxxxx::xxxx:Xxxx. xxxXXXX x:x:xxxxxxxxxxxxxxxxx xxxxxxxx xxxx' xxxx xX CxxXXX X Xxx xxxXXx.: XXXX" XXXX "XXx:xxxxx xxxv xxxx XXXXX xxxxxxx xxx-i. xxxx xxxx 'xxxýXXXX XXXXx.

x:(Xxxx' XXXxxx:xx xxx'xxxxxxxx xxxx:.xxxýx xxxx XXXXXXX X

xxxx xx4 xxxxxxxxxx xxxx.xx x

xxxxxx' Lxxxx xx xxxx Xxxxx 'xxxx'XXXx

."xxxx, xxx x

XXXX x(

'xxxX'IXXXxx XXXXXXXXxxXxXx:xXXxXX/xxxx

'xxxv*X xxxx.xxx xxx.xxx xxx 'xxxxxxxxxxx xxx'xxx xxx :xxxxxxx xxxx :xxx x' xxxx ;xxxx ~xxxx :xxxxxxxx ýxx xx; XXXX.XXXX:XXx x

XXxXx:

XX XxXXXXXXXXX XXXXx Xxxxxxx:x 'XXXXXX'XXXXxxxlx XXXX xxxxX.

XX:

xxxxxxxxxxxxxxxv x

x1XXXX xxxxx^xvxxxx xxxIx'xxxxxxxxx XXXXY Xxxxx.xxxx ýXXxxxx' xxxx"xxxx:xxxx. xxxx xxxx *xxXýxxxxxýx xxxv xxxx.xxxx. x XXX Y:XXXT:;XXXX :XXXXT XXX XXXXX XXXX XXXX; X XXXX XX XXXX:XXXxX

XXXX XXXX XXXXX XXXX XXXX XXXX::XXXX:;XXXX:XXXXX XXXXTIXX XX :xXx XXX*xxxxx xxxx xxxx 'xxxX]XXX XXXXXXXXXIXXXXIXXXXXXXXXXXXXXXXxx XXXXXXXXXXXXXXXXXXXXxxX XXXXXXXXfXX (XXX XXXX

'XXxX X;XTXXXX XXXX XXXXUXXXX XXXX13)XXXX'.XXXX :XXXXXXX 'XXXX XXXXX XXXX XXXXX XXXX XXXX:XXXX:XXxxXXXX XXXX XXXK"Xo xxx:..xxxx,-

xxxx..

xxx x..xxx:. xxxx xxxx XXX-xx, xxxx xxxxxxx,,

xxx xxxxxxxxxxxx"""

x X*xxxx

'xxxx:

ýxxxx xxxx.xxxx.xxxx:

XXXx Xxx:x xIx"xx xxx'xx xx xxxxxxxxx xxxxxxxx..ýXXX xxxx xxxx T xxxx xxxxxxxj"(xxxx'xxxxýXXýXX xx xx X xxx xxx 4xxx XXx x x XX x-es*"" 4-e4--: &-**

u-X**.see'".: 4-3444*"*14*4-.*-*'*14-*. **-W'-14*

~'"A', ee-ex*

see' 44-4-4444-X*x--X. +/- x;: 3 sexx--

xxx' ~

~

~

~

~

~

XXXXX xxxx xxxxXXXXXxxxxXX xIx xx

'xxxx xxx xxx 'xx x x. xxx xxx xxx xxx xxx xx xxx xx xxx I

x x xxx xxx xxx4 xxv xxx xxx xxxxxxx~xxx xxx. xxx xxx' xxx 3 xxx 4 x xx 1xxx xxx xxx xxx xx X Xx Axxxxx

)5ý-

X4

- 4 4 -

Xx e -4 Xx e e X4

~ 4 -

X-

~ 4 X,x

- -X i

Hx-x -

I I 1-

.1 xxxX17 XX.3 Xxx xxx xxx.xx xxxx xxxxxx xxx :xxx xxxx xxx XXx 4 xxx X

11 MX X X. xxxx xxx xxx xxx xxx xxx IX X X

ýX.

45 40 35 30 25 20 15 5

5 i10 105 100 I111 1111 till li1i 95 till tiil 1111 an 90 1111 mill 85 I iilliitiil:

11t 111 11i:

80 75 I 11 li 70 tlll i1111 liiii 65 I 11 111i 60

.iiiil 55 ii iiti11 1111111:

111111111ii 50 45

[llll 1111 1111 40 35 Ill 13 111 30

.i" tell 25 1.1111 11111 20 iii'i 15 10 vj'i'j'j 1111 1111 Iliti S

Westinghouse Electric Company LLC - ST Max 1012212009 20:14:56

SG-A COLD LEG.610 BOBBIN INSPECTION AS TESTED Braidwood A2R14 CDE D5 1 439 TESTED 11C -TEC WITH.610 a 83 PLUGGED TUBE 110 105 100 95 90 i

I I

I 85 80 75 70 65 60 00000000Q0000(P0000(0000(P0 55 1POO00 0

000.

00..

Do...

4....

i.....

1i'

.I.

0

'a a]

0o f 50 45 40

?OOOTOO000 oo~oooo 35 30 00001 7 000

,..*..aDOO 25 20 15 5

0, 45 40 35 45 25 00°..........

a a[

T....

I..........o

]

T I.....................

° 0..

0 a.........................::: ::::!::::

o...00 00 1

0 ooaa

.oo.

o.....................

0 0...

  • -O 0 -...

...... 0 0..

. 0 0...

0 0...0

00.

0

)00........

00*.

0 00...

.0 0.......

0 0

.0 0

0

0.

00 00

°,

~o

e..o 0()

O00......

00 o~a a...................

0...

0 0....

o 00.......................................0 0.a...................

I.......

l.... l........

........ l.... i.....0 0

0 0..................................................00............

......00...

0-00.....

o1 1 o o.................

. o*

.... o..

. o

00.

0 0

t.......

00.........

0o0 0

00 0 0 n

-° 0000 0000 00 00:0000.0000...

1 0........

o 0......

0 0...............................

... T..

I

      • 'I..

00 0.........

o i

0 o.1..... 1.

o::

°o

.:0 00.

. T......T 00I S.....0 0 oo o°

o.

0 0.......

ooo i

o o

l

. }*

. o

.............0 07

~ *.

0 0 oo...

1.......00

..............oo

.....o o o*.

T.......

00..I.

.T.

.I.

.o 35 30 25 20 15 10 5

15 11114.11111~11111.11111.iiii ii i l

Ii iiiii iliii iiii 111111111 11111 li1 4111.1 110' 105 100 95 loca1 11.11

9.

84 lll 90 85 11117511 1111 Ii11 ii111iiii1 80 75 I 1111 1111 70 I 1111 :.11111.1111 11114.1111411111 11114.1111411111 1111411114.11111 65 60 55 1111I 50 45 4.1111 11114111111111111 411114.1111 11114.1lal1111111 411114 11114.1lala'11laal1!1111 40 35 30 25 20 illll 15 liiii 10 Killl

~11111 5

Westinghouse Electic Company LLC -ST Max 10r22/2009 20:14:44

SG-B HOT LEG.610 AND.590 BOBBIN INSPECTION AS TESTED Braidwood A2R14 CDE D5 1

227 TESTED 11H -

TEH WITH.610 1

228 TESTED 11C -

TEH WITH.590 X 4066 TESTED TEC TEH JITH

.2 2 a

49 PLUGGED TUBE

.10 105 W00 95 90 13 oncc ccxx 85 cXXX xxxx:

x x Xx:

B0txxxx

!XXXX

~:xxxx X XX x 75X xX x

  • xxxx:

x x xX 4XX 70I xX X x x xX xxxx xxxx 65 X X X a x XXx

1. X xXx 60 Xx xxxX 55X X""xx X xxx x xX x X

504xxxx 4xxxx:

4xxxx X

45Xx x x

~ XX X IXXXX 40IxX Xx:

4xxxx:

4XX X x X.4 X

35I xxx xxxc xxxx XXX 30 Doo 25 20 15 5

X X

X

ýi cc ccxx 'XX:XXXX<

XXXXXXx'x X 1 X XXX XXXX X X XX XX XX X1X X X X XX

xxxT con ccX XXXX cxxx:XXXX X X xXXXX 4xxxx XX X XXAX X XcXcXXXX XX" XXXX :XXX: Xxxxx:xxxxxxxx XXXXX xa x;:XXxx::x:.XXXX:

XXXX xxxx; xxxxxl:X xxxx:: X xxxxx XXXX xxxxXXX 4

Xxx x

XXX 4xxXxxx' X

X X XXxxx xxx :,)xxxx xx xxxxxxxxxxxxý'XX'kXXI'XXX xYx." x ýx xxxx <<<I xxxx:Xxxxx. xxxx <<x x;yxxxix.xxxK XXX XXXX XXXX<XXXX<XXXXXX

<xx x

XXXX XXXXXXXXXXXXX:XXX XXXx x XXXx XXX XXXX XXXXxIXXXX XXXX:XXXX:XXXXIX X XXXX XXXX0 )XXX XXXXXX :XXXXXXXX: XXXX FXXXX XXXX XXYXX XXXXXXXX

.XXXX

XXX :XXXX XX X XXXX XXX gXXXX XXXX XIXXX
X XX X IX X

X XX XXXX XXXVX XXXX'LXXXXXX XXXXXXX XX X

XX X

(X X

XXXX:IXXX lXXXX* XXXX*:xXXXX:XXXX:XXXX

XXXXXXX XXXXXX XX'XXXXX; XXXX XXxxx XXXX:XXXXXXXX: X X

X XXXXXXXXXXXX:

<xx xXXXX XXXXXXXXXXXXXX XXxx XXX XXXXX XXXX XXXX XXXX*:XXXXX XXXX:XIXXXXIXXXX:Xx X,XXXXZ'XXXX XXXX XXXXXTXXXX

XXXXI:XXXXXIXXXX XXýXx J'XXX XXXXX XXXX XXXX XXXX]XXXXXX XXX)('XXXXXT:XXXX
X X *XXXXIXXXX MXXXX XXXX XXXXX:XXXX
XXXI:XXXX XX xXX XXX X X X
I XXXX XXXX."XXXX XXXXX XXXX
XIXXX::XXXXXXX X,XXXX XXXM XXXX XXXX XXXXX:XXXXI:XXXX:XXXX XX xXX
Xxxx

<xxx x xxxxxxxX Xxxxx:xxxx XXXX XXXXTXXYX:X X XXXX XXxXX xx XXXX XXXXx

<XXX

'XXXX:2XXXX XXXX xx:,xxxXX:XX

<ýý xxx:'xxxx xxxxýxXX XXXX XXXXXXXX

X X XXXX XXXX XXXX XXXX XXXx',XXXX'XXXXXXXXXXXX Xx xx

<xxx <xxx '<xxx

<xxx xxxxxx' xxxx

<XXXX XXXXý:XX)X'X:

X XXXX XXXX

<xx XXXX XXXX

xxxx'xx XXXXxx xx XXX.XXXX XXxxxxxxIXXX X

xxxx4 <x XX x. 'xxxx::XXx: Ix X XXXX.XXXX xxxx XXXXXXX)

XXXXX xxxxxxXXX XXXX XX xxx.'*XXXXX xxxx

<(xxx xxx, Ix<<<<xxx'xx xxxx.x..

<xXX x

xx*

.*I

'XXX X

XXXX XXXXXXXXX xxxx xxxx XXxx xXXX.4 xxxx xxxx; 1<

XXX xxx' xxXX XXx xxxx:Ixxxx'fxxxxxxxXX xX<

IXXXX XXXX"XXXX XXXXXXXXý;.XXXX pcXXX<

XXXX'

'ýXXXX'"XXXXXxx XXXx XXXX: xxxx' xxxX'. xxxx..xxX: xXXXX XXXX XXXX' x-Xx.

' -X 1:*XXX

+*

X XX-X-

'X#'

e -

-'i;;.'*. X XT X

T Y)

X-X.X XXXX'XXXXXXXX-*XX IX-XXXX-* XXXX H

  • i e
XXXX::XXXX~

~~

XXX IXX XX XXX "X

XXX:X X'X X :X X

,X XX XXX X X X XXX X

XXX:X X :,X X xxX X

x:XXXX. <XXXXxxx':xxxx :Xxxx x

xxxx xxxxx:

xxx;X.

xx XXxx:4xxxx:x:XXxIxXX XXXX XXXX XXXXx:xXXX X XXX X XX XX XX X X: XXXX IX)XXX::XXXX

'TXXXX, XX IX X X X XX XXX X XXXXX XXXX XXXX',XXXXX XXXX XXXX

[XXXXX XXXX XXXXXXXXX XI X XX X XX XX T X X XX X X X IA X; X XXX
XX XX X IXX X :X1,X XX XXXXX XXXXX XXXX XXXX XXX IXX X X X X X X XX: X XX X X X X :XX X X XX XX TX X XX XXX X XX AX X X XX X X X X X X X XX X X XXXX*XIXXX
XXXX:IXXXX {XXX X X XX X X XX YX X

ýXX XX S X X :X X :X X ;

X

, [

X, X X X X XXXX XXXXX XXXX

X XXX X XXxX

`XXX X X X XX XXXX"IXXXXXXXXX '<,XXXX X X

Xxx9xxxx xxxx xxx*xxxx;"XXXX<XXX xxxýxxxx XXXX XXXXXXXXXXXXx

<XXXXX'XXXXXXXXXX XXX XXXX: X:XX

X'XXX."X XX>; '.

X'

  • ,X 4X X X "X/

XT X XX X:"

TXXXXX X X X X

X X:

XXXXX

'X:.-

X XS

.44X X XX X " X

,X X

X X XX X

XXXX't XX:: XXX ;,XYX xxx*

XXx: XXX X X

'XXXYXX'XX XX X Y X XXXxxxxX XXXXxxx xxxx.X X X'X XXXXXXXXXXXXX X X X' xX X

xX X

<xX XX. X X X )(1XX XX; XXXX:XXXX X XXXXXXI X XXXXXXXXX XXX X XXXYX XXXX:1X XXXTXXXXT'XXXX:XXXX

  • XxX XXXXX XX X X::X X X.XX X),X XX.X X XX X

XXX.

XXXx xx xx

<xxx :xxxx: xxx xxxXXX XXXX XXXX.XXXX<XXX'XXX

XXXX4'XXXX XXXX XXX' xxxxXXXX XXXX Xxxxx xx:

.XXXXX

.XX X X X' X*

  • 'XX X

':X :.X Xeie'*XX X X'XX X XX-X X X X X X X X X X < X X X X-X X X X1 X X X X-X X X X :X X X X X X. X X X X X X X X X X X-X'X"X X X-,

"I"-X X TX XsX-X X<X X xxx'<xx <xx 'xxx xxxxx

<xx 4 xxx xxx xxx:'xxx x xxxx xxx <xx xxxxxxx xx <xx 'xxx'xxx..

x x xx xxx.xxx '<xx xxxxxxx'<xx xxx~xxxx x X x XX <x.<<'xx4<x xx<x xxxx.xx xxxxjxx x

110 1111.111111 110 105 100 95 I 1111 1111 1111 1111 90 I111 1111 1111 1111 85 L 1111 L1ll 21111 ill':

liii]

lulli ilil:

111<

liii:

1111:

liii:

1111:

11111 liii:

1111.

1111.

1111.

1111.

.1111.

.1111.

1111.

1111.

jyjiIj

.1111i1111

.111111111

.1l11~1111

.1111

.1111

.1111

.1111 LII~

iiii1 iiii1 1111:

1111.

iiii:

1111:

.iiii:

1111:

liii:

titi:

1111 1111.

1111~

1111.

.1111

.1111

.1111

.1111 L I1I 11 ll1114 iiii11

.111i2 1111 1111 1111 1111 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electric Company LLC - ST Max 10/2212009 20:22:58

SG-B COLD LEG.610 BOBBIN INSPECTION AS TESTED Braidwood A2R14 CDE D5 1 455 TESTED 11C -

TEC WITH

.610 a 49 PLUGGED TUBE 110 105 100 95 90 85 80 75 70 65

[a..

a 0131 al-.

60 0

0 0

0 0,

0.

O, 55 50 45 40 cDO~OOOOqOOOOOOOOQOOo 35 30

.OOO.

1

  • *aa 25 15 10 5

t 00001 0 103 13 45 40 35 25 20 15 a.....

a o

0......

0 0

0..........................................

.... 0 0......

Do 00

0.

00)0..

0 C

0 0 00:

  • .0 T o o 00..........

0 0....

00........

00 o

o...O()OO o C)....

0 0.....

1)0.......0 00..

__"__i 00.................

0.

0 0

00 0....

0 I

oo...

0 T....

°°°........o......T.OO...............

v: 1.

0

.i:: :..

....T...T.°° 0

0 00 00

.0....

.00 I

0 0 o0..

0 0000 0.. 0 0.

I.........00 0 )

(00 0 ) 0 0 0-..

o0..

o4,::

`: : 0:

0.:

0.

000... 0 f.... T...............°'......................

TI.....

° 0 U 0

.T..

(

0

.... '........ i.........

i...........

.1 T

0..............

... ° °....

oo 0

....1 oo........

o,00 : :.

T.

o

  • .-.t

~

~

~ ~ 00

.......... I l o oo,o oo o o oo o o o ::: :: :: : :: ::

0 0............

.... T....

I.

I 0

0::::....

. 0 0:

o

.. iO C

00 0

o0.

T..

.T..

0 00.

T.

00:::

o...

T

. T....

0.

45 40 35 30 25 15 5

5 1111 liii liii liii

.1111:

.1111:

.1111:

.1111:

liiiI:

1111:

11114 l11111.1111..iiii1iIII

.111111111 11111.1111

.iiii

.1111

.1II1 illI

.1111 LIIII1

.1111 iii liii:

Alit:

.1111:

.1111:

liiii Iiii:

liiiiiiiii.

lilllill.l ittttt

  • 1111:

iiiii.

1111.:

.1111.:

.Iiii

.1111

.iiii 01111 1111211

  • i~~i1 4111111 111111111 30 25 20 iii:

iii:

iii:

liiii:

11i11:

iiii.

iltli 1111 liiii

.11111

'illl 11114i1 i1i. iIi 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 15 10 5

Westinghouse Elecdnc Company LLC - ST Max 10/2212009 20:22,46

SG-C HOT LEG.610 AND.590 BIBBIN INSPECTION AS TESTED Braidwood A2R14 CDE D5 1

228 TESTED 11H TEH WITH.610 1

227 TESTED 11C -

TEH WITH.590 X 4050 TSTNED TEC TEH WITH 6:1.0 a

65 PLUGGED TUBE 110 105 100 95 90 x

ax',K xxxx 85 xxxx Txxxx Xxxxx xxx~x 80xxxx xxxx Xxxx Xxxxx 75 11ýI X X X

'Tx x XxxX XXX 70xx X txxx

1xxx 4PUSX 65 lxx x:

X, 4xx:

60 tx 55 x x x x x X :fxxx a x xx x c

3X Xc.

50Y Xxxxý x xxxxx fxxxx 45 x xc I x x X 40x xt x xxx xx x x 35 Xxxx x xxxx x xxxX x xxxx 30 X

XXc XXc1 25 20 15 10 X :XXXX:[XXXX XXX X

X X"X X

  • 3
ýXXXX*XXXXY'.:X X[X X'X X

X X xx xxx.xxxx Yxxx %`

jxxx xxc xx a

c; Ixxx xxx xxxx~XXXX x x Kxxx:

xx XXX xxxx X ax XX Xxx x XXx Xx XX XX.XX a x'

XXXXXXXXXXX XXXXXX' xxxx xxxx:xxx XmXx:X~XXXx XXXX X.XXXXXXXX; XXXX XXXXX*

a "KXXXX;:XXXXXX'XX" X',X.KKK,:KXXXX

'XXXX

XXX, XXX
XXXX.X XXXX X

XXXx t

xx xxxx

'xoxx Xc a'xxx'xxXXXXX Xxxxx:xxxxxxxxXXX.:xxxx

ýYxx:

x X MXX:

X X :XXXX.

'"..XXX X

X" x X, x, 11,

.""v",,,;

    • v

,.¢ X :X X :X X ;'"X.

x..

XXX I XXXTXXXXXXXX

'XXXXXXX XXXXXXX xxxx xxcx X

x XXXX;sxxxXXxxxx::XXXXXXXXX XXxXX:xxxx xxxx:xXXXX:x xx xxxxXXX x

xxxx 'X"'XXXX x

x xxxx xxxxUXXXx::XX"Xx.XxXX XXXX xxxx"xxmx xxxx xxx

XXXX xxxX XXXX xxx xxxx X XXXXXXXX:X XXXX xx xxx XXX XXXX
Xxxx'XXXXXXXXXXXXXXXXxx XXXX XXXXXXXxx x

XXXXX XXX xxxx xxxxx xxxx xxx xxx XoX",

.xxxx.xx x

.{xx

..xx x.xx x x Xxx xxx xxx xxx xxx xxxx'xx.

xx xxxx "xx x

XXXx xXXX XXXXXx 'x XXXXcxx'xxxx x

X XXXXXXXXXX.

xxxx XXX *XXXXXXXX.

XXXX XXXXx x XXXXXXXXXXXXXXXxxX xX XXXXxxxxxxxxxxx X-XXXX,xxxx

'xx xx xxxxx.xxxx' X XXXX XXXX XX xx:x Ac XXXXXXXXXXXXXXXxXXXXXX XXxx I xxxxTXXx xxxxx x X x

xxxxf X

xxx x XX x

Xxx X xx xxx x xxxX X

XX XX X

.XXXXXXXXXXXXX XXX:XXXXXX xx xxxx"xxxx.xxxx x

x.:xxxx xxxx xxx x xxxx 'xx xxx x

xxxxxxxxxxx'xXxxx

'4Xxxxxxxxxl'xxx xxxx xxxx.xxxx xxxx:Xxxxx xxxx x x xxxxXX X xx xx Xxxx.

xXXXX XXXXXXXXXX.

xx;'

XXXX XXXXXXXXXxXXXXxx xxx

xxxx x

xx x

xXXXXXXXX x

xxxx x

XXx X X XXXXXXXXXX XXXX'XXXX XXXx xxxx XXXX XXXXX x x xx XXXXrXX xxx x xxxxlxxxx' xx X

x X xx XXXX.XXXXX.X x

XXXX::xxxx:.xxxx xxxxx xxx xxxx.xxxX XXXX, XXX MXc xx x XxxX:xxx. xxxx xxxx xxXx. XXXX XXXXX

.xxxx x XX:

xXXXXxXXXXXXX xxx:xx XXXX:x xxxx xxxx xxxXXXXX X xx xxxx...

w)

'x'xxA' v"x"' v""xv" X'"'

XXX

.XX XXXX'XX Xxxx XXXX xxxx xxxx xxxx xxxx; xxxx.xxxx. xxx xx xxx xxxxt xxx*X xxxx

' xxx:

X XXXX'xxXX:XXXXX.XXXX xxxx xxxx xxXX xxxx

xxxxxxx.XXXX XXXXXXXx XXXXXXXXXXXXxxx XXXXXXX xxxx XXxx x,.-.,Xx xX XXx XXXx:xxxxxxxxxxxx I xxxx 1.XXIX xxxxxXX;ýXXXX}<XXXX' XXxx. :xxxx XXXX'XXXX XXXXX xxxx XXXX XXXX xxxx XXXX xxx xxxx xxxXXXXXxxxx xxxxx xxxxxxxx xXXXX'XXxxxxx xxxxxx XXXXX xxxx xxxx. xxxx' xxxx:;xxxx xxxx xx xxxx"xXXIA XXXXXXXX

',:xxxxxxxxlxxxx xxX XXXX: XXX X1 XXXX;XXXX XX.XXX x~~~~~~~~~~~~~~~

xxx xxxxx'xx.xx.xxxxxxx.xxx xxx xxx 'xxxxxx xxx Y X Xxx"I x xxx xxx X x Xxx)xxX I)'xxxxll X xxx xxxx:'XxxX xxxx Ixx.x x.

(Xxxx xxxx xxxxx xxxX..XXxx:lXXXXX:xxxxxxxxxcXXX cxxx'x xXXX xxxx ;Xx

'4 Xxxx::xx XXXX

'x x

XXXXXXXXXXXXXXXXXxxx xxxx xxxxxxxxxxxxxxxxxxxx xxxxxxxx xxxxxxxxx xxxxxxxxxxx:xxxx 4

XXX'ýc

',xxxx xxxx x

-~~*::

~**~.
  • 42*

~~

"~s".

4"'~*

  • ea

~::;1*

Xm*

XXH225.-2.':. s*(&-,

-*X XX xx :xxxx.

xxxx:xxxxxxx x xxx x xxxxxxx xxxx.

xxxx.xxx x.xxxxyxxx XX XXX xxxxxxxx:

xxxx" xxxx xxxixxxxx;xXXX:

XXXx xx XTx x XXx x x('xxx xxxxx

  • Xxx' xxx x xxxxx xxxx xx'x x

xxxxxxxx xxxx xxxx:[xxxx '.Xxxx xxxx: xxxx':xxxx: xxx x xxx xxx xxxxx x

xx xxxx' xxxxXxý xxxxx xxxx'

)xx 7iX x

x Mx xxxx xx x xx*x x

.x X x X Xxx:

xxxx X)(

iXXXX xXXX:

xxx XX x Tx x x X X X X' X x

.-XXXXXX M

XXXX XXXX

,X ;;X XXXXXX XX

,*X x.:X T

x X x T X X X:'."

XXX

ý,

Xx X:**4<:

X X

(:X X,X X XXx xxxxxx xxxx xxxx xxxx XXXXXXXXX XXXXXxxxx xxxx xxxx' xXXXX:XXXxXXXXX'xxxx

'xxxx XxxxxýXxxxxx: XXxx xxxXX XXX xxx.Xxxx xxxx xxxx XXXX'

'XXX XXXXXX.X xXXX XXXXx XXXXI xxxxx
xxxxý"X XXxxx:xxxx*xxxxx xxxx;XXXXI

.XxxxXXXXXX XXX XXX Xxx X X

xxxxýxxxxXXXX xxxxxxX Xxxx XxxXXXXXX Xxxxxxxx:Xxxx xxx XXXX XXXXXXX.XXXX;cN XXXx xxx xxxXXX xxx 'xxxxx

XXýxxxx xx IX x xx xx' Xxxxx xxxx"X x xx x x xxTx xx xx xxx T xxx' xx xx: xxxx '(x xfx x x x xx.:xxIx x i/X x x x Kx xx xx xxxx Xxx xxxx :XXýxxxx'xxxx 'xxxx xxxx.:xxxx. xxx':xxxx xxxx.xxxx. xxxx' xxxx 'xxxx Xxx x)XA, xxx xxxxxxx x xxx AAxXx xx xxxx XXXX'XXXX-.Xxxe*' '*-XXXX XXXXe XXX XXXX x*x*

XXXX xx'xx-x-*

"x***

'-x-XXXX XXXX

  • -*-x'ix-x--

-x-x x-x-x4xxx X)*vx~ ~~~~~

.X..

IXI

)IX X

"X XX..,

.v,,,

v r

VX "y"

Y V

{

fy 45 40 35 30 25 15 10 5

1111:

1111:

1111:

11112 liii:

1111:

1111:

1111:

1111.

.1111.

.1111 1111:

.1111

.1111

.1111 4111.

.1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111 31111

.1111

.1111 LililJ L1111:

11111 1111:

11112 11111 1111:

1111.

1111:

1111:

liii:

1111:

liii:

iiii:

liii:

.1111:

.1111.

1111.

.1111.

.1111.

.1111.

.1111.

.1111

.1111

.1111.

.1111.

.1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111 L1111 1111:

1111~

liii:

Ill

liii:

.1111:

.1111:

1111.

1111.

.1111

.1111 1111.

.1111

.1111

.1111

.1111

.11132

.11112

.11112

.1111:

1111 1111 1111 1111 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electdc Company LLC -ST Max 10/2212009 20:26:10

SG-C COLD LEG.610 BOBBIN INSPECTION AS TESTED Braidwood A2R14 CDE D5 1 455 TESTED 11C -

TEC WITH.610 a

65 PLUGGED TUBE 110 105 100 95 90 85 80 75

( ' OOO0O00OT0000 0.........

70 65 60 (PO00()O[]OO)Oc 55 50

)0000Q0000 0

a 0 4.-.

45 40 OOMOTOOOO 35 30 25 20 00O001

...O(DO 15 10 5

m0o....o 00..

J:::. 1::::: ::--;'-0 :~;: :;~

45 40 35 45 25 20 15 00...

1..................

oo.

T 0

00 T......................

00..

.T..

.T.

om -...

a

.. 0 o0.............

.......,0o0 a......7:

.. j 00 0 0.

.. 1....

0, a.....

0..

.a 0................oo

.... 1

.... T....

]......000.o.............0 0........

000o

.° o

o..

m.

D 0......0....................0oo 0,..........00.............0o 0........

o o.........o................-.o..T.°..

00..

0 0a.

0 0.

0 0."

°°.

0............000...................

0.0. 0 13......

I 0........o......

.0 0

0 00 0

00

~...

T........

0 I ::

I*;**

I1/2 L

0.......................

.0 0

0.....

.0....0....

I....

1. 0 E) 4

°°°°-°°°°.°°°°*°

°..

_"° 0..

. 0 0

0000 0000 000

0.

0 0

......T....

T...................

T......T.

I........

0 0

.0000I000 0

I T

00 I

0000 0

o o-

~

0 0

0:::..:

oo 01 0

0o...

o o00..........

....v :

0 I.

00.........................0 1...."..............

I....

0 0....

0............TI*

i:

35 25 15 5

5

L1111111.1111 11114111141111 1111111111111 1

110 105 100 95 90 85 80 75 70 I1i:

iii:

iii:

liii:

1111:

1111:

liii:

1111.

1111~

1111 1111.

1111.

.1111.

.1111.

.1111.

.1111

.1111

.1111~

.1111

.1111

.1111

.1111

.1111

.1111

~1111 All 1

.1111

-1111J 1111~

1111:

1111~

111 111 iiii Iiii; 111141111: 1111

.1111 1111 1111

~1111 1111

.1111 1111 L111 Lilli 111111111.

111111111.

65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electri Company LLC - ST Max 10/22/2009 20:25:57

SG-D HOT LEG.610 AND.590 BOBBIN INSPECTION AS TESTED Braidwood A2R14 CDE D5 1

227 TESTED 11H -

TEH WITH.610 1 228 TESTED 1IC -

TEH WITH.590 n 4089 TESTED TEC a

26 PLUGGED TUBE T

I T W. I 1i 0

.10 105 100 95 90 Pi n A fnnn 85

.1.,.

80 I nn 75Atn fin.

1-1.1 11r' wnn nnnnffl 70 1infrinn rin (,. A

'Tofn nnp

]innnn.

65 11 dnnnn 60

.55 50 T1 nmnn innnn 45 pnnnn'

~n nnn Iin l

40 jT nn nn nonnn

~nnnn 35 tbnnnn tnnnn 30 25 20 15 10 5

n 45 35 30 25 rlflnnntftfn t

n n r.fn n (t nnnn ntf ý n nýi r.n n i rl fim n m n n n n mn n mn n n n m nif ft n, n n nff A

'n rn

'"n n f in rnir ir (1 (In.

1 fnrlprinnmi-frinninnf-n""

innnin flvt r

t'-

nnfl-f-fnrt nnnn "n

nl "n,

nnn n

n inn m n nnnnflnl n

I)nr flrflcfl ýt,-n'tlft itllii~fff llttfiii f

t n.nn..nn mnmnnn n 'nni imnnmnnn..

mft v

nmnnnhnnnn nnivvt r r

Kn nrmii nnn.

mnnmnnn n rttnm.nnt mpnnmnnn n n (frinnnr nfirinninn f

"r ffn i"

fi flfnnnmfnnnnt n mnn mnnmnntn""nnnfnmnftft

(

n't't't"

t fintflflfifi n

fýý!)i fnn,.

f if)(4, nnnn nnnnnmnnnn nnnmnn rlrrllttf'-

t

-nl f

nmn mnnmnnntnnff-if.

""fnnnmnnnrriiq,)r minin,,,

nfi n fnnn nt'nn n t riff 11 fii" ntn n

innn nnnn f n

f n(i nf-nn, f F1tii(

( lr I n

-nri if!ri ! -

m nn In nn In nn ii nA i n mm n

mn n nn

ýfisn n innr M f) lf) fin C

4 iý i'ý f t'n1- "f-nnnnfi n

n i f ifi i ni'"f-ý.n fi nrir tn t f,

fl nn nmnnfll ilfffinftntnfnnnnftftftll 4'

nnmnnnfrt nnnml nmnt'*t I'

f flflflnnn nnnt nnnfftfl t'i Cý^,

onnnmnnnnmnnn'i"nnnnmn nnmnnnnfirttnllnm Iliff fifl.Im""f inn If~ljlIfffff finfl l"""" flfififll

~

~

~

~

~

~

r Alf~fffiitill.~ffff fiff.f fif 4"'V rl f

inn r

infinnnntinfl,f nr""

aifri f'ff t t

'lllin ii ntt f-vnit fifinnnimnit fifttttimfftlff-tfftinriftnni nnf-lf--ftllfft' f) n n n~

"fltll tnn fit f ntfi n

flfllflt infnn finnfrift nftlif innn ru n ntlffnn nnnfrfntfnf Innt nn obir i, '.,,,,,, ft...

,nnimnt,,

mnnn tinnnnfnnnnlmnn mnnmnmnn n

nnnnnfifinntlf nmnnnflfmn""nnfintfifnn f

n m

nqq"""innfiný.jtaý'".c ifiiit ft,,,

,ft""}ftfl~innni

.nýictrifl1{'ir~rnrfif-itýf-ýif i rntf-ýiiýifmfmfttltmnrtft nmnnnnmnnn mnnnmnnnnivtvt-'

nmn n nnnnnmnnnnfi,

,,,,, i

"""mnnn ffff fttf 1"

ifil ft

(ýý In mnnn n, n nan ii flflflllft nn nmn nnmnnnm nn in f

nn n nfl nft-vtn flnftiin t

nnif nmnnrtr ot

""f, linflt,"f) l_

ifi,,,,

fir ot ipnnfn r

nn mn ifl,,,,t ftiffifi ftflflmn nn nnnýn lP nnnfllntfmiiiftit tfllaa.ý-flfK nnn" "ifflnfln ftfi, fifi f ft ftft nnn mn nit,

C 'flflfl'"t"

,nonn

,nm n

Ififinfif~~~~~~~..

nfifftiltlf~fffltftn ninl

'(

lfftftntl '>

iit n"""Cinnnnit'V"

fit'tf n nqinn fin

-nnq i n f-f.

nfl!fl! r!

l I!- nf n-f-Ffl-il fl-Ai't- {

1-fl-A-ir~monn--tnn---

nn-44. f-nA-nn-nnnnn-ltt nnn-nntnnfill n4 iinfrinnitff-I nnflntI.f nnnnnmnnnnn mnnnnmtfffll~ffft nnn,,finnnf P~,1r

"""fin fiiinnni 4t "inninbrn w

A'tp.fiPn 45 35 30 25 15 15 5

5 tilt:

liiii.

Iiii; liii

.1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111

-iii'.

.1111

- 1111

[.1111 L 1111

[ 1111 liii till:

1111:

ilil:

liii:

liii iiii:

liii:

liii:

till:

1111.

itti:

.1111.

.1111.

.1111.

.11

.1

. 11

.1

.1

.1

.1 ii11 Ii11 ii11

.111 Iiii1 iiii1

.11i1

-iiii Liii IiII:

tiiii 1ilt l1lt 1

1t liii:

till:

liii:

liii.

liii 1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111

.1111 Iiii liiII liili i10 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electric Comipany LLC - ST Max 10/2212009 20:28:"

SG-D COLD LEG.610 BOBBIN INSPECTION AS TESTED Braidwood A2R14 CDE D5 1 455 TESTED 11C -

TEC WITH.610 a 26 PLUGGED TUBE 110 105 100 95 90 0

000 0o..

85 80 75 t000O9000090000

)°' "

.. i.

0.

.T..

.T.

÷... T... ::...

70 65 60 T OOOO(IOOOO(90 0

55 50 45 40 0oooo09oooo0oooo0oooo 0 f...

35 30 0000

  • ooOO 25 20 15 10 5

1-3 0,

0, 45 40 35 25 20 15 oo.....

.......... 0 0.........

0 00..

0............

o.

.0 T.... T 0

0oo.... i

.1.......

7**

o (0.....................

0...

° 0

o

00.

.a..

0

-00

.o0 v::: ::i,_

  • 0.

.0 0000..

0 1T.

0.....

000

o.

T S.....

0oo -

.0.......

0 o

................. l..

..o 0 o....

0 )...........

T (D

o :: : o 0.

.I.

T.........

.... T....

00.

° 0.

I..

..... I e...

....I..

o o...:.

.... 000 00 0 0000.....

o T-o -,

oo.°.

o° 00

.... i"°...

t 0

0°°

°..°°,..00~oo

01)0::

0..

..(DO' t

.... I....

I '

0..

T.

0...

. T.

: ::0: :i

........i......... -

0... t.....

.......0

.*:. *.o 00

  • ')'.0 00 0.*-

0

÷o oT 0

o...

0.

...... o..

..l.......÷ mo

.... T.......

T

.1.

o oo..

~

~

~

0(....

0..

"000::[::

T T

35 25 20 15 10 5

45 5

iiii iiii 1111.

iiii1

.iiii

.iiii

.iiii

.11ii

.111l iiii1

.iiii I1iii 11111 iiiii lii~i:

1i111:

  • 11112
  • 1111:

111ii 1111.

ii11:

11i1:

iiii.

iiii.

1i11:

1111.:

1111.:

.1111:.1111

.111111 Iiiii iiiii i1iii iiiii Ll111

.1111

.1111

.1111

.11111 liiii liiii Iiii:

liiii; iiii:

.1111.

1111:

ii1i:

1111.

.1111 1iii1 1111i

.111l

.1111

.1111

.1111

.1111 1111

.1111 ii11111111:

[1111

.1111l.1111 110 105 100 95 90 85 8

75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electric Company LLC - ST Max 10/2212009 20:28:35

Attachment B.3 As-tested +PointTM Special Interest Inspection Maps

SG-A HOT LEG TOP OF TUBESHEET PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 S 1748 Tested TSH -18 Through TSH +

4 Inches a

83 PLUGGED TUBE 110 105 100 95 85 80 75 70 65 60 0000SSSSOYSSOOTOSSOTO0SS 0 00s:

00*s

.0ooo 1SSS. ss. -ss.

sS.S SS.

SS.

sss. ss. *

.55 SS ss0 S

S S

S 55 50 45 40 JS-SSqs* 0 SSSO SS..*OSSO

.SSS.

  • ss....

35 30 00SSI I'

ssOO~

SS 00 25 20 15 10 5

  • .SS 45 35 30 25
  • s.

IS s. = o...

..s s a

- - S-l

-S.

. -; :.S o °-S

-e

SS~S.SS.

s S 003 oSS,.. as a..-

SSSo SS.....SS SS 0 1

..S.

S.00 oOSS

... S SSS oS...

.-SS..

SS 0 S

-S

  • SS" S

SS

' S :;'

0 a.SS a....

S.S.

Ms SS

  • -S S

.0..

S.

.S So S

S.

01...S 5.....

-SS SS.0 SS So SS

s.

S SO.V S S s.5

...5

.**S SS.......SS 0 5

SSS. SS**.5-

  • SS-as S 003 S

SS0 osss.

.ss.o

.5*s...ss g...

S

..5....sso S 5..05

  • .S

..5...

SS:S 1 s......5 0

S S.SS.

ss.., *S.

s..

S *1

°.

SST,...S... S SS

0. -SS...

SS 0 S

SSS-S

.*S 0

o,.SS s

  • ...sS...

____ o o

1ss s,

ss

.:.~.::S Ss

. o,, o...s

...SS

. S SO,.SS.

S S.

$SSS SS.

. SSO

.SSS o

S 0

0 SS.

, SS-SS-

.SS SSS ss sss ss

.s..

s

s.

0.s Ssss S,

S

.S S.

S SS 0.S 0 SSS SS SS SS.S S

sI

.{:

.s S....

ss*. 1..

SS

S

._.SS...S...

S.

S ssssooo 0*S..S - -S SS SS SS 0 S..v

. S° S SS o

. s.

s s*

. s :s ss.

ss o

  • s sss..ss.,
  • ...ss

..-s....

ss j

ossS..T.

ss s

isss

.ss..

.... ss o s

SSs s0,SS.

ss5.

s.

.ssss

  • o

.SS.

.. SSSSSS.,Ss-.

S SS

.- -S S

7 S SSSSI Ss oSSSS s

.. sso s

s...

sss

.s

.. sS s

o -.

jS.S---.,.

S ass@.

o.

o

.SS.

.. SS,-.

S o

SSS.

SS--tboSSo oS ooooo 0 0');SSO(,SS..

SS SS o..

S: -S.S S.

S S SS SS O --

S: 0 SS... :

S SS: S.....

..SS 0

S S

  • SS:

SO O

S.. -

SSS.÷.SSO So-S SooT.SS.

t S*o

.S-

  • . ss.ss

.ss.

SS;

  • SS ss..,ossomooss6ooos oooo>SSSO()ss.,

ss.

S:

{.s;.

... s.

TS S SS. soO, S )

s

-° - --° °S ---°... -- s S -

-S S

s ;...

ss.

- S.

~ s

.. ss, s:...

  • s-s s s. t s --....

s...

sss 'ss.

s

. s s;..

. s s ÷ s.,

S S... ISS..

SS.t..ss s.

... *S s ss

- SS-I. s..

1 sss.I SS. -s...s *. s...

S..,

SS~ ts *.S-S :1 ss

~

ss..

... ss....

S s:;

s SS s.

s - -

os*

T sss.

ss.

.. s....

ý s,

  • s s ssss.

ss.

ss.*.si :s

.... s

. s..

  • s s +. s

.ooSS S.

ss.

.Ss, o... *S.. s s o oss:;s

~;S

.SS.

S o

.... *SS.S

...........o...

s. s.
s..,, o : : * : s o o s s

oss*s

.. i i ss....SS o s...

.¢.

S.

S: i- -

o ss. s~

s

. s, oS:: :: o: : ssss --

S.*S~i o S S s...

s.

s.

s s..

s

s s. -,........., --.s

--S.

-S...S...

.s s

.s s s~

s

.s s s 35 45 15 10 5

15 10 5

0-SS 0-SS

o. SS 00ss

'S.

