1 IPRenewal NPEmails From:

Green, Kimberly Sent:

Tuesday, November 10, 2009 11:26 AM To:

STROUD, MICHAEL D Cc:

IPRenewal NPEmails

Subject:

Draft Telecon Summary for Call Held on November 9, 2009 Attachments:

Telecon Summary 11-09-09 MACCS2 Met Data.doc

Mike, Attached is the draft telecon summary for the call that occurred on November 9, 2009, regarding the how the meteorological data were averaged. Please let me know if any corrections or changes are needed.

KimberlyGreen SafetyPM (301)4151627 kimberly.green@nrc.gov

Hearing Identifier:

IndianPointUnits2and3NonPublic_EX Email Number:

1850 Mail Envelope Properties (F5A4366DF596BF458646C9D433EA37D71D5EE3782D)

Subject:

Draft Telecon Summary for Call Held on November 9, 2009 Sent Date:

11/10/2009 11:26:23 AM Received Date:

11/10/2009 11:26:29 AM From:

Green, Kimberly Created By:

Kimberly.Green@nrc.gov Recipients:

"IPRenewal NPEmails" <IPRenewal.NPEmails@nrc.gov>

Tracking Status: None "STROUD, MICHAEL D" <MSTROUD@entergy.com>

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 345 11/10/2009 11:26:29 AM Telecon Summary 11-09-09 MACCS2 Met Data.doc 63994 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

DATE, 2009 LICENSEE:

Entergy Nuclear Operations, Inc.

FACILITY:

Indian Point Nuclear Generating Unit Nos. 2 and 3

SUBJECT:

SUMMARY

OF TELEPHONE CALL HELD ON NOVEMBER 9, 2009, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING METEOROLOGICAL DATA USED FOR THE SEVERE ACCIDENT MITIGATION ALTERNATIVE ANALYSES Representatives of the U.S. Nuclear Regulatory Commission (NRC or the staff) and Entergy Nuclear Operations, Inc., (Entergy or the applicant) held a telephone call on November 9, 2009, to clarify how the meteorological data that were used in the severe accident mitigation alternatives (SAMA) were averaged. This call was a follow-up call to the call held on November 3, 2009.

During the call, Entergy informed the staff that based on a review of the meteorological data used for the SAMA analysis it discovered an error in how the wind direction data were averaged. Entergy stated that it has issued a condition report. It further stated that it will document the discovery of the error and that corrective action is being taken in a letter to the NRC.

Entergy plans to submit the results of a reanalysis of the MACCS2 calculations using corrected data. The staff asked Entergy to also include the following information in its submittal:

identification of the wind data used and its justification (e.g., if a single year is used or an average of several years),

revised estimates of the offsite population dose and offsite economic costs, identify which meteorological tower locations and heights were used for wind data and why they were selected, an assessment of the impact on the SAMA analysis results, specifically for the analysis case discussed in response to RAI 4e, dated February 5, 2008, and the complete MACCS2 input file used for the reanalysis (in electronic format).

The enclosure provides a listing of the participants.

The applicant had an opportunity to comment on this summary.

Kimberly Green, Safety Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation

Docket Nos. 50-247 and 50-286

Enclosure:

As stated cc w/encl: See next page

DATE, 2009 LICENSEE:

Entergy Nuclear Operations, Inc.

FACILITY:

Indian Point Nuclear Generating Unit Nos. 2 and 3

SUBJECT:

SUMMARY

OF TELEPHONE CALL HELD ON NOVEMBER 9, 2009, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND ENTERGY NUCLEAR OPERATIONS, INC., CONCERNING METEOROLOGICAL DATA USED FOR THE SEVERE ACCIDENT MITIGATION ALTERNATIVE ANALYSES Representatives of the U.S. Nuclear Regulatory Commission (NRC or the staff) and Entergy Nuclear Operations, Inc., (Entergy or the applicant) held a telephone call on November 9, 2009, to clarify how the meteorological data that were used in the severe accident mitigation alternatives (SAMA) were averaged. This call was a follow-up call to the call held on November 3, 2009.

During the call, Entergy informed the staff that based on a review of the meteorological data used for the SAMA analysis it discovered an error in how the wind direction data were averaged. Entergy stated that it has issued a condition report. It further stated that it will document the discovery of the error and that corrective action is being taken in a letter to the NRC.

Entergy plans to submit the results of a reanalysis of the MACCS2 calculations using corrected data. The staff asked Entergy to also include the following information in its submittal:

identification of the wind data used and its justification (e.g., if a single year is used or an average of several years),

revised estimates of the offsite population dose and offsite economic costs, identify which meteorological tower locations and heights were used for wind data and why they were selected, an assessment of the impact on the SAMA analysis results, specifically for the analysis case discussed in response to RAI 4e, dated February 5, 2008, and the complete MACCS2 input file used for the reanalysis (in electronic format).

The enclosure provides a listing of the participants.

The applicant had an opportunity to comment on this summary.

Kimberly Green, Safety Project Manager Projects Branch 2 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-247 and 50-286

Enclosure:

As stated

cc w/encl: See next page DISTRIBUTION: See next page ADAMS Accession Number: G:\\ADRO\\DLR\\RPB2\\Indian Point\\Safety Review\\Telecon Summaries\\Telecon Summary 11-09-09 MACCS2 Met Data.doc OFFICE PM:RPB2:DLR LA:DLR BC:RPB2:DLR PM:RPB2:DLR NAME DATE 11/DD/09 11/DD/09 11/DD/09 11/DD/09 OFFICIAL RECORD COPY

ENCLOSURE TELEPHONE CONFERENCE CALL INDIAN POINT NUCLEAR GENERATING UNIT NOS. 2 AND 3 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS NOVEMBER 9, 2009 PARTICIPANTS AFFILIATIONS Kim Green U.S. Nuclear Regulatory Commission (NRC)

Bob Palla NRC Nate Bixler Sandia National Laboratory (SNL)

Joe Jones SNL Garry Young Entergy Nuclear Operations, Inc. (Entergy)

Alan Cox Entergy Mike Stroud Entergy Lori Potts Entergy Clem Yeh Entergy Kou John Hong Entergy Doug Gaynor Entergy Jim Thomas Enercon John Corn Enercon