ML090430427

From kanterella
Jump to navigation Jump to search
NPDES Discharge Monitoring Report for December 2008
ML090430427
Person / Time
Site: Perry  
Issue date: 01/14/2009
From: Bezilla M
FirstEnergy Nuclear Operating Co
To:
Office of Nuclear Reactor Regulation, State of OH, Environmental Protection Agency
References
PY-CEI/OEPA-0499L
Download: ML090430427 (9)


Text

FENOC Perry Nuclear Power Station 10 Center Road FirstEnergy Nuclear Operating Company Perry, Ohio 44081 Mark B. Bezilla 440-280-5382 Vice President

.Fax 440-280-8029 January 14, 2009 PY-CEI/OEPA-0499L Ohio Environmental Protection Agency Division of Water Pollution Control Enforcement Section, ES/DMR P.O. Box 1049 Columbus, Ohio 43216-1049

SUBJECT:

Perry Nuclear Power Plant, December NPDES Discharge Monitoring Report Enclosed are the Perry Nuclear Power Plant, NPDES monthly report forms for the month of December 2008. No violations occurred during this period.

If you have questions or require additional information, please contact Mr. Randall Killing at (440) 280-7370.

Sincerely, Mark B. Bezilla

Enclosures:

A Station Code 004 Report B Station Code 094 Report C Station Code 601 Report D Station Code 602 Report E Station Code 800 Report cc: NRC Region III NRC Resident Inspector NRR Project-Manager NRC Document Control Desk (Docket No. 50-440)

Page 1 MR.'

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:

LOCATION:

COUNTY:

DISTRICT:

FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:

STATION CODE:

MONITORING PERIOD:

REPORTING LAB:

ANALYST:

NO DISCHARGE INDICATOR:

3IB00016*ID 004 2008-12-01 To: 2008-12-31 CCB 125 PSKowaslki Water Zinc, Total Copper, Total Oxidants, Total Chlorine, Total Temperature Recoverable Recoverable Residual Residual PARAMETER CODE 00011 50050 00400 01094 01119 34044 50060 UNITS 4103 4108 6653 4107 4107 4106 4106 FREQUENCY 1/Day I/Day 2/Week I/Month I/Month When Disch.

When Disch.

SAMPLING TYPE Continuous Continuous Grab Grab Grab Grab Grab 2008-12-01 49 57.0 AH AA 0.05 2008-12-02 49 54.4 8.34 AH AA 0.05 2008-12-03 47 57.6 AH AA 0.05 2008-12-04 49 42.7 AH AA 0.05 2008-12-05 50 44.3 8.62 AH AA 0.05 2008-12-06 48 45.5 AN AA 0.05 2008-12-07 50 44.6 AH AA 0.05 2008-12-08 46 45.7 12 6

AH AA 0.05 2008-12-09 49 39.3 8.65 AlI AA 0.05 2008-12-10 52 43.3 AH AA 0.05 2008-12-11 49 43.0 AH AA 0.05 2008-12-12 49 39.2 8.3 AH AA 0.05 2008-12-13 48 45.9 AH AA 0.05 2008-12-14 50 40.0 AN AA 0.05 2008-12-15 52 50.0 AH AA 0.05 2008-12-16 47 62.6 8.43 AN AA 0.05 2008-12-17 46 60.9 AH 0.07 2008-12-18 46 61.8 AH AA 0.05 2008-12-19 45 61.5 8.28 AH AA 0.05 2008-12-20 45 58.9 AH AA 0.05 2008-12-21 45 59.6 AH AA 0.05 2008-12-22 44 64.5 AN AA 0.05 2008-12-23 42 64.9 8.13 AH AA 0.05 2008-12-24 43 52.7 AH AA 0.05 2008-12-25 46 54.8 AH AA 0.05 2008-12-26 43 51.6 8.2 AN AA 0.05 2008-12-27 48 54.8 AH AA 0.05 2008-12-28 51 51.8 AH AA 0.05 2008-12-29 48 51.0 AH AA0.05 2008-12-30 49 50.5 8.18 AH AA 0.05 2008-12-31 47 53.6 AH AA 0.05 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of I Date (M1VI/DD/YY)

Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or, Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative Vp 1( odff i significant penalties for submitting false information, including the possibility of V

fine and imprisonment.

h L7 When completed mail this report to: EDMR Administrator, EDMR Administrator,,, OH,

/Z Page I httpsH//ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f...

