Post-quench Ductility Results for North Anna High-burnup 17x17 ZIRLO Cladding with Intermediate Hydrogen Content Y. Yan, T. A. Burtseva, and M. C. Billone Argonne National Laboratory April 17, 2009
- 1.
Pre-test characterization Figure 1 shows the axial locations of North Anna ZIRLO Rod AM2-L17 from which Studsvik sectioned and defueled 80-mm-long cladding segments for ANL. Segment axial orientation relative to the bottom of the fuel rod was not maintained during defueling. Characterization results for LOCA pre-test planning were generated for samples sectioned from segments labeled 1 and 2 in Fig. 1, which correspond to ANL identification numbers 648A and 648B, respectively.
Figure 2 shows micrographs at one of eight circumferential locations for: (a) cladding cross section; (b) corrosion layer; and (c) fuel-cladding bond. The measured thicknesses were 26+/-1 µm for the corrosion layer, 551+/-5 µm for the metal wall, and 7+/-1 µm for the fuel-cladding bond. However, as shown in Fig. 1c, local regions of the bond layer were about 20-25 µm thick. These thicker bond regions are consistent with the higher (factor of 2) gamma dose-rate readings for 648A and 648B, as compared to the dose rate reading for 648F (segment 6 in Fig. 1).
Figure 3 shows the hydride morphology at two circumferential locations adjacent to the sample with 318+/-30 wppm of hydrogen in the corroded cladding. As is typical of seven of the eight locations imaged, the hydrides are primarily circumferential and clustered in a dense rim near the corrosion layer, as is shown in Fig. 3a. Figure 3b shows one location that had long radial hydrides within the inner third of the cladding wall. For LOCA events, the radial variation in hydrogen content and hydride morphology are not important because hydrogen homogenizes quickly across the beta phase of the cladding.
Table 1 summarizes the characterization results for corrosion-layer thickness, cladding-metal thickness, fuel-cladding-bond layer thickness, and LECO-measured hydrogen content. For LECO measurements, short cladding rings (2-mm-long) were sectioned and then snipped into four quarter rings. The hydrogen content and mass were measured for each quarter ring. The hydrogen content included the hydrogen evolved from the cladding metal and the corrosion layer, as well as the bond layer.
The mass included the masses of the corrosion layer, the cladding metal, and the fuel-cladding bond. The four measurements per ring were also used to determine the one-sigma (1-) circumferential variation in hydrogen content. Based on the data listed in Table 1, the weight-averaged hydrogen contents of the two segments are 310+/-32 wppm for 648A and 366+/-30 wppm for 648B. Two LOCA oxidation samples were sectioned from 648A, and three LOCA oxidation samples were sectioned from 648B.
The pre-test hydrogen data were used for choosing target oxidation levels (i.e., CP-ECR values).
However, it was also realized that the hydrogen content in the cladding metal could be higher or lower than what was measured. As documented in Appendix A, LOCA samples were weighed before and after oxidation tests. Post-LOCA hydrogen contents were corrected for weight gain (1-2%). A final correction was made to take into account the ratio of the pre-test sample mass (measured) and metal mass (calculated from metallographic results). This factor (1.06 to 1.10) varied from sample to sample and reflected the added weight of the pre-test sample due to the fuel-cladding bond, which included fission products and actinides (heavier than Zr) in or adherent to the fuel-cladding bond. As shown in Table 1, the pre-test hydrogen in the metal is close to what was measured for the pre-test corroded samples.
2 Fig. 1. Sectioning diagram for North Anna ZIRLO defueled cladding segments sent to ANL from Studsvik in second shipment. Corresponding ANL ID numbers are 648A and 648B for segments 1 and 2, respectively (from Ref. 1).
3 (a) Cladding cross section (b) Corrosion layer (c) Fuel-cladding bond layer Fig. 2. Micrographs taken from a sample sectioned near the middle of segment 648A: (a) cladding cross section; (b) corrosion layer; and (c) fuel-cladding bond.
4 (a) Circumferential hydrides (b) Circumferential and radial hydrides Fig. 3. Hydride morphology for 648A sample with 318+/-30 wppm hydrogen: (a) circumferential hydrides (typical); and (b) circumferential and radial hydrides (one of eight locations).
5 Table 1.
North Anna ZIRLO Characterization Results for Rod AM2-L17 Sample ID #
W (ANL)
Corrosion Layer from Eddy Cur.
(EC), µm Corrosion Layer from Metallography,
µm Metal Layer from Metallography,
µm Fuel-Clad Bond Layer from Met.,
µm Hydrogen in Corroded
- Cladding, wppm Hydrogen in Cladding
- Metal, wppm 1
(648A) 25-28 26+/-1 551+/-5 7+/-1a 294+/-29 318+/-30 317+/-38 296+/-33 2
(648B) 25-30 361+/-36 367+/-29 370+/-33 340+/-34 aLocal regions of bond layer were as thick as 20-25 µm.
- 2.
Thermal and Metallurgical Benchmark Tests for Bare and Oxidized ZIRLO Thermal benchmark tests were conducted in the out-of-cell LOCA apparatus with two thermocouples (TCs) welded onto fresh (as-fabricated) ZIRLO samples, in addition to the three TCs permanently welded to the Inconel holder just above the sample. Tests were repeated with fresh samples until furnace control parameters were established to give the desired temperature ramp and hold temperature. The results of benchmark test ZLU#145 with a bare ZIRLO sample are shown in Fig. 4.
The time for the sample to reach 1200ºC was about 100 s. At 150 s, the average of the two sample TCs was 1202+/-7ºC. The heating phase of the test was 200 s. The corresponding CP weight gain and CP-ECR, including the cooling phase, were 8.27 mg/cm2 and 12.7%, respectively. The CP-calculated oxide layer grown on the inner and outer surfaces of the cladding was about 40-µm thick.
For high-burnup ZIRLO cladding, the corrosion and bond oxide layers will result in a slower ramp rate compared to the rate for bare ZIRLO. At the completion of benchmark test ZLU#145, the oxidized sample was again ramped to temperature using the same control parameters as were used for ZLU#145.
To distinguish these two tests, the one with the pre-oxidized sample was called ZLU#145A. Figure 5 shows the comparison between the average cladding temperatures for bare and pre-oxidized ZIRLO. The small temperature pre-peak was reduced from 1110ºC to 1060ºC. The average ramp rates to 1200ºC were comparable. However, the time to reach 1200ºC was longer for the pre-oxidized cladding (150 s vs.
100 s for bare cladding). The average temperature of the pre-oxidized cladding was 1200+/-3ºC at 150 s during the heating phase. It was later verified that there was essentially no difference in the thermal response of pre-oxidized cladding samples with thin (12 µm) and thick (40 µm) oxide layers. Thus, the ZL#145A thermal history was determined to be appropriate one for high-burnup cladding LOCA tests.
6 300 400 500 600 700 800 900 1000 1100 1200 1300 500 550 600 650 700 750 800 Time (s)
Temperature (°C)
Control TC1 on holder TC2 on holder TC3 on holder TC4 on sample TC5 on Sample Fig. 4. Thermal history for bare ZIRLO cladding determined from test ZLU#145. At 150 s into the heating phase, the average sample temperature was 1202+/-7ºC.
7 300 400 500 600 700 800 900 1000 1100 1200 1300 500 550 600 650 700 750 800 Time (s)
Temperature (ºC)
ZLU#145: bare ZIRLO ZLU#145A: pre-oxidized (40 µm) ZIRLO Fig. 5. Thermal history for bare ZIRLO (ZLU#145) and pre-oxidized (ZLU#145A) cladding. At 150 s into the heating phase, the average temperature for the pre-oxidized sample was 1200+/-3ºC.
8 The test train benchmarked in the out-of-cell LOCA apparatus, located just outside the hot cell, was installed into the in-cell apparatus located in Cell #4 of the Irradiated Materials Laboratory (IML) with the same three holder TCs welded onto the sample holder. A weight-gain benchmark test was conducted in-cell with bare ZIRLO. The same temperature history and heating-phase shown in Fig. 4 were used to conduct the weight-gain benchmark test ZLU#146. The measured weight gain (7.91 mg/cm2) was within 5% of the CP-calculated weight gain (8.27 mg/cm2). The CP-calculated weight gain was based on the ZLU#145 results. These results validate the use of the ZLU#145A thermal history for in-cell tests with corroded high-burnup ZIRLO samples.
- 3.
Ductility Results for High-burnup North Anna ZIRLO Four LOCA oxidation tests and 9 ring-compression ductility tests were conducted with samples sectioned from high-burnup ZIRLO segments 648A and 648B. Characterization results for these segments are given in Table 1. Post-oxidation and post-quench-ductility (PQD) data are summarized in Table 2.
For test planning purposes, the measured cladding wall thickness (0.55 mm) was used to derive the relationship between CP-ECR (in %) and Wg (in mg/cm2):
CP-ECR = 1.594 Wg (1)
Test ZLI#7 was conducted without quench with a sample containing about 340 wppm hydrogen in the cladding metal to ensure adequate ductility at 10% CP-ECR. The heating-phase test time (153 s) and corresponding CP-ECR (10%) are shown in Fig. 6 (see ZLU#145A history in Fig. 5). The pre-test sample outer diameter was 9.50 mm. Subtracting off the corrosion layer thickness measured at a neighboring location gave a pre-test cladding-metal outer diameter of about 9.45 mm. This pre-test metal diameter was used to normalize offset and permanent displacements to determine offset and permanent strains. As shown in Table 2, the offset and permanent strains at 135ºC were in the range of 10-13% and 5-9%, respectively. These results indicate significant ductility for the slow-cooled LOCA sample following oxidation to 10% CP-ECR. The results were used to plan the first test with quench.
For test ZLI#8, a lower hydrogen content (300 wppm) sample from 648A was used. The test time and CP-ECR were kept the same as were used for test ZLI#7. However, the sample was quenched at 800ºC. The effects of quench were significant in that the rings sectioned from the LOCA sample were brittle even though the sample had less hydrogen in the metal than the ZLI#7 sample. The offset strains were 0.7% (brittle) and 2.2% (borderline ductile), which imply brittle behavior based on the offset strain criterion documented in Ref. 2. Permanent displacements and strains could not be determined because the rings cracked into two pieces.
In order to bracket the ductile-to-brittle transition oxidation level, test ZLI#9, also with 300 wppm hydrogen, was conducted for a heating-phase time of 118 s, which corresponded to 8% CP-ECR.
As shown in Fig. 6, the peak oxidation temperature at the end of the heating phase was 1190ºC. The first two rings compressed at 135ºC also cracked at top and bottom locations with adequate offset strains of 2.9% and 4.6% indicative of ductile behavior. In order to confirm the ductile behavior, it was necessary to terminate the loading for the third ring before cracking occurred and after sufficient offset strain (2%).
