UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of

) )

CONSOLIDATED EDISON COMPANY

)

Docket No. 50-247 OF NEW YORK, INC.

)

(Indian Point Station,

)

Unit No. 2)

)

APPLICATION FOR AMENDMENT TO OPERATING LICENSE Pursuant to Section 50.90 of the Regulations of the Nuclear Regulatory Commission

("NRC"),

Consolidated Edison Company of New York, Inc.

("Consolidated Edison"),

as Holder of Facility Operating License No.

DPR-26, hereby applies for amendment of that license.

Specifically, Consolidated Edison requests that the License be amended to increase the authorized core power level from 2758 MWt to 3083.4 MWt and to allow operation at the higher power.

Additionally, Consolidated Edison requests that Section 2.C.1 of Facility Operating License and Technical Specifications, Section l.l.a, 2.3.1.B, 3.1.G, 3.4.A.2 and Basis Page 3.4-2 be amended accordingly.

The specific proposed Technical Specification revisions are set forth in Attachment A to this Application.

A Safety Assessment of the proposed changes is set forth in the Attachment B to this Application.

This assessment demonstrates that the proposed changes do not represent a significant hazards consideration as defined in 10 CFR 50.92(c).

As required by 10 CFR 50.91(b)(1), a copy of this application and our analysis concluding that the proposed changes do not constitute a

significant hazards consideration have been sent to the appropriate New York State official designated to receive such amendments.

BY:

/Vice President Nuclear Power Subscribed and sworn to before me thisjOday ANTHONYRARNONE of September, 1988 Notary Public, State of New Yor No. 4883047 Qualified in Westchester County Commission Expires January 26, 19 -/

Notar Ui 8810030304 8-0930 PDR ADOCK 05000247 P

PDC

Attachment A Facility Operating License and Technical Specification Page Revision Consolidated Edison Company of New York, Inc.

Indian Point Unit No. 2 Docket No. 50-247 September 30, 1988

0 0

SREXH RATIG PAM SrMARY OF OPERATIG 1ICENSE AND TEQ4IW L SPEFCIA1ONI HGS FR INDIAN POINT 2 PASECI DESCRIP=ION OF CNANGES 4

2.C.1 Change the value of authorized power level in the operating license.

1-1 l.l.a anged value of rated poe fro 2758 to 3071.4 IMt.

Inreased core power rating.

Note that Rated Power does not include pump heat from the RCPs. Rated NSSS power, which includes punp heat, is 3083.4 M~t.

Rated NSSS power does not appear in the Tech Specs.

DQIr't OF CHANGES 2.3-2 2.3.1.B Cared both nominal Tavg (T') in the OITT equation, and indicated Tavg (T ') in the OPdT equation to < or = 579.7 deg F.

3.1.G-1 3.1.G Inareased allowable Tavg to 585.5 deg. F.

A higher Tavg is allowed at the uprated power level.

he difference between allowable values reflects a 5.8 degree uncertaity ch~arged against rod control system.

DEmRIIION OF COANGE 3.4-1 3.4.A.2 The mininLn reuied auxiliary feedwater pump capacity is increased to 380 gpm per PUMP Heat removal requirments are increased with the higher power level.

The nw value for minimu flow reflects the flow used in the safety analyses.

0 rF"'RIPTON OF CAGE 3.4. Basis Percentage of total secondary flow is

-ed due to increased total secoary flow.

Also, the NSSS power level is changed to 3083.4 NSSS M t.

REASN Reflect uprated values of NSSS power and steam flow.

3.4-2