Attachment 6 OBDI 202 - IOLE Process DRAFT OUTLINE COMMENTS Facility:

WC First Exam Date:

8/26/09 Written Exam Outline 6/15/09 Comment Resolution 1 No fuel handling KAs Selected NOTE ONLY 2

3 4

5 Administrative JPM Outline 6/15/09 Comment Resolution 1

The RO and SRO topics are the same.

These need to be different. For example, the SRO would perform the review function, and the RO would perform the actual STP.

INFORMATION ONLY 2 Replace A.1.a and A.1.b for the SROs.

Leave them for the ROs.

Fixed 3 Change A2 for the ROs to perform some STP that the SROs will review.

Fixed 4

Change A3 for the SROs to evaluate radiological conditions while performing the emergency director function where a decision needs to be made.

Fixed 5 Re-label the JPMs SA1, SA2 for SROs; and RA1, RA2 for the ROs.

Fixed Control Room / In-Plant System JPM Outline 6/15/09 Comment Resolution 1 None.

2 3

4 5

OBDI 202 - IOLE Process Simulator Scenario Outline Comments 6/15/09 Comment Resolution 1 Scen 1, Event 1: Not a critical task. See NUREG-1021, Appendix D.

Fixed 2 Scen 1, Event 2: Not a critical task.

Fixed 3

Scen 1, Event 6: Restoring AC power is a critical task. Ensure there is a success path built into the scenario to restore AC power to one ESF bus.

Fixed 4

Ensure Tech Specs are clearly defined for each scenario on the ES-D-2 forms.

This must include all applicable TS and corresponding conditions. Ensure your ops department representative can make this definitive (ie. absolute, not well maybe). We usually see a TS(SRO) somewhere on the ES-D-1, but that is not required.

GENERIC COMMENT.

5 Scen 3, Events 3, 4, 6: Need to identify the type of malfunction and the applicable position that will get credit.

Fixed 6

Ensure there is sufficient detail in the ES-D-2s. This is not a copy-paste from the procedure unless the applicant will be performing those steps.

INFORMATION ONLY.