ML090680572
| ML090680572 | |
| Person / Time | |
|---|---|
| Site: | Nuclear Energy Institute |
| Issue date: | 12/10/2009 |
| From: | Rosenberg S NRC/NRR/DPR/PSPB |
| To: | Bradley B Nuclear Energy Institute |
| Mensah T | |
| References | |
| TAC MD5134 | |
| Download: ML090680572 (3) | |
Text
December 10, 2009 Mr. Biff Bradley, Director Risk Assessment Nuclear Energy Institute Suite 400 1776 I Street, NW Washington, DC 20006-3708
SUBJECT:
DRAFT SAFETY EVALUATION FOR NUCLEAR ENERGY INSTITUTE TOPICAL REPORT WCAP-16294-NP, REVISION 0, RISK-INFORMED EVALUATION OF CHANGES TO TECHNICAL SPECIFICATION REQUIRED ENDSTATES FOR WESTINGHOUSE NSSS [NUCLEAR STEAM SUPPLY SYSTEM] PWRs
[PRESSURIZED WATER REACTORS], AUGUST 2005 (TAC NO. MD5134)
Dear Mr. Bradley:
By letter dated September 9, 2005, as supplemented by letters dated December 12, 2007 and November 26, 2008, Nuclear Energy Institute (NEI) submitted Topical Report (TR) WCAP-16294-NP, Revision 0, Risk-Informed Evaluation Of Changes To Technical Specification Required Endstates For Westinghouse NSSS PWRs, to the U.S. Nuclear Regulatory Commission (NRC) staff for review. Enclosed for NEI review and comment is a copy of the NRC staff's draft safety evaluation (SE) for the TR.
Twenty working days are provided to you to comment on any factual errors or clarity concerns contained in the SE. The final SE will be issued after making any necessary changes and will be made publicly available. The NRC staff's disposition of your comments on the draft SE will be discussed in the final SE.
To facilitate the NRC staff's review of your comments, please provide a marked-up copy of the draft SE showing proposed changes and provide a summary table of the proposed changes.
If you have any questions, please contact Tanya Mensah at 301-415-3610.
Sincerely,
/RA/
Stacey L. Rosenberg, Chief Special Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project No.: 689
Enclosure:
Draft SE cc w/encl: See next page
If you have any questions, please contact Tanya Mensah at 301-415-3610.
Sincerely,
/RA/
Stacey L. Rosenberg, Chief Special Projects Branch Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Project No.: 689
Enclosure:
Draft SE cc w/encl: See next page DISTRIBUTION:
PUBLIC PSPB Reading File RidsNrrDpr RidsNrrDprPspb RidsNrrPMTMensah RidsNrrLADBaxley RidsOgcMailCenter RidsAcrsAcnwMailCenter RidsNrrDss RidsNrrDra RidsNrrDraApla RidsNrrDssSrxb RidsNrrDssScvb RidsNrrDssSpbc RidsNrrDirs/Tsb RisNrrDirp/Rib RidsNrrDe SRosenberg (HardCopy)
ADAMS ACCESSION NO.:
- No major changes to SE input.
NRR-043 (ML090680648) Package; (ML090680572) Cover Memo; (ML090680580) Enclosure OFFICE PSPB/PM PSPB/LA DRA/APLA DSS/SRXB*
DSS/SCVB*
DSS/SBPB NAME TMensah DBaxley (GLappert For)
MRubin GCranston RDenning MWaters (Acting)
GPurciarello for DATE 03/30 /09 04/18/09 04/11/08 03/18/08 03/18/08 05/ 14 /09 OFFICE DIRS/IRIB DSS/SNPB DE/EEEB DIRS/ITSB DPR/PSPB NAME TKobetz JIsom for AMendiola GWilson (w/comment)
RElliott MHamm for SRosenberg DATE 05/ 19 /09 08/ 31 /09 05/20 /09 12/01/09 12/10/09
B. Bradley 3
Nuclear Energy Institute Project No. 689 cc:
Mr. Anthony Pietrangelo, Senior Vice President & Chief Nuclear Officer Nuclear Generation Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 arp@nei.org Mr. Jack Roe, Director Security Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 jwr@nei.org Mr. Charles B. Brinkman Washington Operations ABB-Combustion Engineering, Inc.
12300 Twinbrook Parkway, Suite 330 Rockville, MD 20852 brinkmcb@westinghouse.com Mr. James Gresham, Manager Regulatory Compliance and Plant Licensing Westinghouse Electric Company P.O. Box 355 Pittsburgh, PA 15230-0355 greshaja@westinghouse.com Ms. Barbara Lewis Assistant Editor Platts, Principal Editorial Office 1200 G St., N.W., Suite 1100 Washington, DC 20005 Barbara_lewis@platts.com Mr. Alexander Marion, Vice President Nuclear Operations Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 am@nei.org Mr. John Butler, Director Operations Support Nuclear Energy Institute 1776 I Street, NW, Suite 400 Washington, DC 20006-3708 jcb@nei.org Dennis Buschbaum PWROG Chairman Comanche Peak Steam Electric Station 6322 North Farm to Marked Rd 56 Mail Code E15 Glen Rose, TX 76043 Dennis.Buschbaum@luminant.com