Special Report (Spr) 2008-005-01 for Virgil C. Summer Inoperability of the Main Steam Line Radiation Monitor RM-G19C for Greater than 72 Hours
ML090930286
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 04/01/2009
From: Archie J
South Carolina Electric & Gas Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
SPR 2008-005-01
Download: ML090930286 (1)


Text

Jeffrey B. Archie Vice President, Nuclear Operations 803.345.4214 April 1, 2009 A SCANA COMPANY Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir/ Madam:

Subject:

VIRGIL C. SUMMER NUCLEAR STATION DOCKET NO. 50/395 OPERATING LICENSE NO. NPF-12 SPECIAL REPORT (SPR) 2008-005-01 South Carolina Electric & Gas Company (SCE&G) is submitting this revised report pursuant to the requirements of Technical Specification 3.3.3.1.b. This report addresses the inoperability of the Main Steam Line radiation monitor RM-G1 9C for greater than 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />.

During the inoperable period, V. C. Summer Nuclear Station (VCSNS) implemented a preplanned alternate method of monitoring in accordance with the requirements of Action 30 of the Technical Specification.

RM-G19C was declared inoperable September 2, 2008. On October 2, 2008, the Universal Digital Ratemeter (UDR) was replaced and RM-G1 9C was restored to operable status.

Subsequently, with vendor support, the communication board of the UDR was determined to be the specific cause of the UDR failure. The vendor believes the communication board failure was heat related and an isolated case related to a specific batch of communication boards. VCSNS has procured a spare communication board in case of future failure.

Should you have any questions, please call Mr. Bruce Thompson at (803) 931-5042 at your convenience.

Very truly yours, Jeffrey B. Archie JHW/JBA/cm c:

K. B. Marsh NRC Resident Inspector S. A. Byrne K. M. Sutton N. S. Carns INPO Records Center J. H. Hamilton NSRC R. J. White RTS (CR-08-03805)

K. J. Browne File (818.08)

L. A. Reyes PRSF (RC-09-0038)

R. E. Martin SCE&G I Virgil C. Summer Nuclear Station - P. O. Box 88 *Jenkinsville, South Carolina 29065