Tennessee Valley Authority, Post Office Box 2000, Soddy Daisy, Tennessee 37384-2000 February 17, 2009 State of Tennessee Department of Environment and Conservation Division of Water Pollution Control Enforcement & Compliance Section 6 lh Floor, L & C Annex 401 Church Street Nashville, Tennessee 37243-1534

Dear Mr. Patrick Cromer:

SEQUOYAH NUCLEAR PLANT (SQN) - NPDES PERMIT NO. TN0026450 -

CORRECTION TO DISCHARGE MONITORING REPORT FOR DECEMBER 2008 During the review of the Biocide/Corrosion Treatment Plan (B/CTP) it was noted that three total residual chloride analyses had been omitted from the December 2008 Discharge Monitoring Report (DMR). Please see the attached corrected DMR page.. It should be noted that the chlorine, total residual maximum value remained the same at 0.032mg/L and the chlorine, total residual average value increased from 0.01 7mg/L to 0.018 mg/L.

Please contact me at (423) 843-6700 or by emailat sahoward@tva.gov if you have any questions or need additional information.

Sincerely, Stephanie A. Howard Principal Environmental Engineer Signatory Authority for Timothy P. Cleary Site Vice President Sequoyah Nuclear Plant

A,

  • J Enclosure cc (Enclosure):

Chattanooga Environmental Field Office Division of Water PoIlLition Control State Office Building, Suite 550 540 McCallie Avenue Chattanooga, Tennessee 37402-2013 U.S. Nuclear Regulatory Commission ATTN:.Document Control Desk Washington, D.C. 20555

PERMITTEE NAME/ADDRESS (Include Facilitv Name/Location if Different)

Name "TVA - SEQUOYAH NUCLEAR PLANT Address P.O. BOX 2000

-(INTEROFFICE SB-2A SODDY - DAISY TN 37384 Facility TVA - SEQUOYAH NUCLEAR PLANT Location HAMILTON COUNTY ATTN: Stephanie A. Howard NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES)

MAJOR DISCHARGE MONITORING REPORT (DMR)

(SUBR 01)

TN0026450 101 G F -FINAL PERMIT NUMBER DISCHARGE NUMBER DIFFUSER DISCHARGE MONIT RING PERIOD EFFLUENT Form Approved, OMB No. 2040-0004 YEAR MO I YEAR MO DAY NO DISCHARGE From 08 12 011 To 08 12 31 INU R

_. teao ilst[ructions before cjUIplein[

thisl lor.

PARAMETER QUANTITY OR LOADING QUALITY OR CONCENTRATION NO.

EX FREQUENCY SAMPLE OF TYPE ANALYSIS AVERAGE MAXIMUM*

UNITS MINIMUM AVERAGE MAXIMUM UNITS CHLORINE, TOTAL RESIDUAL SAMPLE 1 0018 0.032 19 0

21/31 GRAB PEMM 0.1

§0.1032 M.19E 50060 1

0 0

REQRENT PERMIT MGIL

.:10EEK.,CALCTD EFFLUENT GROSS VALUE MOOURMET AVG INST MAX DAYS--

SAPL 31 / 31 CALCTD!

TEMPERATURE - C, RATE OF SAMPLE 1

62 0

CHANGE MEASUREMENT 82234 1

0 0

~

PERMITi 2

DEG CNTIN' CALCTD EFFLUENT GROSS VALUE REQUIREMENT?

DAILY C/HR UOUS SAMPLE MEASUREMENT

>REQUIREMENT

- SAMPLE MEASUREMENT

~REQUIR EMENT 1.-rA SAMPLE MEASUREMENT PERMIT REQUIREMENT SAMPLE MEASUREMENT PERMIT.

R~EOUIREMENT

<_______j SAMPLE MEASUREMENT PERMIT?~

~REQUIlREMENT NAME/TITLE PRINCIPAL EXECUTIVE OFFICER I lirection or Timothy P. Cleary Site Vice President der penalty of law that this document and all attachments were prepared under my supervision in accordance with a system designed to assure that qualified personnel her and evaluate the information submitted. Based on my inquiry of the person or o manage the system, or those persons directly responsible for gathering the the information submitted is, to the best of my knowledge and belief, true, nd complete. I am aware that there are significant penalties for submitting false including the possibility of fine and imprisonment for knowing violations.

Principal Environmental Engineer SIGNATURE OF PRINCIPAL EXECUTIVE OFFICER OR AUTHORIZED AGENT information, TYPED OR PRINTED COMMENTS AND EXPLANATION OF ANY VIOLATIONS (Reference all attachments here)

The following injections occurred: 1. Biodetergent 73551 (max. calc. conc. was 0.017mg/L--limit 2.Omg/L)

EPA Form 3320-1 (REV 3199)

Previous editions may be used Page 2 of 2