Although there was a very low probability of achieving these goals, the test was successful in that the offset and permanent displacements of the uncracked ring were determined to be 0.19 mm and 0.11 mm, respectively. These correspond to 2.0% offset and 1.2% permanent strains (see Fig. B7 in Appendix B).
9 300 400 500 600 700 800 900 1000 1100 1200 1300 500 550 600 650 700 750 800 Time (s)
Temperature (ºC) 10%
CP-ECR 8%
CP-ECR Fig. 6. Thermal history and test times for high-burnup ZIRLO tests conducted to 8% (ZLI#9 and ZLI#11) and 10% (ZLI#7-8) CP-ECR.
10 Table 2.
Post-Test Ductility Results for High-Burnup North Anna ZIRLO Cladding Oxidized at 1200ºC, Cooled with or without (ZLI#7) Quench at 800ºC, and Ring-Compressed at 135ºC; SC= slow cooled without quench Pre-test Hydrogen Content, wppm
- Strain, Test #
Cladding Metala Test Time,b s
Peak Temperature,
ºC CP-ECR, Offsetc Permanent ZLI#7 SC 366+/-30 for 0.53-g sample 340+/-34 for 0.28-g sample 153 1200 10 9.9 13.4 5.0 9.4 ZLI#8 Quench at 800ºC 310+/-32 for 0.53-g sample 294+/-37 for 0.76-g sample 153 1200 10 0.7 2.2 ZLI#9 Quench at 800ºC 310+/-32 for 0.53-g sample 296+/-35 0.72-g sample 118 1190 8
2.9 4.6
>2.0
>1.2 ZLI#11 Quench at 800ºC 366+/-30 for 0.53-g sample 340+/-34 for 0.28-g sample 118 1190 8
0.6 1.0 aSee Appendix A for determination of pre-test hydrogen content in cladding metal.
bFrom beginning of ramp at 300ºC to end of heating phase.
cSee Appendix B for load-displacement curves.
11 Based on the results in Table 2 for tests ZLI#8 and ZLI#9, the ductile-to-brittle transition oxidation level is 9% CP-ECR for 300-wppm pre-test hydrogen content in the metal. Following this determination, the remaining two LOCA samples with 340-wppm pre-test hydrogen content in the metal were used for PQD tests. During the ZLI#10 ramp, the control thermocouple failed and the test was terminated after the other two thermocouples on the holder recorded temperatures above 1250ºC. The remaining sample was oxidized to 8% CP-ECR in test ZLI#11 and quenched at 800ºC. As indicated in Table 2, the two rings sectioned from this LOCA sample had very low offset strains (0.6-1.0%) indicating embrittlement.
Although the ductile-to-brittle transition CP-ECR could not be determined precisely, the data point is useful in establishing that the transition CP-ECR is < 8% for 340-wppm hydrogen.
- 4.
Discussion The embrittlement results for high-burnup 17x17 ZIRLO with 300-wppm pre-test hydrogen are consistent with the results presented in Ref. 1 for prehydrided (pre-H) 17x17 Zry-4. At 10% CP-ECR with quench at 800ºC, pre-H 17x17 Zry-4 had low ductility (2.8% offset strain) with 274-wppm hydrogen and was brittle with 335-wppm hydrogen. Although the ductile-to-brittle transition hydrogen content was given in Ref. 1 as 300+/-25 wppm for 10% CP-ECR, it is more likely that the transition occurs in the narrower range of 290+/-10 wppm. High-burnup ZIRLO with 300-wppm hydrogen had an embrittlement threshold of 9% CP-ECR. Based on the uncertainties in testing high-burnup cladding and the limited database for prehydrided cladding, results for both materials might overlap if multiple tests were conducted in the range of 8-10% CP-ECR for cladding with 300-wppm hydrogen. However, the prehydrided Zry-4 samples were subjected to faster temperature ramps and had slightly thicker cladding metal (0.57-mm) than the high-burnup samples (0.55 mm). Thus, for the same CP-ECR level, prehydrided Zry-4 samples were exposed to longer times at 1200ºC than high-burnup ZIRLO samples. A better comparison could be made if prehydrided ZIRLO with 300-wppm hydrogen were tested in the same test train with a similar temperature ramp rate as the one used for the high-burnup ZIRLO tests.
Also given in Ref. 1 are ductility data for prehydrided 17x17 Zry-4 and 15x15 Zry-4 oxidized to a heating-phase CP-ECR of 7.5% and quenched at 800ºC. The total CP-ECR for these samples, including the small weight gain during cooling, was 7.9% and 7.7%, which can be rounded off to 8%. For 17x17 Zry-4, the embrittlement hydrogen content was <400 wppm. For 15x15 Zry-4, the embrittlement hydrogen content was >360 wppm and <390 wppm. Although the embrittlement hydrogen content was given in Ref. 1 as 375+/-25 wppm, it is more likely that it occurs in the narrower range of 375+/-15 wppm.
Thus, the data point for high burnup ZIRLO with 340-wppm hydrogen was expected to be borderline ductile at 8% CP-ECR, especially as the peak oxidation temperature was slightly less than 1200ºC. It appears likely that high-burnup ZIRLO with 340-wppm would have been ductile at 7% CP-ECR.
The new results for PQD embrittlement threshold are compared to the ductility results presented in Ref. 1 for as-fabricated, prehydrided and high-burnup cladding materials. The ductility criteria used to determine the ductile-to-brittle threshold are those documented in Ref. 2: the highest CP-ECR rounded to the nearest percent for which the average permanent strain is 1% or the one-sigma (1-) lower-bound offset strain is 1.60 + 0.0534 CP-ECR (in %) if the permanent strain cannot be determined. Note that in Ref. 1 the one-sigma lower-bound permanent strain, not the average, was required to be 1%. Table 3 gives the recalculated results for as-fabricated cladding materials. Table 4 gives the results for prehydrided and high-burnup cladding materials. The last column, "Comments", in both tables indicates how the embrittlement thresholds were determined. The hydrogen contents for high-burnup ZIRLO and M5 have been corrected to reflect the pre-test hydrogen content in the metal (see Appendix A).
