ML100220938

From kanterella
Jump to navigation Jump to search
Data Sheet 1 for Pilgrim Nuclear Power Station, Checklist for Step 1 Review
ML100220938
Person / Time
Site: Pilgrim
Issue date: 03/30/2009
From:
- No Known Affiliation
To:
Office of Information Services
References
FOIA/PA-2010-0090
Download: ML100220938 (2)


Text

DATASHEET 1 DATASHEET 1: CHECKLIST FOR STEP 1 REVIEW Unit: 011VA1 A!Ide/

40,dr Date of submittal:

/3 /% 5

1. The minimum financial assurance (MFA) estimate pursuant to 10 CFR 50.75(b) & (c)

Did the licensee identify the amount of estimated radiological funds? Yes N_ _

No

2. The total amount of dollars accumulated at the end of the appropriate year ___0______
3. Schedule of-the annual amounts remaining to be collected _--
4. Assumptions used in determining rates of escalation in decommissioning costs, rates of earnings on decommissioning funds, and rates of other factors used in funding projections:
5. Any contracts upon Which the licensee is relying: Yes or No
6. Any modifications to a licensee's, method of providing decommissioning funding assurance:

Yes_____ or No

7. Any material changes to trust agreements:

Yes or No

)c If a change has occurred, the reviewer will document on this sheet that a change has occurred and identify the reviewer who will evaluate the change Review Performed By:

Date:

91 cJL(4c,,

Plant name:

Pilgrim Station Datasheet 2<,_.atasheet 3 Docket Number:

Year:

2008 2026 50-293

'-5 Month:

Date of Operation:

Termination of Operations:

12 3

Base Lx 2.16 Day 31 18 0.65 2.37 I

,MWth 1

986 ECI BWR 2028

$122,252,000 1

109.5 1-Pxj 1.649 IEL..1 0.13 11.805 1 1!5 1ax I

0.22 NRC Mimimum:

$517,805,781 Step I:

Earnings Credit:

Trust Fund Balance:

$550,290,000 I

Real Rate of IYears Left Total Real RateI Return per year. I in License I of Retarn:

I

=

2%

1 17.21 1

1.40620 1

Total Earnings i

$773,817,017 Does Licensee Pass:

YES I

Step 2:

Accumulation:

IReal Rate of Number of Annual Value of Annuity per yeam Return per year Payments:

Total Annuity:

I

$0 1

2%

0

$0 Reat Rate of Years remaining after Total Annuity Return per year annuity Total Step 2

$0 2%

0.00

$0 If annuity is not consistent, go to "Annuity" sheet Does Licensee Pass:

]

YES Total Step I + Ste

$773,817,017 "

Step 3:

Decom Period:

Total Earnings:

S773,817,017 I

4 Real Rate of Decom Total Real Rate Return per year Period:

of Return:

2%

7 0.14869 Total Earnings for Decom:

$57,527,750 I I$831,344,7671 Does Licensee Pass:

YES

+

Shortfall:

NO Signature:

Date: ? A. ()D Spreadsheet created by: Aaron Szabo and Shawn Harwell Fonnulas verified by: Larry Pittiglio