ML092360406
| ML092360406 | |
| Person / Time | |
|---|---|
| Site: | Calvert Cliffs |
| Issue date: | 08/17/2009 |
| From: | Flaherty M Calvert Cliffs 3 Nuclear Project, Constellation Energy Group, Nuclear Generation Group |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML092360406 (2) | |
Text
Calvert Cliffs Nuclear Power Plant 1650 Calvert Cliffs Parkway Lusby, Maryland 20657 Constellation Energy
,Nuclear Generation Group August 17, 2009 U. S. Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:
SUBJECT:
Document Control Desk Calvert Cliffs Nuclear Power Plant Unit No. 2; Docket No. 50-318 Spring 2009 - 180 Day Steam Generator Report
REFERENCE:
(a)
Calvert Cliffs Nuclear Power Plant Units 1
Specification 5.6.9 and 2
Technical In response to Reference (a), Attachment (1) provides the results of the steam generator tube inspection conducted on Calvert Cliffs Unit 2 in 2009.
This report includes the number and extent of tubes examined and indications identified.
Should you have questions regarding this matter, please contact Mr. Jay S. Gaines at (410) 495-5219.
Very truly yours, Mark D. Flaherty Manager - Engineering Services MDF/RDW/bjd
Attachment:
(1)
Calvert Cliffs Unit 2, Spring 2009 - 180 Day Steam Generator Report cc:
D. V. Pickett, NRC S. J. Collins, NRC Resident Inspector, NRC S. Gray, DNR A(Do (
I I
d ATTACHMENT (1)
CALVERT CLIFFS UNIT 2, SPRING 2009 -
180 DAY STEAM GENERATOR REPORT Calvert Cliffs Nuclear Power Plant, Inc.
August 17, 2009