From:
Sreenivas, V Sent:
Thursday, January 28, 2010 9:46 AM To:
tom.shaub@dom.com; tom.szymanski@dom.com; david.summer@dom.com Cc:
Kulesa, Gloria; Cotton, Karen; Phalen, Martin; Blechman, Paula
Subject:
SURRY AND NORTH ANNA POWER STATIONS, REQUEST FOR ADDITIONAL INFORMATION REQUEST FOR ADDITIONAL INFORMATION (RAI) FOR SURRY (SPS) AND NORTH ANNA POWER STATIONS (NAPS)
(TAC NOS. ME2835, ME2836, ME2828 AND ME2829)
- 1. Attachment - 1, page 6 of 11, the first paragraph of item Intertek Heat and Flame Assessment states that:
Dominion obtained a new Fire Hawk Self-Contained Breathing Apparatus (SCBA) from Mine Safety Appliance Company (MSA) and charged it with 35/65 at SPS. This SCBA was then sent to Intertek to have a Heat and Flame Resistance test performed per NFPA 1981. The tested SCBA used a fully pressurized 4500 psig cylinder so as to bound all Dominion applications (i.e., low and high pressure) and was equipped with a HYCAR rubber Ultra Elite facepiece. (Note: Silicone facepieces fail Chemical, Biological, Radiological, Nuclear (CBRN) testing and were therefore not considered by Dominion for use due to site fire and security commonality considerations.) Please provide a commitment to ensure that only the HYCAR rubber facepieces with Fire Hawk SCBAs charged with 35/65 air will be used at SPS and NAPS.
- 2. Attachment - 2, page 5, section 5.0 Recommendations states that if the following recommendations are implemented, there are no fire hazards associated with the use of this equipment. Specifically:
- a. The presence of hydrocarbon contaminants in components such as the flex hoses could lead to bum out due to rapid pressurization ignition. Therefore, it is recommended to ensure that the SCBA's are not contaminated with hydrocarbons.
- b. It is recommended that if any of the Cylinder Valves become difficult to seal, the valves are removed and replaced. These valves must not be used to throttle the system as this can lead to seat damage and increase the risk of ignition.
- c. It is recommended to ensure that this component is not contaminated with hydrocarbon contaminants to reduce the risk of ignition by rapid pressurization.
- d. It is recommended that if this regulator becomes difficult to fully close, it is removed and replaced. (lst Stage Regulator)
Please submit a copy of MSA Firehawk Vendor manual or guidance document and Dominion's commitment to ensure compliance with use, maintenance, care, cleanliness, and repair protocols as per the document, and all applicable NIOSH requirements (i.e. fittings, materials, use, etc.) excluding the requirement for using Grade D quality breathing air.
- 3. As per Intertek Tests, please provide the heating and flame resistance test performed temperature, in degrees Fahrenheit.
Please submit the docketed response to these RAI's by February 15, 2010.
Docket Nos. 50-280, 50-281 for SURRY and 50-338, 50-339 for NAPS V. Sreenivas, PH.D., C.P.M.,
Project Manager, Rm.#O8F6, LPL2-1 North Anna Power Reactors, Units 1 and 2 Division of Operating Reactor Licensing-NRR (301) 415-2597, v.sreenivas@nrc.gov
- This email message, and any files transmitted with it, may contain confidential, non-public, sensitive and proprietary data intended solely for the person(s) to whom this email message is directly addressed. Unauthorized use of the data contained in this message is prohibited. If you are not the intended recipient of this message or have received this message in error, please notify the sender immediately by telephone or email Reply and delete the original message and any attachments without keeping a copy***
E-mail Properties Mail Envelope Properties (AF843158D8D87443918BD3AA953ABF780A40DBADC3)
Subject:
SURRY AND NORTH ANNA POWER STATIONS, REQUEST FOR ADDITIONAL INFORMATION Sent Date: 1/28/2010 9:46:00 AM Received Date: 1/28/2010 9:46:00 AM From: Sreenivas, V Created By: V.Sreenivas@nrc.gov Recipients:
tom.shaub@dom.com (tom.shaub@dom.com)
Tracking Status: None tom.szymanski@dom.com (tom.szymanski@dom.com)
Tracking Status: None david.summer@dom.com (david.summer@dom.com)
Tracking Status: None Gloria.Kulesa@nrc.gov (Kulesa, Gloria)
Tracking Status: None Karen.Cotton@nrc.gov (Cotton, Karen)
Tracking Status: None Martin.Phalen@nrc.gov (Phalen, Martin)
Tracking Status: None Paula.Blechman@nrc.gov (Blechman, Paula)
Tracking Status: None Post Office:
HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 21412 1/28/2010 Options Expiration Date:
Priority: olImportanceNormal ReplyRequested: False Return Notification: False
Sensitivity: olNormal Recipients received: