ML091671782

From kanterella
Jump to navigation Jump to search
Final Table Showing Numbers of Adult Tiger Beetles within Sections of the Shoreline at Calvert Cliffs Sites
ML091671782
Person / Time
Site: Calvert Cliffs  
Issue date: 06/12/2009
From:
- No Known Affiliation
To:
Office of New Reactors
Quinn, L, NRO/DSER/RAP2, 301-415-2220
References
Download: ML091671782 (3)


Text

Table 7. Numbers of adult C. puritana and C. d. dorsalis within sections of the shoreline at Calvert County Sites, 2004-2007. Map points correspond to points included on topographics maps in appendix of report Map 2008 2007 2006 2005 2004 2008 2007 2006 2005 2004 Points C.dor C.dor C.dor C.dor C.dor. C.pur pur pur C.pur. C.pur.

Shoreline Notes// bold is 2007 notes LAT LON Randle Cliffs 1

0 0

0 0

0 7

0 0

0 0

public beach area, then cliffs begin; water level very high in 2005 4282206.00 366690.00 2

0 0

0 0

0 0

0 0

0 0

start main area of tall cliffs, very narrow, no beach 4282170.00 366700.00 3

0 0

0 0

0 0

0 0

0 0

same 4282169.00 366702.00 4

0 0

0 0

0 3

2 2

4 8

New breakdown area in 2005 4282063.00 366728.00 5

0 0

0 0

0 2

3 5

3 3

same, small sections of sandy beach 4281983.00 366763.00 6

0 0

0 0

0 0

0 0

18 0

same 4281923.00 366766.00 7

0 0

0 0

0 4

3 4

0 0

1-2 m wide, poor beach habitat; cliffs ok 4281870.00 366783.00 8

0 0

0 0

0 1

3 2

0 5

start breakdown with wider beach 4281857.00 366740.00 9

0 0

0 0

0 0

1 0

0 0

same but no beach; new sandy breakdown, mid height cliffs, dry 4281746.00 366806.00 10 0

0 0

0 0

1 0

1 2

8 wide, 3-4 m beach patch, then narrow; dry cliffs, small patch of beach 4281654.00 366832.00 11 0

0 0

0 0

1 4

1 2

3 narrow, no beach, even at mid-tide 4281501.00 366838.00 12 0

0 0

0 0

4 5

3 2

0 beach ends, no beach accessible to south, all v. narrow; breakdown at end 4281333.00 366857.00 0

0 0

0 0

23 21 18 31 27 Camp Roosevelt 13 0

0 0

0 0

0 0

0 0

Start at north end at stream entry, no cliffs then wood area, then tall dry cliffs 14 0

0 0

0 0

0 0

0 0

South end of site 0

0 0

0 0

0 Bayside Forest 15 0

0 0

0 0

0 0

0 N of BF, at Plum Point, at yellow house with lawn ornaments 4274428.23 368278.79 16 0

0 0

0 0

0 0

0 start series of white houses and no cliffs, some houses damaged by Isabel ?

4274050.32 368201.05 17 0

0 0

0 0

0 0

0 few small groins, cliffs fully vegetated, low, then wooded cliffs, trailor park 4273717.98 368134.07 18 0

0 0

0 0

0 0

0 creek, rock rip-rap, road bed to beach, 4273392.07 368107.36 19 0

0 0

0 0

0 0

0 start high cliffs, no suitable strata 4273246.13 368085.87 20 0

0 0

0 0

0 0

0 dry cliffs, most with vegetation 4272931.63 368026.85 21 0

0 0

0 0

0 0

0 0

0 cliffs end, marsh, creek entry, then woods, then low cliffs 4272475.73 367933.77 22 0

0 0

0 0

0 0

0 0

0 poor low, vegetated cliffs, breakdown; main survey area here to south+D61 4272131.05 367894.37 23 0

0 0

0 0

0 0

0 0

0 very tall cliffs, thin section of soft strata 4271673.71 367901.97 24 0

0 0

0 0

0 0

0 0

0 tall cliff section, narrow beach, many C. repanda 4271513.65 367901.33 25 0

0 0

0 0

0 see 0

0 0

pier posts in water, then no cliffs, then hard, marl cliffs 4271207.36 367883.21 26 0

0 0

0 0

0 to 0

0 0

cliffs dry, many fallen trees, then veg. cliffs 4270886.91 367855.87 27 0

0 0

0 0

0 right 0

0 0

same 4270884.91 367855.84 28 0

0 0

0 0

0 0

0 0

0 no cliffs, woods, then low cliffs; many C. hirticollis 4270696.80 367846.63 29 0

0 0

0 0

0 0

0 0

0 low cliffs, field behind, most cliffs bare, 20-25' high 4270437.65 367844.09 30 0

0 0

0 0

0 3 3*

0 0

start cliffs, lots of trees down, equipment and tracks; many C. hirticollis 4270322.93 367847.95 31 0

0 0

0 0

5 9 3*

2 0

road access, no cliff section 4270138.63 367883.34 32 0

0 0

0 0

0 1

0 0

0 low bare cliffs, very wide beach (due to 2004 erosion) 4269824.88 367927.75 33 0

0 0

0 0

0 1

0 0

0 Bayside Forest: south end access, low cliffs, evidence of severe erosion, cutback 4269741.77 367925.50 0

0 0

5 14 6

2 0

  • Note that these numbers were incorrectly placed further north in previous reports Warrior Rest N of 33a 0

0 0

3 Cliff section north of Parker Creek mouth 4266573 367708 33a 0

0 0

0 3

12 Far N end, start at beginning of cliffs, S edge of beach (no waypoint) 4266344 367687 33b 0

17 55 182 4266059 367729 34 0

0 96 48 34 13 Near N. end, no access for last 300 meters of cliffs habitat, severe erosion 4266119.45 367764.62 35 0

0 133 111 275 44 Good cliffs 4265995.33 367799.37 36 0

0 341 160 394 47 same; creek entry 4265795.36 367829.99 37 0

0 131 88 222 7

good cliffs, narrow beach 4265649.67 367873.71 38=39 0

0 240 171 275 31 continue tall cliffs; some vegetated cliff sections, 4265544.85 367896.40 0

0 958 633 1388 154 Scientists Cliffs 40 0

0 0

22 25 0

6 26 at creek entry and cove; last groin, tall cliffs begin 4265331.95 367963.69 41 0

0 0

0 5

0 2

3 narrow, no cliff habitat 4265159.36 367995.99 42 0

0 0

0 4

0 2

0 same, no cliff habitat, beach narrows 4264839.36 368062.58 43 0

0 0

9 56 60 2

2 wider beach 6-8 m; old or broken groins, end at creek entry, driveway to beach 4264568.17 368130.93 44 0

0 0

25 18 8

4 16 section of rip rap; same low, veg. cliffs 4264327.43 368210.95 45 0

0 0

55 4

12 11 20 same; new gabion in 2005 4264219.09 368244.75 46 0

0 0

13 8

1 0

6 continue groins, low or vege cliffs 4263920.84 368332.12 47 0

0 0

11 10 9

0 0

same, groins 4263758.76 368380.74 Specific locales,"07): 2 at 8450, 2 at 8425, 6 at 8383, 3 at 8359, 1 at 8302, 4 at 8247, 18 at 8235(just S of stream channel); 56 from 8235 to 8200; 1 at 8119, 3 at 8036, 5 from 8018 to 8000, 25 from 7980 to 7964, 7964 to 7946, 12 from 7964 to to 7946, 135 from 7946 to 7896, 88 from 7896 to 7873, 160 from 7883 to 7829, 111 from 7829 to 7800, 48 from 7800 to 7770; quit no access 48 0

0 0

0 0

0 1

8 20 6 groins,gabion, creek entry, low vegetated cliffs, ORV tracks 4263486.71 368474.83 49 0

0 0

0 0

0 0

0 0

groins end, beach narrows; ORV tracks 4263264.68 368571.49 50 0

0 0

0 0

0 0

0 0

SC North, S end,public beach rock groin, 10-12 m wide beach; heavy beach use 4263137.40 368636.56 51 0

0 0

0 0

0 0

2 0

Start Scientist Cliffs South, beginning of north end, groins 4263127.00 368621.00 52 0

0 0

1 2

4 0

5 open face cliffs, groins; 3rd, 4th gabions 4262981.00 368641.00 53 0

0 0

2 0

2 2

3 semi-vegetative cliffs, groins; most veg. cliffs 4262915.00 368665.00 54 0

0 0

3 3

19 9

8 semi-vegetative cliffs, end of groins; wide with breakdown bank 4262820.00 368708.00 55 0

0 0

7 16 18 16 12 open face cliffs(last groin at 8715) 4262758.00 368723.00 56 0

0 2

0 3

8 56 29 50 open face cliffs near waterline, 4262698.00 368749.00 57 0

0 0

34 34 18 12 12 same 4262638.00 368776.00 58 0

0 0

33 13 5

6 71 same, cliffs ending 4262564.00 368815.00 59 0

0 0

0 26 rock groin and residence, no open cliffs,far south end 4262435.00 368892.00 0

0 2

0 218 206 213 111 280 Western Shores/Calvert Beach 60 0

0 0

1 0

0 0

0 0

0 north end of public beach 4261318.48 369396.39 61 0

0 1

0 0

0 0

0 0

0 narrow beach, ends at creek entry 4261219.24 369451.65 62 0

2 76 3

12 0

0 0

0 0

very narrow beach 4261067.20 369531.54 63 0

6 18 18 30 0

0 0

0 0

wider beach 4260966.85 369586.44 64 8

27 69 13 60 0

0 0

0 0

same, then beach narrows 4260854.48 369643.59 65 21 68 63 25 105 0

0 0

0 0

same 4260744.83 369690.67 66 48 27 103 20 43 0

0 0

0 0

same, but wider beach 4260660.75 369735.11 67 12 8

126 3

24 0

0 0

0 0

10-20 m wide beach, Phrag. On back, no cliffs 4260545.77 369802.17 68 7

26 103 52 13 0

0 10 0

0 vehicle tracks on beach, dense Phragmites on back, and at 2 creeks(2nd creek) 4260411.18 369867.78 69=70 0

74 8

4 25 3

0 2

10 0

cliffs low, recessed, Phragmites on beach, wide beach, end at first creek 4260233.24 369964.10 71=72 5

10 14 8

5 20 0

39 12 2

cliffs fully vegetated, trees on back beach 4260112.20 370042.84

73 3

40 8

0 7

44 25 28 31 30 same but cliffs become heavily vegetated and lower 4259999.63 370105.24 74 0

5 0

0 0

120 26 18 22 135 beach narrows then widens, tree rubble, cliffs tall, most bare 4259891.53 370186.91 75 0

10 0

8 3

61 41 66 42 65 vegetated cliffs, become lower, v. wide beach (10-15 m), then narrows 4259813.51 370255.01 76 0

3 3

150 16 84 25 63 23 115 very tall, excellent cliffs, thick habitat band of soft sand; heavy shrubs at base 4259710.25 370353.16 77 18 138 14 240 70 150 47 88 35 95 wide beach,heavy Phragmites cover (60+%), heavy shrub cover at base of cliffs 4259618.35 370421.75 Subtotals for Western Shores 78 6

44 33 74 205 143 35 101 28 122 N end Calvert; lower cliffs, good beach, 10-12 m wide, end at creek entry 4259516.99 370518.71 79 29 98 32 3

8 100 5

150 17 315 continue good cliff habitat, then lower but good, end at large fallen tree 4259432.09 370593.61 80 2

23 25 1

0 100 16 247 11 260 excellent high cliffs with wide habitat band, 3-5 m wide beach 4259378.77 370644.76 81 2

36 3

0 0

16 32 68 1

96 start bare cliffs, soft ideal upper strata 4259341.01 370680.54 82 7

17 0

0 0

16 6

0 25 upper cliffs vegetated and recessed, lower part is marl, 2-4 m wide beach 4259297.40 370721.02 83 11 29 0

0 0

3 0

0 19 North most groin, then bare cliffs, narrow beach 4259252.57 370782.25 84 9

25 0

0 0

2 0

0 0

groin, cliffs fully vine covered, 5-7 m wide beach, new sand bags?

4259032.11 370983.60 85 0

0 0

0 0

0 Calvert Beach and WSE: Start at access, creek, start cliffs 4258960.66 371022.77 86 0

0 0

0 0

0 Calvert Beach South, cliffs, residential, groins 4258899.00 371078.00 87 0

0 0

0 0

0 cliffs, end of groins 4258760.00 371228.00 88 0

0 0

0 0

0 residential, end of cliffs, starts flat back-beach 4258650.00 371340.00 89 0

0 0

0 0

0 far south end, residential, at jetty, 4258458.00 371687.00 78 214 57 837 Subtotals for Calvert Beach 188 716 699 623 627 841 273 886 232 1279 Flag Ponds 90 1

2 6

8 0

0 0

0 0

North end, natural area,, avg 15ft back-beach to lagoon, beach narrow to gone 4257143.00 372756.00 91 3

1 1

0 0

0 0

0 0

natural area,, practically no back-beach 4256999.00 372920.00 92 2

2 30 17 0

0 0

0 0

natural area,, avg 5-10ft back-beach 4256918.00 373018.00 93 10 26 40 23 0

0 0

0 0

natural area,, avg 15-20ft back-beach 4256860.00 373094.00 94 13 23 18 15 0

0 0

0 0

natural area, avg 40-50ft back-beach 4256775.00 373164.00 95 9

0 0

0 0

0 0

0 0

start natural area; new accretion point 4256690.00 373168.00 96 5

6 3

3 0

0 0

0 0

no cliffs, avg 10-15ft back-beach to grass dunes 4256595.00 373050.00 97 8

1 23 14 0

0 0

0 0

no cliffs, avg 10-15ft back-beach to grass dunes 4256419.00 373057.00 98 0

0 0

0 0

0 0

0 pier 4256265.00 373114.00 99 0

0 0

0 0

0 0

0 south of pier to boundary fence 4256260.00 373137.00 51 61 121 80 0

0 0

0 0

Calvert Cliffs Nuclear Power Plant 100 0 No sur.

4 0

0 no 0

North beach, wide beach, avg 20ft back-beach, no cliffs 4256074.00 373233.00 101 0 in 2005 0

0 0 surv 0

same 4255928.00 373341.00 102 0

0 0

6 0

cliffs, avg 5ft back-beach 4255840.00 373426.00 103 0

0 0

0 0

cliffs, no back-beach 4255707.00 373559.00 104 0

0 0

3 0

same 4255538.00 373748.00 105 0

0 0

0 2

Start south of pier, main survey area, very rocky beach, no width, good cliffs 4254774.00 374636.00 106 0

0 0

6 6

0 same 4254697.00 374681.00 107 0

0 0

0 0

0 same 4254633.00 374786.00 108 0

0 8

2 7

6 same but wider beach 4254597.00 374818.00 109 0

0 10 43 13 44 wider sandy with shells beach (1-2 m) 4254527.00 374884.00 110 0

0 8

11 10 3

breakdown, rocky point, little habitat 4254412.00 374979.00 111 0

0 6

4 0

0 same, all very rock and no beach habitat 4254325.00 375085.00 112 0

0 4

0 0

0 same 4254288.00 375119.00 113 0

0 5

12 0

6 same but with sandy patches of beach; narrow some rocky, some sand 4254240.00 375146.00 114 0

0 11 36 6

18 arc beach, most sandy, 1-2 m 4254151.00 375163.00 115 0

0 24 23 36 28 same; rock, gravel, sand, medium width big breakdown just to south 4254053.00 375215.00 116 0

0 21 66 3

8 same 4253912.00 375341.00 117 0

0 4

28 0

0 point, rocky, no beach; very marginal, most beetles at S end 4253859.00 375397.00 118 0

0 21 45 19 6

start wide sandy beach, low cliffs 4253689.00 375475.00 119 0

0 0

end just to south, all hirticollis, no puritana habitat 4253617.00 375545.00 0

4 122 276 109 ns 121 Calvert Cliffs State Park 201 0

0 228 3

20 0

Farthest N that can be accessed, rocky shoreline, no beach, even at low tide 4252322 376584 N end of cliffs 6630 202 0

0 68 125 41 30 Here to north, very narrow, little beach habitat, but cliffs good 4251961 376687 wider beach sections and good cliffs 6794 start cliffs, no beach, inaccessible 6700 203 0

0 318 23 9

0 marsh and beach section, no habitat 4251855 376794 6858 204 0

0 264 87 168 110 tall cliffs, tree rubble, narrow beach, then 4-5 m wide beach with most beetles 4251711 376896 6906 beach narrows, little or no width 6968 205 0

0 97 0

28 70 trail accessing beach, very narrow beach, dry cliffs, then good top cliff area 4251569 376987 206 0

0 46 5

8 0

marsh area and beach, no cliffs, no habitat 4251447 377087 207 0

0 475 29 30 11 very narrow beach, excellent cliffs 4251334 377139 208 0

0 67 7

8 10 arc beach, 0-1 m wide beach, then 2-3 m wide 4251150 377244 209 0

0 46 13 26 11 mid, tall cliffs, good, 2-4 m wide beach, end at Rocky Point 4250975 377300 210 0

0 0

0 0

south end of site, cliffs no beach 0

0 1609 292 338 242 Cove Point 120 0

0 0

0 0

0 0

0 Cove Point: start at north end, N of pier where beach starts; 2-3 m marsh behind 4250383.35 377646.58 121 0

0 0

0 0

0 0

0 same 4250335.94 377706.05 122 0

0 0

0 0

0 0

0 pier 4250264.84 377783.59 123 0

0 0

0 0

0 0

0 0

narrow arc beach, with water behind 4250207.16 377810.49 124 0

0 0

0 0

0 0

0 0

dense Phragmites behind, coarse sand, narrow beach, 0-2 m 4250130.76 377907.96 125 0

0 0

0 0

0 0

0 0

GPS tube about 8 m offshore, phragmites on beach 4250072.66 377977.31 126 0

0 0

0 0

0 0

0 0

narrow beach 4250005.28 378036.22 127 0

0 0

3 0

0 0

0 0

beach wider, 1-2 m then widens to 5-7 m 4249958.70 378129.25 128 0

0 0

8 0

0 0

0 0

wide beach, 6-10 m wide; still Phragmites behind 4249915.53 378260.68 129 0

0 0

0 0

0 0

0 0

start first trees on back of beach; 8-12 m wide 4249879.53 378359.20 130 0

0 0

0 0

0 0

0 0

same, beach wider 4249822.44 378523.70 131 0

0 0

0 0

0 0

0 0

very wide beach, 20+ m 4249762.29 378699.79 132 0

0 0

0 0

0 0

0 0

same, intertidal sand is soft 4249721.56 378854.50 133 0

0 0

0 0

0 0

0 0

same 4249668.66 379073.50 134 0

0 0

0 0

0 0

0 0

end at north end of lighthouse 4249605.74 379242.64 0

11 0

0 Cove Point Hollow 135 0

0 no cliffs, residential cresent beach 4248963.00 378822.00 136 0

0 no cliffs, residential cresent beach 4248871.00 378750.00 137 0

0 no cliffs, residential cresent beach 4248652.00 378619.00 138 0

0 no cliffs, residential cresent beach 4248399.00 378519.00

139 0

0 vegetative cliffs, residential, 4248191.00 378473.00 0

0 Little Cove Point-July 6 140 0

0 0

32 0

0 0

8 cliffs, avg 20ft back-beach to cliffs, end open cliffs at this point 4247990.00 378548.00 141 0

0 0

47 14 21 8

14 cliffs, avg 4ft back-beach 4247932.00 378543.00 142=143 0

0 0

0 0

0 0

0 Cove Point Lake/Cove Lake, cliffs; beach end of cliffs 4247859.00 378548.00 144 0

0 0

0 0

0 0

0 start revetment 4247767.00 378578.00 145 0

0 0

60 25 0

0 0

end revetment 4247655.00 378624.00 146 0

0 0

99 29 22 0

11 Bannister point, arc beach 4247591.00 378668.00 147 0

0 0

161 13 40 0

3 same 4247522.00 378667.00 148 0

0 0

67 61 39 53 7

start point, then arc beach,low but good cliffs, breakdown area 4247387.00 378696.00 149 0

0 0

19 85 24 17 30 same, then high cliffs; good cliffs, wide beach; deck and stream entry 4247283.00 378706.00 150 0

0 0

17 3

2 4

0 no cliffs, then low cliffs; wood steps, terrace, rock revetment, set back 4247164.00 378755.00 151 0

0 0

8 43 11 5

0 point, then narrow arc beach, cliffs get lower 4247096.00 378822.00 152 0

0 0

73 52 0

0 0

another point section, then arc beach, no cliffs 4246977.00 378853.00 153 0

0 0

59 73 24 23 5

same, point; breakdown; 4th, N most pipe on back; breakdown; N end balls 4246798.00 378792.00 154 0

0 0

30 22 24 15 0

start point, no beach, good cliffs, break; drainage pipes on cliff sand bags 4246704.00 378742.00 155 0

0 0

3 15 26 4

16 same, medium cliffs, wide beach; stream channel and steps 4246584.00 378663.00 156 0

0 0

0 19 6

0 0

wider beach, low cliffs; hard cliffs 4246494.00 378601.00 157 0

0 0

77 27 11 6

2 same; massive breakdown 4246440.00 378572.00 158 0

0 0

21 5

90 9

4 same; breakdown, very high cliffs; massive breakdown 4246319.00 378518.00 159 0

0 0

46 23 33 22 6

mini-point, then recessed arc beach, narrow beach, good cliffs 4246233.00 378483.00 160 0

0 0

34 24 74 39 17 same,very high, good cliffs 4246147.00 378420.00 161 0

0 0

85 18 58 18 33 tree rubble but 1 m beach and good cliffs; breakdown 4246082.00 378376.00 162 0

0 0

8 29 36 15 22 same; N end of balls 4246018.00 378322.00 163 0

0 0

18 0

0 5

10 start good cliffs, 2 m beach, cliff terraced at top 4245951.00 378279.00 164 0

0 0

20 35 0

0 0

rock groin and rip rap (40 m long); S end of revetment 4245934.00 378254.00 165 0

0 0

6 0

0 4

8 start good cliff habitat; 1 m wide beach 4245870.00 378196.00 166 0

0 0

0 0

0 0

0 same 4245813.00 378153.00 167 0

0 0

0 0

0 0

0 wide beach, more groins; @ 12 total 4245723.00 378082.00 168 0

0 0

0 0

0 0

0 rock groins at south end of beach, then beach 4245646.00 378012.00 169 0

0 0

41 0

0 9

0 cliffs low, no habitat 4245561.00 377925.00 170 0

0 0

17 26 2

8 6

same, beach slightly wider 4245497.00 377878.00 171 0

0 0

53 14 40 14 13 eroded beach, tree rubble, but good cliffs; N end of balls 4245446.00 377834.00 172 0

0 0

15 85 32 20 36 S. end, start cliffs, 1-2 m beach, good cliff habitat 4245383.00 377774.00 0

0 0

1116 740 615 298 251 Cliffs of Calvert 173 0

0 0

0 6

0 0

0 N end, rock pile, then small pond, no habitat 4245303.00 377719.00 174 0

0 0

0 0

0 0

0 no habitat; breakdown and minipoint 4245157.00 377615.00 175 0

0 0

0 0

0 0

0 same; jus N of N end of balls 4245058.00 377552.00 176 0

0 0

9 9

0 0

0 start creek and marsh with no beach, no habitat 4244953.00 377484.00 177 0

0 0

0 3

21 4

6 start good cliff habitat 4244878.00 377427.00 178 0

0 0

7 26 15 2

0 same 4244838.00 377392.00 179 0

0 0

52 51 0

0 0

lower cliffs, then vegetated cliffs; S end of balls 4244759.00 377325.00 180 0

0 0

183 0

16 6

6 same 4244700.00 377281.00 181 0

0 0

31 34 8

0 18 wider beach, good cliff habitat 4244638.00 377236.00 182 0

0 0

154 20 24 11 3

continue good cliff habitat 4244609.00 377217.00 183 0

0 0

59 7

4 1

2 same 4244538.00 377166.00 184 0

0 0

175 14 13 1

5 same 4244504.00 377146.00 185 0

0 0

144 10 2

2 same 4244409.00 377075.00 186 0

0 0

13 0

0 0

0 same; 0-1 m wide beach 4244312.00 377018.00 187 0

0 0

2 2

0 3

0 good cliffs with no beach 4244241.00 376974.00 188 0

0 0

0 0

0 0

0 end rip rap, start good cliff habitat, no beach 4244162.00 376920.00 189 0

0 0

0 0

0 0

0 S. end, start N of beach at large house with rip 4244057.00 376863.00 0

0 829 172 111 30 42 Totals C. dorsalis 2007 2006 2005 2004 2006 2005 2004 Randle 0

0 0

0 18 31 27 C. Roosev.

0 0

0 ns 0

0 ns Bayside 0

0 0

0 6

2 0

Warrior 0

0 0

0 1388 155 na Sci.Cliffs 0

0 2

0 213 111 280 Wshore/Calv 716 699 623 627 886 232 1279 Flag 51 61 121 80 0

0 0

CCNPP 0

0 ns 4

109 ns 121 CCSP 0

0 0

0 338 242 ns Cove 0

0 0

11 0

0 0

Little Cove 0

0 0

0 615 298 251 Cliffs of Cal 0

0 0

0 111 30 42 767 760 746 722 3684 1101 2000