1/7/2009

Page2of t@

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:

LOCATION:

COUNTY:

DISTRICT:

FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:

STATION CODE:

MONITORING PERIOD:

REPORTING LAB:

ANALYST:

NO DISCHARGE INDICATOR:

3IB000166*ID 004 2008-12-01 To: 2008-12-31 CCB 125 PSKowaslki Chlorination/Brominatior PARAMETER Duration PARAMETER 78739 CODE UNITS 6655 FREQUENCY When Disch.

SAMPLING TYPE Total 2008-12-01 41 2008-12-02 44 2008-12-03 40 2008-12-04 40 2008-12-05 40 2008-12-06 40 2008-12-07 40 2008-12-08 35 2008-12-09 40 2008-12-10 35 2008-12-11 41 2008-12-12 40 2008412-13 40 2008-12-14 50 2008-12-15 35 2008-12-16 40 2008-12-17 35 2008-12-18 35 2008-12-19 70 2008-12-20 57 2008-12-21 35 2008-12-22 32 2008-12-23 10 2008-12-24 10 2008-12-25 20 2008-12-26 10 2008-12-27 19 2008-12-28 15 2008-12-29 40 2008-12-30 10 2008-12-3 1 40 H

Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DD/YY)

Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility ofn/

V P i~ '1 fine and imprisonment.

/,A 2Z When completed mail this report to: EDMR Administrator, EDMR Administrator,,, OH, Page

/

https://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType~viewWithXslt&f...

1/7/2009

Page 4 of f 0 Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:

LOCATION:

COUNTY:

DISTRICT:

FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:

3IB00016*ID STATION CODE:

094 MONITORING PERIOD:

2008-12-01 To: 2008-12-31 REPORTING LAB:

CCB 125 ANALYST:

PSKowalski NO DISCHARGE INDICATOR:

AL Water Zinc, Total Copper, Total Oxidants, Total Chlorine, Total Temperature Recoverable Recoverable Residual Residual PARAMETER CODE 00011 50050 00400 01094 01119 34044 50060 UNITS 4103 4108 6653 4107 4107 4106 4106 FREQUENCY I/Day I/Day 2/Week 1/Month I/Month When Disch.

When Disch.

SAMPLING TYPE Continuous Continuous Grab Grab Grab Grab Grab 2008-12-01 2008-12-02 2008-12-03 2008-12-04 2008-12-05 2008-12-06 2008-12-07 2008-12-08 2008-12-09 2008-12-10 2008-12-11 2008-12-12 2008-12-13 2008-12-14 2008-12-15 2008-12-16 2008-12-17 2008-12-18 2008-12-19 2008-12-20 2008-12-21 2008-12-22 2008-12-23 2008-12-24 2008-12-25 2008-12-26 2008-12-27 2008-12-28 2008-12-29 2008-12-30 2008-12-31 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DD/YY)

Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility ofar ni N P t) &2U fine and imprisonment.

4 o

When completed mail this report to: EDMR Administrator, EDMR Administrator, _ OH, Page A https://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f...

1/7/2009

Page 5 of-f8 Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:

LOCATION:

COUNTY:

DISTRICT:

FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:

STATION CODE:

MONITORING PERIOD:

REPORTING LAB:

ANALYST:

NO DISCHARGE INDICATOR:

3IB00016*ID 094 2008-12-01 To: 2008-12-31 CCB125 PSKowalski AL Chlorination/Bromination PARAMETER Duration PARAMETER 78739 CODE UNITS 6655 FREQUENCY When Disch.

