IR 05000171-09-007, on 08/12/2009, for Peach Bottom Atomic Power Station, Unit 1, Delta, PA, Safestor Inspection. Transmittal Letter
ML092540134
Person / Time
Site: Peach Bottom  
Issue date: 09/11/2009
From: Joustra J
Division of Nuclear Materials Safety I
To: Pardee C
Exelon Generation Co
References
IR-09-007
Download: ML092540134 (4)


See also: IR 05000171/2009007

Text

September 11, 2009

Docket No.

05000171

License No.DPR-1

Mr. Charles G. Pardee

Senior Vice President, Exelon Generation Company LLC

President and Chief Nuclear Officer, Exelon Nuclear

4300 Winfield Rd.

Warrenville, IL 60555

SUBJECT:

NRC INSPECTION REPORT NO. 05000171/2009007, EXELON GENERATION

COMPANY, LLC, PEACH BOTTOM ATOMIC POWER STATION, UNIT 1,

DELTA, PENNSYLVANIA

Dear Mr. Pardee:

On August 10-12, 2009, the U.S. Nuclear Regulatory Commission (NRC) conducted a safety

inspection at the Peach Bottom Atomic Power Station, Unit 1 of activities authorized by the

above listed NRC license. The inspection was an examination of your licensed activities as they

relate to radiation safety and to compliance with the Commission's regulations and the license

conditions. The inspection consisted of observations by the inspector, interviews with personnel,

and a selective examination of representative records. The findings of the inspection were

discussed with William Maguire of your organization, and members of the Exelon management

and staff on August 12, 2009, at the conclusion of the inspection. The enclosed report presents

the results of this inspection.

Within the scope of this inspection, no violations were identified.

In accordance with 10 CFR Part 2.390 of the NRCs Rules of Practice, a copy of this letter, its

enclosure, and your response (if any) will be available electronically for public inspection in the

NRC Public Document Room or from the Publicly Available Records component of the NRCs

document system (ADAMS). ADAMS is accessible from the NRC Web Site at

http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

No reply to this letter is required. Please contact Laurie Kauffman at (610) 337-5323 or

laurie.kauffman@nrc.gov if you have any questions regarding this matter.

Sincerely,

Original signed by Kathy Modes For

Judith A. Joustra, Chief

Decommissioning Branch

Division of Nuclear Materials Safety

Enclosure: NRC Inspection Report No. 05000171/2009007

w/Attachment: Supplemental Information

cc w/encl:

see next page

NUCLEAR REGULATORY COMMISSION

REGION I

475 ALLENDALE ROAD

KING OF PRUSSIA, PENNSYLVANIA 19406-1415

C. Pardee

2

cc w/encl:

C. Crane, President and Chief Operating Officer, Exelon Corporation

M. Pacilio, Chief Operating Officer, Exelon Nuclear

W. Maguire, Site Vice President, Peach Bottom

J. Grimes, Senior Vice President, Mid-Atlantic

R. Hovey, Senior Vice President, Nuclear Oversight

G. Stathes, Plant Manager, Peach Bottom

J. Armstrong, Regulatory Assurance Manager, Peach Bottom

J. Bardurski, Manager, Financial Control & Co-Owner Affairs

R. Franssen, Director, Operations

P. Cowan, Director, Licensing

D. Helker, Licensing

K. Jury, Vice President, Licensing and Regulatory Affairs

J. Bradley Fewell, Associate General Counsel, Exelon

T. Wasong, Director, Training

Correspondence Control Desk

D. Allard, Director, Bureau of Radiation Protection, PA Department of Environmental Protection

S. Gray, Administrator, Maryland Power Plant Research Program

S. Pattison, Secretary, SLO, Maryland Department of the Environment

M. Griffen, Maryland Department of Environment

Public Service Commission of Maryland, Engineering Division

Board of Supervisors, Peach Bottom Township

B. OConnor, Council Administrator of Harford County Council

Mr. & Mrs. Dennis Hiebert, Peach Bottom Alliance

E. Epstein, TMI - Alert

J. Johnsrud, National Energy Committee, Sierra Club

Mr. & Mrs. Kip Adams

R. Fletcher, Dir, MD Environmental Program Manager, Radiological Health Program

Director, Nuclear Safety Project, Union of Concerned Scientists

R. Ayers, Deputy Mgr, Harford County Div of Emergency Operations

E. Crist, Harford County Div of Emergency Operations

S. Ayers, Emergency Planner, Harford County Div of Emergency Operations

R. Brooks, Cecil County Dept of Emergency Services

Commonwealth of Pennsylvania

September 11, 2009

Docket No.

05000171

License No.

DPR-12

Mr. Charles G. Pardee

Senior Vice President, Exelon Generation Company LLC

President and Chief Nuclear Officer, Exelon Nuclear

4300 Winfield Rd.

Warrenville, IL 60555

SUBJECT:

NRC INSPECTION REPORT NO. 05000171/2009007, EXELON GENERATION

COMPANY, LLC, PEACH BOTTOM ATOMIC POWER STATION, UNIT 1,

DELTA, PENNSYLVANIA

Dear Mr. Pardee:

On August 10-12, 2009, the U.S. Nuclear Regulatory Commission (NRC) conducted a safety

inspection at the Peach Bottom Atomic Power Station, Unit 1 of activities authorized by the

above listed NRC license. The inspection was an examination of your licensed activities as they

relate to radiation safety and to compliance with the Commission's regulations and the license

conditions. The inspection consisted of observations by the inspector, interviews with personnel,

and a selective examination of representative records. The findings of the inspection were

discussed with William Maguire of your organization, and members of the Exelon management

and staff on August 12, 2009, at the conclusion of the inspection. The enclosed report presents

the results of this inspection.

Within the scope of this inspection, no violations were identified.

In accordance with 10 CFR Part 2.390 of the NRCs Rules of Practice, a copy of this letter, its

enclosure, and your response (if any) will be available electronically for public inspection in the

NRC Public Document Room or from the Publicly Available Records component of the NRCs

document system (ADAMS). ADAMS is accessible from the NRC Web Site at

http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

No reply to this letter is required. Please contact Laurie Kauffman at (610) 337-5323 or

laurie.kauffman@nrc.gov if you have any questions regarding this matter.

Sincerely,

Original signed by Kathy Modes For

Judith A. Joustra, Chief

Decommissioning Branch

Division of Nuclear Materials Safety

Enclosure: NRC Inspection Report No. 05000171/2009007

w/Attachment: Supplemental Information

cc w/encl:

see next page

Distribution

See next page

DOCUMENT NAME: G:\\WordDocs\\Current\\Insp Letter\\LDPR-12.2009007.doc

SUNSI Review Complete: JJoustra

After declaring this document AAn Official Agency Record@ it will be released to the Public.

To receive a copy of this document, indicate in the box: AC@ = Copy w/o attach/encl AE@ = Copy w/ attach/encl AN@ = No copy ML092540134

OFFICE

DNMS/RI

N

DNMS/RI

DNMS/RI

NAME

LKauffman/LKauffman

JJoustra/KDM f JAJ/

DATE

09/10/2009

09/11/2009

OFFICIAL RECORD COPY

C. Pardee

2

Distribution:

S. Collins, RA

M. Dapas, DRA

D. Lew, DRP

J. Clifford, DRP

J. Kinneman, DNMS

D. Collins, DNMS

J. Joustra, DNMS

L. Kauffman, DNMS

P. Krohn, DRP

R. Fuhrmeister, DRP

A. Rosebrook, DRP

E. Torres, DRP

J. Bream, DRP

F. Bower, DRP, SRI

M. Brown, DRP, RI

S. Schmitt, DRP, OA

L. Trocine, RI OEDO

H. Chernoff, NRR

R. Nelson, NRR

J. Hughey, PM NRR

P. Bamford, Backup NRR

K. Banovac, FSME

D. Persinko, FSME

ROPreports@nrc.gov