SSSI 1 S5.

5 80s s s s.

85 80 75 S

.0S

...ssss.

s..*ss 000 0 45sso 4aoso0 sso 55 50 45 40

.ss.;;1.

.s S

.s...

.SS....5 0 OSS1oooo 35 30 0000 25 Ss....

ssss ssss

ýs ISSS--ss SSSS

$S..

SS s.SSSS

$S000 soss;sol9ss~s 20 15 10 5

$Sooo4pSSo0t0oSSo¢PoSS(PoooS 110 105 100 95 90

)0000(p000 70 65 60 Westinghouse Eleceic Company LLC - ST Max 10/2212009 20:15:01

SG-A HOT LEG LOW ROW U-BEND PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 X 68 Tested I1H Through 11C a 83 PLUGGED TUBE 110 105 100 95 90 85 80 75 70 65 60 IOOOO @Oo0OO OOOOO,OOOOq'OOOO OO 55 50 45 40 q)o0 0P0000 PqOOOOq(oO0O0 0..-.

o000o1

,,e,*oe~0 35 30 0000::°ooo

9.

o00 0O....loo O

25 20 15 10 5

45 40 35 25 20 15 00..

0........

0a 0

00

()a.

1.*

... T....

0 o........0..................

  • .... o o..... T........0.

..... ::i

.... 00o 0

0 0................

.o.

o 0

, o

*;

o

.0oo.

Q °.......

0 0..... -.

0.

.00 0 0 oo

n.

(0 0.....

oo0o 0

o_

0 00.......

o o.....

.::o

° O0..

00........

0 0

.I__

o.......

.. oo..........

oo 00............................................

00...

0 0

oo.......................................*.~.......

  • .... o o...............................

o.....

o...

.. o 00 0

0 0 0 0 0 0.

0.

o o0 0000000000....

0 o.0 o

.... T....

o 0

.o ::::

0..................................................

I..

°

......... T....

.. o 0

00

........I..

0.
p.

0 o

0000 Q000.

0:.

0

......0

..0 0 : -

0 0 0 i

. I.

o*

.....1....)

0 0

1

0.

I T.........

T........

T.............I0 0

00..

.................I o..

°......----

,o -- ---.

. i ;..

., oo,.

... : : : : t i i : : i ; i i :

45 40 35 20 15 10 5

5 00:

X XX.X Xx..

X.X XX.a Sx.......

85 80 75

  • .xx.....

... x:.x.x*...

x X...

40 X

0X 35 30 I

I I

I 2*5.

0 x 1o X X 25 20 15 le 5

XXXX XXXoXXXOhxxoo)ooox,',0o 110 105 100 95 90 pooxx(p*OOOOOOOx o00ooxx0oo0 0ooo0 70 65 60 55 50 45 Westinghouse Electrc Company LLC -ST Max 10/2212009 20:14:58

SG-A COLD LEG EXPANDED BAFFLE/CORNER PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 2 16 TESTED 02C +/-3" a 83 PLUGGED TUBE 10 105 100 95 90 85 80 75 70 65 60 55 50 45 I

1 1

1 12OOOOOOOOOOOO OO(OOOOPO(9O OqOOOOOOOO`?OOOO 2

2 220 00.-

0 0

40 35 to0 0 0 0, 0 0 0 2 2

30 2

022 0

aMOO 25 20 15 10 5

001: :: :

45 40 35 45 25 20 15 00...

.a.

a I..

22~ ~

..... K ::....

a....

02a 2a...................

0 02 a

.0..0. 1.3 o

o iI on

° 13 0....

0.

.................... 00 000T]

.0 OO 0

0 Q

100M

[]D*a 0...I-0 0),,,,

0-0 O.

0

)0

,(

.0""

S.

0.

0 0

0....

0 0

0.

a......

.00.....

00 0____

.__0 00

.0."

00..

0

0.

00)0....

0.........

0 0

3 0

0.....

0 00o.

.00

0.

'a-0.........................

00 00................................................................0 0.........

0 o*

a............................I*.....................

0 0....

.T..

.o 0..............

0 0

0 00 0

O0

0.
o...........

oo....0.

E 0

0 a0 00--

I----.----ý0 0

0

0.

.0

.),.

o

,..,. 0 0000(

0000()

0:

000 0('

""G 0.

0.,

"0

00.

0000..

.000.

.0'

(

.0000.0000.000......

0000000 O0400 000000.

0..........

00..1..

0 T......................

'.0o t.........T.....................................................

: i : :...........................
: i....00:i
: ::tT:

° t

~000 0

00.

O 0o t o o....

13 S....

0000....

0.

f 0,::

00 00..

000....0.

oo.

1, T....

0 0

25 35 15 10 5

5 00...

0000(

)0000, 0000/

,0.

)0000

)0000 o-"[0000 0

.- 0 aoooopaoooqaooo~poo00cp000090000 ooo0onoa~o/oaaoooooopo0009oooo~oo000 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 Westinghouse Electric Company LLC - ST Max 10/23/2009 10:15:08 15 10 5

SG-B HOT LEG TOP OF TUBESHEET PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 S 1626 Tested TSH -18 Through TSH +4 Inches a

49 PLUGGED TUBE

.10 105 95 85 80 75 IOOOSSOOOPSSOO 70 65 9osso 090SM

-SS ss.. SS 60 90O 55 ST0OOO oI'-

. SS..

ss.-

'0 0

45 40 S000?SS00 0SSO S.

S 35 30 pcosoV.

.000 25 20 15 10 5

aa.S.

s-IS

,H S

S

-*S.

S 45 40 35 30 25 20 15

,','S

.s

.*S

.. z.SS-

.. S

-S,o S

S SS -

SS-SS

-s s',,

DOS,.

S SS SS..........SS 0 S

S

-SS

.s

-S 5 Sam ooS

-.. S....

S SS......

SS.-SS..

SS.

.. SS...

s:,ssoo s.s.......ss 0

as".,

.s.s

... s:SSOO

.. ss SS..

SS.

0SSo S....

.SS.

Ss S oo S...

S S.

0.

0

,sss

.ss s.

ss...s.

.s.....

s S

s s.oI' osss S

S...,ss o

ss.

oS S 0

. S.o ss..

ss..

... S*ss S.o,

OO "SSS

  • "SSt'.'S SS.o

-SS"

"'SS 0 S S.

SS..

SS-SS s

S.

.1SS.S Os...

.ss 0 ss...

sS s - *s....

s.....ss.o sO..

. S ss.

s s

ss.

s s o S I

  • aS S IS S S**S ss-.

-SS t..°. S s..*

SS....

SS.

-ss 0o S

0

s.

SS S:ss o

-6 O

oo0 s

SS,-..

S. S SS 0 S.s s

s ss.

ss.

.SSI..

ss.. s.SS.

s S.

o... sss.. ss..

s

,:S SS ss....SS 0 s

.... S....

ss 0

SS*

SSS --SS...

S.

S- -SS.........SS 0 S S...

SSV--S S

SSo SSS,.SS S/

.-.SS....oSS....

SS 0

S o o SooisS..

-SS*

-*SS:o--

SS..

S-

.,S 00SS SS

  • S-S
    • S*

SS......S 0SS

-!I*SS S.S~

ss.

  • S Os 0..s;..

ss.

.. ss{...s ss..s...T:SS*st ss

.s.SS.

  • 0S S

S o

oS:

  • S S.o..

=:

,,i

==

S.

0s s

os!o

.os.

s...

"S S:

==

..-==="

o..

s......ss....ss.....

s...... s s

s.....

ss......ss

... s S.....

ss.

S s...-SS

.- S o S.

s.

s.

SsS

.s...S SS.

S..., SS.s..SS.O ss.

... s......

s$s

.ss.

ss:.... s sS.

ss.

ss--

.s

.0o So 85S SS

.S.

"S---.

S.S...

t- ---

S=

SSS.- -

13S*-.-

=

8-l o.:.-1 SS s s,--ss.

.s S....',"

s..

s... -... t..SS t"*'.s.... ýs...fs$. j.

SS

.s S...

S ss..

s....

ss....

ss...

o~~.............fs.. t~s.........s.........s.....................

s-s....ss sss.. s...

ss-..s

,o o S s...SSS s

S.........

S s0 s..S SS *..SS...oS

I SS S,.
S :

0.. s..o.*ss*.i s

... ss.oos*...

S...s................ot°°°

s...fss..

ss

.ss, ooos s.*s..

ss.o.ss.L..s SS.

,S..

S.. s..

.s." s.

S 0

~..

- - I 00..:S...i

ýSS--

S SS

-ss.

.S"

.I.

.l s!....

S.

S Ss.

-. SS....

S S..,

SS..

ss.;

0 S::

S

-S,-

45 40 35 25 20 15 5

5 00..

0000 ISOOO$SS 0P..Vsssý 110 105 100

.Ss Ss OOSS(

s000S Y

I'-

I- -

  • .Ss.

IS...

s..

S..

0000$S50009S000,

)0000 00S

...ss...TSS....

ss' 0000$S000qSSoo$~oS50c ss

  • . ss
  • . ss

ý S.

ýSS.O I

3S....

SS:-1 SS

.. SS I

S....SS !:Ss*.1 SS SS... SS----SS

>S I

SS (bOOSS

ýs 0 OOýSS.O(Do 0.

)0000

)OOSS9000S 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electnc Company LLC - ST Max 10/22/2009 20:23:02

SG-B HOT LEG LOW ROW U-BEND PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 X 67 Tested 11H Through 11C a 49 PLUGGED TUBE 110 105 100 95 90 85 80 75 70 65 60 aoooo0ooo0000ooooo$0,000o0o 55 50 45 40 35 30 25 20 o0OOO0)0o0oQooooQ0OOOOpoooa I

I L5 10 alla. **

t....

13 0

0 0

01130-0 45 40 35 30 25 go.

0 0

0 00.

0 0.........

f 00..

T.............................

0 0

100 13 o

....... 0 00.

T.......

00.................................

0...............

T....

T............

t

÷....

I....

T....

I.........

..... o

.. t..00 o....

0...........

0 T.....

0 0.i t

0'1 -0 0

0.............

.o.............................0o 0oo......

÷

+....

TTI............................

.. 000 0............0 0........

0 0.....

00.00 0

0 e

f

,0 0i G_

45 40 35 00 00.

0.,

00.

00.o 0

0 0

0 0o 0~

0*

O0

  • 00(

o.0..

00

-00

.00 0(

00 0.

0 0

0 0

0O 00 0,

)0 00

.0 0..

00.~

0..~

0.0..

0.0 (

00(

,,.0

,,,0 0°°,

.O,..

0°.

I.°..

°0...

0000

,0000(

( D000OOOOOQ....

0

l.
,0,

.o...

I 0o

t::o 30 25 20 20
  • 0 0,000,O0000O0000O0000Q0000(

0 0(O0 O0 4....

15 10 5

i ii..

0000::::i

...... :... :.....T....*..*...*..

0 -o!

0!!~

!! i i

0000::............................

T

..' t ooo.

0 t.....

' ' -.0 o0.,

. t....

oll.....

0 t..

...........° o *

  • T... iiii i....l

.... 0000o 00÷..

o.......

I 0

0 000.

....... I....

..o.....I........................

j...2 0

  • T I :

.... !......... T...

T :

  • T.

.T...

.o 15 10 5

ox..:

ooXo *ooo Xboo X o(oXX XooXo 110 105 100 95 90 x.

.7

.6 6...

0 5..

5

.5 x..0

3. 3 ioxoo*,X~O~O*XXO~OXXýOOO oxxl~~xoo,XoXo 0oox0X hoXo(:ooooX~ooxoXoox0ooioXoo 90 85 80 75 70 65 60 55 50 45 40 35 30 I....

.. t i...-

x x..

x...,..x...x.x.--xo XoooXoooX9P0ooXoqoXoXooXo 25 20 15 10 5

Westinghouse Electic Company LLC -ST Max 10/22/2009 20:23:00

SG-B COLD LEG EXPANDED BAFFLE/CORNER PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 2

4 TESTED 02C +/-

3' X 29 TESTED 02C AND 03C +/- 3" a 49 PLUGGED TUBE 10 105 100 95 90 85 80 75

-XOOXOOO¶XOOX nan°°:..

70 OOXO X,

65 60 55 50 45 40 35 30 25 20 15 10 X. X x O ::X

...x1....

n...

coo 0..

°...-

5 QO*D

  • OQm 45 35 30 25 20 15 a

ana..

. X 0....

22..........

0 a X÷ T

o..............

0..................................

2 7

0:

X:

I 0

I..

cc:*

0-................. X........00 0 0 0 0.

[

O 0

0O(

0 X

.O 11 O.

.."O..

0 o

0 0........

0

0.

0 0 0 00 0..

0 0

0 0.......................................

o. oo...........

o o0 0

.O 0 0.

0.....

I.....

.o 0.° )0e 0°°

.e I

0e°

.°.0

_0.

Vc 1

1 7

4 777::

00_

0..............

00....

T

.....T................

o÷.0 0

.T.

.T

~ ~

~i o

o..

I

...:1 :.

I...

o.......................................

T

.T..

.T.

0',.

e

.ee

° 0

.ee

°

°*

e*

~~~~ ~ ~~~~............

  • i....

i....

I I..

oo.

0

00.

0..0 oo..

oo..

........ 0 o. -7 7

00:

0 0

o...

0....:

O 0 0 00 0(

0

..l..

..T..

..T..T..

o.

0 l

, I.......

°....

0 0

0................................

0 0...

0..........

O O...........

0 T

00 0

T i

i.....

00.

.... o 0.

o I

... I

.....1- *-...1..- -

1 -

o..

~ o.. i f I

...T..

.i....

T....

0

" ? " I.

0

. ° °.

i....

... "0

o......

.. o *. I Z : : :

I

o o +..
o.

I 00:

o. ': : : :.....

00

.000:(:

00 45 35 30 25 20 15 10 5

5 0

...I.... ;.... t....1 :

o0 1::::

.I:

O...

°..

° 0 0 0 0 0 0 0 0 0 O O O ( q O O O O ( ) O O O O ) O O0 O lie 105 100 95 90 I

-*.000.

I0 I-

'01 8

0ooo7oooo o 0

ooo; 85 80 75 70 65 60 55 50 45 40 35 30 Soooo0oooo0oooo0 ooooqoooo 25 20 15 10 5

Westinghouse Electric Company LLC - ST Max 10/2312009 13:33:16

SG-C HOT LEG TOP OF TUBE SHEET PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 a

65 PLUGGED TUBE S 1618 TESTED TSH - 18 THROUGH TSH +

4 INCHES 110 105 100 95 90 85 80 75 0000SSSSo ss00

  • sss 70
)0sso vS S

.ss.

65

  • .ss
  • .ss 60 t00 Cos 00* S a

s s

a a]

55 50 45 40 oooo00SooocSSMoT0SS S.

s

.ss

... S so TOSS 35 30

.oossss V.SSSS

  • SS§,Soo]

-"SSsS.-Do 25 15 5

45 35 25 20 15 S

  • S....S5S.

SS....

.....s S..

ss.

-S

..S I00 os '.

.s..

s. 's :

s -SSS'

.o0 oSS SS

.S

.SS*

- -SSa S..s

  • -o 0I oass

..S....

sss

.ss

..ss..

.ss S 1....

3 a

a S...SS-

.S.S ss ".

S oS

,SS S

S G

6*...T SS

-S.

-*.o$

s

o. Ss....

SSSa 5S

  • .S 0

S....

ss.

s S-S-S OSo: ::*s

S"-

ss

° SS :

0 sa SS 0 S..

s

- O

1 sl.

0 gs 0 SS.**5..

S SS5.,SS.........S S S *....ss....Vs

.f.t.s

.*,s.5 *.*.... *oo oss....

s...

sss

... ss 0 s....

s--- ss-.

-so.

.ass s..s oo..as..o 0oss...

iss5 o,

ss0 0

S s

0 S....

  • s.oo ss*..
s.

s.. S 00o..

s--oS 00oss

-s...

s s..sS is 00a s

s.... S~

4 (S S..

Ssss.s.

ss 0

s o Ss s

ssss-ss.o ss..

ss o s

s o ss

0.

S...ssss..s s

SS SS.I.......

.SS 0 S

s

.o.0

  • Sss5..

_o$

o ooI*..............................................

o o.*........

. +. o

, s..

. I..

s s

S s

0..

s.....s...

sss s..0 ss-...

TS

[

S...

ss...

sss s

s....

ss s

s I

s.

sss s

ssS...s....

ss..

S.

s SS.

ss..

.. SS 0

s....

ss

.s....SSS

.,s ss...sso S0 S..

S..s..S 0-...

S SS....S..

ss s

.s........

s SS 0 s-..

SS

--S...

S...

ss-.

o

.SS.

..S SS 5

0..

$SSS.

S

.s..

O S

{SSO S00 o

000 SS-.

t S S S

0.s s.

s.

ss

-s SE ssss..ss

_o.

.5..

S....

E)

SSS-a 0OSS E) ooooa o SS i

o....

..ss...

s.i. s 1....

sso....

.. s ss.. -s o0 j

Sss.os.

o o:soo o. ss......

t..sss,.s 5s...*,

s--t so. ssoo.ss.

..- ss... s!o... ;sss Iss..,

s I

S Ss.Ss.

t. ss.

s s. +

s... so s...

S..

-Ssss-Ss

.S 8

ssS Ss

.. SSSS.-s.

SS-.

SSo SSSS S..

ss..

.SS-s s

o.

s. <,s:

l ss

s.
  • ... *s s

.s

. ss-o

,S --.

+.

.+

l S...

-- SS$

s SS o o S.,

S o.. s.

.ss.+

s..

Io s...

sss.

s- -....-

oo s.

.-s -.. Iss..

.s.... ss~soo-s...* =. s.

  • ss.,

t s

S sS S

s S

s s

I

/s

/

s

0..

s..

s..

sss s...

s ss. s - {

.... t

.....s.

. s-.

Ss.*

s.

i-ss s.s

s..

ss..*. ss s s 0o..

o "s 0 ".

i'.'o

.oo

"'*o " "*....

SS ' *' " "

.. Io*'

oo"....

o

..S s..

ooso....

4 s s o* ' " {* "

.........S' S

s.

{'*'s*-

.. :: j s.o*:.

SSo 45 35 30 25 15 10 5

00..

0000 s

S*s I -ss*

K

Its::

ss:

ss ss ss SII.... +sss.

.ssss.

ooooSSSo.So o.

SS S

s S...

ooooS00qooo S0ý-so
  • .ssss..s ooSSSSoos S...
  • S***.33 SSSS

....$S

,ssss

$S'--

,~ssss ooo~oo

c

'ssss

)00ssý000sý

)00004$0000$00Os!

110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse EIctric Company LLC - STMax 10/22J2009 20:26:14

SG-C HOT LEG LOW ROW U-BEND PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 X 64 Tested 11H Through 11C a 65 PLUGGED TUBE 110 105 100 95 90 85 80 75 70 65 60 0000$0000Q00000000(P0000()O o0 o 0.. #....

a 0

0 0

a 55 50 45 40

  • O00000000T00 0 0 00000 t........... 2....

35 30 o

000 o01 25 20 15 10 a OOf.....

0)o..f.... f....I 45 35 30 25 20 15 oo=:00....

.... T..........

... 1i......o.......

[..

== i T

T'... T*

I:i

=o 00..........

0 00

00..................

00 o0.

0 00..........

T...

0 0

0 O.

".00:

o0o00.....

!o 00

0.

o......o............

oo....

00 000 0

0..

o o...........

0.0..........

o.

T.

.T 0000000 0

0 0....T...............0 oo o

o I..

............ I............

0......

0 0000 000..

~CBT~..........

0.

I 0

0 00................000o.o.........................................0000.....................0 oco...

000.oo.

. o..

0

° 0

000.

000......T.....

0 0

0001 00....

"° I.

I I

T....

.................. 0oooo...

ooo... ooo.. ooo.. o.o.

o i....1

(...

I °

(

o

0.

0..

0

- - l -- i ' *,.

00o T...

..00:!

0

.0

()

o

.I.

o*.

0 00(

  • ° l

°

.o.o, 0

0.

0...

0......

1:0:....0T0....

i

..0 0..

i

  • °OO

.c...

0..

o 0

.0.......

0 I

...Iool T.

. T..

°.... *..*.......i i i i i i i..................

0 Joo

.. T T-...

I -

o 45 40 35 30 25 20 15 5

5 0.:

0..*

0o XX ooXX 110 105 100

,O@JO

,Ol00 I.

X...

x.*..

$T,. X i... *.

f..

.. X 55 5x 0 45..

4..

(]

XX 0OOO0 OOOpoxOO 55 50 45 40 t

.. XX*

jxX.

35ooxo3xo 35 30 oXXo5P o2X 25 20 0

/-X...

OX* oO 1000X 000X 15 10 5

xxooopoooo(oxxopooox)ooxxxoooo(poOOX(poooo 95 90 85 80 75 70 65 60 Westinghouse Electric Company LLC - ST Max 1012212009 20:26:12

SG-C COLD LEG EXPANDED BAFFLE/CORNER TUBES PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 2 17 TESTED 02C +/-

3" a 65 PLUGGED TUBE 110 105 100 95 90 85 80 75

.2.2.

t....

70 D0000q 65 60 I0000 0

0

,,a 55 50 45 40 O OOOOO000 00$0 0000000 020 0,

35 30 25 20 15 JIooo 2 I 00021 202 13°

° 0

.5 o

~

~

IP a

45 40 35 25 o0

............... 13...

11 3.

..o 2 2...

2o 2 20-1

. °

° 00.......

= 1 0 4.

.I

.T..

.I2

~~~........

  • : : : : I : : : :

......... T: [3

,o ~~~~

~....

00...

--c

.. :.o o o o..

00 o o.... :,

I..

......T..

"° T...

I o....

0 (DO.......0 0 00. T.. "

0 oo 1

(0.....( )...

........T.'.°0 °°...... o o0....

0 0...

13

.3o0 o

O D: - :,o o0

.... T...0 00....

..T..

..I..

°°...

0

. o o....

i......... !..I.

I...-

0 0

.T..

0 0..

OO....

O.Ol.....

0

0.

.?..

O O

O *T T...

0 0.....

I T

.... I....

I T..

.T....

o 00T....

I....

I 0o o ooo oo o o o.o o......

T......

I....

I o

i i

i:

....... I.... I I

l....

T........

.T

...T.

.i.

°....,..I..

1 2 2 1

: : : i : :..

.f T.....

T...

00 00 0 000 00 00 0

o 0

0:

T T

00: -.00:;7 0....

:..i..*..

....0 1..

I I

.~

l 0 0 0.

. T..

.. T.

. T.

o, * * "

`0.

T...

`0..

.T... i.

1° 0

T...

0o )

o.

.oo

.o o

II_*I I

00.. ~.,

. o o

..l.

°...

o:1 0...

I.......

oo o..........

  • ..... oooo................ o o...
  • O.

O TO...

00 0.......

!......... T 0I T

.I 45 40 35 15 10 5

15 10 5

I I

2........

T....

T....

)0000900004O000ol

)0000$O0 000 V~"v...0 0

oooo0booo00boooo00oooojboooo O-...

oooo0oooo0oooo0oooo0oo0P00ifoo, 0000opooooý0000opoooo(POOoo00ooo6oooo, 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electric Company LLC - ST Max 10/2312009 13:35:27

SG-D HOT LEG TOP OF TUBESHEET PLUS POINT NSPECTION AS TESTED Braidwood A2R14 CDE D5 S 1617 TESTED TSH -

18 THROUGH TSH

+4 INCHES a

26 PLUGGED TUBE 110 105 100 95 90 s

sss 0Ssss 85 80 75 00o00Sooo sSOO So... ss...

.... s-i*

70 Sosso f* ss.

~.Ss.

65 0Doss V.Ss V.ss 60 (Po a

a a

55 50 45 40 35 30 00.1ooo 330iSS oooos S

s..O 0

S.

I s

. I.ss

. s 25 00

  • 0 s 20 L5 45 45 35 25 20 15 10 5

SS.

  • S S..

S......S s 0 S..

  • ~.

S S *s ss~

ss,. *s 00 oss s SSS 1 s.

.ss.

  • ss 0

a, SS :

s.5:

  • ss

~S

.00 COSS..ss SS S

S-SS 13 S

.~.

1

.55-s-

s.,

s.S.00 (05ss-.ss S.. S.

ss...........s a 5.

5.

SS S.55.s.

.. o SS.

  • su sss SS S.

........... ss, 0 s..

~.

  • ss*

i-ss-~

s*~

  • ~

..--.--. ýsoo--

s -

o

s ::
Is

..SS 0s S

..S V

S. *SS** 00..S5.00 0

0

  • S*:~S S. **

S.

OSS

  • S
  • ~SSS S5 OSS.
  • S S*

I:S oss.

  • ss *SSS
  • S S~

S...

  • S S~

S***S S*

S 00..sS 0

s...

S.

SS sss ss.

    • s s

0'~~~~~...

.SSO S****.~s...s..

so 5

s.......

S..s... ss 0.

? :v
5 v
.Is:::.,Os
  • S"S*:
S5 *SSS.... S**...SS...........SS0 5
  • S Is s

SSOO

s s

s sss.. :S:

~...

.....s....sýýS s

ss,.

s s

.soS S

S-S--

___sss S

6-- S

-S..........

SO_

Ss-ý S

ýS.SS

..SS.5ss....

sss 0

S..............

ss C I

I-0..ssO ss..ss SS

.Ss S.

OS SO osS. s0S 0000. S.00.

s SS.

s:Io s

.... S... s..

0 s

SO*

.So.ss.

  • s sss
o.

.s.

. 7ss.

  • s s0 s

s s

S s

s-s 0

0ss

  • ss
  • sss!...

S.

..j s s

s s0s.

.i~

cSS..s.55 0

S s

-s

.SSs S

  • 55 s

so s?

s I

s

...S 0"Ts00):s

-:ssss 0

.S os sooSs Q.0..S0)S s..

S.

.S.

  • ss *sss...

s.. ss.......

s ss

... s*

s 1-

.. s*

s

~

S.......

0s S

ý S :ss:..:S" sss

-s 5::: 53:'35 S!..S ss

-s S.

  • s0 sS.:: :SS::,,:SS- ::55 ss

....S..:::{

ss....

Ss...0 SS....

s :

.S :.~::s s Sl.s.~.JS00S.:

IOO S.

f s s Oss s.

sSS SS........

s SS SS13*.s 35 25 15 5

o s s S.

o s SS S

s SS-s oo Sooo SSoo( oSSOOOSS 110 105 100 95 sss t:::t...

I ss.:

sss s-

- - I ss.

sss 90sss 90 85 80 75 7070 s

.S 55 50 45 40 s

.... I SS

  • SS 2ss0 1'5-ss oooSooo o

SS qsooi~SS 25 20 15 10 5

60000cp0s 65 60 35oss3oooS 35 30 Westinghouse Electric Company LLC - ST Max 10/22/2009 20:28:48

SG-D HOT LEG LOW ROW U-BEND PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 X 68 Tested 11H Through 11C a 26 PLUGGED TUBE 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 Soooo*)ooooq 0

oooo 00oooo0oooo0o o 0ooooooooioooo0oooo oo 0000 O0O..T0 0 ý -

a 0

o.

../

D

.000 ooo0 a

o1.

00 5

45 40 35 30 25 00o 0

00....00 00.......

o 0

I.........

. 00 0...

0....

0o...

0

-00:

o*

T..

  • +

00.......................

T 00.... 00..........

0 0

oo..........

T.....I...

........... oo÷

  • .0000...

.i o

.o 0........00

"* "0 o÷....

Io 0..

0 0.....

00..

O0.

00--

0 0

0 0

T D

00....................

0 00............0 0

0....

.00 00

=
=

0 0....

0 0

.T..

o o +.

T..

T.

0...................................

I....

T....

I 0.....o o,

T....

T.........

T.................

s 00............

0 o.

oo.

o 1.......

0T0 0000 0 0 0000000:

00.....

I T.....

0

............................................ T.

I l........

1.........

T....

1..........................

T.... =....

T 0

0..

...0 0....

0 00...0 0....T 00 I

,*ý

,:.(O OT O

()

O T

O O

0 co....

t ~~

~........

t

. :: Z j....

0o

.T..

T..

1..

.T..

.T..

..T....

........... 11...

.T...

o..

..i......

.T........

oo:

1

...t !:

I

.......1 oo....

Ioo I

0....

I.

T.

0o o

? _

0.....I....

(,

I.

0.

I.

.. 00 0

00..

o.

T..T O

O

(

D O

O V 00

OT'-,

O

-- 0..

o....

  • ........................::: :::.......... I.......1::
: ::::......1..

.Ot I i,

.45 40 35 25 20 15 15 5

5 00..

0. XX ooXX( -X*ýOoxoýoxx,(,

)00X0 X XX0 0000 XX.

I I

I U::::i,.::: :;x'::;

oooo0 X0o oxooxxo o o... oo, I I *0 0

X - -X XooX;

XX(..;...

X..-.

X....

00X0IýXXX0It000X*000X*0000IýIxx0I xxoopooxx:

110 105 100 95 90 85 80 75 70 65 60 Westmnghouse Electnic Company LLC - ST Max 10122V2009 20:28:46 55 50 45 40 35 30 25 20 15 10 5

SG-D COLD LEG EXPANDED BAFFLE/CORNER PLUS POINT INSPECTION AS TESTED Braidwood A2R14 CDE D5 2 36 TESTED 02C +/-3" a 26 PLUGGED TUBE 110 105 00 95 90 85 80 75 70 1

1 12000000000000,000000 2;

222 22..

65 60 55 50 45 40 35 30 t00001~0 010000OpOO000OOPOOTOO00 00021

.a I

  • 222 a

00 :

2 25 20 15 10 22

-22 45 35 25

........................................... oo...0::

T...*

2 2'

00:

tZ:::,...

,...0 0..o°.....................:::

S I

I T

0.............

0 0 o....

oo.~~~~~.. o.

....i..

.. i

,Gii 1

'-a0..-.

0....0 Ea.

.o.

0.......

0 00 0.......

0 0....

oo..

S0 0

0...

00o

.00 0....

.0........0_oo 0.........

o.o....

o0_

0

.. 0 0{

00" 1....

T(

0.

0 J..

0..........

0......

0..

_o 00 0................

0 00 0

0 0 00.

0.....

.o....

o

.o o0:: ::0 :::

-ii I I *-

o:.... --

.... o..0..o 0

0 0

) * "..

o o ~ o o ~ o o *..,...

.....0..o I ".......

"" "1

.1 **

.. Joooo,.ooo e.......

I 0

0 0

0 i

i il i!

0,

0.

0 0 0 0 0 0 0 0 0 0 0 0 0 0 1:

0 0 :

0.....

0 00.

Tj 0..

.....0................

l I......

ll o

j:::
.o 0o.

o~

..l...

..* oo.

0*

00.-...

o.....o.o

o.............

..0

.o

  • .I/TIt
o.
0.

to o

.i..

0 oo o1..

- 0 0.........

o o.

°i.......

... 1 T

T........

T 0.....

oo0

: : : l :.......

. : : ! : : : : ' o 45 40 35 25 20 15 15 5

5 0o0-000- 1...

1.. 21 1..

... 122...

12....

1 110 105 100 9.....

80 7

0 000000 0

0 0 0 0 )0000 q0 00 09*00 00$*0 0 00 l 0 0 00 0 00 0 lie 105 100 95 90 85 8@

75 70 65

)0000$0000 I

0 0'

PO000O00ooooo000090000(poo000 60 55 50 45 40 0oooo0oooo0ooooooo0000ooo0 25 20 15 10 5

35 30 Westn9house Electnc Company LLC - ST Max 10/23/2009 10:31:41

Attachment B.3 As-tested +PointTM Special Interest Inspection Maps

SG - A EC BASED PLUS POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X

6 TUBE WITH EC BASED SI a 83 PLUGGED TUBE

.10 105 100 95 90 0

85 80 75 70 65 60 SOOOOpooooqoooo(poooo)poooo*o 55 50 45 40 oTooooTooooTooooToooo0 35 30

( (

0 T00040o~

25 00(0-...

,0 00..

T....

o I-o

.I3 0

0 0

20 15 10 5

000 a.000 v

45 40 35 30 25 20 15 a

00..

0 3....

13.

00 00.....

0

°....

  • O::O*

~0.

0 0......................

..........-.o::*

000 0 0..............................

" T 0,

o.............

T

.....T....

T.........

o 00 000.....

0 0

T1......

".'°°.

0....X...

0 0..

0

0.

0.0..............

0..

o 0

0 1:10011:101 -

0 0 o..............

?

.......... T.......

o o.................

o...............0

,oo...

.. T..

.. o÷..

1 0 )0 0 0....

0..

()

0..

o O.

0 00..................

0..

0...

0.

00i..c0

00) 0 000.0 00 0o0

...............T

..... o0,0

° "......

0 1..::::

00 0.0......

O O......

0 I....

I....

00,

.... I......

.... I....

00 0.1 0....

0

.. I.

o...

.0000.

0 0

F,-

,,,O()o,,*,x

  • O O

(O 0

(00 00 0 ::,::

":0.. X::"

0

,:00 oo

  • .o.

.T.

.T....

o.. ÷...

° " 'T

... T....

00..

T..

.0..

0 " T..

: 1...
  • : i:..

o oo.o o.o o ~ o o ~

o...T.

o0 " T..

l :: i
...l "

" ' T

.... T..............

... T.

. T..

I.

.i 0

o~~~~~~~

"..T" T '

0 :

...I 1TT

°

-3

...T...

I..

OTO:

0o 0

T ;

oo.

T.

T......

00 00..

.. T.

0..... OTo o~..........

.0.....

0 0*

I 0.-

i....

00.... I-o 0..........

.0000

. 0..

°

" " ° o

~ o..

I

...o.o......

o

°..

..*..........................'.....i i t i..........

0 45 40 35 25 15 5

5 0...

0.

).0.. 0

)0oOO/T1aOOO

.*0.

:::: :: 0 0 0 0 0

00090000P0%00 1:111:11:0,

.0000,,0000*0 0

o)o....I

,000pocow

)00 00 po/00 009000 0000009P0000 1000090000900009000090000oo 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 Westinghouse Electic Company LLC - ST Max 10212009 20:14:54 5

SG -

A EC BASED PLUS POINT SPECIAL INTEREST PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 14:18:08

+ - -

+ -

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷....

÷....

+----+

"----÷--

-+

+----

÷ 24 24 24 19 19 19 NDF 2.31 187 DNG NDF 2

P1 P1 TSH 07H 07H

-2.56 17.04 17.04 TSH TSH TEC TEH 07H 08H

.610 NPSNM

.610 ZBAZC

.610 NPSNM 7

HI 43 HI 103 HI 20 27

.39 84 NOS P1 TSH 1.32 TEC TEH

.610 ZBAZC 33 HI 20 27 NDF 2

TSH 1.32 TSH 01H

.610 NPSNM 123 HI 31 52

.18 114 DSS P1 01H

.84 TEC TEH

.610 ZBAZC 51 HI 31 52 2.70 186 DNG P1 11H 9.51 TEC TEH

.610 ZBAZC 51 HI 31 52 3.12 184 DNG P1 11H 10.81 TEC TEH

.610 ZBAZC 51 HI 31 52 4.15 183 DNG P1 11H 12.16 TEC TEH

.610 ZBAZC 51 HI 31 52 INF 11 O1H

.00 O1H 01H

.610 NPSNM 103 HI 31 52

.25 264 PCT 26 2

01H

.43 01H OIH

.610 NPSNM 103 HI 31 52

.18 71 VOL P4 01H

.46 01H 01H

.610 NPSNM 103 HI 31 52 PBC P1 TEC TEH

.610 SBACC 119 HI 31 52

.23 120 PID P1 01H

.28 TEC TEH

.610 SBACC 119 HI 24 76

.28 111 DFS 1

TSH 2.15 TEC TEH

.610 ZBAZC 63 HI 24 76

.19 153 DFS 1

06C 11.60 TEC TEH

.610 ZBAZC 63 HI 24 76 NDF 2

TSH 2.15 TSH 01H

.610 NPSNM 103 HI 38 82 NDF 2

06C 16.90 06C 07C

.610 NPSNM 6

CI 38 82

.14 144 DFS 1

06C 16.90 TEC TEH

.610 ZBAZC 57 HI 35 94

.19 91 DSS P1 01H

.00 TEC TEH

.610 ZBAZC 57 HI 35 94 NDF 2

01H

.00 01H 01H

.610 NPSNM 103 HI 35 94 PBC P1 TEC TEH

.610 SBACC 119 HI

+----+------------+--

+----+----+-

.+-

+---

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI Tubes: 6 Records: 22 1

ST Max

SG-A HOT LEG APPENDIX 12.8 + POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X 72 TUBE ON HL APPENDIX 12.8 a 83 PLUGGED TUBE 110 105 100 95 90 85 80 75 I

~0 0000TO0000T0000,

I I I IO1 O...

70 (P0000 000 00..

65 60 55 50 45 40 0 0 0 0,0 OOT OOpOITTT00000000 a 0' 0....

T..

.I.

35 (I)00001 0.00*

30 25 20 15 10 45 35 25

~.i=

-- :==

-=

=_

__==-_-o 00.....

1 T.....

00-

  • , M.

.3-::

a an 010...

0:

00 0

o....

o(

00 00

0.

°............

0 S7000 Too 0

0.......

o000.

0 X.

0 o.[ ].

...... 0.

..~x x.

.. 0...........

-*0

  • 0 O
o e--

I 1-S....

.0 0 000 0.....0 0..0 0.0 00 oo.0.....

0 X

I

:. o I

0

0.

I.........

o 0 o0...

° T....

0.........

0 o.

o

÷.........

T i

I........

00 -

10 O

.T...

o.
  • T I

):

I...

.00 70:

00 0 ~~~~~~~~~~......

0 0D.......T......oo,.ooo

,ooo.......*

00000 I

o

o.

I I

I (0.........010..................

0

.0.

0.

.T..

.i....

...... 0..J Irf

  • i I

0....

T " T :

7T: : T' 7

I,:

......... 1 0*'

0o....... *...................

i 0::

" T......

XX 'xx :

0 0o 0

0..

T" o*.

xx xx-...............

XX:

ooo00.

0.

. t..................... T::::i:::*, *...[O o...:.o0 o)

o. o...... oooX 000...

x 0-o..

....0.

=:x o

0 1

oo........

0....:

-00...

t T

0::::0.

.0:

i 1::

: t.

..t.

o o0 45 40 35 30 15 10 5

20 15 10 5

0...

a 0 000.

0000(

'00001

)000010004(

a..o

° -0

,,0 00001p000oooo~p00p00001P00001paaaoqpa0009a000ga000 l000019000PD?0000p0000,

'0moa0o1o ooo00o00000000oooo 15 10 5

110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 Westinghouse Electric Company LLC - ST Max 1012212009 20:14:55

SG -

A HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:07:56

+.----------------..----+-------+--

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+---------+-----....+-----+

+

+-

28 50 NDF 2

TSH

-11.30 TSH TSH

.610 NPSNM 5

HI

'28 50 NDD TEC TEH

.610 ZBAZC 51 HI 28 50 NDD 01H 01H

.610 NPSNM 121 HI 29 50 NDD TSH TSH

.610 NPSNM 5

HI 29 50 NDD TEC TEH

.610 ZBAZC 51 HI 29 50 NDD 01H 01H

.610 NPSNM 113 HI 30 50 NDD TSH TSH

.610 NPSNM 5

HI 30 50 3.05 70 MBM 6

10C 12.29 TEC TEH

.610 ZBAZC 51 HI 30 50 2.31 243 INR 6

10C 12.40 TEC TEH

.610 ZBAZC 51 HI 30 50 2.94 69 MBM 6

10C 18.89 TEC TEH

.610 ZBAZC 51 HI 30 50

.14 63 DFS 1

09C 4.75 TEC TEH

.610 ZBAZC 51 HI 30 50 NDD 01H 01H

.610 NPSNM 113 HI 31 50 NDD TSH TSH

.610 NPSNM 5

HI 31 50 NDD TEC TEH

.610 ZBAZC 51 HI 31 50 NDD 01H 01H

.610 NPSNM 113 HI 32 50 NDD TSH TSH

.610 NPSNM 5

HI 32 50 4.03 75 MBM 6

01H 1.70 TEC TEH

.610 ZBAZC 51 HI 32 50 NDF 2

01H 1.70 01H 01H

.610 NPSNM 113 HI 33 50 NDD TSH TSH

.610 NPSNM 5

HI 33 50 NDD TEC TEH

.610 ZBAZC 51 HI 33 50 NDD 01H 01H

.610 NPSNM 113 HI 34 50 NDD TSH TSH

.610 NPSNM 1

HI 34 50 NDD TEC TEH

.610 ZBAZC 51 HI 34 50 NDD 01H 01H

.610 NPSNM 121 HI 28 51 NDD TEC TEH

.610 ZBAZC 49 Hi 28 51 NDD 01H 01H

.610 NPSNM 121 HI 29 51 NDD TEC TEH

.610 ZBAZC 49 HI 29 51 NDD 01H 01H

.610 NPSNM 113 HI 30 51 NDD TEC TEH

.610 ZBAZC 49 HI 30 51 NDD 01H 01H

.610 NPSNM 113 HI 31 51 NDD TEC TEH

.610 ZBAZC 49 HI 31 51 NDD 01H 01H

.610 NPSNM 113 HI 32 51 NDD TEC TEH

.610 ZBAZC 49 HI 132 51 NDD 01H 01H

.610 NPSNM 113 HI 33 51 NDD TEC TEH

.610 ZBAZC 49 HI 33 51 NDD 01H 01H

.610 NPSNM 113 HI 34 51 NDD TEC TEH

.610 ZBAZC 49 HI 34 51 NDD 01H 01H

.610 NPSNM 121 HI 28 52 NDD TEC TEH

.610 ZBAZC 51 HI 28 52 NDD TSH 03H

.610 NPSNM 121 HI 29 52 NDD TEC TEH

.610 ZBAZC 51 Hi 29 52 NDD 01H 01H

.610 NPSNM 113 HI 30 52 NDD TEC TEH

.610 ZBAZC 51 HI 30 52 NDD 01H 01H

.610 NPSNM 113 HI 31 52

.18 114 DSS P1 01H

.84 TEC TEH

.610 ZBAZC 51 HI 31 52 2.70 186 DNG P1 11H 9.51 TEC TEH

.610 ZBAZC 51 HI 31 52 3.12 184 DNG P1 11H 10.81 TEC TEH

.610 ZBAZC 51 HI 31 52 4.15 183 DNG P1 11H 12.16 TEC TEH

.610 ZBAZC 51 HI

+----+.-.----+----.------

+

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----....+-....+-

+---

I ST Max

SG -

A HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:07:56

+---------------+----+----+----+----+----+----

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Ll S....