12 Table 3.
Embrittlement Oxidation Level for As-fabricated Cladding Alloys Oxidized at 1200ºC and Quenched at 800ºC; ductility criteria documented in Ref. 2 were used to determine ductile-to-brittle transition CP-ECR (to nearest percent): average permanent strain 1% or one-sigma lower-bound offset strain 1.60 + 0.0534 CP-ECR Pre-test Hydrogen Content, wppm
- Strain, Comment Material Cladding Metal Peak T,
ºC CP-ECR, Offset Permanent 17x17 M5 5
5 1200 20 3.5+/-0.5 1.0 Embrittlement threshold based on average permanent strain for 2 ring tests 15x15 Zry-4 26 26 1200 20 2.4+/-0.4 1.1+/-0.4 Embrittlement threshold based on average permanent strain for 2 ring tests 17x17 ZIRLO 5
5 1200 19 2.6+/-0.8 1.1+/-0.2 Embrittlement threshold based on average permanent strain for 2 ring tests 10x10 Zry-2 13 13 1200 20 1.7+/-0.3 1.0+/-0.1 Embrittlement threshold based on average permanent strain for 2 ring tests 17x17 Zry-4 5
5 1200 19 2.6+/-0.8 1.1+/-0.2 Embrittlement threshold based on average permanent strain for 2 ring tests 15x15 Zry-4 HBR-type 22 22 1200 16 2.9+/-0.5 1.1+/-0.3 Embrittlement threshold based on average permanent strain for 7 ring tests
13 Table 4.
Embrittlement Oxidation Level as a Function of Pre-test Hydrogen Content for Prehydrided and High-burnup Cladding Materials Oxidized at 1200ºC and Quenched at 800ºC; ductility criteria documented in Ref. 2 were used to determine ductile-to-brittle transition CP-ECR (to nearest percent): average permanent strain 1% or one-sigma lower-bound offset strain 1.60 + 0.0534 CP-ECR Pre-test Hydrogen Content, wppm Strain, %
Comment Material Cladding (mass)
Metal (mass)
Peak T,
ºC CP-ECR, Offset Permanent Ringhals High-burnup 17x17 M5 108+/-10 (0.40 g) 137+/-16 (1.56 g) 1200 15.1 13.4 2.8+/-0.7 4.2+/-0.2 (or 3.4+/-1.3)
Recommend 14+/-1% CP-ECR for embrittlement; see text on
- p. 14 for explanation 17x17 Zry-4 Prehydrided 290 290 1200 10 2.1%
Extrapolation of data for 209-and 274-wppm H rings gives 2.1% offset at 290 wppm NA High-burnup 17x17 ZIRLO 310+/-32 (0.53 g) 296+/-33 (1.44 g) 1200 1190 10 8
1.5+/-1.1 3.8+/-1.2
>1.2 Recommend 9% CP-ECR based on 1 ductile ring at 10% and 3 at 8%
HBR-type 15x15 Zry-4 Prehydrided 360 386 360 386 1200 1200 8
8 5.0 1.2+/-0.7 0.5+/-0.2 Interpolation gives 1-lower bound of 2.0% offset strain at 377 wppm, which is rounded down to 370 wppm HBR-type 15x15 Zry-4 Prehydrided 530 530 1190 5
2 Based on extrapolation of data for 460-520 wppm hydrogen samples HBR High-burnup 15x15 Zry-4 550+/-100 (1.52 g) 550+/-100 (1.52 g) 1180 5
Based on 37% offset stain for 4.5% CP-ECR sample cooled without quench NA High-burnup 17x17 ZIRLO 620+/-140 (0.55 g) 540+/-114 (0.26-g) 592+/-115 (0.27-g) 1176 1132 6.3 4.0 0.8+/-0.5
>43 0.2
>43 Based on interpolation, transition is at 5% CP-ECR for 540+/-114 wppm with 1162ºC peak cladding T
14 For as-fabricated (AF) cladding materials, determination of the ductile-to-brittle transition CP-ECR was straightforward as permanent displacements and strains were measured for the rings, which exhibited single, tight though-wall cracks. For prehydrided (PH) Zry-4, the tests were conducted at fixed oxidation levels with samples containing varying amounts of hydrogen. For early tests, samples had significant axial variation in hydrogen content (e.g., all 17x17 Zry-4 and some HBR-type 15x15 Zry-4). For later tests with HBR-type 15x15 Zry-4, the hydrogen content was relatively uniform. In determining the ductile-to-brittle hydrogen content for PF Zry-4 at 5% and 8% CP-ECR, data from samples with uniform hydrogen content were primarily used. However, reliance on the offset strain ductility criterion leads to added uncertainty in determining the embrittlement hydrogen content.
The data for high-burnup ZIRLO were relatively straightforward even though many of the rings failed with two cracks. However, by terminating one of the tests prior to failure, it was established at 8%
CP-ECR that 2.0% offset strain corresponded to 1.2% permanent strain. Although the embrittlement thresholds were determined using offset strains, there is a relatively high confidence in the offset strain ductility criterion for high-burnup ZIRLO at oxidation levels 10% CP-ECR. In addition, the rapid decrease in both offset and permanent strains in the range of 4-6% CP-ECR for high-burnup ZIRLO with 540-wppm hydrogen resulted in a straightforward interpolation of 5% CP-ECR embrittlement threshold.
The data for high-burnup M5 are important because of the low hydrogen content. These data were also the most difficult to assess because all of the rings from quenched LOCA samples failed with two cracks, rendering it impossible to measure permanent strain. Also, the decrease in offset strain with increasing CP-ECR was very gradual: 3.4+/-1.3% (or 4.2+/-0.02% for 2 of the 3 rings) at 13.4% CP-ECR, 2.8+/-0.7% at 15.1% CP-ECR, and 2.9+/-0.1.2% for 16.1% CP-ECR. The 1-lower-bound offset strains are: 2.1% (or 4.0% for 2 of the 3 rings), 2.1%, and 1.7%, for 13.4%, 15.1%, and 16.1% CP-ECR, respectively. The corresponding offset-strain ductility limits are: 2.3% at 13.4% CP-ECR, 2.4% at 15.1% CP-ECR and 2.5% at 16.1% CP-ECR. Using these limits would imply that high-burnup M5 would be brittle for 13.4% CP-ECR and perhaps ductile at 13% CP-ECR. However, excluding the one low ring-compression date point (1.9% offset strain) for the 13.4% CP-ECR sample would give a 1-lower-bound offset strain of 4.0% at 13.4% CP-ECR. Based on linear interpolation, the ductile-to-brittle transition CP-ECR would be 14.8%. Thus, within the uncertainty of the database and data assessment, the transition CP-ECR listed in Table 4 for high-burnup M5 is 14+/-1%.
The high-burnup M5 test samples for LOCA PQD tests at 15.1% CP-ECR (645C3) and 13.4% CP-ECR (645C6) were sectioned from an 80-mm-long segment (645C), which was wire-brushed to partially remove fuel-cladding bond material in order to reduce the gamma and beta-gamma dose rates of the material. Based on gamma dose-rate reduction after wire-brushing, it was clear that about half of the gamma-emitting isotopes (e.g., Ru-106, Sb-125, Cs-134, Cs-137, and Eu-154) were mechanically removed. Along with these isotopes, it is probable that actinides (alpha, beta, and gamma emitters) were also partially removed. Metallography was performed at a location between the two LOCA samples to confirm that the 8-µm fuel-cladding bond layer was intact. It exhibited a more uniform fuel-side surface indicating that the wire-brushing removed fingers and thinned local regions of increased bond thickness.
The embrittlement data contained in Tables 3 and 4 are summarized in Table 5 for ductile-to-brittle oxidation level vs. hydrogen content. Based on uncertainty and circumferential variation, average values listed in Table 5 are rounded to the nearest 10 wppm for hydrogen and 10ºC for temperature. Also included in Table 5 are high-burnup data for CP-ECR values that are greater or less than the embrittlement threshold. These were used as a guide in establishing the relationship between embrittlement threshold and hydrogen content. The data for embrittlement oxidation level vs. pre-test hydrogen content in the metal are plotted in Fig. 7.
15 Table 5 Summary of Ductile-to-brittle transition oxidation level (embrittlement CP-ECR) vs. pre-test hydrogen content in cladding metal for As-fabricated (AF), Prehydrided (PH) and High-burnup Cladding Materials; NA = North Anna and HBR = H. B. Robinson Cladding Material Pre-test Hydrogen Content in Cladding Metal, wppm Peak Oxidation Temperature,
ºC Embrittlement CP-ECR, %
AF 17x17 M5 5
1200 20 AF 15x15 Zry-4 26 1200 20 AF 17x17 ZIRLO 5
1200 19 AF 10x10 Zry-2 13 1200 20 AF 17x17 Zry-4 5
1200 19 AF HBR-type 15x15 Zry-4 (Old Vintage Cladding) 22 1200 16 Ringhals High-burnup 17x17 M5 140 1200 14+/-1 PH 17x17 Zry-4 290 1200 10 NA High-burnup 17x17 ZIRLO 300 1200 9
NA High-burnup 17x17 ZIRLO 340 1180
<8 PH HBR-type 15x15 Zry-4 370 1200 8
NA High-burnup 17x17 ZIRLO 450 1160
>5 PH HBR-type 15x15 Zry-4 530 1190 5
HBR High-burnup 15x15 Zry-4 550 1190 5
NA High-burnup 17x17 ZIRLO 540 1160 5
NA High-burnup 17x17 ZIRLO 590 1130
>4
16 0
2 4
6 8
10 12 14 16 18 20 0
100 200 300 400 500 600 700 800 Hydrogen Content (wppm)
Embrittlement CP-ECR (%) )
17x17 Zry-4 HBR-type (old) 15x15 Zry-4 17x17 ZIRLO 17x17 M5 15x15 Zry-4 10x10 Zry-2 Linear Fit for 400-wppm H Linear Fit for > 400-wppm H 63 GWd/t 70 GWd/t 70 GWd/t 64 GWd/t Fig. 7. Ductile-to-brittle transition oxidation level (CP-ECR) as a function of pre-test hydrogen content in cladding metal for as-fabricated (AF),
prehydrided (PF), and high-burnup cladding materials. Samples were oxidized at 1200ºC and quenched at 800ºC. For cladding materials with about 550-wppm hydrogen, embrittlement occurred for peak oxidation temperatures of 1160-1190ºC.
