HISTORIC STRONTIUM TRITIUM RESULTS WELL WATER I SOIL 0
RIVER WATER DRINKING WATER HR SHELLFISH HR FISH AIR PARTICULATES LAKE WATER YEAR H3 Sr89 Sr90 Sr89 Sr90 H3 Sr90 (pCI/m3)
H3 Sr90 H3 Sr90 1974 950 30 72 27 3.5 474 4.60E-04 484 0.8 328 340
.1975 615 170 27 333 7.50E-04 400 300 250 1976 513 30 254 6.60E-04 326 346 170 1977 290 1
11 4.4 193 7.00E-04 200 2.2 320 150 1978 630 140 8.9 208 2.10E-03 253 236 78 1979 354 7
0.42 170 3.90E-03 244 195 140 1980 358 13 11 267 4.50E-03 190 242 140 1981 300 90 20 240 2.OOE-03 240 0.6 380 72 1982 370 40 121 13.7 190 3.OOE-04 210 1
290 84 1983 540 11 7
122 9.OOE-04 146 213 195 1984 541 8.4 33.7 178 174 232 740 pCi/L pCi/kg - wet pCi/kg - wet pCi/L pCi/m3 pCi/L pCi/L pCi/L pCi/Kg - dry Note: July 1984 switched from ETSR to RETS, which eliminated requirements for Strontium analyses, Lake Water and Well Water