÷

+-

÷-

-÷....

+..-----

÷ 31 52 INF 11 01H

.00 01H 01H

.610 NPSNM 103 HI 31 52

.25 264 PCT 26 2

01H

.43 01H 01H

.610 NPSNM 103 HI 31 52

.18 71 VOL P4 01H

.46 01H 01H

.610 NPSNM 103 HI 31 52 PBC P1 TEC TEH

.610 SBACC 119 HI 31 52

.23 120 PID P1 01H

.28 TEC TEH

.610 SBACC 119 HI 32 52 NOD TEC TEH

.610 ZBAZC 51 HI 32 52 NDD 01H 01H

.610 NPSNM 113 HI 33 52 NDD TEC TEH

.610 ZBAZC 51 HI 33 52 NDD 01H 01H

.610 NPSNM 113 HI 34 52 NDD TEC TEH

.610 ZBAZC 51 HI 34 52 NDD 01H 01H

.610 NPSNM 121 HI I.I 28 53 NDD TEC TEH

.610 ZBAZC 49 HI 28 53 NDD TSH 03H

.610 NPSNM 121 HI 29 53 NOD TEC TEH

.610 ZBAZC 49 HI 29 53 NOD O1H O1H

.610 NPSNM 113 HI 30 53 3.40 69 MBM 6

09C 11.63 TEC TEH

.610 ZBAZC 49 HI 30 53

.06 92 VOL P4 01H

.51 01H 01H

.610 NPSNM 113 HI 30 53

.07 91 PCT 9

2 01H

.55 01H 01H

.610 NPSNM 113 HI 32 53 NOD TEC TEH

.610 ZBAZC 49 HI 32 53

.12 90 PCT 14 2

01H

.36 O1H 01H

.610 NPSNM 113 HI 32 53

.10 93 VOL P4 01H

.51 01H 01H

.610 NPSNM 113 HI 33 53 NOD TEC TEH

.610 ZBAZC 49 HI 33 53 NOD 01H 01H

.610 NPSNM 113 HI 34 53 NDD TEC TEH

.610 ZBAZC 49 HI 34 53 NDD 01H 01H

.610 NPSNM 121 HI 28 54 NOD TEC TEH

.610 ZBAZC 51 HI 28 54 NOD TSH 03H

.610 NPSNM 121 HI 29 54 NOD TEC TEH

.610 ZBAZC 51 HI 29 54 NDD 01H 01H

.610 NPSNM 113 HI 30 54 NDD TEC TEH

.610 ZBAZC 51 HI 30 54 NDD 01H 01H

.610 NPSNM 113 HI 31 54 NOD TEC TEH

.610 ZBAZC 51 HI 31 54 NOD 01H 01H

.610 NPSNM 113 HI 32 54 NOD TEC TEH

.610 ZBAZC 51 HI 32 54 NDD 01H 01H

.610 NPSNM 113 HI 33 54 NOD TEC TEH

.610 ZBAZC 51 HI 33 54 NOD 01H 01H

.610 NPSNM 113 HI 34 54

.36 63 DFS 3

11H 23.96 TEC TEH

.610 ZBAZC 51 HI 34 54 NOD 01H 01H

.610 NPSNM 121 HI 28 55 NDD TSH TSH

.610 NPSNM 1

HI 28 55 NDD TEC TEH

.610 ZBAZC 49 HI 28 55 NDD TSH 03H

.610 NPSNM 121 HI 29 55 NDD TSH TSH

.610 NPSNM 1

HI 29 55 3.52 182 DNG P1 AV3 18.36 TEC TEH

.610 ZBAZC 49 HI 29 55 2.11 177 ONG P1 02C 2.71 TEC TEH

.610 ZBAZC 49 HI 29 55 NOD 01H 01H

.610 NPSNM 121 HI

+----+------+-----+----+-----+

+----+-----+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI S....

+----..----

+-----

+-----

+-

+-

2 ST Max

SG -

A HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:07:56

+----------+..---

+-

+-

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-..

+

-+..----+-.

.+-----

30 55 NDD TSH TSH

.610 NPSNM 1

HI 30 55 NDD TEC TEH

.610 ZBAZC 49 HI 30 55 NDD 01H 01H

.610 NPSNM 121 HI 31 55 NDD TSH TSH

.610 NPSNM 1

HI 31 55 NDD TEC TEH

.610 ZBAZC 49 HI 31 55 NDD 01H 01H

.610 NPSNM 121 HI 32 55 NDF 2

TSH

-13.18 TSH TSH

.610 NPSNM 1

HI 32 55 4.29 70 MBM 6

10H 26.12 TEC TEH

.610 ZBAZC 49 HI 32 55 NDD 01H 01H

.610 NPSNM 121 HI 33 55 NDD TSH TSH

.610 NPSNM 1

HI 33 55 NDD TEC TEH

.610 ZBAZC 49 HI 33 55 NDD 01H 01H

.610 NPSNM 121 HI 34 55 NDD TSH TSH

.610 NPSNM 1

HI 34 55 NDD TEC TEH

.610 ZBAZC 49 HI 34 55 NDD 01H 01H

.610 NPSNM 121 HI 28 56 NDD TSH TSH

.610 NPSNM 3

HI 28 56 NDD TEC TEH

.610 ZBAZC 49 HI 28 56 NDD TSH 03H

.610 NPSNM 121 HI 29 56 NDD TSH TSH

.610 NPSNM 3

HI 29 56 3.44 183 DNG P1 09C 4.47 TEC TEH

.610 ZBAZC 49 HI 29 56 NDD 01H 01H

.610 NPSNM 121 HI 30 56 NDD TSH TSH

.610 NPSNM 3

HI 30 56 NDD TEC TEH

.610 ZBAZC 49 HI 30 56 NDD O1H O1H

.610 NPSNM 121 HI 31 56 NDD TSH TSH

.610 NPSNM 3

HI 31 56 NDD TEC TEH

.610 ZBAZC 49 HI 31 56 NDD 01H 91H

.610 NPSNM 121 HI 32 56 NDD TSH TSH

.610 NPSNM 3

HI 32 56 NDD TEC TEH

.610 ZBAZC 49 HI 32 56 NDD 01H 01H

.610 NPSNM 121 HI 33 56 NDD TSH TSH

.610 NPSNM 3

HI 33 56 NDD TEC TEH

.610 ZBAZC 49 HI 33 56 NDD 01H 01H

.610 NPSNM 121 HI 34 56 NDD TSH TSH

.610 NPSNM 3

HI 34 56 NDD TEC TEH

.610 ZBAZC 49 HI 34 56 NDD O1H O1H

.610 NPSNM 121 HI 10 68 NDD TEC TEH

.610 ZBAZC 73 HI 10 68 NDD 05H 05H

.610 NPSNM 103 HI 11 68 NDD TEC TEH

.610 ZBAZC 73 Hi 11 68 NDD 05H 05H

.610 NPSNM 103 HI 12 68 NDD TEC TEH

.610 ZBAZC 73 HI 12 68 NDD 05H 05H

.610 NPSNM 103 HI 13 68 NDD TEC TEH

.610 ZBAZC 73 HI 13 68 NDD 05H 05H

.610 NPSNM 103 HI 14 68 NDD TEC TEH

.610 ZBAZC 73 HI 14 68 NDD 05H 05H

.610 NPSNM 103 HI 10 69 NDD TEC TEH

.610 ZBAZC 75 HI 10 69 NDD 05H 05H

.610 NPSNM 103 HI F----------+-+....----

+----+...

+----.÷-----

+

+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+....

+"P----------+-

-+

++------+

+...

+-

-+

+

3 ST Max

SG -

A HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:07:56

+----.----.----..-----....--------

+-

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+

+-

+....----+------÷-

11 69 NDD TEC TEH

.610 ZBAZC 75 HI 11 69 NDD 05H 05H

.610 NPSNM 103 HI 12 69 NDD TEC TEH

.610 ZBAZC 75 HI 12 69 NDD 05H 05H

.610 NPSNM 103 HI 13 69 NDD TEC TEH

.610 ZBAZC 75 HI 13 69 NDD 05H 05H

.610 NPSNM 103 HI 14 69 NDD TEC TEH

.610 ZBAZC 75 HI 14 69 NDD 05H 05H

.610 NPSNM 103 HI 10 70 NDD TEC TEH

.610 ZBAZC 73 HI 10 70 NDD 05H 05H

.610 NPSNM 103 HI 11 70 NDD TEC TEH

.610 ZBAZC 73 HI 11 70 NDD 05H 05H

.610 NPSNM 103 HI 13 70 NDD TEC TEH

.610 ZBAZC 73 HI 13 70 NDD 05H 05H

.610 NPSNM 103 HI 14 70 NDD TEC TEH

.610 ZBAZC 73 HI 14 70 NDD 05H 05H

.610 NPSNM 103 HI 10 71 NDD TEC TEH

.610 ZBAZC 75 HI 10 71 NDD 05H 05H

.610 NPSNM 103 HI 11 71 NDD TEC TEH

.610 ZBAZC 75 HI 11 71 NDD 05H 05H

.610 NPSNM 103 HI 12 71 NDD TEC TEH

.610 ZBAZC 75 HI 12 71 NDD 05H 05H

.610 NPSNM 103 HI 13 71 NDD TEC TEH

.610 ZBAZC 75 HI 13 71 NDD 05H 05H

.610 NPSNM 103 HI 14 71 NDD TEC TEH

.610 ZBAZC 61 HI 14 71 NDD 05H 05H

.610 NPSNM 103 HI 1 10 72 NDD TEC TEH

.610 ZBAZC 69 HI 1 10 72 NDD 05H 05H

.610 NPSNM 103 HI 1 11 72 NDD TEC TEH

.610 ZBAZC 69 HI I 11 72 NDD 05H 05H

.610 NPSNM 103 HI 12 72 NDD TEC TEH

.610 ZBAZC 69 HI 12 72 NDD 05H 05H

.610 -NPSNM 103 HI 13 72 NDD TEC TEH

.610 ZBAZC 63 HI 13 72 NDD 05H 05H

.610 NPSNM 103 HI 14 72 NDD TEC TEH

.610 ZBAZC 63 HI 14 72 NDD 05H 05H

.610 NPSNM 103 HI

+------

+---

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+------------------+----+----+----÷

+..----+-....+-

+

Tubes: 72 Records: 178 4

ST Max

SG - B EC BASED PLUS POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X 10 TUBE WITH EC BASED SI a 49 PLUGGED TUBE 110 105 00 95 90 85 80 aoooDoooo a C 13... 4....

75 70 65 60

+.......

0 0

0 0

55 50 o1ooToooo 450000 40 35 30 25 20 15 10 OTC._

000 0

Dan aa

' : :...I....:oi 0

1..

.. 3 Q0............. I aa.............

0 I....

I.........

.. O:

00-.................................0,,a...........,...........x...,.........00 0................................li.....0 0.............................

0.....

00...........

0 oo T.........

.. 00 00.::::1:....

00 0 00.....

0.
0.

o.

o

0.

o o..:.

.o..

o....

0.

0 0...

°°'i~~~~~

~ ~ ~

..0..

...... o o

I T "

.... I.

...... °

° '"0...

.t

. o *.

.............I"'° 00:

00...........

o

o.

0 7.0 C 0 0 00 0.....

T0 O0 0-(:::

000000000000000000000000"

° 0,

...o.

...T O.

0 O ' '.

.0 0...

o...T ct o*

oo o, o o o o *.. '......

TT........ t t....

.*...o 0

0

I -

i i

I 0.

T °:

  • 1..

I

... I T*

I... :

00.

... T.

o.

o **

ii

... +.

..t..

......1, 11..!...o 0

o.

) +*...........

0 0

."1 0

, o

........o o o*.....

0... I.

ooo "0 "...

0.....

....0 0 (

  • 1 0 0.... f....

" +

o0 1..........

o....

I........

° ° " '

E)

...+.. i l

° '..*..!......° ° °,....,..

°....,....*

45 40 35 30 25 15 5

0...

0.",

00+00 o0o00$0//00 000

.oo~bl l

30 00 25 0

150 0

0 0 30 25 20 15 10 5

  • 0000

( 000 O00000000000000

)00 0 0 0 00 000l 00000o00000000 110 105 100 95 90 85 80 75 70 65 60 Wesinghouse Electnc Company LLC - ST Max 10/22/2009 20:22:54 55 50 45 40 35

SG - B EC BASED PLUS POINT SPECIAL INTEREST PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 14:19:28 S- -

÷-----------

+-

+

-÷ I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI 27 27 27 42 42 42 42 42 42 13 13 13 13 13 13 33 33 33 33 24 24 8

8 10 10 23 23 14 14 27 27 27 27 27 19 19 19 NDF NDD

.17 67 DFS 2

02C 15.86 1

02C 15.86 02C 03C TSH TSH TEC TEH

.610 NPSNM

.610 NPSNM

.610 ZBAZC 4

Cl 15 HI 55 HI 37 37

.11 140 37

.22 137 37

.34 144 37

.18 102 37 38 38

.62 170 38

.20 128 38 38

.10 88 38

.15 89 41 2.06 66 41 3.64 83 41 2.29 74 41 46 13.49 77 46 53 17.62 88 53 60 12.10 80 60 78 78 7.81 61 NDD TSH TSH

.610 NPSNM 5

HI DFS 1

03H 27.69 TEC TEH

.610 ZBAZC 55 HI DFS 1

10H 11.38 TEC TEH

.610 ZBAZC 55 HI DFS 1

10C 23.40 TEC TEH

.610 ZBAZC 55 HI DFS 1

10C 27.51 TEC TEH

.610 ZBAZC 55 HI NDF 2

03H 27.69 03H 05H

.610 NPSNM 111 HI NDD TSH TSH

.610 NPSNM 1

HI DFI 1

05H 34.98 TEC TEH

.610 ZBAZC 53 HI DFS 1

08C 3.52 TEC TEH

.610 ZBAZC 53 HI TBP 2

07H 07H

.610 NPSNM 113 HI SVI P4 07H

-. 70 07H 07H

.610 NPSNM 113 HI PCT 18 2

07H

-. 70 05H 07H

.610 NPSNM 113 HI ADS 6

TSH 2.03 TEC TEH

.610 ZBAZC 59 HI MBM 6

O1H 13.15 TEC TEH

.610 ZBAZC 59 HI MBM 6

01H 19.00 TEC TEH

.610 ZBAZC 59 HI NDF 2

TSH 2.03 01H TSH

.610 NPSNM 111 HI PLP 11 02C

.48 02C 02C

.610 NPSNM 4

CI NDD TEC TEH

.610 ZBAZC 57 HI PLP 11 02C

.45 02C 02C

.610 NPSNM 2

CI NOD TEC TEH

.610 ZBAZC 33 HI PLP 11 02C

.39 02C 02C

.610 NPSNM 2

CI NDD TEC TEH

.610 SBACC 91 Hi NDF 2

TSC

.02 TSC TSC

.610 NPSNM 4

CI DTS P4 TSC

.03 TEC TEH

.610 ZBAZC 75 HI NDF 2

03C

-. 16 03C 03C

.610 NPSNM 4

CI DSS P1 03C

-. 16 TEC TEH

.610 ZBAZC 89 HI NOD TSH TSH

.610 NPSNM 31 HI DNT P1 07H

-. 52 TEC TEH

.610 SBACC 87 HI DNT P1 07H

.57 TEC TEH

.610 SBACC 87 HI NDF 2

07H

-. 52 07H 07H

.610 NPSNM 111 HI NDF 2

07H

.57 07H 07H

.610 NPSNM 111 HI

++..

+..

+-

+---+-+---+

÷......

÷-

+

93 93 105 105 105 105 105

.24 122 3.80 173 2.86 173 I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENOT PDIA PTYPE CAL LI S- -

+

- - -- +

+

+-

Tubes: 10 Records: 34 ST Max 1

SG-B HOT LEG APPENDIX 12.8 + POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X 127 TUBE ON HL APPENDIX 12.8 a 49 PLUGGED TUBE 10 105 100 95 90 85 80 75 70 o00C0O000 O000,0000 65 60 oP000aP0 55 50 45 40 35 q}OOOO)OOOOPOOOO POOCOOdOOOD 0

0 0

0 0

30 25 20 15 10 1311 1 O0 5

-0j:

45 40 35 25

.X...

.0

.00..

31

00.

X.X X a

-00 00

.4.

L.

° 0

M O.-

.00(

I

, 00

..*o~~

.0

..0 Go0.......

00....

0_

0()

0

000, T....

T 0

lO0..

0 0

0 0...

100...O 0..

X oo xX X x0

::: ::: :::x...

X

...i o.o.......

0 o

0 E)2 2

" T "

e

0.

0

.C i o M

X X X XXO0 000 C 00001 0

: ? :

o o...........

.0....

o_

XXXX :

0o 0XXXX:....

TI T : T T *

  • C *

.... 1

...0...,

x.... I.........

0

..! o 000

.... i x x..

.0 o....

o o....

0

..... x x.... !XXooo.

ý..::: *I::::::

.o::

I......

.. 0.............

0::

0000....

000:

o T0..T.

o o

: : ? : :

........ T......

00=

= = = === = = = = = === = = = = = =

:: : : : ! : : : : : : t :: t : : :

35 30 25 45 15 10 15 10 5

0...

0...

0***

0000 10o 1051o009poooo5 oooo0 850oooooooo7ooo7oooooo oooo6 60000 05 5Poo 4

4OO5OOOOO 3O000CpO000 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30

)000090000900009000090000OO 25 20 15 10 5

Westinghouse Electric Company LLC - ST Max 10/22/2009 20:22:57

SG -

B HOT LEG APPENDIIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2RI4 COE 20091001 10/22/2009 13:41:21

+----+----.----..

÷----+--------

+-

+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----..

+-+---------+-

+-+

11 36 NDD TEC TEH

.610 ZBAZC 53 HI 11 36 NOD 07H 07H

.610 NPSNM 113 HI 12 36 NDD TEC TEH

.610 ZBAZC 53 HI 12 36 NDD 07H 07H

.610 NPSNM 113 HI 13 36 NOD TEC TEH

.610 ZBAZC 53 HI 13 36 NOD 07H 07H

.610 NPSNM 113 HI 14 36 NDD TEC TEH

.610 ZBAZC 53 HI 14 36 NOD 07H 07H

.610 NPSNM 113 HI 15 36 NOD TEC TEH

.610 ZBAZC 53 HI 15 36 NOD 07H 07H

.610 NPSNM 113 HI 11 37 NOD TSH TSH

.610 NPSNM 3

HI 11 37 NOD TEC TEH

.610 ZBAZC 53 HI 11 37 NOD 07H 07H

.610 NPSNM 111 HI 12 37 NDD TSH TSH

.610 NPSNM 3

HI 12 37 NOD TEC TEH

.610 ZBAZC 55 HI 12 37 NOD 07H 07H

.610 NPSNM 111 HI 13 37 NOD TSH TSH

.610 NPSNM 3

HI 13 37 NOD TEC TEH

.610 ZBAZC 55 HI 13 37 NDD 07H 07H

.610 NPSNM 111 HI 14 37 NDD TSH TSH

.610 NPSNM 3

HI 14 37 2.16 180 DNG P1 07C 2.12 TEC TEH

.610 ZBAZC 55 HI 14 37 3.93 180 DNG P1 07C 3.66 TEC TEH

.610 ZBAZC 55 HI 14 37 2.87 180 0NG P1 07C 6.76 TEC TEH

.610 ZBAZC 55 HI 14 37 2.76 181 0NG P1 07C 21.25 TEC TEH

.610 ZBAZC 55 HI 14 37 2.64 180 DNG P1 07C 27.44 TEC TEH

.610 ZBAZC 55 HI 14 37 NDD 07H 07H

.610 NPSNM 111 HI 15 37 NOD TSH TSH

.610 NPSNM 3

HI 15 37 NOD TEC TEH

.610 ZBAZC 55 HI 15 37 NOD 07H 07H

.610 NPSNM 111 HI 11 38 NDD TSH TSH

.610 NPSNM 1

HI 11 38 NOD TEC TEH

.610 ZBAZC 53 HI 11 38 NOD 07H 07H

.610 NPSNM 113 HI 12 38 NDD TSH TSH

.610 NPSNM 1

HI 12 38 NDD TEC TEH

.610 ZBAZC 55 HI 12 38 NOD 07H 07H

.610 NPSNM 113 HI 13 38 NOD TSH TSH

.610 NPSNM 1

HI 13 38

.62 170 DFI 1

05H 34.98 TEC TEH

.610 ZBAZC 53 HI 13 38

.20 128 DFS 1

08C 3.52 TEC TEH

.610 ZBAZC 53 HI 13 38 TBP 2

07H 07H

.610 NPSNM 113 HI 13 38

.10 88 SVI P4 07H

-. 70 07H 07H

.610 NPSNM 113 HI 13 38

.15 89 PCT 18 2

07H

-. 70 05H 07H

.610 NPSNM 113 HI 14 38 NOD TSH TSH

.610 NPSNM 1

HI 14 38 2.92 80 MBM 6

01H 12.79 TEC TEH

.610 ZBAZC 53 HI 14 38

.29 43 DFS 1

09C 29.04 TEC TEH

.610 ZBAZC 53 HI 14 38 NDD 07H 07H

.610 NPSNM 113 HI 15 38 NOD TSH TSH

.610 NPSNM 1

HI 15 38 NOD TEC TEH

.610 ZBAZC 53 HI 15 38 NOD 07H 07H

.610 NPSNM 113 HI I11 39

.67 165 DFS 1

09H 4.13 TEC TEH

.610 ZBAZ 59 HI 11 39

.44 155 DFS 1

09H 39.35 TEC TEH

.610 ZBAZC 59 HI

+..

+.....

+------------+

+----+-

+-

+----

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----+.----+----...---------------+

+

1 ST Max

SG -

B HOT LEG APPENDIIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2RI4 CDE 20091001 10/22/2009 13:41:21

+----+----.----+----+----+

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----.----.----+

+----

+-

11 39 NOD 07H 07H

.610 NPSNM 111 HI 12 39 NOD TEC TEH

.610 ZBAZC 55 HI 12 39 NOD 07H 07H

.610 NPSNM 111 HI 13 39 NDD TEC TEH

.610 ZBAZC 55 HI 13 39 NDD 07H 07H

.610 NPSNM 111 HI 14 39 NOD TEC TEH

.610 ZBAZC 55 HI 14 39 NOD 07H 07H

.610 NPSNM 111 HI 15 39 NDD TEC TEH

.610 ZBAZC 55 HI 15 39 NDD 07H 07H

.610 NPSNM 111 HI 11 40 2.05 75 MBM 6

09H 8.24 TEC TEH

.610 ZBAZC 57 HI 11 40 NOD 07H 07H

.610 NPSNM 113 HI 12 40 NDD TEC TEH

.610 ZBAZC 57 HI 12 40 NDD 07H 07H

.610 NPSNM 113 HI 13 40 NOD TEC TEH

.610 ZBAZC 57 HI 13 40 NOD 07H 07H

.610 NPSNM 113 HI 14 40 NOD TEC TEH

.610 ZBAZC 57 HI 14 40 NOD 07H 07H

.610 NPSNM 113 HI 15 40 NDD TEC TEH

.610 ZBAZC 57 HI 15 40 NOD 07H 07H

.610 NPSNM 113 HI 28 54 2.51 182 DNG P1 TSH 20.24 TEC TEH

.610 ZBAZC 61 HI 28 54 NOD 07H 07H

.610 NPSNM 113 HI 29 54 NOD TEC TEH

.610 ZBAZC 61 HI 29 54 NOD 07H 07H

.610 NPSNM 113 HI 30 54 NDD TEC TEH

.610 ZBAZC 61 HI 30 54 NDD 07H 07H

.610 NPSNM 113 HI 31 54 NOD TEC TEH

.610 ZBAZC 61 HI 31 54 NOD 07H 07H

.610 NPSNM 113 HI 32 54 NDD TEC TEH

.610 ZBAZC 61 HI 32 54 NDD 07H 07H

.610 NPSNM 113 HI 28 55 NOD TSH TSH

.610 NPSNM 7

HI 28 55 NOD TEC TEH

.610 ZBAZC 63 HI 28 55 NOD 07H 07H

.610 NPSNM 111 HI 29 55 NDD TSH TSH

.610 NPSNM 7

HI 29 55 NOD TEC TEH

.610 ZBAZC 63 HI 29 55 NOD 07H 07H

.610 NPSNM 111 HI 30 55 NDF 2

TSH

-2.60 TSH TSH

.610 NPSNM 7

HI 30 55 NOD TEC TEH

.610 ZBAZC 63 HI 30 55 NOD 07H 07H

.610 NPSNM 111 HI 31 55 NDF 2

TSH

-2.75 TSH TSH

.610 NPSNM 7

HI 31 55 NOD TEC TEH

.610 ZBAZC 63 HI 1 31 55 NDD 07H 07H

.610 NPSNM 111 HI I 32 55 NOD TSH TSH

.610 NPSNM 7

HI I 32 55 NOD TEC TEH

.610 ZBAZC 63 HI I 32 55 NOD 07H 07H

.610 NPSNM 111 HI 1 28 56 NDF 2

TSH

-5.15 TSH TSH

.610 NPSNM 5

HI

+--------+

+-----

+-......"

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----.------------+----

+--------

+-.-........

2 ST Max

SG -

B HOT LEG APPENDIIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:41:21

+----...

+----

+---

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----.----

+--------+----+-

+----

28 56 NDF 2

TSH

-3.04 TSH TSH

.610 NPSNM 5

HI 28 56 NOD TEC TEH

.610 ZBAZC 61 HI 28 56 NDD 07H 07H

.610 NPSNM 111 HI 29 56 NDD TSH TSH

.610 NPSNM 5

HI 29 56 NOD TEC TEH

.610 ZBAZC 63 HI 29 56 NOD 07H 07H

.610 NPSNM 111 HI 30 56 NDD TSH TSH

.610 NPSNM 5

HI 30 56

.16 56 DSI P1 07H

-. 63 TEC TEH

.610 ZBAZC 61 HI 30 56 TBP 2

07H 07H

.610 NPSNM 111 HI 30 56

.10 76 SVI P4 07H

-. 77 07H 07H

.610 NPSNM 111 HI 30 56

.11 281 PCT 15 PI 07H

-. 74 07H 07H

.610 NPSNM 111 HI 31 56 NDD TSH TSH

.610 NPSNM 5

HI 31 56 NDD TEC TEH

.610 ZBAZC 63 HI 31 56 NDD 07H 07H

.610 NPSNM 111 HI 32 56 NOD TSH TSH

.610 NPSNM 5

HI 32 56 NOD TEC TEH

.610 ZBAZC 61 HI 32 56 NDD 07H 07H

.610 NPSNM 111 HI 28 59 NDD TEC TEH

.610 ZBAZC 61 HI 28 59 NDD 07H 07H

.610 NPSNM 113 HI 29 59 NOD TEC TEH

.610 ZBAZC 61 HI 29 59 NOD 07H 07H

.610 NPSNM 113 HI 30 59 NDD TEC TEH

.610 ZBAZC 61 HI 30 59 NDD 07H 07H

.610 NPSNM 113 HI 31 59 NDD TEC TEH

.610 ZBAZC 61 HI 31 59 NOD 07H 07H

.610 NPSNM 113 HI 32 59 3.53 183 ONG P1 03H 11.44 TEC TEH

.610 ZBAZC 61 HI 32 59 NDD 07H 07H

.610 NPSNM 113 HI 39 59 NDD TSH TSH

.610 NPSNM 21 HI 39 59 NDD TEC TEH

.610 ZBAZC 61 HI 40 59 NOD TSH TSH

.610 NPSNM 21 HI 40 59 1.65 0

PCT 22 P2 AVI

.00 TEC TEH

.610 ZBAZC 61 HI 40 59 1.80 0

PCT 23 P2 AV2

.00 TEC TEH

.610 ZBAZC 61 HI 40 59 3.18 0

PCT 31 P2 AV3

.00 TEC TEH

.610 ZBAZC 61 HI 40 59 1.25 0

PCT 19 P2 AV4

.00 TEC TEH

.610 ZBAZC 61 HI 41 59 NOD 03C 03C

.610 NPSNM 4

CI 41 59 NOD 02C 02C

.610 NPSNM 4

CI 41 59 NMD TSH TSH

.610 NPSNM 21 H

I41 59 NOD TEC TEH

.610 ZBAZC 61 HI 42 59 NDD TSH TSH

.610 NPSNM 21 HI 42 59 NDD TEC TEH

.610 ZBAZC 61 HI 43 59 NDD TSH TSH

.610 NPSNM 21 HI 43 59 NOD TEC TEH

.610 ZBAZC 61 HI 44 59 NDD 02C 02C

.610 NPSNM 4

CI 44 59 NDD 03C 03C

.610 NPSNM 4

CI 44 59 NDD TSH TSH

.610 NPSNM 21 HI 44 59 2.39 76 MBM 6

10H 11.99 TEC TEH

.610 ZBAZC 61 HI 44 59 2.49 180 ONT P1 AV2

.13 TEC TEH

.610 ZBAZC 61 HI 28 60 NOD TEC TEH

.610 ZBAZC 63 HI 28 60 NOD 07H 07H

.610 NPSNM 111 HI

+----+----.----+----.----+

+----+-

+-

+---

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----------------.----+----....+--+----

+-----+----+-

+-

+---

3 ST Max

SG - B HOT LEG APPENDIIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:41:21

+----.--------.----.----.----

+----+----+--

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷..

+-..

+----+--....----+

+.

+

-.4.-..÷...

29 60 NDD TEC TEH

.610 ZBAZC 63 HI 29 60 NOD 07H 07H

.610 NPSNM 111 HI 30 60 NOD TEC TEH

.610 ZBAZC 63 HI 30 60 NDD 07H 07H

.610 NPSNM 111 HI 31 60 2.52 70 MBM 6

05H 26.93 TEC TEH

.610 ZBAZC 63 HI 31 60 NOD 07H 07H

.610 NPSNM 111 HI 32 60 NDD TEC TEH

.610 ZBAZC 63 HI 32 60 NDD 07H 07H

.610 NPSNM 111 HI 39 60 NOD TSH TSH

.610 NPSNM 23 HI 39 60 NOD TEC TEH

.610 ZBAZC 63 HI 40 60 NDD TSH TSH

.610 NPSNM 23 HI 40 60 NDD TEC TEH

.610 ZBAZC 63 HI 41 60 NOD TSH TSH

.610 NPSNM 23 HI 41 60 NOD TEC TEH

.610 ZBAZC 63 HI 42 60 NDD TSH TSH

.610 NPSNM 23 HI 42 60 NDD TEC TEH

.610 ZBAZC 63 HI 43 60 NDD TSH TSH

.610 NPSNM 23 HI 43 60 NOD TEC TEH

.610 ZBAZC 63 HI 44 60 NOD TSH TSH

.610 NPSNM 23 HI 44 60 4.00 74 MBM 6

07C 29.02 TEC TEH

.610 ZBAZC 63 HI 41 61 NDD TSH TSH

.610 NPSNM 17 HI 41 61 NDD TEC TEH

.610 ZBAZC 61 HI 42 61 NOD TSH TSH

.610 NPSNM 17 HI 42 61 NOD TEC TEH

.610 ZBAZC 61 HI 19 63 NDD TEC TEH

.610 ZBAZC 65 HI 19 63 NDD 05H 05H

.610 NPSNM 11 HI 20 63 NOD TEC TEH

.610 ZBAZC 65 HI 20 63 NOD 05H 05H

.610 NPSNM 111 HI 21 63 NDD TEC TEH

.610 ZBAZC 65 HI 21 63 NDD 05H 05H

.610 NPSNM 111 HI 24 63 NOD TEC TEH

.610 ZBAZC 61 HI 24 63 NOD 05H 05H

.610 NPSNM 111 HI 25 63 NDD TEC TEH

.610 ZBAZC 63 HI 25 63 NDD 05H 05H

.610 NPSNM 113 HI 39 63 NDD TSH TSH

.610 NPSNM 21 HI 39 63 NOD TEC TEH

.610 ZBAZC 63 HI 40 63 NOD TSH TSH

.610 NPSNM 21 HI 40 63 NDD TEC TEH

.610 ZBAZC 63 HI 41 63 NDD TSH TSH

.610 NPSNM 21 HI 41 63 NOD TEC TEH

.610 ZBAZC 63 HI 42 63 NOD TSH TSH

.610 NPSNM 21 HI 42 63 NOD TEC TEH

.610 ZBAZC 63 HI 43 63 NDD TSH TSH

.610 NPSNM 21 HI

÷

÷

+

+----------.----.----+----+----+----+--..

+.----+----+


+---.---

+-.....--÷ I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷

--- -÷

+

+

-+---

÷

+-

÷ 4

ST Max

SG -

B HOT LEG APPENDIIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:41:21

+----------------

+-

+

+

-+......-+..-.+..-"

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL Li

+----.----.----.----+

+-

+--

+.......-.....+......4--

43 63 NOD TEC TEH

.610 ZBAZC 65 HII 44 63 NDD TSH TSH

.610 NPSNM 21 HI 44 63 NOD TEC TEH

.610 ZBAZC 65 HI I'

19 64 NOD TEC TEH

.610 ZBAZC 67 HI 19 64 NOD 05H 05H

.610 NPSNM 113.

HII 20 64 NDD TEC TEH

.610 ZBAZC 67 HI 20 64 NOD 05H 05H

.610 NPSNM 113 HI 21 64 NOD TEC TEH

.610 ZBAZC 67 HI 21 64 NOD 05H 05H

.610 NPSNM 113 HI 24 64 NOD TEC TEH

.610 ZBAZC 61 HI 24 64 NDD 05H 05H

.610 NPSNM 111 HI 25 64 NOD TEC TEH

.610 ZBAZC 63 HI 25 64 NOD 05H 05H

.610 NPSNM 113 HI 17 65 NOD TEC TEH

.610 ZBAZC 65 HI 17 65 NDD 05H 05H

.610 NPSNM 111 HI 18 65 NOD TEC TEH

.610 ZBAZC 65 HI 18 65 NOD 05H 05H

.610 NPSNM 111 HI 19 65 NOD TEC TEH

.610 ZBAZC 65 HI 19 65 NOD 05H 05H

.610 NPSNM 111 HI 20 65 NDD TEC TEH

.610 ZBAZC 65 HI 20 65 NDD 05H 05H

.610 NPSNM 111 HI 21 65

.22 51 DSI P1 05H

-. 63 TEC TEH

.610 ZBAZC 65 HI 21 65 TBP 2

05H 05H

.610 NPSNM 111 HI 21 65

.28 263 SVI P4 05H

-. 64 05H 05H

.610 NPSNM 111 HI 21 65

.37 264 PCT 34 P1 05H

-. 63 05H 05H

.610 NPSNM 111 HI 24 65 NDD TEC TEH

.610 ZBAZC 61 HI 24 65 NDD 05H 05H

.610 NPSNM 111 HI 25 65 NOD TEC TEH

.610 ZBAZC 63 HI 25 65 NOD 05H 05H

.610 NPSNM 113 HI 17 66 NOD TEC TEH

.610 ZBAZC 67 HI 17 66 NDD 05H 05H

.610 NPSNM 113 HI 18 66 NOD TEC TEH

.610 ZBAZC 67 HI 18 66 NOD 05H 05H

.610 NPSNM 113 HI 19 66 NOD TEC TEH

.610 ZBAZC 67 HI 19 66 NOD 05H 05H

.610 NPSNM 113 HI 20 66 NDD TEC TEH

.610 ZBAZC 67 HI 20 66 NDD 05H 05H

.610 NPSNM 113 HI 21 66 NOD TEC TEH

.610 ZBAZC 67 HI 21 66 NOD 05H 05H

.610 NPSNM 113 HI 24 66 NOD TEC TEH

.610 ZBAZC 61 HI 24 66 NOD 05H 05H

.610 NPSNM 111 HI i

25 66 NDD TEC TEH

.610 ZBAZC 63 HI i

25 66 NDD 05H 05H

.610 NPSNM 113 HI I

17 67 NOD TSH TSH

.610 NPSNM 7

HI

+----+----+----+

+----...+-----

+-÷....

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+....

4

+-4

---+----

+----+----

+-

+---....

4 5

ST Max

SG - B HOT LEG APPENDIIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2RI4 CDE 20091001 10/22/2009 13:41:21

+-----------------------+----...+

+----....+

+

-+-+....

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Ll

  • -+---------+---..----+----.----...+..-----------+----.+-

-+-+....

17 67 NOD TEC TEH

.610 ZBAZC 65 HI 17 67 NOD 05H 05H

.610 NPSNM 111 HI 18 67 NOD TSH TSH

.610 NPSNM 7

Hi 18 67 NOD TEC TEH

.610 ZBAZC 65 HI 18 67 NDD 05H.05H

.610 NPSNM 111 HI 19 67 NOD TSH TSH

.610 NPSNM 7

HI 19 67

.41 158 DFI 1

05H

-. 88 TEC TEH

.610 ZBAZC 65 HI 19 67 TBP 2

05H 05H

.610 NPSNM 111 HI 19 67

.15 92 SVI P4 05H

-. 79 05H 05H

.610 NPSNM 111 HI 19 67

.17 94 PCT 19 2

05H

-. 78 05H 05H

.610 NPSNM 111 HI 20 67 NOD 02C 02C

.610 NPSNM 4

CI 20 67 NDD TSH TSH

.610 NPSNM 5

HI 20 67 NDD TEC TEH

.610 ZBAZC 65 HI 20 67 NOD 05H 05H

.610 NPSNM 111 HII 21 67 NDD 02C 02C

.610 NPSNM 4

CI 21 67 NDD TSH TSH

.610 NPSNM 5

HI 21 67 3.95 81 MBM 6 09H 20.48 TEC TEH

.610 ZBAZC 65 HI 21 67 NOD 05H 05H

.610 NPSNM 111 HI 24 67 NDD 02C 02C

.610 NPSNM 4

CI 24 67 NDD TSH TSH

.610 NPSNM 7

HI 24 67 NOD TEC TEH

.610 ZBAZC 61 HI 24 67 NOD 05H 05H

.610 NPSNM 111 HI 25 67 NDD 02C 02C

.610 NPSNM 4

CI 25 67 NOD TSH TSH

.610 NPSNM 7

HI 25 67

.17 150 DFS 1 06C 16.26 TEC TEH

.610 ZBAZC 63 HI 25 67 NOD 05H 05H

.610 NPSNM 113 HI 17 68 NDD TSH TSH

.610 NPSNM 5

HI 17 68 NOD TEC TEH

.610 ZBAZC 67 HI 17 68 NOD 05H 05H

.610 NPSNM 113 HI 18 68 NOD TSH TSH

.610 NPSNM 5

HI 18 68 NOD TEC TEH

.610 ZBAZC 67 HI 18 68 NOD 05H 05H

.610 NPSNM 113 HI 19 68 NDD TSH TSH

.610 NPSNM 5

Hi 19 68 NOD TEC TEH

.610 ZBAZC 67 HI 19 68 NOD 05H 05H

.610 NPSNM 113 HI 20 68 NDD TSH TSH

.610 NPSNM 5

HI 20 68 NDD 02C 02C

.610 NPSNM 6

CI 20 68 NOD TEC TEH

.610 ZBAZC 67 HI 20 68 NOD 05H 05H

.610 NPSNM 113 HI 21 68 NDD 02C 02C

.610 NPSNM 4

CI 21 68 NOD TSH TSH

.610 NPSNM 5

HI 21 68 NOD TEC TEH

.610 ZBAZC 67 HI 21 68 NOD 05H 05H

.610 NPSNM 113 HI 24 68 NDD 02C 02C

.610 NPSNM 4

CI 24 68 NOD TSH TSH

.610 NPSNM 5

HI 24 68 NOD TEC TEH

.610 ZBAZC 61 HI 24 68 NOD 05H 05H

.610 NPSNM 111 HI 1 25 68 NDD TSH TSH

.610 NPSNM 5

HI 25 68 NOD 02C 02C

.610 NPSNM 6

CI 25 68 NOD TEC TEH

.610 ZBAZC 63 HI 25 68 NDD 05H 05H

.610 NPSNM 113 HI

+------

-+..----+--....-------+---

+

-+

+--

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+...+....

-+-

+


+--.---

6 ST Max

SG -

B HOT LEG APPENDIIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:41:21

+-----

+

+--------

+-

+

+-.-...

I ROW COL VOLTS DEG IND PER CHN LOON INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+

+----........------

+

+.....

17 69 NOD TEC TEH

.610 ZBAZC 65 HI 17 69 NOD 05H 05H

.610 NPSNM 111 HI 18 69 NDD TEC TEH

.610 ZBAZC 65 HI 18 69 NOD 05H 05H

.610 NPSNM 111 Hi 19 69 NOD TEC TEH

.610 ZBAZC 65 HI 19 69 NOD 05H 05H

.610 NPSNM 111 HI 20 69 NOD 02C 02C

.610 NPSNM 6

CI 20 69 NOD TEC TEH

.610 ZBAZC 65 HI 20 69 NOD 05H 05H

.610 NPSNM 111 HI 21 69 NOD 02C 02C

.610 NPSNM 4

CI 21 69 NDD TEC TEH

.610 ZBAZC 65 HI 21 69 NOD 05H 05H

.610 NPSNM 113 HI 24 69 NDF 2

02C

.36 02C 02C

.610 NPSNM 4

CI 24 69

.34 143 DSS P1 02C

.36 TEC TEH

.610 ZBAZC 61 HI 24 69 NDD 05H 05H

.610 NPSNM 111 HI 25 69 NOD 02C 02C

.610 NPSNM 6

C1 25 69 NOD TEC TEH

.610 ZBAZC 63 HI 25 69 NOD 05H 05H

.610 NPSNM 113 HI 20 70 NDD 02C 02C

.610 NPSNM 6

CI 20 70 NDD TEC TEH

.610 ZBAZC 67 HI 20 70 NDD 05H 05H

.610 NPSNM 111 HI 21 70 NOD TSC TSC

.610 NPSNM 4

CI 21 70 NOD 02C 02C

.610 NPSNM 4

CI 21 70 NOD TEC TEH

.610 ZBAZC 67 HI 21 70 NDD 05H 05H

.610 NPSNM 113 HI 22 70 NOD 020 020

.610 NPSNM 4

CI 22 70 NOD TSC TSC

.610 NPSNM 4

CI 22 70 NOD TEC TEH

.610 ZBAZC 67 HI 22 70 NOD 05H 05H

.610 NPSNM 113 Hf 23 70 NDD TSC TSC

.610 NPSNM 4

CI 23 70 NOD 02C 02C

.610 NPSNM 4

CI 23 70 NOD TEC TEH

.610 ZBAZC 67 HI 23 70 NOD 05H 05H

.610 NPSNM 113 HI 24 70 NDD TSC TSC

.610 NPSNM 4

CI 24 70 NDD 02C 02C

.610 NPSNM 4

CI 24 70 NOD TEC TEH

.610 ZBAZC 61 HI 24 70 NOD 05H 05H

.610 NPSNM 111 HI 25 70 NDD 02C 02C

.610 NPSNM 4

CO 25 70 NDD TSC TSC

.610 NPSNM 4

CO 25 70 NDD TEC TEH

.610 ZBAZC 63 HI 25 70 NOD 05H 05H

.610 NPSNM 113 HI 20 71 NOD TSH TSH

.610 NPSNM 5

HI 20 71 NOD 02C 02C

.610 NPSNM 6

CI 20 71 NDD TEC TEH

.610 ZBAZC 65 HI 20 71 NDD 05H 05H

.610 NPSNM 111 HI 21 71 NOD TSC TSC

.610 NPSNM 6

CI 21 71 NOD 02C 02C

.610 NPSNM 6

Cf 21 71 NOD TEC TEH

.610 ZBAZC 65 Hf 21 71 NOD 05H 05H

.610 NPSNM 111 Hf 22 71 NDD TSC TSC

.610 NPSNM 6

Cf

+----+----+-----------+-----+-----+-----+

+----+-----+

+--------

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----+------------+.

