L-03-002, Notification of Deletion of Commitment Made, 30-Day Response to NRC Bulletin 2003-02

From kanterella
(Redirected from ML092860612)
Jump to navigation Jump to search
Notification of Deletion of Commitment Made, 30-Day Response to NRC Bulletin 2003-02
ML092860612
Person / Time
Site: Prairie Island  Xcel Energy icon.png
Issue date: 10/09/2009
From: Schimmel M
Northern States Power Co, Xcel Energy
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
BL-03-002, L-PI-09-109
Download: ML092860612 (2)


Text

&

XcelEnergy-OCT 0 9 2009 L-PI-09-109 BL 2003-02 U S Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001 Prairie Island Nuclear Generating Plant Units 1 and 2 Dockets 50-282 and 50-306 License Nos. DPR-42 and DPR-60 Notification of Deletion of Commitment Made in the Prairie Island Nuclear Generating Plant (PINGP) 30-Day Response to NRC Bulletin 2003-02

References:

1. Letter from Nuclear Management Company, LLC (NMC) to NRC, "Nuclear Regulatory Commission Bulletin 2003-02: Leakage from Reactor Pressure Vessel Lower Head Penetrations and Reactor Coolant Pressure Boundary Integrity Day Response," dated September 19, 2003 (ML032690983).
2. "Notification of Change to Commitment Made in the Prairie Island Nuclear Generating Plant (PINGP) 30-Day Response to NRC Bulletin 2003-02," dated October 29, 2007 (ML073020242).

In Reference 1, the Nuclear Management Company, LLC (NMC 1) committed to perform a 100% bare-metal visual exam of the lower reactor pressure vessel (RPV) dome up to and including each bottom-mounted instrumentation (BMI) penetration to RPV junction each PINGP refueling outage. In Reference 2, the frequency of inspection was extended to every other refueling outage.

Since the creation of this commitment, ASME Section XI Code Case N-722 has been developed to provide requirements for bare metal visual examination of full and partial penetration welds in Class 1 components that are fabricated with Alloy 600/82/182.

Paragraph 10 CFR 50.55a(g)(6)(ii)(E) has been added to require all licensees to apply this code case with conditions.

Appropriate safety-significant visual inspections for the lower RPV dome have been incorporated into regulation via 10 CFR 50.55a(g)(6)(ii)(E). The commitment to perform this inspection is no longer required.

On September 22, 2008, NMC transferred its operating license authority to Northern States Power Company, a Minnesota Corporation (NSPM), doing business as Xcel Energy. By letter dated September 3, 2008, NSPM assumed responsibility for actions and commitments previously submitted by NMC.

1717 Wakonade Drive East e Welch, Minnesota 55089-9642 Telephone: 651.388.1121 40y7

Document Control Desk Page 2 Please contact Kathryn Mews (651-388-1121, ext. 7384) if you have any questions related to this submittal.

Summary of Commitments This letter makes no new commitments and deletes the commitment in Reference 2.

Mark A. Schimmel Site Vice President, Prairie Island Nuclear Generating Plant Northern States Power Company - Minnesota cc:

Administrator, Region Ill, USNRC Project Manager, Prairie Island, USNRC Resident Inspector, Prairie Island, USNRC