17 The data trend in Fig. 7 can be represented by a higher-order function or by a bi-linear function.
The bi-linear function shown in Fig. 7 was derived in the following way. Data points between 140 and 360 wppm were used to determine the line corresponding to 400-wppm hydrogen. Data points for high-burnup M5 and ZIRLO were assigned a weighting factor of two, while data for prehydrided Zry-4 were given a weighting factor of one. Although the data of <8% CP-ECR at 340-wppm hydrogen is not shown in Fig. 7, the embrittlement threshold at 340 wppm was assumed to be 7% and weighted with a factor of 2 to derive the linear fit. This is a more reasonable approach than to constrain the line to be below 8% at 340-wppm hydrogen, which would give this single point too much weight. A similar approach was used to fit the data at >400ºC: the high-burnup Zry-4 and ZIRLO data were assigned a weighting factor of two, while the prehydrided Zry-4 data point was assigned a weighting factor of 1. Also, a continuity constraint was imposed to ensure that the two linear fits agreed at 400-wppm hydrogen. The resulting equations are:
CP-ECR = 18.1 - 0.030 CH, for CH 400 wppm H (2) and CP-ECR = 6.1 - 0.0078 (CH - 400 wppm), for CH > 400 wppm H (3) where CH is the pre-test hydrogen content in the cladding metal (in wppm) and CP-ECR is the oxidation level (in %). At 340-wppm hydrogen, the embrittlement CP-ECR from Eq. 2 is 7.9%.
If very rapid heating rates (e.g., 10-20ºC/s) from 1000ºC to 1200ºC had been used in the experiments, it is probable that the shape of the embrittlement CP-ECR vs. hydrogen content would exhibit an increasing downward slope (convex shape). However, with the 2-3ºC/s ramp rates used in the Argonne tests, which are more reasonable upper bounds for LOCA, embrittlement for higher-hydrogen samples occurs during the ramp from 1000ºC to 1200ºC. Because of this decrease in temperature with increasing hydrogen content, the shape of the embrittlement curve shown in Fig. 7 exhibits a decreasing downward slope (convex shape) as hydrogen content increases. To minimize the effects of ramp rate on the embrittlement threshold, it is recommended that future tests with prehydrided cladding be conducted at 1000-1100ºC for hydrogen contents > 350 wppm for 17x17 cladding and > 500 wppm for thicker 15x15 cladding.
References
- 1. Michael Billone, Yong Yan, Tatiana Burtseva, and Robert Daum, "Cladding Embrittlement during Postulated Loss-of-Coolant Accidents," NUREG/CR-6967, July, 2008; available online in NRC ADAMS as ML082130389 at http://www.nrc.gov/NRC/reading-rm/adams.html.
- 2. "Procedure for Conducting Oxidation and Post-Quench Ductility Tests with Zirconium-based Cladding Alloys," Argonne National Laboratory, Mar. 31, 2009; available online in NRC ADAMS as ML090900841 at http://www.nrc.gov/NRC/reading-rm/adams.html.
18 Appendix A Determination of Hydrogen Content in Metal of Irradiated and Corroded Cladding The standard approach for determining the hydrogen content in irradiated cladding is to section a ring, weight the ring, heat the ring to melting, and measure the hydrogen evolved from the sample. For LOCA embrittlement, it is desirable to know the hydrogen content of the cladding metal. However, for the standard approach there are two sources of uncertainty, which have counter-balancing effects. The mass of the sample consists of the mass of the corrosion layer (MC), the mass of the cladding metal (MM) and the mass of the fuel-cladding bond (MB). For higher-burnup cladding, the mass of the bond layer can be significant if the defueling process is poor. The total hydrogen evolved from the sample consists of hydrogen mass in the corrosion layer (HC), in the cladding metal (HM) and in the cladding bond (HB). The bond layer can pick up hydrogen evolved from the nitric acid defueling process. Let LH (in wppm) be the total hydrogen (HS) evolved from the sample divided by the total mass of the sample (MS). Equation A1 represents what is generally reported for the hydrogen content of the cladding:
LH = (HS / MS) x 106 = (HC + HM + HB)/( MC + MM + MB) x 106 (A1)
Based on Eq. A1, the hydrogen content in the cladding metal may be greater or less than what is measured for the irradiated sample. There are two approaches that can be used to improve the reported values for cladding metal hydrogen content. For the first approach, the total hydrogen in the cladding metal can be determined by means of two stage heating. LECO markets a hydrogen analyzer (Model RH600) that can be programmed for the two stage heating. The first stage is the lower temperature stage during which hydrogen in the corrosion and bond oxide layers is driven off. The second stage is the heating-to-melting phase during which hydrogen in the metal is driven off. The lower temperature can be determined by varying it until the hydrogen evolved in the second-stage heating is a constant. The data can be represented by Eq. A2.
LHM = (HM / MS) x 106 = HM/( MC + MM + MB) x 106 (A2)
The second correction that needs to be made is to the cladding metal mass relative to the total sample mass. This can be made by measuring the total mass of a 25-mm-long sample to determine the sample mass per unit length (MS/L) and by measuring the sample outer diameter (standard profilometry),
the corrosion layer thickness (eddy current or metallography) and the cladding metal wall thickness (metallography). From the measurements, the cladding outer-and inner-diameter can be determined, as well as the cladding metal mass per unit length (MM/L). Let the metal mass correction factor be defined as fMM = (MS/L)/(MM/L). Applying this correction factor to LHM from Eq. 2 gives the hydrogen content in the cladding metal (CHM in wppm):
CHM = fMM x (HM / MS) x 106 (A3)
Based on Argonne experience, the metal mass correction factor is in the range of 1.06 to 1.10 for high-burnup ZIRLO with corrosion layer thicknesses of about 25-45 µm. The factors do not scale directly with the corrosion layer thickness because the mass of the fuel-cladding bond varies from defueled segment to defueled segment. For high-burnup M5 with a corrosion layer in the range of 10-15 µm, the factor can vary from 1.003 to 1.06, where the low value is for a segment whose inner-surface was wire brushed.