+----+-.

+-

+---

7 ST Max

SG - B HOT LEG APPENDIIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 COE 20091001 10/22/2009 13:41:21 S-.

+

+-

+

+-----

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+....

÷

÷....

+-

+

+

+

÷ 22 71 NDD 02C 02C

.610 NPSNM 6 CI 22 71 NOD TEC TEH

.610 ZBAZC 65 HI 22 71 NOD 05H 05H

.610 NPSNM 111 HI 23 71 NDD 02C 02C

.610 NPSNM 6

CI 23 71 NDD TSC TSC

.610 NPSNM 6 CI 23 71 NOD TEC TEH

.610 ZBAZC 65 HI 23 71 NOD 05H 05H

.610 NPSNM 111 HI 24 71 NDD TSC TSC

.610 NPSNM 6

CI 24 71 NDD 02C 02C

.610 NPSNM 6

CI 24 71 NOD TEC TEH

.610 ZBAZC 61 HI 24 71 NOD 05H 05H

.610 NPSNM 111 HI 25 71 NOD 02C 02C

.610 NPSNM 6

CI 25 71 NDD TSC TSC

.610 NPSNM 6

CI 25 71 NDD TEC TEH

.610 ZBAZC 61 HI 25 71 NOD 05H 05H

.610 NPSNM 113 HI

+-.---..-------------+--

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷....

÷....

÷

+----+-

+-÷---

4*..--

+

÷

÷ Tubes: 127 Records: 347 8

ST Max

SG-B COLD LEG APPENDIX 12.8 + POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X 85 TUBE ON CL APPENDIX 12.8 a 49 PLUGGED TUBE 110 105 100 95 90 85 80 75 70 SOOO,00O0009*O0O0OO00O 13113....

j...

65 60 55 50 45 to0000o o0o0 oooooooo00o XAXXx.........

o XýXX 40

  • 0000 35 30 25 20 15 10

,pOOOa 00001DD

... -00D3 5

45 35 25 20 15 13 1310C

... 0 x~ XXX 1313 no._

_÷'

I o

.am D.

0.

E)

G E).0 m-7....

00 0

0 0

0 0

DO. -

O......

Xx X o

X T o...

.. 0 0.......

0 t

...0 0 0 0

... 0

.0

..0 e e v e &

- e e

00 OO....

O0...

0..

OO 00.o 0

o o..""'........

00 00 0

f

.. 0 00 e.,°o0 e.°° oo0 00o I.

° i: :......

0...

.... 0 0.... I.... T....

0 0 0

.... XXXX xxx 0000()

00....

o oo...:0 00,:

... *X

=...x x 0

T..

1v-f X

X 0

=

00

',........ X XX o

)0 0

00 0..

0 00 0

ii

!! i ii

: I ! ! i i : !.......

...0:

°..............

0.0...

i~

................o o..

T o..... 0

.X:::0 00......I...

45 35 30 25 15 10 5

5 0e..

0...

0000

.... I

I:***

105

10.

0 9

90 lie 105 100 95 90

-X 515oo 0 45Doooo ooo0 35T3025*o2oooo0 1

0.1 0

0000 55 50 45 40 35 30 25 20 15 1@

5 OOOO*OOOOooooO)OOOýO000O00(OOO 85 80 75 70 65 60 Westinghouse Electdc Company LLC - ST Max 10/2212009 20:22:45

SG - B COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:42:41

+..

+.....-----------.----.-.------.----.----+----

+ -

+-+

-+

ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷....-----------+----.----.----+----.-

+-÷

+----

+-÷....

÷ 44 52 NDD 03C 03C

.610 NPSNM 6

CI 44 52 NDD TEC TEH

.610 ZBAZC 61 HII 45 52 NDD 03C 03C

.610 NPSNM 6

Cl 45 52

.14 74 DFS 1

01H 17.55 TEC TEH

.610 ZBAZC 61 HII 46 52 NDD 03C 03C

.610 NPSNM 6

CI 46 52 2.53 185 DNG P1 09C 7.37 TEC TEH

.610 ZBAZC 61 HI 47 52 NDF 2

TSH

-4.31 TSH TSH

.610 NPSNM 5

HI 47 52 NDD 03C 03C

.610 NPSNM 6

Cl 47 52 NDD TEC TEH

.610 ZBAZC 61 HI 48 52 NOD 03C 03C

.610 NPSNM 6

CI 48 52 NOD TEC TEH

.610 ZBAZC 61 HI 4

53 NOD 02C 02C

.610 NPSNM 2

CI 4

53 NOD 11C TEC

.610 ZBAZC 8

CI 4

53 NOD 11C TEH

.590 SBUCC 105 HI 5

53 NOD 02C 02C

.610 NPSNM 2

CI 5

53 NDD TEC TEH

.610 ZBAZC 33 HI 43 53 NOD 02C 02C

.610 NPSNM 6

CI 43 53 NOD TEC TEH

.610 ZBAZC 63 HI 44 53 NOD 03C 03C

.610 NPSNM 6

CI 44 53 NOD TEC TEH

.610 ZBAZC 63 HI 45 53 NOD 03C 03C

.610 NPSNM 4

CI 45 53 NOD TEC TEH

.610 ZBAZC 63 HI 46 53 NOD 03C 03C

.610 NPSNM 4

CI 46 53

.52 100 DFS 3

AV4 30.83 TEC TEH

.610 ZBAZC 63 HI 46 53 1.32 149 DSS P1 liC

-. 46 TEC TEH

.610 ZBAZC 63 HI 46 53 4.98 172 DNT P1 liC

.06 TEC TEH

.610 ZBAZC 63 HI 47 53 NOD 03C 03C

.610 NPSNM 4

CI 47 53 NOD TEC TEH

.610 ZBAZC 63 HI 48 53 NOD 03C 03C

.610 NPSNM 4

CI 48 53 NOD TEC TEH

.610 ZBAZC 63 HI 4

54 NOD 02C 02C

.610 NPSNM 2

CI 4

54 NDD lC TEC

.610 ZBAZC 8

CI 4

54 NOD llC TEH

.590 SBUCC 105 HI 5

54 NOD 02C 02C

.610 NPSNM 2

CI 5

54 NDD TEC TEH

.610 ZBAZC 35 HI 20 54 NOD 02C 02C

.610 NPSNM 4

CI 20 54 2.40 184 ONG P1 09H 11.35 TEC TEH

.610 ZBAZC 33 HI 44 54 NOD 03C 03C

.610 NPSNM 4

CI 44 54 NOD TEC TEH

.610 ZBAZC 61 HI 45 54 NOD 03C 03C

.610 NPSNM 4

CI 45 54

.29 153 DFS 1

09C 33.39 TEC TEH

.610 ZBAZC 61 HI 46 54 NDF 2

03C

-. 32 03C 03C

.610 NPSNM 6

CI 46 54

.51 129 DSS P1 liC

-. 56 TEC TEH

.610 ZBAZC 61 HI 46 54

.19 94 DSS P1 03C

-. 32 TEC TEH

.610 ZBAZC 61 HI 47 54 NOD 03C 03C

.610 NPSNM 6

CI 47 54 NOD TEC TEH

.610 ZBAZC 61 HI

+

+-----+-----+-----+-----+-----+

+----+-----+

+--------

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

-÷-----------.+----+----+----.----+----

+--------

+....--

1 ST Max

SG -

B COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2RI4 CDE 20091001 10/22/2009 13:42:41

÷----

÷

÷÷

-÷-

-4

-÷-

"÷ I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷--

+----.----.----+----+----+..

+----....+-----

÷ 48 54 NDD 03C 03C

.610 NPSNM 6

CI 48 54 2.31 182 DNT P1 AV3

-. 10 TEC TEH

.610 ZBAZC 61 HI 44 55 NDD 03C 03C

.610 NPSNM 4

Cl 44 55 NDD TSH TSH

.610 NPSNM 5

HI 44 55 NDD TEC TEH

.610 ZBAZC 63 HI 45 55 NDD 03C 03C

.610 NPSNM 4

Cl 45 55 NDD TSH TSH

.610 NPSNM 5

HI 45 55 NDD TEC TEH

.610 ZBAZC 63 HI 46 55 NDD TSH TSH

.610 NPSNM 5

HI 46 55 NDD 03C 03C

.610 NPSNM 6

CI 46 55 NDD TEC TEH

.610 ZBAZC 63 HI 47 55 NDD TSH TSH

.610 NPSNM 5

HI 47 55 NDD 03C 03C

.610 NPSNM 6

CI 47 55 NDD TEC TEH

.610 ZBAZC 63 HI 48 55 NDD TSH TSH

.610 NPSNM 5

HI 48 55 NDD 02C 02C

.610 NPSNM 6

CI 48 55 NDD 03C 03C

.610 NPSNM 6

CI 48 55 2.54 184 DNT P1 AV1

.00 TEC TEH

.610 ZBAZC 63 HI 44 56 NDD 03C 03C

.610 NPSNM 4

CI 44 56 NDD TSH TSH

.610 NPSNM 7

HI 44 56 NDD TEC TEH

.610 ZBAZC 63 HI 45 56 NOD 03C 03C

.610 NPSNM 4

CI 45 56 NOD TSH TSH

.610 NPSNM 7

HI 45 56 NOD TEC TEH

.610 ZBAZC 63 HI 46 56 NOD 02C 02C

.610 NPSNM 4

CI 46 56 NOD 03C 03C

.610 NPSNM 4

CI 46 56 NDD TSH TSH

.610 NPSNM 7

HI 46 56 NOD TEC TEH

.610 ZBAZC 61 HI 47 56 NOD 03C 03C

.610 NPSNM 4

CI 47 56 NOD TSH TSH

.610 NPSNM 7

HI 47 56 NOD TEC TEH

.610 ZBAZC 61 HI 48 56 NOD 03C 03C

.610 NPSNM 4

CI 48 56 NOD TSH TSH

.610 NPSNM 7

HI 48 56

.56 65 INR 1

11H 3.20 TEC TEH

.610 ZBAZC 61 HI 12 58 NOD 02C 02C

.610 NPSNM 2

CI 12 58 NDD TEC TEH

.610 ZBAZC 93 HI 4

59 NDD 02C 02C

.610 NPSNM 2

CI 4

59 NOD 11C TEC

.610 ZBAZC 8

CI 4

59 NOD 1IC TEH

.590 SBUCC 105 HI 15 61 NOD 02C 02C

.610 NPSNM 2

CI 15 61 2.61 181 ONG P1 AV4 2.09 TEC TEH

.610 ZBAZC 89 HI 33 65 NDD 02C 02C

.610 NPSNM 6

CI 33 65 NOD TEC TEH

.610 ZBAZC 63 HI 20 67 NOD 02C 02C

.610 NPSNM 4

CI 20 67 NOD TSH TSH

.610 NPSNM 5

HI 20 67 NOD TEC TEH

.610 ZBAZC 65 HI 20 67 NOD 05H 05H

.610 NPSNM 111 HI 21 67 NDD 02C 02C

.610 NPSNM 4

CI

+-----+-----+-----+-----+-----+

+----+-----+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+---.......----...--+


+--

+...--÷ 2

ST Max

SG -

B COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2RI4 CDE 20091001 10/22/2009 13:42:41

÷-

-+

+....

.+

F----+ -

-4

+......

÷ I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL Ll S..÷

÷

+----+----+----.----+......----+----

+----.-----

+-÷....

÷ 21 67 NDD TSH TSH

.610 NPSNM 5

Hi 21 67 3.95 81 MBM 6

09H 20.48 TEC TEH

.610 ZBAZC 65 HI 21 67 NDD 05H 05H

.610 NPSNM 111 HI 24 67 NDD 02C 02C

.610 NPSNM 4

CI 24 67 NDD TSH TSH

.610 NPSNM 7

HI 24 67 NDD TEC TEH

.610 ZBAZC 61 HI 24 67 NDD 05H 05H

.610 NPSNM 111 HI 25 67 NDD 02C 02C

.610 NPSNM 4

CI 25 67 NDD TSH TSH

.610 NPSNM 7

HI 25 67

.17 150 DFS 1 06C 16.26 TEC TEH

.610 ZBAZC 63 HI 25 67 NDD 05H 05H

.610 NPSNM 113 HI 26 67 NDD 02C 02C

.610 NPSNM 4

CI 26 67 NDD TSH TSH

.610 NPSNM 7

HI 26 67 NDD TEC TEH

.610 ZBAZC 61 HI 20 68 NDD TSH TSH

.610 NPSNM 5

HI 20 68 NDD 02C 02C

.610 NPSNM 6

CI 20 68 NDD TEC TEH

.610 ZBAZC 67 Hl 20 68 NDD 05H 05H

.610 NPSNM 113 HI 21 68 NDD 02C 02C

.610 NPSNM 4

CI 21 68 NDD TSH TSH

.610 NPSNM 5

HI 21 68 NDD TEC TEH

.610 ZBAZC 67 HI 21 68 NDD 05H 05H

.610 NPSNM 113 HI 24 68 NDD 02C 02C

.610 NPSNM 4

CI 24 68 NDD TSH TSH

.610 NPSNM 5

HI 24 68 NDD TEC TEH

.610 ZBAZC 61 HI 24 68 NDD 05H 05H

.610 NPSNM 111 HI 25 68 NDD TSH TSH

.610 NPSNM 5

HI 25 68 NDD 02C 02C

.610 NPSNM 6

CI 25 68 NDD TEC TEH

.610 ZBAZC 63 HI 25 68 NDD 05H 05H

.610 NPSNM 113 HI 26 68 NDD 02C 02C

.610 NPSNM 4

CI 26 68 NDD TSH TSH

.610 NPSNM 5

HI 26 68 NDD TEC TEH

.610 ZBAZC 61 HI 20 69 NDD 02C 02C

.610 NPSNM 6

CI 20 69 NDD TEC TEH

.610 ZBAZC 65 HI 20 69 NDD 05H 05H

.610 NPSNM 111 HI 21 69 NDD 02C.02C

.610 NPSNM 4

CI 21 69 NDD TEC TEH

.610 ZBAZC 65 HI 21 69 NDD 05H 05H

.610 NPSNM 113 HI 24 69 NDF 2

02C

.36 02C 02C

.610 NPSNM 4

CI 24 69

.34 143 DSS P1 02C

.36 TEC TEH

.610 ZBAZC 61 HI 24 69 NDD 05H 05H

.610 NPSNM 111 HI 25 69 NDD 02C 02C

.610 NPSNM 6

CI 25 69 NDD TEC TEH

.610 ZBAZC 63 HI 25 69 NDD 05H 05H

.610 NPSNM 113 HI 26 69 NDD 02C 02C

.610 NPSNM 4

CI 26 69 NDD TEC TEH

.610 ZBAZC 61 HI 20 70 NDD 02C 02C

.610 NPSNM 6

CI 20 70 NDD TEC TEH

.610 ZBAZC 67 HI 20 70 NDD 05H 05H

.610 NPSNM 111 HI

+----+-----+-----+-----+------+----+

+-----+----+

+--------

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷....

÷

÷

+---

+-.....--

+

3 ST Max

SG -

B COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:42:41

÷....

÷

+--

+.-----+-----

+

-- +-....

+

+......

÷-

+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

- -+..."----------.----.--------+----+--------+

-+..----+-

+-

21 70 NDD TSC TSC

.610 NPSNM 4

CI 21 70 NDD 02C 02C

.610 NPSNM 4

C1 21 70 NDD TEC TEH

.610 ZBAZC 67 HI 21 70 NDD 05H 05H

.610 NPSNM 113 HI 22 70 NDD 02C 02C

.610 NPSNM 4

CI 22 70 NDD TSC TSC

.610 NPSNM 4

CI 22 70 NDD TEC TEH

.610 ZBAZC 67 HI 22 70 NDD 05H 05H

.610 NPSNM 113 HI 23 70 NDD TSC TSC

.610 NPSNM 4

C1 23 70 NDD 02C 02C

.610 NPSNM 4

CI 23 70 NDD TEC TEH

.610 ZBAZC 67 HI 23 70 NDD 05H 05H

.610 NPSNM 113 HI 24 70 NDD TSC TSC

.610 NPSNM 4

CI 24 70 NDD 02C 02C

.610 NPSNM 4

CI 24 70 NDD TEC TEH

.610 ZBAZC 61 HI 24 70 NDD 05H 05H

.610 NPSNM 111 HI 25 70 NDD 02C 02C

.610 NPSNM 4

CI 25 70 NDD TSC TSC

.610 NPSNM 4

CI 25 70 NDD TEC TEH

.610 ZBAZC 63 HI 25 70 NDD 05H 05H

.610 NPSNM 113 HII 26 70 NDD 02C 02C

.610 NPSNM 4

CI 26 70

.94 71 DSS P1 liC

.27 TEC TEH

.610 ZBAZC 63 HII 20 71 NDD TSH TSH

.610 NPSNM 5

HI 20 71 NDD 02C 02C

.610 NPSNM 6

CI 20 71 NDD TEC TEH

.610 ZBAZC 65 HI 20 71 NDD 05H 05H

.610 NPSNM 111 HI 21 71 NDD TSC TSC

.610 NPSNM 6

CI 21 71 NDD 02C 02C

.610 NPSNM 6

CI 21 71 NDD TEC TEH

.610 ZBAZC 65 HI 21 71 NDD 05H 05H

.610 NPSNM Ill HI 22 71 NDD TSC TSC

.610 NPSNM 6

CI 22 71 NDD 02C 02C

.610 NPSNM 6

CI 22 71 NDD TEC TEH

.610 ZBAZC 65 HI 22 71 NDD 05H 05H

.610 NPSNM 111 HI 23 71 NDD 02C 02C

.610 NPSNM 6

CI 23 71 NDD TSC TSC

.610 NPSNM 6

CI 23 71 NDD TEC TEH

.610 ZBAZC 65 HI 23 71 NDD 05H 05H

.610 NPSNM 111 HI 24 71 NDD TSC TSC

.610 NPSNM 6

CI 24 71 NDD 02C 02C

.610 NPSNM 6

CI 24 71 NDD TEC TEH

.610 ZBAZC 61 HI 24 71 NDD 05H 05H

.610 NPSNM 111 HI 25 71 NDD 02C 02C

.610 NPSNM 6

CI 25 71 NDD TSC TSC

.610 NPSNM 6

CI 25 71 NDD TEC TEH

.610 ZBAZC 61 HI 25 71 NDD 05H 05H

.610 NPSNM 113 HI 26 71 NDD 02C 02C

.610 NPSNM 6

CI 26 71 NDD TEC TEH

.610 ZBAZC 61 HI 21 72 NDD TSC TSC

.610 NPSNM 4

CI 21 72 3.16 74 MBM 6

08H 21.41 TEC TEH

.610 ZBAZC 67 HI 21 72 2.37 81 MBM 6

08H 28.23 TEC TEH

.610 ZBAZC 67 HI 21 72 3.04 69 MBM 6

09C 5.00 TEC TEH

.610 ZBAZC 67 HI

+--------+----+--------+---.

+---------------+-

+---

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

-+----+----.----+

+-----+

+--

4 ST Max

SG -

B COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:42:41 S....

+-----------+----.------------+-----+

+..----

+- -

+-+....

i ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI S....

+

+----+-----------.+-

+......-------

+...

+-----

22 72 NDD TSC TSC

.610 NPSNM 4

CI 22 72 NDD TEC TEH

.610 ZBAZC 67 HI 23 72 NDF P1 TSC

-. 05 TSC TSC

.610 NPSNM 4

CI 23 72 4.75 63 DTS P4 TSC

-. 05 TEC TEH

.610 ZBAZC 67 HI 24 72 NDD TSC TSC

.610 NPSNM 4

CI 24 72 2.51 66 MBM 6

04C 7.25 TEC TEH

.610 ZBAZC 67 HI 25 72 NDD TSC TSC

.610 NPSNM 4

Cl 25 72 NDD TEC TEH

.610 ZBAZC 67 HI 21 73 NDD TSC TSC

.610 NPSNM 6

CI 21 73 NDD TSH TSH

.610 NPSNM 19 HI 21 73 NDD TEC TEH

.610 ZBAZC 65 HI 22 73 NDD TSC TSC

.610 NPSNM 6

CI 22 73 NDD TSH TSH

.610 NPSNM 23 HI 22 73 NDD TEC TEH

.610 ZBAZC 65 HI 23 73 NDD TSC TSC

.610 NPSNM 6

CI 23 73 NDD TSH TSH

.610 NPSNM 23 H

23 73 NDD TEC TEH

.610 ZBAZC 65 HI 24 73 NDD TSC TSC

.610 NPSNM 6

CI 24 73 NOD TSH TSH

.610 NPSNM 23 HI 24 73 NDD TEC TEH

.610 ZBAZC 65 HI 25 73 NOD TSC TSC

.610 NPSNM 6

CI 25 73 NOD TSH TSH

.610 NPSNM 23 HI 25 73 NOD TEC TEH

.610 ZBAZC 65 HI 21 74 NOD TSC TSC

.610 NPSNM 4

CI 21 74 NDD TSH TSH

.610 NPSNM 21 HI 21 74 NOD TEC TEH

.610 ZBAZC 71 HI 22 74 NOD TSC TSC

.610 NPSNM 4

CI 22 74 NDD TSH TSH

.610 NPSNM 21 HI 22 74 NDD TEC TEH

.610 ZBAZC 71 HI 23 74 NOD TSC TSC

.610 NPSNM 4

CI 23 74 NOD TSH TSH

.610 NPSNM 21 HI 23 74 NOD TEC TEH

.610 ZBAZC 71 HI 24 74 NOD TSC TSC

.610 NPSNM 4

CI 24 74 NOD TSH TSH

.610 NPSNM 21 HI 24 74 NOD TEC TEH

.610 ZBAZC 71 HI 25 74 NDD TSC TSC

.610 NPSNM 4

C) 25 74 NDD TSH TSH

.610 NPSNM 21 HI 25 74 NOD TEC TEH

.610 ZBAZC 69 HI 37 78 NOD 02C 02C

.610 NPSNM 4

CI 37 78 2.10 179 ONG P1 03C 13.56 TEC TEH

.610 ZBAZC 69 HI 29 87 NDD 02C 02C

.610 NPSNM 4

CI 29 87 NOD TEC TEH

.610 SBACC 79 HI 30 88 NOD 02C 02C

.610 NPSNM 4

CI 30 88 NOD TEC TEH

.610 SBACC 77 HI 26 94 NDD 02C 02C

.610 NPSNM 4

CI 26 94 NOD TEC TEH

.610 SBACC 81 HI

+----+--------+

+----+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-

+----+----

-+-..

5 ST Max

SG - B COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:42:41

+

+

- - -+

+

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷.-----------+----+----+----+----+----+----+--+---

+-+--

+-

+-+...

+

I 28 98 NDD 02C 02C

.610 NPSNM 4

CI I

28 98 NDD TSH TSH

.610 NPSNM 29 HI I

28 98 NDD TEC TEH

.610 SBACC 81 HI I

I I

28 102 NDD 02C 02C

.610 NPSNM 4

Cl I

28 102 NDD TEC TEH

.610 SBACC 85 HI

+....

+---+---+-----

+----+-......+....-..+......--

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+..+...i---------------------------+-----..+..

+-

Tubes: 85 Records: 247 6

ST Max

SG - C EC BASED PLUS POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X

2 TUBE WITH EC BASED SI o 65 PLUGGED TUBE 10 105 100 95 90 85 80 75 70 O0000007OQ000000 00

-0.....

65 DOM000 60 55 50 45 40 35 30 25 20 15 10 TO 000000T0000 0.000P000.0O00 "o.........

... 00 Il 3..3

.,. 011... I,...°.

.. a0 5

45 40 35 25 20 15 0

00- 1....

la 00 O0.

0 0

00........................

+

O0

................................................................... 0..........................................

0.0 a

0.

0 0 S....

0 0.......

...-I....

I 0o 0 0

0.

oo.:.::::.o00...

oo_____

o

... '.o..

00 0

11::::

.. ao.....

0 0

0

°°.'

t t..

00...

° " t' "

oo...

.. o:

0 o0::

0 0)*::..

o 0..

o I...

000 :

. o

° 0

00 0.0' oo........

. r.............

0 o.........

..oo OC*...

0....

.i....

.... T.... T.... T..

..7 [

0o

.::I 0;.

1 1 T.

oo t... " °+ ' "

0.

. ~..1..

,, o. *.o o

.0::

: : : : : : : :: : : : : : : : : o oo o *o o *o o o o o
0.

0000 0000(

0000000000..

oo : "T T......

f:

.1 0"

.... f~t t~tt,

,fI

.....,..........t..

...........,I : :...t....

o.,,,,

o.,

O I.

..T.

.IT....

. T......

T

...T.... i..

.T 0°..

...I.

"T ° 00.

, o o.,,

o o,,o I....

' :'II1.

00 o..

l t///1/

ý 0 0.

0 0.

0o,,.'-

t,*.

  • .'o,,

..O O.

0.....

45 40 35 25 15 5

5 0

t 0,,° 0 I' II'

................................................*::~::::~.............1....1...:*f0**

  • 0....................................................

00...............................................

0..........00..........................000.

0000.....................0 00..........0 I

I 0.................................000.

T....

)0000$00000 0

0 0

0000 4000040000100000000000 00001p0000~100001o0000o0x00o000090000 0

oooocpoooo~oooo90000qoo00 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 Wesfinghouse Electric Company LLC - ST Max 10/2212009 20:26:05 25 20 15 10 5

SG -

C EC BASED PLUS POINT SPECIAL INTEREST PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 14:18:08 S-...--

+-

+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷....

+

÷

+----+----+

+---...--+

+-

÷ I

26 46 12.15 73 PLP 11 02C

.45 02C 02C

.610 NPSNM 12 CI I

26 46 2.98 75 MBM 6

04C 1.64 TEC TEH

.610 SBACC 67 HI I

I I

1 48

.25 165 DFS 1

02C

.63 11C TEC

.610 ZBAZC 4

CI I

1 48 NDF 2

02C

.63 02C 02C

.610 NPSNM 14 CI I

1 48 NOD 11H TEH

.610 SBACC 41 HI

+

+----+----..

+------

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+--------.----+----+----

+----+----+

Tubes: 2 Records:

5 1

ST Max

SG-C HOT LEG APPENDIX 12.8 + POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X 68 TUBE ON HL APPENDIX 12.8 a 65 PLUGGED TUBE 110 105 100 95 90 85 80 75 70 65 60 0...T...

.,..0 ToD 55 50 OOO000tO00C O0...

t*

45 40

,..OMO...O 35 30 DOOOOI 25 20 15 10 5

o 0o0 0

I i

0oo

'a.

00" T"

I1 1 ::001:0 13+: : I: :

.. o00 45 40 35 30 25 00 o..

i=

l = c =

oo[.......

]

.]

o 0

0

.0. 0 0

0 0

e ()I A

0 0o T.....

0 oo....

o

)o..

+......00

+.....o.........0 0............XXXX........o..............

0..

.......0*

0 0

00 0...

0: :1 00°

... 0..

o..

..0

(..

0...

..... o 0

X X X X. *,

  • 0 3

l* :...............

)O

.... 0o: X X -

+

oo

0.

0..............I

___ ::=

==

lxx i...

-I.o 00 i 0

0....

X XXX 0

0__.

.. 0 0.....

I 0 ~

~

~

~ ~

...°.

0 0O+

_0 00 OO.

I.........

O O.............................................

0:

0

° +

i~tiii..........

  • i....I

..........o o o o *

..... 0=

  • 0-oo o oo*.
: * + : : :.: +

0 o

.0 0

0...................

0 T

0 T........l.

0 0

.... ::: t "0: : :: :

T...

! t 0,"'0

.... !..:::10) 0:::

!10 0

-e *.e i.-.-

~.-.-

i.-.-.-.-

~

0

..i.

...i + = : ° t :

.f.

.i.

+

I...

..........o o......... I....o o...

x o

.o 13 0.

o+.

~ o++

+ -........

1 Z::: ::::

ooo... !... *.....

ooo.... x x...,... x x 0..

................... oo....oo

............ 13

....... *...oI~o.. + x o..t........ I 090.

000

.000()

0000 000 000.

45 35 25 20 15 15 5

5 oo:::i::::i::::

............................................................................................ v:::~.

0000 0000 OO' I.

"0

)oooo(PoO oo0o oo~oo oo(Poooo 0000 )O00PO0O

00) 00O00 0 000 0 0 0

0 000 O0 (O0(O00000000 0000 0000 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 WestinghouSe Electrc Company LLC - ST Max 10122/2009 20:26:08 35 30 25 20 15 10 5

SG -

C HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:43:36

+----.--------+----+..----.

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL Ll

+----+----+--------+--

+

-+--

8 2

NDD TSH TSH

.610 NPSNM 11 HI 8

2 2.85 174 DNG P1 10H 32.32 TEC TEH

.610 SBACC 45 HI 8

2 1.74 169 INR P1 liC

-. 70 TEC TEH

.610 SBACC 45 HI 8

2 2.17 178 DNG P1 loC 35.05 TEC TEH

.610 SBACC 45 HI 8

2 NDD 07H 08H

.610 NPSNM 115 HI 8

2 NDF 2

1OH 32.32 1OH 11H

.610 NPSNM 119 HI 9

2 NDD TSH TSH

.610 NPSNM 11 HI 9

2 NDD TEC TEH

.610 SBACC 45 HI 9

2 NOD 07H 08H

.610 NPSNM 115 HI 10 2

NDD TSH TSH

.610 NPSNM 11 HI 10 2

NDD TEC TEH

.610 ZBAZC 49 HI 10 2

NDD 07H 08H

.610 NPSNM 115 HI I11 2

NDD TSH TSH

.610 NPSNM 13 HI I11 2

NDD TEC TEH

.610 ZBAZC 49 HI I11 2

NDD 07H 08H

.610 NPSNM 115 HI 12 2

NDD TSH TSH

.610 NPSNM 13 HI 12 2

1.61 157 DFS 1 loC 24.83 TEC TEH

.610 ZBAZC 49 HI 12 2

4.49 174 DNG Pi loC 25.74 TEC TEH

.610 ZBAZC 49 HI 12 2

NDD 07H 08H

.610 NPSNM 115 HI 8

3 NOD TSH TSH

.610 NPSNM 11 HI 8

3 NOD TEC TEH

.610 SBACC 47 HI 8

3 NDD 07H 08H

.610 NPSNM 115 HI 9

3 NOD TSH TSH

.610 NPSNM 11 HI 9

3 3.20 182 ONG P1 loC 33.32 TEC TEH

.610 SBACC 45 HI 9

3 NOD 07H 08H

.610 NPSNM 117 HI 10 3

NDD TSH TSH

.610 NPSNM 11 HI 10 3

.41 164 DFI 1

08H

-. 90 TEC TEH

.610 SBACC 47 HI 10 3

TBP 2

07H 08H

.610 NPSNM 117 HI 10 3

.17 108 PCT 20 2

08H

-. 98 07H 08H

.610 NPSNM 117 HI 10 3

.14 88 SVI P4 08H

-. 82 07H 08H

.610 NPSNM 117 HI 11 3

NDD TSH TSH

.610 NPSNM 11 HI 11 3

NDD TEC TEH

.610 SBACC 47 HI 11 3

NDD 07H 08H

.610 NPSNM 115 HI 12 3

NDD TSH TSH

.610 NPSNM 11 HI 12 3

NDD TEC TEH

.610 ZBAZC 49 HI 12 3

NDD 07H 08H

.610 NPSNM 115 HI 8

4 NOD TSH TSH

.610 NPSNM 13 HI 8

4 NDD TEC TEH

.610 SBACC 47 HI 8

4 NDD 07H 08H

.610 NPSNM 115 HI 9

4 NOD TSH TSH

.610 NPSNM 13 HI 9

4 2.30 178 0NG P1 11H 13.95 TEC TEH

.610 SBACC 45 HI 9

4 NOD 07H 08H

.610 NPSNM 115 HI I10 4

NDD TSH TSH

.610 NPSNM 13 HI 10 4

1.63 87 INR 6

1OH 17.13 TEC TEH

.610 SBACC 47 HI 10 4

NOD 07H 08H

.610 NPSNM 115 HI 11 4

NOD TSH TSH

.610 NPSNM 13 HI 11 4

9.63 179 DNG P1 loC 30.95 TEC TEH

.610 SBACC 47 Hi 11 4

NDD 07H 08H

.610 NPSNM 115 HI 12 4

NOD TEC TEH

.610 SBACC 47 HI 12 4

NOD 07H 08H

.610 NPSNM 115 HI

+----------------..

+

+----+----+-

.+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI 4-.-----------.----+----------------+

+--

+

+-.

1 ST Max

SG - C HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 ODE 20091001 10/22/2009 13:43:36

-+----+--------

+--*--

-+..----

+--

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+..

+.----------. ----.----.----.----.----------

+-

-+-...

+

÷

+

+--÷.

÷ 8

8 9

9 10 10 11 11 12 12 12 6

6 7

7 7

8 8

9 9

10 10 6

6 7

7 8

8 99 10 10 6

6 7

7 9

9 10 10 6

6 6

7 7

5

.30 111 DFS 1 10C 34.16 5

5 5

5 5

5 5

5 5

5 16 16 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 17 17 17 17 18 18 18 18 18 18 18 18 19 19 19 19 19 NDD NDD NDD 1.82 170 INR NDD 3.75 181 DNG NDD NDF NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDD NDF NDF P1 10H 38.32 P1 03H 2

03H 9.18 9.18 TEC TEH

.610 SBACC 47 HI 07H 08H

.610 NPSNM 117.

HII TEC TEH

.610 ZBAZC 49 HI 07H 08H

.610 NPSNM 117 HI TEC TEH

.610 ZBAZC 49 HI 07H 08H

.610 NPSNM 117 HI TEC TEH

.610 ZBAZC 49 HI 07H 08H

.610 NPSNM 117 HI 03H 05H

.610 NPSNM 119 HI TEC TEH

.610 ZBAZC 49 HI 07H 08H

.610 NPSNM.

117 HI TEC TEH

.610 SBACC 55 HI 07H 07H

.610 NPSNM 115 HI TEC TEH

.610 SBACO 51 HI TEC TEH

.610 SBACC 55 HI 07H 07H

.610 NPSNM 115 HI TEC TEH

.610 SBACC 51 HI 07H 07H

.610 NPSNM 115 HI TEC TEH

.610 SBACC 51 HI 07H 07H

.610 NPSNM 115 HI TEC TEH

.610 SBACC 51 HI 07H 07H

.610 NPSNM 115 HI TEC TEH

.610 ZBAZC 57 HI 07H 07H

.610 NPSNM 117 HI TEC TEH

.610 ZBAZC 57 HI 07H 07H

.610 NPSNM 117 HI TEC TEH

.610 ZBAZC 57 HI 07H 07H

.610 NPSNM 117 HI TEC TEH

.610 ZBAZC 57 HI 07H 07H

.610 NPSNM 117 HI TEC TEH

.610 ZBAZC 57 HI 07H 07H

.610 NPSNM 117 HI TEC TEH

.610 SBACO 55 HI 07H 07H

.610 NPSNM 115 HI TEC TEH

.610 SBACC 55 HI 07H 07H

.610 NPSNM 115 HI TEC TEH

.610 SBACC 55 Hi 07H 07H

.610 NPSNM 115 HI TEC TEH

.610 SBACC 55 HI 07H 07H

.610 NPSNM 115 HI TSH TSH

.610 NPSNM 15 HI TEC TEH

.610 ZBAZC 57 HI 07H 07H

.610 NPSNM 117 HI TSH TSH

.610 NPSNM 15 HI TSH TSH

.610 NPSNM 15 HI 2

TSH

-13.58 2

TSH

-13.31 I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI S....

+--I----+---+---+---

-+-

-I---+-

÷--

+......

I---

2 ST Max

SG -

C HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:43:36

+

+----+----+.........--------

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Ll

..--------. +----+----+----+

+- +-.-

7 19 NDF 2

TSH

-12.63 TSH TSH

.610 NPSNM 15 HI 7

19

.27 156 DFS 1

10H 37.23 TEC TEH

.610 ZBAZC 57 HI 7

19 1.89 173 INR P1 10H 41.92 TEC TEH

.610 ZBAZC 57 HI 7

19 6.02 173 DNG P1 10C 32.79 TEC TEH

.610 ZBAZO 57 HI 7

19 11.07 179 DNG P1 10C 33.83 TEC TEH

.610 ZBAZC 57 HI 7

19 NDD 07H 07H

.610 NPSNM 117 HI 8

19 NDF 2

TSH

-13.71 TSH TSH

.610 NPSNM 15 HI 8

19 NDD TEC TEH

.610 ZBAZC 57 HI 8

19 NDD 07H 07H

.610 NPSNM 117 HI 9

19 NDD TSH TSH

.610 NPSNM 15 HI 9

19 NDD TEC TEH

.610 ZBAZC 57 HI 9

19 NDD 07H 07H

.610 NPSNM 117 HI 10 19 NDD TSH TSH

.610 NPSNM 15 HI 10 19 NDD TEC TEH

.610 ZBAZO 57 HI 10 19 NDD 07H 07H

.610 NPSNM 117 HI 6

20 NDD TSH TSH

.610 NPSNM 17 HI 6

20 1.96 70 INR 6

01H 4.94 TEC TEH

.610 SBACC 55 HI 6

20 2.06 76 MBM 6

07H 10.64 TEC TEH

.610 SBACC 55 HI 6

20 1.95 74 INR 6

08H 19.94 TEC TEH

.610 SBACC 55 HI 6

20 NDD 07H 07H

.610 NPSNM 115 HI 7

20 NDD TSH TSH

.610 NPSNM 17 HI 7

20 NOD TEC TEH

.610 SBACC 55 HI 7

20 NOD 07H 07H

.610 NPSNM 115 HI 8

20 NDD TSH TSH

.610 NPSNM 17 HI 8

20

.37 155 DFS 1

09H 4.09 TEC TEH

.610 SBACC 55 HI 8

20 NOD 07H 07H

.610 NPSNM 115 HI 9

20 NDF 2

TSH

-14.65 TSH TSH

.610 NPSNM 17 HI 9

20 NDF 2

TSH

-14.37 TSH TSH

.610 NPSNM 17 HI 9

20 NDF 2

TSH

-13.55 TSH TSH

.610 NPSNM 17 HI 9

20 NDD TEC TEH

.610 SBACC 55 HI 9

20 NDD 07H 07H

.610 NPSNM 115 HI 10 20 NOD TSH TSH

.610 NPSNM 17 HI 10 20 NOD TEC TEH

.610 SBACC 55 HI 10 20 NDD 07H 07H

.610 NPSNM 115 HI 33 42 NOD TEC TEH

.610 SBACC 67 HI 33 42 NOD 08H 08H

.610 NPSNM 115 HI 34 42 NOD TEC TEH

.610 SBACC 67 HI 34 42 NDD 08H 08H

.610 NPSNM 115 HI 35 42 2.02 70 MBM 6

05H 19.59 TEC TEH

.610 SBACC 67 HI 35 42 NOD 08H 08H

.610 NPSNM 115 HI 36 42 NOD TEC TEH

.610 SBACC 67 HI 36 42 NOD 08H 08H

.610 NPSNM 115 HI 37 42 NDD TEC TEH

.610 SBACC 67 HI 37 42 NOD 08H 08H

.610 NPSNM 115 HI 33 43 NOD TSH TSH

.610 NPSNM 17 HI 33 43 NOD TEC TEH

.610 SBACC 69 HI 33 43 NDD 08H 08H

.610 NPSNM 117 HI 34 43 NOD TSH TSH

.610 NPSNM 17 HI 34 43 NOD TEC TEH

.610 SBACC 69 HI 34 43 NOD 08H 08H

.610 NPSNM 117 HI

+-

+-------...

÷....+-

÷ I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-----------

+-

3 ST Max

SG -

C HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:43:36

+----...+...------+----

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-----------+----.----.----.--------.

