ML090370920

From kanterella
Jump to navigation Jump to search
PT Curve Acceptability of Monticello Data for Benchmarking
ML090370920
Person / Time
Site: Pilgrim
Issue date: 01/27/2009
From: Benjamin Parks
NRC/NRR/DSS/SRXB
To: James Kim
Division of Operating Reactor Licensing
kim J, NRR/ADRO/DORL, 415-4125
References
Download: ML090370920 (2)


Text

From:

Benjamin Parks Sent:

Tuesday, January 27, 2009 8:33 AM To:

James Kim

Subject:

RE: Pilgrim PT Curve Jim-I was concerned that the PT amendment would come in with less than a year to review. I keep forgetting that the current limits don't expire until 2010. Noting that, I don't have any other questions.

I did not identify any issues with the Monticello data that would preclude their acceptability for Pilgrim benchmarking.

Thanks, Ben From: James Kim Sent: Tuesday, January 27, 2009 8:19 AM To: Benjamin Parks

Subject:

Pilgrim PT Curve

Ben, The current PT curves for Pilgrim expires on June 8, 2010. And the Pilgrim has to submit the PT curve amendment to NRC by June 8, 2009.

Thanks Jim Kim E-mail Properties Mail Envelope Properties (DC2088DF7F51A8499309AA4A35D0C1E01C6B69EED3)

Subject:

RE: Pilgrim PT Curve Sent Date: 01/27/2009 8:33:05 AM Received Date: 01/27/2009 8:33:05 AM From: Benjamin Parks Created By: Benjamin.Parks@nrc.gov Recipients:

James.Kim@nrc.gov (James Kim)

Tracking Status: None Post Office:

HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 11509 01/27/2009

Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: