10 CFR Part 21 Reporting Thread Sealant Issue
ML082840384
Person / Time
Site: Watts Bar, Callaway, Farley  
Issue date: 10/03/2008
From: King T
Namco Controls
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML082840384 (11)


Text

NAMCO Controls 2013 West Meeting Street EZ M=

Lancaster, SC 29720-8842 U

WE?

7 US Nuclear Regulatory Commission October 3, 2008 Document Control Desk Washington, DC 20555

Subject:

10CFR Part 21 Reporting Thread sealant Issue The enclosed reports address a reportable notification for thread sealant.supplied by Namco to TVA - Watts Bar Nuclear Plant, Dominion Nuclear Connecticut, Ameren-Callaway Plant, Alabama Power - Farley Nuclear Plant, New Brunswick - Point Lepreau Gen. Station.

A copy of the report has also been sent to each of the affected users, TVA - Watts Bar Nuclear Plant, Dominion Nuclear Connecticut, Ameren-Callaway Plant, Alabama Power -

Farley Nuclear Plant, New Brunswick - Point Lepreau Gen. Station.

On September 19, 2008, Namco determined that it had shipped product that did not meet the customer purchase order requirements. Namco supplied clear thread sealant instead of white thread sealant. The thread sealants are the same except that the white has an additional pigmentation additive.. Namco began an evaluation and on September 29, 2008, determined that it did not have the capability to determine the impact to the supplied users. Therefore in accordance with 10CFR Part 21, Namco provided notification.

Namco has reviewed previous purchase orders of thread sealant and determined that these are the only affected customers.

Regards.

Vice President/General Manager 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289-1361 r2All4 Page 1

NAMCO Controls 2013 West Meeting Street.-

A.,

M Lancaster, SC 29720-8842 N I Wi NW4W Namco Information Notice: 2008-01 October 3, 2008

Subject:

Namco Order 76058 for Ameren - Callaway Plant From:c*

/y Tony King Vice President/General Manager 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289-1361 Items Affected By This Information Notice:

Thread sealant provided under Namco order number 76058 (Ameren.PO 383106 SR).

The thread sealant is identified by Namco part number EH459-20000, lot 411920 (Ameren part number 7649033).

Purpose:

The purpose of this Namco Information Notice.is to alert Ameren that as of September 19,

.2008, Namco became aware of the possibility of a.situation which may impact the performance of your equipment. Namco began an evaluation and determined on September 29, 2008, that it did not have the capability to. determine the impact to your organization.

We are informing you of this circumstance in accordance with'21.21 (b) of 10CFR21.

Applicability:

This notice applies only to the thread sealant mentioned above supplied by Namco under Ameren PO 383106 SR. Namco Qualification Test Report (Qtr1 26) requires white thread

.sealant and Ameren PO 383106 SR requires material in accordance with Qtr 126.

Discussion:

Namco has determined thatthe material provided did not meet the requirements of Ameren PO 383106 SR.

Specifically the discrepancies are:

1. Clear thread sealant was provided instead of white thread sealant.

Per statement from Namco engineering, the materials are the same except that the white material has an additional pigmentation additive.

Page 1

Corrective Action Namco commercially grade dedicates this material through material testing at a third party.

The color check has been added to the material test specifications. All material tests are reviewed by quality personnel as part of the acceptance plan.

Action Required Contact.Namco Customer. Service at 1-800-476-6952 to obtain an RMA number for return and replacement of the material.

10CFR21 Implications Namco requests that the recipient of this notice review it and take appropriate action in accordance with 10CFR21.

If there are any questions or concerns, please contact:

Ken Gould Quality Manager Namco Controls 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289 -1362 Fax: (803) 289 -1367 Page2

NAMCO Controls 2013 West Meeting Street Lancaster, SC 29720-8842 WE MW' W

Namco Information Notice: 2008-01 October 3, 2008

Subject:

Namco Order 76054 for Alabama Power - Farley Nuclear Plant From:

Tony King Vice President/General Manager 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289 - 1361 Items Affected By This Information Notice:

Thread sealant provided under Namco order number 76054 (Alabama Power PO QP080620). The thread sealant is identified by Namco part number EC212-10102, lot 411922 (Alabama Power part number 0000000044447F).