+

.+-

+--

35 43 NDF 2

TSH

-11.74 TSH TSH

.610 NPSNM 17 HI 35 43 NDD TEC TEH

.610 SBACC 69 HI 35 43 NDD 08H 08H

.610 NPSNM 117 HI 36 43 NDD TSH TSH

.610 NPSNM 5

Hi 36 43 NDD TEC TEH

.610 SBACC 69 HI 36 43 NDD 08H 08H

.610 NPSNM 117 HI 37 43 NOD TSH TSH

.610 NPSNM 5

HI 37 43 NOD TEC TEH

.610 SBACC 69 HI 37 43 NDD 08H 08H

.610 NPSNM 117 HI 33 44 NDD TSH TSH

.610 NPSNM 15 HI 33 44 NDD TEC TEH

.610 SBACC 67 HI 33 44 NOD 08H 08H

.610 NPSNM 115 HI 34 44 NDD TSH TSH

.610 NPSNM 15 HI 34 44 NDD TEC TEH

.610 SBACC 67 HI 34 44 NDD 08H 08H

.610 NPSNM 115 HI 36 44 NDD TSH TSH

.610 NPSNM 15 HI 36 44 NOD TEC TEH

.610 SBACC 67 HI 36 44 NOD 08H 08H

.610 NPSNM 115 HI 37 44 NOD TSH TSH

.610 NPSNM 15 HI 37 44 NDD TEC TEH

.610 SBACC 67 HI 37 44 NDD 08H 08H

.610 NPSNM 115 HI 33 45 NOD TEC TEH

.610 SBACC 69 HI 33 45 NOD 08H 08H

.610 NPSNM 117 HI 34 45 NOD TEC TEH

.610 SBACC 69 HI 34 45 NDD 08H 08H

.610 NPSNM 117 HI 37 45 2.11 77 MBM 6

08C 35.29 TEC TEH

.610 SBACC 69 HI 37 45 NOD 08H 08H

.610 NPSNM 117 HI 33 46 NOD TEC TEH

.610 SBACC 67 HI 33 46 NDD 08H 08H

.610 NPSNM 115 HI 34 46 2.03 81 MBM 6

04C 15.29 TEC TEH

.610 SBACC 67 HI 34 46 NOD 08H 08H

.610 NPSNM 115 HI 37 46 NDD TEC TEH

.610 SBACC 67 HI 37 46 NDD 08H 08H

.610 NPSNM 115 HI 34 47 NOD TEC TEH

.610 SBACC 69 HI 34 47 NOD 08H 08H

.610 NPSNM 117 HI 35 47 NOD TEC TEH

.610 SBACC 69 HI 35 47 NOD 08H 08H

.610 NPSNM 117 HI 36 47 NDD TEC TEH

.610 SBACC 69 HI 36 47 NDD 08H 08H

.610 NPSNM 117 HI 37 47 NOD TEC TEH

.610 SBACC 69 HI 37 47 NDD 08H 08H

.610 NPSNM 117 HI

+----+----+-----------+-----+-----+-----+

+


+-----+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Ll

+-------+-----+-----+-----+-----+-----+

+


+-----+

+--------

Tubes: 68 Records: 186 4

ST Max

SG-C COLD LEG APPENDIX 12.8 + POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X 20 TUBE ON CL APPENDIX 12.8 a 65 PLUGGED TUBE 110 105 100 95 85 80 75 70 65 60 O0000000000000C)O0000fOal000O 0

m00

  • 0 --.

,a 01 0

93 0

55 50 45 40

'O0O0010 OI0000 35 30 00000 I 25 20 15 10 5

, o0 0

000 I.

m00 00.--*

45 35 30 25

00.

00 00 I10 O.........00 Q

.0

)0.

.I

0.

O............

_E(

G_

C C

I

~

o 0

O0.

0 0

0 0.*

a.

{

0 0 o.... o,.

7.......

[]0

. o....

0 0...

1*.

1-..

.oo.

0.

1 1o::

.. 000:o

.......0.o o....... o o

0.

. -.o o.-o1 o.-,..oa o0

........ : :i

°

'.?* ::

) 0.....

0 0....

10 0-0

0)
0...

O Io0....

0............

0 00..............0 0]

S.......................

0.

e_

0_-

O_

0

.0......

T 0 0..

o-.-.--

6-0 a

t.---

10 0

o oo..........

i Co... o..

00 0

0..o 00

.0 0..

000 00 0 o~~~~~~..

[

(( [ [

[ [ [ [

°°~~ ~~~~~~~ ~~~~~~~~

00..

..I..

..I ']

..I..

1 i : i 1 1 i 0

0

-I 0..

°***To°*

  • .0.

00o0o.°° o

o

°,

o o,.............................

0.

0 o o... 0 !......

i*°°

0.
t.

......... 0

~~~~~~~~~~~~~~

oo oo...

  • oo 45 40 35 25 15 15 10 5

5 0..

C...

0000 t....T....

0 0 00 0 0 0 0 00O000 0I00 110 105 100 95

XXýýIx X 50 45.40.

]..

50 45 40

....I..... i i i.

oooo1oooo0oooo(toooo0oooo 25 20 15 10 5

Po0000p000*P000090000PO0000cp0 0()00000(pO000 90 85 80 75 70 65 60 55 T000090000 35 30 Westinghouse Electric Company LLC - ST Max 10=22/2009 2025:56

SG -

C COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:44:16 S....

+----+-----------+-----

-+..----+-

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+...

- --------------.---- +----+----+-------

-+------+---+..-----.

+-+-+-

22 20 NDD TSH TSH

.610 NPSNM 7

HI 22 20 NDD 02C 02C

.610 NPSNM 12 C0 22 20 NDD TEC TEH

.610 SBACC 55 HI 44 44 NDD 02C 02C

.610 NPSNM 12 C0 44 44 NDD TSH TSH

.610 NPSNM 15 HI 44 44 NDD TEC TEH

.610 SBACC 67 HI 25 45 NDD 02C 02C

.610 NPSNM 12 C0 25 45 NDD TEC TEH

.610 SBACC 69 HI 22 70 NDD 02C 02C

.610 NPSNM 12 CI 22 70 NDD TEC TEH

.610 SBACC 99 HI 31 70 NDD 02C 02C

.610 NPSNM 12 C0 31 70 NDD TEC TEH

.610 SBACC 81 HI 32 70 NDD 02C 02C

.610 NPSNM 12 CI 32 70 NDD TEC TEH

.610 SBACC 81 HI 3

83 NDD 11C TEC

.610 ZBAZC 6

CI 3

83 NDD 05C 05C

.610 NPSNM 12 Cl 3

83 NDD 11C TEH

.590 SBUCC 109 HI 4

83 NDD 11C TEC

.610 ZBAZC 6

CI 4

83 NDD 05C 05C

.610 NPSNM 12 C0 4

83 NDD 11C TEH

.590 SBUCC 109 HI 5

83 NDD 05C 05C

.610 NPSNM 12 CI 5

83 NDD TEC TEH

.610 SBACC 99 HI 3

84 NDD 11C TEC

.610 ZBAZC 8

CI 3

84 NDD 05C 05C

.610 NPSNM 12 CI 3

84 NDD 11C TEH

.590 SBUCC 109 HI 4

84 NDD 11C TEC

.610 ZBAZC 6

CI 4

84 NDD 05C 05C

.610 NPSNM 12 CI 4

84 NDD 11C TEH

.590 SBUCC 109 HI 5

84 NDD 05C 05C

.610 NPSNM 12 CI 5

84 NDD TEC TEH

.610 SBACC 99 HI 4

85 2.42 182 DNG P1 04C 16.78 11C TEC

.610 ZBAZC 6

CI 4

85 5.94 182 DNG PI 01C 2.02 11C TEC

.610 ZBAZC 6

CI 4

85 NDD 05C 05C

.610 NPSNM 12 CI 4

85 NDD TSH TSH

.610 NPSNM 29 HI 4

85 NDD 11C TEH

.590 SBUCC 109 HI 5

85 NDD 05C 05C

.610 NPSNM 12 CI 5

85 NDD TSH TSH

.610 NPSNM 29 HI 5

85

.26 99 DFS 1 01H 20.49 TEC TEH

.610 SBACC 99 HI 3

86 NDD 11C TEC

.610 ZBAZC 8

CI 3

86 NDD 05C 05C

.610 NPSNM 12 CI 3

86 NDD TSH TSH

.610 NPSNM 31 HI 3

86 NDD 11C TEH

.590 SBUCC 109 HI 4

86 NDD 11C TEC

.610 ZBAZC 6

CI 4

86 NDD 05C 05C

.610 NPSNM 12 CI 4

86 NDD TSH TSH

.610 NPSNM 31 HI 4

86 NDD 11C TEH

.590 SBUCC 109 HI 5

86 NDD 05C 05C

.610 NPSNM 12 CI 5

86 NDD TSH TSH

.610 NPSNM 31 HI 5

86 NDD TEC TEH

.610 SBACC 99 HI

+--------+....----+----....-----

-+......

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷--------+----+----

+-

1 ST Max

SG -

C COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:44:16

+

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----+----.----.----.----..

+

+..----+-

3 87 NDD 11C TEC

.610 ZBAZC 8

CI 3

87 NDD 05C 05C

.610 NPSNM 12 CI 3

87 NDD 11C TEH

.590 SBUCC 109 HI 4

87 2.27 182 DNG P1 09C 28.91 11C TEC

.610 ZBAZC 6

CI 4

87 NDD 05C 05C

.610 NPSNM 12 CI 4

87 NDD 11C TEH

.590 SBUCC 109 HI 5

87 NDD 05C 05C

.610 NPSNM 12 Cl 5

87 NDD TEC TEH

.610 SBACC 99 HI

+----+----.--------..--------

+-

+-

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Ll

+--------------+..-------------+-----

+


+-----

-÷--4 Tubes: 20 Records: 57 ST Max 2

SG - D EC BASED PLUS POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X

3 TUBE WITH EC BASED SI a 26 PLUGGED TUBE 110 105 100 95 90 85 80 75 70 65 60 I0000O000q 0*oXO()00p00000()O 55 0qO000O 0 -

i....

1 0

50 45 40 35 30 0

07 0 0

0 0 0 0

0 0 0 0 0 01

0

' 0°°°

......... I...... *..0 25 20 15 10 5

oo.X

.?.

I O t1

°"::

45 40 35 45 25 00.............

0.......

0.....

oo*....

A....................o.o......T....

T T........0000

00.

._0 a 0

00.

0

.0 o 0

' - ' ' : -~....

OTC..

....o

00....

........... 0 0

00 0...

.. 0 000.

0 0..............

0000.T....

0........

0.......o..0 o o0...

..00....

0.....

0

0.......... 0"

..............O..

o......

0 T

-oI I

0 0000.0000.00....

0 0'

0 O0 0

0..

....... 0 00

  • .:,,..,........... o...

to.

......0

. oo I.

: : : :1
  • I
  • oo+....

I....

I....

T........

T

......... i 0

-O1 0...

0-0..

o

-o o o o T....

o.....

0: 1.

,o oo

0.

00 0 00 0) 0 01 0 0......0 0..

1.00.....

.... 0 ).

.l

/

ei.

0

....................................................., t......................... *.............0t!1

0.

T 0000....................

0 00 0 00 0 00 0 00000

..... i..........

...... 00 0

'T

1.

0 oo 0

o o o 0...

0....

T:

0 0 : :

0 0

Oo

,o

.,,,~

~~

oo o

eO o

O o..

T..

.o o..

]

...ooo

.l

.ooi.

T

,...o o

oo...

1 1'"

..T..

.T.

..T '

oo :.. o [..,i...

........ i__ o 35 30 25 20 15 10 15 5

5 0,*

0***

0...

0000 110 10 5 P0 95 0

85 0

00 0

70000000 110 105 100 95 90 8

0 7

T" 0..

00000000 0000 P0000

$00000000 65 60 55 50 45 40 35 30 25 20 15 10 5

,0000 70 Westinghouse Electic Company LLC - ST Max 10122t2009 20:28:41

SG -

D EC BASED PLUS POINT SPECIAL INTEREST PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 14:18:08 S---

+

+-

+---------

+- --

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI S....

+-------+-----

+

+..----

+-.

+

12 10 NDD TSH TSH

.610 NPSNM 3

HI 12 10 4.80 175 DNG P1 10H 40.62 TEC TEH

.610 SBACC 43 HI 12 10 NOF 2

10H 40.62 1OH 11H

.610 NPSNM 105 HI 49 72 3.82 64 DTS P4 TSH

-. 19 TEC TEH

.610 SBACC 55 HI 49 72 NDF 2

TSH

-. 19 TSH TSH

.610 NPSNM 105 HI 46 86 NDF 2

11C

-. 55 1iC 1iC

.610 NPSNM 10 CI 46 86 NDD TSH TSH

..610 NPSNM 19 HI 46 86

.38 127 DSS P1 liC

-. 55 TEC TEH

.610 SBACC 69 HI 46 86 PBC P1 TEC TEH

.610 ZBAZC 115 HI

+----+--------

-+----+----

+-------

+---

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----.----.--------

+---------------

+--

Tubes: 3 Records: 9 1

ST Max

SG-D HOT LEG APPENDIX 12.8 + POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 X 15 TUBE ON HL APPENDIX 12.8 0 26 PLUGGED TUBE

.10 105 100 95 90 85 80 75 70 65 60 55 50 45 o0..

o,0*

o oT oo00 o0oo0o oooo0 o.o.

o0 o.

0 o0 I

00..

..I..

... ] o..

..T..

oo....

o

.T.

40 o0000 35 30 25 20 15 10 0000

)00 000 5

T..

45 35 30 25 0

I.

0 0

0 I"..

I

- -O0..

_e3_

... 0 voo

00. o*0..............................T....

I.....'........

[

T.....

T.......

Io 0......0....,.........

i...........

[

  • ....000......

X"'0.*.............00~

S 0

1.3 0.......

00.

..00 oo

~**-*-

1

.T T 7 S.........

oo.x.

00 0...

0 0

.o o0 0

0 0

0.

0 00 0..

.0 0

0.......

7222!...

1... 0, o0...................

{..........

1 1 ]

.... T.....T.......................

0" 0

.. i.... I.... T.....

o T...................

+.....I........

I " l T

0.... T........ !....

.. °

.......° ° 00

.T..

0

()

l 00 T...

0..

v.of............

0.

]....

I.....T.....

o o o o o

.T.

0

. T..

  • T ' H H
  • T...

..T...

T....T.......

0-00..........

.... 0 o,T.

I

- - -I....

' ***I o.

0

.... T..

0:

t 0

.0.0....I

o.

T 0

T 0.......

..o 0.....

00 0 0o0 0 00 T....

... 0 0..

o:

00...0T o o....

t...

°°)

.. T....

oo0

...... T o (

T0..1...

.I.

45 40 35 30 25 15 15 10 5

5 i... T...

... i.... f.....

-000 00*.0 0...

0.

.0$ 00.

0

-0000

-00ý0.0o~oý000ý000ý000ý.-Odý00ood0ooo 000~p000.q0000q0000qop000.cP.000q0000c0000900.0o-110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 Westinghouse Electric Company LLC - ST Max 10/2212009 20 28:42 35 30 25 20 15 10 5

SG - D HOT LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:44:59

+....

+--....+-+--.-+...--.-

+-+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷

+----+--..

+.----+----.----.-÷

.÷---

+--4

-+

34 59 NDD TSH TSH

.610 NPSNM 17 Hi 34 59 NDD TSH TSH

.610 NPSNM 21 HI 34 59 NDD TEC TEH

.610 ZBAZC 57 HI 35 59 NDD TSH TSH

.610 NPSNM 17 HI 35 59 NDD TSH TSH

.610 NPSNM 21 HI 35 59 NDD TEC TEH

.610 ZBAZC 57 HI I36 59 NDF 2

TSH

-1.34 TSH TSH

.610 NPSNM 17 H

36 59 NDF 2

TSH

.30 TSH TSH

.610 NPSNM 17 HI 36 59 NDF 2

TSH

-1.34 TSH TSH

.610 NPSNM 21 HI 36 59 NDF 2

TSH

.00 TSH TSH

.610 NPSNM 21 HI 36 59 NDD TEC TEH

.610 ZBAZC 57 HI 37 59 NOD TSH TSH

.610 NPSNM 17 HI 37 59 NDD TSH TSH

.610 NPSNM 21 HI 37 59 NDD TEC TEH

.610 SBACC 51 HI 38 59 NOD TSH TSH

.610 NPSNM 17 HI 38 59 NDD TSH TSH

.610 NPSNM 21 HI 38 59 NOD TEC TEH

.610 SBACC 51 HI 34 60 NDD TSH TSH

.610 NPSNM 17 HI 34 60 NDD TSH TSH

.610 NPSNM 21 HI 34 60 NDD TEC TEH

.610 SBACC 55 HI 35 60 NDD TSH TSH

.610 NPSNM 17 HI 35 60 NDD TSH TSH

.610 NPSNM 21 HI 35 60 NDD TEC TEH

.610 SBACC 55 HI 37 60 NOD TSH TSH

.610 NPSNM 17 HI 37 60 NDD TSH TSH

.610 NPSNM 21 HI 37 60 NDD TEC TEH

.610 ZBAZC 53 HI 38 60 NDD TSH TSH

.610 NPSNM 17 HI 38 60 NDD TSH TSH

.610 NPSNM 21 HI 38 60 NDD TEC TEH

.610 ZBAZC 53 HI I36 61

.10 71 VOL P4 TSH

.0 TSH TSH

.610 NPSNM 9

HI 36 61

.09 66 VOL P4 TSH

.00 TSH TSH

.610 NPSNM 17 HI 36 61

.12 308 VOL P4 TSH

.02 TSH TSH

.610 NPSNM 21 HI 36 61

.14 294 PCT 16 2

TSH

.02 TSH TSH

.610 NPSNM 21 Hi 36 61 NDD TEC TEH

.610 SBACC 51 HI 34 63 NOD TSH TSH

.610 NPSNM 17 HI 34 63 NDD TSH TSH

.610 NPSNM 21 HI 34 63 NDD TEC TEH

.610 ZBAZC 57 HI 35 63 NOD TSH TSH

.610 NPSNM 17 HI 35 63 NDD TSH TSH

.610 NPSNM 21 HI 35 63 NDD TEC TEH

.610 SBACC 51 HI 36 63 NOD TSH TSH

.610 NPSNM 17 HI 36 63 NDD TSH TSH

.610 NPSNM 21 HI 36 63 NDD TEC TEH

.610 SBACC 51 HI 37 63 NOD TSH TSH

.610 NPSNM 17 HI 37 63 NDD TSH TSH

.610 NPSNM 21 HI 37 63 NDD TEC TEH

.610 SBACC 51 HI 38 63 NDD TSH TSH

.610 NPSNM 17 HI 38 63 NDD TSH TSH

.610 NPSNM 21 HI 38 63 NDD TEC TEH

.610 SBACC 51 HI

+....

+

+.......

+..

+....

+

+.--÷-

4

+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+...

+

+.....

+--....

+-...-.+..----..+

+-

-+-+-

-4

+

Tubes: 15 Records: 49 1

ST Max

SG - D COLD LEG APPENDIX 12.8 + POINT SPECIAL INTEREST PROGRAM Braidwood A2R14 CDE D5 F 20 TEST 02C +/-

3" CORNER TUBE A 16 ADDITIONAL TUBES TEST 02C

+/-3" X

2 TEST 02C +/- 3" a 26 PLUGGED TUBE 5

10 15 20 25 F

FFA AA,.

30 IF F, F 35 40 45 50 55 60 65 70 75 80 85 90 95 100

  • ~~~~~~~

~~

~

~

~ ~

F..i::::i..

.I I F F I....

I.... I....

T'

.a...

.... I A A 05 10@

45 40 35 25 I

F.

FF.......

T...

FF aa.............a..............

.an

  • .0F O~

.O..

?)

I°.

000....................

° 00..

I, 0...........

0 T

1....

00..

0..00....0T oo....

oo..o......

0....

.....0 0......................................V* *t*

  • 0..........................................

00.....

o.......T....

.o.

oI,.......

0 00.

0 0

o t

00 0

00 00 0

000 0

0 o0....

.0o 0

00 0000 0000 o o

..............I........

0................

0 o

o:..

. T T

I ::

  • I**

o

.o.........

......0 0 0

...0 0....

0 I....

t o.

0...

..... T....

0

............... T.........

.T.

T..

I:

TO:

o l..

.T....

T.

0o

.. T.

..I.

..T.

... T......... i......... T.... T..... 0 o...... I..I.. : :....*

...0 o

T..

I ZZ

.00...

oo.

0 0.

0000

. 1.

T...

0...

..oo 0

0........

0 0....

i 0.*

0000 00 o0.

Io.

o....

T0 1

o...

oooo.........0 oo I....

00...........................

I"

. : i : :I

........I........

.o oo....

I: ::...T....

.. T.. I..

..... I....

..... I....

I......

00 45 40 35 25 15 10 5

15 5

0........

0.........

000040000

1: -. --11
-::e ooo0ooooý000o0ooo0oooo0ooboo(oooooooooooooooo0 00.0 0 00 0 0 0 0 a 000.0 0

)0000 5

10 15 20 25 30 35 40 45 50 55 60 65 70 Westinghouse Electnc Company LLC ' ST Max 1012312009 14:35:07 75 80 85 90 95 100 105 110

SG - D COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/23/2009 14:04:03

+-

-+-

÷

+-

÷

÷ I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----.----.----.

+

+----

+-+-....--

30 17 NDD 02C 02C

.610 NPSNM 16 C0 30 17 NDD TEC TEH

.610 ZBAZC 45 HI 42 21 NDD 02C 02C

.610 NPSNM 12 C0 42 21 2.64 178 DNT P1 AV2

-. 06 TEC TEH

.610 ZBAZC 49 HI 42 21 3.46 179 DNT P1 AV3

.18 TEC TEH

.610 ZBAZC 49 HI 42 22 NDD 02C 02C

.610 NPSNM 12 C0 42 22

.30 43 DSS P1 07C

-. 22 TEC TEH

.610 SBACC 47 HI 43 22 NDD 02C 02C

.610 NPSNM 12 CI 43 22 3.24 181 DNT P1 AV2

.05 TEC TEH

.610 SBACC 47 HI 43 23 NDD 02C 02C

.610 NPSNM 12 C0 43 23 NDD TEC TEH

.610 ZBAZC 49 HI 44 23 NDD 02C 02C

.610 NPSNM 12 CI 44 23 NDD TEC TEH

.610 ZBAZC 49 HI 44 24 NDD 02C 02C

.610 NPSNM 12 CI 44 24 NDD TEC TEH

.610 SBACC 47 HI 45 24 NDD 02C 02C

.610 NPSNM 12 CI 45 24 NDD TEC TEH

.610 ZBAZC 49 HI 45 25 NDD TSH TSH

.610 NPSNM 5

HI 45 25 NDD 02C 02C

.610 NPSNM 12 C0 45 25 NDD TEC TEH

.610 ZBAZC 49 HI 45 26 NDD TSH TSH

.610 NPSNM 7

HI 45 26 NDD 02C 02C

.610 NPSNM 12 CI 45 26 NDD TEC TEH

.610 SBACC 47 HI 46 26 NDD TSH TSH

.610 NPSNM 7

HI 46 26 NDD 02C 02C

.610 NPSNM 12 CI 46 26

.38 44 DFS 1

07H 2.71 TEC TEH

.610 SBACC 47 HI 46 27 NDD 02C 02C

.610 NPSNM 12 C0 46 27 NDD TEC TEH

.610 ZBAZC 49 HI 47 27 NDD 02C 02C

.610 NPSNM 12 CI 47 27 6.23 185 DNG P1 1OH 16.80 TEC TEH

.610 ZBAZC 49 HI 47 27 2.15 185 DNG P1 1OH 17.51 TEC TEH

.610 ZBAZC 49 Hi 47 28 NDD 02C 02C

.610 NPSNM 12 C0 47 28 3.37 183 DNT P1 AV4

-. 24 TEC TEH

.610 SBACC 47 HI 47 29 NDD 02C 02C

.610 NPSNM 12 C0 47 29 NDD TEC TEH

.610 ZBAZC 49 HI 48 29 NDD 02C 02C

.610 NPSNM 12 CI 48 29 5.24 179 DNT P1 AVi

.00 TEC TEH

.610 ZBAZC 49 HI 48 29 2.83 169 DNG P1 07C 13.47 TEC TEH

.610 ZBAZC 49 HI 48 30 NDD 02C 02C

.610 NPSNM 12 CI 48 30 NDD TEC TEH

.610 SBACC 47 HI 48 31 NDD TSH TSH

.610 NPSNM 5

HI 48 31 NDD 02C 02C

.610 NPSNM 12 C0 48 31 NDD TEC TEH

.610 ZBAZC 49 HI 49 31 NDD TSH TSH

.610 NPSNM 7

HI 49 31 NDD 02C 02C

.610 NPSNM 12 CI 49 31

.31 70 DFS 3

11H 3.68 TEC TEH

.610 ZBAZC 49 HI 49 31 4.10 177 DNT PI AV4

.00 TEC TEH

.610 ZBAZC 49 HI S....

l------------+----+----+----+----+-------

-+

-I---------+

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----+----+----+----+

+------+----+.----+-

+

+-

I ST Max

SG -

D COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/23/2009 14:04:03

+----+----+--------


+-------+.-----

+-+-...--

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Ll

+

+

+-----.

+-

+---...--

34 34 48 48 49 49 48 48 48 47 47 47.

48 48 48 47 47 47 46 46 46 46 47 47 47 47 47 47 47 47 45 45 46 46 45 45 44 44 44 45 45 45 45 43 43 43 44 44 44 69 69 84 84 84 84 85 85 85 86 86 86 86 86 86 87 87 87 88 88 88 88 88 88 88 88 88 88 88 88 89 89 89 89 90 90 91 91 91 91 91 91 91 92 92 92 92 92 92 14.16 79 PLP NDD NDD NDD NDD NOD NDD NDD NOD NOD NOD 4.05 178 ONG NOD NOD NOD NOD NDD NDD NOD NOD 2.64 165 DNT 7.39 179 DNT NOD NOD 3.68 176 DNT 4.69 180 DNT 7.89 182 ONG 4.02 180 DNT NDF NDF NOD NDD NOD 2.59 175 DNT NDD NDD NOD NOD NOD NDD NDD

.94 163 DFS 1.20 169 DFS NDD NDD NOD NOD NOD 11 02C

.41 P1 09H 26.24 P1 liC P1 liC P1 P1 P1 PI 2

2 11H 11H 11H AV3 11H 11H

-. 58

.50

-. 66

.33 6.94

.19

-. 66

.33

.14 I

02C 02C

.610 NPSNM 14 CI TEC TEH

.610 SBACC 55 HII 02C 02C

.610 NPSNM 12 CI TEC TEH

.610 SBACC 65 HI 02C 02C

.610 NPSNM 12 CI TEC TEH

.610 SBACC 63 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 17 HI TEC TEH

.610 SBACC 67 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 19 HI TEC TEH

.610 SBACC 69 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 17 HI TEC TEH

.610 SBACC 67 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 19 HI TEC TEH

.610 SBACC 69 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 19 HI TEC TEH

.610 SBACC 67 HI TEC TEH

.610 SBACC 67 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 17 HI TEC TEH

.610 SBACC 67 HI TEC TEH

.610 SBACC 67 HI TEC TEH

.610 SBACC 67 HI TEC TEH

.610 SBACC 67 HI 11H 11H

.610 NPSNM 107 HI 11H 11H

.610 NPSNM 107 HI 02C 02C

.610 NPSNM 12 CI TEC TEH

.610 SBACC 67 HI 02C 02C

.610 NPSNM 12 CI TEC TEH

.610 SBACC 67 HI 02C 02C

.610 NPSNM 12 CI TEC TEH

.610 SBACC 69 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 17 HI TEC TEH

.61.0 SBACC 67 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 17 HI TEC TEH

.610 SBACC 67 HI TEC TEH

.610 SBACC 67 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 19 HI TEC TEH

.610 SBACC 69 HI 02C 02C

.610 NPSNM 12 CI TSH TSH

.610 NPSNM 19 HI TEC TEH

.610 SBACC 69 HI P1 11C 1

09H 31.40 1

10C 20.11

.96 0

PCT 17 P2 AV4

.00 S-

+ -------

+

+-

+

+------

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+---+.----+----+----+----

+------

-+-

+......---

2 ST Max

SG - D COLD LEG APPENDIX 12.8 PLUS POINT PROGRAM Braidwood 2 A2R14 CDE 20091001 10/23/2009 14:04:03 S.

+ - -----------

+

+

+

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI I-...-

+.....

+----+

+--

+.

+---

÷ 42 93 42 93 43 93 43 93 42 94 42 94 NDD NDD NDD 9.02 182 DNG NDD NDD 02C 02C

.610 NPSNM TEC TEH

.610 SBACC 02C 02C

.610 NPSNM TEC TEH

.610 SBACC 02C 02C

.610 NPSNM TEC TEH

.610 SBACC 12 C

67 H

12 C

67 H

12 C

69 H

P1 01H 15.85

+ ---------

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+---

+....

+----------+--

-+---+--+-+

-'---+...-

+----....

Tubes: 38 Records: 102 ST Max 3

Attachment B.4 Tubes Containing Secondary Side Foreign Wear

SG - A DAMAGED BY FOREIGN OBJECTS Braidwood A2R14 CDE D5 a 83 PLUGGED TUBE X

4 TUBE DAMAGED BY FOREIGN OBJECTS 110 105 100 95 90 85 80 75 70 oo00oooo90oo00o(P00o0

o00,

.. t f

.+.

65 60 55 50 45 40 35 30 25 20 15 10 0000 0 0

0000T0000 000 0

0

-O O

I F....

000 am.

0[

.... I..

-.00o 5

ooo.....

i.

.I.

0 0

45 0

D-...

T 0 xT 013-.

x*

00.[]

0 0

..... I...0 aa...

a......

0 0

0.....

.0....

.0 0

0 o...,.._

I

..T. o~ o. : :

= === j*

= = :: : :: :_.. :.

45 40 35 35 30 25 20 0.0.

00 00.

0.a 00..

a.3.

,°0(

'00.

0 0

0 0

0 0

0 0

ax X" 00()0...

0(

00 0.

0 0

0 0

0 0

0 0

00

-00

  • 00 98-.--o-0.,

)00.

0.,

00-.

)0.°..

°°0

(

.. *00(

,,-0 0

0,,,

.0...

oooobooood

( )O000oOo000.

~

~

0,,

°.°00 0

)0 o00

.0

.00 0'

°0 30 25 O0000 000o o oo0000 o

o00000000(

)O

.0

'0 1b 10 5

0..........................................

[

.... i

[........

i....

[....

[

i

[....

i........

i....

i....~

0o T --

T---

::1,*,

.........oo..... *...

. I..

0o 0

... T 0

o

........ T 00 T..

i....

......... *o o T0

.T

...T I.......................

I 00 I....

0 00.I I

I


I

. I "

15 5

0,-

0000

,,,0 10o :::: : :0::

70 65 60

I-:::!

110 105 100 95 90 85 80 75 55 50$0000 4

4 0 35 320 15 00 0000 55 50 45 40 35 30 25 20 15 1A 5

Westinghouse Electric Company LLC - ST Max 10/22/2009 20:14:50

SG -

A DAMAGED BY FOREIGN OBJECTS Braidwood 2 A2R14 CDE 20091001 10/22/2009 12:51:37

+----+---

+-+..--

.---. +----+---+.----.+--

-+

  • +...

+

+....----.-

+......

+--+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+..----.-----

+--"...---

+------------+---+....

+

.+

+.....

+

+......

+--+

42 22

.11 272 PCT 14 2

02C

.72 02C 02C

.610 NPSNM 6

Cl 2008/04/01 42 22 RBD 02C 02C

.610 ZPSNN 12 Cl 2008/04/01 42 22 NDD 03C 03C

.610 ZPSNN 16 Cl 2008/04/01 42 22

.08 87 VOL P4 02C

.65 02C 02C

.610 ZPSNN 16 Cl 2008/04/01 42 22

.11 249 PCT 14 2

02C

.67 02C 02C

.610 ZPSNN 16 Cl 2008/04/01 42 22 NOD TEH TEH

.610 ZPSNN 31 HI 2008/04/01 42 22 1.99 73 MBM 6

06C 4.55 TEC TEH

.610 ZBAZC 79 HII 31 52

.25 264 PCT 26 2

01H

.43 01H 01H

.610 NPSNM 103 HI 2008/04/01 31 52 NOD TEH TEH

.610 ZPSNM 25 HI 2008/04/01 31 52 3.31 191 ONG P1 11H 9.34 TEC TEH

.610 ZBAZC 85 HI 2008/04/01 31 52 3.85 188 ONG P1 11H 10.64 TEC TEH

.610 ZBAZC 85 HI 2008/04/01 31 52 5.09 188 ONG P1 11H 11.94 TEC TEH

.610 ZBAZC 85 HII 30 53

.07 91 PCT 9

2 01H

.55 01H 01H

.610 NPSNM 113 HI 2008/04/01 30 53 NOD TEH TEH

.610 ZPSNN 27 HI 2008/04/01 30 53 3.09 64 MBM 6

09C 11.95 TEC TEH

.610 ZBAZC 87 HI 2008/04/01 30 53 1.71 65 MBM 6 09C 18.78 TEC TEH

.610 ZBAZC 87 HI 2008/04/01 30 53 1.32 69 MBM 6

09C 23.36 TEC TEH

.610 ZBAZC 87 HII 32 53

.12 90 PCT 14 2

01H

.36 01H 01H

.610 NPSNM 113 HI 2008/04/01 32 53 NOD TEH TEH

.610 ZPSNN 27 HI 2008/04/01 32 53 NOD TEC TEH

.610 ZBAZC 87 HI

+--------+

÷---

+----+.---+....--..+-

+-

+--+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+.----.----.----+.."

+----+---+-

+-- --

+

---+

.----- +-.....+......+--

Tubes: 4 Records: 20 1

ST Max

SG - B DAMAGED BY FOREIGN OBJECTS Braidwood A2R14 CDE D5 o 49 PLUGGED TUBE X

6 TUBE DAMAGED BY FOREIGN OBJECTS 110 105 00 95 90 BUD[

130 -

85 80 75 1oo000000ooooo000

13.

70 65 60 55 50 45 40 35 30 25 20 15 1A 0

oooo0,ooo 0o opooXXoooo0oooooooo,ooooa 0

i0...o o....

.... T

.... T.

..... °=

0 oIo I

.... T............

am° 0 o0....

....T " 13 45 45 35 30 25 20 15 10 5

1 1 0

I 0

  • 00 "° a o

.T.

.T...

.00 0131100..0 I....

I o 13.oo.

0............

0...

0 0.

0. 00.............

.. 0

0.............

0 0......

I....0 0*

00..

0 (C,-0

(

1 0 0

.0 0*.

-0 o................ T o...

o.o.....oo..........

?

1 4 I4 V a

....w.4.

,o 0...o........

........o.......... o o+.......Tt.

.o

.o.0

~.... i:::::::i::-

0 0.

~.

. o.V.V 00 000...0 000 000.........

0

............01 4... O 00..

oo o...

00...

° I,.

I,,

1,

°

.0 0 oo 0......

t T

I 0

0 0

0...........

o T

(D-o................................................................................

0.

0 o

0 4

0 o

0 0

0

00.

l 0

T 0

m.......7**

000O 00 O 000 0000 0000 0

.T TO....

.T..

.T..

T....

... I....

.... T......... T...

o...

)0..

13 00 0 :

0 0 00 0 0 0 0.............

o........

T..

.. +.....

!X 0

..I...

... I "::I:....::..o oo.

TT'1......

°; +...... "....................

°° °.......i.........

I+

..0

....[....I....

.I...

o o..

.o o....

o T............

.. o o

.o o00 oo

.o o..

o....

0 0.

0 00 0 0 I

a..

o0 oo....

T.....

I

...i....

..i....

I I

... T....

0.

° 35 25 15 10 5

T.~... T....

.. T..

0..

  • °
  • °*

I....

T..

000016 106 00 0 009 0

0 000085 0008 0075 110 105 100 95 90 85 80 75 I

0000oP0000(

I T.... T.... i.

,0000o0000000000?000000000 25 26 15 16 5

000000oooo(o000P)000000)

O0000O00 0OOOO0 70 65 66 55 50 45 46 35 30 Westinghouse Electdc Company LLC - ST Max 10/22J2009 20:22:51

SG -

B DAMAGED BY FOREIGN OBJECTS Braidwood 2 A2R14 CDE 20091001 10/22/2009 23:47:20

+--------.

+-----

+÷------

-+


+-

+......

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+.

+..

+

+..

+

+

-+

4 4

+

13 38 NOD TSH TSH

.610 NPSNM 1

HI 13 38

.62 170 DFI 1

05H 34.98 TEC TEH

.610 ZBAZC 53 HI 13 38

.20 128 DFS 1

08C 3.52 TEC TEH

.610 ZBAZC 53 HI 13 38 TBP 2

07H 07H

.610 NPSNM 113 HI 13 38

.10 88 SVI P4 07H

-. 70 07H 07H

.610 NPSNM 113 HI 13 38

.15 89 PCT 18 2

07H

-. 70 05H 07H

.610 NPSNM 113 HI 49 51

.22 71 VOL P4 TSC

.55 TSC TSC

.610 NPSNM 4

Cl 49 51

.24 76 PCT 24 2

TSC

.58 TSC TSC

.610 NPSNM 4

Cl 49 51 2.69 179 DNT P1 AV3

-. 06 TEC TEH

.610 ZBAZC 63 HI 49 51

.28 119 DFS 1

TSC

.65 TEC TEH

.610 ZBAZC 63 HI 49 52

.25 77 PCT 25 2

TSC

.36 TSC TSC

.610 NPSNM 4

CI 49 52

.18 74 VOL P4 TSC

.38 TSC TSC

.610 NPSNM 4

CI 49 52

.47 84 PCT 37 2

TSC

.94 TSC TSC

.610 NPSNM 4

CI 49 52

.40 82 VOL P4 TSC

.96 TSC TSC

.610 NPSNM 4

CI 49 52 2.66 181 DNT P1 AV2

.00 TEC TEH

.610 ZBAZC 61 HI 49 52 2.89 179 DNT P1 AV3

-. 10 TEC TEH

.610 ZBAZC 61 HI 49 52 2.20 179 DNT P1 AV4

.00 TEC TEH

.610 ZBAZC 61 HI 49 52

.17 107 INR 1

TSC

.72 TEC TEH

.610 ZBAZC 61 HI 49 52 1.02 146 DFS 1

TSC 1.30 TEC TEH

.610 ZBAZC 61 HI 30 56 NOD TSH TSH

.610 NPSNM 5

HI 30 56

.16 56 DSI P1 07H

-. 63 TEC TEH

.610 ZBAZC 61 HI 30 56 TBP 2

07H 07H

.610 NPSNM 111 HI 30 56

.10 76 SVI P4 07H

-. 77 07H 07H

.610 NPSNM 111 HI 30 56

.11 281 PCT 15 P1 07H

-. 74 07H 07H

.610 NPSNM 111 HI 21 65

.22 51 DSI P1 05H

-. 63 TEC TEH

.610 ZBAZC 65 HI 21 65 TBP 2

05H 05H

.610 NPSNM 111 Hi 21 65

.28 263 SVI P4 05H

-. 64 05H 05H

.610 NPSNM 111 HI 21 65

.37 264 PCT 34 P1 05H

-. 63 05H 05H

.610 NPSNM 111 HI 19 67 NDD TSH TSH

.610 NPSNM 7

HI 19 67

.41 158 DFI 1

05H

-. 88 TEC TEH

.610 ZBAZC 65 HI 19 67 TBP 2

05H 05H

.610 NPSNM 111 HI 19 67

.15 92 SVI P4 05H

-. 79 05H 05H

.610 NPSNM 111 HI 19 67

.17 94 PCT 19 2

05H

-. 78 05H 05H

.610 NPSNM 111 HI

+----+----

+

+----+------

+-

+

I ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷-


+----+--

++---+----+-----+----

+----+

+. -

Tubes: 6 Records: 33 1

ST Max

SG - C DAMAGED BY FOREIGN OBJECTS Braidwood A2R14 CDE D5 X

1 TUBE DAMAGED BY v(RE[G2f OBJECTS a 65 PLUGGED TUBE 10 105 100 95 90 85 80 75 70

  • 65 60 55 50 45 40 35 30 25 20 15 10 00000000000 000000000000"0000000000 0

T....

00" t

7o00 0..

0-,a T -0 5

45 45 00.

00..

00*

00.

00-

)0...

0((O T....

. a

... 13

... 13.

I0 0,

0 0.

01I O

a...

°°....

S.... T....

0-0

.00 o00 0(

i 40 p.

f.

vv

°' ":

I: OOT"

°....

.... t -.... i'°')°°T...

'0

,0

,0 0.... ý..o

10...
00. 0 0

t3Q-0 0)1 00.. *0.-00 35 n

25 00001...

0.

00.t....

O 0T......

0 o°"'...... T.....

0.......

.... I.....

-00 T.

.0.......

)00 a.

i

'0 0

,0 0

-0 0

0 0

0 0

0 0

0 0

0 0

.--ooQ0....

.... T..

0....

0.....

T..

)0000(000006,-...

0 O1

.... °

....° 0....

.*°

°.....

000O000 0 000 0ý()00001 0000(,0000o(

S....

0 1000:

.... L "

0(

(

0....

.0...

T'00 i

~....oo S00.0

.... 000 00!

..T...........

T°"

.I 30 01 0

1::::

tiiiit ii~ ii....

i T*.°, °,,

15 10 5

0*

0.

00.

0..

I I

00..

.000(

0000, i

°.0

.T T

000.*

...*.... *........o 00 0.....

o0 o

.:... 0...

j T0o......

......C T....

T....

0 00......................................................

I o

I '............I I

........t

.. I,..

..*....o

  • ---1

-"~

~~

10 5

0°.° 0°.° 0*00 0000 T.........

° 0000(3C000000000(ooý00 110 105 100 95 90

.00 oo I....

T....

so 45 40

° T0...

00000 5

0000000000000000000 35 30 25 20 15 10 5

000o*o00o00o000(

85 80 75 1000 090000-70 65 60 55 Westinghouse Electdc Company LLC - ST Max 10(2212009 20:26:02

SG - C DAMAGED BY FOREIGN OBJECTS Braidwood 2 A2R14 CDE 20091001 10/22/2009 23:51:37 S

+--------

I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+---------

10 3

NOD TSH TSH

.610 NPSNM 11 HI I

10 3

.41 164 DFI 1

08H

-. 90 TEC TEH

.610 SBACC 47 HI I

10 3

TBP 2

07H 08H

.610 NPSNM 117 HI I

10 3

.17 108 PCT 20 2

08H

-. 98 07H 08H

.610 NPSNM 117 HI I

10 3

.14 88 SVI P4 08H

-. 82 07H 08H

.610 NPSNM 117 HI

+----.----.----.----.----.+

+----+--+

4 I ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+--------------+----+..------------÷

+--------+-+-+-

Tubes: 1 Records: 5 1

ST Max

SG - D DAMAGED BY FOREIGN OBJECTS Braidwood A2R14 CDE D5 a 26 PLUGGED TUBE X

2 TUBE DAMAGED BY FOREIGN OBJECTS

.10 105 100 95 90 85 80 75 70 65 O

1 1

1 1000OOOO(00000000000$0000 0...

60 55 50 45 0T 010T 0 0000q~~oOOO

, 0 o.o...ot....t....

00

,a O

o 40 QOOOO 35 30 25 20 15 10 1 0000

°'

D0

°.° 00 5

t0 t

00..1..............

I::::OI I::::

i t

v 45 40 35 30 25 20 15 0o I.......

I 00o 0

00 Ii t

0._.

00...........'...

e...

+....

  • .o.0...0..

I....

.o 0.........

o

o.

0 0 0........

0 0..

I

. 0

.0..

0 0........

oo.

. 0 )......

0.......

0 1.

t0 00.....

.0...

. -0" 0....

I o,

0 0 0.......

0..........

.1 0000 0

00...

I.

o.

o>o o.) 0 I oo o..

1 o....

0 0 '.

"..i 0

0 0.

0

0. 0 0 o 0 0 o 00...... t)....

0 0 T0..

)....

... I T

oo.I

.. o

.t 0....

+!I.....

+°~ ~ ~

~

~

~

~

~

~

~

~~

~~~~~~.....

