March 23, 2009 Dr. Kenan Unlu, Director Radiation Science and Engineering Center (RSEC)

Breazeale Nuclear Reactor University Park, PA 16802-2301

SUBJECT:

PENNSYLVANIA STATE UNIVERSITY - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE PENN STATE BREAZEALE REACTOR EMERGENCY PLAN SUBMITTED WITH THE APPLICATION FOR LICENSE RENEWAL (TAC NO. MC9534)

Dear Dr. Unlu:

The U.S. Nuclear Regulatory Commission (NRC) is continuing the review of your application for renewal of Facility Operating License No. R-2 for the Pennsylvania State University Penn State Breazeale Reactor dated December 6, 2005, as supplemented by letter dated October 31, 2008. During NRC staff review it was determined that additional information and clarification contained in the enclosure is required to continue the review. Please provide a response to the enclosed request for additional information no later than April 10, 2009. In accordance with Title 10 of the Code of Federal Regulations Part 50.30(b), your response must be executed in a signed original under oath or affirmation.

If you have any questions regarding this review, please contact me at 301-415-2784 or by electronic mail at William.Kennedy@nrc.gov.

Sincerely,

/RA/

William B. Kennedy, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.: 50-005

Enclosure:

As stated cc w/enclosure: See next page

Pennsylvania State University Docket No.: 50-005 cc:

Mr. Eric J. Boeldt, Manager of Radiation Protection The Pennsylvania State University 304 Old Main University Park, PA 16802-1504 Dr. Eva J. Pell Vice President and Dean of the Graduate School Pennsylvania State University 304 Old Main University Park, PA 16802-1504 Director, Bureau of Radiation Protection Department of Environmental Protection P.O. Box 8469 Harrisburg, PA 17105-8469 Test, Research, and Training Reactor Newsletter University of Florida 202 Nuclear Sciences Center Gainesville, FL 32611

OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR ADDITIONAL INFORMATION PENNSYLVANIA STATE UNIVERSITY PENN STATE BREAZEALE REACTOR DOCKET NO.50-005 The U.S. Nuclear Regulatory Commission (NRC) is continuing the review of your application for renewal of Facility Operating License No. R-2 for the Pennsylvania State University Penn State Breazeale Reactor (PSBR) dated December 6, 2005, as supplemented by letter dated October 31, 2008. The following requests for additional information are based on a comparison of the PSBR emergency plan, dated September 21, 2000 vs. American National Standard ANSI/ANS-15.16, Emergency Planning for Research Reactors, dated May 2000, and NUREG-0849, Standard Review Plan for the Review and Evaluation of Emergency Plans for Research and Test Reactors, dated October 1983.

1.

Please provide the frequency for updating the written agreements with the primary fire-fighting agency (Section 3.1.6) and medical facility provider (Section 3.1.9) and indicate whether updating these agreements is governed by a PSBR procedure. Provide a current copy of each of these agreements.

2.

Do PSBR procedures require notification of the NRC in approximately one hour for emergency class declarations? If not, review NRC Information Notice 92-79, Non-power Reactor Emergency Event Response, and revise accordingly.

3.

Please provide a copy of the NRC Operations Center notification form discussed in Section 7.1.

4.

Describe any sources of meteorological data representative of the PSBR site that would be used during an emergency that warrants use of such data. Are any meteorological data sources indicated in the PSBR procedures?

5.

What type of initial and periodic retraining is offered to emergency response support personnel, i.e., first aid responders, fire fighters, and medical personnel? Please discuss PSBR procedural requirements that govern this training.

March 23, 2009 Dr. Kenan Unlu, Director Radiation Science and Engineering Center (RSEC)

Breazeale Nuclear Reactor University Park, PA 16802-2301

SUBJECT:

PENNSYLVANIA STATE UNIVERSITY - REQUEST FOR ADDITIONAL INFORMATION REGARDING THE PENN STATE BREAZEALE REACTOR EMERGENCY PLAN SUBMITTED WITH THE APPLICATION FOR LICENSE RENEWAL (TAC NO. MC9534)

Dear Dr. Unlu:

The U.S. Nuclear Regulatory Commission (NRC) is continuing the review of your application for renewal of Facility Operating License No. R-2 for the Pennsylvania State University Penn State Breazeale Reactor dated December 6, 2005, as supplemented by letter dated October 31, 2008. During NRC staff review it was determined that additional information and clarification contained in the enclosure is required to continue the review. Please provide a response to the enclosed request for additional information no later than April 10, 2009. In accordance with Title 10 of the Code of Federal Regulations Part 50.30(b), your response must be executed in a signed original under oath or affirmation.

If you have any questions regarding this review, please contact me at 301-415-2784 or by electronic mail at William.Kennedy@nrc.gov.

Sincerely,

/RA/

William B. Kennedy, Project Manager Research and Test Reactors Branch A Division of Policy and Rulemaking Office of Nuclear Reactor Regulation Docket No.: 50-005