ES-401 Grand Gulf Written Examination Form ES-401-9 Review Worksheet (password: ) (TAC#: )
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other Q#
- 1.
LOK (F/H)
- 2.
LOD (1-5)
Stem Focus Cu es T/F Cred.
Dist.
Partia l
Job-Link Minuti a
- /
units Back-ward Q=
K/A SRO Only
- 6.
U/E/S
- 7.
Explanation 1N F
2 U
U S
A, CR, 43.10. This is a KA mismatch because the question is not focused on the ability to make reports.
This question was rewritten.
2N F
3 S
D, CR, 43.7.
3N F
2 S
A, CR, 43.10.
4N F
2 S
B, CR, 43.10.
5B H
3 S
A, OR, 43.10.
6N H
2 S
D, OR, 43.12.
7B F
1 U
U S
D, OR, 43.12. This is a direct lookup.
After discussion with the facility, it was determined this is not a direct lookup.
8N F
4 E
E S
D, CR, 43.10. This question is E because it tests on subsequent actions in an AOP is this is not typically considered a memory item.
This question is considered as required knowledge by the facility.
9N F
3 S
C, CR, 43.10.
Instructions
[Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts.]
- 1.
Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.
- 2.
Enter the level of difficulty (LOD) of each question using a 1 - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).
- 3.
Check the appropriate box if a psychometric flaw is identified:
The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).
The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).
The answer choices are a collection of unrelated true/false statements.
One or more distractors is (are) not credible.
One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).
- 4.
Check the appropriate box if a job content error is identified:
The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).
The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).
The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).
The question requires reverse logic or application compared to the job requirements.
- 5.
Check questions that are sampled for conformance with the approved K/A and those that are designated SRO-only (K/A and license level mismatches
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other Q#
- 1.
LOK (F/H)
- 2.
LOD (1-5)
Stem Focus Cu es T/F Cred.
Dist.
Partia l
Job-Link Minuti a
- /
units Back-ward Q=
K/A SRO Only
- 6.
U/E/S
- 7.
Explanation are unacceptable).
- 6.
Based on the reviewer=s judgment, is the question as written (U)nacceptable (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?
- 7.
At a minimum, explain any AU@ ratings (e.g., how the Appendix B psychometric attributes are not being met).
33 of 34 NUREG-1021, Draft Revision 9
ES-401 2
Form ES-401-9
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other Q#
- 1.
LOK (F/H
)
- 2.
LOD (1-5)
Stem Focus Cues T/F Cred Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only
- 6.
U/E/S
- 7.
Explanation 10N F
3 U
U S
D, CR, 43.10. This is a backward logic question - it asks what not to do instead of what is required to be done.
This question was rewritten.
11B H
2 S
A, CR, 43.2.
12N H
2 S
D, CR, 43.7.
13B H
3 S
A, CR, 43.4.
14N H
3 S
A, CR, 43.2.
15N F
3 S
D, CR, 43.7.
16N H
3 S
D, CR, 43.7.
17N F
2 S
D, CR, 43.7.
18N H
3 S
B, CR, 43.7.
19N H
3 S
A, CR, 43.6 20N H
3 S
C, CR, 43.2.
21N F
3 S
B, CR, 43.10.
22B H
3 S
C, CR, 43.6.
23N F
3 S
C, CR, 43.5.
24N H
4 S
C, CR, 43.7.
25N H
4 S
B, CR, 43.7.
26N H
3 S
D, CR, 43.7.
27N H
3 S
B, CR, 43.7.
28N F
3 S
B, CR, 43.7.
29N H
3 S
D, CR, 43.7.
30N H
2 S
B, CR, 43.7.
31N H
3 S
C, CR, 43.7.
32N H
3 S
B, CR, 43.10.
33N H
3 S
C, CR, 43.10.
34N H
3 S
D, CR, 43.10.
35N F
3 S
B, CR, 43.4.
36N H
3 S
B, CR, 43.4.
37N H
3 S
B, CR, 43.7.
38N F
3 S
C, CR, 43.7.
39N F
2 S
A, CR, 43.10.
40N H
3 S
A, CR, 43.7.
41B H
2 S
C, CR, 43.7. This question was submitted as a modified question but was counted as a bank since the modified bank question was not submitted.
42N F
3 S
C, CR, 43.4.
43M H
3 S
A, CR, 43.7.
44N F
3 S
B, CR, 43.2.