0

..+.... ::

.. +.........

i++,::!::::!_

o.

T

°..

............ Z Z I1 1 1 0

oo..

.t.

.T..

o o !.

..i.

T....

0

..t...I ° 0o

... o o..

..o o

..o o

I 1 -

1*: 1.......... o o......

o0 000'0..............

... ("OO~*.

I~.....

0.,l.

i...OT I

I I

1 o~~~

~

....o o 0 0....

..T...

0..

t.

c"

.................()...... 1 o3 00....

,I.

...)

00 o.-

T...

T.....

.T:

...... :::,. o s o.

t..

I

... i I

' I I

1..

45 40 35 30 25 15 5

5 0000 0~~

0000 10 105 100(P 110 105 100 o0000 0 o, oooo0 0000000' O

000o00 0

000 90 85 80 75 70 65 60 55 50 45 40 0

p0000 95 (00o0000(poooo 35 30 o;ooo(qPoooopoooa 0;oooopo ooo 25 20 15 10 5

Westinghouse Electdc Company LLC - ST Max 10/2212009 20:28:38

SG - D DAMAGED BY FOREIGN OBJECTS Braidwood 2 A2R14 CDE 20091001 10/22/2009 11:32:08

+....----4-----------

4-----

-+

4-

+--..----.+-

+-

4----

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+---

+-------------------------+

+-+..

+-

4----

31 48

.18 269 PCT 19 2

O1H

.48 01H O1H

.610 NPSNM 21 HI 2008/04/01 31 48 NOD TEH TEH

.610 ZPSNN 25 HI 2008/04/01 31 48

.26 94 DSS P1 01H

.41 TEC TEH

.610 ZBAZC 77 HI 2008/04/01 31 48

.04 83 VOL P4 01H

.39 01H 01H

.610 ZPSNN 133 HI 2008/04/01 31 48

.15 273 PCT 19 2

01H

.48 01H 01H

.610 ZPSNN 133 HI 36 61

.14 294 PCT 16 2

TSH

.02 TSH TSH

.610 NPSNM 21 HI 2008/04/01 36 61 NDD TEH TEH

.610 ZPSNN 47 HI 2008/04/01 36 61 NDD TEC TEH

.610 ZBAZC 79 HI

+-----

-+

-+

÷...+

.---- +.. *---

+

÷ ---

+..----+-.....+-

4-

+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----+-

-+---

+----+---+--

-+..--------

---+----

+----...----.-.-..----

Tubes: 2 Records: 8 1

ST Max

Attachment B.5 Tubes Containing Anti-Vibration Bar Wear

SG - A ANTI-VIBRATION BAR WEAR INDICATIONS Largest Percent Indication Per Tube Braidwood A2R14 CDE D5 a

83 PLUGGED TUBE 1 1'7 J, 9%

2 61 20% to 29%

3 35 30% to 39%

110 105 100 95 90 1

1 1

1 1

85 80 75 70 100000000000000000C 65 60 j.0000(0 55 50 45 40 o000o0Qoooo0o001 Qoo000 35 30

  • )00000I 25 20 15 10 0O.0...

200 0

.3 " 1 0

am 01....

7....

I....

l-

-2200 I....

f

..z.-

1 o100 0

45 45 40 35 30 25 Sa..

  • .1...

a.a T

.013 lo.

0-0 0333 1.313 13 21-.21 2

.3 -.

3 o....

.. 2.

1123 02

.I a33-u ~- - - 933 a '1 4-02 a32 L-u 2-.n-I-

I...-.

~--..

-+------

0 03 323.-.-

000 02202231 2.

3 T

2 03 0

oo0,- o.

; !: T 1o o*.,

0

.*... o.. o 31-13 2-O oo.

1..1 T' "

0 o.*

. 20 1.12 O.......

0 ]0....

I....

2.

1100... 1.1 3 0oo

.0 -

2..

Mo......

00.........

0 0o.......

00 0 1 I

I o

0 0

0 0

00.11..

00.....'..'.......0 0

o.

i..

o 0

0.

I o.............................................

.......*.......o ot

.... I.....,....

00..t.

.i o*...

.1...

0. o

.[.............