Given the magnitude of the cladding metal mass correction factor, it is not accurate to subtract the hydrogen content of the corrosion layer without accounting for the mass correction factor.
19 Argonne used a slightly different method for determining the hydrogen content in the cladding metal. The LECO machine was used to measure the pre-test hydrogen content of short rings adjacent to locations from which LOCA test samples were sectioned. These measurements give LHM as defined by Eq. A1. For most of the LOCA oxidation samples, the pre [(M)i]- and post [(M)POX]-test weights of the samples were measured, along with the pre-test length of the sample. Thus, the pre-test mass per unit length could be determined, along with the LOCA sample weight gain. LECO hydrogen measurements were performed after the LOCA oxidation and/or after ring-compression tests. Generally, the sample mass was larger than the pre-test sample mass. This was due to the higher availability of post-test material. The larger post-test mass increased the reliability of the data.
A two-step process was used to determine the pre-test hydrogen content in the cladding metal. The post-oxidation LECO hydrogen measurements [(LH)POX in wppm] were multiplied by the weight-gain factor [fWg = (M)POX/(M)i] to normalize the hydrogen content to the pre-test weight of the sample. The resulting hydrogen concentration was then multiplied by the same metal-mass correction factor (fMM) defined previously. The equation used to calculate the pre-test hydrogen content in the metal is:
CHM = fWg x fMM x (LH)POX (A4)
Table A1 summarizes the results for the pre-test hydrogen content in the metal calculated from the measured post-oxidation hydrogen content and compares them to the pre-test values measured for the corroded cladding. For high-burnup M5 cladding with a corrosion layer of 10-15 µm (12 µm measured by metallography at one location), the average hydrogen content in the metal was 20 wppm higher than the hydrogen content measured for the corroded pre-test sample. This difference is not very significant in that bare, as-fabricated cladding tested in the Argonne program picked up as much as 20 wppm of hydrogen during oxidation at 1200ºC. For high-burnup ZIRLO cladding with a corrosion layer of 25-30
µm (26 µm measured by metallography at one location), the average hydrogen content in the metal was 20 wppm less than the hydrogen content measured for the corroded pre-test sample. This difference is not significant relative to the circumferential and axial variations measured, as well as the differences in sample masses. For high-burnup ZIRLO cladding with a corrosion layer of 40-45 µm (41 and 43 µm measured by metallography at two locations), the average hydrogen content in the metal was 50 wppm less than the hydrogen content measured for the corroded pre-test sample. This difference may be significant. However, it is small relative to the circumferential and axial variations measured, as well as the effects of different sample masses for the two types of measurements.
For high-burnup H. B. Robinson (HBR) 15x15 Zry-4, pre-test hydrogen measurements at a location between LOCA oxidation samples, along with post-test hydrogen measurements were unreliable because the samples were samples were inadequately defueled. An additional segment was sectioned from an axial location adjacent to the LOCA oxidation samples, carefully defueled and sectioned into 8 rings for hydrogen determination. The hydrogen content (550+/-100 wppm) was relatively constant from ring to ring. Also, the total mass of the rings was 1.52 g. Thus, the 550+/-100 wppm of hydrogen measured is a very reliable characterization of the pre-test hydrogen content of the corroded cladding. The corrosion layer was 70-µm thick and the cladding metal wall was 710-µm thick. Including the bond layer, the metal-mass correction factor was calculated to be 1.09. However, the corrosion layer had about 10%
porosity and may have contained a significant amount of hydrogen. As no reliable post-oxidation hydrogen data are available are available for the HBR LOCA samples, it is assumed that the mass-correction factor and the corrosion-layer-hydrogen correction factor balance out to give 550+/-100 wppm of hydrogen in the cladding metal.
20 Table A1 Determination of Pre-test Cladding Metal Hydrogen Content based on Post-oxidation Hydrogen Measurements for High-burnup M5 and ZIRLO Samples used for LOCA Post-quench Ductility Determination; fWg = post-test-weight/pre-test-weight, fMM = pre-test sample-mass/metal-mass Material Test #
(ID#)
(LH)POX, wppm (mass) fWg Pre-test mass/L g/cm fMM Pre-test H in Clad.