SAMPLING TYPE Total 2008-12-01 2008-12-02 2008-12-03 2008-12-04 2008-12-05 2008-12-06 2008-12-07 2008-12-08 2008-12-09 2008-12-10 2008-12-11 2008-12-12 2008-12-13 2008-12-14 2008-12-15 2008-12-16 2008-12-17 2008-12-18 2008-12-19 2008-12-20 2008-12-21 2008-12-22 2008-12-23 2008-12-24 2008-12-25 2008-12-26 2008-12-27 2008-12-28 2008-12-29 2008-12-30 2008-12-31

_Nametiltle os Responsible I certify under the penalty of law that I have personally examined and am tamilliar Signature of Date (*N¢*YivJii/y I)

Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility of P 1i/rlea fine and imprisonment.

1>'

When completed mail this report to: EDMR Administrator, EDMR Administrator,,, OH, Page4 Ia https ://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f...

1/7/2009

p.ge ;7 Of 40-Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:

LOCATION:

COUNTY:

DISTRICT:

FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:

STATION CODE:

MONITORING PERIOD:

REPORTING LAB:

ANALYST:

NO DISCHARGE INDICATOR:

3IB00016*ID 601 2008-12-01 To: 2008-12-31 CCB 125 PSKowalski AL PARAMETER Flow Rate pH Total Suspended Oil and Grease, Solids Total PARAMETER CODE 50050 00400 00530 00550 UNITS 4108 6653 4106 4106 FREQUENCY Continuous 1 / 2 Weeks 1 / 2 Weeks 1 / 2 Weeks SAMPLING TYPE 24hr Total Grab Grab Grab 2008-12-01 2008-12-02 2008-12-03 2008-12-04 2008-12-05 2008-12-06 2008-12-07 2008-12-08 2008-12-09 2008-12-10 2008-12-11 2008-12-12 2008-12-13 2008-12-14 2008-12-15 2008-12-16 2008-12-17 2008-12-18 2008-12-19 2008-12-20 2008-12-21 2008-12-22 2008-12-23 2008-12-24 2008-12-25 2008-12-26 2008-12-27 2008-12-28 2008-12-29 2008-12-30 2008-12-31 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DD/YY)

Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility of

,Z-2 I V fine and imprisonment.

(/

/

When completed mail this report to: EDMR Administrator, EDMR Administrator,.,

OH, Page

/

https ://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType~viewWithXslt&f...

1/7/2009

-Page 8 of 10-Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:

LOCATION:

COUNTY:

DISTRICT:

FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:

3IB00016*ID STATION CODE:

602 MONITORING PERIOD:

2008-12-01 To: 2008-12-31 REPORTING LAB:

CCB 125 ANALYST:

PSKowalski

-NO DISCHARGE INDICATOR:

AL I

Total Suspended Oil and Grease, Iron, Total Copper, Total PARAMETER Flow Rate pH Solids Total Recoverable Recoverable PARAMETER CODE 50050 00400 00530 00550 00980 01119 UNITS 4108 6653 4106 4106 4107 4107 FREQUENCY Continuous 1/ 2 Weeks 1 / 2 Weeks 1/ 2 Weeks I / 2 Weeks 1 / 2 Weeks SAMPLING TYPE 24hr Total Grab 24hr Composite Grab 24hr Composite 24hr Composite 2008-12-01 2008-12-02 2008-12-03 2008-12-04 2008-12-05 2008-12-06 2008-12-07 2008-12-08 2008-12-09 2008-12-10 2008-12-11 2008-12-12 2008-12-13 2008-12-14 2008-12-15 2008-12-16 2008-12-17 2008-12-18 2008-12-19 2008-12-20 2008-12-21 2008-12-22 2008-12-23 2008-12-24 2008-12-25 2008-12-26 2008-12-27 2008-12-28 2008-12-29 2008-12-30 2008-12-31 Name/Title of Responsible I certify under the penalty of law that I have personally examined and am familiar Signature of Date (MM/DD/YY)