T'

~~~~~~......

.o.o....

T....

T

....T l..

00...

13..............................

02o 00...

21 O.2 o.

.o I

T e-

.. o *o G

o 00.....................

00000 0000 00000 0000....

2..........0.o...0.0 3 "0.:I..

00 l) :

T:

0..

. " " T '

T....

°° ° °°0°°

° ° ° °....

. T.

T..

.... oo T......

0.00....

0.

0°....

...oo

.t...:!

!i : !: : i ! i : !

+ ::::I o...

.T....

o*.o*.

77.7

: 7 7 :...

4 4

1 no.

T...

o i ° *.

C 35 30 20 15 15 5

5 0...

0...

0.--

90 o0o0()o000oo 00o000oo0000, 110 105 100 95 ao00o00000000o00000(o0004)0000 oooaoo 00oqo0000(

85 80 75 70 65 60 55 50 45 40

,ooooqomo a b0a00o0000o0000o0000o0000o 25 20 15 10 5

35 30 Westinghouse Electnc Company LLC - ST Max 10/2212009 20:14:38

SG -

A ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2RI4 CDE 20091001 10/2212009 12:51:30

+.........----

+----+----.+..----.------.----4----.

+

-+

+-

+-

+-..+..--.

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT POIA PTYPE CAL LI I-------

4"-+---.--------.

+-

4 26 26 26 26 30 29 28 30 33 34 34 34 36 36 36 38 38 38 38 39 39 39 39 39 39 39 39 39 39 39 39 30 38 38 38 40 40 41 41 40 40 40 40 36 38 38 40 40 8

8 8

10 12 13 13 13 14 14 14 16 18 18 20 20 20 20 20 20 20 20 21 21 21 21 22 22 23 23 24 24 24 24 24 24 24 24 25 25 25 25 26 26 26 26 26 2.23 1.03 1.48

.75

.76 1.09

.78 1.28

.81

.92 1.26 1.23 2.48 1.28 1.11 1.17 2.25 1.59 2.30 2.08 1.22 3.35 1.48

.97 2.94 1.50

.84 1.09 1.67 4.13 2.87 1.07

.98 1.68 1.70 3.30

.76 1.77 1.80 1.20 1.97 2.94

.55

.94 1.05 2.54

.79 3.05 0

PCT 28 0

PCT 18 0

PCT 23 0

PCT 15 0

PCT 12 0

PCT 19 0

PCT 11 0

PCT 16 0

PCT 11 0

PCT 15 0

PCT 19 0

PCT 19 0

PCT 30 0

PCT 19 0

PCT 19 0

PCT 20 0

PCT 28 0

PCT 24 0

PCT 29 0

PCT 27 0

PCT 20 0

POT 34 0

POT 23 0

PCT 14 0

PCT 31 0

PCT 18 0

PCT 11 0

PCT 19 0

PCT 24 0

PCT 37 0

PCT 30 0

PCT 19 0

PCT 18 0

PCT 24 0

PCT 25 0

PCT 34 0

PCT 15 0

PCT 25 0

PCT 25 0

PCT 15 0

PCT 24 0

PCT 31 0

PCT 9

0 PCT 17 0

PCT 19 0

PCT 30 0

PCT 15 0

PCT 33 P2 AVI P2 AV2 P2 AV4 P2 AV2 P2 AVI P2 AV3 P2 AV2 P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV3 P2 AV2 P2 AV2 P2 AV3 P2 AVi P2 AV2 P2 AV3 P2 AV4 P2 AVI P2 AV2 P2 AV3 P2 AV4 P2 AV1 P2 AV2 P2 AV3 P2 AV4 P2 AVi P2 AV2 P2 AV2 P2 AV3 P2 AV4 P2 AVI P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV1 P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV2 P2 AV3 P2 AV2 P2 AV3

.00

-.05

-.10

.00

-. 03

-.08

.00

.03

.00

.03

.03

-.03

.00

.00

.03

. 18

-. 10

.00

.10

.18

.00

-.23

-.03

-. 24

.08

.05

-.03

.00

.03

.00

.18

.00

.00

.00

.05

.00

-.03

-.03

-.08

-.03

-.08

.13

.13

.03

.00

-.25

.00

-.25

.13 TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI I

TEC TEH

.610 ZBAZC 43 HI I

TEC TEH

.610 ZBAZC 41 HI I

TEC TEH

.610 ZBAZC 43 HI I

TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZO 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZO 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZO 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZO 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZO 43 HI TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZO 43 HI TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZO 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZO 41 HI TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZO 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 43 HI 42 26

.76 0

PCT 15 P2 AV2

+----.

+-


.-----+--.---...+....+.

-+

.+

---.- +-......

+..-

+

INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENOT PDIA PTYPE CAL LI

+-----+...

4

+- ---

+---

+

-+r

-+

4-- +

1 ST Max

SG - A ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 12:51:30 "1"-

+"------

++----

+----4-----+-

+---

+--+....

+-

+---+

+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+----+-

+----+------------------+-

.+..

+

-+"--I--

42 26 1.45 0

PCT 22 P2 AV3 38 38 30 38 38 42 42 42 40 40 47 47 36 36 36 38 38 41 42 42 47 47 38 38 38 40 40 40 40 38 40 46 40 47 47 29 38 36 41 41 42 40 41 45 27 27 28 28 28 28 28 28 29 29 29 29 30 30 30 30 30 30 30 30 30 30 31 31 31 31 31 31 31 33 33 33 34 34 34 35 35 36 36 36 36 37 37 37

.68 1.50

.82

.79 1.54

.83

.94

.79 2.28 1.98 2.08 1.95 1.37

.91 1.00 1.52 1.94

.82

.69

.90 1.22

.74 1.88 2.91

.94 1.11 1.93 2.46 1.30 1.18

.86 1.39 1.07

.69

.78 1.26 2.54

.71 2.25 4.42

,95 1.15 2.17 1.42 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 229 PCT 0

PCT 0

PCT 11 20 16 16 24 17 18 16 25 23 24 23 23 18 19 23 27 17 15 17 21 15 22 30 13 15 22 27 17 15 12 18 19 15 16 21 27 15 29 38 18 15 24 18 P2 AV2 P2 AV3 P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV4 P2 AVI P2 AV2 P2 AV3 P2 AV4 P2 AV3 P2 AV3 P2 AV4 P2 AV2 P2 AVI P2 AV4 P2 AV4 P2 AV2 P2 AV2 P2 AV2 P2 AV3 P2 AV3 P2 AV2 P2 AV2 P2 AV2

.00

-.15

.00

.00

-.13

-.03

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.03

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 TEC TEH

.610 ZBAZC 43 HI TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZC 41 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEO TEH

.610 ZBAZO 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEO TEH

.610 ZBAZO 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZO 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZO 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZO 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEO TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZO 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 45 HI TEO TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 47 HI TEC TEH

.610 ZBAZC 45 HI TEC TEN

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI TEC TEH

.610 ZBAZC 45 HI 45 37 2.83 0

PCT 29 P2 AV3

+...-----.+---

-+ --

-+

+

+

+

..---- +----.

+-'1--..---.....+

+.....----- -

+-......

+...-...--

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+- ------

+

+----+----+

+---------

+----.--

+.----...--

+.-........

.+.-

+-+

2 ST Max

SG -

A ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2RI4 CDE 20091001 10/22/2009 12:51:30

+

+-+

-+-+--

+----+----+----+----

+-

-+

+......

+--+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----

+-

-+..---

+-

+--

-+--

-+..----+-----------+-

-+--

+

-+

-+

31 38

.99 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 47 HI 31 38 1.52 0

PCT 24 P2 AV3

.00 TEC TEH

.610 ZBAZC 47 HI I40 38 1.38 0

PCT 23 P2 AV

.00 TEC TEH

.610 ZBAZC 47 HI 40 38

.91 0

PCT 18 P2 AV2

.00 TEC TEH

.610 ZBAZC 47 HI 40 38 1.32 0

PCT 22 P2 AV3

.00 TEC TEH

.610 ZBAZC 47 HI 40 38

.81 0

PCT 16 P2 AV4

.00 TEC TEH

.610 ZBAZC 47 HI 41 38

.71 0

PCT 15 P2 AV2 1.83 TEC TEH

.610 ZBAZC 47 HI 30 39

.97 0

PCT 13 P2 AV2

.00 TEC TEH

.610 ZBAZC 45 HI 30 39 1.55 0

PCT 19 P2 AV3

.00 TEC TEH

.610 ZBAZC 45 HI 30 39 1.26 0

PCT 16 P2 AV4

.00 TEC TEH

.610 ZBAZC 45 HI 41 39 1.28 0

PCT 16 P2 AV2

.00 TEC TEH

.610 ZBAZC 45 HI 41 39 1.11 0

PCT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 45 HI 41 39 1.42 0

PCT 18 P2 AV4

.00 TEC TEH

.610 ZBAZC 45 HI 124 40

.56 0

PCT 12 P2 AVi

.00 TEC TEH

.610 ZBAZC 31 HI 24 40 1.29 0

PCT 20 P2 AV2

.03 TEC TEH

.610 ZBAZC 31 HI 24 40 1.55 0

POT 22 P2 AV3

-. 19 TEC TEH

.610 ZBAZC 31 HI 40 40

.84 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 47 HI 45 40

.90 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 47 HI 26 41 1.74 0

PCT 25 P2 AV3

.00 TEC TEH

.610 ZBAZC 47 HI 30 41

.71 0

PCT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 47 HI 39 41 1.78 0

POT 21 P2 AV2

.00 TEC TEH

.610 ZBAZC 45 HI 45 41 1.14 0

PCT 15 P2 AV2

.00 TEC TEH

.610 ZBAZC 45 HI 49 41 1.18 0

POT 15 P2 AVi

.00 TEC TEH

.610 ZBAZC 45 HI 37 42 1.03 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 47 HI 37 42

.98 0

POT 19 P2 AV3

.00 TEC TEH

.610 ZBAZC 47 HI 41 42

.86 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 47 HI 41 42 2.06 0

POT 27 P2 AV3

.00 TEC TEH

.610 ZBAZC 47 HI 40 43 1.49 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 45 HI 45 45 1.80 0

POT 24 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 HI 40 47 1.67 0

PCT 23 P2 AV2

-. 05 TEC TEH

.610 ZBAZC 49 HI 42 51 1.40 0

POT 20 P2 AV2

-. 05 TEC TEH

.610 ZBAZC 49 HI 45 51 1.07 0

PCT 17 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI 41 52

.76 0

POT 15 P2 AV2

.00 TEC TEH

.610 ZBAZO 51 HI 45 52

.75 0

PCT 15 P2 AV2

.00 TEC TEH

.610 ZBAZC 51 HI I45 55 1.54 0

POT 22 P2 AV2

.00 TEC TEH

.610 ZBAZO 49 HI 145 55 2.10 0

POT 26 P2 AV3

.15 TEC TEH

.610 ZBAZO 49 HI 42 56

.98 0

PCT 14 P2 AV2

.00 TEC TEH

.610 ZBAZC 53 HI 45 59 1.09 0

PCT 18 P2 AV2

.00 TEC TEH

.610 ZBAZC 55 HI 45 59 1.68 0

PCT 24 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI 20 60 3.23 0

POT 34 P2 AVi

.00 TEC TEH

.610 ZBAZC 63 HI 20 60 1.32 0

PCT 22 P2 AV4

.00 TEC TEH

.610 ZBAZC 63 HI 46 60 1.21 0

POT 16 P2 AVi

.00 TEC TEH

.610 ZBAZC 53 HI 46

.60 2.13 0

PCT 25 P2 AV2

.00 TEC TEH

.610 ZBAZC 53 HI 40 61 3.54 0

PCT 35 P2 AV2

.00 TEC TEH

.610 ZBAZC 55 HI

+----.....+-....+--....

++----+-....+-....+-...

4

+-

+-........--+4

-+-

+÷-

+-+

+-

I INSPDATE ROW COL VOLTS DEG IND PER OHN LOON INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-....+

+-....+-....+-....+--....

4

+-

+-........--+4

-+-

+-

+-+

+-

32 ST Max0PT 20 P

V

.5 E

E 60 B

9H 3

ST Max

SG -

A ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 12:51:30

+

+----+

+----+---------------

+---

+---

+-...+-..

INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Ll

+----

+----+----+

+----+----+--------

4+-

+

+--....--+

40 61 2.02 0

PCT 26 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI I45 61

.48 0

POT 10 P2 AVI 8

TEC TEH

.610 ZBAZC 55 HI 45 61

.83 0

PCT 15 P2 AV2

.00 TEC TEH

.610 ZBAZC 55 HI 45 61 3.47 0

PCT 34 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI 45 61

.86 0

PCT 16 P2 AV4

.00 TEC TEH

.610 ZBAZC 55 HI I42 62 1.20 0 POT 17 P2 AV3

.83 TEC TEH

.610 ZBAZC 53 HI I45 62 1.03 0

POT 15 P2 AV3

-.13 TEC TEH

.610 ZBAZC 53 HI 40 64

.75 0

PCT 12 P2 AV3

.03 TEC TEH

.610 ZBAZC 53 HI 45 64 1.13 0

PCT 15 P2 AV1

.00 TEC TEH

.610 ZBAZC 53 HI 45 64 3.80 0

POT 35 P2 AV2

.00 TEC TEH

.610 ZBAZO 53 HI 45 64 2.53 0

PCT 28 P2 AV3

.08 TEC TEH

.610 ZBAZC 53 HI I39 65 1.22 0

POT 20 P2 AV2

.00 TEC TEH

.610 ZBAZO 55 HI 39 65 2.14 0

POT 27 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI 45 65

.96 0

PCT 17 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI 36 66 1.82 0

PCT 23 P2 AV3

.41 TEC TEH

.610 ZBAZC 53 HI 40 66

.75 0

PCT 12 P2 AV2

-. 18 TEC TEH

.610 ZBAZC 53 HI 39 67

.87 0

PCT 16 P2 AVi

.00 TEC TEH

.610 ZBAZC 55 HI 39 67

.87 0

PCT 16 P2 AV2

.00 TEC TEH

.610 ZBAZC 55 HI 44 67

.78 0

PCT 15 P2 AVi

.00 TEC TEH

.610 ZBAZC 55 HI I39 68

.68 0

POT 11 P2 AVi

.15 TEC TEH

.610 ZBAZO 53 HI 40 68 1.55 0

POT 20 P2 AV2

.15 TEC TEH

.610 ZBAZC 53 HI 40 68

.94 0

PCT 14 P2 AV3

.26 TEC TEH

.610 ZBAZC 53 HI 41 68 1.10 0

PCT 16 P2 AV2

.15 TEC TEH

.610 ZBAZC 53 HI 41 68 2.87 63 POT 30 P2 AV3

.13 TEC TEH

.610 ZBAZC 53 HI 40 69

.82 0

PCT 15 P2 AVi

.00 TEC TEH

.610 ZBAZC 55 HI 41 69 1.00 0

POT 17 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI 39 70 2.07 0

PCT 25 P2 AV2

.08 TEC TEH

.610 ZBAZC 53 HI I39 70 1.01 0

POT 15 P2 AV3

-. 10 TEC TEH

.610 ZBAZO 53 HI I45 70 1.18 0

POT 17 P2 AV2

.03 TEC TEH

.610 ZBAZO 53 HI 45 70

.96 0

PCT 14 P2 AV3

.03 TEC TEH

.610 ZBAZC 53 HI 42 71

.80 0

PCT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI 43 71 1.39 0

PCT 21 P2 AV1

.00 TEC TEH

.610 ZBAZC 55 HI S43 71 2.32 0

POT 28 P2 AV2

.00 TEC TEH

.610 ZBAZC 55 HI 43 71 1.23 0

PCT 20 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI I

46 71 1.18 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 55 HI S46 71

.80 0

PCT 15 P2 AV4

.86 TEC TEH

.610 ZBAZC 55 HI I

39 72 1.58 0

PCT 21 P2 AV2

.13 TEC TEH

.610 ZBAZC 53 HI I

41 72 1.08 0

PCT 16 P2 AV3

.31 TEC TEH

.610 ZBAZC 53 HI 43 72

.87 0

PCT 13 P2 AV3

.15 TEC TEH

.610 ZBAZC 53 HI 47 72

.75 0

PCT 12 P2 AVi

.00 TEC TEH

.610 ZBAZC 53 HI I32 73 1.12 0

POT 16 P2 AVi

.88 TEC TEH

.610 ZBAZC 57 HI 32 73

.74 0

PCT 12 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 32 73 1.02 0

PCT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 32 73 179 0

PCT 13 P2 AV4

.00 TEC TEH

.610 ZBAZC 57 HI 37 73

.60 0

PCT 12 P2 AVi

.00 TEC TEH

.610 ZBAZC 55 HI

+-46 71-.80 PCT 15-P2--+

.86

+

+

+

+

+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOON INCHi INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-

+--+---+

+-..--+-÷

-+----....+

÷....-

-+---

+-....+-

÷-

+-

+-

4 ST Max

SG A

ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 COE 20091001 10/22/2009 12:51:30

+---+---+-------+--------+----+----+-------+-

I1--

--- +-"

+-

+-+

-+--+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----.

+

+---

+-

+----

+

÷ 4.------+.----+

+-

4.

2.03

.88

.75 3.95 3.61 2.00

.56 2.82

.97 1.08 2.73 1.13 1.15

.71

.79 3.02 1.19 1.01 1.60 1.96 1.72

.84 1.03 1.40 3.74 1.66

.64 1.10

.40

.89

.72

.91

.77

.95

.96

.93 1.04

.89 1.31

.71 1.85 1.76

.80

.70 1.19

.87 1.29 2.35 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0 PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 26 16 14 36 35 26 12 31 17 18 31 19 18 11 12 32 19 17 23 26 24 17 19 19 35 21 10 16 7

13 11 13 12 12 17 17 18 16 18 11 23 22 13 11 17 P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV3 P2 AV4 P2 AVI P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV3 P2 AVI P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV3 P2 AV4 P2 AVi P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV3 P2 AVi P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV2 P2 AV1 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV3 P2 AV1 P2 AV2 P2 AV3

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.03

.03

.00

.00

-.23

.00

.00

.00

.19

.13

.05

.31

.15

.08

.15

.05

.10

-. 18

-. 08

.00

-.03

.00

-. 18

-. 26

-. 26

.21

.05

.13

.15

.00

.00

.00

.00

.23

-.05 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC 55 HI 55 HI 55 HI 55 HI 55 HI 55 HI 55 HI 55 HI 55 HI 55 HI 55 HI 55 HI 59 HI 53 HI 53 HI 55 HI 55 HI 55 HI 55 HI 55 HI 55 HI 63 HI 63 HI 53 HI 53 HI 53 HI 53 HI 53 HI 53 HI 53 HI 53 HI 65 HI 65 HI 65 HI 55 HI 67 HI 67 HI 67 HI 53 HI 53 HI 53 HI 53 HI 57 HI 57 HI 57 HI 65 HI 65 HI 65 HI 33 37 77 77 25 78 25 78 29 78 34 78 37 78 39 78 39 78 40 78 40 78 41 78 31 79 31 79 31 79 0

PCT 13 0

PCT 18 0

PCT 27

+....

+

+.

+.+

~"

+..----+-

+-

+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-

-4.

4-

+-

~4.

-4...---

+----+-

+-

+-4.

+

5 ST Max

SG -

A ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 12:51:30

+----+

+----+----+----+

+---.--+

-+-----+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+.......--------+----...

+----.----.

+.-

-+-

+---+---+--

+---+

+....

+-

÷-

40 79 2.05 0

PCT 26 P2 AV2

.08 TEC TEH

.610 ZBAZC 59 HI 40 79 2.61 0

PCT 30 P2 AV3

-. 33 TEC TEH

.610 ZBAZC 59 HI 41 79 1.09 0

POT 18 P2 AVi

-.12 TE TEH

.610 ZBAZC 59 HI 41 79 1.26 0

PCT 20 P2 AV2

-. 08 TEC TEH

.610 ZBAZC 59 HI 41 79 2.32 0

PCT 28 P2 AV3

-. 23 TEC TEH

.610 ZBAZC 59 HI 40 B0 1.20 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 45 80 1.85 0

PCT 23 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 45 B0 3.04 0

POT 32 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 45 80 1.31 0

PCT 18 P2 AV4

.00 TEC TEH

.610 ZBAZC 57 HI 33 81

.70 0

PCT 32 P2 AV2

.00 TEC TEH

.610 ZBAZC 65 HI 34 81 1.52 0

PCT 23 P2 AV2

.00 TEC TEH

.610 ZBAZC 71 HI I37 81 1.06 0

POT 17 P2 AVi

-.08 TEC TEH

.610 ZBAZO 59 HI 37 81 2.87 0

PCT 31 P2 AV2

.15 TEC TEH

.610 ZBAZC 59 HI 37 81 2.48 0

POT 29 P2 AV3

.28 TEC TEH

.610 ZBAZC 59 HI 40 81 1.60 0

PCT 23 P2 AV2

-. 03 TEC TEH

.610 ZBAZC 59 HI 37 82 1.04 0

PCT 15 P2 AVi

.00 TEC TEH

.610 ZBAZC 57 HI 37 82

.92 0

PCT 14 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 40 82 1.77 0

PCT 23 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 40 82 1.03 0

PCT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 41 82 1.04 0

POT 16 P2 AVi

.00 TEC TEH

.610 ZBAZC 57 HI 41 82 3.92 0

PCT 36 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 41 82 2.24 0

PCT 26 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 41 82 1.30 0

POT 18 P2 AV4

.00 TEC TEH

.610 ZBAZC 57 HI 45 82

.61 0

PCT 10 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 45 82 1.09 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 36 83 1.13 0

PCT 18 P2 AV2

.00 TEC TEH

.610 ZBAZC 59 HI 40 83 2.41 0

PCT 28 P2 AVi

.05 TEC TEH

.610 ZBAZC 59 HI 40 83 2.16 0

PCT 27 P2 AV2

.03 TEC TEH

.610 ZBAZC 59 HI 40 83 1.40 0

PCT 21 P2 AV3

-. 18 TEC TEH

.610 ZBAZC 59 HI 40 83

.83 0

POT 15 P2 AV4

.13 TEC TEH

.610 ZBAZC 59 HI 39 84

.65 0

PCT 10 P2 AVI

.00 TEC TEH

.610 ZBAZC 57 HI 39 84 1.20 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 39 84 1.35 0

POT 19 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 40 84 1.06 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 41 84 1.27 0

PCT 18 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 39 85 1.21 0

PCT 19 P2 AV2

-. 08 TEC TEH

.610 ZBAZC 59 HI 39 85 1.74 0

PCT 24 P2 AV3

-. 10 TEC TEH

.610 ZBAZC 59 HI I41 85 1.26 0

POT 19 P2 AV2

.10 TEC TEH

.610 ZBAZO 59 HI 41 85

.98 0

PCT 17 P2 AV3

-. 10 TEC TEH

.610 ZBAZC 59 HI 38 86

.60 0

POT 10 P2 AVI

.00 TEC TEH

.610 ZBAZC 57 HI 38 86 1.62 0

PCT 21 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 38 86 1.21 0

PCT 17 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 39 86 1.39 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 39 86 1.07 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 36 87 1.07 0

PCT 18 P2 AV3

-. 10 TEC TEH

.610 ZBAZC 59 HI 38 87

.63 0

POT 12 P2 AV2

.18 TEC TEH

.610 ZBAZC 59 HI 39 87 3.84 0

PCT 36 P2 AV2

-. 03 TEC TEH

.610 ZBAZC 59 HI 39 87 1.04 0

PCT 17 P2 AV3

-. 13 TEC TEH

.610 ZBAZC 59 HI

+--

-+---+--...

+÷--.........---+-..+-÷

÷..

-÷-

+.-.÷+....+-

+-

+ -÷

÷-

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOON INOHi INCH2 BEGT ENDT PDIA PTYPE CAL LI 4-

+-----

+--+-+

+...+-....+

4

+

+-+-.....÷.. --

÷+

+ -÷

÷-

61 ST 1.6MPT 1a2xV 1

E E

.1 BZ 9H 6

ST Max

SG -

A ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2RI4 CDE 20091001 10/22/2009 12:51:30

+---+----

+

+----+----+----+---

+-----

+-

+-......+.....-.+--+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----.----.----------+-*

+-----+

+-

+--

-+

+..----+-....+-

+-

+ -+

40 87 1.29 0

PCT 40 87 4.15 0

PCT 40 87 1.07 0

PCT 40 87 1.03 0

PCT 41 87 2.75 0

PCT 41 87 2.38 0

PCT 33 88 1.05 0

PCT 36 88 1.09 0

PCT 36 88 1.22 0

PCT 40 88 2.73 0

PCT 40 88 2.01 0

PCT 40 88 1.13 0

PCT 47 88 1.27 0

PCT 36 89

.97 0

PCT 36 89 1.04 0

PCT 38 89 1.44 0

PCT 38 89

.98 0

PCT 40 89

.84 0

PCT 40 89

.92 0

PCT 41 89 1.23 0

PCT 42 89

.92 0

PCT 42 89 1.12 0

PCT 31 90 1.11 0

PCT 35 90

.70 0

PCT 35 90

.69 0

PCT 35 90 2.25 0

PCT 37 90 1.08 0

PCT 38 90

.59 0

PCT 38 90 1.31 0

PCT 38 90 1.54 0

PCT 39 90

.70 0

PCT 39 90 2.88 0

PCT 39 90 3.07 0

PCT 20 P2 AVI P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV3 P2 AV2 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV4 P2 AV4 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV3 P2 AV2 P2 AV3 P2 AV3 P2 AVl P2 AV2 P2 AV3 P2 AV2 P2 AVU P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV3

-. 03

-. 18

-. 08

-. 10

-.18

.00

.00

.00

.00

.00

.00

-. 24

.03

.05

-. 08

-.08

-. 13

-.15

-. 15

.18

.13

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00 TEC TEH TEC TEH TEC TEH TEC TEH TEC

.TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC 59 H

59 H

59 H

59 H

59 H

59 H

75 H

57 H

57 H

57 H

57 H

57 H

59 H

59 H

59 H

59 H

59 H

59 H

59 H

59 H

59 H

59 H

75 H

57 H

57 H

57 H

57 H

57 H

57 H

57 H

57 H

57 H

57 H

39 90

.91 0

PCT 14 P2 AV4

.00 TEC TEH

.610 ZBAZC 57 HI 41 90 2.96 0

POT 31 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 41 91 3.74 0

PCT 35 P2 AV2

-. 05 TEC TEH

.610 ZBAZC 59 HI 41 91 1.78 0

PCT 24 P2 AV3

-. 10 TEC TEH

.610 ZBAZC 59 HI 45 91 1.76 0

PCT 24 P2 AV3

.53 TEC TEH

.610 ZBAZC 59 HI I36 92 1.22 0

POT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 36 92 1.60 0

PCT 21 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 37 92 1.00 0

POT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 38 92 2.32 0

PCT 27 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 38 92 1.72 0

PCT 22 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 41 92 1.62 0

POT 21 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 41 92 3.78 0

PCT 35 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 44 92 1.06 0

PCT 16 P2 AV4

.00 TEC TEH

.610 ZBAZC 57 HI 37 93 1.24 0

PCT 19 P2 AV3

-.31 TEC TEH

.610 ZBAZC 59 HI

+-....+---+--

+--

+-

-+---+-....+--....

+--

-+-'-

÷-

+-

+4-....+-...

I INSPOATE ROW COL VOLTS DEG IND PER CHN LOON INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL L I

+....-

+-

-"+-

+

-+

4-.

+-....+

-....+

-....+-....+-

--+

+-

+-+

7 9ST Max

SG - A ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 12:51:30

+.........----+----.----.+..

-+-+----.----..+----+--

-+---

+

--+... ---

+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+........----+----+----..+

+----.----+----+---.

+--

-+

+----+ -......

+....-..

+......+-

38 93

.92 0

PCT 16 P2 AV2

-. 21 TEC TEH

.610 ZBAZC 59 HI 38 93 1.99 0

PCT 26 P2 AV3

-. 26 TEC TEH

.610 ZBAZC 59 HI I

41 93

.87 0

PCT 15 P2 AV1

.00 TEC TEH

.610 ZBAZC 59 HI 41 93 4.42 0

PCT 38 P2 AV2

.00 TEC TEH

.610 ZBAZC 59 HI 41 93 3.37 0

PCT 33 P2 AV3

.00 TEC TEH

.610 ZBAZC 59 HI 41 93

.94 0

PCT 16 P2 AV4

.00 TEC TEH

.610 ZBAZC 59 HII 43 93

.71 0

PCT 13 P2 AV4

.00 TEC TEH

.610 ZBAZC 59 HI 33 94

.64 0

POT 10 P2 AV2

.05 TEO TEH

.610 ZBAZO 73 HI 34 94 1.20 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 42 94

.86 0

POT 13 P2 AV4

.00 TEC TEH

.610 ZBAZC 57 HI 35 96 2.10 0

PCT 25 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 26 97

.93 0

PCT 14 P2 AV3

.02 TEC TEH

.610 ZBAZC 77 HI I33 98 1.27 0

POT 18 P2 AV2

.00 TEC TEH

.610 ZBAZO 73 HI 33 98 1.42 0

POT 19 P2 AV3

.00 TEC TEH

.610 ZBAZO 73 HI 34 98

.95 0

PCT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 28 99

.94 0

POT 17 P2 AV3

.00 TEC TEH

.610 ZBAZC 79 HI 33 99

.98 0

PCT 14 P2 AV2

.00 TEC TEH

.610 ZBAZC 73 HI 29 100 1.02 0

PCT 15 P2 AV2

.00 TEC TEH

.610 ZBAZC 73 HI 29 100 1.19 0

PCT 17 P2 AV3

.00 TEC TEH

.610 ZBAZC 73 HI S29 102 1.26 0

PCT 17 P2 AV3

.00 TEC TEH

.610 ZBAZC 73 HI I29 103

.89 0

POT 14 P2 AV1

.05 TEC TEH

.610 ZBAZC 77 HI 29 103 1.04 0

PCT 15 P2 AV3

.07 TEC TEH

.610 ZBAZC 77 HI I30 103 2.54 0

POT 28 P2 AV1

-. 10 TEC

  • TEH

.610 ZBAZC 77 HI 30 103 1.64 0

PCT 21 P2 AV2

-. 05 TEC TEH

.610 ZBAZC 77 HI 30 103 2.14 0

POT 25 P2 AV3

-. 15 TEC TEH

.610 ZBAZC 77 HI 28 104 1.12 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 79 HI 29 104 1.01 0

PCT 18 P2 AV1

.05 TEC TEH

.610 ZBAZC 79 HI 29 104 3.07 0

POT 32 P2 AV2

.00 TEC TEH

.610 ZBAZC 79 HI 29 104 3.30 0

PCT 34 P2 AV3

.00 TEC TEH

.610 ZBAZC 79 HI 27 105 2.18 0

PCT 26 P2 AV1

.00 TEC TEH

.610 ZBAZC 77 HI 27 105 1.73 0

PCT 22 P2 AV2

.00 TEC TEH

.610 ZBAZC 77 HI I27 105 1.21 0

POT 17 P2 AV3

.00 TEC TEH

.610 ZBAZC 77 HI 28 105 1.25 0

PCT 18 P2 AVI

.00 TEC TEH

.610 ZBAZC 77 HI 28 105

.70 0

PCT 11 P2 AV2

.02 TEC TEH

.610 ZBAZC 77 HI 28 105

.95 0

PCT 14 P2 AV3

.00 TEC TEH

.610 ZBAZC 77 HI I

25 106 1.21 0

PCT 12 P2 AV2

.00 TEC TEH

.610 ZBAZC 79 HI I

27 106 1.01 0

PCT 27 P2 AVI

.00 TEC TEH

.610 ZBAZC 79 HI 27 106 1.36 0

PCT 21 P2 AV2

.00 TEC TEH

.610 ZBAZC 79 HI 27 106 2.00 0

PCT 26 P2 AV3

.00 TEC TEH

.610 ZBAZC 79 HI 27 106 1.10 0

POT 19 P2 AV2

.00 TEC TEH

.610 ZBAZO 79 HI 27 107 2.48 0

PCT 26 P2 AV3

.00 TEC TEH

.610 ZBAZC 77 Hl 27 107 1.16 0

PCT 17 P2 AV4

.00 TEC TEH

.610 ZBAZC 77 HI 25 108 1.24 0

PCT 17 P2 AV4

.00 TEC TEH

.610 ZBAZC 77 HI 28 105 1.25 0

PCT 17 P2 AV4

.00 TEC TEH

.610 ZBAZC 77 HI 23 109 1.74 0

PCT 12 P2 AV4

.00 TEC TEH

.610 ZBAZC 77 HI 23 109 4.05 0

PCT 37 P2 AV4

.00 TEC TEH

.610 ZBAZC 77 HI 29 105 1.25 0

PCT 17 P2 AV4

.00 TEC TEH

.610 ZBAZC 73 HI

+----.....+---+---+--

+

+-....+--+---+-....+-

+..-+-

+

+-+-

+-+-

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOON INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+-

+

+---

+

+

+

-.... +

.+

+

.4

+--

+--+-

+-

Tubes: 203 Records: 374 8

ST Max

SG - B ANTI-VIBRATION BAR WEAR INDICATIONS Largest Percent Indication Per Tube Braidwood A2R14 CDE D5 a 49 PLUGGED TUBE i 22 O% to 19%

2 27 20% to 29%

3 9 30% to 39%

4 1 40% to 100%

110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 IMOOO(DOOOOOOOO()OOOO()OOO (PO O(POOOOPOOOOOOOOO000p0000 I

I I

5 OUO..........

0 0

j....

j... UP13 gat 001.:t.... t....

10 T....

  • o--

,::,'2

--,,, ~ o, 0

00.

131.*

3 45 48 35 45 25 00 0 0......

o0

° ° ii i i

°'...I...

  • I.

............00 0

I o2 00:

3T-....

{. -3

= )00 0......

~~-G-04 2~

0.......

0 02.

oo.o.--.

2..

2.

0 0

2

...0 0

)

0 0 0......oo.

32.......

oo.

..................I...

0".'°

°°

......00............00 00'1

...Ii.

................................ 100° o.0 0...........................

o....'I

.....T*

,"T....

o o

..2,

0 T

3 0

0 L".4 2-1.

I.........

0 0 -

2 1 0

I.........

30......

o 0.....

"o S..o*

o.......

2.....

0.

..I..

. T..

... T.

.. T.

o

... T i...

I..

.T...

0

....... 0 c

o-0 t

0 0 oo: -.

.t...

o

--. 0...

OO...........

10...

. o o...

o o*.

. T..

.I.

.I....

00 0 (0 0 (0 0 (0 0 0 0 0 *

  • I....

... 1--

T..T.

o o

.~...

o

.... I o ~ ~

~

o (*..........

T....

T I

o.

o o

.o ol..

o o.T

( O o..

i.

.. T.

.o

...I.

...........T...... T....o

=0.

e E) 0 0::

=

=

=

I 35 15 18 5

25 20 15 10 5

I I..

T.........T........

T....,'....

T...

68 48 28....

1.

60 55 50 45 40 35 30 25 20 15 10 5

0000 ooo00o000*oooooPooo00poooooo0000o0000o00000(oooo(oooo, 110 105 100 95 90 85 80 75 70 65 Westinghouse Electric Company LLC - ST Max 10/22/2009 20:22:39

SG - B ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2RI4 CDE 20091001 10/22/2009 13:37:00

+....

+-

+....

+

4-.

+-...+---+----.

.+-.....+....----

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+..----+...

+...

+-..-----.-.

33 14 3.40 0

PCT 31 P2 AV2

.00 TEC TEH

.610 ZBAZC 53 HI 33 14 1.53 0

PCT 21 P2 AV3

.00 TEC TEH

.610 ZBAZC 53 HI 35 15 2.05 0

POT 25 P2 AV2

.17 TEC TEH

.610 ZBAZO 55 HI 35 15 4.42 0

PCT 38 P2 AV3

.00 TEC TEH

.610 ZBAZC 55 HI 35 15 1.97 0

PCT 24 P2 AV4

.14 TEC TEH

.610 ZBAZC 55 HI 40 22 1.95 0

PCT 24 P2 AV2

.05 TEC TEH

.610 ZBAZC 53 HI 40 22 1.18 0

POT 18 P2 AV3

-.05 TEC TEH 610 ZBAZO 53 HI 38 24

.93 0

PCT 16 P2 AV2

.00 TEC TEH

.610 ZBAZC 53 HI 41 26 1.58 0

PCT 21 P2 AV2

.00 TEC TEH

.610 ZBAZC 53 HI 43 30 2.29 0

PCT 26 P2 AV2

.00 TEC TEH

.610 ZBAZC 53 HI 43 32 1.42 0

POT 20 P2 AVi

.00 TEC TEH

.610 ZBAZO 53 HI 43 32 1.53 0

PCT 21 P2 AV2

.08 TEC TEH

.610 ZBAZC 53 HI 28 34 1.04 0

POT 16 P2 AV2

-.05 TEC TEH

.610 ZBAZO 53 HI 39 34

.97 0

PCT 16 P2 AVi

.00 TEC TEH

.610 ZBAZC 53 HI 37 36 1.05 0

POT 17 P2 AVi

.10 TEC TEH

.610 ZBAZC 53 HI 37 36 1.31 0

PCT 19 P2 AV2

.16 TEC TEH

.610 ZBAZC 53 HI 37 36 1.63 0

PCT 22 P2 AV3

-. 05 TEC TEH

.610 ZBAZC 53 HI 37 36 1.14 0

PCT 18 P2 AV4

.00 TEC TEH

.610 ZBAZC 53 HI 41 36 1.53 0

PCT 21 P2 AV1

.00 TEC TEH

.610 ZBAZC 53 HI 43 37 1.28 0

PCT 18 P2 AVI

.25 TEC TEH

.610 ZBAZC 55 HI 43 37 3.08 0

PCT 31 P2 AV2

.08 TEC TEH

.610 ZBAZC 55 HI 43 37 2.70 0

PCT 29 P2 AV3

.28 TEC TEH

.610 ZBAZC 55 HI 37 38 1.10 0

POT 16 P2 AV1

.00 TEC TEH

.610 ZBAZC 57 HI 37 38 4.15 0

PCT 34 P2 AV2

-. 32 TEC TEH

.610 ZBAZC 57 HI 37 38 3.76 0

PCT 32 P2 AV3

.24 TEC TEH

.610 ZBAZC 57 HI 4

37 38

.87 0

PCT 14 P2 AV4

.00 TEC TEH

.610 ZBAZC 57 HI 32 39

.97 0

PCT 15 P2 AV2

-. 21 TEC TEH

.610 ZBAZC 55 HI 42 44 1.03 0

POT 15 P2 AVi

.12 TEC TEH

.610 ZBAZO 57 HI 42 44 1.12 0

POT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 41 45 5.37 0

PCT 41 P2 AV2

.00 TEC TEH

.610 ZBAZC 59 HI 41 45 3.04 0

PCT 32 P2 AV3

.00 TEC TEH

.610 ZBAZC 59 HI I41 45 5.12 0

PID 40 P2 AV2

.00 TEC TEH

.610 ZBAZC 97 HI 40 46 1.47 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI I40 46 1.83 0

POT 22 P2 AV3

.00 TEC TEH

.610 ZBAZO 57 HI 40 47

.98 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 59 HI 32 48 1.14 0

PCT 16 P2 AV2

.00 TEC TEH

.610 ZBAZC 57 HI 41 50 1.84 0

PCT 23 P2 AV3

.00 TEC TEH

.610 ZBAZC 61 HI 41 55 2.64 0

PCT 29 P2 AV2

.00 TEC TEH

.610 ZBAZC 63 HI 41 55 3.24 0

PCT 32 P2 AV3

.00 TEC TEH

.610 ZBAZC 63 HI 41 55 1.55 0

POT 20 P2 AV4

.19 TEC TEH

.610 ZBAZC 63 HI 38 59 2.79 0

POT 29 P2 AV2

.00 TEC TEH

.610 ZBAZC 61 HI 40 59 1.65 0

PCT 22 P2 AVi

.00 TEC TEH

.610 ZBAZC 61 HI 40 59 1.80 0

PCT 23 P2 AV2

.00 TEC TEH

.610 ZBAZC 61 HI 40 59 3.18 0

PCT 31 P2 AV3

.00 TEC TEH

.610 ZBAZC 61 HI 40 59 1.25 0

PCT 19 P2 AV4

.00 TEC TEH

.610 ZBAZC 61 HI 47 59 1.84 0

POT 23 P2 AVi

.35 TEC TEH

.610 ZBAZC 61 HI 401 66 1.26 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 61 HI 40 66

.96 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 61 HI

+-

+- --

-+"

+

-+1-

+

+

+

+t 4----+-.

.+

4 I

INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA+ PTYPE CAL L

+-

+----+-----4...

4"...

"-+--4+----+---+---

4--

""...+o

--+

+"-4-...

F 4

10 ST Max0PT 2

2 V

0 E

E

.1 BZ 1H 1

ST Max

SG -

B ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2RI4 CDE 20091001 10/22/2009 13:37:00

+------+........

+....---.----

+----..----.

+

+-

+........----+-

4'-

+-..

. 4-----

INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+---------------+

+-----+----+

+-----+-----+-----+-----+----+

+

+

+

+--------

43 67 1.91 0

PCT 22 P2 AVI

.05 TEC TEH

.610 ZBAZC 65 HI 43 67 5.71 0 PCT 39 P2 AV2

.13 TEC TEH

.610 ZBAZC 65 HI 43 67 5.39 0

PCT 38 P2 AV3

.00 TEC TEH

.610 ZBAZC 65 HI 43 67 1.57 0

PCT 20 P2 AV4

-. 22 TEC TEH

.610 ZBAZC 65 HI I32 70

.74 0

PCT 12 P2 AV

.23 TEC TEH

.610 ZBAZC 65 HI 32 70 2.18 0

PCT 24 P2 AV2

.00 TEC TEH

.610 ZBAZC 65 HI 32 70 5.47 0

PCT 39 P2 AV3

.00 TEC TEH

.610 ZBAZC 65 HI 36 73

.93 0

PCT 15 P2 AV2

.08 TEC TEH

.610 ZBAZC 69 HI 40 74 1.38 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 71 HI 40 74 1.73 0

PCT 22 P2 AV3

.00 TEC TEH

.610 ZBAZC 71 HI 25 75 1.86 0

PCT 23 P2 AV3

.00 TEC TEH

.610 ZBAZC 71 HI 40 76 1.02 0

PCT 16 P2 AV3

-.03 TEC TEH

.610 ZBAZC 71 HI 24 78 1.03 0

PCT 16 P2 AV4

-.02 TEC TEH

.610 ZBAZC 69 HI 36 81

.95 0

PCT 15 P2 AV2

.00 TEC TEH

.610 ZBAZC 71 HI 44 81 1.21 0

PCT 18 P2 AV3

-. 10 TEC TEH

.610 ZBAZC 71 HI 40 82 1.06 0

PCT 16 P2 AV2

.10 TEC TEH

.610 ZBAZC 69 HI 40 82 3.95 0

PCT 33 P2 AV3

.00 TEC TEH

.610 ZBAZC 69 HI I39 85 1.33 0

PCT 18 P2 AV2

.00 TEC TEH

.610 SBACC 79 HI I39 85 1.80 0

PCT 22 P2 AV3

.00 TEC TEH

.610 SBACC 79 HI 40 90 1.41 0

PCT 20 P2 AV2

.17 TEC TEH

.610 SBACC 81 HI 40 90 2.06 0

PCT 24 P2 AV3

.00 TEC TEH

.610 SBACC 81 HI 40 92 1.01 0

PCT 16 P2 AV2

.10 TEC TEH

.610 SBACC 81 HI I40 92 2.41 0

PCT 27 P2 AV3

.00 TEC TEH

.610 SBACC 81 HI 40 92

.94 0

PCT 15 P2 AV4

.31 TEC TEH

.610 SBACC 81 HI 340 93

.97 0

PCT 16 P2 AV2

.16 TEC TEH

.610 SBACC 83 HI I40 93 2.01 0

PCT 25 P2 AV3

-.10 TEC TEH

.610 SBACC 83 HI 38 95 2.23 0

PCT 28 P2 AV2

.00 TEC TEH

.610 SBACC 83 HI 36 96 1.89 0

PCT 23 P2 AV2

-.24 TEC TEH

.610 SBACC 81 HI 36 96 1.03 0

PCT 16 P2 AV3

-. 08 TEC TEH

.610 SBACC 81 HI I36 96 1.13 0

POT 17 P2 AV4

-. 03 TEC TEH

.610 SBAOC 81 HI I

39 96 1.53 0

PCT 21 P2 AVi

.00 TEC TEH

.610 SBACC 81 HI 39 96 2.92 0

PCT 29 P2 AV3

.07 TEC TEH

.610 SBACC 81 HI 39 96

.80 0

PCT 14 P2 AV4

.00 TEC TEH

.610 SBACC 81 HI I36 97 1.07 0

POT 18 P2 AV3

.00 TEC TEH

.610 SBAOC 83 HI I39 97 1.53 0

POT 22 P2 AVi

.00 TEC TEH

.610 SBACC 83 HI 39 97

.72 0

PCT 13 P2 AV2

.00 TEC TEH

.610 SBACC 83 HI 39 97 2.50 0

PCT 28 P2 AV3

.03 TEC TEH

.610 SBACC 83 HI I39 97

.84 0

POT 15 P2 AV4

.00 TEC TEH

.610 SBAOC 83 HI 37 98 1.06 0

POT 17 P2 AV4

.00 TEC TEH

.610 SBAOC 81 HI 38 98 1.74 0

PCT 22 P2 AV3

.00 TEC TEH

.610 SBACC 81 HI 38 98 1.43 0

PCT 20 P2 AV4

.00 TEC TEH

.610 SBACC 81 HI 36 99 1.28 0

PCT 20 P2 AV1

.00 TEC TEH

.610 SBACC 83 HI 36 99 1.48 0

PCT 22 P2 AV2

.00 TEC TEH

.610 SBACC 83 HI 37 99 1.60 0

PCT 22 P2 AV3

.00 TEC TEH

.610 SBACC 83 HI 29 100 1.85 0

PCT 23 P2 AV2

.00 TEC TEH

.610 SBACC 81 HI 29 100 1.10 0

PCT 17 P2 AV3

.00 TEC TEH

.610 SBACC 81 HI 36 100 1.29 0

PCT 19 P2 AV2

.00 TEC TEH

.610 SBACC 85 HI

+-

+-----

-- +--

-4"

-+

-+-....

-+-...

+-

+---+

-+--......+-

+----

+-+

+-

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOON INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-

  • -+---+

-+

4-...+

+--

+

+--......

+-....+

+-

+-+

3 97.2 0PT 1

P2A2 ST0 MaxEH

.1 SA 3H 2

ST Max

SG -

B ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 ODE 20091001 10/22/2009 13:37:00

+----------+---

+÷--÷

+

+---

+--..--+

+-..

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷----+----+----+

~+-----

÷------

+

+

30 101

.97 0

POT 16 P2 AV2

.08 TEC TEH

.610 SBACC 83 HI 30 101 1.17 0

POT 19 P2 AV3

.00 TEC TEH

.610 SBACC 83 HI I32 101 2.30 0

POT 28 P2 AV3

.00 TEC TEH

.610 SBAC 87 HI 32 101

.81 0

POT 15 P2 AV4

-. 08 TEC TEH

.610 SBACC 87 HI 33 103 1.08 0

PCT 17 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI 28 104 1.95 0

POT 24 P2 AV2

.00 TEC TEH

.610 SBACC 85 HI 29 104 1.24 0

POT 19 P2 AV3

.00 TEC TEH

.610 SBACC 85 HI 27 106 1.05 0

POT 17 P2 AV3

.00 TEC TEH

.610 SBACC 85 HI I25 108 2.06 0

POT 25 P2 AVi

-.09 TEC TEH

.610 ZBAZO 89 HI 259 108

.82 0

PCT 13 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 25 108

.70 0

PCT 11 P2 AV3

.10 TEC TEH

.610 ZBAZC 89 HII I25 108 1.66 0 POT 21 P2 AV4

-.06 TEC TEH

.610 ZBAZO 89 HI 22 109 1.03 0

PCT 16 P2 AV4

.32 TEC TEH

.610 ZBAZC 89 HI I2 110

.92 0 POT 14 P2 AV4

.10 TEC TEH

.610 ZBAZC 89 HI 21 110

.92 0

PCT 14 P2 AV4

.03 TEC TEH

.610 ZBAZC 89 HI

+

+----+...---+-----..+...-

÷----+

--+

+---.

+..-...--÷ I

INSPDATE ROW COL VOLTS DEG IND PER CHN LOON INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Ll

+----

+----+

÷.----.-----------+

÷-----+-÷

+

+.--.....--÷ Tubes: 59 Records: 109 3

ST Max

SG - C ANTI-VIBRATION BAR WEAR INDICATIONS Largest Percent Indication Per Tube Braidwood A2R14 CDE D5 a 65 PLUGGED TUBE I 6 1 0% io 19%;

2 45 20% to 29%

3 21 30% to 39%

110 105 100 95 90 85 80 75 0000 0000 0 -°..................

70 (P0000 65 60 55 50 45 40 35 30 I0000 0O 0OPO0OOO?000000100001 OOOýj 1...........

. 7..

0 0 :.3............

-13 a

_ 3 17 I a

25 20 15 10 5

°°°!

00 00a 45 40 35 30 25 20 15 00 03 o o1

.]

. 2 -

1

" I * :"

001.

2E;

1 I.

.0 I

-00 3............

22321.

1 1

a 3

3

-1

.0

. 00 00*.. 01

"........O

"".O' 02 0i 2.

.2

............ 2 -...

0 0

10 0

O0 O

2..

. O.

.0 3

3

.0...,....... 1 0

0 2

OO 1 3 31(

I 2

-0 I: :.

.. 0 0

.I O

0.........

0 0

T.........

O..00 0.....

0

. I O

  • ....j..............0 0....

.... i::....

...T..

0 0 o

o 0

00 00)00) 00114 00 0... 1.

0 o0T0..

00

+ :::::::0::00::: ::...

r 00 0:00 0

TO.....

I.

I..

.. I....

I...

I::::T I......

T o.........

~ ~

- ~- -~---~--------~-----*--* 11 a

I S.......

o°~~~~~~~~.

.l

+

-[.

+I

.... I I.

I0 0.7 i.

00...

=O 0.

T.

0 )00 0....

i ;.

....... +.... '.....o* 0 00(....

T.....T...

ooo 0......

...~

0~~~~~~~~~~~~~~

0.
  • l::
  • 1 i

T f..::j:°+

T1.....

o..

O O..

i....

'°"

°o

()

0.

00 o

'I

°

o.

i T

° °° o

0+

........... oo!......

... o o.T

...... oo..... Toio.....

0 0........

t.........

.I I.....

O0..

J I'

T..

.T.

.T.

00 45 35 30 25 15 5

5 0°.

0...

0000.

>000°0 oooo0

°°.

°,

o

°

.$:°

°

°

°

°

,°°

°°°°

I::::I
I::::I 0.000P.00009000qb0000(
  • OOOOcpOOO(oooooqopoo~oq(000090000/oooo~poooo (0 000 1/0 00 0 90 000 00 0000 009 000 000000 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electric Company LLC - ST Max 10(22/2009 20:25:50

SG -

C ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2RI4 CDE 20091001 10/22/2009 13:36:59

+---

-+--

+-.

+-+......

INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL Ll

+-

-+-------...

+----+----+----+---- ----.-------.----.

+-+--.

÷...÷....

.+

÷ 27 9

1.04 0

PCT 15 P2 AVU

-. 15 TEC TEH

.610 SBACC 51 Hj 27 9

.99 0

PCT 15 P2 AV4

.09 TEC TEH

.610 SBACC 51 HI 33 14 1.60 0

POT 22 P2 AV2

.05 TEC TEH

.610 ZBAZO 49 HI 33 14 1.32 0

PCT 20 P2 AV3

-. 03 TEC TEH

.610 ZBAZC 49 HI 33 14 2.23 0

PCT 27 P2 AV4

-. 03 TEC TEH

.610 ZBAZC 49 HI 32 16

.73 0

PCT 13 P2 AV2

.13 TEC TEH

.610 ZBAZC 49 HI 34 16

.74 0

PCT 14 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI 34 17

.75 0

PCT 14 P2 AV1

-. 32 TEC TEH

.610 SBACC 55 HI 34 17 1.53 0

PCT 22 P2 AV3

-. 03 TEC TEH

.610 SBACC 55 HI I36 17 3.01 0

POT 32 P2 AV2

.08 TEC TEH

.610 SBACC 55 HI 36 17 1.84 0

PCT 25 P2 AV3

.03 TEC TEH

.610 SBACC 55 HI 36 19 2.87 0

POT 31 P2. AV2

-. 27 TEC TEH

.610 SBAC 55 HI 36 19 3.84 0

PCT 36 P2 AV3

.05 TEC TEH

.610 SBACC 55 HI 36 19 1.14 0

PCT 18 P2 AV4

.21 TEC TEH

.610 SBACC 55 HI I36 20

.90 0

POT 16 P2 AV3

.03 TEC TEH

.610 ZBAZO 57 HI 36 20

.57 0

PCT 12 P2 AV4

.12 TEC TEH

.610 ZBAZC 57 HI 36 21

.92 0

PCT 16 P2 AV3

.05 TEC TEH

.610 SBACC 55 HI I38 21 1.70 0

POT 23 P2 AV2

.42 TEC TEH

.610 SBACO 55 HI 38 21 1.26 0

PCT 20 P2 AV3

.00 TEC TEH

.610 SBACC 55 HI 41 22

.98 0

PCT 17 P2 AV2

.08 TEC TEH

.610 ZBAZC 57 HI 41 22 2.25 0

PCT 28 P2 AV3

.03 TEC TEH

.610 ZBAZC 57 HI 41 22 1.25 0

PCT 20 P2 AV4

.05 TEC TEH

.610 ZBAZC 57 HI I42 22 2.68 0

POT 30 P2 AV3

.18 TEC TEH

.610 ZBAZC 57 HI 42 22 1.52 0

PCT 22 P2 AV4

.26 TEC TEH

.610 ZBAZC 57 HI 42 23 1.35 0

PCT 18 P2 AV3

.36 TEC TEH

.610 SBACC 47 HI 44 23

.83 0

PCT 13 P2 AVi

.20 TEC TEH

.610 SBACC 47 HI 44 23 3.27 0

PCT 32 P2 AV2

.10 TEC TEH

.610 SBAOC 47 HI I

44 23 3.99 0

POT 36 P2 AV3

.10 TEC TEH

.610 SBAOC 47 HI 44 23

.64 0

PCT 9

P2 AV4

.00 TEC TEH

.610 SBACC 47 HI I41 24

.89 0

POT 15 P2 AV3

-.26 TEC TEH

.610 ZBAZC 49 HI 42 25 3.08 0

PCT 31 P2 AV2

.00 TEC TEH

.610 SBAOC 47 HI 42 25 3.19 0

PCT 32 P2 AV3

.05 TEC TEH

.610 SBAOC 47 HI 42 25 1.21 0

PCT 17 P2 AV4

.15 TEC TEH

.610 SBACC 47 HI 36 26

.79 0

PCT 14 P2 AV2

.31 TEC TEH

.610 ZBAZC 49 HI I36 26 1.15 0

POT 18 P2 AV3

-. 31 TEC TEH

.610 ZBAZC 49 HI 45 26 1.44 0

PCT 21 P2 AV2

-. 13 TEC TEH

.610 SBACC 63 HI I45 26 2.11 0

PCT 26 P2 AV3

.05 TEC TEH

.610 SBACC 63 HI I45 26 1.00 0

POT 16 P2 AV4

.00 TEC TEH

,610 SBACC 63 HI 38 27 2.28 0

PCT 26 P2 AV2

.00 TEC TEH

.610 SBACC 47 HI 38 27 1.81 0

POT 22 P2 AV3

.21 TEC TEH

,610 SBACO 47 HI 44 28

.97 0

PCT 16 P2 AV2

-. 03 TEC TEH

.610 ZBAZC 49 HI 44 28 1.41 0

PCT 21 P2 AV3

.16 TEC TEH

.610 ZBAZC 49 HI 48 29

.47 0

PCT 9

P2 AV4

.00 TEC TEH

.610 SBACC 63 HI 38 30 1.72 0

PCT 22 P2 AV2

.41 TEC TEH

.610 SBACC 61 HI I38 30 1.93 0

POT 24 P2 AV3

.00 TEC TEH

.610 SBACC 61 HI 41 30 1.36 0

PCT 20 P2 AV2

.00 TEC TEH

.610 SBACC 63 HI 41 30 1.38 0

PCT 20 P2 AV3

.05 TEC TEH

.610 SBACC 63 HI 45 30 1.78 0

PCT 23 P2 AV2

.13 TEC TEH

.610 SBACC 63 HI 45 30 3.77 0

PCT 35 P2 AV3

.00 TEC TEH

.610 SBACC 63 HI

+

+....

+

-....+-....+---

+--

÷+ --

+-

+--÷

-+

+

.÷ I INSPDATE ROW COL VOLTS DEG IND PER CHN LOON INCHi INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-

+--

+-

+

-+÷-+-+-

÷

-+--

-+---...+---...

+--+

+---+

1 ST Wax

SG -

C ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:36:59

+----

+---------+

+----+--------+----+

+--

+-

+--

÷-

÷ I

INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+----+----+

+----+----+----+----+----+

+..÷..÷..------+-..

+-

+-÷--+-÷ 45 30 1.47 0

PCT 21 P2 AV4

.00 TEC TEH

.610 SBACC 63 HI 41 31 1.66 0

PCT 23 P2 AV1

-. 06 TEC TEH

.610 SBACC 65 HI 41 31 2.54 0

PCT 29 P2 AV2

.15 TEC TEH

.610 SBACC 65 HI 41 31 1.78 0

PCT 24 P2 AV3

.15 TEC TEH

.610 SBACC 65 HI 41 31

.85 0

PCT 15 P2 AV4

.32 TEC TEH

.610 SBACC 65 HI I43 33

.96 0

PCT 16 P2 AV2

.05 TEC TEH

.610 SBACC 65 H

36 34 2.06 0

PCT 25 P2 AV3

.03 TEC TEH

.610 SBACC 61 HI I38 34

.94 0

PCT 14 P2 AV2

.05 TEC TEH

.610 SBACC 61 H

41 34 2.48 0

PCT 25 P2 AV2

.00 TEC TEH

.610 SBACC 63 HI 41 34 2.50 0

PCT 29 P2 AV3

.03 TEC TEH

.610 SBACC 63 HI 46 34 2.09 0

PCT 26 P2 AV2

-. 08 TEC TEH

.610 SBACC 63 HI 46 34 2.04 0

PCT 25 P2 AV3

.00 TEC TEH

.610 SBACC 63 HI 46 34 1.40 0

PCT 20 P2 AV4

-. 22 TEC TEH

.610 SBACC 63 HI I41 35

.91 0

PCT 15 P2 AVi

-.19 TEC TEH

.610 ZBAZC 59 HI 41 36 1.77 0

PCT 23 P2 AV2

.05 TEC TEH

.610 SBACC 63 HI 41 36 1.86 0

PCT 24 P2 AV3

-. 03 TEC TEH

.610 SBACC 63 HI 41 36

.76 0

PCT 13 P2 AV4

.00 TEC TEH

.610 SBACC 63 HI I42 36

.75 0

PCT 13 P2 AV2

.00 TEC TEH

.610 SBACC 63 HI 42 36 2.81 0

PCT 30 P2 AV3

.03 TEC TEH

.610 SBACC 63 HI 42 36 1.22 0

PCT 18 P2 AV4

.09 TEC TEH

.610 SBACC 63 HI 41 38 3.08 0

PCT 32 P2 AV2

.00 TEC TEH 610 SBACC 63 I

41 38 1.71 0

PCT 23 P2 AV3

.00 TEC TEH

.610 SBACC 63 HI 38 39

.73 0

PCT 13 P2 AV2

-. 37 TEC TEH

.610 SBACC 65 HI 38 39

.95 0

PCT 16 P2 AV3

.24 TEC TEH

.610 SBACC 65 HI 42 39 1.14 0

PCT 18 P2 AV2

.23 TEC TEH 610 SBACC 65 I

42 39 1.77 0

PCT 24 P2 AV3

.03 TEC TEH

.610 SBACC 65 HI 241 41

.88 0

PCT 14 P2 AV3

.00 TEC TEH

.610 SBACC 69 HI 41 41

.80 0

PCT 13 P2 AV4

.00 TEC TEH

.610 SBACC 69 HI I43 41 1.13 0

PCT 17 P2 AVi

.54 TEC TEH

.610 SBACC 69 HI I43 41 4.14 0

PCT 37 P2 AV2

.55 TEC TEH

.610 SBACC 69 HI I43 41 2.33 0

PCT 28 P2 AV3

.15 TEC TEH

.610 SBACC 69 HII 42 42 1.02 0

PCT 20 P2 AV3

.00 TEC TEH

.610 SBACC 63 HI 2 38 42 1.7 0

PCT 21 P2 AV3

.00 TEC TEH

.610 SBACC 67 HI I

38 44

.89 0

PCT 15 P2 AV1

.28 TEC TEH

.610 SBACC 67 HI I

41 439 1.6 0

PCT 19 P2 AV2

.08 TEC TEH

.610 SBACC 67 HI I41 50 1.86 0

PCT 16 P2 AV1

.22 TEC TEH

.610 SBACC 671H 41 59 1.09 0

PCT 18 P2 AV2

.00 TEC TEH

.610 SBACC 71 HI 41 50 2.63 0

PCT 30 P2 AV1 5

TEC TEH

.610 SBACC 71 HI 41 50 1.36 0

PCT 14 P2 AVi

.00 TEC TEH

.610 SBACC 71 HI 41 50

.81 0

PCT 13 P2 AV3

.05 TEC TEH

.610 SBACC 71 HI 44 52 1.03 0

PCT 18 P2 AV2

.02 TEC TEH

.610 SBACC 71 HI 44 52

.99 0

PCT 17 P2 AV3

.00 TEC TEH

.610 SBACC 71 HI 45 52 1.07 0

PCT 18 P2 AVi

-. 11 TEC TEH

.610 SBACC 71 HI 45 52 2.05 0

PCT 26 P2 AV3

.01 TEC TEH

.610 SBACC 71 HI 46 52 1.74 0

PCT 24 P2 AV3

.00 TEC TEH

.610 SBACC 71 HI

-+÷-+--+

4

-+÷

-+--+-----

+-÷

+...+

o+

-+.--....

÷-

÷-

+-

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI 2

ST Max

SG - C ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 COE 20091001 10/22/2009 13:36:59

+.

+--------

+..+

"----+----+----..---.

+--

+--

-- +--PD-+A

-+

'+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

-4.-----.

+----+--

+

+--

-+....

+---------

46 52 3.42 0