45N F
3 E
S C, CR, 43.7. This question is E because the reference provided is the TS basis technically making it an SRO question. Recommend the system training materials be provided stating the function(s) of the system.
This question was revised.
46N F
3 U
U S
A, OR, 43.10. This question is U because it is a direct lookup. Recommend making this a closed reference question since it is testing on an ONP immediate action.
This question is not a direct lookup in that the only reference provided is the power to flow map and the question asks for immediate actions.
47N H
2 S
D, CR, 43.7.
48N F
2 S
D, CR, 43.7.
ES-401 2
Form ES-401-9
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other Q#
- 1.
LOK (F/H
)
- 2.
LOD (1-5)
Stem Focus Cues T/F Cred.
Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only
- 6.
U/E/S
- 7.
Explanation 49N H
3 S
A, CR, 43.4.
50N H
3 S
C, CR, 43.7.
51N F
2 S
C, NRef, 43 52B H
2 S
B,NR,43 53N H
2 S
C,NR, 43 54N H
3 S
B,NR, 43 55N F
2 S
A,NR,43 56B F
2 S
C,NR,43 57B H
2 S
A,NR,43 58N F
2 S
C,NR,43 59N F
2 E
S D, add maximum before press. In A This question was revised.
60N H
2 x
U S
d is not credible This question was left as is.
61N H
2 S
D, NR, 43.5 62N F
2 S
A,NR, 43.5 63N H
2 x
E S
A, Energizing alone; reset has to occur 43.5 This question is ok as written.
64N F
2 S
D, NR, 43 65N F
2 S
B, NR,43 66N H
2 S
A,NR,43 34 of 34 NUREG-1021, Draft Revision 9
ES-401 2
Form ES-401-9
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other Q#
- 1.
LOK (F/H
)
- 2.
LOD (1-5)
Stem Focus Cues T/F Cred Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only
- 6.
U/E/S
- 7.
Explanation 67N F
2 U
S C&D could be argued the same This question was revised.
68N H
2 S
A,NR, 43 69N H
3 S
A,NR, 43 70N F
3 S
B,NR,43 71N H
3 S
C, NR, 43 72B H
3 S
D, NR,43 73N F
3 S
A,NR,43 74N H
2 S
B,NR,43 75N F
3 S
A,NR,43 76N H
3 S
B,R,43.2 77N H
3 S
D,R,43.2 This question was revised to eliminate the reference and reduce the number of open reference questions.
78N H
3 S
C,R,43.4 79N H
3 S
D,R,43.4 80N H
3 S
D,R,43.2 81N H
3 S
C,R,43.4 82N H
2 S
C,R,43.4 83N F
2 S
A,NR,43.4 84B H
3 S
C,R,43.4 85N H
3 S
B,R,43.5 86N H
3 S
A,R,43.2
87N H
3 S
A,R,43.2 This question was revised to eliminate the reference and reduce the number of open reference questions.
88N H
3 S
B,R,43.4 89N H
3 S
C,R, 43.4 90N H
3 S
B,R,43.2 This question was revised to eliminate the reference and reduce the number of open reference questions.
91N H
3 S
B,R, 43.2 92N F
3 S
A,NR,43.2 93N H
F 2
S C,NR,43.6 This question is fundamental knowledge.
94N H
F 2
S B,NR43.3 This question is fundamental knowledge.
95B H
2 U
S Dir LU;R; 43.2 After discussing with the facility, this not considered a direct lookup question.
96N H
F 3
S D,R,43.2 This question was revised to eliminate the reference and reduce the number of open reference questions.
This question is fundamental knowledge.
97N H
2 S
A; R,43.1 This question was revised to eliminate the reference and reduce the number of open reference questions.
98N F
2 S
B,NR,43.2 99N H
3 S
C,NR,43.2 100N H
2 S
A,R,43.2 This question was revised to eliminate the reference and reduce the number of open reference questions.
RO H= 42 (56%)
U= 5
B=10 M=1 N=64 F= 33 (44%)
M N
H= 20 (80%)
F= 4 (20%)
U= 1 E= 0 SRO TOTALS
GENERAL COMMENT
S:
- 1.
Bank questions are indicated by B; Modified are indicated by M; New questions are indicated by N.
- 2.
Chief Examiner comments are indicated in blue.
- 3.
The facility was directed to reduce the number of open reference questions to 13 on the SRO exam.
34 of 34 NUREG-1021, Draft Revision 9