ML093431235

From kanterella
Jump to navigation Jump to search
Forwards Rev 2 to Procedure SOP-SG-2, Secondary Plant Chemistry Control & Rev 2 to Procedure RE-CS-12, Routine Chemistry Specs & Frequency, in Response to NRC & Discussion at 830429 Meeting
ML093431235
Person / Time
Site: Indian Point Entergy icon.png
Issue date: 05/03/1983
From: Bayne J
Power Authority of the State of New York
To: Varga S
Office of Nuclear Reactor Regulation
Shared Package
ML093431236 List:
References
IPN-83-33, NUDOCS 8305130117
Download: ML093431235 (1)


Text

POWER AUTHORITY OF THE STATE OF NEW YORK 10 COLUMBUS CIRCLE NEW YORK, N.Y. 10019 (212) 397-6200 LEROY W. SINCLAIR TRUSTEES PRESIDENT & CHIEF I

OPERATIN G OFFICER JOHN S. DYSON WALTER T. KICINSKI CHAIRMAN@

FIRST EXECUTIVE VICE PRESIDENT CHIEF ADMINISTRATIVE GEORGE L. INGALLS OFFICER VICE CHAIRMAN JOSEPH R. SCHMIEDER EXECUTIVE VICE RICHARD M. FLYNN PRESIDENT & CHIEF ENGINEER JAMES L. LAROCCA STEPHEN L. BAUM SENIOR VICE PRESIDENT ROLLAND E. KIDDER May 3,

1983

.GENEAL COUNSEL IPN-83-33 Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C. 20555 Attention:

Mr. Steven A. Varga, Chief Operating Reactors Branch No. 1 Division of Licensing

Subject:

Indian Point 3 Nuclear Power Plant Docket No. 50-286 Steam Generator Chemistry at Indian Point 3

Dear Sir:

In response to your letter of April 21, 1983 regarding the subject item and as a result of discussions held between members of your staff and representatives of the Authority at the April 29, 1983 meeting in Bethesda, Maryland, procedures SOP-SG-2, Rev.

2 ("Secondary Plant Chemistry Control") and RE-CS-12, Rev. 2

("Routine Chemistry Specifications and Frequency") are provided in Attachment A for your information and review.

Should you or your staff have any questions on this matter, please contact Mr. P. Kokolakis of my staff.

Very truly yours, d4 J.P. Bayne 0

Executive Vice President Nuclear Generation cc:

Resident Inspector's Office Indian Point 3 U.S. Nuclear Regulatory Commission P. 0. Box 66 Buchanan, New York 10511 8305130117 830503 PDR ADOCK 05000286 P

PDR