PCT 34 P2 AV4 45 53

.91 0

PCT 11 P2 AVI 45 53

.93 0

PCT 12 P2 AV3 35 43 43 44 43 45 45 45 54 54 54 54 55 55 55 55 55 56 56 56 56 56 56 56 56 60 60 60 60 60 60 60 61 61 61 62 66 66 66 68 71 71 71 72 72 72 73 77 77 1.43 0

PCT 1.22 0

PCT 1.80 0

PCT

.93 0

PCT

.87 0

PCT 1.91 0

PCT 2.48 0

PCT 1.45 0

PCT

.69 0

PCT 1.73 0

PCT 1.32 0

PCT 1.37 0

PCT 1.90 0

PCT

.77 0

PCT 3.82 0

PCT 1.63 0

PCT 1.00 0

PCT 2.39 0

PCT 2.15 0

PCT 1.52 0

PCT 2.08 0

PCT 2.02 0

PCT 1.80 0

PCT

.96 0

PCT 1.54 0

PCT 1.58 0

PCT 1.37 0

PCT

.65 0

PCT 2.99 0

PCT 1.02 0

PCT 1.15 0

PCT 1.40 0

PCT 1.15 0

PCT 1.39 0

PCT 1.24 0

PCT 21 20 25 16 11 21 25 17 9

19 15 16 21 15 36 23 17 29 27 22 27 26 25 17 17 18 16 11

.32 17 18 21 17 20 18 12 23 22 25 19 27 P2 AVI P2 AV2 P2 AV3 P2 AV3 P2 AV2 P2 AVi P2 AV2 P2 AV3 P2 AV3 P2 AVI P2 AV2 P2 AV2 P2 AV3 P2 AVI P2 AVI P2 AV4 P2 AVI P2 AVI P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV2 P2 AV3 P2 AV2 P2 AV2 P2 AV3 P2 AV3 P2 AV3 P2 AV2 P2 AV3

.55

-.03

.00

-.08

.00

-. 08

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.00

.16

.00

.00

.00

.00

.00

-. 13

.00

.00

.03

.08

.00

.00

.21

.18

.11

-.57

-. 16

-.10

-. 05

-.08

-. 03

-. 11

-.05

.08

-. 21 TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC TEC TEH

.610 SBACC 71 H

73 H

73 H

71 H

71 H

71 H

71 H

73 H

73 H

73 H

73 H

73 H

73 H

73 H

73 H

73 H

71 H

71 H

71 H

71 H

71 H

71 H

71 H

71 H

71 H

71 H

71 H

73 H

73 H

73 H

77 H

75 H

75 H

75 H

75 H

77 H

77 H

77 H

81 H

81 H

75 H

77 H

79 H

79 H

.59 1.62 1.57 2.06 1.23 2.13 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT

---+----+----+----------

I INSPOATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT POIA PTYPE CAL LI

+.-

+.---

3 ST Max

SG -

C ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:36:59

+-"4-------.---

+-4--

+.----+----.--------

+-+-

+- -

+......

4---+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-"

+---

+----+---------------

+-

+.----+..--

4--+

+-

+-- ---

40 77 1.65 0

PCT 23 P2 AV2

-. 10 TEC TEH

.610 SBACC 79 HI 40 77 1.68 0

PCT 23 P2 AV3

-. 28 TEC TEH

.610 SBACC 79 HI 36 78 1.20 0 PCT 19 P2 AV2

.00 TEC TEH

.610 SBACC 81 HI 43 78

.74 0

PCT 12 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 43 78 1.33 0

PCT 18 P2 AV3

.05 TEC TEH

.610 ZBAZC 89 HI 42 79

.88 0

PCT 15 P2 AV3

-. 23 TEC TEH

.610 SBACC 87 HI 42 79

.77 0

PCT 14 P2 AV4

.00 TEC TEH

.610 SBACC 87 HI 42 80 1.15 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 42 80 1.99 0

PCT 24 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 42 80

.78 0

PCT 13 P2 AV4

.00 TEC TEH

.610 ZBAZC 89 HI 43 80

.97 0

PCT 15 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 40 81 1.35 0

PCT 20 P2 AVi

.00 TEC TEH

.610 SBACC 87 HI 40 81 3.54 0

PCT 34 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI 40 81 1.49 0

POT 21 P2 AV3

-. 20 TEC TEH

.610 SBACC 87 HI 42 81

.96 0

PCT 15 P2 AVI

.00 TEC TEH

.610 SBACC 87 HI 42 81 3.63 0

PCT 35 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI 42 81 2.72 0

PCT 30 P2 AV3

.20 TEC TEH

.610 SBACC 87 HI 42 81 1.28 0

PCT 19 P2 AV4

.00 TEC TEH

.610 SBACC 87 HI 41 82 1.17 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 42 82 2.17 0

PCT 25 P2 AV2

-. 10 TEC TEH

.610 ZBAZC 89 HI I42 82 1.37 0

POT 19 P2 AV3

-.10 TEC TEH

.610 ZBAZC 89 HI 40 83

.98 0

PCT 16 P2 AVi

.00 TEC TEH

.610 SBACC 87 HI I40 83 3.64 0

POT 35 P2 AV2

.00 TEO TEH

.610 S8AOO 87 HI 40 83 4.24 0

POT 37 P2 AV3

.00 TEC TEH

.610 SBACC 87 HI 41 83

.86 0

PCT 15 P2 AVi

.00 TEC TEH

.610 SBACO 87 HI 41 83 1.09 0

PCT 17 P2 AV2

-. 06 TEC TEH

.610 SBACC 87 HI 41 83 1.08 0

PCT 17 P2 AV3

-. 13 TEC TEH

.610 SBACC 87 HI 42 83

.70 0

POT 13 P2 AV2

,00 TEC TEH

.610 SBAOC 87 HI 42 83 1.60 0

PCT 22 P2 AV3

.00 TEC TEH

.610 SBACC 87 HI 38 84

.65 0

PCT 12 P2 AV3

-.08 TEC TEH

.610 ZBAZC 85 HI I43 84 1.38 0

POT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI I43 84 2.13 0

POT 25 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 33 85

.99 0

PCT 17 P2 AV3

-. 05 TEC TEH

.610 SBACC 83 HI 40 85 2.44 0

PCT 28 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI I40 85 1.43 0

POT 21 P2 AV3

-.20 TEC TEH

.610 SBACC 87 HI 45 85

.85 0

PCT 15 P2 AV2

-. 08 TEC TEH

.610 SBACC 87 HI 45 85 1.87 0

PCT 24 P2 AV3

.20 TEC TEH

.610 SBACC 87 HI 36 86 1.38 0

PCT 21 P2 AV2

.00 TEC TEH

.610 ZBAZC 85 HI 36 86 2.35 0

PCT 28 P2 AV3

.00 TEC TEH

.610 ZBAZC 85 HI 36 86 1.64 0

PCT 23 P2 AV4

.00 TEC TEH

.610 ZBAZC 85 HI I37 87

.61 0

POT 11 P2 AVi

.00 TEC TEH

.610 SBACC 83 HI I37 87 1.26 0

POT 19 P2 AV2

-.08 TEC TEH

.610 SBAOC 83 HI I37 87 1.51 0

POT 21 P2 AV3

.00 TEC TEH

.610 SBACC 83 HI 37 87

.68 0

POT 12 P2 AV4'

.00 TEC TEH

.610 SBACC 83 HI 40 88 1.22 0

PCT 18 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 40 88 2.44 0

PCT 27 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 41 88

.89 0

PCT 14 P2 AVI

.00 TEC TEH

.610 ZBAZC 89 HI 41 88 1.35 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 41 88 1.03 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 32 89 1.10 0

PCT 17 P2 AV2

.00 TEC TEH

.610 SBACC 83 HI

+----.....---

-+"-

4-+----+--F----+...4-...

+

+-

-+"-"-

+--

-+-

+-+...

I INSPDATE ROW COL VOLTS DEG INO PER CHN LOON INCH1 INCH2 BEGT ENDT PDIA PTYPE OAL LI

+-

+--

+--

+

+-t--I-...+-....+-....+---+----+-

+

+-""--+-

+4-

+-+

36 8.4 0PT 2

2A4 ST0 MaxEH

.1 ZA 5H 4

ST Max

SG - C ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2RI4 CDE 20091001 10/22/2009 13:36:59

+--

+----

+----+----+----+----+----+---------

+-------

++

+÷-

+-+....

4-÷ I

INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+---------------+

+-----+----+

+-----+-----+-----+-----+----+

+

+

+

+--------

36 89 1.50 0

PCT 21 P2 AV3

.00 TEC TEH

.610 SBACC 83 HI 37 89

.85 0

PCT 14 P2 AV3

-. 18 TEC TEH

.610 SBACC 87 HI 46 89

.62 0

PCT 12 P2 AV4

.00 TEC TEH

.610 SBACC 87 HI 36 90 2.23 0

PCT 27 P2 AV2

.00 TEC TEH

.610 ZBAZC 85 HI 36 90 3.32 0

PCT 33 P2 AV3

.00 TEC TEH

.610 ZBAZC 85 HI 36 90

.98 0

PCT 16 P2 AV4

.00 TEC TEH

.610 ZBAZC 85 HI 42 90 1.37 0

PCT 19 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 42 90 2.64 0

PCT 29 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 42 90 3.71 0

PCT 34 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 42 90 1.21 0

PCT 17 P2 AV4

.00 TEC TEH

.610 ZBAZC 89 HI 38 91 1.15 0

PCT 18 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI 40 91 1.26 0

PCT 19 P2 AV3

-. 08 TEC TEH

.610 SBACC 87 HI 40 91

.89 0

PCT 15 P2 AV4

.00 TEC TEH

.610 SBACC 87 HI 43 91

.85 0

PCT 14 P2 AV4

.00 TEC TEH

.610 SBACC 87 HI I33 92

.95 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 85 H

40 92 1.93 0

PCT 24 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 40 92 3.71 0

PCT 34 P2 AV3

.08 TEC TEH

.610 ZBAZC 89 HI 40 92

.91 0

PCT 14 P2 AV4

.00 TEC TEH

.610 ZBAZC 89 HI 41 92 1.77 0

PCT 22 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 41 92 1.36 0

PCT 19 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 41 92 1.10 0

PCT 16 P2 AV4

.00 TEC TEH

.610 ZBAZC 89 HI 36 93 1.07 0

PCT 17 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI 36 93

.77 0

PCT 13 P2 AV3

.00 TEC TEH

.610 SBACC 87 HI I37 93

.67 0

PCT 12 P2 AV2

.28 TEC TEH

.610 SBACC 87 HI I37 93

.83 0

PCT 14 P2 AV3

-. 08 TEC TEH

.610 SBACC 87 HI 40 94

.93 0

PCT 15 P2 AV2

.13 TEC TEH

.610 ZBAZC 89 HI 40 94 1.49 0

PCT 20 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 41 94 1.17 0

PCT 17 P2 AV3

.03 TEC TEH

.610 ZBAZC 89 HI 42 94

.77 0

PCT 13 P2 AV4

.43 TEC TEH

.610 ZBAZC 89 HI I36 95

.93 0

PCT 15 P2 AV3

-.21 TEC TEH

.610 SBACC 87 HI 38 95 1.12 0

PCT 18 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI 38 95 1.46 0

PCT 21 P2 AV3

.00 TEC TEH

.610 SBACC 87 HI 40 95 2.78 0

PCT 30 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI 40 95 1.32 0

PCT 19 P2 AV3

-. 03 TEC TEH

.610 SBACC 87 HI I40 95

.87 0

PCT 15 P2 AV4

.09 TEC TEH

.610 SBACC 87 H

36 96

.88 0

PCT 14 P2 AV2

.00 TEC TEH

.610 ZBAZC 89 HI 36 96 1.00 0

PCT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI I40 97

.68 0

PCT 11 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 H

40 97 1.33 0

PCT 18 P2 AV4

.00 TEC TEH

.610 ZBAZC 89 HI 32 99 1.20 0

PCT 18 P2 AV3

.00 TEC TEH

.610 SBACC 87 HI I36 99

.71 0

PCT 13 P2 AVI

.00 TEC TEH

.610 SBACC 87 HI I36 99 1.29 0

PCT 19 P2 AV2

.03 TEC TEH

.610 SBACC 87 HI I36 99 3.16 0

PCT 32 P2 AV3

.00 TEC TEH

.610 SBACC 87 HI 36 99 1.16 0

PCT 18 P2 AV4

.08 TEC TEH

.610 SBACC 87 HI 34 100 1.10 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 89 HI 31 101 1.09 0

PCT 17 P2 AV3

.00 TEC TEH

.610 SBACC 87 HI 389--

-1.46P--CT--+--

21 P2

.00.

6÷-- --

I I

INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHi INCH2 BEGT ENDT PDIA PTYPE CAL LI 5

9ST Max

SG -

C ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:36:59

-+÷----

÷.----.

+--

-+

+....-+----

+-

÷

÷

+......

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+--.----

-+-....

+-+-

÷-

-÷-

-÷...........----.---- -......-

34 101

.78 0

PCT 14 P2 AV2

.00 TEC TEH

.610 SBACC 87 HI 34 101 1.99 0

PCT 25 P2 AV3

-. 16 TEC TEH

.610 SBACC 87 HI 31 102

.86 0

PCT 15 P2 AV2

.05 TEC TEH

.610 ZBAZC 85 HI 31 102 1.20 0

PCT 19 P2 AV3

.19 TEC TEH

.610 ZBAZC 85 HI 27 103

.70 0

PCT 12 P2 AV2

.08 TEC TEH

.610 SBACC 83 HI

+---------------+

+-----+----+

+-----+-----+-----+-----+----+---+

+-----+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+---------------+

+-----+----+

+-----+-----+-----+-----+----+---+

+-----+

+-------

Tubes: 127 Records: 241 6

ST Max

SG - D ANTI-VIBRATION BAR INDICATIONS Largest Percent Indication Per Tube Braidwood A2R14 CDE D5 a 26 PLUGGED TUBE

-54 29, 2 44 20% to 29%

3 1.0 30% to 39%,'

.10 105 100 95 90 85 80 75 70 65 60 0

1 1

1 oooo0000000@0000(000.

02o(o OpO...

aD 0

0 2

55I 000 50 45 40 0000Q00o00oq0000 35 30 25 20 15 10 T 0,)000l.

5 000°....

0 0.-,

i.

000

,.00 45 45 40 35 30 25 10 2 0

~..

00 00..

2 1 0

1_

=.

2..0 00...

32 :.2 -

00........

00 0................2..2

... a+......

1 2.....

002 oo.

2

.. 2.2.

.211

.... 00 002. -.0.......

t 2....

0 0

0 00 000 0

(

o 0 3321

-,ool......

2 2

0......

.0 0....

f.. 0 0

T 0.... 0.........

...... 0 0.....

.. 0 0...................

Do 1

S.....

o0

.....°.......

2.

0 o

o.......o 1

q...,.

0 00 00--

00.

0.".

.1 00 0

-2

0.......

0000.01 0

0

, o.......

I........

00000 000...

0 0 0..

0:

  • o 00....T )00Q 1

I 0000

00.....

o,............

T..........000.::~

.....I S.

(

0 000 00 000 00

....T.... T..........

o.......................................

S.

o....

0

.o.

t.o o

.00 0

.:.T T

.0 0

0..

+....

...........................1

+

+...

....+

- --T


i ----

0

° ° o

0.. o o......

o o o.........

...T....

..: I....

o o

0 0..

...o1¢

00.

I T o 7 "

0 0...

T

.i 0

0..

0 oo.*

I I: :

:T...

oo0 35 15 10 5

15 5

0000 000 i10 105 100 95 90 65 4

I I

'000

.0.0. :0.........00000

¢oooo0oooooooooooo, 85 80 75 70 O00(0oooo0o00oooopooo00000000oooo 60 55 50 45 40 35

)000 30 25 20 15 10 5

Wesfinghouse Electdc Company LLC - ST Max 1012212009 20:28:30

SG - D ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:37:00

.-------- +..---.

+-----..

+

+

-+-

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----.----+.

+----+----+-

--- --+

+---

+---

+-

26 8

1.72 0

PCT 23 P2 AV1

-. 06 TEC TEH

.610 SBACC 43 HI 26 8

1.15 0

PCT 18 P2 AV4

.00 TEC TEH

.610 SBACC 43 HI 23 9

.96 0

PCT 16 P2 AV4

.23 TEC TEH

.610 ZBAZC 45 HI I29 18 1.71 8 POT 23 P2 AV2

.0 TEC TEH

.618 SBACC 43 HI 29 10 2.13 0

PCT 26 P2 AV3

.00 TEC TEH

.610 SBACC 43 HI 29 11 1.39 0

PCT 28 P2 AV2

.00 TEC TEH

.610 ZBAZC 45 HI 29 11 1.66 0

PCT 23 P2 AV3

.00 TEC TEH

.610 ZBAZC 45 HI 93 11 2.88 0

PCT 32 P2 AV2

.00 TEC TEH

.610 ZBAZC 45 HI 30 11 1.801 0

PCT 18 P2 AV3

.00 TEC TEH

.610 ZBAZC 45 HI 30 11 1.12 0

PCT 18 P2 AV4

.00 TEC TEH

.610 ZBAZC 45 Hl I29 12 1.36 8

POT 28 P2 AV4

-.83 TEO TEH

.618 SBACO 43 HI I29 13

.88 8 POT 15 P2 AV2

-.27 TEC TEH

.618 ZBAZC 45 HI I38 13

.85 8 POT 15 P2 AV2

-.88 TEC TEH

.618 ZBAZO 45 HI 30 13 1.11 0

PCT 18 P2 AV3

-. 47 TEC TEH

.610 ZBAZC 45 HI 29 14 1.45 0

PCT 21 P2 AV2

-. 03 TEC TEH

.610 SBACC 43 HI I29 14 1.39 8

POT 28 P2 AV3

.88 TEC TEH

.618 SBAOO 43 HI I31 14

.65 8 POT 12 P2 AVi

-.85 TEC TEH

.618 SBACC 43 HI 33 14

.97 0

PCT 16 P2 AV2

-. 23 TEC TEH

.610 SBACC 43 HI 33 14

.85 0

PCT 15 P2 AV3

.03 TEC TEH

.610 SBAOC 43 HI I28 16

.83 8

POT 15 P2 AV3 2.33 TEC TEH

.618 SBACC 43 HI 36 17 1.13 0

PCT 18 P2 AV2

.47 TEC TEH

.610 ZBAZC 45 HI 28 18

.82 0

PCT 15 P2 AV3

-. 05 TEC TEH

.610 SBACC 43 HI I37 23

.89 8 POT 16 P2 AV2

.82 TEC TEH

.618 ZBAZO 49 HI 34 25 1.84 0

PCT 18 P2 AV2

.08 TEC TEH

.610 ZBAZC 49 HI I34 25 1.52 8

POT 23 P2 AV3

-.83 TEC TEH

.618 ZBAZC 49 HI 37 27

.88 0

PCT 16 P2 AVI

.05 TEC TEH

.610 ZBAZC 49 HI 37 27

.94 0

PCT 17 P2 AV3

-. 08 TEC TEH

.610 ZBAZC 49 HI 37 29

.68 0

PCT 14 P2 AV3

.03 TEC TEH

.610 ZBAZC 49 HI S41 29 1.54 0

PCT 23 P2 AV3

.33 TEC TEH

.610 ZBAZC 49 HI I29 31 1.73 8 POT 23 P2 AV3

-.13 TEC TEH

.618 ZBAZO 41 HI I29 31 2.23 8 POT 27 P2 AV4

-.19 TEC TEH

.618 ZBAZO 41 HI I41 33 1.92 8 POT 26 P2 AV2

.88 TEC TEH

.618 ZBAZC 49 HI I41 33

.75 8 POT 15 P2 AV3

.83 TEC TEH

.618 ZBAZO 49 HI 37 34 1.65 0

PCT 21 P2 AV2

.00 TEC TEH

.610 SBACC 47 HI 37 34 1.58 0

PCT 28 P2 AV3

-. 05 TEC TEH

.610 SBACC 47 HI I41 34 1.26 8 POT 17 P2 AV3

-.86 TEC TEH

.618 SBAOC 47 HI 42 35 2.88 0

PCT 26 P2 AV2

.02 TEC TEH

.610 ZBAZC 49 HI 42 35

.90 0

PCT 16 P2 AV3

-. 11 TEC TEH

.610 ZBAZC 49 HI 42 35

.88 0

PCT 15 P2 AV4

.03 TEC TEH

.610 ZBAZC 49 HI 43 35

.96 0

PCT 17 P2 AV4

-. 08 TEC TEH

.610 ZBAZC 49 HI 33 36 1.14 0

PCT 18 P2 AV3

-. 08 TEC TEH

.610 ZBAZC 41 HI 43 36 2.13 0

PCT 24 P2 AV1

.00 TEC TEH

.610 SBACC 47 HI 43 36 3.88 0

PCT 34 P2 AV3

.00 TEC TEH

.610 SBACC 47 HI 32 37 1.82 0

PCT 16 P2 AV3

-. 19 TEC TEH

.610 ZBAZC 39 HI I

INSPDATE ROW COL VOLTS DEG IND PER CHN LOON INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI 11 3T 1

0

-C 26 P2

÷.

. ÷...... Max 1

ST Max

SG -

D ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:37:00

+..----

+-----------+-----+----+---+----+----

+

÷--

+

-+.

+..+--+-

I INSPDATE ROW COL.

VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENOT PDIA PTYPE CAL LI

+..----

.+....----.----+.

+- --

+- -------

+---+----+---+

+-+--

39 37

.91 0

PCT 17 P2 AV3

-. 11 TEC TEH

.610 ZBAZC 49 HI I

48 37

.77 0

PCT 15 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI 39 38 1.1 0

POT 19 P2 AV3

.03 TEC TEH

.610 ZBAZC 47 HI 36 38 3.47 0

PCT 13 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI 36 39 1.46 0

PCT 24 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI 36 39 1.73 0

PCT 24 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 Hi 36 39 1.63 0

PCT 24 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 Hi 39 40 1.21 0

PCT 17 P2 AV3

.11 TEC TEH

.610 SBACC 47 HI S43 40 1.65 0

POT 21

-P2 AVi

.11 TEC TEH

.610 SBAO 47 HI 43 40 1.75 0

PCT 22 P2 AV2

.40 TEC TEH

.610 SBACC 47 HI 43 40 1.95 0

POT 23 P2 AV3

.00 TEC TEH

.610 SBACC 47 HI 43 40 1.42 0

PCT 19 P2 AV4

.10 TEC TEH

.610 SBACC 47 HI I

34 41

.97 0

POT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 HI 38 41 1.12 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 HI 38 41 1.05 0

PCT 18 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI 40 42 1.04 0

PCT 15 P2 AV2

.29 TEC TEH

.610 SBACC 47 HI I41 42 1.38 0

POT 18 P2 AV2

.00 TEC TEH

.610 SBACC 47 HI 41 42 1.16 0

POT 16 P2 AV3

-.05 TEC TEH

.610 SBACC 47 HI 37 43

.89 0

PCT 16 P2 AV2

.06 TEC TEH

.610 ZBAZC 49 HI 38 43 1.14 0

POT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 HI 38 43

.89 0

PCT 16 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI 39 43 1.12 0

PCT 19 P2 AVi

.03 TEC TEH

.610 ZBAZC 49 HI I39 43 1.07 0

POT 18 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI I44 43

.87 0

PCT 16 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 HI 38 44 2.21 0

POT 25 P2 AV2

.00 TEC TEH

.610 SBACC 47 HI 38 44 1.65 0

PCT 21 P2 AV3

.20 TEC TEH

.610 SBACC 47 HI

.39 44 1.01 0

POT 15 P2 AV3

-. 18 TEC TEH

.610 SBACC 47 H

45 44 1.42 0

PCT 19 P2 AV2

.00 TEC TEH

.610 SBACC 47 HI 45 44 1.68 0

PCT 21 P2 AV3

.23 TEC TEH

.610 SBACC 47 HI 45 44

.96 0

POT 14 P2 AV4

.00 TEC TEH

.610 SBACC 47 HI 39 45 1.15 0

PCT 19 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 HI 39 45 1.92 0

PCT 26 P2 AV3

.00 TEC TEH

.610 ZBAZC 49 HI I42 45 1.48 0

POT 22 P2 AV4 2.61 TEC TEH

.610 ZBAZC 49 HI 43 45

.92 0

PCT 17 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 HI 41 46 1.35 0

PCT 18 P2 AV2

.00 TEC TEH

.610 SBACC 47 HI 41 46 2.53 0

PCT 27 P2 AV3

.00 TEC TEH

.610 SBACC 47 HI I45 46 2.30 0

POT 26 P2 AV3

-. 03 TEC TEH

.610 SBACC 47 HI I45 46 1.31 0

POT 18 P2 AV4

.16 TEC TEH

.610 SBACC 47 HI 33 47 1.04 0

POT 17 P2 AV2

.35 TEC TEH

.610 ZBAZC 41 HI 39 47

.97 0

PCT 17 P2 AV1

.03 TEC TEH

.610 ZBAZC 49 HI 39 47 1.76 0

PCT 25 P2 AV2

.00 TEC TEH

.610 ZBAZC 49 HI I39 47 2.32 0

PCT 28 P2 AV3

.19 TEC TEH

.610 ZBAZC 49 HI 42 47 2.37 0

PCT 29 P2 AV3

.12 TEC TEH

.610 ZBAZC 49 HI 26 48 2.34 0

PCT 26 P2 AV2

.26 TEC TEH

.610 ZBAZC 39 HI 4

5 4..4÷ 4

4

.96..PC 14 P2 A

4-.

00..

TE-T.610 SB-C

47. HI..

÷ I INSPDATE ROW COL VOLTS DEG IND PER CHN LOON INCH1 INCH2 BEGT ENDT PDIA+ PTYPE CAL L

+-

+-+-----4-+-

+--+----+

4....

+--

- -+-+...

+-

39 4.2 0PT 2

2 ST3 MaxE TH

.10ZA 9H 2

ST Max

SG -

D ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 COE 20091001 10/22/2009 13:37:00

.----.---- +-------+

"--------+----+---+--------+-----

4---+-

++-

+-+...

+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL Li

+------+

+-+.

+...

4-+-

+- --+-

-+----

"-+

39 39 40 40 41 41 40 41 41 26 45 45 45 49 37 42 42 42 49 33 42 42 44 44 45 45 45 46 46 49 40 40 49 38 38 41 49 49 38 41 41 39 39 39 39 48

.85 0 PCT 48 1.34 48 1.76 48 2.96 48 3.78 48 1.36 49 1.57 49 3.47 49 1.04 50

.86 50 1.97 50 3.34 50 1.52 50

.84 51 1.60 51 1.03 51 1.62 51 1.25 51

.77 52 1.03 52 3.45 52 1.64 56 2.07 56 1.61 56 1.30 56 2.50 56 3.25 56 1.57 56 2.14 61 1.55 62 1.36 62

.83 63

.77 64 1.68 64 2.87 65 1.87 65 1.03 66

.99 67 1.78 67 1.15 67 1.28 68 1.45 68 1.02 70 1.22 70 1.43 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0 PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 0

PCT 14 19 23 31 34 20 23 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV2 34 18 14 24 32 21 15 23 18 24 20 15 16 33 22 25 22 19 28 32 21 26 23 21 15 13 24 31 24 16 16 23 17 18 22 18 20 22 P2 AV2 P2 AV3 P2 AV2 P2 AVi P2 AV2 P2 AV3 P2 AV1 P2 AV2 P2 AVI P2 AV2 P2 AV3 P2 AV4 P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AVI P2 AV2 P2 AV3 P2 AV4 P2 AV2 P2 AV3 P2 AV3 P2 AV1 P2 AVi P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV3 P2 AV2 P2 AV3

.16

.00

.26

.00

.00

-. 03

.00

.08

.00

.49

.00

.00

.21

.00

.00

.00

.00

.00

.08

.21

.00

.11

.00

.00

-. 08

.00

.11 00 00

.00 00 00

.00

.00

.05

.00

.00

.00

-.54

.42

.37

.26

-. 26

-.05

-. 13 TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH TEC TEH

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 SBACC

.610 SBACC

.610 SBACC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 SBACC

.610 ZBAZC

.610 ZBAZC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 SBACC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC

.610 ZBAZC 51 H

51 H

51 H

51 H

51 H

51 H

53 H

53 H

53 H

39 H

51 H

51 H

51 H

53 H

53 H

53 H

53 H

53 H

53 H

51 H

51 H

51 HI 51 H

51 H

51 H

51 H

51 H

51 H

51 H

53 H

53 H

53 H

51 H

53 H

53 H

51 H

51 H

51 H

55 H

55 H

55 H

57 H

57 H

57 H

57 H

+.......

+----+----..+

+-"----

-+..----+-----

+-

+...+...---.+-

-- +

+-.....+-..

.+.-

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL Ll

+---

+-----.----------

-+- -+-------+-------.

+- -"-

+----+---

-+---"

ST Max

SG - D ANTI-VIBRATION BAR WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 13:37:00

+----+----.--..+

+--.+---+.--...--

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-----+.---.----..

+.------.----+.

+--

-+....

...----.-.+-......

÷ 37 74 1.10 0

PCT 19 P2 AV1

.00 TEC TEH

.610 ZBAZC 57 HI 37 74 1.15 0

PCT 19 P2 AV2

.21 TEC TEH

.610 ZBAZC 57 HI 37 74

.99 0

PCT 18 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 35 75 1.28 0

PCT 19 P2 AVi

-. 11 TEC TEH

.610 SBACC 55 HI 35 75 2.18 0

PCT 26 P2 AV3

.11 TEC TEH

.610 SBACC 55 HI 39 76 1.15 0

PCT 19 P2 AV2

-. 03 TEC TEH

.610 ZBAZC 57 HI 41 76 1.29 0

PCT 20 P2 AV2

.18 TEC TEH

.610 ZBAZO 57 HI 41 76

.96 0

PCT 18 P2 AV3

.00 TEC TEH

.610 ZBAZC 57 HI 37 79 1.01 0

PCT 15 P2 AV2

.47 TEC TEH

.610 SBACC 63 HI I

34 82 1.33 0

PCT 19 P2 AV2

-. 24 TEC TEH

.610 SBACC 63 HI 34 82 1.04 0

PCT 16 P2 AV3

-. 29 TEC TEH

.610 SBACC 63 HI I

42 82

.86 0

PCT 15 P2 AV2

.00 TEC TEH

.610 SBACC 65 HI 42 82 1.07 0

PCT 18 P2 AV3

.00 TEC TEH

.610 SBACC 65 HII 43 82

.97 0

PCT 16 P2 AV2

.05 TEC TEH

.610 SBACC 65 HI I

35 83

.97 0

PCT 15 P2 AV2

.00 TEC TEH

.610 SBACC 63 HI I

35 84 1.29 0

PCT 20 P2 AV2

.00 TEC TEH

.610 SBACC 65 HI 35 84 1.48 0

PCT 22 P2 AV4

.00 TEC TEH

.610 SBACC 65 HI 41 84 1.61 0

PCT 22 P2 AV3

-. 11 TEC TEH

.610 SBACC 65 HI 43 84 1.94 0

PCT 25 P2 AV3

.00 TEC TEH

.610 SBACC 65 HI S44 92 1.96 0

POT 17 P2 AV4

.00 TEC TEH

.610 SBACC 69 HI 42 85 1.20 0

PCT 15 P2 AV3

.00 TEC TEH

.610 SBACC 67 HI 42 85 1.60 0

PCT 21 P2 AV2

.00 TEC TEH

.610 SBACC 67 HI 42 83 5

1.1 0

PCT 15 P2 AV3

.00 TEC TEH

.610 SBACC 67 HI 43 86 1.31 0

PCT 21 P2 AV2

.08 TEC TEH

.610 SBACC 69 HI 44 96 1.16 0

PCT 21 P2 AV3

.23 TEC TEH

.610 SBACC 69 HI 43 97 1.72 0

PCT 12 P2 AV2

.00 TEC TEH

.610 SBACC 69 HI S38 97 2.15 0

POT 25 P2 AVi

.00

  • TEC TEH

.610 SBACC 67 HI 38 93 1.74 0

PCT 21 P2 AV2

.00 TEC TEH

.610 SBACC 67 HI 38 97 1.98 0

PCT 12 P2 AV3

.00 TEC TEH

.610 SBACC 67 HI 390 97 1.32 0

POT 18 P2 AV2

.00 TEC TEH

.610 SBAC 67 HI 39 97 1.36 0

PCT 21 P2 AV3

.00 TEC TEH

.610 SBACC 67 HI 30 101 1.72 0

POT 17 P2 AV2

.00 TEC TEH

.610 SBAC 71 HI 39 93 1.15 0

PCT 16 P2 AV3

.00 TEC TEH

.610 SBACC 67 HI 32 96 1.01 0

PCT 21 P2 AV2

.00 TEC TEH

.610 SBACC 67 HI 39 96 1.18 0

PCT 20 P2 AV3

.13 TEC TEH

.610 SBACC 69 HI 35 97 1.72 0

PCT 24 P2 AV2

.11 TEC TEH

.610 SBACC 69 HI 38 97 2153 0

PCT 25 P2 AV3

.00 TEC TEH

.610 SBACC 67 HI 38 191 1.74 0

PCT 22 P2 AV2

.00 TEC TEH

.610 SBACC 671 Hl 40 197 1.36 0

PCT 18 P2 AV3

.00 TEC TEH

.610 SBACC 671 HI 4

ST Max

Attachment B.6 Tubes Containing Pre-heater Wear

SG - B PREHEATER WEAR INDICATION Braidwood A2R14 CDE D5 a 49 PLUGGED TUBE X

3 TUBE WITH WEAR INDICATION 10 105 188 95 90 85 80 75

.000.0000.0000

"'.T...

...00...

I....

00

    • o**e 70 65 60 55 50 45 40 35 30 25 20 15 10 000000000oooqoooxopoo0ooooo0oooopooo,, I 0

xT

.. i..

1300 T.....

0,000 0

.,?

o

    • ?

0 5

45 40 35 25 000 0.01................................

01

°°~~~....I

..I°

..... I.......T..

.... T.....

.0° o0......

0

............... o.....

o0 G o..

T I

S.........................................

00 0... =

=.===== = 0

=======. :::",

C)

,::::::0:::: :::::: : : : : : : : : :

o.0

....-0 0........

0

.o o....

.o

.......o0................. 0 00.0..

00 00 0

0.

00..

0

0.

...0.

T.

O..

. O I

I T:

o o*' "-

-000 0...

0....

0..

0 0........................

I 0

0 T....

0 I

(ED) e___)-

1 0-1(e ea@&

o.".

0".'::j t

t

.... t......

00 0

) 0 0

.... T....

0" 0.......

c T.

.0 00i

.i.

.i.

.i.

.i.

. i

0.

0...............................

i.....i.........i....

i

.....t....

i..

° 00..

0 T.

T.

T.

00 000.

T.........

0....

0.

T

.T 01.............-,

oooo oooo oooo

,..oo..o..,,

0 01.....

0 0...*

  • 00.......................................................

/0 0.

//

I o...

0...

0...

0

,..0.....0 0...

T 0

0........

000.........

0000 0

0 0

45 40 35 25 20 15 1A 15 5

5 00..

0...

0000 o0000 P10o0P0090000 118 105 100 I.........

I..........

0 60 68 55 50 45 48 35 38 25 28 15 18 5

ý00004 oo oo41o o0o 000000o00000 0000 95 90 85 80 75 70 65 Westinghouse Eldctic Company LLC - ST Max 10/22/2009 20:23:08

SG B

PREHEATER WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 12:12:48

+..----

+--+----

+-----+-------+........--------

+-----+-

+

+-+...

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+-----------+--------+

+----+----+---

+----+-----

+

-+--

47 39

.16 0

PCT 5

P5 03C

-. 16 TEC TEH

.610 ZBAZC 109 HI 2008/04/01 47 39

.15 89 VOL P4 03C

-. 37 03C 03C

.610 ZPSNN 10 CI 2008/04/01 47 39 NOD TEH TEH

.610 ZPSNM 53 HI 2008/04/01 47 39

.64 0

RWS P2 03C

-. 48 TEC TEH

.610 ZBAZC 97 HI 2008/04/01 47 39

.22 0

PCT 4

P5 03C

-. 48 TEC TEH

.610 SBACC 145 HI 47 41

.20 0

PCT 6

P5 03C

-. 03 TEC TEH

.610 ZBAZC 109 HI 2008/04/01 47 41

.10 120 VOL P4 03C

.29 03C 03C

.610 ZPSNN 10 CI 2008/04/01 47 41 NDF 2

TEH 1.23 TEH TEH

.610 ZPSNM 53 HI 2008/04/01 47 41

.47 0

RWS P2 03C

.30 TEC TEH

.610 ZBAZC 97 HI 2008/04/01 47 41

.22 0

PCT 4

P5 03C

.30 TEC TEH

.610 SBACC 145 HI 49 49

.20 0

PCT 6

P5 05C

-. 03 TEC TEH

.610 ZBAZC 109 HI 2008/04/01 49 49 NDD TEH TSH

.610 ZPSNN 7

HI 2008/04/01 49 49

.19 98 VOL P4 05C

-. 46 05C 05C

.610 ZPSNN 10 CI 2008/04/01 49 49 1.89 180 INR P1 AV2

.00 TEC TEH

.610 ZBAZC 105 HI 2008/04/01 49 49 2.83 179 DNT P1 AV3

.00 TEC TEH

.610 ZBAZC 105 HI 2008/04/01 49 49

.66 0

RWS P2 05C

-. 22 TEC TEH

.610 ZBAZC 105 HI 2008/04/01 49 49

.20 0

PCT 3

P5 05C

-. 30 TEC TEH

.610 SBACC 145 HI

+...----

++-

+

+----+

+--+-

-+

+-

+-......

+.

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+

+-

-+.----+--

-+----+.----+----+----+-------+

-+----+--+

+.....-.

+......

+-

Tubes: 3 Records: 17 1

ST Max

SG - C PREHEATER WEAR INDICATION Braidwood A2R14 CDE D5 a 65 PLUGGED TUBE X

1 TUBE WITH WEAR INDICATION 110 105 100 95 90 85 80 75 70 oo0oOoo00o0oo0000(oooo O(

65 60 55 50 45 40 0oaoo 0o0 00 o00OO~o ooooo0000 a

0 0* -131....

13 0...

°

[]

..a........

35 30 (P000 25 20 15 10 5

0(

000.

i 00. *+****'"**

t****

1o- -003 ooa31 00 a

a a...........

T..............

o 00o.

a 0...............

T..........

00 oa...

a.................

. 00 0,...

a o

0a.

T0.......

o0 0 0..............

. ~.

.0 0..

(.

+ o

s.

TIII..

................. 0 00::::

.~i

.ii oo...00 oo....0.....

...... a.........0 0

00.....

0 0........

. 1

.o.o I..

o *...

.:I:

o o.,...

..T00

  • 0.........0 o.......

0.......

0

0.......

0 0 0

0..........00 0............0 0.......

... 0 0.........

......... 00*

00-...........

0 Oa.....

0 0........

000 l.l l.0 o....

0 0.............

0.............aa S.......

0 0"

O00.........!iiliiiii..

........................................-o C

0............

o o.

.. I...

1....

0.... T....

T.0.

00 0.... I...

0.... 0 o

00....

o T

0 0

0:

oi +=

o.

0 0 0 0 00 0 0 0 0

0 0

00o.0000.ooa17....

,o o

0...

I--

O T.

I -

...10 0°..

.. i i i i i i i...

1 3

.....t To...

0 :

t.... I.

...I..I...

.... 13

[

0 0

.0 o.......

..+

0 0

0 0

0 I

... +....+.....

0.

o....

0......1 -

+

.T.

.+.

.T.

[

T...

.T.

.t.

.o

+ + T...... + ;

0..

.. OT.. 1.

.0T IT T,

(). :

I

):~

0 000~~

0 o..

7..

I..........

..... 00

-0

I o o.

. o o....

o o~

0 (0....

45 40 35 2b 20 15 5

0o.

0o..

0...

0000

,O000(pOo 0 00(0

I::::

)0000ý00000 000O000 o000) 0000

,0000(poooo(poooo(ý0000(poooo(POO00(poooo(POO00(poooo(pooooToooopoooo 110 1O5 100 95 90 85 80 75 70 65 60 Westinghouse Electnc Company LLC - ST Max 10122/2009 20:26:20 55 50 45 40 35 30 25 20 15 10 5

SG -

C PREHEATER WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 12:12:46

+--

+- -

-+-

+

4.....

+....

4"

+

+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

++---

+-

+

+---

+----

-"....+......---

I 49 65

.22 0

PCT 36 P6 07C

-. 36 TEC TEH

.610 ZBAZC 113 HI I 2008/04/01 49 65

.94 85 VOL P4 07C

-. 45 07C 07C

.610 ZPSNN 10 CI I 2008/04/01 49 65 NOD TEH TEH

.610 ZPSNN 75 HI I 2008/04/01 49 65 3.17 178 DNT P1 AV4

.00 TEC TEH

.610 SBACC 127 HI I 2008/04/01 49 65 4.53 0

RWS P2 07C

-. 49 TEC TEH

.610 SBACC 127 HI I 2008/04/01 49 65 3.03 0

PCT 30 P6 07C

.00 TEC TEH

.610 SBACC 159 HI

+

+----+-----+

+--------+----+

+-

+-..

+-

4----

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCH1 INCH2 BEGT ENDT PDIA PTYPE CAL LI

+-

+......

+...

+- ---

+----------.

Tubes: 1 Records: 6 1

ST Max

SG - D PREHEATER WEAR INDICATION Braidwood A2R14 CDE D5 a 26 PLUGGED TUBE X

2 TUBE WITH WEAR INDICATION 110 105 100 95 9Q C

85 80 75 0oooo00oooopooo0 cOcDOo,..

i....

i....

70 65 60 55 50 45 40 35 30 25 20 15 10 0000 T

0 OOOO IO 0001 O

o I.o(

o o000 on 0.

.001..

5 oo 1.......

-v 45 1

1.

35 25 20 15

- =

=

=

-=

=

00 I

0 00 00.0 a

0....

0 oo.

T...

° 0ooI I

00 a

0 a 13o:

1:::

oo.

n.

o....

.... o o.

.T :..........0 o0...

()..o

.o I..
0.

0...

01...

I.

1 3...

o....

.0...

0 0..

0000oo:

00 0..

t 0

0.....

00 00......

0....

0..

0. 0 0....

0 0

0....

D0 000.000 000 00 0000.

DO Io I

I::::

S...............................

0o.

.0 000000

.0 00...........

°..

,00 00 0... 0.................. 0 0

00..

0 0(0 00)00 00000*00001:

1 0:

0-0 0

..........0...

0 C........................................

,T

.......1..

t.......

0.

..0

....0..

i I -

-1 I

oo~~~~~~1

=+

0t...........

  • +...
` ::

0o..

-0 0

0 oo...

0 00 o o...!

T..

........ "...T........

,..oo 0

i :i 00............

oo.

..o o.

0000 0

?

+

__..o 00

.()

00.

l O

.i.

f...

.. 00 I

--e 35

+-Ik L}

25 15 10 5

5 0...

0,.

0000 10 00oToooo000 OOOOO0000(

lie 105 100 95 i~~

~

10-1 0::I::::!..

85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

P0000 90 Westinghouse Electnc Company LLC - ST Max 10/22/2009 20:28:54

SG -

D PREHEATER WEAR INDICATIONS Braidwood 2 A2R14 CDE 20091001 10/22/2009 12:12:47

+°-

+--+--

÷....

-+--

-+-+

÷

-4......

+

I INSPOATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

+----+----+----

÷-+

+-

+..÷..--+

49 53 1.67 0

PCT 12 P6 07C

.00 TEC TEH

.610 ZBAZC 93 HI 2008/04/01 49 53

.34 93 VOL P4 07C

.11 07C 07C

.610 ZPSNN 2

Cl 2008/04/01 49 53 NOD TEH TEH

.610 ZPSNN 47 HI 2008/04/01 49 53 5.94 183 DNT P1 AV2

.00 TEC TEH

.610 ZBAZC 77 HI 2008/04/01 49 53 6.25 185 DNT P1 AV3

.00 TEC TEH

.610 ZBAZC 77 HI 2008/04/01 49 53 1.91 0

RWS P2 07C

.53 TEC TEH

.610 ZBAZC 77 HI 2008/04/01 49 53 1.45 0

PCT 15 P6 07C

.00 TEC TEH

.610 SBACC 127 HI 49 63 3.48 0

PCT 32 P6 07C

.05 TEC TEH

.610 ZBAZC 93 HI 2008/04/01 49 63

.81 85 VOL P4 07C

.24 07C 07C

.610 ZPSNN 2

CI 2008/04/01 49 63 NDF 2

TEH

.47 TEH TSH

.610 ZPSNM 9

HI 2008/04/01 49 63

.67 0

PCT 13 P2 AV4

-. 03 TEC TEH

.610 ZBAZC 81 HI 2008/04/01 49 63 3.50 0

RWS P2 07C

.56 TEC TEH

.610 ZBAZC 81 HI 2008/04/01 49 63 3.00 0

PCT 30 P6 07C

.56 TEC TEH

.610 SBACC 127 HI

+----

+..----+----

+-

+--------+----+----+----

+----+-

+-

+-

CA-+L -+

I INSPDATE ROW COL VOLTS DEG IND PER CHN LOCN INCHI INCH2 BEGT ENDT PDIA PTYPE CAL LI

÷...........

+

+....-------..

+----.

+--

+--

Tubes: 2 Records: 13 1

ST Max

Attachment B.7 Tubes Repaired During A2R14

SG-B TUBE TO BE STABILIZED AND PLUGGED IN THE HOT LEG Braidwood A2R14 CDE D5 1

1 TUBE TO BE PLUGGED IN THE HOT LEG 4 TUBE TO BE BTARILIZE)

ANM PLUGGED IN THE HOT L o 49 EXISTING PLUGGED TUBE 110 105 100 95 90 85 80 75 70 65 60 I 0000(P0000p00o00p0000c(P000n§00 a a...

4....

.... i.... io 0

0 0

0 55 50 45 00" f77{ 000 40 35 (D0000100000 a 1 ::

1j:

1: :

30 25 20 15 10 5

45 40 35 25 20 15 10 5

anIan.....................~i~oe 0

0....

  • ........a an.......
a.

0 0.........................................

a O 00..

.0.

0.......

00 0-...0.

.O O.......O.......0 0

0 0

0o..-..

OO.

O.O....

O...0 0..

()O.....

00 no.

  • .00..............................*:
0,,*

0 0................................0010- ::

0....

00...........

0 0..

0 0

0 0.....

.00 0

O

-ýe 0-00..............000...

000 0-.........

O00@0-.........................

00 00..

0 0..

............... 00 0

.... =*

0 0*.

.*=:=:**:::*..

O 0-O O..

O0 0)OO O)OOO O O..

O..0 O

00..........

0 0.....

0.........

  • .e e
  • e *

.0 0

0 00...................................................

. f....

f 0

0..

f.....*....

  • ..........................00 O

CC C

eCe e

CC

0. O

.. 0.....-...

.OOO..00....

000000 0000 0000........

0 O)... 0 00..

0......

-.....00

,00 0..........

"00 0.......

-.....0..

  • ).00 0.........................................................................
:,..................................0 Q0................................

a..

..... 0000 0000 0000T0000 0000.....................................

........ 0(

0,.

1 00 I....

0 0

0 0

'.11,0 0......*...............

..... 0 0.....................................................................................

0 00........0,0...........

.000...........................

4 0000.....................

0"0,0............

0*0........0 C --

C1 CC

~-

-T-0..........

00...............

0..........................1 0

0...................

0......................0(0........0 0..........................

.... 000...................

0000................

(0(00.......................0 0.........................................................................

I....................0 00........................................................................................................................

I.........

......00 35 45 25 15 10 5

00o:

I:

0.

0000 0

)0000(

00000ooq0oooo0pooo00000(Ppoo1o0o0 0000000000000(pooo0q)0000$0000000000000000000 0000qP0000/p0o00/0o000o0o00

,0000 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Weafnghouse Electric Com~pany LLC

- ST Max 10/2212009 20122:56

SG-B TUBE TO BE PLUGGED IN THE COLD LEG Braidwood A2R14 CDE D5 a 5 TUBE TO BE PLUGGED IN THE COLD LEG 0 49 EXISTING PLUGGED TUBE 110 105 100 95 90 85 80 75

. 00 00.,

0000 70 (O000C 65 60 55 50 45 40 35 30 25 20 15 10

)000000 0

cf 0000¶(OO00001 0

(01o 00:t

"".. TT TTt"*-:_{

I::::

45 5

45 AL~

a a ao.

00..

.0...

IOU-.

{.

10...

0 0

0 0

0 0

U 0

0n

-00 00(

40 35 25 20 15 0.

F0 0 '........

I00 o....

I0 00.................................

o....

oo..........

oo

°°.

°"

,,°-0

ý.

-o..

°°

o.

°,

O.

.0-0 00..

.. 00..

0..

0 O

00....

fo 00......

00 0.0 000....

0.......0 00 0

0......

.0 o.......

T...

0o 0

0 1.........

0.....

.I 0

1....

oo 0'.....

0o 0.

00 0

-........0000 0000

(

)00 00000.

. 0 0

00".

.'00().-

O 0

0 O00 0000.

0 I

  • ooo oo..oo.....

0I ° "

(D i

I I.

o.

. T.

.. l..

0 0

T.......

.I 0

0 00 00°...

".......'.. °

..... *.... T....

00:*

:..o 0

.o 0o o....0o o

.... T..

o,

000oo.....

o..

.. T..

0.....

0

... i..

.0.. :: : : "

r......

0.

... T.... 1 o-on....

.I.

..T..

I I

."...... on 40 35 25 20 15 10 5

5 0.°.

0000 1..l.

.... i........

.................0

'*," " II T..

T..

I

, I.

I I

' ° 0 00 U 010 00500 0 01 0000 8500(

0000 75000*

00' 00006 0000 0000 50 0

350 30000 0000 150ooo oo

  • ooo10 5oo oooo 110 105 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5

Westinghouse Electric Company LLC -ST Max 1012212009 20:22:44

SG B Plugged During A2R14 SG Outage InspDate Row Col Ind Per Volts Deg Chn Locn Inchl Inch2 BegT EndT PDia PType Cal Cm I L*

'U 2B A2R14 2B A2R14 28 A2R14 2B A2R14 2B A2R14 2B A2R14 10/1/2009 13 10/1/2009 13 10/1/2009 13 10/1/2009 13 10/1/2009 13 10/1/2009 13 10--/2009 ----

38 PCT 18 0.15

  • 38 SVI

'0.1 38 TBP 38 DFS 0.2 38 DFI 0.62 38 NDD 12~

17i 3

2 P4 2

07H

-0.7 07H

-0.7 08C 3.52 05H 34.98 8

0 05H 07H -

07H TEC TEC TSH 07H 07H 07H TEH TEH TSH 0.61 NPSNM 0.61

- NPSNM 0.61 NPSNM 0.61 ZBAZC 0.61 ZBAZC 0.61 NPSNM 113 113-113 53 RESULT 53 RESULT 1

Monday, January 18, 2010 Page I oj'l

SG B Plugged During A2R14 SG Outage InspDate Row Col Ind Per Volts Deg Chn Locn Inch] Inch2 BegT EudT PDia PType Cal Cm l 2B 2B 2B 2B 2B A2R14 A2R14 A2R14 A2R14 A2R14 10/1/2009 30 56 PCT 10/1/2009 30 56 SVI 10/1/2009 30 56 TBP 10/1/2009 30 56---

10/1/2009 30 56 DSI 10/1/2009 30 56

'NDD 15 0.11 281 0.1 76 0.16 56 07H 07H-

-0.74

-0.77 07H 07H 07H 07H 07H 07H TEC TEH TSH TSH 0.61 0.61 0.61 0.61 0.61 NPSNM NPSNM NPSNM ZBAZC NPSNM 111 111 111 61 5

RESULT P1 07H

-0.63 Monday, January 18, 2010

- ý I-Page I qj'I

SG B Plugged During A2R14 SG Outage InspDate Row Col Ind Per Volts Deg Chn Locn Inch] Inch2 BegT EndT PDia PType Cal C111 I U

2B 2B 2B 2B A2R14 A2R14 A2R14 A2R14 10/1/2009 21 65 PCT 10/1/2009 21 65 SVI 10/1/2009 21 65 TBP 10/1/2009 21 65 DSI 34 0.37 0.28 0.22 264 P1 05H

-0.63 05H 263 P4 05H

-0.64 05H 2

05H 51 P1 05H

-0.63 TEC 05H 0.61 NPSNM 05H 0.61 NPSNM 05H 0.61 NPSNM TEH 0.61 ZBAZC 111 111 111 65 RESULT Monday, January 18, 2010 Page I of I

SG B Plugged During A2R14 SG Outage InspDate Row Col Ind Per Volts Deg Chn Locn Inch] Inch2 BegT EndT PDa PType Cal Cm I 2B 2B 2B 2B 2B A2R14 A2R14 A2R14 A2R14 A2R14 I

10/1/2009 19 11/200-9 19--

10/1/2009 19 10/1/2009 19 10/1/2009 19 1

67 67 67 67 67 PCT SVI TBP DFI NDD 19 0.17 0.15 0.41 94 92 158 2

P4 2

1 05H

-0.78 05H

-0.79 05H

-0.88 05H 05H 05H TEC TSH 05H 0.61

' NPSNM

-05H 0.61

-NPSNM "

05H 0.61

' NPSNM TEH 0.61 ZBAZC TSH

" 0.61 NPSNM 111 111 111 65 7

'RESULT Monday, January 18, 2010 Page I oJl]

SG B Plugged During A2R14 SG Outage InspDate Row Col Ind Per Volts Deg Chn Locn Inch] Inch2 BegT EndT PDia PType Cal CmlI 2B A2R14 10/1/2009 41 45 PID 40 5.12 0

P2

' AV2 0

TEC TEH 0.61

' ZBAZC '

97 0

.61 2B A2R14j 10/1/2009 411 45 POT:3 :

41 53.0

- 0:

P2 AV3 0

TEC TEH

0.611 ZBAZC 59 2B-0 1/ 0 9--

4-45--

A-0-

MvIonday, january 18, 2U0U Page I of 1

SG-C TUBE TO BE STABILIZED AND PLUGGED IN THE HOT LEG Braidwood A2R14 CDE D5 1 TUBE TO BE A

PU-GGE0 IN THE a 65 PLUGGED TUBE E 0U AiN D 110 105 100 95 90 85 0000(

0 0o....

000 00.

80 75 70 65 60

~0000 0 P000$

000 000a0 00 55 50 45 40 35 9ooooToooo 30 25 20 15 10 5

0(

'0 000 a a 45 40 35 30 25 00............................a....i..

0

.00 0

0

............................ a 0.........

.............0 0 0..................

a 00 OO0............

l..

00 O IO..

0.o

00..................................

0 0.........

00 00l(.. 00.

0 0..

M:
M 00:: ::aO0 0..........0

............................... 01 00........0 0............0000.........

0........0 0....

..... 00.

. 0 0...

0 0

0.........

0 0...

..... 00.

.0.

E- --

e E

E a -

O e-() 9 00.................

....... 0(0a........... 0 0..........:00(0....................

..... 00 00........

0 0....

1 0.............................

0 0...........

0 00 -............................

0 0......................

00 ED E)

E) 0 0..........

00............................................0 0.............................

on

00.
  • 0.............

0 0 0..

.....................0

.0 0

0) 0E)E 0.......................

0...............0 0 0000 0000 0000 0000....

0 0...

0 0............................................................................

0 0.....................

a...............

0 0....

a.........

.... (0 00...........................................................................

a...

a...

.............. 0 0.....0 0......................0...................................

0 0...............................

00....

.........0 0........0 C

-C C-C--

0 -.....

0.............0..................................

....0............I........................0............. 0.....

00......................0 00.................

000..........

................00 0.........................................................................

0 0....

0 0......

Q 0

0)).........0 00.00000 00 15 5

0:

0 0

65 60 25 20 0

0 110 105 100 95 90 85 80 75 70 55 50 45 40 35 30 0000 400 000000 15 10 5

Westinghouse Electric Company LLC - ST Max 1=0222009 2026:07

SG-C TUBE TO BE PLUGGED IN THE COLD LEG Braidwood A2R14 CDE D5 1 TUBE TO BE PLUGGED IN THE COLD LEG a 65 PLUGGED TUBE 5

le 15 20 25 30 35 40 45 50 55 60 65 00000 OO O

OOMpaOpOOpOOp 0000 0000000000 00 00 0

a M I 0~

0a.~a.

aa 70 75 80 85 90 95 100 105 110 (1000000000$00000I 1

1 1

1 oc )0 000 4....

ý..00 45 40 25 00..........................

a....................00 00..............................

.0 n"0 a....................00 00.........A..............

0 0....................................a 0

  • 1.0................

0 00...............................0 0...........................

0

...0

.............. 0 0....

.00 0.......0.............................000...

0..

0000...

,..00..

0 M.0. O 0

0..

0

0.....

0 0...

00....... 00 00........

000.."

0 O00 a

0 0

0.

... 00 0'........

.0.............00

0.

I.....

0 0......

o.

..O 0 00.....

0 o0.....

... 00 C-

C0
C:.

O,

=

  • =

=

O C==

=

=

=

=

=

=

=

=

=

=

==

=

=

=

=

=

=

=

=

=

=

0 0 O...

00.........

0..........

-. 0 00O...

-)O O IO O )

O O)

O O)O....*

0., 0.

,*"00 00..............

'.....0 0000 ".."

-000..................

00......0 CC CC e.

C---

C

0)

CC aCCaEE 0*.-.0............00.........

.000000000 0000000000................

00..........0

  • 0 00,.*

0)0,-

0 0

0 O"::

0,,

,0 0'

,0 0

00.......'.............

...0 0

.00 0

0-(0.............

.... 1 0000110000 00000 0000 0000..............................

0.....................................................................

0T 0......................................a a..........................................................................

0........................................................

0 0........

0 0....................0*00.......................0000....................000.............

  • ,0*........0

-e C1 e--

e

~

C-

~-

-E-0.......0 0..................................0 0.....................0-.........

00......0 0..................

00...............

0000........................::(000...............

....... :::0 0...................................................

I..........

0 00..

t.........

a.............................0 0

45 40 35 25 15 15 10 5

5 0...

0...

0-00 20 25 30

ý:::: j::::

.. 0

-- 0

.. 0 50000 100000000' 5

10 15 41oooooooo41ooo41ooo41ooo41ooo41ooo41oooo1oooo4oooo41ooo41ooo41ooo41ooo41ooo40000 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 Westinghouse Electric Company LLC - ST Max 10I22/2009 20:25:55

SG C Plugged During A2R14 SG Outage InspDate Row Col Ind Per Volts Deg Chn Locn Inch] Inch2 BegT EndT PDMa PType Cal Cm I 2C A2R14 2C A2R14 2C A2R14 20 A2R14 2C A2R14 10/1/2009 10 3

SVI 0.14 88 P4 08H

-0.82 r

r r

10'1/2009 10 3

PCT 20 0.17 : 108; 2

-08H

-0.98 10/1/2009 10 3

TBP' 2

10/1/2009 10 3

DFI 0.41 164' 1

08H

-0.9 10/1/2009 10 3

NDD 07H 08H 0.61 07H 08H 0.61 07H 08H 0.61 TEC TEH 0.61 TSH TSH 0.61 NPSNM -

117 NPSNM 117 NPSNM : 117 SBACC 47

'RESULT NPSNM' 11

~

Alouday, January 18, 2010 Page 1 ti~f I Y, January 18, 2010 Page I of l