Purpose:

The purpose of this Namco Information Notice is to alert Alabama Power that as of September 19, 2008, Namco became aware of the possibility of a situation which may impact the performance of your equipment. Namco began an evaluation and determined on September 29, 2008, that it did not have the capability to determine the impact to your organization.

We are informing-you of this circumstance in accordance with 21.21 (b) of 10CFR21.

Applicability:

This notice applies only to the thread sealant mentioned above supplied by Namco under Alabama Power PO QP080620. Namco Qualification Test Report (Qtr142) requires white thread sealant and Alabama Power PO QP080620 requires material in accordance with Qtr 142.'

Discussion:

Namco has determined that the material provided did not meet the requirements of Alabama Power PO QP080620.

Specifically the discrepancies are:

1. Clear thread sealant was provided instead of white thread sealant.

Per statement from Namco engineering, the materials are the same except that the white

.material has an additional pigmentation additive.

Page I

Corrective Action Namco commercially grade dedicates this material through material testing at a third party.

The color check has been added to the material test specifications. All material tests are reviewed by quality personnel as part of the acceptance plan.

Action Required Contact Namco Customer Service at 1-800-476-6952 to obtain an RMA number for return and replacement of the material.

10CFR21 Implications Namco requests that the recipient of this notice review it and take appropriate action in.

accordance with 10CFR21.

If there are any questions or concerns, please contact:

Ken Gould Quality Manager Namco Controls 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289 - 1362 Fax: (803) 289-1367 Page2

NAMCO Controls 2013 West Meeting Street,-

=M w A Lancaster, SC 29720-8842 AN wM 'HW 1W Namco Information Notice: 2008-01 October 3, 2008

Subject:

Namco Order 76510 for Dominion - Connecticut From:

Tony King Vice President/General Manager 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289-1361 Items Affected By This Information Notice:

Thread sealant provided under Namco order number 76510 (Dominion PO 45616361).

The thread sealant is identified by Namco part number EH459-20000, lot 412005 (Dominion part number M2940101).

Purpose:

The purpose of this Namco Information Notice is to alert Dominion that as of September 19, 2008, Namco became aware of the possibility of a situation which may impact the performance of your equipment. Namco began an evaluation and determined on September 29, 2008, that it did not have the capability to determine the impact to your organization.

We are informing you of this circumstance in accordance with 21.21 (b) of 1.OCFR21.

Applicability:

This notice applies only to the thread sealant mentioned above supplied by Namco under Dominion P04561:6361. Namco Qualification Test Report (Qtr126) requires white thread sealant and Dominion PO 45616361 requires material in accordance with Qtr 126.

Discussion:

Namco. has determined that the material provided did not meet the requirements of Dominion PO 45616361.

Specifically the discrepancies are:

1. Clear thread sealant was provided instead of white thread sealant.

Per statement from Namco engineering, the materials are the same except that the white material has an additional pigmentation additive.

Page 1

Corrective Action Namco commercially grade dedicates this material through material testing at a third party.

The color check has been added to the material test specifications. All material tests are reviewed by quality personnel as part of the acceptance plan.

Action Required Contact Namco Customer Service at 1-800-476-6952 to obtain an RMA number for return and replacement of the material.

10CFR21 Implications Namco requests that the recipient of this notice review it and take appropriate action in accordance with 10CFR21.

If there are any questions or concerns, please contact:

Ken Gould Quality Manager Namco Controls 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289 - 1362 Fax: (803) 289-1367 Page2

NAMCO Controls 2013 West Meeting Street

=,,,

-==

i n

Lancaster, SC 29720-8842 N

WE NW MW Namco Information Notice: 2008-01 October 3, 2008

Subject:

Namco Order,75509 for TVA - Watts Bar Nuclear Plant From:

Tony King Vice President/General Manager 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289 - 1361 Items Affected By This Information Notice:

Thread sealant provided under Namco order number 75509.(TVA PO 00070953). The thread sealant is identified by Namco part number EH459-20000, lot 411838 (TVA part number BVG814N).

Purpose:

The purpose of this Namco Information Notice is to alert TVA'that as of September 19, 2008, Namco became aware of the possibility of a situation which may impact the performance of your equipment. Namco began an evaluation and determined on September 29, 2008, that it did not have the capability to determine the impact to your organization.

We are informing you of this circumstance in accordance with 21.21 (b) of.10CFR21.

Applicability:

This notice applies only to the thread sealant mentioned above supplied -by Namco under TVA PO 00070953. Namco Qualification Test Report (Qtr126) requires white thread sealant and TVA P0 00070953 requires material-in accordance -with Qtr 126.

Discussion:

Namco has determined that the material provided did not meet the requirements of WVA PO 00070953.

Specifically the discrepancies are:

1. Clear thread sealant was provided instead of white thread sealant.

Per statement from Namco engineering, the materials are the same except that the white material has an additional pigmentation additive.

Page I

Corrective Action Namco commercially grade dedicates this material through material testing at a third party.

The color check has been added to the material test specifications. All material tests are reviewed by quality personnel as part of the acceptance plan.

Action Required Contact Namco Customer Service at 1-800-476-6952 to obtain an RMA number for return and replacement of the material.

10CFR21 Implications Namco requests that the recipient of this notice review it and take appropriate action in accordance with 10CFR21.

If there are any questions or concerns, please contact:

Ken Gould Quality Manager Namco Controls 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289 -1362 Fax: (803) 289-1367 Page2

NAMCO Controls 2013 West Meeting Street

="m

  • WMf=

-M AV Lancaster, SC 29720-8842 N IEWMi EN 1W *W Namco Information Notice: 2008-01 October 3, 2008

Subject:

Namco Order 74743 for New Brunswick - Point Lepreau From:

Tony King Vice President/General Manager Danaher Controls 2013.W. Meeting Street Lancaster, SC 29720 Phone: (803) 289 - 1361 Items Affected By This Information Notice:

Thread sealant provided under Namco order number 74743 (New Brunswick PO 4500296643). The thread sealant is identified by Namco part number EC212-10102, lot 411718 (New Brunswick part number 7421796W).

Purpose:

The purpose of this Namco Information Notice is to alert New Brunswick that as of September 19, 2008, Namco became aware of the possibility of-a situation which may impact the performance of your equipment. Namco began an evaluation and determined on September 29, 2008, that it did not have the capability to determine the impact to your organization.

We are informing you of this circumstance in accordance with21.21 (b) of 10CFR21.

Applicability:

This notice applies only to the thread sealant mentioned above supplied by Namco under New Brunswick PO 4500296643. Namco Qualification Test Report (Qtri42) requires white thread sealant and New Brunswick PO 4500296643 requires material in accordance with Qtr 142.

Discussion:

Namco has determined that the material provided did not meet the requirements of New Brunswick PO 4500296643.

Specifically the discrepancies are:

1. Clear thread sealant was provided instead of white thread sealant.

Per statement from Namco engineering, the materials are the same except that the white material -has-an-additional-pigmentation additive..

Page l

Corrective Action Namco commercially grade dedicates this material through material testing at a third party.

The color check has been added to the material test specifications. All material tests are reviewed by quality personnel as part of the acceptance plan.

Action Required Contact Namco Customer Service at 1-800-476-6952 to obtain an RMA number for return and replacement of.the material.

10CFR21 Implications Namco requests that the recipient of this notice review it and take appropriate action in accordance with 10CFR21.

If there are any questions or concerns, please contact:

Ken Gould Quality Manager Namco Controls 2013 W. Meeting Street Lancaster, SC 29720 Phone: (803) 289 - 1362 Fax;.(803) 289-1367 Page2