Ii7 Dominion-Dominion Nuclear Connecticut, Inc.
Millstone Power Station Rope Ferry Road Waterford, CT 06385 APR -. 4 2009 U.S. Nuclear Regulatory Commission Attention: Document Control Desk Director, Spent Fuel Project Office Office of Nuclear Material Safety and Safeguards Washington, DC 20555-0001 Serial No.09-248 MPS Lic/BAK RO Docket No.
72-47 50-336 License No.
DPR-65 DOMINION NUCLEAR CONNECTICUT, INC.
MILLSTONE POWER STATION UNIT 2 INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)
SUBMITTAL OF CASK REGISTRATION FOR SPENT FUEL STORAGE Pursuant to 10 CFR 72.212, "Conditions of general license issued under §72.210,"
paragraph (b)(1)(ii), Dominion Nuclear Connecticut, Inc. (DNC) hereby provides the Nuclear Regulatory Commission (NRC) notification regarding the registration of spent fuel storage casks approved under NRC Certificate of Compliance No. 1004. The required registration information is being submitted within 30 days of loading. The information required per 10 CFR 72.212(b)(1)(ii) follows:
Licensee Name:
Licensee Address:
Reactor License No.:
Reactor Docket No.:
Cask Certificate No.:
Cask Model No.:
Dominion Nuclear Connecticut, Inc.
Rope Ferry Road Waterford, CT 06385 DPR-65 50-336 1004 Standardized NUHOMS-32PT Canister Cask Identification Nos.: MPS32PT-S100-A-RO01 Initial Use: April 10, 2009 MPS32PT-S100-A-HZ010 Initial Use: April 17, 2009 MPS32PT-S100-A-HZ011 Initial Use: April 24, 2009 The above named casks are in use under Amendment 9 of Certificate of Compliance 1004.
In addition, pursuant to the General Requirements and Conditions of the Technical Specifications for Certificate of Compliance 1004, Amendment 9, Para. 1.1.7 "Special Requirements for First System in Place" a summary of the thermal performance of the highest heat load Standardized NUHOMS-32PT Dry Shielded Canister (DSC) placed in service at the Millstone Power Station ISFSI is provided.
MPS32PT-S100-A-R001 was loaded with Unit 2 spent fuel and stored in a NUHOMS Model 152 Horizontal Storage Module (HSM). The calculated thermal loading for this DSC is approximately 13.7 kW.
The inlet and outlet air temperatures for the HSM were measured consistent with the
Serial No.09-248 Submittal of Cask Registration For Spent Fuel Storage Page 2 of 2 method provided in Certificate No. 1004 Technical Specification 1.2.8. Upon obtaining equilibrium conditions, the measured inlet air temperature was 49 degrees F and measured outlet air temperature was 101 degrees F, corresponding to a temperature difference of 52 degrees F. This temperature difference is within the thermal performance temperature differential of 60 degrees F expected for a Model 152 HSM containing a DSC with a thermal loading of 13.7 kW at the given ambient conditions.
Should there be any questions regarding this submittal or additional information required regarding spent fuel storage under the general license requirements of 10 CFR 72 Subpart K, please contact Mr. Willam D. Bartron at (860) 444-4301.
Sincerely, A. J. 'J crdan Site Vice President - Millstone
Serial No.09-248 Submittal of Cask Registration For Spent Fuel Storage Page 3 of 3 Attachments:
None Commitments made in this letter: None cc:
U.S. Nuclear Regulatory Commission Region I Regional Administrator 475 Allendale Road King of Prussia, PA 19406-1415 Mr. J. J. Nicholson U. S. Nuclear Regulatory Commission - Region 1 475 Allendale Road King of Prussia, PA 19406-1415 Ms. C. J. Sanders NRC Project Manager U. S. Nuclear Regulatory Commission, Mail Stop 08B3 One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 NRC Senior Resident Inspector Millstone Power Station Mr. J. M. Goshen NRC Senior Project Manager - Millstone ISFSI U.S. Nuclear Regulatory Commission, Mail Stop EBB-3D-02M One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 Ms. J. A. Davis U.S. Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738