Metal, wppm Pre-test H in Corroded Cladding, wppm (mass)
M5 MI#1 (645A1) 85+/-7 (0.35 g) 1.040 1.036 1.028 91+/-8 101+/-21 (0.1 g)
MI#2 (645A4) 107+/-14 (0.38 g) 1.040 1.042 1.035 115+/-15 101+/-21 (0.1 g)
MI#4 (645B6) 109+/-9 (0.26 g) 1.052 1.066 1.059 122+/-10 108+/-5 (0.22 g)
MI#5 (645B2) 130+/-11 (0.33 g) 1.047 1.039 1.033 140+/-12 108+/-5 (0.22 g)
MI#6 (645C3) 138+/-15 (0.25 g) 1.047 1.044 1.025 147+/-14 108+/-10 (0.40 g)
MI#7 (645C6) 130+/-15 (1.31 g) 1.039 1.007 1.003 135+/-15 108+/-10 (0.40 g)
ZIRLO ZLI#4 (648F2) 505+/-107 (0.26) 0.996 1.074 1.074 540+/-114 620+/-140 (0.55 g)
ZLI#5 (648F6) 505+/-107 (0.27) 0.99 1.074 1.096 592+/-115 600+/-150 (0.36 g)
ZLI#6 (648E2) 414+/-115 (0.79) 1.004 1.073 1.080 448+/-104 500+/-120 (0.24 g)
ZLI#7 (648B2) 316+/-31 (0.28) 1.011 1.068 1.062 340+/-34 366+/-30 (0.41 g)
ZLI#8 (648A3) 267+/-33 (0.76) 1.023 1.084 1.078 294+/-37 310+/-32 (0.53 g)
ZLI#9 (648A6) 274+/-33 (0.72) 1.017 1.067 1.061 296+/-35 310+/-32 (0.53 g)
21 Appendix B Load-displacement Curves for New Tests with High-burnup ZIRLO Samples with Pre-test Hydrogen Contents of 300-340 wppm in the Cladding Metal Figures B1-B9 show the load-displacement curves for rings sectioned from LOCA samples used in tests ZLI#7-9 and ZLI#11. Test conditions are listed on the graphs.
22 0
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0
0.5 1
1.5 2
2.5 Displacement (mm)
Load (kN) 0.94 mm 9.9% Offset Strain 5.0% Permanent Strain High-burnup ZIRLO Ring 648B2B from ZLI#7 Test Hydrogen Content in Metal = 340+/-34 wppm 10% CP-ECR, no Quench Ductile Fig. B1.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 10% CP-ECR and cooled without quench: Ring 648B2B.
23 0
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0
0.5 1
1.5 2
2.5 Displacement (mm)
Load (kN) 1.29 mm 13.7% Offset Strain 9.4% Permanent Strain High-burnup ZIRLO Ring 648B2D from ZLI#7 Test Pre-test hydrogen = 340+/-34 wppm 10% CP-ECR, no Quench Ductile Fig. B2.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 10% CP-ECR and cooled without quench: Ring 648B2D.
24 0
0.05 0.1 0.15 0.2 0.25 0.3 0
0.2 0.4 0.6 0.8 1
1.2 Displacement (mm)
Load (kN) 0.7% Offset Strain High-burnup ZIRLO Ring 648A3B from ZLI#8 Test Hydrogen Content in Metal = 300+/-33 wppm 10% CP-ECR, 800ºC Quench Brittle Fig. B3.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 10% CP-ECR and quenched at 800ºC: Ring 648A3B.
25 0
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0
0.2 0.4 0.6 0.8 1
1.2 Displacement (mm)
Load (kN) 0.21 mm 2.2% Offset Strain High-burnup ZIRLO Ring 648A3C from ZLI#8 Test Pre-test hydrogen = 300+/-33 wppm 10% CP-ECR, 800ºC Quench Low Ductility Fig. B4.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 10% CP-ECR and quenched at 800ºC: Ring 648A3C.
26 0
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5 0
0.2 0.4 0.6 0.8 1
1.2 1.4 Displacement (mm)
Load (kN) 0.27 mm 2.9% Offset Strain High-burnup ZIRLO Ring 648A6B from ZLI#9 Test Hydrogen Content in Metal = 300+/-33 wppm 8% CP-ECR, 800ºC Quench Ductile Fig. B5.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 8% CP-ECR and quenched at 800ºC: Ring 648A6B.
27 0
0.1 0.2 0.3 0.4 0.5 0.6 0
0.2 0.4 0.6 0.8 1
1.2 1.4 1.6 Displacement (mm)
Load (kN) 0.43 mm 4.6% Offset Strain High-burnup ZIRLO Ring 648A6C from ZLI#9 Test Pre-test hydrogen = 300+/-33 wppm 8% CP-ECR, 800ºC Quench Ductile Fig. B6.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 8% CP-ECR and quenched at 800ºC: Ring 648A6C.
28 0
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0
0.2 0.4 0.6 0.8 1
1.2 1.4 Displacement (mm)
Load (kN) 0.19 mm 2.0% Offset Strain (Loading Slope) 1.2% Offset Strain (Reloading Slope) 1.2% Permanent Strain Initial Loading Slope 0.59 kN/mm High-burnup ZIRLO Ring 648A6D from ZLI#9 Test Hydrogen Content in Metal = 300+/-33 wppm 8% CP-ECR, 800ºC Quench Load-Reload Test Ductile: >2.0% Offset Strain; >1.2% Permanent Strain Reloading Slope 0.52 kN/mm 0.11 mm Fig. B7.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 8% CP-ECR and quenched at 800ºC: Ring 648A6D.
29 0
0.05 0.1 0.15 0.2 0.25 0.3 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 Displacement (mm)
Load (kN) 0.6% Offset Strain High-burnup ZIRLO Ring 648B6B for ZLI#11 Test Hydrogen Content in Metal = 340+/-34 wppm 8% CP-ECR, 800ºC Quench Brittle Fig. B8.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 8% CP-ECR and quenched at 800ºC: Ring 648B6B.
30 0
0.05 0.1 0.15 0.2 0.25 0.3 0
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
1.1 Displacement (mm)
Load (kN) 1.0% Offset Strain High-burnup ZIRLO Ring 648B6C for ZLI#11 Test Hydrogen Content in Metal = 340+/-34 wppm 8% CP-ECR, 800ºC Quench Brittle Fig. B9.
Load-displacement curve for high-burnup ZIRLO cladding oxidized to 8% CP-ECR and quenched at 800ºC: Ring 648B6C.