Official or Authorized with the information submitted herein and based on my inquiry of those Responsible Official o Representative individuals immediately responsible for obtaining the information, I believe the Authorized submitted information is true, accurate and complete. I am aware that there are Representative F)

M 1[)C*

),

significant penalties for submitting false information, including the possibility ofni m-When completed mail this report to: EDMR Administrator, EDMR Administrator,,, OH,

/

Page 6 https ://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f...

1/7/2009

-Page 9 of 4 0--

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:

LOCATION:

COUNTY:

DISTRICT:

FirstEnergy Perry Nuclear Power Plt 10 Center Rd North Perry, 44081 Lake NEDO PERMIT NUMBER:

STATION CODE:

MONITORING PERIOD:

REPORTING LAB:

ANALYST:

NO DISCHARGE INDICATOR:

3IBOOO16*ID 800 2008-12-01 To: 2008-12-31 CCB125 PSKowaslki Water Zinc, Total Copper, Total Temperature Recoverable Recoverable PARAMETER CODE 00011 01094 01119 UNITS 4103 4107 4107 FREQUENCY I/Day I/Month I/Month SAMPLING TYPE Continuous Grab Grab 2008-12-01 39.

2008-12-02 38 2008-12-03 37 2008-12-04 37 2008-12-05 38 2008-12-06 38 2008-12-07 37 2008-12-08 35 31 3

2008-12-09 35 2008-12-10 37 2008-12-11 36 2008-12-12 36 2008-12-13 36 2008-12-14 35 2008-12-15 36 2008-12-16 36 2008-12-17 36 2008-12-18 36 2008-12-19 35 2008-12-20 34 2008-12-21 34 2008-12-22 33 2008-12-23 31 2008-12-24 32 2008-12-25 32 2008-12-26 32 2008-12-27 32 2008-12-28 34 2008-12-29 36 2008-12-30 34 2008-12-31 34 N'ame/ i te o0 Responsible I certify under te penalty of law that I nave personally examined and am tamiliar aignature o0 Date t1vtiYIWPt r I)

Official or Authorized

  • ith the information submitted herein and based on my inquiry of those Responsible Official or Representative individuals immediately responsible for obtaining the information, I believe the

. Authorized submitted information is true, accurate and complete. I am aware that there are Representative significant penalties for submitting false information, including the possibility of P O ff fine and imprisonment.

lto When completed mail this report to: EDMR Administrator, EDMR Administrator,,, 01-1, Page C1 https H//ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f..

1/7/2009

Page+ 19of 4.-

Ohio EPA - Daily Discharge Monitoring Report - Form 4500 FACILITY:

LOCATION:

FirstEnergy Perry Nuclear Power Pit 10 Center Rd North Perry, 44081 PERMIT NUMBER:

  • 3IB00016*ID MONITORING PERIOD:

2008-12-01 To: 2008-12-31 PARAMETER COMMENTS:

Station Code Parameter Name Parameter Code Date Unit Comment 004 Oxidants, Total Residual 34044 2008-12-01 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-02 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-03 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-04 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-05 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-06 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-07 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-08 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-09 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-10 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-11 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-12 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-13 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-14 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-15 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-16 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-17 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-18 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-19 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-20 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-21 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-22 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-23 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-24 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-25 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-26 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-27 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-28 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-29 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-30 4106 No bromination event this date 004 Oxidants, Total Residual 34044 2008-12-31 4106 No bromination event this date https://ebiz.epa.ohio.gov/edwr.web/page/report/viewWithXslt.do?actType=viewWithXslt&f...

1/7/2009